Spatial Resolution of a microCT Scanner

We have measured the spatial resolution of the 450 kV test-bed microCT scanner. We have also modeled the resolution analytically. The model and measurement show correspondence within 5%. Our measurement method was to use a thin tungsten wire to act as an impulse function. Therefore, the image is the impulse response, also called the point spread function (PSF) of the system. The Fourier transform (FT) of the impulse response is the modulation transfer function (MTF) of the system. We report the MTF here. By moving the wire at different positions in the scan field of view (FOV), we can measure MTF at different positions in the FOV. Since our imaging system is radially symmetric, we report MTF in two directions, radial and tangential as shown in Figure 1. The radial direction is along the line from isocenter to the wire, and the tangential is perpendicular to it.

42 ENGINEERING↗

TU-F-17A-04: Respiratory Phase-Resolved 3D MRI with Isotropic High Spatial Resolution: Determination of the Average Breathing Motion Pattern for Abdominal Radiotherapy Planning

Purpose: To develop a retrospective 4D-MRI technique (respiratory phase-resolved 3D-MRI) for providing an accurate assessment of tumor motion secondary to respiration. Methods: A 3D projection reconstruction (PR) sequence with self-gating (SG) was developed for 4D-MRI on a 3.0T MRI scanner. The respiration-induced shift of the imaging target was recorded by SG signals acquired in the superior-inferior direction every 15 radial projections (i.e. temporal resolution 98 ms). A total of 73000 radial projections obtained in 8-min were retrospectively sorted into 10 time-domain evenly distributed respiratory phases based on the SG information. Ten 3D image sets were then reconstructed offline. The technique was validated on a motion phantom (gadolinium-doped water-filled box, frequency of 10 and 18 cycles/min) and humans (4 healthy and 2 patients with liver tumors). Imaging protocol included 8-min 4D-MRI followed by 1-min 2D-realtime (498 ms/frame) MRI as a reference. Results: The multiphase 3D image sets with isotropic high spatial resolution (1.56 mm) permits flexible image reformatting and visualization. No intra-phase motion-induced blurring was observed. Comparing to 2D-realtime, 4D-MRI yielded similar motion range (phantom: 10.46 vs. 11.27 mm; healthy subject: 25.20 vs. 17.9 mm; patient: 11.38 vs. 9.30 mm), reasonable displacement difference averaged over the 10 phases (0.74mm; 3.63mm; 1.65mm), and excellent cross-correlation (0.98; 0.96; 0.94) between the two displacement series. Conclusion: Our preliminary study has demonstrated that the 4D-MRI technique can provide high-quality respiratory phase-resolved 3D images that feature: a) isotropic high spatial resolution, b) a fixed scan time of 8 minutes, c) an accurate estimate of average motion pattern, and d) minimal intra-phase motion artifact. This approach has the potential to become a viable alternative solution to assess the impact of breathing on tumor motion and determine appropriate treatment margins. Comparison with 4D-CT in a clinical setting is warranted to assess the value of 4D-MRI in radiotherapy planning. This work supported in part by grant 1R03CA173273-01.

60 APPLIED LIFE SCIENCES↗

Theoretical limit of spatial resolution in diffuse optical tomography using a perturbation model

We have assessed the limit of spatial resolution of timedomain diffuse optical tomography (DOT) based on a perturbation reconstruction model. From the viewpoint of the structure reconstruction accuracy, three different approaches to solving the inverse DOT problem are compared. The first approach involves reconstruction of diffuse tomograms from straight lines, the second – from average curvilinear trajectories of photons and the third – from total banana-shaped distributions of photon trajectories. In order to obtain estimates of resolution, we have derived analytical expressions for the point spread function and modulation transfer function, as well as have performed a numerical experiment on reconstruction of rectangular scattering objects with circular absorbing inhomogeneities. It is shown that in passing from reconstruction from straight lines to reconstruction using distributions of photon trajectories we can improve resolution by almost an order of magnitude and exceed the accuracy of reconstruction of multi-step algorithms used in DOT. (optical tomography)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Nm-scale spatial resolution x-ray imaging with MLL nanofocusing optics: instrumentational requirements and challenges

The Hard X-ray Nanoprobe (HXN) beamline at NSLS-II has been designed and constructed to enable imaging experiments with unprecedented spatial resolution and detection sensitivity. The HXN X-ray Microscope is a key instrument for the beamline, providing a suite of experimental capabilities which includes scanning fluorescence, diffraction, differential phase contrast and ptychography utilizing Multilayer Laue Lenses (MLL) and zoneplate (ZP) as nanofocusing optics. In this paper, we present technical requirements for the MLL-based scanning microscope, outline the development concept and present first ~15 x 15 nm 2 spatial resolution x-ray fluorescence images.

47 OTHER INSTRUMENTATION↗

Spiers Memorial Lecture : Surface-enhanced Raman spectroscopy: from single particle/molecule spectroscopy to ångstrom-scale spatial resolution and femtosecond time resolution

Four decades on, surface-enhanced Raman spectroscopy (SERS) continues to be a vibrant field of research that is growing (approximately) exponentially in scope and applicability while pushing at the ultimate limits of sensitivity, spatial resolution, and time resolution. This introductory paper discusses some aspects related to all four of the themes for this Faraday Discussion. First, the wavelength-scanned SERS excitation spectroscopy (WS-SERES) of single nanosphere oligomers ( viz. , dimers, trimers, etc. ), the distance dependence of SERS, the magnitude of the chemical enhancement mechanism, and the progress toward developing surface-enhanced femtosecond stimulated Raman spectroscopy (SE-FSRS) are discussed. Second, our efforts to develop a continuous, minimally invasive, in vivo glucose sensor based on SERS are highlighted. Third, some aspects of our recent work in single molecule SERS and the translation of that effort to ångstrom-scale spatial resolution in ultrahigh vacuum tip-enhanced Raman spectroscopy (UHV-TERS) and single molecule electrochemistry using electrochemical (EC)-TERS will be presented. Finally, we provide an overview of analytical SERS with our viewpoints on SERS substrates, approaches to address the analyte generality problem ( i.e. target molecules that do not spontaneously adsorb and/or have Raman cross sections <10 -29 cm 2 sr -1 ), SERS for catalysis, and deep UV-SERS.

Chemistry↗

Spectroscopy-based isotopic (δ 13 C) analysis for high spatial resolution of carbon exchange in the rhizosphere

The rhizosphere is a highly dynamic zone bridging plant roots with needed nutrient resources in soil. While the rhizosphere may be small, it has a disproportionally large impact on plant success and biomass production. A suite of rhizosphere-hosted microbial and geochemical interactions facilitate nutrient acquisition by plant roots, and, in turn, the roots stimulate these processes by supplying organic carbon into the rhizosphere. The small physical dimensions of the rhizosphere, however, can constrain efforts to elucidate key carbon exchange processes and their spatial extent and localization. We present a method for spatially resolved δ 13 C analysis of rhizosphere samples by coupling laser ablation (LA) sampling with isotopic analysis using capillary absorption spectroscopy (CAS) which differs from conventional mass spectrometer (MS) approaches. The CAS system has high sensitivity (requires fewer nanomoles of CO 2 per analysis) than comparable MS systems, which enables reduced sample size requirements to thereby improve spatial resolution (from 25 μm to as low as a projected 5 μm spatial resolution). We demonstrate the utility of CAS using rhizosphere samples from switchgrass plants exposed to 13 CO 2 . As a result, this technique will provide a capability for tracking the extent and spatial distribution of root exudate into the rhizosphere at highly detailed spatial scales.

59 BASIC BIOLOGICAL SCIENCES↗

Mapping Molecular Adsorption Configurations with < 5 nm Spatial Resolution through Ambient Tip-Enhanced Raman Imaging

We interrogate para-mercaptobenzoic acid (MBA) molecules chemisorbed onto plasmonic silver nanocubes through tip-enhanced Raman (TER) spectral nano-imaging. Through a detailed examination of the spectra, aided by correlation analysis and density functional theory calculations, we find that MBA chemisorbs onto the plasmonic particles with at least two distinct configurations: S- and CO2-bound. High spatial resolution TER mapping allows us to distinguish between the distinct adsorption geometries with a pixel-limited (< 5 nm) spatial resolution under ambient laboratory conditions.

Gabel, Matthew L.↗

Enhanced spatial resolution of Eljen-204 plastic scintillators for use in rep-rated proton diagnostics

A pixelated scintillator has been designed, fabricated, and tested using a laser-accelerated proton source for use in proton diagnostics at rep-rated laser facilities. The work presented here demonstrates the enhanced spatial resolution of thin, organic scintillators through a novel pixelation technique. Furthermore, experimental measurements using laser-generated protons incident onto 130 μm-thick scintillators indicate a >20% reduction in the scintillator point spread function (PSF) for the detectors tested. The best performing pixelated detector reduced the ~200 μm PSF of the stock material to ~150 μm. The fabrication technique may be tailored to reduce the pixel size and achieve higher spatial resolutions.

47 OTHER INSTRUMENTATION↗

Real space soft x-ray imaging at 10 nm spatial resolution

Using Fresnel zone plates made with our robust nanofabrication processes, we have successfully achieved 10 nm spatial resolution with soft x-ray microscopy. The result, obtained with both a conventional full-field and scanning soft x-ray microscope, marks a significant step forward in extending the microscopy to truly nanoscale studies.

36 MATERIALS SCIENCE↗

Ambient Single-Cell Analysis and Native Tissue Imaging Using Laser-Ablation Electrospray Ionization Mass Spectrometry with Increased Spatial Resolution

Laser ablation electrospray ionization mass spectrometry (LAESI-MS) is an emerging method that has the potential to transform the field of metabolomics. This is in part due to LAESI-MS being an ambient ionization method that requires minimal sample preparation and uses (endogenous) water for in situ analysis. This application note details the employment of the ‘LAESI microscope’ source to perform spatially resolved MS analysis of cells and MS imaging (MSI) of tissues at high spatial resolution. This source configuration utilizes a long-working distance reflective objective that permits both visualization of the sample and a smaller LAESI laser beam profile than conventional LAESI setups. In this work, we analyzed 200 single cells of Allium cepa (red onion) and imaged Fittonia argyroneura (nerve plant) in high spatial resolution using this source coupled to a Fourier transform mass spectrometer for high mass resolution and high mass accuracy metabolomics.

59 BASIC BIOLOGICAL SCIENCES↗

Direct Modeling of Scintillator Thickness for Optimal Light Output and Spatial Resolution

It is common in x-ray radiography to use scintillators (e.g., BGO or LSO) to convert x-rays to visible light, which is then recorded by an imaging system. The response of the scintillator depends fundamentally on its thickness, with respect to both its visible light emittance and its spatial resolution. This is important for optimizing light output, signal to noise ratio, or optical response time. Given that it is often cost-prohibitive to procure a variety of scintillator samples and empirically test the performance, it is essential to be able to model and accurately simulate the performance of a scintillator with respect to thickness and other properties, and a direct way of doing this is using Monte Carlo-based radiation transport codes. Such simulations can be expensive in terms of computational time, and the codes are not easily obtained. In this work we first show such simulations, and demonstrate that there is a natural trade-off between light output of a scintillator and its spatial resolution. We then derive a first-principles model that accurately approximates the light output, using straightforward calculations that can be performed quickly with any basic computing software. We compare the results to those obtained from Monte Carlo simulations and show that our simplified model can be used to analyze the tradeoff between emittance and resolution nearly as well as using a full-scale radiation transport code.

Monte Carlo methods, X-ray imaging, scintillation ↗

Tip-Enhanced Raman Chemical and Chemical Reaction Imaging in H 2 O with Sub-3-nm Spatial Resolution

Reproducible chemical and chemical reaction nano-imaging at solid-liquid interfaces remains challenging, particularly when resolutions on the order of a few nm are sought after. In this work, we demonstrate the latter through liquid tip-enhanced Raman (TER) measurements that target gold nanoplates functionalized with 4-mercaptobenzonitrile (MBN). In addition to chemical imaging and local optical field nano-visualization with high spatial resolution, we observe the signatures of 4-mercaptobenzoic acid, which forms as a result of plasmon-induced hydrolysis of MBN. Evidently, the solvent leads to distinct plasmon-induced/enhanced chemical reaction pathways that have not been documented. Here this work shows that such reactions that take place at solid-liquid interfaces can be tracked with a record sub-3 nm spatial resolution via TER spectral nano-imaging in liquids.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effects of spatial resolution on WRF v3.8.1 simulated meteorology over the central Himalaya

The sensitive ecosystem of the central Himalayan (CH) region, which is experiencing enhanced stress from anthropogenic forcing, requires adequate atmospheric observations and an improved representation of the Himalaya in the models. However, the accuracy of atmospheric models remains limited in this region due to highly complex mountainous topography. This article delineates the effects of spatial resolution on the modeled meteorology and dynamics over the CH by utilizing the Weather Research and Forecasting (WRF) model extensively evaluated against the Ganges Valley Aerosol Experiment (GVAX) observations during the summer monsoon. The WRF simulation is performed over a domain (d01) encompassing northern India at 15 km x 15 km resolution and two nests (d02 at 5 km x 5 km and d03 at 1 km x 1 km) centered over the CH, with boundary conditions from the respective parent domains. WRF simulations reveal higher variability in meteorology, e.g., relative humidity (RH = 70.3%-96.1%) and wind speed (WS = 1.1-4.2m s(-1)), compared to the ERA-Interim reanalysis (RH D 80.0%-85.0%, WS D 1.2-2.3m s(-1)) over northern India owing to the higher resolution. WRF-simulated temporal evolution of meteorological variables is found to agree with balloon-borne measurements, with stronger correlations aloft (r = 0.44-0.92) than those in the lower troposphere (r = 0.18-0.48). The model overestimates temperature (warm bias by 2.8 degrees C) and underestimates RH (dry bias by 6.4 %) at the surface in d01. Model results show a significant improvement in d03 (P = 827.6 hPa, T = 19.8 degrees C, RH = 92.3 %), closer to the GVAX observations (P = 801.4 hPa, T = 19.5 degrees C, RH = 94.7 %). Interpolating the output from the coarser domains (d01, d02) to the altitude of the station reduces the biases in pressure and temperature; however, it suppresses the diurnal variations, highlighting the importance of well-resolved terrain (d03). Temporal variations in near-surface P, T, and RH are also reproduced by WRF in d03 to an extent (r>0:5). A sensitivity simulation incorporating the feedback from the nested domain demonstrates the improvement in simulated P, T, and RH over the CH. Our study shows that the WRF model setup at finer spatial resolution can significantly reduce the biases in simulated meteorology, and such an improved representation of the CH can be adopted through domain feedback into regional-scale simulations. Interestingly, WRF simulates a dominant easterly wind component at 1 km x 1 km resolution (d03), which is missing in the coarse simulations; however, the frequency of southeasterlies remains underestimated. The model simulation implementing a highresolution (3 s) topography input (SRTM) improved the prediction of wind directions; nevertheless, further improvements are required to better reproduce the observed local-scale dynamics over the CH.

Singh, Jaydeep↗

Toward an integrated platform for characterizing laser-driven, isochorically heated plasmas with 1 µm spatial resolution

Warm dense matter is a region of phase space that is of high interest to multiple scientific communities ranging from astrophysics to inertial confinement fusion. Further understanding of the conditions and properties of this complex state of matter necessitates experimental benchmarking of the current theoretical models. We discuss the development of an x-ray radiography platform designed to measure warm dense matter transport properties at large laser facilities such as the OMEGA Laser Facility. Our platform, Fresnel Diffractive Radiography, allows for high spatial resolution imaging of isochorically heated targets, resulting in notable diffractive effects at sharp density gradients that are influenced by transport properties such as thermal conductivity. We discuss initial results, highlighting the capabilities of the platform in measuring diffractive features with micron-level spatial resolution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Solving Drift-flux Model Using High-Resolution Spatial Discretization Scheme

Accurate modeling and simulation of the two-phase flow phenomena are critical to the system and safety analysis of light water reactors. Compared to the more complex two-fluid model, the drift-flux model treats the two phases as a mixture, and thus the models are formulated to consider the conservation laws of the mixture. The relative motion between the two phases is realized by constitutive correlations. Although the drift flux models have limitations in certain applications, they are widely used in many applications due to their simplicity and applicability to a wide range of two-phase flow problems. First-order numerical schemes are widely used in existing codes, which introduces excessive numerical diffusions. The objective of this work is to investigate a high-resolution spatial scheme in the application to solve drift-flux two-phase flow problems. In this study, a high-resolution spatial discretization scheme has been investigated in the application of solving drift-flux two-phase flow problem. The scheme is validated using existing experimental results. Compared to the first order scheme, it demonstrated excellent capability in reducing numerical error. Extended work will focus on the comparison of numerical errors from discretization schemes and model uncertainties. (authors)

42 ENGINEERING↗

Fluorescence-type Monochromatic X-ray Beam-position Monitor with High-spatial Resolution for the NSLS-II Beamlines

We developed a fluorescence-type monochromatic X-ray beam-position monitor (X-BPM) with high-spatial resolution for end-station experiments at the initial project beamlines of the NSLS-II. We designed a ring array of multi-segmented Si PIN-junction photodiodes to use as a position sensor. Further, we integrated a low-noise charge-preamplification HERMES4 ASIC chip into an electronic readout system for photon-counting application. A series of precision measurements to characterize electronically the Si-photodiode sensor and the ASIC chip demonstrated that the inherent noise from the detector system is sufficiently low to meet our stringent requirements. Using a Gaussian beam, we parametrically modeled the optimum working distance to ensure the detector's best performance. Based upon the results from the parametric modeling, prototypes of the next versions of the X-BPM are being developed. In this paper, we describe the methodology for developing the new compact monochromatic X-ray BPM, including its instrumentation, detector modeling, and future plan.

43 PARTICLE ACCELERATORS↗

TH-CD-201-09: High Spatial Resolution Absorbed Dose to Water Measurements Using Optical Calorimetry in Megavoltage External Beam Therapy

Purpose: To develop and implement a high spatial resolution calorimeter methodology to measure absorbed dose to water (ADW) using phase shifts (PSs) of light passing through a water phantom and to compare measurements with theoretical calculations. Methods: Radiation-induced temperature changes were measured using the PSs of a He-Ne laser beam passing through a (10×10×10) cm{sup 3} water phantom. PSs were measured using a Michelson interferometer and recording the time-dependent fringe patterns on a CCD camera. The phantom was positioned at the center of the radiation field. A Varian 21EX was used to deliver 500 MU from a 9 MeV beam using a (6×6) cm{sup 2} cone. A 127cm SSD was used and the PSs were measured at depths ranging from of 1.90cm to 2.10cm in steps of 0.05cm by taking profiles at the corresponding rows across the image. PSs were computed by taking the difference between pre- and post-irradiation image frames and then measuring the amplitude of the resulting image profiles. An amplitude-to-PS calibration curve was generated using a piezoelectric transducer to mechanically induce PSs between 0.05 and 1.50 radians in steps of 0.05 radians. The temperature dependence of the refractive index of water at 632.8nm was used to convert PSs to ADW. Measured results were compared with ADW values calculated using the linac output calibration and commissioning data. Results: Milli-radian resolution in PS measurement was achieved using the described methodology. Measured radiation-induced PSs ranged from 0.10 ± 0.01 to 0.12 ± 0.01 radians at the investigated depths. After converting PSs to ADW, measured and calculated ADW values agreed within the measurement uncertainty. Conclusion: This work shows that interferometer-based calorimetry measurements are capable of achieving sub-millimeter resolution measuring 2D temperature/dose distributions, which are particularly useful for characterizing beams from modalities such as SRS, proton therapy, or microbeams.

60 APPLIED LIFE SCIENCES↗

Compositional Analysis With Atomic Column Spatial Resolution by 5th Order Aberration-corrected Scanning Transmission Electron Microscopy

We show in this article that it is possible to obtain elemental compositional maps and profiles with atomic-column resolution across an In{sub x}Ga{sub 1-x}As multilayer structure from 5th-order aberration-corrected high-angle annular dark-field scanning transmission electron microscopy (HAADF-STEM) images. The compositional profiles obtained from the analysis of HAADF-STEM images describe accurately the distribution of In in the studied multilayer in good agreement with Muraki's segregation model [Muraki, K., Fukatsu, S., Shiraki, Y. & Ito, R. (1992)]. Surface segregation of In atoms during molecular beam epitaxy and its influence on the energy levels in InGaAs/GaAs quantums wells.

36 MATERIALS SCIENCE↗