Estimating Latent Fields in Stochastic Dynamical Systems - A Case Study of COVID-19 in New Mexico
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Digital program has been written to solve the LSOCE problem by using a time-domain formulation. LSOCE problem is defined as that of designing controls for linear time-invariant system which is disturbed by white noise in such a way as to minimize quadratic performance index.
Problem is defined as that of designing controls for linear time invariant system, which is disturbed by white noise, in such a way as to minimize quadratic performance index.
Problem involves design of controls for linear time-invariant system disturbed by white noise. Solution is Kalman filter coupled through set of optimal regulator gains to produce desired control signal. Key to solution is solving matrix Riccati differential equation. LSOCE effectively solves problem for wide range of practical applications. Program is written in FORTRAN IV for batch execution and has been implemented on IBM 360.
Abstract not provided.
Abstract not provided.
The note considers families of stochastic processes indexed by a finite number of alternative parameter values. For general classes of stochastic processes, it is shown that maximum-likelihood estimates converge almost surely to the correct parameter value. This is established by use of a submartingale property of the sequence of maximized-likelihood ratios together with a technique first employed by Wald (1949) in the case of independent identically distributed random variables.
In this paper, we develop an improved multilevel Monte Carlo (MLMC) method for estimating cumulative distribution functions (CDFs) of a quantity of interest, coming from numerical approximation of large-scale stochastic subsurface simulations. Compared with Monte Carlo (MC) methods, that require a significantly large number of high-fidelity model executions to achieve a prescribed accuracy when computing statistical expectations, MLMC methods were originally proposed to significantly reduce the computational cost with the use of multifidelity approximations. The improved performance of the MLMC methods depends strongly on the decay of the variance of the integrand as the level increases. However, the main challenge in estimating CDFs is that the integrand is a discontinuous indicator function whose variance decays slowly. To address this difficult task, we approximate the integrand using a smoothing function that accelerates the decay of the variance. In addition, we design a novel a posteriori optimization strategy to calibrate the smoothing function, so as to balance the computational gain and the approximation error. The combined proposed techniques are integrated into a very general and practical algorithm that can be applied to a wide range of subsurface problems for high-dimensional uncertainty quantification, such as a fine-grid oil reservoir model considered in this effort. The numerical results reveal that with the use of the calibrated smoothing function, the improved MLMC technique significantly reduces the computational complexity compared to the standard MC approach. Finally, we discuss several factors that affect the performance of the MLMC method and provide guidance for effective and efficient usage in practice.
Purpose: A system was developed that automatically calculates the organ and effective dose for individual fluoroscopically-guided procedures using a log of the clinical exposure parameters. Methods: We have previously developed a dose tracking system (DTS) to provide a real-time color-coded 3D- mapping of skin dose. This software produces a log file of all geometry and exposure parameters for every x-ray pulse during a procedure. The data in the log files is input into PCXMC, a Monte Carlo program that calculates organ and effective dose for projections and exposure parameters set by the user. We developed a MATLAB program to read data from the log files produced by the DTS and to automatically generate the definition files in the format used by PCXMC. The processing is done at the end of a procedure after all exposures are completed. Since there are thousands of exposure pulses with various parameters for fluoroscopy, DA and DSA and at various projections, the data for exposures with similar parameters is grouped prior to entry into PCXMC to reduce the number of Monte Carlo calculations that need to be performed. Results: The software developed automatically transfers data from the DTS log file to PCXMC and runs the program for each grouping of exposure pulses. When the dose from all exposure events are calculated, the doses for each organ and all effective doses are summed to obtain procedure totals. For a complicated interventional procedure, the calculations can be completed on a PC without manual intervention in less than 30 minutes depending on the level of data grouping. Conclusion: This system allows organ dose to be calculated for individual procedures for every patient without tedious calculations or data entry so that estimates of stochastic risk can be obtained in addition to the deterministic risk estimate provided by the DTS. Partial support from NIH grant R01EB002873 and Toshiba Medical Systems Corp.
Stochastic compartmental analysis with examples of estimation in pulse labelled system
We have develop a fast method that can capture piecewise smooth functions in high dimensions with high order and low computational cost. This method can be used for both approximation and error estimation of stochastic simulations where the computations can either be guided or come from a legacy database.
Consideration of the autocorrelation function of a zero-mean stationary random process. The techniques are applicable to processes with nonzero mean provided the mean is estimated first and subtracted. Two recursive techniques are proposed, both of which are based on the method of stochastic approximation and assume a functional form for the correlation function that depends on a number of parameters that are recursively estimated from successive records. One technique uses a standard point estimator of the correlation function to provide estimates of the parameters that minimize the mean-square error between the point estimates and the parametric function. The other technique provides estimates of the parameters that maximize a likelihood function relating the parameters of the function to the random process. Examples are presented.
Mobile-to-mobile networks are characterized by node mobility that makes the propagation environment time varying and subject to fading. As a consequence, the statistical characteristics of the received signal vary continuously, giving rise to a Doppler power spectral density (DPSD) which varies from one observation instant to the next. The current models do not capture and track the time varying characteristics. This paper is concerned with dynamical modelling of mobile-to-mobile channels, parameter estimation and identification from received signal measurements. The evolution of the propagation environment is described by stochastic differential equations. In particular, it is shown that the parameters of the models can be determined by approximating the band-limited DPSD using the Gauss-Newton method. However, since the DPSD is not available online, we propose to use a filter-based expectation maximization algorithm and Kalman filter to estimate the channel parameters and states, respectively. The scheme results in a finite dimensional filter which only uses the first and second order statistics. The algorithm is recursive allowing the inphase and quadrature components and parameters to be estimated online from received signal measurements. The algorithms are tested using experimental data collected from moving sensor nodes in indoor and outdoor environments demonstrating the method s viability.
We present a numerical error estimation technique specifically formulated to deal with stochastic code output with multiple discretization parameters. This method is based on multiple fits to an error model with arbitrary convergence rates and cross-coupling terms, performed using nonlinear optimization. The fitting approach varies by the type of residual norm which influences the importance of outliers, and weights which influences the relative importance of data points in the coarse and refined regions of discretization parameter space. To account for the influence of stochastic noise, these fits are performed on multiple bootstrap values based on the underlying response data set. Using an automated discretization domain selection scheme, the fits are performed on a series of reduced sets of discretization levels in order to find an optimal fully-converged result estimate in the minimum variance sense; this automated approach enables straightforward analysis of multiple quantities of interest and/or time and spatially-dependent response data. The overall numerical error analysis method is useful for verification and validation problems for stochastic simulation methods and forms a key component in the overall uncertainty quantification process. The method was demonstrated for steady and unsteady electron diode problems simulated using a particle-in-cell kinetic plasma code, demonstrating excellent results.
An approach, is proposed for the design of approximate, fixed order, discrete time realizations of stochastic processes from the output covariance over a finite time interval, was proposed. No restrictive assumptions are imposed on the process; it can be nonstationary and lead to a high dimension realization. Classes of fixed order models are defined, having the joint covariance matrix of the combined vector of the outputs in the interval of definition greater or equal than the process covariance; (the difference matrix is nonnegative definite). The design is achieved by minimizing, in one of those classes, a measure of the approximation between the model and the process evaluated by the trace of the difference of the respective covariance matrices. Models belonging to these classes have the notable property that, under the same measurement system and estimator structure, the output estimation error covariance matrix computed on the model is an upper bound of the corresponding covariance on the real process. An application of the approach is illustrated by the modeling of random meteorological wind profiles from the statistical analysis of historical data.
We address the problem of estimating steady-state quantities associated to systems of stochastic chemical kinetics. In most cases of interest, these systems are analytically intractable, and one has to resort to computational methods to estimate stationary values of cost functions. In this work, we introduce a novel variance reduction algorithm for stochastic chemical kinetics, inspired by related methods in queueing theory, in particular the use of shadow functions. Using two numerical examples, we demonstrate the efficiency of the method for the calculation of steady-state parametric sensitivities and evaluate its performance in comparison to other estimation methods.
In a parameter study of satellite orbits, sampling errors of area-time averaged rain rate due to temporal sampling by satellites were estimated. The sampling characteristics were studied by accounting for the varying visiting intervals and varying fractions of averaging area on each visit as a function of the latitude of the grid box for a range of satellite orbital parameters. The sampling errors were estimated by a simple model based on the first-order Markov process of the time series of area averaged rain rates. For a satellite of nominal Tropical Rainfall Measuring Mission (Thiele, 1987) carrying an ideal scanning microwave radiometer for precipitation measurements, it is found that sampling error would be about 8 to 12 pct of estimated monthly mean rates over a grid box of 5 X 5 degrees. It is suggested that an observation system based on a low inclination satellite combined with a sunsynchronous satellite simultaneously might be the best candidate for making precipitation measurements from space.
We develop a formalism for calculating forces on the nuclei within the linear-scaling stochastic density functional theory (sDFT) in a nonorthogonal atom-centered basis set representation (Fabian et al. Wiley Interdiscip. Rev.: Comput. Mol. Sci. 2019, 9, e1412, 10.1002/wcms.1412) and apply it to the Tryptophan Zipper 2 (Trp-zip2) peptide solvated in water. We use an embedded-fragment approach to reduce the statistical errors (fluctuation and systematic bias), where the entire peptide is the main fragment and the remaining 425 water molecules are grouped into small fragments. We analyze the magnitude of the statistical errors in the forces and find that the systematic bias is of the order of 0.065 eV/Å (~1.2 × 10 -3 E h / a 0 ) when 120 stochastic orbitals are used, independently of system size. This magnitude of bias is sufficiently small to ensure that the bond lengths estimated by stochastic DFT (within a Langevin molecular dynamics simulation) will deviate by less than 1% from those predicted by a deterministic calculation.