Search NASA⌕ Search

SEARCH · Search NASA

Results for “system performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Utilization of Existing Pipelines in Hydrogen Transport: Literature Review Report

This report critically reviews the flow behavior of hydrogen-natural gas (H 2 -NG) mixtures in pipelines and examines the critical factors of hydrogen integration into existing natural gas infrastructure. It addresses the choking behavior characterized by velocity increase and pressure drop, as well as the effects of flow restrictions and pressure losses during hydrogen transport. Computational and analytical models are used to investigate these effects, and their effects on thermodynamic properties and system performance are evaluated. The study also reviews the energy efficiency and flow dynamics of hydrogen and methane-hydrogen mixtures and optimizes the hydrogen flow rate. In addition, the effects of these mixtures on the flow characteristics are discussed in detail, with special emphasis on the compressibility factor (z factor) and fluid properties based on equations of state for hydrogen-natural gas mixtures. The study also analyzes the mixture ratios and highlights the thermophysical properties, flow dynamics, and hydrogen-blended natural gas application potential. These investigations assess flow stability, material interactions, and operational feasibility of transporting hydrogen mixtures through natural gas pipelines, which contribute to developing sustainable and efficient energy systems.

08 HYDROGEN↗

Interparticle Characterization of Mechanical Biomass Particle-Particle and Particle-Wall Interactions

The biomass materials industry faces significant challenges in managing material variability and its impact on storage and handling systems. Physical properties such as moisture content, particle size, and density fluctuate considerably, leading to operational issues like bridging and ratholing that disrupt material flow. These variations create a complex cascade effect throughout the process chain, affecting transportation, storage, and conversion processes. The economic consequences of this variability manifest in increased operational costs, maintenance requirements, and system downtime. Environmental factors further complicate the situation, as weather conditions and seasonal availability influence material properties and system performance. Engineers employ specialized equipment design, material characterization protocols, and pre-processing steps like size reduction and homogenization to address these challenges. A critical knowledge gap exists between continuous-level constitutive models and particle-scale behavior. This project developed a novel device to quantify interparticle mechanics between biomass particles, measuring friction and adhesion forces between particles and wall materials. The research focused on corn stover and southern pine forest residue, creating a comprehensive database of particle interactions. This breakthrough enables direct application in particle-based computational modeling, advancing the field's understanding of biomass handling characteristics and supporting the development of more reliable and efficient storage and handling systems. The project's outcomes contribute significantly to understanding biomass's mechanical and flow characteristics, particularly how variability at the particle level affects larger-scale handling operations. This knowledge is crucial for engineering feedstock supply systems that consistently meet quality and cost specifications for various conversion processes. The innovative experimental setup developed through this research represents a significant advancement in biomass characterization methodology. Providing precise measurements of particle-level interactions establishes a foundation for more accurate predictive modeling of bulk material behavior. This enhanced understanding of fundamental particle mechanics enables engineers to anticipate better and address handling challenges before they manifest in full-scale operations. This research opens new avenues for optimizing biomass handling systems through data-driven design approaches. The comprehensive database of particle interactions serves as a valuable resource for future research and development efforts, potentially leading to more efficient and cost-effective biomass processing solutions. This advancement in particle-level mechanics could revolutionize how biomass handling systems are designed and operated, contributing to more sustainable and reliable renewable energy production.

09 BIOMASS FUELS↗

Pacific Northwest National Laboratory Facility Radionuclide Emission Points and Sampling Systems

Battelle–Pacific Northwest Division operates numerous research and development laboratories in Washington State. The U.S. Department of Energy (DOE) contracts to Battelle at Richland facilities on both the DOE Hanford Site and the Pacific Northwest National Laboratory (PNNL) Richland campus. These facilities have the potential for radionuclide air emissions. The PNNL contract with DOE also includes operations at the PNNL-Sequim campus in Sequim, where there is also the potential for radionuclide air emissions. This document is a periodic update that describes current PNNL facility emission units and sampling systems. The National Emission Standard for Hazardous Air Pollutants (NESHAP [40 Code of Federal Regulations 61, Subpart H]) requires an assessment of all emission units that have the potential for radionuclide air emissions. Emission units are registered with the State of Washington. Potential emissions from emission units are assessed annually by PNNL staff. Sampling, monitoring, and other regulatory compliance requirements are designated based on the potential to-emit dose criteria, a graded approach to facility-identified potential impact categories, and regulatory requirements. The purpose of this document is to describe the facility radionuclide air emission sampling program and provide current and historical facility emission unit system performance, operation, and design information. For sampled emission units, the building, exhaust unit, control technologies, and sample extraction details are provided. Additionally, applicable configuration drawings, figures, and photographs are included. For non-sampled emission units, emission estimation and radionuclide source details are provided. Site-wide permits for the lowest potential impact category are described. Deregistered/transitioned emission unit details are also provided as necessary for at least 5 years post-closure/transition. Currently, five emission units are sampled continuously for particulate radionuclides at PNNL managed facilities on the PNNL-Richland campus (3 of the 5) and on the Hanford Site (2 of the 5). Four of these units have sampling systems that comply with the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1–2011 standard for sampling from stacks and ducts of nuclear facilities, and the fifth is grandfathered and compliant with the older ANSI N13.1–1969 standard. In addition, the PNNL-managed Hanford Site 325 Building EP 325-01-S stack is sampled continuously for emissions of tritium. No emissions sampling is required for the single licensed emission unit on the PNNL-Sequim campus.

54 ENVIRONMENTAL SCIENCES↗

Impact of refrigerant undercharge faults on building indoor conditions and HVAC system operation in residential Buildings: A simulation study

This study investigates the impact of refrigerant undercharge on indoor temperature and HVAC system performance in residential buildings. Simulation models for typical residential buildings in Orlando, FL and Indianapolis, IN were developed using the ResStock database. A refrigerant undercharge fault model was then applied to the simulations with varying levels of fault intensity. The paper offers an extensive analysis, revealing that variations in supply air temperature, equipment runtime, and cooling energy consumption due to the level of refrigerant undercharge faults are notably significant on a summer representative day. Similarly, on a winter representative day, changes in supply air temperature and runtime are significant as well as changes in supplemental heat energy consumption. We find that occupants may remain oblivious to these faults during the cooling season, particularly when the HVAC system is oversized; in that case, supply air temperature data could help detect a fault. Another challenge is that during the heating season, when the supplemental heater operates, it is difficult to identify a refrigerant undercharge fault using only indoor and supply air temperature data. Finally, this study finds that supply air temperature, equipment runtime, and supplemental heater energy consumption data can help in detecting refrigerant undercharge faults.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A practical control strategy for demand flexibility with ensured occupant comfort in grid-interactive efficient buildings

This study proposes a practical and simplified demand response (DR) control strategy from the perspective of grid-interactive efficient buildings (GEBs), aiming to secure demand flexibility while ensuring occupant thermal comfort. Focusing on summer on-peak periods, a linear demand response (LDR) strategy that integrates cooling setpoint adjustment and lighting dimming was designed, and its performance was quantitatively evaluated. A case study was conducted using EnergyPlus-based simulations for a U.S. DOE small office prototype building under summer on-peak weather conditions. Compared with a conventional rapid demand response (RDR) strategy, the proposed LDR approach gradually reduced electrical loads while maintaining occupant thermal comfort indices, including predicted mean vote (PMV) and predicted percentage of dissatisfied (PPD), within acceptable comfort ranges. Quantitative analysis of demand flexibility using the grid-interactive impact index (GII) and the flexibility strength index (FSI) showed that the LDR strategy provided approximately 12.5% demand flexibility during DR periods and achieved an electricity cost reduction of about 8.8%. In addition, the results of the part-load ratio (PLR)-based cooling system performance analysis showed that, in the on-peak period, the LDR strategy exhibited improved cooling performance compared with the baseline. Overall, this study shows the potential of a practical DR control strategy that can simultaneously achieve occupant comfort and demand flexibility without relying on complex advanced control technologies.

Jung, Dong Eun↗

Supervisory Control and Data Acquisition for Electrochemical Separation Experimentation

The Python-based program is a laboratory automation tool designed to control and monitor electrochemical systems. The tool was developed for capacitive deionization (CDI) experiments, but it can be used for any system that requires controlled voltage or current segments and multi-parameter monitoring. The program integrates hardware components to run user-defined experimental parameters, providing operational control of a programmable power supply, peristaltic pump, and data acquisition devices. Currently, the program is structured with a workflow that includes an initialization (or pre-run) phase, a main loop, and a post-experiment stabilization (or post-run) phase. The initialization phase prepares and stabilizes the cell, ensuring that the electrodes and solution reach a baseline state before the experiment begins. The main loop consists of multiple voltage segments that repeat, controlling the experiment while recording key parameters such as time, voltage, current, pH, and conductivity. Finally, the post-experiment stabilization phase allows the system to stabilize after the experiment, returning the cell and solution to equilibrium conditions before ending the sequence. The program is designed with four variations, each tailored to different experimental needs. All variations include both the initialization and post-experiment stabilization stages, which run for a set amount of time, voltage, current, and flow rate before and after the main experiment block. The main loop runs for a set number of cycles, as defined by the user input, and each cycle is composed of 2 or 4 segments. The 4 program variations are described as follows: Program 1: The main program includes 2 segments. Each segment is defined to have a set duration, flow rate, voltage, and current. This program measures conductivity, flow rate, voltage, and current. Program 2: The main program expands Program 1 to include 4 segments. Each segment has a specified duration, flow rate, voltage, and current. Like Program 1, it measures conductivity, flow rate, voltage, and current. Program 3: The main program consists of 2 segments, each defined by time, flow rate, voltage, and current. In addition to conductivity, flow rate, voltage, and current, Program 3 collects pH and temperature data through a 4-channel data acquisition device. Program 4: This program independently controls two channels of a multi-channel power supply simultaneously. While conductivity can only be measured for one cell at a time, the dual-channel control makes it possible to operate two cells simultaneously under different voltage/current conditions. The main program includes 2 segments.For each program, all measurements are automatically logged and integrated into a single Excel output file. Data are displayed in numerical format and plotted, both in real time, to track system performance. A key feature of the program is its ability to synchronize all outputs so that every measurement shares a single timestamp, ensuring accurate alignment of voltage, current, pH, conductivity, and pH data.By combining hardware control, real-time monitoring, and unified data collection, this program significantly reduces manual workload and minimizes errors, making it a reliable platform for researchers, engineers, and laboratory technicians conducting CDI experiments, among other electrochemical tests.

Valentino, Lauren [Argonne National Laboratory (AN↗

Microscopic Imprints of Learned Solutions in Tunable Networks

In physical networks trained using supervised learning, physical parameters are adjusted to produce desired responses to inputs. An example is an electrical contrastive local learning network of nodes connected by edges that adjust their conductances during training. When an edge conductance changes, it upsets the current balance of every node. In response, physics adjusts the node voltages to minimize the dissipated power. Learning in these systems is therefore a coupled double-optimization process, in which the network descends both a cost landscape in the high-dimensional space of edge conductances and a physical landscape—the power dissipation—in the high-dimensional space of node voltages. Because of this coupling, the physical landscape of a trained network contains information about the learned task. Here, we derive a structure-function relation for trained tunable networks and demonstrate that all the physical information relevant to the trained input-output relation can be captured by a tuning susceptibility, an experimentally measurable quantity. We supplement our theoretical results with simulations to show that the tuning susceptibility is correlated with functional importance and that we can extract physical insight into how the system performs the task from the conductances of highly susceptible edges. Our analysis is general and can be applied directly to mechanical networks, such as networks trained for protein-inspired function such as allostery.

36 MATERIALS SCIENCE↗

An On-Demand Electric Transit Case Study of New Rochelle, New York

Here, this article characterizes the performance and ridership patterns of an on-demand transit (ODT) service utilizing lightweight electric vehicles (EVs) in New Rochelle, New York. Ridership sociodemographics, travel patterns (both temporal and spatiotemporal), and energy use from the service were explored using travel and survey data from September 2019 through December 2023. The ODT service was found to be used more by women (nearly 60%) and younger demographics (>65% under the age of 42), with peak use in the middle of the day and a grocery store as a top origin and destination. The service was utilized primarily for short trips (86% under 2 mi), with approximately one-third of riders using the ODT service to connect to a train or bus. The costs associated with fueling/charging were compared for different types of fleet vehicles, and the small, right-sized EVs were found to have annual charging costs that were roughly half of the refueling costs for conventional hybrid vans, and 24 times lower than a fleet of diesel buses. Evaluating the vehicle fleet and mapping current socio-spatial travel demand can inform system performance, guide service area development, and support future planning such as expansion to nearby communities and transit hubs. The findings in this case study suggest that on-demand electric transit may be a significant and growing space for advancing highly valued public mobility services. Public transport interventions that consider right-sized, electric, on-demand vehicles can help improve mobility access and reduce energy use and refueling costs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

An update to the Sandia method for creating Typical Meteorological Years from a limited pool of calendar years

Typical Meteorological Years (TMYs) are essential for the efficient evaluation of energy system performance. Ideally, 30 years of weather data are required to generate TMYs, but significantly fewer years are typically available due to practical limitations. To address this issue, an update to the Sandia method was developed, referred to as the Argonne method, to create TMYs from a limited number of years. Furthermore, this method enhances candidate diversity by systematically shifting original candidate months forward or backward by specific days, creating an expanded pool of candidates. The effectiveness of the Argonne method was validated through statistical testing, comparison of monthly average weather parameters, and numerical simulations. The results demonstrate a high probability of identifying at least one shifted month whose cumulative distribution functions of weather parameters closely align with long-term distributions. In 67 % of all comparisons, the monthly average weather parameters in TMYs generated using the Argonne method exhibit better agreement with long-term averages than TMY3. Moreover, in 74 % of the 318 building simulation cases, the Argonne method outperforms TMY3 in estimating long-term average building heating and cooling demands. Therefore, the Argonne method effectively diversifies the candidate pool and produces typical years that provide more accurate estimations of long-term averages compared to TMY3 when only a limited pool of calendar years (10 years or fewer) is available.

Building energy modeling↗

Flame Chemistry Workshop: a perspective on challenges and strategic actions in combustion experiments and chemical kinetics modeling

Continued progress in the development of predictive models for combustion chemistry—including ignition and flame behavior, species evolution, and combustion system performance—relies on overcoming enduring and emerging challenges in experimental measurements, theoretical formulations, and chemical kinetics mechanism construction. As combustion science continues to coincide with advances in sustainable fuels development, plasma technologies, and automated modeling capabilities, the need for coordinated, community-driven strategies is essential. The Flame Chemistry Workshop (FCWS), held biennially before the International Symposium on Combustion, serves as a dedicated platform to identify, consolidate, and address these challenges in a structured and collaborative manner. This perspective arises from discussions at the 7th FCWS in Milan, Italy (2024), and presents a collective view of the critical barriers currently limiting progress. Across the five technical domains discussed during the 7th FCWS – sustainable fuels combustion, advanced diagnostics for combustion measurements, experiments and modeling in plasma combustion, artificial intelligence and automated methods for theory and mechanisms generation, and chemical kinetic models—a series of persistent and emerging scientific challenges were identified, highlighting the need for deeper integration between three areas: theory, experiments, and modeling. In conclusion, the present article concisely describes present challenges that were identified in each of the technical domains in an effort to streamline and coordinate solutions to accelerate progress in combustion science.

Chemical kinetics↗

The spherical tokamak advanced reactor (STAR) fusion power plant design

Scientific and technical advancements have been made that improve fusion’s prospects to provide a new energy source, showing enhanced plasma confinement conditions with plasma temperatures reaching or exceeding 100 million degrees. Overshadowing this progress is the challenge involved in developing an economically viable fusion power plant design. Many proposed next-step DEMO and pilot plant designs are extensions of existing physics-focused experimental devices defined to understand and control plasma operations to achieve and sustain a fusion reaction. Transitioning scientific and technical advancements into a functional power plant requires a dedicated focus on architectural designs that integrate diverse technologies, while optimizing physics conditions, with a focus on economic viability. This holistic approach is essential in turning the promise of fusion energy into a reality. The Spherical Tokamak Advanced Reactor (STAR) is a fusion power plant conceptual design with the architectural focus that strives to balance physics, engineering, and cost considerations. In conclusion, it has been set up to introduce relevant physics, engineering and concept features that an intermediate pilot plant might follow, with the goal of meeting system performances and economic requirements that lead to a commercially competitive fusion power plant.

Blanket segmentation↗

Capillary-Enhanced Two-Phase Micro-Cooler Using Copper-Inverse-Opal Wick with Silicon Microchannel Manifold for High-Heat-Flux Cooling Application

In this work, we demonstrate a two-phase capillary-fed boiling micro-cooler that consists of a ~ 25-..mu..m-thick copper inverse opal (CIO) porous wicking structure for high-heat-flux boiling and a silicon 3D-manifold for distributed liquid delivery and vapor extraction across a 0.5 cm x 0.5 cm heated area. At low inlet water mass flow rates of 1.5 to 1.9 g(min)-1, the micro-cooler displays nearly two-phase boiling with exit vapor quality ~ 1 and a high critical heat flux (CHF) of 253 to 320 W cm-2 with low superheat of ~ 10 degrees C resulting in a thermal resistance of boiling ~ 0.025 cm2 degrees C W-1 or heat transfer coefficient of 0.4 MW m-2 degrees C-1. For higher flow rates of 5, 10, and 15 g(min)-1, the micro-cooler exhibits a hybrid single-phase and two-phase cooling regime where the contribution of the sensible heat (single-phase) cooling is linearly added to that of the two-phase cooling. For the highest flow rate of 15 g(min)-1, the CHF is increased to ~ 500 W cm-2 resulting in an overall thermal resistance of ~ 0.18 cm2 degrees C W-1. However, the two-phase heat transfer effectiveness, which estimates the utilization level of the inlet mass flow rate for two-phase boiling, is reduced to ~ 0.11. To achieve the best cooling system performances, the micro-cooler must operate entirely within the two-phase boiling regime (exit vapor quality or two-phase heat transfer effectiveness ~ 1). Ideally, the "coolant" should be delivered near its saturation temperature (~ 100 degrees C for water), which provides significant advantages for the energy-efficient operation of data centers and power electronics. We present detailed analysis with Infrared and high speed camera images at various inlet flow rates and heat fluxes to understand complex heat transfer in the micro-cooler. Furthermore, a conjugate thermofluidic simulation model, which incorporates the physics of capillary-fed boiling in a porous copper layer, agrees well with the experimental data.

capillary-enhanced boiling↗

In-situ strain behavior and BISON simulations of Zircaloy cladding subjected to temperature cycling separate-effects tests in a steam environment

Understanding fuel system performance during anticipated transients without scram (ATWSs) in boiling water reactors (BWRs) is necessary for refining current and future safety limits. High-fidelity material models and simulations are fundamental to rigorous assessment of zirconium-based cladding performance. However, experimental thermomechanical data during simulated ATWSs to validate these modes are limited. To provide relevant in-situ data, Zircaloy-4 cladding was subjected to cyclic heating in a steam environment to simulate an out-of-pile BWR ATWS. Digital image correlation was used to capture the cladding strain behavior in-situ for comparison against simulations using the BISON finite element code. Conventional high-temperature models were compared using multiple schemes to gain a better understanding of the applicability of three BISON models to BWR ATWS: (1) the default combination of creep models in BISON, (2) the high-temperature Erbacher model alone, and (3) the low-temperature Limback-Andersson model alone. The cases run with the Limback-Andersson model alone produced the lowest root mean square error (RMSE). The lowest RMSE for the Limback-Andersson model alone was 0.659%, and the highest RMSE reported was 4.22%. A data gap within the model in the temperature regime of interest was also identified, and to account for this gap, the current model in BISON is linearly interpolated between two separate datasets. In conclusion, this evaluation highlights the need to either develop a new model or to improve the existing model to capture transient creep effects resulting from a cyclic temperature transient.

Anticipated transient without SCRAM↗

High-emissivity, thermally robust emitters for high power density thermophotovoltaics

Thermal radiative energy transport is essential for high-temperature energy harvesting technologies, including thermophotovoltaics (TPVs) and grid-scale thermal energy storage. However, the inherently low emissivity of conventional high-temperature materials constrains radiative energy transfer, thereby limiting system performance and technoeconomic viability. Here, in this study, we demonstrate ultrafast femtosecond laser-material interactions to transform diverse materials into near-blackbody surfaces with broadband spectral emissivity above 0.96. This enhancement arises from hierarchically engineered light-trapping microstructures enriched with nanoscale features, effectively decoupling surface optical properties from bulk thermomechanical properties. These laser-blackened surfaces (LaBS) exhibit exceptional thermal stability, retaining high emissivity for over 100 h at temperatures exceeding 1,000°C, even in oxidizing environments. When applied as TPV thermal emitters, Ta LaBS double electrical power output from 2.19 to 4.10 W cm −2 at 2,200°C while sustaining TPV conversion efficiencies above 30%. This versatile, largely material-independent technique offers a scalable and economically viable pathway to enhance emissivity for advanced thermal energy applications.

laser-blackened surfaces↗

Radiation portal monitor data file format for comprehensive background radiation monitoring

Radiation portal monitors (RPMs) are widely used at border security checkpoints to detect the presence of radioactive materials in people, vehicles, and cargo. Typically, RPM detection systems consist of two pillars equipped with gamma and neutron detectors. To improve detection efficiency, RPMs employ techniques such as a limited energy window, dynamic alarm thresholds, and lead shielding. However, without continuous monitoring of background radiation, signal interpretation can be compromised, because environmental factors and mechanical failures can cause fluctuations. Here, we introduce a daily file format that logs gamma background and neutron background radiation levels continuously over a 24 h period; this format is different from traditional formats that record data only when the RPM is active or occupied. The approach enables RPM operators and analysts to (1) identify and diagnose malfunctioning components, (2) adjust system settings to account for dynamic environmental factors, and (3) use the recorded data to characterize outer space phenomena. Continuous background reporting is essential for identifying issues such as faulty connections, voltage divider failures, and errors in background updates. Continuous background reporting also enables the detection of external influences, including nearby X-ray scanners, temperature fluctuations, rainfall, cosmic radiation, and lunar phase changes. These data files are designed to be easily evaluated and parsed using common tools, and a quick review by an expert is often sufficient for problem diagnosis. We anticipate that continuous background radiation monitoring and these new strategies will significantly improve the accuracy and reliability of RPM systems, reducing the rate of false alarms and enhancing overall system performance.

Background radiation monitoring↗

Model-driven prediction for accelerator magnet diagnostics to improve operation reliability

Reliability is one of the most critical metrics for accelerator operation, especially in user facilities. To reduce costly facility downtime and provide an operational environment where system performance can be reliably predicted in support of scientific studies, we are developing a model-driven approach for prediction and anomaly detection. Here, in this study, we present the application of a model-driven method that employs a linear regression model to predict the future temperature, in real time, of accelerator magnets at the NSLS-II light source. This approach enables proactive identification of magnet-heating issues, facilitating magnet flushing prior to the occurrence of permanent damage without interrupting machine operation. The implementation of this method in the NSLS-II control room is described and the analysis of the online results is presented. The results demonstrate the model’s effectiveness in providing early alerts to engineers and improving the reliability of accelerator operations.

36 MATERIALS SCIENCE↗

Influence of Surfactants on Noble Metal Liquid-Gas Interface Mass Transfer in Molten Salt Reactors

Noble metals, a group of insoluble fission products (FPs), can accumulate in molten salt reactors (MSRs) and influence system performance and safety through deposition. Upon generation in fission, noble metals are transported by circulating salt and may either deposit on structural surfaces or enter the circulating gas bubble interfaces. While sparging was primarily designed for xenon and krypton removal, the mass transfer of noble metals into bubble interfaces highlights a potential pathway for their transport and partial extraction. The properties of the liquid-gas interface therefore play an important role in noble metal deposition and removal behaviors. Observations from earlier studies suggest that noble metals accumulated at the bubble interface can act as surfactants, making the bubble interface partially immobile. This behavior reduces the mass transfer capacity of circulating bubbles and affects both the overall distribution of noble metals in the loop and their removal efficiency. To investigate the influence of surfactants on noble metal transport, deposition, and extraction behaviors in MSRs, a previously developed and validated species transport model incorporating noble metal interphase mass transfer was used to simulate these behaviors. Two designed cases were studied to predict the distribution of 132Te along the Molten Salt Reactor Experiment (MSRE) loop under different bubble interface conditions. The results show that the mass transfer coefficients at the liquid-gas interface, determined by bubble interface characteristics, significantly influence noble metal distribution within the reactor loop. These findings emphasize the importance of continuously introducing fresh circulating bubbles into the molten salt to improve the removal efficiency of insoluble FPs from the MSR primary loop.

MSR↗

Primary Heat Transport System Design Considerations for Xcimer Energy’s Athena Fusion Pilot Plant

Fusion energy promises a reliable, carbon-free source of power; however, significant challenges remain before it can be deployed as an economical energy source. In addition to achieving fusion conditions, power plants must operate under extreme temperatures, radiation, and mechanical loads while maintaining high efficiency and availability. These requirements place strong demands on engineering design and plant operation. This work focuses on the engineering challenges associated with balance of plant analysis for inertial fusion energy systems. In particular, this paper examines the design considerations for primary heat transfer systems in fusion pilot plants employing molten fluoride salt coolants, with particular emphasis on system layout optimization and the balance between competing design objectives using the Xcimer Energy Athena inertial pilot plant design as a case study. Through systematic analysis of candidate system configurations and parametric sensitivity studies, we identify key engineering trade-offs governing salt inventory, pumping power requirements, and operational flexibility. The analysis employs system-level modeling tools to explore the design space and establish relationships between geometric parameters and system performance metrics.

Greenwood, Scott [ORNL] (ORCID:0000000333480736)↗