Search NASA⌕ Search

SEARCH · Search NASA

Results for “system-level performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Solar PV, Wind Generation, and Load Forecasting Dataset for ERCOT 2018: Performance-Based Energy Resource Feedback, Optimization, and Risk Management (P.E.R.F.O.R.M.)

This report describes the Advanced Research Projects Agency-Energy Performance-Based Energy Resource Feedback, Optimization, and Risk Management (PERFORM) Electric Reliability Council of Texas (ERCOT) dataset consisting of load, solar, and wind deterministic and probabilistic forecasts at three timescales. This dataset consists of 1 year of time-coincident load, wind, and solar actuals and probabilistic forecasts for a region similar to ERCOT. All the data are stored in Hierarchical Data Format 5 (HDF5) files and have been uploaded to an Amazon Web Services repository. The ERCOT data set has 2 years (2017, 2018) of actuals and 1 year (2018) of probabilistic forecasts. These data are provided at various spatial (i.e., site-level, zone-level, and system-level) and temporal scales (i.e., day-ahead, intraday, and intra-hour). Specifically, data are provided for 125 existing wind sites, 22 existing solar sites, 139 proposed wind sites, and 204 proposed solar sites.

14 SOLAR ENERGY↗

Energy Savings With Acceptable Indoor Air Quality Through Improved Airflow Control in Residential Retrofits

The Partnership for Advanced Residential Retrofit (PARR) has been a U.S. Department of Energy (DOE) Building America team since 2009, with a primary focus on upgrading the performance of existing buildings to reduce energy loads. In this project, PARR’s work explored the integration of airflow-focused measures in residential retrofit homes with the goal to maximize energy savings while ensuring acceptable indoor air quality (IAQ) using a systems approach to controlling four contributing air streams: • Building air leakage (natural, uncontrolled infiltration), • Forced-air distribution system static pressure and airflow rate, • Distribution system duct leakage, and • Mechanical ventilation. This project addressed airflows in houses, their combined impact on energy use and IAQ, and the comparative effects of typical insulation and air sealing practices versus integrated system-level retrofits. Additionally, practical considerations for contractors taking either approach were addressed. Finally, the effects of supply ventilation and exhaust ventilation on IAQ were compared in occupied homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multi-Physics System-level Simulations of a Generic Pebble Bed High-Temperature Gas Cooled Reactor with Coupled SAM/Griffin Model

A SAM model for a 200 MWth generic pebble bed high-temperature gas-cooled reactor (PBHTGR) is presented in this work. As an extension to the modeling effort from FY-22 (Ooi et al. (2022)), an improved core channel approach is used to model the pebble bed of the reactor. The improvement greatly simplifies the model and reduces the run time of the model. Furthermore, the SAM model is coupled to the Griffin reactor physics model from Stewart et al. (2021) using the MOOSE MultiApp system where neutronics calculations are performed by the Griffin model and thermal hydraulics calculations by the SAM model. Favorable predictions are produced by the SAM/Griffin coupled model for steady-state normal operating condition. A load-following transient is also simulated with the coupled model where the neutronics and thermal hydraulics responses of the core are predicted correctly by the model. A protected Pressurized Loss of Forced Cooling (PLOFC) accident is simulated with the SAM model, in which the reactor power is determined using the decay heat curve, and therefore the Griffin model is not needed and thus decoupled. A simplified RCCS (Reactor Cavity Cooling System) loop is added to the model to remove decay heat from the core during the transient. Qualitatively, the prediction by the SAM model matches the expected behavior of a PB-HTGR during a PLOFC accident.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Comparison Between Pin-by-Pin Subchannel and System Level Thermal Hydraulic Results for High Burnup Loss-of-Coolant Applications

This milestone report summarizes recent work to investigate higher fidelity modeling and simulation practices for large-break loss-of-coolant accident (LBLOCA) analysis in high-burnup pressurized water reactor (PWR) cores. Because of current industry interest in extending fuel cycle lengths ranging from 18 to 24-months, the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program has been investigating the susceptibility of high-burnup core designs to fuel fragmentation, release, and dispersal (FFRD) during accident conditions such as LBLOCA. This work has prioritized developing and demonstrating a methodology for calculating core-wide susceptibility to FFRD and addressing uncertainties identified in the analysis and the US Nuclear Regulatory Commission (NRC) Research Information Letter on FFRD. Part of this investigation seeks to quantify differences between system-level thermal hydraulic behavior and higher fidelity subchannel modeling methods to identify potential safety concerns or opportunities to minimize FFRD susceptibility. To this end, the NEAMS subchannel code, CTF, is being used, along with the NRC system analysis code TRACE, for analysis of LBLOCA in a core containing high-burnup fuel. This project includes two thrusts: (1) improving on the existing TRACE model for a 4-loop PWR for LBLOCA so that the model is higher fidelity and consistent with current USNRC best practices, and (2) using CTF to perform pin-resolved modeling of the core region of the reflood phase of a LBLOCA in a high-burnup PWR.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Digital Engineering and Cybersecurity Decision Analysis in Early Phases of SMR-Driven IES Projects

Considerable efforts are underway to ensure cybersecurity is integrated into the systems engineering lifecycle. Cyber-informed engineering and security-by-design frameworks are intended to identify and engineer out cybersecurity risks throughout the lifecycle. While these approaches are valuable for promoting the need to include cybersecurity considerations in early design phases to create more secure systems, they may not consider the entirety of digital risks. Digital risks in a digital instrumentation and control system include adversarial and unintentional risks from internal and external factors, such as human performance errors, design flaws, environmental conditions, and equipment degradation or failure. This report provides a detailed discussion on digital risk prior to describing the background and concept of operations for a small modular reactor-driven integrated energy system connected to industrial applications. The challenges of competing objectives and competing stakeholder requirements are discussed and the impacts on digital engineering, security considerations, and interdependencies are evaluated for mission-level, facility-level, and system-level decisions.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Optimizing Information Automation Using a New Method Based on System-Theoretic Process Analysis: Tool Development and Method Evaluation

This report is an update to a prior report that describes progress and findings for a program of research supporting the design and optimization of information automation systems for nuclear power plants. Much of the domestic nuclear fleet is currently focused on modernizing technologies and processes, including transitioning toward digitalization in the control room and throughout the plant, along with a greater interest in the use of automation, artificial intelligence, robotics, and other emerging technologies. While there are significant opportunities to apply these technologies toward greater plant safety, efficiency, and overall cost-effectiveness, optimizing their design and avoiding potential safety and performance risks depends on ensuring that human performance-related organizational and technical design issues are identified and addressed early in the design process. This report describes modeling tools and techniques, based on sociotechnical systems theory, to support these design goals and their application in the current research effort. The report is primarily intended for senior nuclear energy stakeholders, including regulators, corporate management, and senior plant management. We have developed and employed a method to design an optimized information automation ecosystem (IAE) based on the systems-theoretic constructs underlying sociotechnical systems theory in general and the Systems-Theoretic Accident Modeling and Processes (STAMP) approach in particular. We argue that an IAE can be modeled as an interactive information control system whose behavior can be understood in terms of dynamic control, feedback, and communication relationships amongst the system’s technical and organizational components. We have employed two STAMP-based tools in this effort. The first is Causal Analysis based on STAMP (CAST), an accident and incident analysis technique that was used to examine a performance- and safety-related incident at an industry partner’s plant involving the unintentional activation of an emergency diesel generator. This analysis provided insight into the behavior of the plant’s current information control structure within the context of a specific, significant event. The second tool is Systems Theoretic Process Analysis (STPA) which is a proactive risk analysis tool used to examine existing and potential, planned sociotechnical systems. STPA was used to identify risk factors in the current design of a generic nuclear power plant (NPP) preventive maintenance system. Our analyses focused on identifying near-term system improvements and longer-term design requirements for an optimized IAE system. CAST analysis findings indicate an important underlying contributor to the incident under investigation, and a significant risk to information automation system performance, was perceived time and schedule pressure, which exposed weaknesses in interdepartmental coordination between and within responsible plant organizations and challenged the resilience of established plant processes, until a human caused the eventual event. These findings are discussed in terms of their risk to overall system performance and their implications for information automation system resilience and brittleness. STPA findings exposed several areas of concern in the design of current preventive maintenance systems. We also present two preliminary information automation models. The proactive issue resolution (PIR) model is a test case of an information automation concept with significant near-term potential for application and subsequent reduction in significant plant events. The IAE model is a more general representation of a broader, plantwide information automation system and represents an end-state vision for our work. From our results, we have generated an initial set of preliminary system-level requirements and safety constraints for these models. We have also focused on early development of easy to learn, easy to use “transportable” tools for sociotechnical systems analysis. We intend these to be used by NPP personnel as a means of gaining reliable and relatively quick insight into (1) sociotechnical systems factors impacting incidents and accidents, (2) potential sociotechnical risk factors in existing or planned system designs, and (3) potential weaknesses in a system’s safety and/or information control structure. We conclude the report with a set of summary recommendations, a discussion of planned and potential follow-on research and development, and a draft list of system-level requirements and safety constraints for optimized information automation systems.

99 GENERAL AND MISCELLANEOUS↗

Freeform thermoelectrics in single-step manufacturing: additive manufacturing of bismuth-telluride thermoelectrics

The project succeeded in producing crack-free Bismuth Telluride thermoelectric parts with density exceeding 98% through laser powder bed fusion (LPBF) additive manufacturing (AM). This greatly exceeded the highest previously reported density of 88% and is the highest among all semiconducting materials processed by LPBF. The additively manufactured material shows comparable Seebeck coefficient as conventional form and can be made into complex geometries with reduced material loss. On the other hand, measured properties are dramatically sensitive to the AM process parameters used, such that with identical composition, the Seebeck coefficient can be controllably tuned from +120 µV/K to -207 µV/K, which means the material switches between an n-type to a p-type semiconductor depending on processing. These changes are accompanied by significant differences in the as-processed microstructure due to rapid solidification. A machine learning protocol was developed and greatly reduced the experimental burden of the project, reducing the typical process optimization period of 2 years to 6 months. The project was fully successful in the objective of producing defect-free, complex geometry of bismuth-telluride parts through LPBF, but only partially successful in achieving performance goals. First, cost reduction of manufacturing, as measured by material waste, was successfully reduced by up to 70% compared to conventional manufacturing methods. This exceeded the proposed 30% reduction in materials waste needed to reach the 20% cost reduction goal of the project. On the other hand, the device performance, as measured by Seebeck coefficient, failed to reach the 40% improvement in efficiency. Rather, we observe comparable Seebeck coefficient between AM samples and conventionally processed counterparts. The device-level efficiency improvement does exceed 40% for complex geometry samples due to shape-induced increase in temperature gradients, but this was not the originally proposed metric. The machine learning approach developed in this project greatly accelerated the process optimization and can be adopted for fast development of AM processing parameters for other brittle and otherwise difficult-to-print materials. For the public, we deliver an efficient and widely adoptable process for incorporating waste-heat harvesting thermoelectric devices in both industrial and commercial heat exchangers. The geometric flexibility allows the capturing device to conform to the shape of the heat source to improve the system-level conversion efficiency. The technique can be deployed on any commercial LBPF systems with zero modifications, thus poses minimal adoption barrier for any manufacturer that already employed AM technology. Beyond bismuth-telluride, the machine-learning guided optimization protocol can be used in the future to reduce both the time and cost of process development for AM of other energy conversion and harvesting materials.

36 MATERIALS SCIENCE↗

Design of Defensive Cybersecurity Architectures for High Temperature, Gas-Cooled Reactors

This report presents the design of defensive cybersecurity architectures (DCSAs) for High Temperature, Gas-Cooled Reactors (HTGRs). A DCSA is a cybersecurity design feature that places systems into security zones in a graded approach according to the importance of the functions performed by the systems. DCSA design efforts for advanced reactors may commence as early as the system-level design phase. This design approach is consistent with the draft regulatory guide for advanced reactor cybersecurity programs (DG-5075) and enables advanced reactor designers to consider the effects of security-by-design (SeBD) features on their DCSAs. Integration of DCSA design and other cybersecurity activities with the traditional design process as part of a SeBD framework may enable advanced reactor designers to improve the security posture of their plants while reducing implementation and operating costs. This report provides a DCSA template for an exemplar HTGR and describes a DCSA design process using event tree analysis so that the template may be optimized for a given HTGR design.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Autonomous Fueling System for Heavy-Duty Fuel Cell Electric Trucks

The motivation for this project stemmed from the challenges associated with rapidly refueling heavy-duty hydrogen fuel cell electric trucks (FCETs). Current manual refueling processes for fast refueling involve large, heavy equipment (e.g., hoses three times heavier than standard) and pose ergonomic risks and potential for equipment damage. The goal was to develop and test an autonomous fueling system to improve ergonomics, enhance safety, increase equipment durability through design improvements, and potentially speed up the fueling process. This project aimed to add to the understanding of autonomous systems in the context of heavy-duty hydrogen refueling, evaluating the technical effectiveness of potential concepts. A successfully developed system would benefit the public by facilitating the adoption of zero-emission heavy-duty transport, reducing reliance on manual labor for a physically demanding task, and potentially improving the safety and efficiency of hydrogen refueling infrastructure. The major accomplishment during the project's active period was the completion of the system-level architecture task. This involved establishing a detailed list of system requirements covering interfaces, environmental conditions, regulatory compliance, industry standards, safety, security, performance capabilities, and optional features. Five key use cases for the autonomous system were also identified. However, due to internal restructuring at Nikola, the necessary resources could not be allocated to continue the project. Consequently, Nikola opted to discontinue the project. The award was mutually terminated by Nikola and the DOE.

08 HYDROGEN↗

Assessing the Impact of Lubrication on Efficiency and Life Cycle Economics of the US Wind Turbine Fleet: Cooperative Research and Development (Final Report)

As with any mechanical system, lubrication plays a key role in the performance of wind turbines used to generate electricity. The lubricant design offers a way to optimize the competing requirements of efficiency, component reliability, and maintenance strategy. This project will estimate the impact of improved lubrication on the levelized cost of energy of the US wind turbine fleet as a means of identifying opportunities for disruptive innovation or system-level optimization. The models developed will provide a clear understanding of the benefits and potential for advanced lubrication of wind turbines. The project will enable identification of high value targets for wind turbine component suppliers and a roadmap that highlights where the greatest return on technology investment can be achieved. This will promote efficient resource allocation in areas of new technology development.

17 WIND ENERGY↗

Intelligently Partitioned Phasor-EMT Hybrid Simulations of Large-Scale, High-IBR Power Systems

As the penetration level of power electronics-interfaced renewables such as photovoltaics (PV) and wind has surged in modern electric grids, new operational risks caused by the dynamics of those inverter-based resources (IBRs) are emerging in parallel. Lessons learned from various grid events include that the impact of IBRs on system-level grid stability will become prominent along with the increase of renewables and that the short-timescale dynamic impacts of IBRs on grid stability are not fully captured by current commercial dynamic simulation tools [1] [2]. For example, IBRs can be controlled to mitigate those destabilizing interactions, but conventional phasor-domain tools (e.g. PSS/E, PSLF) often cannot capture that; likewise, the existing electromagnetic transient (EMT) simulation tools (e.g. PSCAD, EMTP) can simulate detailed IBR controls, but for large power systems with many IBRs, slow simulation speeds severely impede the ability to study dynamic events [3] [4]. Massively paralleling simulations using high-performance computing (HPC) can help address this, especially now that cloud-based HPC capability is widely available, but today s EMT tools are not HPC-compatible, and parallelization of dynamic simulation solvers is not trivial because each region can dynamically affect the others. Thus, dynamic simulation of grids with very large numbers of IBRs potentially poses a barrier to the ongoing energy transition.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Unified Universal Control and Coordination of Inverter-Based Resources, and Validation for a PV + Battery Hybrid Plant

As renewable energy deployment grows, hybrid power plants (HPPs) combining photovoltaic (PV) and battery systems must evolve to offer both energy and grid stability services. These systems typically include a mix of grid-following (GFL) and grid-forming (GFM) inverters, presenting unique coordination and control challenges. This Department of Energy–funded project developed and validated a Unified Universal Control and Coordination (UUCC) framework for such PV + battery hybrid plants, enabling seamless and stable operation, including ultrafast black start, autonomous synchronization, and robust frequency and voltage regulation, under different grid conditions. The project significantly advanced the understanding of inverter-based resource (IBR) control by developing and validating three complementary system-level approaches for hybrid GFL/GFM operation: 1. A combined Virtual Resistance (VR)-based GFL and Virtual Oscillator Control (VOC)-based GFM method, where each inverter type is governed by a specialized control strategy. Together, these achieve stable, fast-response coordination, eliminating inrush current and enabling smooth black start and grid synchronization across a wide range of grid strengths. 2. A Deadbeat-based UUCC strategy, which uses discrete-time, switching-cycle-level control for both GFL and GFM inverters. This approach replaces traditional PI/PLL control with a control parameter-free, high-bandwidth framework that supports stable LVRT and instantaneous synchronization under all conditions. 3. A benchmark comparison with Siemens’ commercial GFM microgrid controller, which provided a fast baseline platform. The commercial approach decoupled v & f control was implemented on a commercial microgrid controller.The baseline commercial benchmark helped highlight superior transient response and black start performance offered by the deadbeat and VOC approaches. These technical contributions offer substantial improvements over conventional inverter control schemes, which often rely on slow phase-locked loop (PLL)-based synchronization, require careful control parameters tuning, and prone to unstable in weak grids with GFL inverters and in stiff grid with GFM inverters therefore challenging for hybrid GFL+GFM under all grid conditions. The deadbeat-based UUCC framework enables simpler, faster, and more robust operation of hybrid IBR systems using wide-bandgap (WBG) devices such as SiC power semiconductors. The rapid expansion of hybrid distributed energy resources (DERs), including residential and commercial PV-BESS installations such as Tesla Powerwall, PV with vehicle-to-grid (V2G) capability, and other integrated configurations, presents complex operational challenges for medium-voltage radial distribution feeders. These networks are subject to frequent disturbances such as faults, switching operations, rapid reclosing sequences, and feeder reconfigurations, all of which introduce dynamic stress on IBRs. In addition, planned feeder segmentation and deliberate islanding for resilience will require DERs that can autonomously perform blackstart, establish voltage and frequency references, and resynchronize with the main grid. The advanced deadbeat-based UUCC control and blackstart functionalities developed in this project directly address these requirements, enabling decentralized and autonomous operation of inverter-dominated DERs in distribution systems under a wide range of fault and reconfiguration scenarios. From a public benefit perspective, these innovations enable more reliable and cost-effective integration of renewable energy into distribution networks. The ability to autonomously black start and stabilize grids under varying grid conditions support accelerates recovery from outages and support decentralized resilient energy systems. By reducing system complexity and improving performance, this project lays critical groundwork for future inverter-dominated power grids that are clean, reliable, and accessible to all.

14 SOLAR ENERGY↗

Conjugate Heat Transfer Modeling of Salt-Filled Fuel Pins for Stable Salt Reactor Safety Analysis

The Stable Salt Reactor (SSR) combines the proven structural design of light water reactor fuel assemblies with the inherent safety and fuel-cycle advantages of molten salt technology. In its fast reactor configuration, the SSR utilizes recycled nuclear waste as fuel, sealed within narrow salt-filled fuel pins and cooled by a surrounding liquid salt coolant. Reliable transfer of heat from the molten fuel salt through the cladding to the external coolant is essential for both reactor safety and performance. This work investigates conjugate heat transfer (CHT) in the SSR’s salt-filled fuel pins using NekRS, a high-fidelity spectral element computational fluid dynamics (CFD) solver. The analyses capture internal natural convection within the molten fuel salt and external forced convection in the coolant, under steady-state and transient operating conditions. Parametric studies evaluate how variations in reactor power and coolant flow rate influence heat transfer distributions and system response. The high-fidelity CFD results are time-averaged and post-processed for direct comparison with moderate-fidelity Reynolds-averaged Navier–Stokes (RANS) models, and for the development of reduced-order models within the SAM system code. These validated models support fast-running safety analyses of normal and off-normal transients, improving predictive capability for key safety margins. By integrating advanced CFD with system-level safety tools, this study strengthens the modeling framework for SSR design, reduces uncertainty in molten salt CHT simulations, and accelerates the engineering and licensing of next-generation nuclear reactors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Organic Rankine Cycle Integration and Optimization for High Efficiency CHP Genset Systems (Final Technical Report)

This project successfully advanced the integration of Organic Rankine Cycle (ORC) technology with reciprocating engine–based combined heat and power (CHP) systems to improve electrical efficiency, total CHP efficiency, and grid-responsive operation. Over three budget periods, the work progressed from high-temperature ORC component development and thermodynamic model validation to next-generation system design, working fluid transition, and techno-economic analysis. Key technical accomplishments include development and validation of a thermodynamic model capable of accurately predicting ORC performance across an expanded temperature and pressure envelope; successful identification and validation of low-global-warming-potential (GWP) working fluids—most notably R1233zd(E)—as viable replacements for R245fa; and demonstration of scalable ORC architectures suitable for integration with 1–20 MW class reciprocating engines. These advances enable flexible CHP configurations that can increase electrical output while maintaining high overall utilization of available thermal energy. The project also produced a clean-sheet design for a next-generation ORC system targeting substantially higher power output per unit, supported by detailed component selection, heat exchanger evaluation, and system-level modeling. Techno-economic analyses indicate that ORC-enabled flexible CHP systems can meet or exceed Department of Energy (DOE) efficiency targets while providing value to both facility operators and the electric grid.. Late-stage testing of the largest next-generation ORC prototype identified limitations related to pump net positive suction head (NPSH) requirements and condenser flooding under certain operating conditions. Although these issues constrained full validation of that configuration within the project timeframe, they provided clear and actionable design guidance for future system refinements. Importantly, validated modeling, smaller-scale testing, and working fluid evaluations confirmed the technical viability of the overall approach. In aggregate, this project met its core objectives by establishing validated design tools, de-risking key ORC technologies for CHP applications, and defining a credible pathway toward commercialization of flexible, high-efficiency CHP systems. The results form a strong foundation for continued development and deployment beyond the conclusion of the DOE-funded effort.

20 FOSSIL-FUELED POWER PLANTS↗

Design of Defensive Cybersecurity Architectures for Sodium-Cooled Fast Reactors

This report presents the design of defensive cybersecurity architectures (DCSAs) for Sodium-Cooled Fast Reactors (SFRs). A DCSA is a cybersecurity design feature that places systems into security zones in a graded approach according to the importance of the functions performed by the systems. DCSA design efforts for advanced reactors may commence as early as the system-level design phase. This design approach is consistent with the draft regulatory guide for advanced reactor cybersecurity programs (DG-5075) and enables advanced reactor designers to consider the effects of security-by design (SeBD) features on their DCSAs. Integration of DCSA design and other cybersecurity activities with the traditional design process as part of a SeBD framework may enable advanced reactor designers to improve the security posture of their plants while reducing implementation and operating costs. This report provides a DCSA template for an exemplar SFR and how the template may be optimized for a given SFR design.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Agent-Based, Bottom-Up Medium- and Heavy-duty Electric Vehicle Economics, Operation, Charging and Adoption (Research Performance Final Report)

This is the research performance final report for the project entitled: Agent-Based, Bottom-Up Medium- and Heavy-duty Electric Vehicle Economics, Operation, Charging and Adoption This project was able to achieve the DOE’s goals of developing new modeling tools to understand MDHD vehicle operation and adoption. The first modeling tool is a fleet-level techno-economic analysis model capable of estimating energy use and associated environmental and cost impacts for electrified and conventional vehicles of any MDHD vocation, using real-world cost and operations data, including approaches to optimizing schedules for charging and/or vehicle dispatch. The second modeling tool is a system-level, bottom-up, agent-based adoption model capable of generating geographically-resolved estimates of market projections for MDHD vehicles and charging infrastructure. These tools will be developed and published to serve dual purposes as analysis tools for researchers, and decision-support tools for decision makers within the MDHD system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Modeling Toolkit for Comparing AC and DC Electrical Distribution Efficiency in Buildings

Recently, there has been considerable research interest in the potential for DC distribution systems in buildings instead of the traditional AC distribution systems. Due to the need for performing power conversions between DC and AC electricity, DC distribution may provide electrical efficiency advantages in some systems. To support comparative evaluations of AC-only, DC-only, and hybrid AC/DC distribution systems in buildings, a new modeling toolkit called the Building Electrical Efficiency Analysis Model (BEEAM) was developed and is described in this paper. To account for harmonics in currents or voltages arising from nonlinear devices, the toolkit implements harmonic power flow, along with nonlinear device behavioral descriptions derived from empirical measurements. This paper describes the framework, network equations, device representations, and an implementation of the toolkit in an open source software package, including a component library and graphical interface for creating circuits. Simulations of electrical behavior and device and system efficiencies using the toolkit are compared with experimental measurements of a small office environment in a variety of operating and load configurations. A detailed analysis of uncertainty estimation is also provided. Key findings were that a comparison of predicted versus measured efficiencies and power losses in the validation testbed using the initial toolkit implementation predicted device- and system-level efficiencies with reasonably good accuracy under both balanced and unbalanced AC scenarios. An uncertainty analysis also revealed that the maximum estimated error for system efficiency across all scenarios was 3%, and measured and modeled system efficiency agreed within the experimental uncertainty in approximately half of the scenarios. Based on the correspondence between simulation and measurement, the toolkit is proposed by the authors as a potentially useful tool for comparing efficiency in AC, DC, and hybrid AC/DC distribution systems in buildings.

DC distribution↗

Dataset of Generative AI Workload Power Profiles

This dataset provides a collection of high-resolution (5/10 Hz or every 0.2/0.1 seconds) power consumption profiles for generative artificial intelligence (GenAI) workloads executed on NLR's High Performance Computing (HPC) platform Kestrel. The dataset also includes examples of representative whole-facility power profiles generated using a bottom-up, event-driven, data center energy model . This dataset is designed to support research in energy modeling, infrastructure planning, energy system integration, and sustainability analysis for AI-driven computing systems. The dataset captures time-resolved electrical power measurements across a diverse set of configurations, including variations in job type (inference vs. training), workload (LLM vs. image generation), datasets, and number of compute nodes. Power traces are provided in a standardized format and include both raw/instantaneous and aggregated files. Each profile is accompanied by metadata describing workload parameters, enabling reproducibility and cross-study comparison. The dataset is intended for use in applications such as data center infrastructure planning, energy modeling, demand response and grid impact studies, and development and validation of system-level simulation tools. By making these workload-specific power profiles publicly available, this dataset aims to address the current lack of open, empirical energy data for generative AI systems and to facilitate transparent, reproducible research on the energy and environmental impacts of large-scale AI deployment. If you use this dataset, please cite the associated publication: Vercellino et al., “Measurement of Generative AI Workload Power Profiles for Whole-Facility Data Center Infrastructure Planning,” arXiv:2604.07345 (2026).

97 MATHEMATICS AND COMPUTING↗