Search NASASearch

SEARCH · Search NASA

Results for “techniques: image processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Chasing ghosts: characterization of artifact generation in coded aperture decoding due to experimental implementation

Coded aperture imaging is a form of lensless aperture imaging that projects multiple overlapping images of the source onto the detector, enhancing signal strength, which is advantageous for low-flux sources or high-resolution imaging. This technique requires decoding of the detector signal to reconstruct the original source, which involves convolving the detector data with the aperture pattern. When the signal is from a centered point source, the reconstructed source image is known as the point spread function (PSF). A clean PSF without artifacts is a Dirac delta function [Appl. Opt. 20, 1858 (1981)]. This paper examines the robustness of the decoding process against variations in experimental tolerances by analyzing artifact growth in the reconstructed PSF. We illustrate the effects of incorrect magnification, rotation, and detector size and find that aperture–detector rotational misalignment about the imaging axis is the most sensitive parameter, with significant artifact generation occurring with angular offsets of less than one degree. We discuss compensation methods for imperfect aperture placement, finding that small detector sizes produce uncompensatable artifact generation, and compare theoretical predictions with experimental PSF measurements of a rank , 6.8 mm thick (less than one mean free path) coded aperture with a 3.5 mm cell size, conducted at the MegaJOuLe Neutron Imaging Radiography dense plasma focus [IEEE Trans. Plasma Sci. 49, 3299 (2021)] using a 2.45 MeV neutron source. Based on our findings, we recommend using magnified coded apertures in the under-sampled regime, which allows for the inclusion of fiducial markers to characterize aperture–detector rotational offsets and the addition of mechanical coupling, where possible, to constrain rotational and magnification offsets.

Selwood, M. P. [Lawrence Livermore National Labora

Enabling Bipolar Membrane Manufacturing Using Microscopy

Bipolar membranes (BPMs) used for water treatment suffer from interface instabilities, causing premature failure and decreased performance. Recent research has highlighted the impacts of membrane morphology on mechanical behavior and performance. Improved material performance of thin film membranes requires enhanced transport properties coupled with better control of the mechanical characteristics to avoid premature failure of the film. Thus, morphology is a key parameter when developing and evaluating novel membrane materials. Microscopy offers unique advantages for nano-scale characterization of thin film membrane interfaces and morphologies. In this study, the interface junction of BPMs was evaluated using scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDX). BPMs were fabricated using (1) hot pressing lamination, (2) bench-scale solution casting, and (3) roll-to-roll sequential casting (R2R). Both commercial and in-house fabricated ion exchange membranes were used in the BPMs. The BPMs were comprised of a cation exchange membrane and an anion exchange membrane with a catalyst layer sandwiched in between. Cross sectional SEM and EDX images of the membrane interface junction were compared among the different fabrication techniques and materials. The bench cast catalyst layers were nonuniform compared to the R2R and hot pressed membranes, demonstrating the importance of precise catalyst application conditions. Different thicknesses of the BPMs and individual membrane layers revealed that polymer solution concentration needs to be optimized during manufacturing. This work shows that microscopy can identify key processing parameters that affect BPM interface junction quality at the microscale to enable manufacturing of high performance BPMs.

36 MATERIALS SCIENCE

Enabling Roll-to-Roll Manufacturing of Bipolar Membranes Using Microscopy

Bipolar membranes (BPMs) used for water treatment suffer from interface instabilities, causing premature failure and decreased performance. Recent research has highlighted the impacts of membrane morphology on mechanical behavior and performance. Improved material performance of thin film membranes requires enhanced transport properties coupled with better control of the mechanical characteristics to avoid premature failure of the film. Thus, morphology is a key parameter when developing and evaluating novel membrane materials. Microscopy offers unique advantages for nano-scale characterization of thin film membrane interfaces and morphologies. In this study, the interface junction of BPMs was evaluated using scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDX). BPMs were fabricated using (1) hot pressing lamination, (2) bench-scale solution casting, and (3) roll-to-roll sequential casting (R2R). Both commercial and in-house fabricated ion exchange membranes were used in the BPMs. The BPMs were comprised of a cation exchange membrane and an anion exchange membrane with a catalyst layer sandwiched in between. Cross sectional SEM and EDX images of the membrane interface junction were compared among the different fabrication techniques and materials. The bench cast catalyst layers were nonuniform compared to the R2R and hot pressed membranes, demonstrating the importance of precise catalyst application conditions. Different thicknesses of the BPMs and individual membrane layers revealed that polymer solution concentration needs to be optimized during manufacturing. This work shows that microscopy can identify key processing parameters that affect BPM interface junction quality at the microscale to enable manufacturing of high performance BPMs.

36 MATERIALS SCIENCE

Super Resolving Unrolled Neural Networks for Remote Sensing

In remote sensing systems, the capabilities of the system are constrained by the complex interactions between size, weight, and power (SWAP) of potential designs. In electro-optical (EO) systems, examples of these critical parameters include the system’s sensitivity and resolution. Those parameters can be increased by ever larger optical apertures and focal planes but at the cost of more SWAP. Multi-image super resolution (MISR) techniques allow resolution to be enhanced via computation rather than more sophisticated optical hardware. These algorithms combine multiple images together into a single, higher resolution image, trading temporal resolution and computation for spatial resolution. Fielded MISR techniques, such as Drizzle, can require several hundred images to create a single super resolved image, implying reduced temporal resolution, increased data acquisition load, and limiting mission applications. Iterative techniques, such as model-based image reconstruction and compressive sensing, have been shown to create super resolved images using fewer images than Drizzle. They do this by posing an optimization problem that balances accuracy between a highly accurate physical model and an image model. In the case of super resolution, the physical model is defined by the relation between low resolution input images and the desired high resolution output image. The image model encodes some assumptions about the super resolved image. These assumptions are meant to suppress reconstruction artifacts that arise due to deterministic physical model error, stochastic measurement noise, and potential undersampling. In practice, the performance of iterative methods are limited by imaging models compatible with optimization. Deep learning-based methods can effectively learn image models of arbitrary complexity, but lack the theoretical explainability and robustness of iterative techniques. Consensus equilibrium (CE) generalizes the iterative techniques beyond optimization, enabling blackbox algorithms such as traditional and neural image denoisers to be used as the image model. CE-based approaches retain much of the explainability and robustness of iterative techniques while allowing the expressiveness of machine learning image models to be used. Additionally, by unrolling iterations of CE with an embedded image denoiser, the image denoiser can be further trained and specialized to the specific application with potentially higher quality reconstructions. Under this project, we demonstrated the feasibility of training an unrolled neural network based upon CE. While we didn’t train one, we showed that the CE process is differentiable and its gradient can be tractably computed. We also explored the usage of a variants of CE akin to generative neural works. Most importantly, we applied the CE framework to a number of problems including non-blind deconvolution, upsampling, single-image super resolution, MISR, event-based sensing, and saturated deconvolution. Our MISR prototype creates high quality reconstructions with an order of magnitude fewer images than previous approaches and, critically, produces these reconstructions fast enough for practical usage.

47 OTHER INSTRUMENTATION

High average-flux laser-driven neutron source

Laser-driven neutron generation is an attractive alternative to more established methods for compact, short-pulse-duration neutron sources with applications in medical science, material science and imaging. Despite extensive investigation of various techniques, achieving performance comparable to nuclear reactors or conventional accelerators remains challenging. In this work, we generate a stable, high-repetition-rate laser-driven neutron source reaching a record average flux of 7.8 × 10 7 n/sr/s, improving on other existing laser-based sources by more than one order of magnitude. Our approach is based on a two-step process where electrons are accelerated to relativistic energies via laser wakefield acceleration (LWFA), and subsequently generate neutrons through Bremsstrahlung emission followed by photonuclear reactions in a tungsten converter. Experimental results, supported by Monte Carlo simulations, show a neutron flux of 3.0 × 10 7 n/cm 2 /s near the target, on par with some compact accelerator-based neutron sources. Additionally, a direct comparison with the target-normal sheath acceleration (TNSA) pitcher-catcher scheme, performed on the same laser system, reveals a significantly higher total neutron yield of 3.9 × 10 8 neutrons per shot, outperforming the TNSA scheme by several orders of magnitude. These findings represent a significant advancement towards the development of practical laser-driven neutron sources and highlight the advantages of LWFA-based neutron generation for future applications.

Vallières, Simon [Institut National de la Recherch

Understanding Formation of Irradiation-Induced Defects through 4D-STEM, Electron Tomography, and WBDF-STEM

A major challenge in advancing nuclear materials for next-generation fission and proposed fusion reactors is to comprehensively understand the formation of irradiation-induced defects. Here it is essential to correlate the evolution of irradiation-induced defects and the degradation of mechanical properties, as they collectively dictate the material's lifespan and ensure nuclear safety. Scanning transmission electron microscopy (STEM) based techniques have emerged as indispensable tools for irradiation-induced defect characterization, offering high spatial resolution imaging and chemical analysis, such as electron energy loss spectroscopy (EELS) and energy dispersive X-ray spectroscopy (EDXS). These techniques have been effectively used to obtain an atomic-scale view of the defect structure. Recent advances in electron microscopy, particularly in 4D-STEM, offer detailed insight into microstructural evolution by capturing full 2D diffraction patterns at every pixel position. Using high-speed direct electron detectors, this technology generates a four-dimensional dataset, overcoming the limitations of traditional STEM imaging.

36 MATERIALS SCIENCE

Unraveling the origin of air-stability in single-crystalline layered oxide positive electrode materials

Single-crystalline Ni-rich layered oxides present compelling advantages over conventional polycrystalline counterparts toward large-scale applications, including enhanced mechanical stability and higher energy density. Nevertheless, the deleterious effects of air exposure, which is inevitable in industrial processing, on their structure and electrochemical performance remain poorly understood. Herein, we reveal that air exposure is more detrimental to the electrochemical performance of single-crystalline layered oxide positive electrodes than polycrystalline counterparts. It is found that air-induced surface structural distortions are primarily responsible for the electrochemical performance decay of single-crystalline samples rather than the generally believed surface residual lithium. Leveraging multiscale diffraction and imaging techniques, we identify an undesirable structural transition to a metastable O1* phase, which introduces substantial lattice defects and localized strain concentrations within the layered structure. These adverse structural evolutions compromise structural integrity and promote crack initiation during electrochemical cycling, ultimately accelerating capacity fade. Our findings provide critical insights into the air-induced degradation mechanisms and emphasize the urgent need for developing effective stabilization strategies to facilitate the commercial implementation of single-crystalline Ni-rich positive electrodes.

36 MATERIALS SCIENCE

Solution processed high aspect ratio ultra-long vertically well-aligned ZnO nano scintillators for potential X-ray imaging applications

We report the photon (PL), electron (CL) and X-ray (XEL) induced luminescence characteristics of high aspect ratio ultra-long (~ 50 µm) ZnO nanorods (NRs) and discuss the potential for fast X-ray detection based on the consistent and efficient visible emission (~ 580 nm) from ZnO NRs. Nanostructured ZnO scintillators were rearranged to form a vertically well-aligned NR design in order to help light absorption and coupling resulting in luminescent and fast scintillation properties. The design of the nanorod array combines the key advantages of a low-cost growth technique together with environmentally friendly and widely available materials. A low temperature hydrothermal method was adopted to grow ZnO NRs in one cycle growth and their structural, optical and X-ray scintillation properties were investigated. The relatively short (~ 10 µm) ZnO NRs emitting in the near-band-edge region were found to be almost insensitive to X-rays. On the other hand, the higher XEL response of long ZnO NRs, which is a key parameter for evaluation of materials to be used as scintillators for high quality X-ray detection and imaging, along with a decay time response in the order of ns confirmed promising scintillation properties for fast and high-resolution X-ray detector applications.

47 OTHER INSTRUMENTATION

Direct Imaging of Hydrogen‐Driven Dislocation and Strain Field Evolution in a Stainless Steel Grain

Hydrogen embrittlement (HE) poses a significant challenge to the durability of materials used in hydrogen production and utilization. Disentangling the competing nanoscale mechanisms driving HE often relies on simulations and electron-transparent sample techniques, limiting experimental insights into hydrogen-induced dislocation behavior in bulk materials. This study employs in situ Bragg coherent X-ray diffraction imaging to track three-dimensional (3D) dislocation and strain field evolution during hydrogen charging in a bulk grain of austenitic 316 stainless steel. Tracking a single dislocation reveals hydrogen-enhanced mobility and relaxation, consistent with dislocation dynamics simulations. Subsequent observations reveal dislocation unpinning and climb processes, likely driven by osmotic forces. Additionally, nanoscale strain analysis around the dislocation core directly measures hydrogen-induced elastic shielding. These findings experimentally validate theoretical predictions and offer mechanistic insights into hydrogen-driven dislocation behavior. The quantified nanoscale phenomena serve as critical inputs for multiscale modeling frameworks to predict bulk material responses and accelerate the development of HE-resistant alloys.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND

Integration and Demonstration of Monitoring, Modeling, and Prediction of DV-1 Amendment Performance at the Bench Scale: DV-1 Amendment Demonstration

During fiscal years 2024 and 2025, the U.S. Department of Energy’s Hanford Field Office commissioned Pacific Northwest National Laboratory to conduct applied research aimed at reducing the cost, time, and uncertainty associated with in situ treatment of vadose zone contaminants at the Hanford Site. This report outlines the integration of three key research efforts into a meso-scale demonstration designed to advance field-scale solutions that aim to (1) optimize the delivery of chemical amendments to contaminated soils, (2) reduce uncertainty in amendment delivery performance assessment using advanced monitoring techniques, and (3) provide real-time insights into when and where amendment-induced precipitation reactions occur in the subsurface. To achieve these objectives, the tank-scale (~ 1 cubic meter) Geophysical Imaging of Flow and Transport (GIFT) system was developed. GIFT enables experimental testing of amendment delivery while incorporating automated multi-modal monitoring approaches, including pressure measurements, direct fluid sampling, and remote time-lapse geophysical imaging. The data generated from these monitoring techniques will serve as inputs for a generative artificial-intelligence-driven digital twin – a numerical simulation model designed to honor observed data while quantifying uncertainty in simulation accuracy. Using this simulator, researchers will refine an amendment injection strategy to maximize delivery efficiency within a low-permeability soil zone. Monitoring data will be interpreted through simulated outputs to enhance understanding of the injection process. The efficacy of this integrated approach will be evaluated through direct sampling at the conclusion of the experiment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W

Monte Carlo N-Particle Transport Performance of Predicting Digital Radiographic IQI Inspection

The identification of porosity, geometric noncompliance, and other defect types are critical to the qualification of materials and components. X-ray radiographic nondestructive testing is a common industrial inspection method for process quality control and component qualification and certification. Digital radiography provides a quick and efficient alternative when compared to traditional film-based inspection. The quality of radiographic inspection is dependent on equipment specifications, such as the source spot size and detector pixel size, and the specific parameters selected for use for the radiographic technique. To evaluate if an x-ray system and technique is sufficient for a given requirement, a radiographic image quality indicator (IQI) can be used. Radiographic IQIs in hard to machine materials or hard to manufacture defects can be time consuming and expensive to manufacture. This study was conducted to evaluate current Savannah River National Laboratory (SRNL) x-ray imaging systems with a custom tantalum IQI and using Monte Carlo simulations to predict the performance of future systems. The tantalum IQI was tested using a Siefert Isovolt 420 keV x-ray tube with a Perkin Elmer XRD 1611 flat panel with 100-micron pixels. Using the Monte Carlo N-Particle transport software, the radiographic tally was used to simulate the photon flux through an identical tantalum IQI. These simulations provided a benchmark as to the best theoretical identification on a given system using our tantalum IQI. The simulations were refined to match SRNL’s current systems’ noise levels, leading to confidence in their ability to predict the performance of other systems that may be purchased and deployed in the future at the Savannah River Site. Future studies will be conducted to prove this research can be extended to artificially evaluate the ability for systems to identify critical defect sizes through x-ray radiographic inspection, drastically reducing the cost and time burdens of producing high-fidelity radiographic test articles.

digital X-ray radiography

Unraveling the Nature of Lasing Emission from Hybrid Silicon Nitride and Colloidal Nanocrystal Photonic Crystals with Low Refractive Index Contrast

Silicon nitride is used for its low optical loss and high thermal stability, making it a suitable platform for visible-light applications in integrated photonic devices. However, its application has been limited due to inefficient light emission, a problem addressed by integrating various types of light emitters onto the platform. In particular, the integration of solution-processable colloidal nanocrystals (NCs) as optical gain materials onto the silicon nitride platform is a promising route but requires a more solid theoretical footing. By leveraging 2D surface-emitting photonic crystal structures combined with NCs, we effectively confine and manipulate light to achieve lasing from green to red. Building on this, we model the light–matter interactions of the low index contrast NC/nitride platform, validated by extensive experimental validations through Fourier imaging techniques, revealing the full photonic band structure and showing clear mode congestion. Finally, these comprehensive studies confirm the potential of hybrid NC-based structures for fully integrated on-chip laser applications and indicate routes for further improvement.

BIC Lasing

Rapid Optimization of Total Variation with Applications in Imaging, Additive Manufacturing, and Qualification

Total Variation optimization penalizes the gradient of a control variable or state. While this work focuses on image processing in particular, it has also found applications in inverse problems and topology optimization. In image processing, the goal is to maintain faithfulness to the original image while denoising and/or deblurring. Additionally, bilevel optimization over the spatially varying regularization weights can illuminate interfaces such as damage regions and other anomalies. We will address two fundamental challenges with TV-optimization: (i) the typical slow convergence of existing TV-optimization methods, and (ii) the selection of spatially varying TV parameters to promote interface detection. Additionally, we will apply such techniques to image data collected in additive manufacturing. In said context, stochasticity in build events induces flaws in the manufactured piece, compromising the integrity of said part. There is a critical need for in-situ monitoring to spot anomalies once they form, and in this setting we apply our total variation and hyperparameter solvers. We will develop a customized algorithm based on for extreme-scale TV-optimization that achieves super-linear or quadratic-convergence, a critical property for real-time, image-by-image analysis. A worst-case outcome is a preprocessing step that enhances image quality in-situ, specifically for out-of-focus and noisy images.

36 MATERIALS SCIENCE

Optimized manufacturing process for multilayer two-dimensional focusing mirrors in laboratory X-ray applications

Recent advances in laboratory X-ray applications require high-performance optical components that achieve exceptional imaging resolution and beam uniformity within compact experimental setups. Montel mirrors have become a preferred solution due to their unique dual-reflection focusing mechanism and a space-efficient design. Here, in this study, we present an effective manufacturing process for producing Montel mirrors tailored to focus laboratory X-ray beams. The mirrors were fabricated from single-crystal silicon substrates, chosen for their high mechanical stability and compatibility with precision polishing techniques. Our approach begins with the integration of a deterministic chemo-mechanical polishing (CMP)-based pre-shaping step followed by ion beam figuring (IBF), significantly improving manufacturing efficiency. Subsequently, our custom-developed advanced metrology and IBF techniques were employed for fabricating an off-axis, elliptical cylinder Montel mirror system with a 6-mrad total slope, with stringent optical specifications. While post-IBF processes, including multilayer coating, dicing, and gluing, introduced minor surface errors, yet their impact on performance remained negligible. The Montel mirrors manufactured with the optimized process exhibited significantly improved beam uniformity and a reduced focal spot size. These findings validate our approach as a viable solution for high-precision Montel mirror fabrication and facilitate further advancements in laboratory X-ray applications.

36 MATERIALS SCIENCE

Black-box optimization of CT acquisition and reconstruction parameters: a reinforcement learning approach

Protocol optimization is critical in Computed Tomography (CT) for achieving desired diagnostic image quality while minimizing radiation dose. Due to the inter-effect of influencing CT parameters, traditional optimization methods rely on the testing of exhaustive combinations of these parameters. This poses a notable limitation due to the impracticality of exhaustive parameter testing. This study introduces a novel methodology leveraging Virtual Imaging Trials (VITs) and reinforcement learning to more efficiently optimize CT protocols. Computational phantoms with liver lesions were imaged using a validated CT simulator and reconstructed with a novel CT reconstruction Toolkit. The optimization parameter space included tube voltage, tube current, reconstruction kernel, slice thickness, and pixel size. The optimization process was done using a Proximal Policy Optimization (PPO) agent which was trained to maximize the Detectability Index (d’) of the liver lesion for each reconstructed image. Results showed that our reinforcement learning approach found the absolute maximum d’ across the test cases while requiring 79.7% fewer steps compared to an exhaustive search, demonstrating both accuracy and computational efficiency, offering a efficient and robust framework for CT protocol optimization. The flexibility of the proposed technique allows for use of varying image quality metrics as the objective metric to maximize for. Our findings highlight the advantages of combining VIT and reinforcement learning for CT protocol management.

Fenwick, David [Duke University Medical Center]

Online thermal profile prediction for large format additive manufacturing: A hybrid CNN-LSTM based approach

Large format additive manufacturing (LFAM) is an advanced 3D printing technique that efficiently fabricates large-scale components through a layer-by-layer extrusion and deposition process. Accurate surface layer temperature monitoring is essential to prevent manufacturing failures and ensure final product quality. Traditional physics-based offline approaches for simulating thermal behavior are often inefficient and complex, posing challenges on real-time, in-situ monitoring. Here, to address this, we propose a data-driven hybrid CNN-LSTM model to predict sequential thermal images of arbitrary length using real-time infrared thermal imaging. In this approach, a Convolutional Neural Networks (CNN) is trained offline to capture spatial features, reduce dimensional complexity, and enhance time efficiency, while a stacked Long Short-Term Memory (LSTM) is applied online to capture temporal information for improved prediction of future thermal behavior in subsequent printing layers. Model performance is evaluated using MSE, SSIM, and PSNR metrics and is benchmarked against stacked LSTM and convolutional LSTM models, demonstrating superior accuracy and applicability. Additionally, to mitigate noise from moving extruders and gantry backgrounds in thermal images, a fine-tuned semantic segmentation model is implemented offline to extract printing geometry, enabling precise temperature tracking along the tool path for further thermal analysis. The frameworks developed in this study significantly advance temperature monitoring, thermal analysis, and in-situ manufacturing control for LFAM, bridging the gap between theoretical modeling and practical application.

Geometry extraction

Imaging Bragg Edge Analysis TooLs for Engineering Structures (iBeatles)

The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL) provides pulsed neutrons with energies varying from epithermal to cold. In preparation for VENUS, the neutron imaging beamline to be located at beam port 10, we have performed a series of experiments focused on wavelength-dependent radiography and computed tomography for a broad range of applications, from materials science to biological tissues.One of the time-of-flight (TOF) techniques that is of interest to the scientific community is the 2-dimensional mapping of phases and average crystalline plane orientation in samples both ex-situ and during applied stresses such as tensile loading and heating. This technique is known as Bragg edgeimaging and relies on the identification of changes of transmission values, fitting of the edge to measure its displacement, and thus identify the shift in lattice parameter due to stresses. One of the challenges of TOF imaging measurements is the amount of data and the inability to observe Bragg edge shifts in real time during an experiment. Thus, we have been focusing on creating a Python-based interface that allows fast data processing and instantaneous mapping and fitting of the Bragg edges, and their evolution through time. Python libraries and Jupyter notebooks have been implemented to facilitate decision making during an experiment. The advantage of the notebooks is the possibility to guide an experiment as they can quickly process and display Bragg edge data. These notebooks can be used independently, or can be combined in a Python Graphical User Interface (GUI) tool called iBeatles. This interface permits visualization and fitting of the Bragg edges, and ultimately back-projects the fitting results onto the radiographs to display a strain map. Assuming data collection has sufficient statistics, the strain mapping analysis can be performed on a pixel-by-pixel basis. This development is a step forward toward a better user experience at the future VENUS beamline in terms of live feedback and productivity. Analysis that used to take days of switching between different applications can now be done in minutes within the

Bilheux, JeanChristophe [Oak Ridge National Labora

Utilization of Data Augmentation Techniques in Automated Inspection Systems for Defect Detection in Metals With Limited Data

Accurate identification of defects on metal surfaces is of great interest to many industry sectors, such as the automotive and aerospace industries. In contrast to conventional manual inspection techniques, recent automated inspection systems employ deep learning models trained to detect defects rapidly and precisely. The development of these models often requires a substantial image dataset to acquire adequate knowledge of defect features and enhance their predictive accuracy. When data is limited, augmentation techniques are often used to improve the precision and accuracy of defect detection systems. This study examined the prediction performance of two object detection models, namely Faster Region‐based Convolutional Neural Network (Faster R‐CNN) and You Only Look Once version 8 (YOLOv8), to identify dent defects in limited images of cast iron cylinder head surfaces. The original image set contains 46 images with 563 dents. To overcome limited data availability, common image augmentation techniques along with a copy‐paste method were applied. Results show that standard augmentation improved YOLOv8 accuracy by 8.00% and average precision (AP) by 3.00%. On the other hand, the copy‐paste technique achieved a 20.00% increase in accuracy and a 1% increase in AP with just 200 synthetic dents. Furthermore, these results provide support for using the copy‐paste augmentation strategy to enhance defect detection performance, with a limited dataset, contributing to more accurate defect identification in remanufacturing processes.

36 MATERIALS SCIENCE