Search NASA⌕ Search

SEARCH · Search NASA

Results for “voltage regulators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Development and performance of pulse-width-modulated static inverter and converter modules

Pulse-width-modulated inverter and converter modules are being developed for modular aerospace electrical power systems. The modules, rate 2.5 kilowatts per module and 10-minute - 150-percent overload, operate from 56 volts dc. The converter module provides two output voltages: a nominal link voltage of 200 volts dc when used with the inverter, and 150 volts dc to a load bus when used separately. The inverter module output is 400-hertz, sinusoidal, three-phase, 120/208 volts. Tests of breadboard models with standard parts and integrated circuits show rated power efficiencies of 71.4 and 85.1 percent and voltage regulation of 5 and 3.1 percent for inverter and converter modules, respectively. Sine-wave output distortion is 0.74 percent.

Pittman, P. F.↗

Silicon-controlled-rectifier square-wave inverter with protection against commutation failure

The square-wave SCR inverter that was designed, built, and tested includes a circuit to turn off the inverter in case of commutation failure. The basic power stage is a complementary impulse-commutated parallel inverter consisting of only six components. The 400-watt breadboard was tested while operating at + or - 28 volts, and it had a peak efficiency of 95.5 percent at 60 hertz and 91.7 percent at 400 hertz. The voltage regulation for a fixed input was 3 percent at 60 hertz. An analysis of the operation and design information is included.

Birchenough, A. G.↗

Improvements in and test results for the 2 to 15 kilowatt Brayton cycle electrical subsystem

The electrical subsystem of the 2- to 15-kW Brayton power conversion system consists of the auxiliary electrical equipment required for an integrated, self-contained system. For the last 2 years the electrical subsystem has been undergoing extensive tests. The first year of testing resulted in determining the performance characteristics of the electrical subsystem. During the second year several significant changes and improvements were investigated. An inverter designed for motor starting the alternator performed successfully. Some of the changes that have been made are a new alternator speed pickup, which is independent of the alternator output voltage; new, more efficient power supplies for the control system; and a volts-per-hertz reference for the alternator voltage regulator. Test data were taken on the temperature distribution of the electrical subsystem at startup conditions over a cold-plate temperature range of 25 to -50 C.

Vrancik, J. E.↗

Solar electric propulsion thrust subsystem development

The Solar Electric Propulsion System developed under this program was designed to demonstrate all the thrust subsystem functions needed on an unmanned planetary vehicle. The demonstration included operation of the basic elements, power matching input and output voltage regulation, three-axis thrust vector control, subsystem automatic control including failure detection and correction capability (using a PDP-11 computer), operation of critical elements in thermal-vacuum-, zero-gravity-type propellant storage, and data outputs from all subsystem elements. The subsystem elements, functions, unique features, and test setup are described. General features and capabilities of the test-support data system are also presented. The test program culminated in a 1500-h computer-controlled, system-functional demonstration. This included simultaneous operation of two thruster/power conditioner sets. The results of this testing phase satisfied all the program goals.

Masek, T. D.↗

Performance of the electrical controls for the Mini-Brayton system

The design theory and performance of a breadboard of the proposed Mini-Brayton electrical control system is presented. The Mini-Brayton is a nuclear isotope powered dynamic power conversion system. Testing was performed with an electronic simulation of a turbine alternator. Data on the voltage regulation, speed control, power consumption, reliability and transient response are presented for the breadboard.

Birchenough, A. G.↗

Power conversion in electrical networks

Aspects of dc to dc conversion were studied in terms of a class of switching voltage regulators from a stability viewpoint. Background concepts of nonlinear system theory were considered, including the problem of obtaining suitable realizations for a class of positive operators. It is shown that the state evolution equations for a power conversion network are in general of bilinear form, and that the theory of lie groups and lie algebras is useful in analyzing such systems. The feedback stabilization of a class of bilinear systems whose state space is a manifold is also discussed.

Wood, J. R.↗

Design and performance of a no-single-failure control system for the mini-Brayton power conversion system

The control system consists of the ac-dc conversion, voltage regulation, speed regulation through parasitic load control, and overload control. A no-single-failure configuration was developed to attain the required reliability for a 10-year design life of unattended operation. The design principles, complete schematics, and performance are reported. Testing was performed on an alternator simulator pending construction of the actual Mini-Brayton alternator.

Brichenough, A. G.↗

Evaluation of a high power inverter for potential space applications

The ADM-006 inverter discussed utilizes a unique method of using power switching circuits to produce three-phase low harmonic content voltages without any significant filtering. This method is referred to as the power center approach to inverter design and is explained briefly. The results are presented of tests performed by MSFC to evaluate inverter performance, especially when required to provide power to nonlinear loads such as half or full wave rectified loads with capacitive filtering. Test preocedures and results are described. These tests show that the power center inverter essentially met or exceeded all of claims excluding voltage regulation (3.9 percent versus specified 3.3 percent) and would be a good candidate for high power inverter applications such as may be found on Space Station, Spacelab, etc.

Guynes, B. V.↗

Phase substitution of spare converter for a failed one of parallel phase staggered converters

Failure detection and substitution of a spare module is provided in a system having a plurality of phase staggered modules connected in parallel to deliver regulated voltage from an unregulated source. Phase control signals applied to the active converter modules are applied to the spare module through NOR gates associated with and disabled by the power output of respective modules such that failure of any one enables its phase control signal to be applied to the spare module, thus controlling the spare module to operate in the phase position of the failed module. A NAND gate detects when any one active module fails and enables a gate in the spare module, thus activating the spare module.

Mclyman, W. T.↗

On-orbit performance of the 12 GHz, 200 watt transmitter experiment package for CTS

Performance characteristics from on-orbit tests of the Transmitter Experiment Package (TEP) for the Communications Technology Satellite (CTS) are presented. The TEP consists of a Power Processing System (PPS), an Output Stage Tube (OST), and a Variable Conductance Heat Pipe System (VCHPS), all of which are described. The OST is a coupled-cavity traveling-wave tube with a multistage depressed collector and a stepped velocity-tapered slow-wave structure for efficiency enhancement. It has an RF output power of 240 W and an overall efficiency of 51.5% at a center band frequency of 12.080 GHz. The PPS provides the required operating voltages, regulation, control, and protection for the OST. It has a measured dc-dc conversion efficiency of 86.5% to 88.5%. The VCHPS consists of a fin radiator and three dual-artery stainless steel heat pipes using methanol and a mixture of inert gases. Test results presented include efficiencies, RF output power, frequency response, and performance with single and multiple (two) carriers frequency-modulated by video signals.

Alexovich, R. E.↗

Performance of the 12GHz, 200 watt transmitter experiment package for the Hermes satellite

Performance characteristics from on-orbit tests of the Transmitter Experiment Package (TEP) for the Hermes Satellite are presented. The TEP consists of a Power Processing System (PPS), an Output Stage Tube (OST) and a Variable Conductance Heat Pipe System (VCHPS), all of which are described. The OST is a coupled-cavity Traveling Wave Tube (TWT) with a Multistage Depressed Collector (MDC) and a stepped velocity-tapered slow wave structure for efficiency enhancement. It has an RF output power of 233 watts and overall efficiency of 50.75 percent at a center band frequency of 12.080 GHz. The PPS provides the required operating voltages, regulation, control and protection for the OST. The VCHPS consists of a fin radiator and three dual-artery stainless steel heat pipes using methanol and a mixture of inert gases. Test results presented include efficiencies, RF output power and body current. A discussion of thermal anomalies which occurred is presented.

Alexovich, R. E.↗

Performance of the 12 GHz, 200 watt Transmitter Experiment Package for the Hermes Satellite

Performance characteristics from on-orbit tests of the Transmitter Experiment Package (TEP) for the Hermes Satellite are presented. The tests were conducted from February 8, 1976 through August 8, 1977. The TEP consists of a Power Processing System (PPS), an Output Stage Tube (OST) and a Variable Conductance Heat Pipe System (VCHPS), all of which are described. The OST is a coupled-cavity traveling wave tube with a multistage depressed collector and a stepped velocity-tapered slow wave structure for efficiency enhancement. It has an RF output power of 233 W and overall efficiency of 50.75% at a center band frequency of 12.080 GHz. The PPS provides the required operating voltages, regulation, control and protection for the OST. The VCHPS consists of a fin radiator and three dual-artery stainless steel heat pipes using methanol and a mixture of inert gases. Test results presented include efficiencies, RF output power and body current. A discussion of thermal anomalies which occurred is presented.

Alexovich, R. E.↗

Diode step stress testing program for JANTX1N759A

The effect of power/temperature step stress when applied to a variety of voltage regulating diodes manufactured by Texas Instruments and Siemens was investigated. Test requirements are described and results are tabulated. Failure modes are discussed.

Source record↗

Battery life test using reconditioning

A discussion is presented on nickel cadmium battery life tests using reconditioning and some comparative tests not using reconditioning. The discussion is aimed at the program application part of the testing. The goals of the program were to get an increased utilization out of the battery system in geosynchronous orbit. An attempt was made to push the depth of discharge operation up around 80 to 85 percent and the intent with the reconditioning program was to extend this type of utilization out towards a 10-year life and attune the voltage regulation.

Sparks, R. H.↗

Effects of periodic discharges

Periodic capacity checks are assessed as well as the effects of periodic discharges on the cycle life and the performance of cells during the cycle life. Topics discussed include the effect of the amount of electrolyte on cell capacity at 35 C; battery design for spacecraft; electrolyte starvation theory; battery separator degradation; negative electrode stability; voltage regulation; operating temperatures; and integration of reconditioning systems using microprocessors.

Ford, F. E.↗

Recent advances in redox flow cell storage systems

Several features which were conceived and incorporated into complete redox systems that greatly enhanced its ability to be kept in proper charge balance, to be capable of internal voltage regulation, and in general be treated as a true multicell electrochemical system rather than an assembly of single cells that were wired together, were discussed. The technology status as it relates to the two application areas of solar photovoltaic/wind and distributed energy storage for electric utility applications was addressed. The cost and life advantages of redox systems were also covered.

Thaller, L. H.↗

A power extension package /PEP/ for the Shuttle Orbiter

A concept for solar array augmentation of the power normally provided by the Shuttle Orbiter fuel cells in support of payloads is discussed. Justification for the use of solar arrays rather than additional cryogenic fuel kits for extension of on-orbit stay time is presented. This is followed by a description of the array power system and an examination of its interfaces with the existing Orbiter fuel cell system. The system produces 29 kW total with 14 kW allocated to the Orbiter and 15 kW to payloads and permits an increase in on-orbit mission duration from 6 to approximately 20 days at 21 kW with four cryo kits. It is capable of producing full output in diverse vehicle orientations since the array is deployed and oriented by the Orbiter remote manipulator system (RMS). Power produced by the arrays is reduced to 32.25 to 32.5 volts by pulse-width-modulated buck voltage regulators to force the Orbiter fuel cells into an idle mode during the sunlighted portions of the orbit.

Ness, H. C.↗

Satellite control of electric power distribution

An L-band frequencies satellite link providing the medium for direct control of electrical loads at individual customer sites from remote central locations is described. All loads supplied under interruptible-service contracts are likely condidates for such control, and they can be cycled or switched off to reduce system loads. For every kW of load eliminated or deferred to off-peak hours, the power company reduces its need for additional generating capacity. In addition, the satellite could switch meter registers so that their readings automatically reflected the time of consumption. The system would perform load-shedding operations during emergencies, disconnecting large blocks of load according to predetermined priorities. Among the distribution operations conducted by the satellite in real time would be: load reconfiguration, voltage regulation, fault isolation, and capacitor and feeder load control.

Bergen, L.↗