Search NASA⌕ Search

SEARCH · Search NASA

Results for “source injection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

MULTIBAND NONTHERMAL RADIATIVE PROPERTIES OF HESS J1813-178

The source HESS J1813-178 was detected in a survey of the inner Galaxy in TeV {gamma}-rays, and a composite supernova remnant (SNR) G12.8-0.0 was identified in the radio band to be associated with it. The pulsar wind nebula (PWN) embedded in the SNR is powered by an energetic pulsar PSR J1813-1749, which was recently discovered. Whether the TeV {gamma}-rays originate from the SNR shell or the PWN is currently uncertain. We theoretically investigate the multiwavelength nonthermal radiation from the composite SNR G12.8-0.0. The emission from the particles accelerated in the SNR shell is calculated by applying a semianalytical method to the nonlinear diffusive shock acceleration mechanism. In the model, the magnetic field is self-generated via resonant streaming instability, and the dynamical reaction of the field on the shock is taken into account. Based on a model which couples the dynamical and radiative evolution of a PWN in a non-radiative SNR, the dynamics and the multiband emission of the PWN are investigated. The particles are injected with the spectrum of a relativistic Maxwellian plus a power-law high-energy tail with an index of -2.5. Our results indicate that the radio emission from the shell can be reproduced well as synchrotron radiation of the electrons accelerated by the SNR shock; with an interstellar medium number density of 1.4 cm{sup -3} for the remnant, the {gamma}-ray emission from the SNR shell is insignificant and the observed X-rays and very high energy (VHE) {gamma}-rays from the source are consistent with the emission produced by electrons/positrons injected in the PWN via synchrotron radiation and inverse Compton scattering, respectively; the resulting {gamma}-ray flux for the shell is comparable to the detected one, only with a relatively larger density of about 2.8 cm{sup -3}. The VHE {gamma}-rays of HESS J1813-178 can be naturally explained to mainly originate from the nebula, although the contribution of the SNR shell becomes significant with a denser ambient medium.

79 ASTRONOMY AND ASTROPHYSICS↗

An analysis of the influence of impurities on fast particle attenuation and on fast ion spectral shape in LHD

Neutral particle fluxes measured by neutral particle analyzers can provide information about the ion temperature as well as the non-Maxwellian anisotropic ion distribution tails from neutral beam injection and ion cyclotron radio frequency heating. In the case of multidirectional diagnostics employing high resolution atomic energy spectrometers, the neutral atomic flux source is not localized in contrast to pellet charge exchange or diagnostic neutral beam methods. The correct interpretation of such measurements from plasma in a complex toroidally asymmetric geometry, like that of LHD, requires careful numerical modeling of the neutral flux formation. Previously a measured neutral flux calculation scheme was developed and was used for the LHD geometry and a suitable analytic expression for ionization cross sections {sigma}{sub s}{sup (z)}(E,n{sub e},T{sub e},Z{sub eff}) of impurities was formulated by Janev et al. [Nucl. Fusion 29, 2125 (1989)]. In this paper, the attenuation of fast particles by impurities is incorporated into the neutral flux calculation scheme and the influence of impurities on the calculated neutral flux spectra is shown. Finally, the behavior of the calculated and experimental suprathermal particle distributions is compared for pure hydrogen and for argon impurity seeded plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a radio-frequency ion beam source for fast-ion studies on the large plasma device

A helium ion beam source (23 kV/2.0 A) has been constructed for studying fast-ion physics in the cylindrical magnetized plasma of the large plasma device (LAPD). An inductive RF source produces a 10{sup 19} m{sup -3} density plasma in a ceramic dome. A multi-aperture, rectangular (8 cm x 8 cm) three-grid system extracts the ion beam from the RF plasma. The ion beam is injected at a variety of pitch angles with Alfvenic speeds in the LAPD. The beam current is intense enough to excite magnetic perturbations in the ambient plasma. Measurements of the ion beam profile were made to achieve an optimum beam performance and a reliable source operation was demonstrated on the LAPD.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Decon2LS: An Open-Source Software Package for Automated Processing and Visualization of High Resolution Mass Spectrometry Data

Data generated from liquid chromatography coupled to high-resolution mass spectrometry (LC-MS)-based studies of a biological sample can contain large amounts of biologically significant information in the form of proteins, peptides, and metabolites. Interpreting these data uses the mass spectra to infer masses and abundances of biomolecules injected into the instrument. Because of the inherent complexity of mass spectral patterns produced by these biomolecules, the analysis is significantly enhanced by using visualization capabilities to inspect and confirm results. In this paper we describe Decon2LS, an open-source software package for automated processing and visualization of high-resolution MS data. Drawing extensively on algorithms developed over the last ten years for ICR2LS, Decon2LS packages the algorithms as a rich set of modular, reusable processing classes for performing diverse functions such as raw data readers, routine peak finding, theoretical isotope distribution modelling, and deisotoping. Because the source code is openly available, these functionalities can now be used to build derivative applications in relatively fast manner. In addition, Decon2LS provides an extensive set of visualization tools, such as high performance chart controls.

59 BASIC BIOLOGICAL SCIENCES↗

Multiple dopant injection system for small rocket engines

The Diagnostics Test Facility (DTF) at NASA's Stennis Space Center (SSC) was designed and built to provide a standard rocket engine exhaust plume for use in the research and development of engine health monitoring instrumentation. A 1000 lb thrust class liquid oxygen (LOX)-gaseous hydrogen (GH2) fueled rocket engine is used as the subscale plume source to simulate the SSME during experimentation and instrument development. The ability of the DTF to provide efficient, and low cost test operations makes it uniquely suited for plume diagnostic experimentation. The most unique feature of the DTF is the Multiple Dopant Injection System (MDIS) that is used to seed the exhaust plume with the desired element or metal alloy. The dopant injection takes place at the fuel injector, yielding a very uniform and homogeneous distribution of the seeding material in the exhaust plume. The MDIS allows during a single test firing of the DTF, the seeding of the exhaust plume with up to three different dopants and also provides distilled water base lines between the dopants. A number of plume diagnostic-related experiments have already utilized the unique capabilities of the DTF.

Sakala, G. G.↗

H{sup -} beam transport experiments in a solenoid low energy beam transport

The Front End Test Stand (FETS) is located at Rutherford Appleton Laboratory and aims for a high current, fast chopped 3 MeV H{sup -} ion beam suitable for future high power proton accelerators like ISIS upgrade. The main components of the front end are the Penning ion source, a low energy beam transport line, an radio-frequency quadrupole (RFQ) and a medium energy beam transport (MEBT) providing also a chopper section and rebuncher. FETS is in the stage of commissioning its low energy beam transport (LEBT) line consisting of three solenoids. The LEBT has to transport an H{sup -} high current beam (up to 60 mA) at 65 keV. This is the injection energy of the beam into the RFQ. The main diagnostics are slit-slit emittance scanners for each transversal plane. For optimizing the matching to the RFQ, experiments have been performed with a variety of solenoid settings to better understand the actual beam transport. Occasionally, source parameters such as extractor slit width and beam energy were varied as well. The paper also discusses simulations based on these measurements.

43 PARTICLE ACCELERATORS↗

A high-performance electron beam ion source

At Brookhaven National Laboratory, a high current Electron Beam Ion Source (EBIS) has been developed as part of a new preinjector that is under construction to replace the Tandem Van de Graaffs as the heavy ion preinjector for the RHIC and NASA experimental programs. This preinjector will produce milliampere-level currents of essentially any ion species, with q/A {ge} 1/6, in short pulses, for injection into the Booster synchrotron. In order to produce the required intensities, this EBIS uses a 10A electron gun, and an electron collector designed to handle 300 kW of pulsed electron beam power. The EBIS trap region is 1.5 m long, inside a 5T, 2m long, 8-inch bore superconducting solenoid. The source is designed to switch ion species on a pulse-to-pulse basis, at a 5 Hz repetition rate. Singly-charged ions of the appropriate species, produced external to the EBIS, are injected into the trap and confined until the desired charge state is reached via stepwise ionization by the electron beam. Ions are then extracted and matched into an RFQ, followed by a short IH Linac, for acceleration to 2 MeV/A, prior to injection into the Booster synchrotron. An overview of the preinjector is presented, along with experimental results from the prototype EBIS, where all essential requirements have already been demonstrated. Design features and status of construction of the final high intensity EBIS is also be presented.

43 PARTICLE ACCELERATORS↗

ELECTRON AND PROTON ACCELERATION DURING THE FIRST GROUND LEVEL ENHANCEMENT EVENT OF SOLAR CYCLE 24

High-energy particles were recorded by near-Earth spacecraft and ground-based neutron monitors (NMs) on 2012 May 17. This event was the first ground level enhancement (GLE) of solar cycle 24. In this study, we try to identify the acceleration source(s) of solar energetic particles by combining in situ particle measurements from the WIND/3DP, GOES 13, and solar cosmic rays registered by several NMs, as well as remote-sensing solar observations from SDO/AIA, SOHO/LASCO, and RHESSI. We derive the interplanetary magnetic field (IMF) path length (1.25 {+-} 0.05 AU) and solar particle release time (01:29 {+-} 00:01 UT) of the first arriving electrons by using their velocity dispersion and taking into account contamination effects. We found that the electron impulsive injection phase, indicated by the dramatic change in the spectral index, is consistent with flare non-thermal emission and type III radio bursts. Based on the potential field source surface concept, modeling of the open-field lines rooted in the active region has been performed to provide escape channels for flare-accelerated electrons. Meanwhile, relativistic protons are found to be released {approx}10 minutes later than the electrons, assuming their scatter-free travel along the same IMF path length. Combining multi-wavelength imaging data of the prominence eruption and coronal mass ejection (CME), we obtain evidence that GLE protons, with an estimated kinetic energy of {approx}1.12 GeV, are probably accelerated by the CME-driven shock when it travels to {approx}3.07 solar radii. The time-of-maximum spectrum of protons is typical for shock wave acceleration.

79 ASTRONOMY AND ASTROPHYSICS↗

Research Activities At The RCNP Cyclotron Facility

The Research Center for Nuclear Physics (RCNP) cyclotron cascade system has been operated to provide high quality beams for various experiments. In order to increase the physics research opportunities, the Azimuthally Varying Field (AVF) cyclotron facility was upgraded recently. A flat-topping system and an 18-GHz superconducting Electron Cyclotron Resonance (ECR) ion source were introduced to improve the beam's quality and intensity. A new beam line was installed to diagnose the characteristics of the beam to be injected into the ring cyclotron and to bypass the ring cyclotron and directly transport low energy beams from the AVF cyclotron to experimental halls. A separator is equipped to provide RI beams produced by fusion reactions at low energy and by projectile fragmentations at high energy. Development has continued to realize the designed performance of these systems.

43 PARTICLE ACCELERATORS↗

An isotope identification injection study with GammaTracker

GammaTracker is a portable handheld radioisotope identifier using position sensitive CdZnTe detectors. High confidence isotope identification is possible on GammaTracker owing to the system's relatively high energy resolution and count rate sensitivity. A study was undertaken to evaluate the isotope identification performance of a prototype unit. Background and source spectra for various nuclides were measured and then randomly sampled to simulate various integration times and source intensities. The resulting spectral data sets were then run through the isotope identification algorithm to determine the probability of detection and the false alarm rate for each nuclide. The process was repeated for various isotope identification input parameters until an optimized set was achieved. This paper presents results from the injection study.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beam simulation studies of ECR beam extraction and low energy beam transport for FRIB

To meet the beam power requirements of 400 kW at the fragmentation target for facility for Rare Isotope Beams (FRIB), simultaneous acceleration of two-charge states should be used for heavier ions. These intense multi-charged ion beams will be produced by a 28 GHz electron cyclotron resonance (ECR) ion source at a high voltage of 35 kV. After extraction, the ion beam will be pre-accelerated to 12 keV/u with a 50 kV platform, transported down to an achromatic charge state selection (CSS) system followed by a vertical transport line, and then injected into a radio frequency quadrupole accelerator. The TRACK code developed at ANL is used to perform the simulations of the ECR beam extraction and low energy beam transport for FRIB. In this study, we include the magnetic field of ECR ion source into simulations. Different initial beam conditions as well as different space charge neutralization levels are tested for the ECR beamline. The beam loss in CSS system and the corresponding protective measures are discussed. The detailed results about the beam dynamic simulation and beam loss in CSS system will be presented in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of reduction in porosity and permeability with depth on storage capacity and injectivity in deep saline aquifers: A case study from the Mount Simon Sandstone aquifer

The Upper Cambrian Mount Simon Sandstone is recognized as a deep saline reservoir that has significant potential for geological sequestration in the Midwestern region of the United States. Porosity and permeability values collected from core analyses in rocks from this formation and its lateral equivalents in Indiana, Kentucky, Michigan, and Ohio indicate a predictable relationship with depth owing to a reduction in the pore structure due to the effects of compaction and/or cementation, primarily as quartz overgrowths. The regional trend of decreasing porosity with depth is described by the equation: Φ(d) = 16.36×e -0.00039*d , where Φ is the porosity and d is the depth in m. The decrease of porosity with depth generally holds true on a basinwide scale. Bearing in mind local variations in lithologic and petrophysical character within the Mount Simon Sandstone, the source data that were used to predict porosity were utilized to estimate the pore volume available within the reservoir that could potentially serve as storage space for injected CO 2 . The potential storage capacity estimated for the Mount Simon Sandstone in the study area, using efficiency factors of 1%, 5%, 10%, and 15%, is 23,680, 118,418, 236,832, and 355,242 million metric tons of CO 2 , respectively.

58 GEOSCIENCES↗

Observation of synergy between lower hybrid waves at two frequencies in EAST

Synergistic effects between two frequencies of lower hybrid (LH) waves—operating at 2.45 and 4.6 GHz—were observed in experiment on EAST for the first time. At low density (n_e,lin ≈ 2.0 × 10^19m^−3), simultaneous injection of a 65/35 mix of 2.45 GHz/4.6 GHz power achieved an LHCD efficiency that was 25% higher than what should be expected from the linear combination of the two sources. The experiment was interpreted with time-dependent simulations, using the equilibrium and transport solver TRANSP, coupled with the ray-tracing code GENRAY and the Fokker-Planck solver CQL3D. For each discharge, profiles of current and hard x-ray from simulation and measurement agree within uncertainties. An examination of the electron distribution function indicates that the LH synergy is supported by the increased width of the LH resonance plateau in the simultaneous injection case compared to independent injection.

Lower hybrid synergy↗

N- and P-Type Cluster Source

We describe our newest ClusterIon registered source, and show detailed data for B{sub 18}H{sub x}{sup +}, C{sub 7}H{sub 7}{sup +}, C{sub 16}H{sub x}{sup +}, P{sub 4}{sup +}, and As{sub 4}{sup +} beams. These species are derived from both low-temperature solids and gaseous sources. 2D beam profiles are presented, along with mass spectra, beam current performance, and long-term beam reproducibility. The data were collected using the injection stage of a commercial ion implanter equipped with a 120 degree analyzer magnet. Beam profiles at magnet entrance and exit planes were produced using a specially designed 2D profiler. Beam currents were measured after mass analysis using a Faraday cup over an effective energy range of 200 eV to 10 keV.

43 PARTICLE ACCELERATORS↗

A Finite Element Model for Simulation of Carbon Dioxide Sequestration

We present a hydro-mechanical model, followed by stress, deformation, and shear-slip failure analysis for geological sequestration of carbon dioxide (CO2). The model considers the poroelastic effects by taking into account of the two-way coupling between the geomechanical response and the fluid flow process. Analytical solutions for pressure and deformation fields were derived for a typical geological sequestration scenario in our previous work. A finite element approach is introduced here for numerically solving the hydro-mechanical model with arbitrary boundary conditions. The numerical approach was built on an open-source finite element code Elmer, and results were compared to the analytical solutions. The shear-slip failure analysis was presented based on the numerical results, where the potential failure zone is identified. Information is relevant to the prediction of the maximum sustainable injection rate or pressure. The effects of caprock permeability on the fluid pressure, deformation, stress, and the shear-slip failure zone were also quantitatively studied. It was shown that a larger permeability in caprock and base rock leads to a larger uplift but a smaller shear-slip failure zone.

54 ENVIRONMENTAL SCIENCES↗

NEAR-INFRARED IMAGING POLARIMETRY OF THE SERPENS CLOUD CORE: MAGNETIC FIELD STRUCTURE, OUTFLOWS, AND INFLOWS IN A CLUSTER FORMING CLUMP

We made deep near-infrared (JHKs) imaging polarimetry toward the Serpens cloud core, which is a nearby, active cluster forming region. The polarization vector maps show that the near-infrared reflection light in this region mainly originates from SVS 2 and SVS 20, and enable us to detect 24 small infrared reflection nebulae associated with young stellar objects. Polarization measurements of near-infrared point sources indicate an hourglass-shaped magnetic field, of which the symmetry axis is nearly perpendicular to the elongation of the C{sup 18}O (J = 1-0) or submillimeter continuum emission. The bright part of C{sup 18}O (J = 1-0), submillimeter continuum cores as well as many Class 0/I objects are located just toward the constriction region of the hourglass-shaped magnetic field. Applying the Chandrasekhar and Fermi method and taking into account the recent study on the signal integration effect for the dispersion component of the magnetic field, the magnetic field strength was estimated to be {approx}100 {mu}G, suggesting that the ambient region of the Serpens cloud core is moderately magnetically supercritical. This suggests that the Serpens cloud core first contracted along the magnetic field as an elongated cloud, which is perpendicular to the magnetic field, and that the central part then contracted across the magnetic field due to the high density in the central region of the cloud core, where star formation is actively continuing. Comparison of this magnetic field with previous observations of molecular gas and large-scale outflows suggests a possibility that the cloud dynamics are controlled by the magnetic field, protostellar outflows, and gravitational inflows. Furthermore, the outflow energy injection rate appears to be larger than the dissipation rate of the turbulent energy in this cloud, indicating that the outflows are the main source of turbulence and that the magnetic field plays an important role both in allowing the outflow energy to escape from the central region of the cloud core and enabling the gravitational inflows from the ambient region to the central region. These characteristics appear to be in good agreement with the outflow-driven turbulence model and imply the importance of the magnetic field to continuous star formation in the center region of the cluster forming region.

79 ASTRONOMY AND ASTROPHYSICS↗

Usefulness of specific calibration coefficients for gamma-emitting sources measured by radionuclide calibrators in nuclear medicine

Purpose: In nuclear medicine, the activity of a radionuclide is measured with a radionuclide calibrator that often has a calibration coefficient independent of the container type and filling. Methods: To determine the effect of the container on the accuracy of measuring the activity injected into a patient, The authors simulated a commercial radionuclide calibrator and 18 container types most typically used in clinical practice. The instrument sensitivity was computed for various container thicknesses and filling levels. Monoenergetic photons and electrons as well as seven common radionuclides were considered. Results: The quality of the simulation with gamma-emitting sources was validated by an agreement with measurements better than 4% in five selected radionuclides. The results show that the measured activity can vary by more than a factor of 2 depending on the type of container. The filling level and the thickness of the container wall only have a marginal effect for radionuclides of high energy but could induce differences up to 4%. Conclusions: The authors conclude that radionuclide calibrators should be tailored to the uncertainty required by clinical applications. For most clinical cases, and at least for the low-energy gamma and x-ray emitters, measurements should be performed with calibration coefficients specific to the container type.

61 RADIATION PROTECTION AND DOSIMETRY↗

A velocity map imaging detector with an integrated gas injection system

We present the design of a velocity map imaging spectrometer where the target gas is injected from a capillary that is integrated in the repeller plate of the ion optics assembly that drives electrons/ions formed by ionization or dissociation to a two-dimensional detector. The geometry of this design allows the use of gas densities in the interaction region that are two to three orders of magnitude higher than the densities that are used in standard velocity map imaging spectrometers, making the detector suitable for working with weak light sources such as newly developed attosecond pulse sources, or (quasi-)cw sources such as synchrotrons. In a test where monoenergetic photoelectrons were generated by six-photon ionization of Xe (utilizing the second harmonic of a neodymium doped Nd:YAG), the kinetic energy resolution of the spectrometer was found to be {delta}E/E=1.8%. This number was found to be in good agreement with Monte Carlo simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗