Search NASA⌕ Search

SEARCH · Search NASA

Results for “Image Processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Photogrammetry: Develop methods for detecting deviations from expected geometry of components in a glovebox environment (Lawrence Livermore National Laboratory Aging and Lifetimes Program FY23, Milestone 8651, Grading Criterion #4)

Measurements in glovebox environments are challenging to conduct. Currently deployed techniques are time consuming and provide limited information. These limitations make current disposition and future assessments of products challenging. In FY23 we developed methods for detecting deviations of components in a glovebox environment that address these shortcomings by rapidly collecting information-dense measurements. Conducted tests demonstrate that camera pose (position and orientation) can be derived for images utilized in the photogrammetry process. This information, in conjunction with common image processing techniques, enables automated detection and size estimation of surface features. First, image processing is used to identify marks, or localized regions, that standout from the surrounding area. Then, the physical size of the region can be estimated because scale can be determined for photogrammetry images. Development of this methods shows that photogrammetry can identify measurable deviations from expected geometries. Although measurement error when using this technique through a glovebox window still needs to be reduced, this capability shows promise for eliminating or reducing the use of tedious manual measurements.

42 ENGINEERING↗

Universal liquid sample device and process for high resolution transmission electron microscope imaging and multimodal analyses of liquid sample materials

Liquid sample imaging devices and processes are disclosed for high resolution TEM imaging and multimodal analyses of liquid sample materials in situ under high vacuum that are compatible with standard type TEM chip membranes and TEM sample holders allowing TEM liquid sample imaging to be performed wherever a TEM instrument is accessible and at a substantially reduced cost compared to prior art systems and approaches.

36 MATERIALS SCIENCE↗

CALIBRATED ULTRA FAST IMAGE SIMULATIONS FOR THE DARK ENERGY SURVEY

Image simulations are becoming increasingly important in understanding the measurement process of the shapes of galaxies for weak lensing and the associated systematic effects. For this purpose we present the first implementation of the Monte Carlo Control Loops (MCCL), a coherent framework for studying systematic effects in weak lensing. It allows us to model and calibrate the shear measurement process using image simulations from the Ultra Fast Image Generator (UFig) and the image analysis software SExtractor. We apply this framework to a subset of the data taken during the Science Verification period (SV) of the Dark Energy Survey (DES). We calibrate the UFig simulations to be statistically consistent with one of the SV images, which covers ∼0.5 square degrees. We then perform tolerance analyses by perturbing six simulation parameters and study their impact on the shear measurement at the one-point level. This allows us to determine the relative importance of different parameters. For spatially constant systematic errors and point-spread function, the calibration of the simulation reaches the weak lensing precision needed for the DES SV survey area. Furthermore, we find a sensitivity of the shear measurement to the intrinsic ellipticity distribution, and an interplay between the magnitude-size and the pixel value diagnostics in constraining the noise model. This work is the first application of the MCCL framework to data and shows how it can be used to methodically study the impact of systematics on the cosmic shear measurement.

79 ASTRONOMY AND ASTROPHYSICS↗

Real-time atomic-resolution imaging of crystal growth process in water by phase modulation atomic force microscopy at one frame per second

Recent advancement in dynamic-mode atomic force microscopy (AFM) has enabled its operation in liquid with atomic-scale resolution. However, its imaging speed has often been too slow to visualize atomic-scale dynamic processes. Here, we propose a method for making a significant improvement in the operation speed of dynamic-mode AFM. In this method, we use a wideband and low-latency phase detector with an improved algorithm for the signal complexification. We demonstrate atomic-scale imaging of a calcite crystal growth process in water at one frame per second. The significant improvement in the imaging speed should enable various studies on unexplored atomic-scale interfacial processes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-E-J-243: Possibility of Exposure Dose Reduction of Cone-Beam Computed Tomography in An Image Guided Patient Positioning System by Using Various Noise Suppression Filters

Purpose: To investigate the possibility of exposure dose reduction of the cone-beam computed tomography (CBCT) in an image guided patient positioning system by using 6 noise suppression filters. Methods: First, a reference dose (RD) and low-dose (LD)-CBCT (X-ray volume imaging system, Elekta Co.) images were acquired with a reference dose of 86.2 mGy (weighted CT dose index: CTDIw) and various low doses of 1.4 to 43.1 mGy, respectively. Second, an automated rigid registration for three axes was performed for estimating setup errors between a planning CT image and the LD-CBCT images, which were processed by 6 noise suppression filters, i.e., averaging filter (AF), median filter (MF), Gaussian filter (GF), bilateral filter (BF), edge preserving smoothing filter (EPF) and adaptive partial median filter (AMF). Third, residual errors representing the patient positioning accuracy were calculated as an Euclidean distance between the setup error vectors estimated using the LD-CBCT image and RD-CBCT image. Finally, the relationships between the residual error and CTDIw were obtained for 6 noise suppression filters, and then the CTDIw for LD-CBCT images processed by the noise suppression filters were measured at the same residual error, which was obtained with the RD-CBCT. This approach was applied to an anthropomorphic pelvic phantom and two cancer patients. Results: For the phantom, the exposure dose could be reduced from 61% (GF) to 78% (AMF) by applying the noise suppression filters to the CBCT images. The exposure dose in a prostate cancer case could be reduced from 8% (AF) to 61% (AMF), and the exposure dose in a lung cancer case could be reduced from 9% (AF) to 37% (AMF). Conclusion: Using noise suppression filters, particularly an adaptive partial median filter, could be feasible to decrease the additional exposure dose to patients in image guided patient positioning systems.

60 APPLIED LIFE SCIENCES↗

FEbeam: Cavity and electron emission data conversion, processing, and analysis. A freeware toolkit for rf injectors

FEbeam is an all-in-one field emission data processing interface with the capability to analyze the field emission cathode performance in an rf injector by extracting the field enhancement factor, local field, and effective emission area from the Fowler–Nordheim equations. It also has the capability of processing beam imaging micrographs using its sister software, FEpic. Furthermore, the current version of FEbeam was designed for the Argonne Cathode Test-stand of the Argonne Wakefield Accelerator facility switch yard. With slight modifications, FEbeam could work for many rf field emission injectors. This software is open-source and can be found at GitHub.

43 PARTICLE ACCELERATORS↗

New surface characterization tools for alumina based refractory material exposed to cavitation - Image analysis and pattern recognition approach

Highlights: • Surface degradation was monitored via mass loss measurement. • Observation of surface damage destruction was done using image analysis. • Shape parameters of surface defects change during cavitation. • Shape parameters changes are correlated to mass loss measurements. - Abstract: The aim of this study was to examine the influence of cavitation erosion on the morphology of defects formed on the surfaces of alumina-based materials. The alumina-based samples were exposed to cavitation erosion for 42 min. The damages that occurred were monitored at predefined time intervals by measuring the mass loss and observing the sample surfaces. Digital images of surfaces were processed using an image analysis software package to define morphological characteristics of the damages occurred. The calculated morphological parameters were subjected to analysis by pattern recognition techniques to correlate the appearance of particular morphological characteristics with the behavior of the material during cavitation erosion. The newly established method in describing cavitation erosion which uses pattern recognition approach for treatments of morphological parameters calculated for damages by image analysis tools gave the results efficient for material characterization as the traditional one.

36 MATERIALS SCIENCE↗

Few-view cone-beam CT reconstruction with deformed prior image

Purpose: Prior images can be incorporated into the image reconstruction process to improve the quality of subsequent cone-beam CT (CBCT) images from sparse-view or low-dose projections. The purpose of this work is to develop a deformed prior image-based reconstruction (DPIR) strategy to mitigate the deformation between the prior image and the target image. Methods: The deformed prior image is obtained by a projection-based registration approach. Specifically, the deformation vector fields used to deform the prior image are estimated through iteratively matching the forward projection of the deformed prior image and the measured on-treatment projections. The deformed prior image is then used as the prior image in the standard prior image constrained compressed sensing (PICCS) algorithm. A simulation study on an XCAT phantom and a clinical study on a head-and-neck cancer patient were conducted to evaluate the performance of the proposed DPIR strategy. Results: The deformed prior image matches the geometry of the on-treatment CBCT more closely as compared to the original prior image. Consequently, the performance of the DPIR strategy from few-view projections is improved in comparison to the standard PICCS algorithm, based on both visual inspection and quantitative measures. In the XCAT phantom study using 20 projections, the average root mean squared error is reduced from 14% in PICCS to 10% in DPIR, and the average universal quality index increases from 0.88 in PICCS to 0.92 in DPIR. Conclusions: The present DPIR approach provides a practical solution to the mismatch problem between the prior image and target image, which improves the performance of the original PICCS algorithm for CBCT reconstruction from few-view or low-dose projections.

60 APPLIED LIFE SCIENCES↗

System and method for remote detection and location of gas leaks

A system for monitoring for a gas leak from a gas containing structure is disclosed. The system includes a lens that directs an image of a scene of interest through an optical filter onto a detector. The filter is associated with the lens and the filter has one or more passbands that passes wavelengths which match one or more emission or reflectively wavelengths of the gas being monitored. A detector receives the image after the image passes through the lens and the filter. The detector generates image data representing the scene including the gas containing structure. A processor is configured to process the image data by executing machine executable code stored on a memory. The machine executable code processes the image data to identify turbulence flows in the image data such that turbulence flow indicates a gas leak, and generate and send an alert in response to the identification of a turbulence flow.

O'Neill, Mary D.↗

Graphene milling dynamics during helium ion beam irradiation

We explore the potential of the Helium Ion Microscope (HIM) as a tool for direct-write patterning of graphene and describe the underlying processes of graphene milling with image data processing. Controlled helium ion irradiation of suspended graphene conducted while monitoring the mill in-situ revealed the localized formation of nanopores, their growth, and coalescence. We also explore the effects of defects on the milling dynamics, and show that pre-exposed membranes rupture by cracking and rapid crack propagation at the edges of the growing defects. The mechanism for the rupturing process is described by local defect formation by excessive irradiation of helium ions, dictated by the scanning direction of the beam. As a result, these findings enrich fundamental understanding of the graphene milling process with a helium ion beam that, is necessary for high-resolution and high throughput patterning of graphene with nanoscale precision.

36 MATERIALS SCIENCE↗

A small-volume, high-throughput approach for surface tension and viscosity measurements of liquid fuels

An ongoing effort looking at bioblendstocks to function as drop-in replacements or blending components for gasoline has identified a large number of candidate fuels. This work documents an approach for rapid screening of candidate fuels using relatively small sample sizes ($\mathcal{O}(\mu\,{\rm l})$) that targets two key physical properties of liquid fuels—surface tension and viscosity. The approach utilizes shape oscillation dynamics of single droplets generated by a piezo-electric device and their decay over time. Strobed imaging of the oscillation process is used along with image processing, edge detection, and data analysis to capture the decay of the oscillation over time. The time constant of the decay process along with oscillation frequency are then used to estimate viscosity and surface tension using a theory for small amplitude droplet oscillations. Measurements are obtained for primary reference fuels (isooctane and n-heptane) as well as candidate fuels from four bio-derived functional groups of interest. Measurement results for surface tension and viscosity are correlated with literature data as well as measurements from standard reference instruments. The measurement results show that the droplet oscillation based approach is capable of reproducing surface tension and viscosity values for the tested fuels within deviations of 7% and 13% respectively from literature data. Results are obtained using an average of 5 µl per fuel within about 20 s, thus demonstrating a small-volume, high-throughput approach that can be used for screening of candidate bioblendstock fuels.

09 BIOMASS FUELS↗

The Hyper Suprime-Cam software pipeline

Here in this article, we describe the optical imaging data processing pipeline developed for the Subaru Telescope’s Hyper Suprime-Cam (HSC) instrument. The HSC Pipeline builds on the prototype pipeline being developed by the Large Synoptic Survey Telescope’s Data Management system, adding customizations for HSC, large-scale processing capabilities, and novel algorithms that have since been reincorporated into the LSST codebase. While designed primarily to reduce HSC Subaru Strategic Program (SSP) data, it is also the recommended pipeline for reducing general-observer HSC data. The HSC pipeline includes high-level processing steps that generate coadded images and science-ready catalogs as well as low-level detrending and image characterizations.

79 ASTRONOMY AND ASTROPHYSICS↗

Intrinsic Feature Motion Tracking

Subject motion during 3D medical scanning can cause blurring and artifacts in the 3D images resulting in either rescans or poor diagnosis. Anesthesia or physical restraints may be used to eliminate motion but are undesirable and can affect results. This software measures the six degree of freedom 3D motion of the subject during the scan under a rigidity assumption using only the intrinsic features present on the subject area being monitored. This movement over time can then be used to correct the scan data removing the blur and artifacts. The software acquires images from external cameras or images stored on disk for processing. The images are from two or three calibrated cameras in a stereo arrangement. Algorithms extract and track the features over time and calculate position and orientation changes relative to an initial position. Output is the 3D position and orientation change measured at each image.

Goddard, Jr., James S.↗

Compressed video camera with a moving patterned disk

A high-speed video system is disclosed that includes a moving image absorbing disk at an image plane. The disk has a pattern that passes and blocks image data. The disk is located between an event and an image sensor, or reflects an image to the image sensor. The disk is rotated at a speed that matches the desired reconstructed image frame rate. The image sensor frame data is processed using image reconstruction techniques, such as the D-AMP or TWIST algorithm, to recover a time sequence of reconstructed images. Additional images can be reconstructed for each image sensor frame if some spatial resolution is sacrificed. For continuous video, the disk speed is adjusted to the sensor frame rate. For burst mode, a single sensor image is acquired and a short image sequence is reconstructed. This image capture system works with a variety of radiations, including infrared, light, UV and X-rays.

42 ENGINEERING↗

Evaluating User Errors and Temporal Trends in Marine Fish Communities Using 360-Degree Underwater Photography

The use of environmental DNA (eDNA) sampling has been proposed as a complementary method to monitor fish species in marine environments, offering a non-invasive and potentially more efficient approach to marine species observations. eDNA monitoring could be especially useful in and around sites targeted for marine energy generation as these regions need regular monitoring that would be impractical with traditional techniques. Before we can fully rely upon eDNA, we must first verify its accuracy against other proven methods, such as the use of underwater photography. In this study, I deployed a 360-degree camera in the tidal channel of Sequim Bay once a month during several hours overlapping slack tide. I investigated how having multiple people identify and count fish on underwater images could affect the overall results. Using chi square tests in R, I compared my fish identifications and counts to those made by another intern on the same images recorded in August. I found significant differences in the number of species identified and the total individual counts between the two different datasets. I also tested the statistical differences in both Shannon diversity and Pielou evenness indices between the August, September, and November camera deployments using a Hutcheson t-test. Only one significant difference was found in the Shannon index comparisons, and none were found between the Pielou evenness comparisons. These findings show that if multiple identifiers are used to process underwater images, quality control checks must be made to reduce the potential for error. This also points toward the possibility to leverage more advanced image analysis processes, such as automated image analysis software. The findings from this study also show that the dynamics of marine fish communities can vary over a few months; however, further analysis is needed to determine the extent of the seasonal changes in Sequim Bay.

59 BASIC BIOLOGICAL SCIENCES↗

Source shape estimation for neutron imaging systems using convolutional neural networks

Neutron imaging systems are important diagnostic tools for characterizing the physics of inertial confinement fusion reactions at the National Ignition Facility (NIF). In particular, neutron images give diagnostic information on the size, symmetry, and shape of the fusion hot spot and surrounding cold fuel. Images are formed via collection of neutron flux from the source using a system of aperture arrays and scintillator-based detectors. Currently, reconstruction of fusion source geometry from the collected neutron images is accomplished by solving a computationally intensive maximum likelihood estimation problem via expectation maximization. In contrast, it is often useful to have simple representations of the overall source geometry that can be computed quickly. In this work, we develop convolutional neural networks (CNNs) to reconstruct the outer contours of simple source geometries. We compare the performance of the CNN for penumbral and pinhole data and provide experimental demonstrations of our methods on both non-noisy and noisy data.

Machine learning, neutron imaging, source reconstr↗

Gamma Imaging Improvements for GrayQb™

SRNL’s Imaging, Robotics, and Radiation Systems Group has had several successful field deployments with the GrayQb™, a custom designed radiation mapping device. The GrayQb™ returned consistent radiation contour maps through its deployment and demonstrated its effectiveness in quickly and inexpensively capturing images of radiation hot spots. To process the images from the GrayQb™, the device must be recovered between each deployment. This is due to the GrayQb™’s use of Phosphor Storage Plates (PSPs), which are a standard X-ray imaging material in dentistry and oral applications. PSPs are highly sensitive to radiation; however, currently they must be processed through an external scanner. SRNL designed the GrayQb™ for radiation areas, and much effort is required to deploy and recover the GrayQb™. To reduce time and resources spent deploying and recovering the GrayQb™, SRNL is working to upgrade the device to read PSP images and transmit image data to an external location using an internal camera system eliminating the need to remove the PSP.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of scatter in digital mammography from use of Monte Carlo simulations and comparison to physical measurements

Purpose: Monte Carlo simulations were performed with the goal of verifying previously published physical measurements characterizing scatter as a function of apparent thickness. A secondary goal was to provide a way of determining what effect tissue glandularity might have on the scatter characteristics of breast tissue. The overall reason for characterizing mammography scatter in this research is the application of these data to an image processing-based scatter-correction program. Methods: MCNPX was used to simulate scatter from an infinitesimal pencil beam using typical mammography geometries and techniques. The spreading of the pencil beam was characterized by two parameters: mean radial extent (MRE) and scatter fraction (SF). The SF and MRE were found as functions of target, filter, tube potential, phantom thickness, and the presence or absence of a grid. The SF was determined by separating scatter and primary by the angle of incidence on the detector, then finding the ratio of the measured scatter to the total number of detected events. The accuracy of the MRE was determined by placing ring-shaped tallies around the impulse and fitting those data to the point-spread function (PSF) equation using the value for MRE derived from the physical measurements. The goodness-of-fit was determined for each data set as a means of assessing the accuracy of the physical MRE data. The effect of breast glandularity on the SF, MRE, and apparent tissue thickness was also considered for a limited number of techniques. Results: The agreement between the physical measurements and the results of the Monte Carlo simulations was assessed. With a grid, the SFs ranged from 0.065 to 0.089, with absolute differences between the measured and simulated SFs averaging 0.02. Without a grid, the range was 0.28–0.51, with absolute differences averaging −0.01. The goodness-of-fit values comparing the Monte Carlo data to the PSF from the physical measurements ranged from 0.96 to 1.00 with a grid and 0.65 to 0.86 without a grid. Analysis of the data suggested that the nongrid data could be better described by a biexponential function than the single exponential used here. The simulations assessing the effect of breast composition on SF and MRE showed only a slight impact on these quantities. When compared to a mix of 50% glandular/50% adipose tissue, the impact of substituting adipose or glandular breast compositions on the apparent thickness of the tissue was about 5%. Conclusions: The findings show agreement between the physical measurements published previously and the Monte Carlo simulations presented here; the resulting data can therefore be used more confidently for an application such as image processing-based scatter correction. The findings also suggest that breast composition does not have a major impact on the scatter characteristics of breast tissue. Application of the scatter data to the development of a scatter-correction software program can be simplified by ignoring the variations in density among breast tissues.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗