Simulation experiments for gamma-ray mapping of planetary surfaces: Scattering of high-energy neutrons

The concentration and distribution of certain elements in surface layers of planetary objects specify constraints on models of their origin and evolution. This information can be obtained by means of remote sensing gamma-ray spectroscopy, as planned for a number of future space missions, i.e., Mars, Moon, asteroids, and comets. To investigate the gamma-rays made by interactions of neutrons with matter, thin targets of different composition were placed between a neutron-source and a high-resolution germanium spectrometer. Gamma-rays in the range of 0.1 to 8 MeV were accumulated. In one set of experiments a 14-MeV neutron generator using the T(d,n) reaction as neutron-source was placed in a small room. Scattering in surrounding walls produced a spectrum of neutron energies from 14 MeV down to thermal. This complex neutron-source induced mainly neutron-capture lines and only a few scattering lines. As a result of the set-up, there was a considerable background of discrete lines from surrounding materials. A similar situation exists under planetary exploration conditions: gamma-rays are induced in the planetary surface as well as in the spacecraft. To investigate the contribution of neutrons with higher energies, an experiment for the measurement of prompt gamma radiation was set up at the end of a beam-line of an isochronous cyclotron.

Brueckner, J.↗

Preliminary NoMAD Results of the MUSIC Experiment

The Measurement of Uranium Subcritical and Critical (MUSiC) experiment was carried out from December 2020 through April 2021 at the National Criticality Experiments Research Center (NCERC). This measurement campaign featured bare configurations of the Rocky Flats highly-enriched uranium (HEU) shells, with each configuration having different numbers of these shells. The goal of the experiment was to test multiple neutron multiplicity detectors and measurement methods for a large range of neutron multiplication values, to see when the combination of detectors and methods break down as the configurations reach the delayed supercritical window. Adding subcritical integral benchmarks gives additional validation to nuclear data. These benchmarks provide additional parameters against which to validate the data. While critical benchmarks have just a single value, $K_{eff}$ , subcritical benchmarks can be used to infer multiple parameters. As an example, recent subcritical benchmarks utilizing the Hage-Cifarelli formalism have three quantities of interest ($R_{1}$, $R_{2}$, and $M_{L}$). This gives nuclear data evaluators additional data to use when performing their evaluations, and allows for these benchmarks to be useful for additional types of nuclear data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison Study of Upper Subcritical Limits Derived Using Sensitivity/Uncertainty Tools: Case Studies of U233-SOL-THERM-001-001, MIX-COMP-THERM-001-001, IEU-MET-FAST-002-001, LEU-COMP-THERM-001-001, LEU-SOL-THERM-004-001

Neutron transport methods used to establish subcriticality require validation by comparison to critical experiments considered to be benchmarks. Whisper is a sensitivity/uncertainty analysis tool developed to assist with the task of validation in nuclear criticality safety. Details on the Whisper methodology can be found in References 1-3 on the MCNP® reference collection website at https://mcnp.lanl.gov. Whisper-1.0 was originally developed in 2014 and used to assist with nuclear criticality safety validation at Los Alamos National Laboratory. Whisper was upgraded in 2016 to Whisper-1.1 and prepared for release with MCNP6.2 [References 3-5]. Whisper contains a library of over 1100 critical experiment benchmarks and quantifies neutronic similarity of an application to benchmarks in the library. Using highest similarity benchmarks, Whisper computes a calculational margin (CM) encompassing of the worst-case bias and bias uncertainty at a 99% confidence level for each application. In addition, portions of the margin of subcriticality (MOS) for nuclear data uncertainty and potential code errors are computed. The baseline upper subcritical limit (USL) computed by Whisper is comprised of the CM, MOS nuclear data , and MOS code errors . The Whisper baseline USL is absent a portion of the MOS due to the area of application, which is applied based upon judgment by the criticality safety analyst. An objective of this paper is to present the baseline USL, CM and portions of the MOS as computed by Whisper for comparison with similar sensitivity/uncertainty tools, such as those used by IRSN and ORNL. An initial comparison involved four critical experiment benchmarks: HEU-MET-FAST-013-001, HEU-SOLTHERM-001-008, PU-MET-FAST-022-001, AND PU-SOL-THERM-001-001, which have been documented in References 10-13. This study extends the comparison to include cases U233-SOL-THERM-001-001, MIX-COMP-THERM-001-001, IEU-MET-FAST-002-001, LEU-COMP-THERM-001-001, LEU-SOL-THERM- 004-001.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron Activation Foil and Thermoluminescent Dosimeter Responses to a Lead Reflected Pulse of the CEA Valduc SILENE Critical Assembly

This benchmark experiment was conducted as a joint venture between the US Department of Energy (DOE) and the French Commissariat à l'Energie Atomique (CEA). Staff at the Oak Ridge National Laboratory (ORNL) in the US and the Centre de Valduc in France planned this experiment. The experiment was conducted on October 13, 2010 in the SILENE critical assembly facility at Valduc. Several other organizations contributed to this experiment and the subsequent evaluation, including CEA Saclay, Lawrence Livermore National Laboratory (LLNL), the Y-12 National Security Complex (NSC), Babcock International Group in the United Kingdom, and Los Alamos National Laboratory (LANL). The goal of this experiment was to measure neutron activation and thermoluminescent dosimeter (TLD) doses from a source similar to a fissile solution critical excursion. The resulting benchmark can be used for validation of computer codes and nuclear data libraries as required when performing analysis of criticality accident alarm systems (CAASs). A secondary goal of this experiment was to qualitatively test performance of two CAAS detectors similar to those currently and formerly in use in some US DOE facilities. The detectors tested were the CIDAS MkX and the Rocky Flats NCD-91. The CIDAS detects gammas with a Geiger-Muller tube, and the Rocky Flats detects neutrons via charged particles produced in a thin 6 LiF disc, depositing energy in a Si solid-state detector. These detectors were being evaluated to determine whether they would alarm, so they were not expected to generate benchmark quality data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron Activation Foil and Thermoluminescent Dosimeter Responses to a Polyethylene Reflected Pulse of the CEA Valduc SILENE Critical Assembly

This benchmark experiment was conducted as a joint venture between the US Department of Energy (DOE) and the French Commissariat à l'Energie Atomique (CEA). Staff at the Oak Ridge National Laboratory (ORNL) in the US and the Centre de Valduc in France planned this experiment. The experiment was conducted on October 19, 2010 in the SILENE critical assembly facility at Valduc. Several other organizations contributed to this experiment and the subsequent evaluation, including CEA Saclay, Lawrence Livermore National Laboratory (LLNL), the Y-12 National Security Complex (NSC), Babcock International Group in the United Kingdom, and Los Alamos National Laboratory (LANL). The goal of this experiment was to measure neutron activation and thermoluminescent dosimeter (TLD) doses from a source similar to a fissile solution critical excursion. The resulting benchmark can be used for validation of computer codes and nuclear data libraries as required when performing analysis of criticality accident alarm systems (CAASs). A secondary goal of this experiment was to qualitatively test performance of two CAAS detectors similar to those currently and formerly in use in some US DOE facilities. The detectors tested were the CIDAS MkX and the Rocky Flats NCD-91. The CIDAS detects gammas with a Geiger-Muller tube and the Rocky Flats detects neutrons via charged particles produced in a thin 6 LiF disc depositing energy in a Si solid state detector. These detectors were being evaluated to determine whether they would alarm, so they were not expected to generate benchmark quality data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Proposed Methodology for Evaluating and Validating TSLs [Slides]

This presentation begins by providing an overview of the research and discusses recent efforts in validating thermal neutron scattering cross sections, including differential cross section measurements at ORNL for evaluation and validation, total cross section measurements at RPI, pulsed-neutron die-away experiments at LLNL, and integral criticality experiments by LLNL. The presentation also proposes a methodology not only for validating thermal scattering files that utilizes all available experimental data, but also for evaluating new libraries as demonstrated on polystyrene. In conclusion, polystyrene evaluation was conducted using multiple experiments, including differential and integral. The proposed methodology has been shown to improve neutron transport and files have been submitted to NNDC for inclusion in ENDF/B-VIII.1 release. MCT-012 & PCM-002 has been relatively insensitive to changes in $\mathcal{S}(α,β)$. The research found that differences in differential results don’t always propagate to differences in integral results, hence why evaluation of differential data important. Future work on the project is also discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Spectral-average cross section validation in LR-0 reactor spectrum of {sup 55}Mn(n,2n), {sup 90}Zr(n,2n) and {sup 127}I(n,2n) reactions - 25362

This article deals with the validation of spectral average cross-sections (SACS) of {sup 55}Mn(n,2n){sup 54}Mn, {sup 90}Zr(n,2n){sup 89}Zr and {sup 127}I(n,2n){sup 126}I reactions in well-defined LR-0 reactor spectrum. The measurement of SACS for selected reactions is of high interest because they are used for the practical reactor dosimetry and also for refinement of prompt fission neutron spectra of {sup 235}U in the region of higher energies. Various experiments for description of neutron field in reactor and detector characterization, which are necessary for validation, are described. The spectral average cross-sections are derived from Net Peak Areas of irradiated samples measured using a semiconductor high purity germanium detector. The spectral average cross section in {sup 235}U prompt fission neutron spectrum was experimentally determined to be 0.239 ± 0.015 mb for {sup 55}Mn, 1.209 ± 0.052 mb for {sup 127}I and 0.107 ± 0.005 mb for {sup 90}Zr. The obtained results were compared with MCNP6 calculations using ENDF/B-VII.0, ENDF/B-VII.1, JEFF-3.1, JEFF-3.2, JENDL-3.3, JENDL-4, ROSFOND-2010, CENDL-3.1 and IRDFF-1.05 nuclear data libraries. Notable discrepancies were found in {sup 90}Zr(n,2n){sup 89}Zr and {sup 127}I(n,2n){sup 126}I reactions. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The veto system of the DarkSide-50 experiment

Nuclear recoil events produced by neutron scatters form one of the most important classes of background in WIMP direct detection experiments, as they may produce nuclear recoils that look exactly like WIMP interactions. In DarkSide-50, we both actively suppress and measure the rate of neutron-induced background events using our neutron veto, composed of a boron-loaded liquid scintillator detector within a water Cherenkov detector. This paper is devoted to the description of the neutron veto system of DarkSide-50, including the detector structure, the fundamentals of event reconstruction and data analysis, and basic performance parameters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Expansion of the Fast Neutron Hodoscope at TREAT to Support Fuel Safety Experiments

In 2024 the Fuel Motion Monitoring System (FMMS), or Hodoscope, at the Transient Reactor Test Facility, is being expanded from 96 viewing channels to 192 viewing channels, effectively doubling the FMMS field of view. Here, this increase in capability will allow the FMMS to support larger scale fuel tests, encompassing height-of-core test devices, test devices with multi-pin fuel assemblies, and test devices with recirculating coolant flow. Work supporting the expansion included refurbishing 96 additional proton recoil scintillator (PRS) detectors, doubling the data acquisition system (DAS) installed architecture, improving time synchronization in the DAS, and new research to measure the PRS detector energy-dependent, fast-neutron detection efficiency. In addition, laboratory activities have produced an improved benchtop testing capability for assessing the DAS, time synchronization, and external start triggering, along with an updated capability to scan PRS detectors to develop a preliminary flat-field normalization prior to deployment to TREAT.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

A Measurement of the Ionization Efficiency of Nuclear Recoils in Silicon

We have measured the ionization efficiency of silicon nuclear recoils with kinetic energy between 1.8 and 20 keV . We bombarded a silicon-drift diode with a neutron beam to perform an elastic-scattering experiment. A broad-energy neutron spectrum was used and the nuclear recoil energy was reconstructed using a measurement of the time of flight and scattering angle of the scattered neutron. The overall trend of the results of this work is well described by the theory of Lindhard et al. above 4 keV of recoil energy. Below this energy, the presented data shows a deviation from the model. The data indicates a faster drop than the theory prediction at low energies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Distribution of Neutrons in a Cold Lucite Moderator

A series of experiments was performed in 2010 to study the behavior of neutrons in a cold Lucite moderator. The diffusion of neutrons in a cold moderator is described as a two-step process. In the first step, the fast neutrons produced by a neutron source collide with the nuclei of Lucite, losing energy until they reach thermal energies. In the second step, the thermal neutrons continue to diffuse without any significant loss of energy until they are absorbed or leak out of the system. However, because the Lucite moderator is at low temperature, there is less up scattering in the neutron energy compared to a Lucite moderator at room temperature. Experiments were performed to study the behavior of neutrons and their distribution in a cold Lucite moderator and their results compared to simulations. Based on these measurements, an estimation of the absorption cross section at -78.5 °C yielded a value of 0.54 barns ± 0.02 barns.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Godiva IV Thermal Neutron Dosimetry Modeling and Variance Reduction

The transfer of the Godiva IV experiment from the Los Alamos Critical Experiments Facility (LACEF) to the National Critical Experiments Research Center (NCERC) introduced a vastly different experiment room return to the neutron flux. The contribution of the background to the burst neutron energy spectrum is significant in the thermal and epithermal neutron energies. Target materials may be placed in various locations in the Godiva room, or outside of the room, for thermal neutron activation. Modeling of this dosimetry problem in Monte Carlo N-Particle (MCNP) presented a novel challenge compared to previous Godiva IV glory hole irradiation simulations. An advanced dosimetry modeling framework for high efficiency calculations in locations far from the Godiva IV fission source was desired. The mesh-based weight windows and point detector advanced variance reduction techniques in MCNP were implemented and tested using adaptations of the critical experiment benchmark model of the Godiva IV problem. The models were validated against measured activations of Nickel, Indium, Scandium, and Cobalt foils at locations 2 meters from the Godiva IV core. Dosimetry measurements were performed in collaboration with Sandia National Laboratory. The weight windows and point detector variance reduction coupled method resulted in the highest problem efficiency.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evaluated Iridium, Yttrium, and Thulium Cross Sections and Integral Validation Against Critical Assembly and Bethe Sphere Measurements

We describe new dosimetry (radiochemical) ENDF evaluations for yttrium, iridium, and thulium. These LANL2006 evaluations were based upon measured data and on nuclear model cross section calculations. In the case of iridium and yttrium, new measurements using the GEANIE gamma-ray detector at LANSCE were used to infer (n,xn) cross sections, the measurements being augmented by nuclear model calculations using the GNASH code. The thulium isotope evaluations were based on GNASH calculations and older measurements. The evaluated cross section data are tested through comparisons of simulations with measurements of reaction rates in critical assemblies and in Bethe sphere (sometimes called Wyman sphere) integral experiments. Two types of Bethe sphere experiments were studied - a LiD experiment that had a significant component of 14 MeV neutrons, and a LiD-U experiment that additionally had varying amounts of fission neutrons depending upon the location. These simulations were performed with the MCNP code using continuous energy Monte Carlo, and because the neutron fluences can be modeled fairly accurately by MCNP at different locations in these assemblies, the comparisons provide a valuable validation test of the accuracy of the evaluated cross sections and their energy dependencies. The MCNP integral reaction rate validation testing for the three detectors yttrium, iridium, and thulium, in the LANL2006 database is summarized as follows: (1) (n,2n)near 14 MeV: In 14 MeV-dominated locations (the LiD Bethe spheres and the outer regions of the LiD-U Bethe spheres), the (n,2n) products are modeled very well for all three detectors, suggesting that the evaluated {sup 89}Y(n,2n), {sup 191}Ir(n,2n), and {sup 169}Tm(n,2n) cross sections are accurate to better than about 5% near 14 MeV; (2) (n,2n)near threshold: In locations that have a significant number of fission spectrum neutrons or downscattered neutrons from 14 MeV inelastic scattering (the central regions of the LiD-U spheres and the fast critical assemblies), the (n,2n) products are overpredicted by 5-30 % for the three detectors, suggesting either the threshold region (n,2n) cross sections are too high, or that the MCNP-simulated neutron flux is too large for neutron energies above about 8 MeV; (3) Capture: The capture products for yttrium are modeled accurately for the LiD Bethe spheres, but are underpredicted by about 20% for the LiD-U Bethe spheres and the critical assemblies; for iridium-191 they are predicted accurately in the critical assemblies; and for thulium they are generally overpredicted by 10-30 %; (4) Inelastic scattering in iridium: The evaluated {sup 193}Ir(n,n{sup '}){sup 193m}Ir cross section performs well over a very wide range of neutron spectra (where the 193m/190 spectrum hardness index varies by over three orders of magnitude), the differences between simulation and experiment typically being better than 10-15%; (5) Iridium 193m/190 spectrum hardness index: Our simulations reproduce the measured 193m/190 data typically to better than 10-20% over three orders of magnitude in the 193m/190 ratio. The aforementioned indications from data testing involving assemblies containing actinides - that the (n,2n) products are overpredicted by 5-30% - could be used to motivate a decrease in the evaluated (n,2n) cross sections in the approximately 8-12 MeV range. However, at this stage we have not modified these cross sections since: (a) They are consistent with the cross section laboratory measurements; and (b) It is possible that the cross sections are correct and instead the simulated integral assembly neutron spectrum is too high for neutron energies above 8 MeV. The latter possibility is particularly intriguing given all three detector materials showed a bias in the same direction, and that the evaluated actinide prompt fission spectra and inelastic scattering data are probably uncertain to at least 20% above 8 MeV. We also discuss refinements needed in the transport methods to faithfully represent the evaluated data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

In Situ TEM Multi-Beam Ion Irradiation as a Technique for Elucidating Synergistic Radiation Effects

Materials designed for nuclear reactors undergo microstructural changes resulting from a combination of several environmental factors, including neutron irradiation damage, gas accumulation and elevated temperatures. Typical ion beam irradiation experiments designed for simulating a neutron irradiation environment involve irradiating the sample with a single ion beam and subsequent characterization of the resulting microstructure, often by transmission electron microscopy (TEM). This method does not allow for examination of microstructural effects due to simultaneous gas accumulation and displacement cascade damage, which occurs in a reactor. Sandia’s in situ ion irradiation TEM (I3TEM) offers the unique ability to observe microstructural changes due to irradiation damage caused by concurrent multi-beam ion irradiation in real time. This allows for time-dependent microstructure analysis. A plethora of additional in situ stages can be coupled with these experiments, e.g., for more accurately simulating defect kinetics at elevated reactor temperatures. This work outlines experiments showing synergistic effects in Au using in situ ion irradiation with various combinations of helium, deuterium and Au ions, as well as some initial work on materials utilized in tritium-producing burnable absorber rods (TPBARs): zirconium alloys and LiAlO2.

Taylor, Caitlin↗

Assessing the impact of uniform rotation on the structure of neutron stars

Driven by recent laboratory experiments and astronomical observations, significant advances have deepened our understanding of neutron-star physics. NICER's Pulse Profile Modeling has refined our knowledge of neutron star masses and radii, while gravitational-wave detections have revealed key insights into the structure of neutron stars. Particularly relevant is the extraction of the tidal deformability by the LIGO-Virgo collaboration and the most recent determination of stellar radii by NICER, both suggesting a relatively soft equation of state (EOS) at intermediate densities. Additionally, measurements from the PREX collaboration and from pulsar timing suggest instead that the EOS is stiff in the vicinity of saturation density and at the highest densities accessible to date. But how stiff can the EOS be at these very high densities? Recent events featuring compact objects near the “lower mass gap” have raised questions about the existence of very massive neutron stars. Motivated by this finding and in light of new refinements to theoretical models, we explore the possibility that these massive objects may indeed be rapidly rotating neutron stars. Here, we explore how rotation affects both the maximum neutron star mass and their associated radii, and discuss the implications they may have on the equation of state.

Equations of state of nuclear matter↗

Higher velocity, high-foot implosions on the National Ignition Facility laser

By increasing the velocity in “high foot” implosions [Dittrich et al., Phys. Rev. Lett. 112, 055002 (2014); Park et al., Phys. Rev. Lett. 112, 055001 (2014); Hurricane et al., Nature 506, 343 (2014); Hurricane et al., Phys. Plasmas 21, 056314 (2014)] on the National Ignition Facility laser, we have nearly doubled the neutron yield and the hotspot pressure as compared to the implosions reported upon last year. The implosion velocity has been increased using a combination of the laser (higher power and energy), the hohlraum (depleted uranium wall material with higher opacity and lower specific heat than gold hohlraums), and the capsule (thinner capsules with less mass). We find that the neutron yield from these experiments scales systematically with a velocity-like parameter of the square root of the laser energy divided by the ablator mass. By connecting this parameter with the inferred implosion velocity (v), we find that for shots with primary yield >1 × 10{sup 15} neutrons, the total yield ∼ v{sup 9.4}. This increase is considerably faster than the expected dependence for implosions without alpha heating (∼v{sup 5.9}) and is additional evidence that these experiments have significant alpha heating.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Irradiation Testing of a SiC/SiC Channel Box in the High Flux Isotope Reactor

This report provides a summary of the experiment design and the neutronics and structural analyses of a miniature SiC/SiC channel box that will be irradiated in the High Flux Isotope Reactor (HFIR). The goal of this experiment is to evaluate the lateral bowing in the channel box during irradiation under a radial neutron flux gradient. The concern is that lateral bowing could potentially block coolant flow or interfere with control blade movements in boiling water reactors (BWRs). The experiments described in this work will help validate thermomechanical models of channel box bowing. The experiment design allows for one channel box specimen to be irradiated in the HFIR while being directly cooled by the reactor coolant. Monte Carlo neutronics analyses are performed to determine the three-dimensional profile of the dose rate in the channel box. Dose is then converted to volumetric swelling, using literature data, and the resulting swelling profile is used as an input to structural finite element calculations that predict lateral bowing.

36 MATERIALS SCIENCE↗

Nanoscale Disorder and Local Electronic Properties of CaCu,Ti,012: An Integrated Study of Electron, Neutron and X-ray Diffraction, X-ray Absorption Fine Structure and First Principles Calculations

We report a combined experimental and theoretical study of CaCu{sub 3}Ti{sub 4}O{sub 12}. Based on our experimental observations of nanoscale regions of Ca-Cu antisite defects in part of the structure, we carried out density-functional theory (DFT) calculations that suggest a possible electronic mechanism to explain the gigantic dielectric response in this material. The defects are evident in atomically resolved transmission electron microscopy measurements, with supporting evidence from a quantitative analysis of the electron diffraction and DFT which suggests that such defects are reasonable on energetic grounds. To establish the extent of the defects, bulk average measurements of the local structure were carried out: extended x-ray absorption fine structure (EXAFS), atomic pair-distribution function analysis of neutron powder-diffraction data, and single-crystal x-ray crystallography. The EXAFS data are consistent with the presence of the nanoclustered defects with an estimate of less than 10% of the sample being disordered while the neutron powder-diffraction experiments place an upper of -5% on the proportion of the sample in the defective state. Because of the difficulty of quantifying nanoscale defects at such low levels, further work will be required to establish that this mechanism is operative in CaCu{sub 3}Ti{sub 4}O{sub 12} but it presents a nontraditional plausible avenue for understanding colossal dielectric behavior.

36 MATERIALS SCIENCE↗