Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reference”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Impedance studies of Ni/Cd and Ni/H cells using the cell case as reference electrode

Many impedance studies were carried out on Ni electrodes and Ni/Cd and Ni/H batteries. In order for impedance to become a diagnostic tool, accurate and reproducible measurements must be made, and some way of separating the contributions of the individual electrodes must be found. Using the PAR and the Solartron impedance equipment, studies have found that consistent measurements can be made if the cells or electrodes are equilibrated at the voltage of interest. In the charged state, equilibration times required are short, on the order of a few hours or less, but the equilibration time required becomes progessively longer as the voltage is lowered. The cell case can be used as a reference electrode during impedance measurements. The voltage of the case with respect to the electrodes is unimportant provided that it does not change appreciably during the course of the measurement. Measurements were made with several uncycled Ni/Cd cells, one from a lot which was known to have faulty Cd electrodes and another from a lot which showed excellent cycle life and presumably had good Cd electrodes. The impedances of the Ni electrodes vs. the case were similar, while the impedance of the poor Cd electrodes vs. the case. A 50 AH Ni/H cell was also investigated. After subtraction of the ohmic resistances, the sums of the impedances of the individual electrodes were very close to the impedance of the total cell. This indicates that the method is valid for examining the characteristics of the individual electrodes in situ.

Reid, Margaret A.↗

Holographic interferometry with an injection seeded Nd:YAG laser and two reference beams

The performance of twin injection seeded Nd:YAG lasers is compared with the performance of an argon-ion laser for recording dual-reference-beam holograms in AGFA 8E56 emulsion. Optical heterodyning is used to measure interference, and the results are expressed in terms of heterodyning signal level and intensity signal-to-noise. The Nd:YAG laser system is to be used for optical inspections of structures for cracks, defects, gas leaks, and structural changes.

Decker, Arthur J.↗

The celestial reference frame defined by VLBI

VLBI currently produces the most accurate positions of celestial objects. From 1979 to 1987, 114 extragalactic radio sources have been observed with dual-frequency Mark III VLBI as part of the NASA Crustal Dynamics Project and the NGS POLARIS/IRIS program. The formal statistical errors of conventional celestial coordinates are as small as 0.3 milliarcseconds. The fundamental quantity measured by VLBI is the arc length between radio sources. Thus, it is suggested that VLBI be used to establish a coordinate reference frame based solely on radio positions, and that this system not necessarily be coupled to right ascension and declination.

Ma, C.↗

Radio reference frame stability from VLBI data

Intercontinental radio interferometric measurements between NASA's Deep Space Network stations yield a catalog of positions of 106 extragalactic radio sources, uniformly distributed between -45 and +85 deg declination. Almost all of the source positions have formal uncertainties between 0.5 and 3 milliarcseconds. Estimates of three independent sets of 32 source coordinates at average epochs 1980.0, 1983.2, and 1984.5 assess the level of stability of the reference frame over a five-year period. Comparisons of the three sets of source coordinates show a number of cases of greater than 2 sigma differences, particularly between the 1984-85 and 1981-83 periods. No sources, however, show 2 sigma shifts among both pairs of epochs. Upper limits of the order of 1 mas/yr can be placed on the time rates of change of the 32 source coordinates.

Sovers, O. J.↗

Model reference, sliding mode adaptive control for flexible structures

A decentralized model reference adaptive approach using a variable-structure sliding model control has been developed for the vibration suppression of large flexible structures. Local models are derived based upon the desired damping and response time in a model-following scheme, and variable structure controllers are then designed which employ colocated angular rate and position feedback. Numerical simulations have been performed using NASA's flexible grid experimental apparatus.

Yurkovich, S.↗

Outputs of paired Gabor filters summed across the background frame of reference predict the direction of movement

A cortical neural network that computes the visibility of shifts in the direction of movement is proposed. The network computes: (1) the magnitude of the position difference between the test and background patterns, (2) localized contrast differences at different spatial scales analyzed by computing temporal gradients of the difference and sum of the outputs of paired even- and odd-symmetric bandpass filters convolved with the input pattern, and (3) using global processes that pool the output from paired even- and odd-symmetric simple and complex cells across the spatial extent of the background frame of reference the direction a test pattern moved relative to a textured background. Evidence that magnocellular pathways are used to discriminate the direction of movement is presented. Since magnocellular pathways are used to discriminate the direction of movement, this task is not affected by small pattern changes such as jitter, short presentations, blurring, and different background contrasts that result when the veiling illumination in a scene changes.

Lawton, Teri B.↗

Calculation of the surface tension of liquid metals using a one-component-plasma reference system

The one-component-plasma (OCP) model is used as a reference system instead of the traditional hard-sphere fluid to calculate the liquid-vapor interfacial surface tension of liquid metals within the density functional formalism. The calculated surface tensions of the alkali metals are in excellent agreement with experiment. For the polyvalent metal Al, the result obtained is larger than experimental measurements. It is concluded that the OCP system is not suitable to describe the liquid-vapor phase transition in simple metals which have a nominal plasma parameter larger than the usual freezing value of about 178. The calculated interfacial widths in all cases are narrower than the expected experimental values.

Zeng, X. C.↗

Simple method for model reference adaptive control

A simple method is presented for combined signal synthesis and parameter adaptation within the framework of model reference adaptive control theory. The results are obtained using a simple derivation based on an improved Liapunov function.

Seraji, H.↗

Turbulence modeling in noninertial frames of reference

The effect of an arbitrary change of frame on the structure of turbulence models is examined from a fundamental theoretical standpoint. It is proven, as a rigorous consequence of the Navier-Stokes equations, that turbulence models must be form invariant under arbitrary translational accelerations of the reference frame and should only be affected by rotations through the intrinsic mean vorticity. A direct application of the invariance property along with the Taylor-Proudman Theorem, material frame-indifference in the limit of two-dimensional turbulence and Rapid Distortion Theory is shown to yield powerful constraints on the allowable form of turbulence models. Most of the commonly used turbulence models are demonstrated to be in serious violation of these constraints and consequently are inconsistent with the Navier-Stokes equations in non-inertial frames. Alternative models with improved non-inertial properties are developed and some simple applications to rotating turbulent flows are considered.

Speziale, Charles G.↗

Autonomous fault-tolerant attitude reference system using DTGs in symmetrically skewed configuration

A novel symmetrically skewed configuration for an attitude reference system (ARS) using three dynamically tuned gyros (DTGs) is developed. Simple schemes for autonomous detection and identification of a faulty DTG in real time and subsequent reconfiguration of the attitude estimation algorithm are proposed. The performance of the present configuration is shown to be better than that of configurations proposed earlier, and it is shown to have better features. It tolerates all types of failures of DTG failures, requires very simple computations, and gives less error in attitude estimate than the other configurations.

Murugesan, S.↗

Method For Model-Reference Adaptive Control

Relatively simple method of model-reference adaptive control (MRAC) developed from two prior classes of MRAC techniques: signal-synthesis method and parameter-adaption method. Incorporated into unified theory, which yields more general adaptation scheme.

Seraji, Homayoun↗

NASA/NBS (National Aeronautics and Space Administration/National Bureau of Standards) standard reference model for telerobot control system architecture (NASREM)

The document describes the NASA Standard Reference Model (NASREM) Architecture for the Space Station Telerobot Control System. It defines the functional requirements and high level specifications of the control system for the NASA space Station document for the functional specification, and a guideline for the development of the control system architecture, of the 10C Flight Telerobot Servicer. The NASREM telerobot control system architecture defines a set of standard modules and interfaces which facilitates software design, development, validation, and test, and make possible the integration of telerobotics software from a wide variety of sources. Standard interfaces also provide the software hooks necessary to incrementally upgrade future Flight Telerobot Systems as new capabilities develop in computer science, robotics, and autonomous system control.

Albus, James S.↗

A diagnostic for determining the quality of single-reference electron correlation methods

It was recently proposed that the Euclidian norm of the t sub 1 vector of the coupled cluster wave function (normalized by the number of electrons included in the correlation procedure) could be used to determine whether a single-reference-based electron correlation procedure is appropriate. This diagnostic, T sub 1, is defined for use with self consistent field molecular orbitals and is invariant to the same orbital rotations as the coupled cluster energy. T sub 1 is investigated for several different chemical systems which exhibit a range of multireference behavior, and is shown to be an excellent measure of the importance of nondynamical electron correlation and is far superior to C sub 0 from a singles and doubles configuration interaction wave function. It is further suggested that when the aim is to recover a large fraction of the dynamical electron correlation energy, a large T sub 1 (i.e., greater than 0.02) probably indicates the need for a multireference electron correlation procedure.

Lee, Timothy J.↗

A diagnostic for determining the quality of single-reference electron correlation methods

It was recently proposed that the Euclidian norm of the t(sub 1) vector of the coupled cluster wave function (normalized by the number of electrons included in the correlation procedure) could be used to determine whether a single-reference-based electron correlation procedure is appopriate. This diagnostic, T(sub 1) is defined for use with self-consistent-field molecular orbitals and is invariant to the same orbital rotations as the coupled cluster energy. T(sub 1) is investigated for several different chemical systems which exhibit a range of multireference behavior, and is shown to be an excellent measure of the importance of non-dynamical electron correlation and is far superior to C(sub 0) from a singles and doubles configuration interaction wave function. It is further suggested that when the aim is to recover a large fraction of the dynamical electron correlation energy, a large T(sub 1) (i.e., greater than 0.02) probably indicates the need for a multireference electron correlation procedure.

Lee, Timothy J.↗

Impedance studies of Ni/Cd and Ni/H2 cells using the cell case as a reference electrode

Impedance measurements have been made on several Ni/Cd and Ni/H2 flightweight cells using the case as a reference electrode. For these measurements the voltage of the case with respect to the anode or cathode is unimportant provided that it remains stable during the measurement of the impedance. In the cells measured so far, the voltages of the cell cases with respect to the individual electrodes differ from cell to cell even at the same overall cell voltage, but they remains stable with time. The measurements can thus be used to separate the cell impedance into the contributions of each electrode, allowing improved diagnosis of cell problems.

Reid, Margaret A.↗

VAPEPS user's reference manual, version 5.0

This is the reference manual for the VibroAcoustic Payload Environment Prediction System (VAPEPS). The system consists of a computer program and a vibroacoustic database. The purpose of the system is to collect measurements of vibroacoustic data taken from flight events and ground tests, and to retrieve this data and provide a means of using the data to predict future payload environments. This manual describes the operating language of the program. Topics covered include database commands, Statistical Energy Analysis (SEA) prediction commands, stress prediction command, and general computational commands.

Park, D. M.↗

PROTEUS two-dimensional Navier-Stokes computer code, version 1.0. Volume 3: Programmer's reference

A new computer code was developed to solve the 2-D or axisymmetric, Reynolds-averaged, unsteady compressible Navier-Stokes equations in strong conservation law form. The thin-layer or Euler equations may also be solved. Turbulence is modeled using an algebraic eddy viscosity model. The objective was to develop a code for aerospace applications that is easy to use and easy to modify. Code readability, modularity, and documentation were emphasized. The equations are written in nonorthogonal body-fitted coordinates, and solved by marching in time using a fully-coupled alternating-direction-implicit procedure with generalized first- or second-order time differencing. All terms are linearized using second-order Taylor series. The boundary conditions are treated implicitly, and may be steady, unsteady, or spatially periodic. Simple Cartesian or polar grids may be generated internally by the program. More complex geometries require an externally generated computational coordinate system. The documentation is divided into three volumes. Volume 3 is the Programmer's Reference, and describes the program structure, the FORTRAN variables stored in common blocks, and the details of each subprogram.

Towne, Charles E.↗

GPS inferred geocentric reference frame for satellite positioning and navigation

Accurate geocentric three-dimensional positioning is of great importance for various geodetic and oceanographic applications. While relative positioning accuracy of a few centimeters has become a reality using Very Long Baseline Interferometry (VLBI), the uncertainty in the offset of the adopted coordinate system origin from the geocenter is still believed to be of the order of one meter. Satellite Laser Ranging (SLR) is capable of determining this offset to better than 10 cm, though, because of the limited number of satellites, this requires a long arc of data. The Global Positioning System (GPS) measurements provide a powerful alternative for an accurate determination of this origin offset in relatively short period of time. Two strategies are discussed, the first utilizes the precise relative positions predetermined by VLBI, whereas the second establishes a reference frame by holding only one of the tracking sites longitude fixed. Covariance analysis studies indicate that geocentric positioning to an accuracy of a few centimeters can be achieved with just one day of precise GPS pseudorange and carrier phase data.

Malla, Rajendra P.↗