Search NASA⌕ Search

SEARCH · Search NASA

Results for “array detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Design and Technical Study of Neutrino Detector Spacecraft

A neutrino detector is proposed to be developed for use on a space probe in close orbit of the Sun. The detector will also be protected from radiation by a tungsten shield Sun shade, active veto array and passive cosmic shielding. With the intensity of solar neutrinos substantially greater in a close solar orbit than on the Earth only a small 250 kg detector is needed. It is expected that this detector and space probe studying the core of the Sun, its nuclear furnace and particle physics basic properties will bring new knowledge beyond what is currently possible for Earth bound solar neutrino detectors.

Design and Technical Study↗

Self-Referencing Hartmann Test for Large-Aperture Telescopes

A method is proposed for end-to-end, full aperture testing of large-aperture telescopes using an innovative variation of a Hartmann mask. This technique is practical for telescopes with primary mirrors tens of meters in diameter and of any design. Furthermore, it is applicable to the entire optical band (near IR, visible, ultraviolet), relatively insensitive to environmental perturbations, and is suitable for ambient laboratory as well as thermal-vacuum environments. The only restriction is that the telescope optical axis must be parallel to the local gravity vector during testing. The standard Hartmann test utilizes an array of pencil beams that are cut out of a well-corrected wavefront using a mask. The pencil beam array is expanded to fill the full aperture of the telescope. The detector plane of the telescope is translated back and forth along the optical axis in the vicinity of the nominal focal plane, and the centroid of each pencil beam image is recorded. Standard analytical techniques are then used to reconstruct the telescope wavefront from the centroid data. The expansion of the array of pencil beams is usually accomplished by double passing the beams through the telescope under test. However, this requires a well-corrected, autocollimation flat, the diameter or which is approximately equal to that of the telescope aperture. Thus, the standard Hartmann method does not scale well because of the difficulty and expense of building and mounting a well-corrected, large aperture flat. The innovation in the testing method proposed here is to replace the large aperture, well-corrected, monolithic autocollimation flat with an array of small-aperture mirrors. In addition to eliminating the need for a large optic, the surface figure requirement for the small mirrors is relaxed compared to that required of the large autocollimation flat. The key point that allows this method to work is that the small mirrors need to operate as a monolithic flat only with regard to tip/tilt and not piston because in collimated space piston has no effect on the image centroids. The problem of aligning the small mirrors in tip/tilt requires a two-part solution. First, each mirror is suspended from a two-axis gimbal. The orientation of the gimbal is maintained by gravity. Second, the mirror is aligned such that the mirror normal is parallel to gravity vector. This is accomplished interferometrically in a test fixture. Of course, the test fixture itself needs to be calibrated with respect to gravity.

Korechoff, Robert P.↗

Shortwave infrared 512 x 2 line sensor for earth resources applications

As part of the NASA remote-sensing Multispectral Linear Array Program, an edge-buttable 512 x 2 IRCCD line image sensor with 30-micron Pd2Si Schottky-barrier detectors is developed for operation with passive cooling at 120 K in the 1.1-2.5 micron short infrared band. On-chip CCD multiplexers provide one video output for each 512 detector band. The monolithic silicon line imager performance at a 4-ms optical integration time includes a signal-to-noise ratio of 241 for irradiance of 7.2 microwatts/sq cm at 1.65 microns wavelength, a 5000 dynamic range, a modulation transfer function, greater than 60 percent at the Nyquist frequency, and an 18-milliwatt imager chip total power dissipation. Blemish-free images with three percent nonuniformity under illumination and nonlinearity of 1.25 percent are obtained. A five SWIR imager hybrid focal plane was constructed, demonstrating the feasibility of arrays with only a two-detector loss at each joint.

Tower, J. R.↗

Self-scanned Digicon - A digital image tube for astronomical spectroscopy

We have successfully fabricated, tested, and operated a digital image tube consisting of a magnetically focused image intensifier tube in which a self-scanned linear array of 1024 silicon photodiodes operating in the EBS mode serves as the photoelectron image detector, amplifier, and intermediate image storage device. Integral on-chip MOS shift registers driven by an external clock sequentially interrogate the photodiodes through MOS FET multiplex switch arrays. Each output frame is a sequence of 256 analog pulses on each of four video lines. Laboratory and observing tests show that the output signal is photoelectron shot noise limited over at least a range of 1-100,000 detected photoelectrons per picture element, indicating that single photon detection is achieved. High-resolution astronomical spectroscopy has been carried out in the coude spectrograph of the 2.7-m telescope at McDonald Observatory. Examples are shown.

Tull, R. G.↗

Time delay and integration detectors using charge transfer devices

An imaging system comprises a multi-channel matrix array of CCD devices wherein a number of sensor cells (pixels) in each channel are subdivided and operated in discrete intercoupled groups of subarrays with a readout CCD shift register terminating each end of the channels. Clock voltages, applied to the subarrays, selectively cause charge signal flow in each subarray in either direction independent of the other subarrays. By selective application of four phase clock voltages, either one, two or all three of the sections subarray sections cause charge signal flow in one direction, while the remainder cause charge signal flow in the opposite direction. This creates a form of selective electronic exposure control which provides an effective variable time delay and integration of three, six or nine sensor cells or integration stages. The device is constructed on a semiconductor sustrate with a buried channel and is adapted for front surface imaging through transparent doped tin oxide gates.

Mccann, D. H.↗

Enhancement of High-Speed Infrared Array Electronics (Center Director's Discretionary Fund)

A state-of-the-art infrared detector was to be used as the sensor in a new spectrometer-camera for astronomical observations. The sensitivity of the detector required the use of low-noise, high-speed electronics in the system design. The key component in the electronic system was the pre-amplifier that amplified the low voltage signal coming from the detector. The system was designed based on the selection of the amplifier and that was driven by the maximum noise level, which would yield the desired sensitivity for the telescope system.

Sutherland, W. T.↗

Development of large CCD arrays with enhanced UV performance

A development status evaluation is presented for proprietary UV-range CCDs for military and scientific applications requiring pixel sizes in the 18-micron range. The most recent developments in UV/X-ray responsive detectors have their bases in the backside illumination of multipinned phase (MPP) 1024 x 1024 CCD arrays, as well as in the initial exploration of open-pinned phase (OPP) techniques. The frontside performance of both MPP and OPP devices is noted to be excellent as well, and pinouts and mounting techniques have been defined which allow easy front-back operation comparisons. Novel backside processing techniques are being refined.

Varian, Richard H.↗

A large imaging array CCD program

Test results on charge coupled device (CCD) imaging arrays (100 x 160 pixel and 400 x 400 pixel) employed as imaging detectors are reported, along with expected low light level (LLL) performance. Reasons for selection of a thinned backside-illuminated buried-channel three-phase CCD variant are indicated. The LLL performance and long storage time capability of the CCD imaging array recommend it for stellar photometry, detection and tracking of faint objects, and other astronomical applications.

Vescelus, F. E.↗

The infrared spectrograph during the SIRTF pre-definition phase

A test facility was set up to evaluate back-illuminated impurity band detectors constructed for an infrared spectrograph to be used on the Space Infrared Telescope Facility (SIRTF). Equipment built to perform the tests on these arrays is described. Initial tests have been geared toward determining dark current and read noise for the array. Four prior progress reports are incorporated into this report. They describe the first efforts in the detector development and testing effort; testing details and a new spectrograph concept; a discussion of resolution issues raised by the new design; management activities; a review of computer software and testing facility hardware; and a review of the preamplifier constructed as well as a revised schematic of the detector evaluation facility.

Houck, James R.↗

A New Large-Well 1024x1024 Si:As Detector for the Mid-Infrared

We present a description of a new 1024x1024 Si:As array designed for ground-based use from 5 - 28 microns. With a maximum well depth of 5e6 electrons, this device brings large-format array technology to bear on ground-based mid-infrared programs, allowing entry to the mega-pixel realm previously only accessible to the near-IR. The multiplexer design features switchable gain, a 256x256 windowing mode for extremely bright sources, and it is two-edge buttable. The device is currently in its final design phase at DRS in Cypress, CA. We anticipate completion of the foundry run in October 2005. This new array will enable wide field, high angular resolution ground-based follow up of targets found by space-based missions such as the Spitzer Space Telescope and the Wide-field Infrared Survey Explorer (WISE).

astronomy↗

InSb arrays with CCD readout for 1.0- to 5.5-microns infrared applications

There were two approaches for fabricating indium antimonide (InSb) arrays with CCD readout discussed. The hybrid approach integrated InSb detectors and silicon CCDs in a modular assembly via an advanced interconnection technology. In the monolithic approach, the InSb infrared detectors and the CCD readout were integrated on the same InSb chip. Both approaches utilized intrinsic (band-to-band) photodetection with the attendant advantages over extrinsic detectors. The status of each of these detector readout concepts, with pertinent performance characteristics, was presented.

Phillips, J. D.↗

The UCSD/MIT hard X-ray and low energy gamma-ray experiment for HEAO-1 - Design and early results

Primary scientific objectives of the experiment are the measurement of the spectra and time variations of discrete sources and the spectrum and isotropy of the diffuse background, all in the 10 keV to 10 MeV energy range. The instrument consists of an array of 7 NaI(Tl)/CsI(Na) phoswich-type detectors and 8 large CsI(Na) shields. In order to achieve the maximum sensitivity allowed by weight, data rate and funding constraints of the mission, three detector and aperture geometries were selected. The instrument's total sensitive area is 494 sq cm. The fields of view vary from 1.7 deg x 20 deg FWHM at low energies to 43 deg FWHM at high energies. The basic instrument concepts, details of the mechanical and electrical design, and pre-launch calibrations are presented. In-orbit performance is described and background measurements are analyzed and used to estimate the experiment's ultimate sensitivity.

Matteson, J. L.↗

Some isotopic abundances in the cosmic radiation

Cosmic ray nuclei with Z not less than 10 have been observed in a detector which measures charge with a double scintillator-Cherenkov array and mass by combining the Cherenkov signal with residual range measured in nuclear emulsions. Results are presented for the isotopic analyses of Al, Ca, Sc, Mn, Fe, Co, Ni and Cu in the energy range 300-800 MeV/amu.

Young, J. S.↗

Self-heated thermocouples for far-infrared detection

A novel self-heated Bi-Sb thermocouple for far-infrared detection has been developed. The detector is suitable for integration with monolithic antennas and imaging arrays. The device is fabricated in a single photolithography masking step using a photoresist-bridge technique. This bridge technique has also been used to make microbolometers with lower 1/f noise than those made by two conventional masking steps. The thermocouples have a noise equivalent power of 7 x 10 to the -10th W/sq rt of Hz and a 3-dB frequency response of 150 kHz.

Neikirk, D. P.↗

Sensor failure and multivariable control for airbreathing propulsion systems

A new sensor/actuator failure analysis technique for turbofan jet engines was developed. Three phases of failure analysis, namely detection, isolation, and accommodation are considered. Failure detection and isolation techniques are developed by utilizing the concept of Generalized Likelihood Ratio (GLR) tests. These techniques are applicable to both time varying and time invariant systems. Three GLR detectors are developed for: (1) hard-over sensor failure; (2) hard-over actuator failure; and (3) brief disturbances in the actuators. The probability distribution of the GLR detectors and the detectability of sensor/actuator failures are established. Failure type is determined by the maximum of the GLR detectors. Failure accommodation is accomplished by extending the Multivariable Nyquest Array (MNA) control design techniques to nonsquare system designs. The performance and effectiveness of the failure analysis technique are studied by applying the technique to a turbofan jet engine, namely the Quiet Clean Short Haul Experimental Engine (QCSEE). Single and multiple sensor/actuator failures in the QCSEE are simulated and analyzed and the effects of model degradation are studied.

Behbehani, K.↗

Interactions of heavy nuclei, Kr, Xe and Ho, in light targets

Over the past few years, the HEAO-3 measurements of the abundances of ultra-heavy cosmic ray nuclei (Z 26) at earth have been analyzed. In order to interpret these abundances in terms of a source composition, allowance must be made for the propagation of the nuclei in the interstellar medium. Vital to any calculation of the propagation is a knowlege of the total and partial interaction cross sections for these heavy nuclei on hydrogen. Until recently, data on such reactions have been scarce. However, now that relativistic heavy ion beams are available at the LBL Bevalac, some of the cross sections of interest can be measured at energies close to those of the cosmic ray nuclei being observed. During a recent calibration at the Bevalac of an array similar to the HEAO-C3 UH-nuclei detector, targets of raphite (C), polyethylene (CH2), and aluminum were exposed to five heavy ion beams ranging in charge (Z) from 36 to 92. Total and partial charge changing cross sections for the various beam nuclei on hydrogen can be determined from the measured cross sections on C and CH2, and will be applied to the propagation problem. The cross sections on Al can be used to correct the abundances of UH cosmic rays observed in the HEAO C-3 detector for interactions in the detector itself.

Kertzman, M. P.↗

A Shuttle Imaging Spectrometer Experiment for the late 1980's

The Shuttle Imaging Spectrometer Experiment (SISEX), proposed as a next experimental step in the development of advanced earth remote sensing technology, is capable of imaging the earth's surface simultaneously in 128 spectral bands covering the range from 0.4 to 2.5 micrometers. Laboratory and field measurements have suggested the utility of high-spectral-resolution remote sensing, and an aircraft-borne precursor to the SISEX has demonstrated the ability to distinguish among differing vegetation and rock types - in certain cases making unique identifications. The SISEX instrument utilizes an area-array focal plane, populated by visual- and infrared-sensitive detectors, to acquire simultaneous spatial and spectral information on a line-by-line basis. The spectrum is dispersed by means of a prism spectrometer. The performance analysis indicates that the scientific requirements for radiometric precision can be achieved using optics with an effective circular aperture of 11 cm.

Wellman, J. B.↗

Wide-Angle, Flat-Field Telescope

All-reflective system unvignetted. Wide-angle telescope uses unobstructed reflecting elements to produce flat image. No refracting elements, no chromatic aberration, and telescope operates over spectral range from infrared to far ultraviolet. Telescope used with such image detectors as photographic firm, vidicons, and solid-state image arrays.

Hallam, K. L.↗