Comparison of Actuation Methods for Wake Control in Wind Plants
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Not provided.
Explore the source record for details and available documents.
Reliably mitigating disruptions is essential for ITER to meet its long-term operational research plan without damage to the in-vessel components. Currently, the shattered pellet injection (SPI) technique is the most effective radiator of thermal energy and has been chosen for the baseline disruption mitigation system (DMS) for ITER. The SPI process uses cryogenic temperatures to desublimate material into the barrel of a pipe gun forming a solid cylindrical pellet. Pellets for ITER will initially be hydrogen and hydrogen-neon mixtures. Once formed, pellets are dislodged and accelerated using high-pressure gas (40-60 bar) delivered by a fast-opening valve. The solenoid valves currently used for SPI experiments will not operate in an ITER environment due to the large background magnetic field. An ITER prototype fast-opening valve, called a flyer plate valve (FPV), has been designed and has undergone a wide range of testing. The FPV operates by pulsing current through a pancake coil that is closely coupled with a ``flyer plate.'' The flyer plate is an aluminum plate in which eddy currents are generated creating a repulsive force from the pancake coil. The force generated in the flyer plate rapidly lifts the valve tip off the seat and delivers a pulse of gas to the rear of the pellet, breaking it free from the barrel and accelerating the pellet downstream to its intended target. The design of the valve has been iterated on over the lifetime of this project, as the DMS for ITER shifted from massive gas injection (MGI) to SPI. The most recent design has been tested, and operational ranges have been mapped. The valve must survive 3000+ cycles in an ITER-like magnetic field. The principal functional requirement of this valve is to reliably dislodge and accelerate hydrogen (or H-Ne mixture) pellets into ITER. The valve was mated with an ITER SPI test stand and has been shown to be capable of launching pellets reliably. The valve and power supply design will be discussed in this article, along with the various testing setups used to determine the feasibility of this valve for use on ITER.
Explore the source record for details and available documents.
The use of surveillance specimens was identified in a roadmap (Sims, 2010, ASME HTGR Code Development Roadmap, STP-NU-045, American Society of Mechanical Engineers, New York, NY) developed for the U.S. Nuclear Regulatory Commission for non-light water reactors that are intended to have very long design lives on the order of 500,000 hours. Creep rupture, long term strain accumulation, creep-fatigue damage, and their interaction with environmental effects require significant extrapolation from shorter term tests. Surveillance specimens provide a means for confirmation of these extrapolations in-situ. The effects of cyclic service on creep-fatigue damage would be particularly challenging based on conventional mechanical testing. Proposed herein is a passive cyclic testing methodology that lends itself well to in-situ surveillance applications. The concept is based on utilizing the difference in the thermal expansion coefficient of candidate materials to generate cyclic loading based on operational thermal transients. Prototypical specimen designs are proposed and their in-situ response to representative plant operation are evaluated.
Abstract not provided.
The development of a polydimethylsiloxane (PDMS) microfluidic microbeads trapping device is reported in this paper. Besides fluid channels, the proposed device includes a pneumatic control chamber and a beads-trapping chamber with a filter array structure. The pneumatic flow control chamber and the beads-trapping chamber are vertically stacked and separated by a thin membrane. By adjusting the pressure in the pneumatic control chamber, the membrane can either be pushed against the filter array to set the device in trapping mode or be released to set the device in releasing mode. In this paper, a computational fluid dynamics simulation was conducted to optimize the geometry design of the filter array structure; the device fabrication was also carried out. The prototype device was tested and the preliminary experimental results showed that it can be used as a beads-trapping unit for various biochemistry and analytical chemistry applications, especially for flow injection analysis systems.
Not Available
An estimated 1.5 billion microbial infections occur globally each year and result in ~4.6 million deaths. A technology gap associated with commercially available diagnostic tests in remote and underdeveloped regions prevents timely pathogen identification for effective antibiotic chemotherapies for infected patients. The result is a trial-and-error approach that is limited in effectiveness, increases risk for patients while contributing to antimicrobial drug resistance, and reduces the lifetime of antibiotics. This paper addresses this important diagnostic technology gap by describing a low-cost, portable, rapid, and easy-to-use microfluidic cartridge-based system for detecting the ESKAPE (Enterococcus faecium, Staphylococcus aureus, Klebsiella pneumoniae, Acinetobacter baumannii, Pseudomonas aeruginosa, and Enterobacter spp.) bacterial pathogens that are most commonly associated with antibiotic resistance. The point-of-care molecular diagnostic system consists of a vacuum-degassed microfluidic cartridge preloaded with lyophilized recombinase polymerase amplification (RPA) assays and a small portable battery-powered electronic incubator/reader. The isothermal RPA assays detect the targeted ESKAPE pathogens with high sensitivity (e.g., a limit of detection of ~10 nucleic acid molecules) that is comparable to that of current PCR-based assays, and they offer advantages in power consumption, engineering, and robustness, which are three critical elements required for the point-of-care setting. This paper describes a portable system for rapidly identifying bacteria in resource-limited environments; we highlight the capabilities of the technology by detecting different pathogens within the ESKAPE collection, which cause nosocomial infections. The system is designed around isothermal DNA-based assays housed within an autonomous plastic cartridge that are designed with the end user in mind, who may have limited technological training. Displaying excellent sensitivity and specificity, the assay systems that we demonstrate may enable future diagnoses of bacterial infection to guide the development of effective chemotherapies and may have a role in areas beyond health where rapid detection is valuable, including in industrial processing and manufacturing, food security, agriculture, and water quality testing.
Premixed charge compression ignition (PCCI) is a promising combustion strategy for reducing in-cylinder NO x and particulate matter formation in diesel engines without incurring fuel penalty. However, one of the challenges in PCCI implementation is that the process does not allow direct control of the combustion timing. The crank angle of 50% heat release, known as the CA50, is generally a reasonable proxy for the quality of combustion in terms of maximum pressure rise rate, combustion noise, and fuel conversion efficiency. This paper outlines the development, and validation, of a real-time capable estimation strategy for diesel-fueled PCCI CA50 using production-viable measurements that do not include in-cylinder pressure. The CA50 estimation strategy considers both stages of diesel-fueled PCCI combustion—low-temperature heat release and high-temperature heat release, which contributes most to the cumulative heat released during combustion. The strategy is validated using a PCCI CA50 dataset generated with a wide range of positions of a variable geometry turbocharge, exhaust gas recirculation fractions, and intake valve closing timings. The model estimates CA50 within ±2 CAD for 65 out of 80 data points and exhibits an error standard deviation of 2.55 CAD.
This data was generated with the ExaWind code suite (https://github.com/Exawind) to investigate the performance of different Active Wake Mixing turbine control in a wind farm situated in a stable atmospheric boundary layer. All cases correspond to a 3x3 wind farm in a 10km x 10km domain using a total mesh size that varied between 1.6 X 10^9 to 1.85 X 10^9 grid cells. The simulations were run across 1800-2000 GPUs on Frontier. The case description and data generation process is fully documented in Yalla, G. R., Brown, K., Cheung, L., Houck, D., deVelder, N., and Balaji, J. (2025). "Estimating annual energy production of wake mixing control strategies including comparisons to wake steering." Wind Energy Sciences (https://doi.org/10.5194/wes-2025-250).
Abstract not provided
Abstract not provided.
Not Available