Phase-contrast imaging with a novel X-ray source

A novel X-ray source based on Parametric X-ray radiation (PXR) has been employed for phase-contrast imaging at the Laboratory for Electron Beam Research and Application (LEBRA), Nihon University, Japan. The PXR X-rays were generated by the 100 MeV electron beam passing through a Si single crystal. The X-rays in the 16approx34 keV range were chosen for imaging of biological samples. The quasi-monochromatic, tunable, and coherent X-ray source is appropriate for this application. In addition, the large X-ray beam irradiation field of approximately 100 mm in diameter, which was achieved without special optics, suggests that the PXR is applicable to imaging for medical diagnostics.

07 ISOTOPE AND RADIATION SOURCES↗

1D X-ray Beam Compressing Monochromators

A total beam compression of 5 and 10 corresponding to the asymmetry angles of 9 deg. and 12 deg. is achieved with V-5 and V-10 monochromators, respectively, in standard single crystal pure germanium (220) X-ray beam compressing (V-shaped) monochromators for CuKalpha{sub 1} radiation. A higher 1D compression of X-ray beam is possible using larger angles of asymmetry, however it is achieved at the expense of the total intensity, which is decreased due to the refraction effect. To increase the monochromator intensity, several ways are considered both theoretically and experimentally. Linearly graded germanium rich Ge{sub x}Si{sub (1-x)} single crystal was used to prepare a V-21 single crystal monochromator with 15 deg. asymmetry angles (compression factor of 21). Its temperature gradient version is discussed for CuKalpha{sub 1} radiation. X-ray diffraction measurements on the graded GeSi monochromator showed more than 3-times higher intensity at the output compared with that of a pure Ge monochromator.

36 MATERIALS SCIENCE↗

Dielectric, magnetic, and lattice dynamics properties of Y-type hexaferrite Ba{sub 0.5}Sr{sub 1.5}Zn{sub 2}Fe{sub 12}O{sub 22}: Comparison of ceramics and single crystals

We prepared multiferroic Y-type hexaferrite Ba{sub 0.5}Sr{sub 1.5}Zn{sub 2}Fe{sub 12}O{sub 22} ceramics and compared their magnetic and dielectric properties with single crystal. Magnetic susceptibility and microwave resonance measurement revealed magnetic phase transition at T{sub C}=312 K, similar as in single crystal. Ferroelectric (FE) phase can be induced by external magnetic field in all investigated samples and the phase diagram in ceramics qualitatively resembles that of the single crystal. The range of magnetic fields, where the FE phase is induced, broadens after annealing of single crystal. Ceramics quenched after sintering exhibit several orders of magnitude lower conductivity than the single crystal. Heavily damped magnetic resonance was discovered in terahertz spectra at 10 K and its frequency softens below 5 GHz near T{sub C}. Number and symmetry of observed infrared (IR) and Raman active phonons correspond to paraelectric phase with D{sub 3d}{sup 5} hexagonal structure. No evidence for a structural phase transition was found in the IR and Raman spectra on cooling (in zero magnetic field) or in the room-temperature IR spectra with external static magnetic field up to 0.3 T.

36 MATERIALS SCIENCE↗

Effect of ultraviolet and x-ray radiation on the work function of TiO{sub 2} surfaces

The work functions of nanocrystalline anatase (TiO{sub 2}) thin films and a rutile single crystal were measured using photoemission spectroscopy (PES). The nanocrystalline titanium dioxide films were deposited in-vacuum using electrospray thin film deposition. A comparison between ultraviolet photoemission spectroscopy (UPS) and low intensity x-ray photoemission spectroscopy (LIXPS) work function measurements on these samples revealed a strong, immediate, and permanent work function reduction (>0.5 eV) caused by the UPS measurements. Furthermore, it was found that regular XPS measurements also reduce the work function after exposure times ranging from seconds to minutes. These effects are similar in magnitude to artifacts seen previously on indium tin oxide (ITO) substrates characterized with XPS and UPS, and are likely related to the formation of a surface dipole through the photochemical hydroxylation of oxygen vacancies present on the TiO{sub 2} surface.

36 MATERIALS SCIENCE↗

Fabrication and subband gap optical properties of silicon supersaturated with chalcogens by ion implantation and pulsed laser melting

Topographically flat, single crystal silicon supersaturated with the chalcogens S, Se, and Te was prepared by ion implantation followed by pulsed laser melting and rapid solidification. The influences of the number of laser shots on the atomic and carrier concentration-depth profiles were measured with secondary ion mass spectrometry and spreading resistance profiling, respectively. We found good agreement between the atomic concentration-depth profiles obtained from experiments and a one-dimensional model for plane-front melting, solidification, liquid-phase diffusion, with kinetic solute trapping, and surface evaporation. Broadband subband gap absorption is exhibited by all dopants over a wavelength range from 1 to 2.5 microns. The absorption did not change appreciably with increasing number of laser shots, despite a measurable loss of chalcogen and of electronic carriers after each shot.

36 MATERIALS SCIENCE↗

Schottky barrier height behavior of Pt-Ru alloy contacts on single-crystal n-ZnO

We investigated the Schottky barrier height (SBH) behavior of binary alloy Schottky contacts on n-type zinc oxide (n-ZnO) single crystals. Pt-Ru alloy electrodes were deposited on the Zn-polar and O-polar faces of ZnO substrates by combinatorial ion-beam deposition under identical conditions. The crystal structures of the Pt-Ru alloy film changed from the Pt phase (cubic structure) to the Ru phase (hexagonal structure) in the Pt-Ru alloy phase diagram with decreasing Pt content. The SBH, determined from current-voltage measurements, decreased with decreasing Pt content, indicating that the SBH behavior also followed the Pt-Ru alloy phase diagram. The alloy electrodes on the Zn-polar face showed better Schottky properties than those on the O-polar face. Hard x-ray photoelectron spectroscopy revealed a difference in the interface oxidization of the Pt-Ru alloy: the interface of the O-polar face and Pt-Ru mixed phase with poor crystallinity had a more oxidized layer than that of the Zn-polar face. As a result of this oxidization, the O-polar face, Pt-Ru mixed, and Ru phases showed poor Schottky properties.

36 MATERIALS SCIENCE↗

Wurtzite structure Sc{sub 1-x}Al{sub x}N solid solution films grown by reactive magnetron sputter epitaxy: Structural characterization and first-principles calculations

AlN(0001) was alloyed with ScN with molar fractions up to {approx}22%, while retaining a single-crystal wurtzite (w-) structure and with lattice parameters matching calculated values. Material synthesis was realized by magnetron sputter epitaxy of thin films starting from optimal conditions for the formation of w-AlN onto lattice-matched w-AlN seed layers on Al{sub 2}O{sub 3}(0001) and MgO(111) substrates. Films with ScN contents between 23% and {approx}50% exhibit phase separation into nanocrystalline ScN and AlN, while ScN-rich growth conditions yield a transformation to rocksalt structure Sc{sub 1-x}Al{sub x}N(111) films. The experimental results are analyzed with ion beam analysis, x-ray diffraction, and transmission electron microscopy, together with ab initio calculations of mixing enthalpies and lattice parameters of solid solutions in wurtzite, rocksalt, and layered hexagonal phases.

36 MATERIALS SCIENCE↗

Optimization of Ferroelectric Ceramics by Design at the Microstructure Level

Ferroelectric materials show remarkable physical behaviors that make them essential for many devices and have been extensively studied for their applications of nonvolatile random access memory (NvRAM) and high-speed random access memories. Although ferroelectric ceramics (polycrystals) present ease in manufacture and in compositional modifications and represent the widest application area of materials, computational and theoretical studies are sparse owing to many reasons including the large number of constituent atoms. Macroscopic properties of ferroelectric polycrystals are dominated by the inhomogeneities at the crystallographic domain/grain level. Orientation of grains/domains is critical to the electromechanical response of the single crystalline and polycrystalline materials. Polycrystalline materials have the potential of exhibiting better performance at a macroscopic scale by design of the domain/grain configuration at the domain-size scale. This suggests that piezoelectric properties can be optimized by a proper choice of the parameters which control the distribution of grain orientations. Nevertheless, this choice is complicated and it is impossible to analyze all possible combinations of the distribution parameters or the angles themselves. Hence we have implemented the stochastic optimization technique of simulated annealing combined with the homogenization for the optimization problem. The mathematical homogenization theory of a piezoelectric medium is implemented in the finite element method (FEM) by solving the coupled equilibrium electrical and mechanical fields. This implementation enables the study of the dependence of the macroscopic electromechanical properties of a typical crystalline and polycrystalline ferroelectric ceramic on the grain orientation.

36 MATERIALS SCIENCE↗

Recent Findings on the Mechanical Responses of Nanostructures to Extreme Loading Conditions

A systematic investigation is being performed to understand the combined size, loading rate and thermal effects on the responses of nanostructures such as nanofilms and nanowires. This paper summarizes what has been found so far, and presents the recent molecular dynamics simulations of the mechanical behaviors of single crystal fcc nanowires and nanofilms under different temperatures and extremely high strain rates. Based on the model-based simulation results, the mechanism of the nanostructural responses will be explored and future research tasks will be discussed.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

LuAG:Ce fibers for high energy calorimetry

The main objective of this contribution is to point out the potentialities of cerium doped LuAG single crystal as pixels and fibers. We first show that after optimization of growth conditions using Bridgman technology, this composition exhibits very good performances for scintillating applications (up to 26 000 photons/MeV). When grown with the micropulling down technology, fiber shapes can be obtained while the intrinsic performances are preserved. For the future high energy experiments requiring new detector concepts capable of delivering much richer informations about x- or gamma-ray energy deposition, unusual fiber shaped dense materials need to be developed. We demonstrate in this frame that cerium doped LuAG is a serious candidate for the next generation of ionizing radiation calorimeters.

36 MATERIALS SCIENCE↗

Luminescence and creation of electron centers in UV-irradiated YAlO{sub 3} single crystals

Luminescence and defect creation processes were studied by the photoluminescence, thermally stimulated luminescence, and electron paramagnetic resonance methods in the UV-irradiated single crystals of undoped YAlO{sub 3}, containing small amounts of Ce, Mo, and Ti ions as accidental impurities. The luminescence of the electron antisite Y{sub Al}{sup 2+}-type centers of different structures was found around 2.45 eV and studied at 4.2-500 K. The luminescence of the Ti{sup 3+}-related centers (2.03 and 1.73 eV) and Ti{sup 4+} centers (2.78 eV) was observed as well. Dependences of the number of the Y{sub Al}{sup 2+}-type and Ti{sup 3+}-related centers on the UV irradiation energy, temperature, and duration, as well as on various crystal heat-treatment procedures were examined. As a result of the photostimulated electron transfer from the O{sup 2-} ligand ions to Mo{sup 4+} and Ti{sup 4+} ions, the paramagnetic hole O{sup -}-type centers and electron Ti{sup 3+} and Mo{sup 3+} centers are created. The antisite Y{sub Al}{sup 2+}-type centers are created due to the photostimulated release of electrons mainly from the Mo{sup 3+} centers to the conduction band and their subsequent trapping at the Y{sub Al}{sup 3+} ions located near an oxygen vacancy or a defect at the neighboring Y{sup 3+} site.

36 MATERIALS SCIENCE↗

Effect of pre-existing disorder on surface amorphization in GaN

Single crystal GaN epilayers with pre-existing surface disordered layers are bombarded at room temperature with 40 and 100 keV P ions. Stable lattice defects are studied by Rutherford backscattering/channeling spectrometry. Results show that the rate of planar surface amorphization is independent of the concentration of pre-existing defects near the amorphous/crystalline (a/c) interface. In contrast, the formation of stable defects in the crystal bulk in the vicinity of an a/c interface is influenced by the presence of the interface. These experimental observations suggest that the a/c interface, as compared to stable bulk damage, is a more efficient sink for mobile point defects with respect to both processes of point defect recombination and trapping.

36 MATERIALS SCIENCE↗

Submicrometer Single Crystal Diffractometry for Highly Accurate Structure Determination

Submicrometer single crystal diffractometry for highly accurate structure determination was developed using the extremely stable and highly brilliant synchrotron radiation from SPring-8. This was achieved using a microbeam focusing system and the submicrometer precision low-eccentric goniometer system. We demonstrated the structure analyses with 2x2x2 {mu}m{sup 3} cytidine, 600x600x300 nm{sup 3} BaTiO{sub 3}, and 1x1x1 {mu}m{sup 3} silicon. The observed structure factors of the silicon crystal were in agreement with the structure factors determined by the Pendelloesung method and do not require absorption and extinction corrections.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diamond Beamline I16 (Materials and Magnetism)

We describe the key features and performance specifications of a facility for high-resolution single-crystal x-ray diffraction at Diamond Light Source. The scientific emphasis of the beamline is materials- and x-ray-physics, including resonant and magnetic scattering. We highlight some of the more novel aspects of the beamline design.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Preliminary Commissioning and Performance of the Soft X-ray Micro-characterization Beamline at the Canadian Light Source

The Soft X-ray Micro-characterization Beamline (SXRMB) is a medium energy, bending magnet based beamline, designed to cover an energy range of 1.7-10 keV using two sets of crystals--InSb(111) and Si(111). The design goal is to deliver a flux of 2x10{sup 11} photons sec{sup -1}/100 mA with a resolution up to 10,000 for X-ray Absorption Spectroscopy. A KB mirror stage is designed to provide microprobe capability, with a spot size of 10x10 {mu}m{sup 2} and a flux of >10{sup 9} at the microprobe station. The beamline has been in the commissioning phase since 2008, and access to the X-ray absorption endstation is now open to general users. The optical commissioning and performance of the beamline is presented with some early experimental results.

43 PARTICLE ACCELERATORS↗

Optimizing the XMaS Beamline for Low energy Operations to Maximize Benefits from the ESRF Upgrade Program

The XMaS beamline at the ESRF has been in regular user operation since April 1998 and operates over an energy range of 2.4-15 keV. It has developed a wide range of unique instrumentation, primarily dedicated to high resolution magnetic and single crystal diffraction. With the upcoming ESRF upgrade program a number of instrumental developments are planned for the beamline to maximize the benefits of the increased photon flux at low energies. Firstly we report on the optimisation of the beamline and its core components. A novel attenuator system which is actuated by fast acting solenoids thereby avoiding problems of gas bursts into the beamline vacuum seen on some commercially available instruments is introduced. Secondly we discuss developments to the low temperature sample environments that have been integrated into the beamline vacuum system, minimizing both air and beryllium absorption. Finally we demonstrate the current capabilities of the beamline by describing preliminary reflectivity measurements that have been made on an [Fe(2ML)Pd(15ML)]x20 multilayer recorded around the Pd L{sub 3} edge using circular polarised light produced from a thin diamond phase plate.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Continuous Flow Cryostat for X-Ray Fluorescence

A continuous Helium flow cryostat was designed and built by Cryovac GMbH to specifications given by ESRF beamline ID26. The beamline has constructed a high energy resolution X-ray emission spectrometer using multiple spherically bent analyser crystals, together with the sample and detector on a vertical Rowland circle. The double shrouded cryostat has a low profile designed to fit into the spectrometer setup, the lowest detector position allows for a Bragg angle of 85 degrees with a 1 meter diameter Rowland circle. The cryostat has a temperature range of 5 to 300 Kelvin on the sample holder which is cooled by static Helium exchange gas. The cryostat has triple windows for beam entrance, transmission and fluorescence; the latter offers an opening angle of 80 degrees horizontally and 50 degrees vertically. The cryostat can be configured to work in two different operation modes: translation or rotation. The translation mode offers a displacement of 50 mm to accommodate multiple samples on the sample holder. The rotation mode is used for polarisation studies on single crystals.We show recent results obtained on Chromium containing molecular complexes; data collection was done at a temperature of 10 Kelvin to avoid radiation damage.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Optimization of Cylindrical Bent Crystals with Small Radius

To minimize the anticlastic curvature and lower the breaking risk of a sagittal bent crystal with a smaller bending radius, three types of crystal models including the stiffening ribs, the golden value and the assembly with metal were discussed in this paper. Overall structures of the models were predicted and the parameters were optimized by the finite element analysis method. Compared with the results of measurement by long-trace-profiler, theoretical calculations were in good agreed with practical tests. The single-crystal silicon strips glued on the titanium is preferred for the second crystal of the sagittal focusing monochromator at the NSRL-XAFS beamline. Because it not only minimizes the anticlastic distortion but also it achieves small radius less than one meter.