Search NASA⌕ Search

SEARCH · Search NASA

Results for “Operational Amplifier”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Peru Health and Air Quality II: Leveraging Earth Observations and Health Data to Map Outbreak Risk and Inform Public Health Interventions for Zoonotic Disease Prevention

Peru's Madre de Dios region is a hotspot for dengue fever and leishmaniasis due to its tropical Amazonian climate. Though treatable, these zoonotic diseases are debilitating for under-resourced communities whose already close proximity to mosquito and sandfly vectors continues to increase via rapid urbanization and deforestation. Peru’s Ministries of Health (MINSA) and Environment (MINAM) are working to better understand the environmental factors amplifying the risk of dengue fever and leishmaniasis transmission. The first term of this project classified the land use and land cover of Madre de Dios’ 11 districts for 2010, 2015, and 2020 and identified a correlation between both diseases and urbanization. Our team expanded this analysis by creating urban-forest edge maps and incorporating climatic and topographic variables with data from Landsat 7 Enhanced Thematic Mapper Plus (ETM+), Landsat 8 Operational Land Imager (OLI), the Global Precipitation Measurement (GPM) Integrated Multi-satellitE Retrievals for GPM (IMERG), and the Shuttle Radar Topography Mission (SRTM). We determined these variables’ impacts on disease incidence by assessing existing literature and running regression models. Dengue fever correlated with urban-forest edge, urban area, slope, temperature, and precipitation. Leishmaniasis primarily correlated with forest-edge area and elevation, but lacking additional statistical significance prevented further work, a decision supported by the literature. Thus, the risk matrix and risk map which we scripted in R to visualize the risk of disease posed to districts alongside health post locations addresses only dengue fever. The results and products will inform MINSA and MINAM in public health interventions, resource distribution, and policy initiatives.

Jennifer Rogers↗

Recent Upgrade of the Klystron Modulator at SLAC

The SLAC National Accelerator Laboratory employs 244 klystron modulators on its two-mile-long linear accelerator that has been operational since the early days of the SLAC establishment in the sixties. Each of these original modulators was designed to provide 250 kV, 262 A and 3.5 {mu}S at up to 360 pps using an inductance-capacitance resonant charging system, a modified type-E pulse-forming network (PFN), and a pulse transformer. The modulator internal control comprised of large step-start resistor-contactors, vacuum-tube amplifiers, and 120 Vac relays for logical signals. A major, power-component-only upgrade, which began in 1983 to accommodate the required beam energy of the SLAC Linear Collider (SLC) project, raised the modulator peak output capacity to 360 kV, 420 A and 5.0 {mu}S at a reduced pulse repetition rate of 120 pps. In an effort to improve safety, performance, reliability and maintainability of the modulator, this recent upgrade focuses on the remaining three-phase AC power input and modulator controls. The upgrade includes the utilization of primary SCR phase control rectifiers, integrated fault protection and voltage regulation circuitries, and programmable logic controllers (PLC) -- with an emphasis on component physical layouts for safety and maintainability concerns. In this paper, we will describe the design and implementation of each upgraded component in the modulator control system. We will also report the testing and present status of the modified modulators.

43 PARTICLE ACCELERATORS↗

Synchronizing femtosecond laser with x-ray synchrotron operating at arbitrarily different frequencies

The ability to synchronize a femtosecond laser to x-ray pulses is crucial for performing ultrafast time-resolved x-ray scattering experiments at synchrotrons. Conventionally, the task has been achieved by locking a harmonic frequency of the laser oscillator to the storage ring master radio-frequency (RF). However, when the frequency mismatch between the two sources cannot be compensated by small adjustments to the laser cavity length, synchronization to a harmonic frequency requires modifying the optical components of the laser system. We demonstrate a novel synchronization scheme, which is a flexible alternative for synchronizing these two sources operating at arbitrarily different frequencies. First, we find the greatest common divisor (GCD) of the two frequencies that is still within the limited tuning range of the laser cavity length. The GCD is generated by dividing down from the storage ring RF, and is separately multiplied up to provide a feedback signal for synchronizing the laser cavity. Unique to our scheme, the GCD also serves as a harmonic RF source for the laser amplifier such that only laser oscillator pulses at fixed integer multiples of the storage ring RF are selected for amplification and delivery to experiments. Our method is implemented at the Photon Test Facility beamline of Pohang Light Source where timing-jitter less than 4 ps (r.m.s.) is measured using a new shot-to-shot method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Highly efficient non-degenerate four-wave mixing under dual-mode injection in InP/InAs quantum-dash and quantum-dot lasers at 1.55 μm

This work reports on non-degenerate four-wave mixing under dual-mode injection in metalorganic vapor phase epitaxy grown InP/InAs quantum-dash and quantum dot Fabry-Perot laser operating at 1550 nm. High values of normalized conversion efficiency of −18.6 dB, optical signal-to-noise ratio of 37 dB, and third order optical susceptibility normalized to material gain χ{sup (3)}/g{sub 0} of ∼4 × 10{sup −19} m{sup 3}/V{sup 3} are measured for 1490 μm long quantum-dash lasers. These values are similar to those obtained with distributed-feedback lasers and semiconductor optical amplifiers, which are much more complicated to fabricate. On the other hand, due to the faster gain saturation and enhanced modulation of carrier populations, quantum-dot lasers demonstrate 12 dB lower conversion efficiency and 4 times lower χ{sup (3)}/g{sub 0} compared to quantum dash lasers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Review of the Oak Ridge National Laboratory (ORNL) Neutronic Calculations Regarding the Conversion of the High Flux Isotope Reactor (HFIR) to the Use of Low Enriched Uranium (LEU) Fuel

In awareness of the risk caused by the proliferation of nuclear materials, the international community initiated in 1978 the Reduced Enrichment for Research and Test Reactors (RERTR) Program. The goal of the RERTR program is to seek solutions to convert the reactors using High Enriched Uranium (HEU) fuel ( 235 U/U ≥ 20 wt. %) to the use of Low Enriched Uranium (LEU) Fuel ( 235 U/U < 20 wt. %). Among the 200 reactors worldwide currently in the scope of the program, about 70 have been converted or shut down prior to conversion. In the U.S., six high reactors remain to be converted. One of the U.S. reactors is the High Flux Isotope Reactor (HFIR) located at Oak Ridge National Laboratory (ORNL). This multipurpose reactor is mainly used for neutron scattering experiments and isotope production. It has two fuel elements made of involute-shaped fuel plates. The ORNL Research Reactor Division (RRD) has prepared during FY2011 two series of calculations, one neutronic and one thermal-hydraulic (TH), in support of the conversion activities for HFIR. The neutronic calculations cover mainly the evaluation of the matrix of performance (cycle length and flux), the distribution of power in the fuel elements, kinetics parameters and reactivity coefficients. As defined by the RRD procedures, the calculations have to be reviewed. Per internal decision, the RRD proposed an external reviewer, Argonne National Laboratory (ANL). The results of the Argonne neutronic review are presented in this report. The results of the TH review are presented in a separate report. The main conclusion of the ORNL reactor physics analyses is that the proposed reference HFIR LEU core (using the so-called monolithic UMo fuel) could maintain the current level of performance (obtained with a HEU core at 85MW) if it is operated at 100MW. However, to operate within the same safety limits as the current HEU core, the thermal hydraulic analyses show that the peaking of the power distribution occurring at the bottom of the fuel plates has to be reduced. The RRD has found a potential solution by reducing the fuel thickness at the bottom of the fuel plate. This would require addition of an axial grading to the already radially-graded fuel. Thus, the review has been focused on independently recalculating all of the ORNL calculations and making an as fair as possible comparison between the current 85MW HEU core and the reference 100MW LEU core design. ORNL and ANL have used the same computational tools to perform the work. The codes MCNP and ORIGEN have been used to perform the steady state and depletion calculations, respectively. The communication between the two codes has been carried out by the code VESTA. Even though the code MCNP is able to handle complex geometries, it cannot model the involute shape. Nonetheless, ANL has developed an innovative methodology to model the involute shape with MCNP with an approximation that can be made as accurate as desired. Thus, ANL has been able to perform the calculations using an explicit (or discrete) description of the fuel elements. The current modeling used by ORNL consists in homogenizing the different fuel element components (cladding, fuel, coolant…). Although this method is easier to implement, it may also affect the reactor physics which may have an impact on the calculated results. Even though some differences in the physics parameters (flux for instance) have been detected between the HEU explicit (ANL) and homogenized (ORNL) models, they are small enough to not significantly impact the performance parameters. However, this is not the case for the LEU core where the differences in the physics parameters lead to significant differences in the performance parameters, especially the cycle length (found to be considerably longer in the explicit model). Nonetheless, the others parameters calculated by ANL (power distribution, kinetics parameters…) are in good agreement with those calculated by ORNL. Some inconsistencies have been detected in the original ORNL inputs that have been corrected in the reference ones used by ANL for the review and, therefore, the cycle length difference between the LEU homogenized and explicit models has been amplified. Consequently, the ANL comparison of the HFIR HEU and LEU cores has given different results than the ORNL results. The ORNL matrix of performance for the 100MW LEU reference design shows that the reactor cycle length would be as long and the flux as high as the current 85MW HEU core. In contrast, the ANL matrix of performance shows that the 100MW LEU design would have a significantly longer cycle length (~33days) than the current 85MW HEU core (~25days). In addition, it has been shown that, if the reactor is operated for 33days, the neutron fluence would be high enough to increase the overall reactor performance by a significant factor. If the reactor is forced to shut down after 25days, calculations show that the neutron flux would be high enough to maintain the performance of the neutron scattering experiments but losses are predicted to occur in several irradiation facilities. Increasing the cycle length may not be possible for other reasons. For instance, a longer cycle length can increase the cumulative oxide layer thickness growth on the plate. The increase in the neutron fluence may affect the lifetime of the reactor vessel and, by reducing the time for maintenance, pose operational challenges. An assessment of these as well as other potential questions associated with a 33 day cycle length is needed. Since such an assessment has not been carried out, ANL cannot conclude that the ORNL reference LEU core should or could operate at 100MW. The conclusions of the ANL review are different than those of the ORNL investigation mainly because the explicit and homogenized methodologies used to model the core are different. In this report, an attempt is made to justify and explain as clearly as possible why the ANL methodology is thought to be better suited for HFIR analyses. It is acknowledged that because the ANL and ORNL LEU models have not been benchmarked against experiments, it is possible that doubts could be raised concerning the ability of the models to correctly capture all of the physics behavior of the reactor.

Bergeron, A.↗

Low-frequency self-pulsing in single-section quantum-dot laser diodes and its relation to optothermal pulsations

Self-sustained pulsations in the output of an InAs quantum dot laser diode in the MHz range are reported. The characteristics (shape, range, and frequency) are presented for the free-running laser and when optical feedback in the Littrow configuration is applied. Bistability in the light-current characteristics is observed for operating wavelengths smaller than the gain peak, but it is not present for wavelengths above the gain peak and for the free-running laser, except at elevated temperatures. The temporal evolution of the envelopes of the optical spectra is very different for operation below, around, and above the gain peak, which might be related to a change of phase-amplitude coupling across the gain maximum, in agreement with the expectation for a two-level system. The time scale and the bifurcation scenario, supported by an initial blueshift of the emission wavelength of each longitudinal mode in time-resolved optical spectra, suggests that these are optothermal pulsations similar to those reported in quantum well amplifiers [Phys. Rev. E 68, 036209 (2003)]. The mechanism of pulsation seems to be a destabilization of bistable states (due to saturable absorption in the beam wings) by a slow thermal change in the waveguiding properties.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Focal Plane Array Low Background Testing (Focal Plane Array Characterization under a Low Background)

Most infra-red (IR) imagers for tactical applications use a direct injection (DI) input amplifier design. Fewer transistors in the unit cell allow the read-out electronic circuit (ROIC) to be minimized. This allows either more room for charge integration capacitors or finer pixel pitches. These ROICs work well at high background irradiance levels. However, at low background irradiance levels photocurrent inject efficiency for a DI unit cell amplifier is reduced. Some models have shown that this efficiency can drastically affect performance under low background conditions. The main benefit for Sandia National Laboratories (SNL) and L-3 Communications Cincinnati Electronics (L-3) was a better understanding of these types of sensors under low background conditions. It also provided the opportunity for an independent analysis of these sensors. The purpose of this project was to measure DI for low light levels under different operating temperatures of the L-3 CE103 a 1280 x 1024 indium antimonide 15 micron pitch detector. Results showed DI efficiency approaches 75% under extremely low light levels. Additionally, measured data didn't conform well to traditional circuit based models indicated that other effects are contributing to DI efficiency. A "spot scanning" PSF measurement was also conducted to measure pixel-to-pixel crosstalk for this array. Spot scanning data showed near ideal performance.

47 OTHER INSTRUMENTATION↗

Fissile material holdup measurement systems: an historical review of hardware and software

The measurement of fissile material holdup is accomplished by passively measuring the energy-dependent photon flux and/or passive neutron flux emitted from the fissile material deposited within an engineered process system. Both measurement modalities--photon and neutron--require the implementation of portable, battery-operated systems that are transported, by hand, from one measurement location to another. Because of this portability requirement, gamma-ray spectrometers are typically limited to inorganic scintillators, coupled to photomultiplier tubes, a small multi-channel analyzer, and a handheld computer for data logging. For neutron detection, polyethylene-moderated, cadmium-back-shielded He-3 thermal neutron detectors are used, coupled to nuclear electronics for supplying high voltage to the detector, and amplifying the signal chain to the scaler for counting. Holdup measurement methods, including the concept of Generalized Geometry Holdup (GGH), are well presented by T. Douglas Reilly in LA-UR-07-5149 and P. Russo in LA-14206, yet both publications leave much of the evolutionary hardware and software to the imagination of the reader. This paper presents an historical review of systems that have been developed and implemented since the mid-1980s for the nondestructive assay of fissile material, in situ. Specifications for the next-generation holdup measurements systems are conjectured.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mu2e Calorimeter Readout System

The Mu2e electromagnetic calorimeter is made of two disks of un-doped parallelepiped CsI crystals readout by SiPM. There are 674 crystals in one disk and each crystal is readout by an array of two SiPM. The readout electronics is composed of two types of modules: (1) the front-end module hosts the shaping amplifier and the high voltage linear regulator; since one front-end module is interfaced to one SiPM, a total of 2696 modules are needed for the entire calorimeter; (2) a waveform digitizer provides a further level of amplification and digitizes the SiPM signal at the sampling frequency of 200MHz with 12-bits ADC resolution; since one board digitizes the data received from 20 SiPMs, a total of 136 boards are needed. The readout system operational conditions are hostile: ionization dose of 20krads , neutron flux of 10 12 n(1MeVeq)/cm 2 , magnetic field of 1T and in vacuum level of 10 -4 Torr . A description of the readout system and qualification tests is reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photon acceleration in the amplified plasma density wake of two copropagating laser pulses

Photon acceleration of a laser pulse occurs in a medium with a space and time-varying permittivity. Using Hamiltonian formulation, a theoretical study of the frequency upshift of a probe laser pulse, which is considered as a 'quasiphoton' or 'test particle,' propagating through an amplified plasma density wake of two copropagating laser pulses, is presented. The linear superposition of wakefields studied using an analytical model shows that the presence of a controlling pulse amplifies the wake of a driver pulse. The amplified wake amplitude can be controlled by varying the delay between the two pulses. Two-dimensional particle-in-cell simulations demonstrate wake superposition due to the two copropagating laser pulses. A phase space analysis shows that the probe photon can experience a significant frequency upshift in the amplified density wake. Furthermore, the range of photon frequencies trapped and accelerated is determined by the amplitude of the density wake.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-resolution radiation detection using Ni/SiO 2 /n-4H-SiC vertical metal-oxide-semiconductor capacitor

In this article, we demonstrate the radiation detection performance of vertical metal-oxide-semiconductor (MOS) capacitors fabricated on 20 μm thick n-4H-SiC epitaxial layers with the highest energy resolution ever reported. The 100 nm SiO2 layer was achieved on the Si face of n-4H-SiC epilayers using dry oxidation in air. The Ni/SiO2/n-4H-SiC MOS detectors not only demonstrated an excellent energy resolution of 0.42% (ΔE/E 100) for 5.48 MeV alpha particles but also caused a lower enhancement in the electronic noise components of the spectrometer compared with that observed for the best high-resolution Schottky barrier detectors. The MOS detectors also exhibited a high charge collection efficiency (CCE) of 96% at the optimized operating bias despite the presence of the oxide layer. A drift-diffusion model applied to the CCE vs gate bias voltage data revealed a minority (hole) carrier diffusion length of 24 μm. Capacitance mode deep level transient spectroscopy (C-DLTS) scans in the temperature range 84–800 K were carried out to identify the resolution limiting electrically active defects. Interestingly, the C-DLTS spectra revealed both positive and negative peaks, indicating the simultaneous presence of electron (majority) and hole (minority) trap centers. It has been inferred that at the steady-state bias for the C-DLTS measurement, the MOS detector operates in the inversion mode at certain device temperatures, causing holes to populate the minority trap centers and, hence, manifests minority carrier peaks as well.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

FAST MAGNETIC FIELD AMPLIFICATION IN THE EARLY UNIVERSE: GROWTH OF COLLISIONLESS PLASMA INSTABILITIES IN TURBULENT MEDIA

In this work we report on a numerical study of the cosmic magnetic field amplification due to collisionless plasma instabilities. The collisionless magnetohydrodynamic equations derived account for the pressure anisotropy that leads, in specific conditions, to the firehose and mirror instabilities. We study the time evolution of seed fields in turbulence under the influence of such instabilities. An approximate analytical time evolution of the magnetic field is provided. The numerical simulations and the analytical predictions are compared. We found that (i) amplification of the magnetic field was efficient in firehose-unstable turbulent regimes, but not in the mirror-unstable models; (ii) the growth rate of the magnetic energy density is much faster than the turbulent dynamo; and (iii) the efficient amplification occurs at small scales. The analytical prediction for the correlation between the growth timescales and pressure anisotropy is confirmed by the numerical simulations. These results reinforce the idea that pressure anisotropies—driven naturally in a turbulent collisionless medium, e.g., the intergalactic medium, could efficiently amplify the magnetic field in the early universe (post-recombination era), previous to the collapse of the first large-scale gravitational structures. This mechanism, though fast for the small-scale fields (∼kpc scales), is unable to provide relatively strong magnetic fields at large scales. Other mechanisms that were not accounted for here (e.g., collisional turbulence once instabilities are quenched, velocity shear, or gravitationally induced inflows of gas into galaxies and clusters) could operate afterward to build up large-scale coherent field structures in the long time evolution.

79 ASTRONOMY AND ASTROPHYSICS↗

Laser Velocimeter for Studies of Microgravity Combustion Flowfields

A velocimeter was developed based on modulated filtered Rayleigh scattering (MFRS). The MFRS velocimeter was successfully demonstrated by making one-component velocity measurements in a supersonic expansion using molecular Rayleigh scattering in a jet of N2. These measurements were made in a sweep mode where the Rayleigh scattered profile is cross-correlated with absorption in a static cell to determine velocity. To improve temporal resolution the frequency-locked mode of operation was developed, with an in-situ referencing scheme to compensate for signal fluctuations arising from density variations in the probe volume. Spectroscopic grade (i.e. continuously tunable, single-mode) laser sources with high power (greater than 100 mW) are not commercially available at the wavelength of interest (780 nm). We developed an all-solid-state system with a low power (approximately 10 mW) spectroscopic grade laser source in a Littrow cavity is amplified by a broad-area diode laser. We have demonstrated that the slaved output tracks the injected input but have not yet demonstrated power gain by the end of the grant period.

Varghese, Philip L.↗

Ka-Band TWT High-Efficiency Power Combiner for High-Rate Data Transmission

A four-port magic-T hybrid waveguide junction serves as the central component of a high-efficiency two-way power combiner circuit for transmitting a high-rate phase-modulated digital signal at a carrier frequency in the Ka-band (between 27 and 40 GHz). This power combiner was developed to satisfy a specific requirement to efficiently combine the coherent outputs of two traveling-wavetube (TWT) amplifiers that are typically characterized by power levels on the order of 100 W or more. In this application, the use of a waveguide-based power combiner (instead of a coaxial-cable- or microstrip-based power combiner, for example) is dictated by requirements for low loss, high power-handling capability, and broadband response. Combiner efficiencies were typically 90 percent or more over both the linear and saturated output power regions of operation of the TWTs . Figure 1 depicts the basic configuration of the magic-T hybrid junction. The coherent outputs of the two TWTs enter through ports 1 and 4. As a result of the orientations of the electromagnetic fields, which also provides a needed high port-to-port isolation, of these two input signals and the interior design of the magic-T junction, the input powers are divided so as to add in phase at one output port (port 2), and to be opposite in phase and hence cancel each other at the opposite coplanar output port (port 3). The net result is that the output power at port 2 is essentially double that of the output of one TWT, minus the power lost in the magic-T hybrid junction. Optimum performance as a high-efficiency power combiner thus requires a balance of both power and phase at the input ports of the magic-T. Replicas of this two-way combiner can be arranged in a binary configuration to obtain a 2n-way (where n is an integer) combiner. For example, Figure 2 illustrates the use of three two-way combiners to combine the outputs of four TWTs.

Wintucky, Edwin G.↗

Gifford-McMahon/Joule-Thomson Refrigerator Cools to 2.5 K

A compact refrigerator designed specifically for cooling a microwave maser low-noise amplifier is capable of removing heat at a continuous rate of 180 mW at a temperature of 2.5 K. This refrigerator is a combination of (1) a commercial Gifford-McMahon (GM) refrigerator nominally rated for cooling to 4 K and (2) a Joule-Thomson (J-T) circuit. The GM refrigerator pre-cools the J-T circuit, which provides the final stage of cooling. The refrigerator is compact and capable of operating in any orientation. Moreover, in comparison with a typical refrigerator heretofore used to cool a maser to 4.5 K, this refrigerator is simpler and can be built at less than half the cost.

Britcliffe, Michael↗

Comprehensive Radiation Testing of Uncooled, Free Space Coupled, InGaAs Quad Photoreceivers

We have comprehensively tested uncooled, free space coupled, InGaAs Quad Photoreceivers having 0.5mm, 1mm, and 2mm diameter integrated with a low noise transimpedance amplifier (TIA)using 30MeV Protons, 100MeV Protons, 662keV Gamma Rays, 1GeV/n Helium, and 1GeV/n Iron at room temperature of ~20°C.These devices find multiple applications in space for differential wave front sensing as part of a Gravitational Wave Observatory, as well as instrumentation and control for next generation space telescopes. The bandwidth of all receivers was 20MHz which was TIA limited. All 0.5mm and 1mm devices were found to be fully functional at normal operating conditions and at room temperature for Protons, Gamma Rays, 1GeV/n Helium, and 1GeV/n Iron. Only one quadrant of a 2mm In GaAs Quad had hard failure due to 1GeV/n Helium Ions; otherwise it too survived all other radiation tests. Detailed test results follow in the manuscript including recommendations for future space flights. These radiation test results, combined with the earlier successful mechanical shock and vibration testing mean these devices have passed preliminary testing for space qualification.

Abhay M Joshi↗

Development and Airborne Demonstration of the Concurrent Artificially-Intelligent Spectrometry and Adaptive Lidar System: Advancing Lidar Capabilities for the STV Observing System

We report on the design, build and planned airborne demonstration of a spaceflight-prototype Concurrent Artificially-intelligent Spectrometry and Adaptive Lidar System (CASALS). The CASALS lidar is an Adaptive Wavelength Scanning Lidar (AWSL) operating in push broom mode. The demonstration has three major goals: advance the Technical Readiness Level of the AWSL hardware, validate its measurement performance and mature algorithms and methods needed for the Surface Topography and Vegetation (STV) observing system. AWSL acquires parallel tracks of surface heights by rapidly steering a laser beam across a swath. A 1040nm-centered laser is tuned across 30nm and carved into 2-ns pulses, the pulse energy is fiber amplified and the pulses are dispersed cross-track using a non-mechanical wavelength-to-angle grating. For the spaceflight system the beam will be pointable to 1200 10m footprints across a 7km swath. For the airborne demonstration there will be 256 0.7m footprints across a 110m swath. In both cases the footprints overlap across- and along-track for uniform target illumination. For the airborne demonstration a steering mirror will increase the accessible swath width to 4km. At the receiver, solar radiation is filtered with a narrow-slit grating-spectrometer and the footprints are imaged onto a linear-mode, photon-sensitive HgCdTe APD-array. The received pulses are time-division-multiplexed to a few high-speed analog-to-digital converters to record waveforms. Spaceflight and airborne CASALS are designed to nominally detect 20 photons per pulse and, by averaging 27 overlapping footprints, achieve 2cm flat target range precision and high-quality vegetation structure waveforms The AWSL will be flown in the summer of 2024, along with a Headwall VNIR-SWIR hyperspectral sensor imaging a 4km wide swath, at NEON eddy covariance flux towers in the U.S. mid-Atlantic where high resolution hyperspectral and lidar data, acquired annually, are available for validation.

Guangning Yang↗

Advanced Systems for Monitoring Underwater Sounds

The term "Passive Acoustic Monitoring System" (PAMS) describes a developmental sensing-and-data-acquisition system for recording underwater sounds. The sounds (more precisely, digitized and preprocessed versions from acoustic transducers) are subsequently analyzed by a combination of data processing and interpretation to identify and/or, in some cases, to locate the sources of those sounds. PAMS was originally designed to locate the sources such as fish of species that one knows or seeks to identify. The PAMS unit could also be used to locate other sources, for example, marine life, human divers, and/or vessels. The underlying principles of passive acoustic sensing and analyzing acoustic-signal data in conjunction with temperature and salinity data are not new and not unique to PAMS. Part of the uniqueness of the PAMS design is that it is the first deep-sea instrumentation design to provide a capability for studying soniferous marine animals (especially fish) over the wide depth range described below. The uniqueness of PAMS also lies partly in a synergistic combination of advanced sensing, packaging, and data-processing design features with features adapted from proven marine instrumentation systems. This combination affords a versatility that enables adaptation to a variety of undersea missions using a variety of sensors. The interpretation of acoustic data can include visual inspection of power-spectrum plots for identification of spectral signatures of known biological species or artificial sources. Alternatively or in addition, data analysis could include determination of relative times of arrival of signals at different acoustic sensors arrayed at known locations. From these times of arrival, locations of acoustic sources (and errors in those locations) can be estimated. Estimates of relative locations of sources and sensors can be refined through analysis of the attenuation of sound in the intervening water in combination with water-temperature and salinity data acquired by instrumentation systems other than PAMS. A PAMS is packaged as a battery-powered unit, mated with external sensors, that can operate in the ocean at any depth from 2 m to 1 km. A PAMS includes a pressure housing, a deep-sea battery, a hydrophone (which is one of the mating external sensors), and an external monitor and keyboard box. In addition to acoustic transducers, external sensors can include temperature probes and, potentially, underwater cameras. The pressure housing contains a computer that includes a hard drive, DC-to- DC power converters, a post-amplifier board, a sound card, and a universal serial bus (USB) 4-port hub.

Lane, Michael↗