Search NASA⌕ Search

SEARCH · Search NASA

Results for “Surface sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Ab initio molecular dynamics with enhanced sampling in heterogeneous catalysis

Ab initio molecular dynamics simulations combined with enhanced sampling techniques are becoming widespread methods to investigate chemical phenomena in catalytic systems. These techniques automatically include finite temperature effects, anharmonicity, and collective dynamics in their robust description of enthalpic and entropic contributions, which can have significant impact on reaction free energy landscapes. This contrasts with standard ab initio static approaches that are based on assessing reaction free energies from various coarse-grained descriptions of the reaction potential energy surface. Enhanced sampling ab initio molecular dynamics opens the way to first principles simulations of systems of increasing complexity like solid/liquid catalytic interfaces. Here, we aim at guiding the reader through the basis of these techniques, summarizing their fundamental theoretical and practical aspects, and reviewing the relevant literature in the field. After a brief introduction to the problem, we will illustrate the advantage of using molecular simulations to include finite temperature effects, examine the most common ab initio techniques currently in use, describe their application to solid state heterogeneous catalysts, and finally critically review the most popular enhanced sampling techniques used in computational catalysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rate/Concentration Kinetic Petals: A Transient Method to Examine the Interplay of Surface Reaction Processes

Transient pulse response experiments are used to construct rate/concentration (RC) kinetic dependencies—RC petals—and provide a new method to distinguish the timing and interplay of adsorption, surface reaction, and product formation on complex (industrial) materials. A petal shape arises as the dynamic “reaction-diffusion” experiment forces the concentration and reaction rate to return to zero. In contrast to the typical steady-state “Langmuir-type” RC dependence, RC petals have two branches, which arise as a result of decoupled gas and surface concentrations in the non-steady-state regime. To demonstrate this approach, the characteristics of petal shapes using ammonia decomposition as a probe reaction are presented. Ammonia, hydrogen, and nitrogen transformation rates are compared on three simple materials: Fe, Co, and a bimetallic CoFe preparation when ammonia is pulsed at 550°C in a low-pressure diffusion reactor. All materials demonstrate a two-branch kinetic RC dependence for ammonia adsorption, and rate constants are quantified in the low-coverage regime. We found that H 2 and N 2 product formation was dependent on the concentration of surface intermediates for all materials with one exception: for Co, an additional fast hydrogen generation process was observed; the rate of which coincided with ammonia adsorption. Nitrogen generation was only significant for CoFe and Co and on the CoFe catalyst, a self-inhibition property was observed. A method for estimating the number of active sites based on the RC petals is presented and was applied to the Fe and CoFe samples. The surface coverage and rate of formation/conversion of surface intermediates are interpreted from the examination of shape characteristics of the RC petals for each material.

36 MATERIALS SCIENCE↗

The Influence of Mineralogy on Recovering Organic Acids from Mars Analogue Materials Using the One-Pot Derivatization Experiment on the Sample Analysis at Mars(SAM) Instrument Suite

The search for complex organic molecules on Mars, including important biomolecules such as amino acids and carboxylic acids, will require a chemical extraction and a derivatization step to transform these organic compounds into species that are sufficiently volatile to be detected by gas chromatography mass spectrometry (GCMS). We have developed a ''one-pot'' extraction and chemical derivatization protocol using N-methyl-N-(tert-butyldimethylsilyl) trifluoroacetamide (MTBSTFA) and dimethylformamide (DMF) for the Sample Analysis at Mars (SAM) experiment instrument suite on NASA's the Mars Science Laboratory (MSL) mission. The temperature and duration of the derivatization reaction, pre-concentration of chemical derivatives, and gas chromatographic separation parameters have been optimized under SAM instrument design constraints. MTBSTFA/DMF extraction and derivatization at 300 1C for several minutes of a variety of terrestrial Mars analog materials facilitated the detection of amino acids and carboxylic acids in a surface soil sample collected from the Atacama Desert and a carbonate-rich stromatolite sample from Svalbard. However, the rapid reaction of MTBSTFA with water in several analog materials that contained high abundances of hydrated minerals, and the possible deactivation of derivatized compounds by iron oxides, as detected by XRD/XRF using the CheMin field unit Terra, proved to be highly problematic for the direct extraction of organics using MTBSTFA. The combination of pyrolysis and two different wet-chemical derivatization methods employed by SAM should enable a wide range of organic compounds to be detected by GCMS if present on Mars.

MSL↗

Executive summary of error sources in dynamic surface temperature measurements

Obtaining bulk T requires measuring apparent sample interface T surface , knowledge of any window conditions T window , and knowledge of thermal transport from the sample to the window. To obtain bulk T with uncertainties below 5% requires relatively small uncertainties in each of these areas, and large uncertainties in one area require smaller uncertainties in others to maintain the error budget. For example, if T window is known to 10%, a 5% total uncertainty can be obtained if T surface is known to 1% and combined transport uncertainties are known to 20%. If T surface can only be measured to 2%, combined transport uncertainties must be 17% to reach the same overall uncertainty. As the form of transport is unknown at high pressure, and window temperatures are difficult to measure by their very nature, reducing surface T uncertainties is the practical first step. Here we will discuss various error sources in the measurement of apparent T surface , and which ones must be correctly obtained prior to the experiment.

36 MATERIALS SCIENCE↗

Investigation of radiation enhanced diffusion of magnesium in substrates flown on the NASA genesis mission.

The thermal diffusion of an Mg implant in Si has been measured with SIMS and compared to RIMS (resonant ionisation mass spectrometry) measurements of Mg implantation and diffusion in Si wafers exposed to solar wind irradiation in the NASA Genesis mission. The Genesis samples show much more surface segregation that the samples annealed in the laboratory, due to diffusion and segregation of the implanted Mg to the heavily damaged near surface regions of the Genesis wafers. This Mg transport has been modeled by solving a set of stiff differential equations and found to agree with RIMS measurements for a Mg interstitial migration energy of 0.7 eV.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Process-based approach for the detection of deep gas invading the surface

The present invention includes a method for determining the level of deep gas in a near surface formation that includes: measuring CO.sub.2, O.sub.2, CH.sub.4, and N.sub.2 levels in percent by volume from one or more surface or near surface geological samples; adding the water vapor content to the measured CO.sub.2, O.sub.2, CH.sub.4, and N.sub.2 levels in percent by volume; normalizing the gas mixture to 100% by volume or 1 atmospheric total pressure; and determining the ratios of: O.sub.2 versus CO.sub.2 to distinguish in-situ vadose zone CO.sub.2 from exogenous deep leakage CO.sub.2; CO.sub.2 versus N.sub.2 to distinguish whether CO.sub.2 is being removed from the near surface formation or CO.sub.2 is added from an exogenous deep leakage input; or CO.sub.2 versus N.sub.2/O.sub.2 to determine the degree of oxygen influx, consumption, or both; wherein the ratios are indicative of natural in situ CO.sub.2 or CO.sub.2 from the exogenous deep leakage input.

47 OTHER INSTRUMENTATION↗

The Slope Imaging Multi-Polarization Photon-Counting Lidar: Development and Performance Results

The Slope Imaging Multi-polarization Photon-counting Lidar is an airborne instrument developed to demonstrate laser altimetry measurement methods that will enable more efficient observations of topography and surface properties from space. The instrument was developed through the NASA Earth Science Technology Office Instrument Incubator Program with a focus on cryosphere remote sensing. The SIMPL transmitter is an 11 KHz, 1064 nm, plane-polarized micropulse laser transmitter that is frequency doubled to 532 nm and split into four push-broom beams. The receiver employs single-photon, polarimetric ranging at 532 and 1064 nm using Single Photon Counting Modules in order to achieve simultaneous sampling of surface elevation, slope, roughness and depolarizing scattering properties, the latter used to differentiate surface types. Data acquired over ice-covered Lake Erie in February, 2009 are documenting SIMPL s measurement performance and capabilities, demonstrating differentiation of open water and several ice cover types. ICESat-2 will employ several of the technologies advanced by SIMPL, including micropulse, single photon ranging in a multi-beam, push-broom configuration operating at 532 nm.

Dabney, Phillip↗

Features of Stationary Photoconductivity of High-Ohmic Semiconductors Under Local Illumination

Photoconductivity has been thoroughly studied for a long time. However, most researchers have examined photoconductivity of semiconductors while illuminating the entire surface of samples. The present paper examines the effect of local exposure that ensures a high level of injection of free charge carriers upon the conductivity of high-ohmic cadmium telluride and semi-insulating gallium arsenide samples and upon the properties of ohmic contacts to samples. The authors found that regardless of the exposure area the value of transition resistance of ohmic contacts decreases and the concentration of the main charge carriers increases in the sample in proportion to radiation intensity. This research uncovered a number of previously unknown effects that are interesting from the physical point of view. This paper focuses on discussing these effects.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Method and apparatus for chemical and topographical microanalysis

A scanning probe microscope is combined with a laser induced breakdown spectrometer to provide spatially resolved chemical analysis of the surface correlated with the surface topography. Topographical analysis is achieved by scanning a sharp probe across the sample at constant distance from the surface. Chemical analysis is achieved by the means of laser induced breakdown spectroscopy by delivering pulsed laser radiation to the sample surface through the same sharp probe, and consequent collection and analysis of emission spectra from plasma generated on the sample by the laser radiation. The method comprises performing microtopographical analysis of the sample with a scanning probe, selecting a scanned topological site on the sample, generating a plasma plume at the selected scanned topological site, and measuring a spectrum of optical emission from the plasma at the selected scanned topological site. The apparatus comprises a scanning probe, a pulsed laser optically coupled to the probe, an optical spectrometer, and a controller coupled to the scanner, laser and spectrometer for controlling the operation of the scanner, laser and spectrometer. The probe and scanner are used for topographical profiling the sample. The probe is also used for laser radiation delivery to the sample for generating a plasma plume from the sample. Optical emission from the plasma plume is collected and delivered to the optical spectrometer so that analysis of emission spectrum by the optical spectrometer allows for identification of chemical composition of the sample at user selected sites.

Kossakovski, Dmitri A.↗

Research on lunar materials

Abstracts of 14 research reports relating to investigations of lunar samples are presented. The principal topics covered include: (1) optical properties of surface and core samples; (2) chemical composition of the surface layers of lunar grains: Auger electron spectroscopy of lunar soil and ground rock samples; (3) high frequency electrical properties of lunar soil and rock samples and their relevance for the interpretation of lunar radar observations; (4) the electrostatic dust transport process; (5) secondary electron emission characteristics of lunar soil samples and their relevance to the dust transportation process; (6) grain size distribution in surface soil and core samples; and (7) the optical and chemical effects of simulated solar wind (2keV proton and a particle radiation) on lunar material.

Gold, T.↗

Intercomparisons of GOES-derived cloud parameters and surface observations over San Nicolas Island

The spatial sampling limitations of surface measurement systems necessitate the use of satellite data for the investigation of large-scale cloud processes. Understanding the information contained in the satellite-observed radiances, however, requires a connection between the remotely sensed cloud properties and those more directly observed within the troposphere. Surface measurements taken during the First ISCCP Regional Experiment (FIRE) Marine Stratocumulus Intensive Field Observations (IFO) are compared here to cloud properties determined from Geostationary Operational Environmental Satellite (GOES) data in order to determine how well the island measurements represent larger areas and to verify some of the satellite-measured parameters.

Minnis, Patrick↗

An ultra-compact, high-throughput molecular beam epitaxy growth system

We present a miniaturized molecular beam epitaxy (miniMBE) system with an outer diameter of 206 mm, optimized for flexible and high-throughput operation. The three-chamber system, used here for oxide growth, consists of a sample loading chamber, a storage chamber, and a growth chamber. The growth chamber is equipped with eight identical effusion cell ports with linear shutters, one larger port for either a multi-pocket electron beam evaporator or an oxygen plasma source, an integrated cryoshroud, retractable beam-flux monitor or quartz-crystal microbalance, reflection high energy electron diffraction, substrate manipulator, main shutter, and quadrupole mass spectrometer. The system can be combined with ultrahigh vacuum (UHV) end stations on synchrotron and neutron beamlines, or equivalently with other complex surface analysis systems, including low-temperature scanning probe microscopy systems. Substrate handling is compatible with most UHV surface characterization systems, as the miniMBE can accommodate standard surface science sample holders. We introduce the design of the system, and its specific capabilities and operational parameters, and we demonstrate the epitaxial thin film growth of magnetoelectric Cr{sub 2}O{sub 3} on c-plane sapphire and ferrimagnetic Fe{sub 3}O{sub 4} on MgO (001)

36 MATERIALS SCIENCE↗

Design of Sample Holder for Plutonium Coupon Studies

In order to gain better understanding of the plutonium (Pu) corrosion behaviors and reaction kinetics, it is imperative that coupon experiments must be performed on well-defined surfaces. The reactions at the samples’ surfaces have to be properly monitored in terms of reactive gaseous pressures and temperatures. The pressure can be measured by using a pressure gauge, the temperature can be detected with calibrated thermal couples and/or pyrometric camera. These devices do not interfere with the chemistry of the surface reaction. However, to obtain information from the surface reaction, the aggressively machined edge and the back side of the Pu coupons need to be shielded from the applied gases. The coupons are typically made to 5/8 inch in diameter and 0.065 inch in thickness. To this end, a sample holder was designed which can seal the machined edge and the back side of coupons from the exposed gases, thus allowing proper surface reaction. The holder design was fabricated and had been tested with several coupon samples. We have achieved perfect sealing of the machined edge and the back side of the coupons, even when the coupons’ thicknesses are vastly different than the nominal thickness for which the sample holders were fabricated for. This write-up is to document the design of the holder and provide a description of the procedures to properly put the components together.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Diffusion length measurements in bulk and epitaxially grown 3-5 semiconductors using charge collection microscopy

Diffusion lengths and surface recombination velocities were measured in GaAs diodes and InP finished solar cells. The basic techniques used was charge collection microscopy also known as electron beam induced current (EBIC). The normalized currents and distances from the pn junction were read directly from the calibrated curves obtained while using the line scan mode in an SEM. These values were then equated to integral and infinite series expressions resulting from the solution of the diffusion equation with both extended generation and point generation functions. This expands previous work by examining both thin and thick samples. The surface recombination velocity was either treated as an unknown in a system of two equations, or measured directly using low e(-) beam accelerating voltages. These techniques give accurate results by accounting for the effects of surface recombination and the finite size of the generation volume.

Leon, R. P.↗

Supply Warehouse#3, SWMU 088 Operations, Maintenance, and Monitoring Report Kennedy Space Center, Florida

This document presents the findings, observations, and results associated with Operations, Maintenance, and Monitoring (OM&M) activities of Corrective Measures Implementation (CMI) activities conducted at Supply Warehouse #3 (SW3) located at John F. Kennedy Space Center (KSC), Florida from October 8, 2015, to September 12, 2016, and performance monitoring results for semi-annual sampling events conducted in March and September 2016. The primary objective of SW3 CMI is to actively decrease concentrations of trichloroethene (TCE) and vinyl chloride (VC) to less than Florida Department of Environmental Protection (FDEP) Natural Attenuation Default Concentrations (NADCs), and the secondary objective is to reduce TCE, cis-1,2-dichloroethene (cDCE), trans-1,2-dichloroethene (tDCE), 1,1-dichloroethene (11DCE), and VC concentrations to less than FDEP Groundwater Cleanup Target Levels (GCTLs). The SW3 facility has been designated Solid Waste Management Unit (SWMU) 088 under KSC's Resource Conservation and Recovery Act (RCRA) Corrective Action Program. Based on the results to date, the SW3 air sparging (AS) system is operating at or below the performance criteria as presented in the 2008 SW3 Corrective Measures Implementation (CMI) Work Plan and 2009 and 2012 CMI Work Plan Addenda. Since the start of AS system operations on December 19, 2012, through the September 2016 groundwater sampling event, TCE concentrations have decreased to less than the GCTL in all wells within the Active Remediation Zone (ARZ), and VC results remain less than NADC but greater than GCTL. Based on these results, team consensus was reached at the October 2016 KSC Remediation Team (KSCRT) meeting to continue AS system operations and semi-annual performance monitoring of volatile organic compounds in March 2017 at ten monitoring wells at select locations, and in September 2017 at four monitoring wells at select locations to reduce VC concentrations to below GCTL. Additionally, surface water samples will be collected at locations SW0001, SW0002, and SW0003 during both the March and September 2017 events. Team consensus was also reached at the October 2017 KSCRT meeting to continue with operation and maintenance (O&M) of the AS system at SW3.

REPORT↗

Crystallographic orientation of orthorhombic aragonite using reflection generalized ellipsometry

Here, the 2-modulator generalized ellipsometry microscope (2-MGEM) has been used to study a natural crystal of aragonite. Like its polymorph calcite, aragonite has a large refractive index difference between light polarized parallel to the c-axis and light polarized perpendicular to the c-axis. Unlike calcite, aragonite is orthorhombic, so there is also a very small difference between the refractive indices polarized along the a- and b-directions. As a result, it is not possible to use the 2-MGEM to obtain a definitive map of the optic axis directions of a sample as was possible with calcite, but it is possible to determine approximately the orientation of the c-axis with respect to the surface normal. If the c-axis is in the sample surface plane, it is possible to measure very small deviations of the c-axis direction with an accuracy of ~0.2°. If the c-axis is oriented normal to the sample surface, 2-MGEM data can be used to identify different crystallites due to rotations about the c-axis. For comparison, the orientations of some of the crystallites have also been measured using X-ray Laue and electron beam backscatter diffraction. In addition, spectroscopic generalized ellipsometry measurements have been used to determine the refractive indices of aragonite.

36 MATERIALS SCIENCE↗

Laser photothermal radiometric instrumentation for fast in-line industrial steel hardness inspection and case depth measurements

A contact-free, nondestructive laser photothermal radiometric instrumentation technique was developed to meet industrial demand for on-line steel hardness inspection and quality control. A series of industrial steel samples, flat or curvilinear, with different effective hardness case depths ranging between 0.21 and 1.78 mm were measured. The results demonstrated that three measurement parameters (metrics) extracted from fast swept-sine photothermal excitation and measurements, namely, the phase minimum frequency fmin, the peak or trough frequency width W, and the area S, are complementary for evaluating widely different ranges of hardness case depth: fmin is most suitable for large case depths, and W and S for small case depths. It was also found that laser beam angular inclination with respect to the surface plane of the sample strongly affects hardness measurement resolution and that the phase frequency maximum is more reliable than the amplitude maximum for laser beam focusing on the sample surface.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Diffusion length measurement in bulk and epitaxially grown III-V semiconductors using charge collection microscopy

Diffusion lengths and surface recombination velocities were measured in GaAs diodes and InP finished solar cells. The basic technique used was charge collection microscopy, also known as electron beam induced current (EBIC). The normalized currents and distances from the pn junction were read directly from the calibrated curves obtained while using the line-scan mode in an SEM. These values were then equated to integral and infinite series expressions resulting from the solution of the diffusion equation with both extended-generation and point-generation functions. This expands previous work by examining both thin and thick samples. The surface recombination velocity was either treated as an unknown in a system of two equations or measured directly using low e(-) beam accelerating voltages. These techniques give accurate results by accounting for the effects of surface recombination and the finite size of the generation volume.

Leon, R. P.↗