Search NASA⌕ Search

SEARCH · Search NASA

Results for “imaging methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

A recursive technique for adaptive vector quantization

Vector Quantization (VQ) is fast becoming an accepted, if not preferred method for image compression. The VQ performs well when compressing all types of imagery including Video, Electro-Optical (EO), Infrared (IR), Synthetic Aperture Radar (SAR), Multi-Spectral (MS), and digital map data. The only requirement is to change the codebook to switch the compressor from one image sensor to another. There are several approaches for designing codebooks for a vector quantizer. Adaptive Vector Quantization is a procedure that simultaneously designs codebooks as the data is being encoded or quantized. This is done by computing the centroid as a recursive moving average where the centroids move after every vector is encoded. When computing the centroid of a fixed set of vectors the resultant centroid is identical to the previous centroid calculation. This method of centroid calculation can be easily combined with VQ encoding techniques. The defined quantizer changes after every encoded vector by recursively updating the centroid of minimum distance which is the selected by the encoder. Since the quantizer is changing definition or states after every encoded vector, the decoder must now receive updates to the codebook. This is done as side information by multiplexing bits into the compressed source data.

Lindsay, Robert A.↗

Coronal Magnetic Field Measurement Using CME-Driven Shock Observations

Collisionless shocks form ahead of coronal mass ejections (CMEs) when the CME speed exceeds the Alfven speed of the ambient plasma in the corona and interplanetary medium. The shock stands at a distance from the CME flux rope that depends on the shock Mach number, the geometry of the driver, and the adiabatic index. While the shock ahead of the CME has been observed for a long time in the in situ data, it has been identified recently near the Sun in the coronagraphic and EUV images. Unlike in situ observations, the imaging observations are two dimensional, so one can better discern the CME-shock relationship near the Sun. Gopalswamy and Yashiro demonstrated that the coronal magnetic field can be derived from the shock standoff distance measured in coronagraphic images. The method involves measuring the standoff distance, the radius of curvature of the flux rope, and assuming the value of the adiabatic index and deriving the Alfvenic Mach number. The next step is to derive the Alfvenic Mach number from the measured shock speed and an estimate of the local solar wind speed. The final step involves deriving the magnetic field from the Alfven speed by measuring the local plasma density either from coronagraphic (polarized brightness) images or from the band-splitting of type II radio bursts. In this paper, we derive the combined magnetic field profile from near the Sun to the edge of the LASCO field of view (1.5 to 30 solar radii) and compare it with the current model profiles.

Gopalswarmy, Nat↗

Automated Inspection for Remote Telerobotic Operations

This paper reports on automated inspection techniques being researched and developed for surface inspection of remote space platforms. The unique problems of performing visual telerobotic inspection in space are identified, An image differencing method to detect changes to surfaces over a period of time is presented together with a scale-space technique for flaw identification. Examples from a laboratory mockup of space platform modules are presented to illustrate the results.

inspection↗

Improved image quality of cone beam CT scans for radiotherapy image guidance using fiber-interspaced antiscatter grid

Purpose: Medical linear accelerator mounted cone beam CT (CBCT) scanner provides useful soft tissue contrast for purposes of image guidance in radiotherapy. The presence of extensive scattered radiation has a negative effect on soft tissue visibility and uniformity of CBCT scans. Antiscatter grids (ASG) are used in the field of diagnostic radiography to mitigate the scatter. They usually do increase the contrast of the scan, but simultaneously increase the noise. Therefore, and considering other scatter mitigation mechanisms present in a CBCT scanner, the applicability of ASGs with aluminum interspacing for a wide range of imaging conditions has been inconclusive in previous studies. In recent years, grids using fiber interspacers have appeared, providing grids with higher scatter rejection while maintaining reasonable transmission of primary radiation. The purpose of this study was to evaluate the impact of one such grid on CBCT image quality. Methods: The grid used (Philips Medical Systems) had ratio of 21:1, frequency 36 lp/cm, and nominal selectivity of 11.9. It was mounted on the kV flat panel detector of an Elekta Synergy linear accelerator and tested in a phantom and a clinical study. Due to the flex of the linac and presence of gridline artifacts an angle dependent gain correction algorithm was devised to mitigate resulting artifacts. Scan reconstruction was performed using XVI4.5 augmented with inhouse developed image lag correction and Hounsfield unit calibration. To determine the necessary parameters for Hounsfield unit calibration and software scatter correction parameters, the Catphan 600 (The Phantom Laboratory) phantom was used. Image quality parameters were evaluated using CIRS CBCT Image Quality and Electron Density Phantom (CIRS) in two different geometries: one modeling head and neck and other pelvic region. Phantoms were acquired with and without the grid and reconstructed with and without software correction which was adapted for the different acquisition scenarios. Parameters used in the phantom study weret{sub cup} for nonuniformity and contrast-to-noise ratio (CNR) for soft tissue visibility. Clinical scans were evaluated in an observer study in which four experienced radiotherapy technologists rated soft tissue visibility and uniformity of scans with and without the grid. Results: The proposed angle dependent gain correction algorithm suppressed the visible ring artifacts. Grid had a beneficial impact on nonuniformity, contrast to noise ratio, and Hounsfield unit accuracy for both scanning geometries. The nonuniformity reduced by 90% for head sized object and 91% for pelvic-sized object. CNR improved compared to no corrections on average by a factor 2.8 for the head sized object, and 2.2 for the pelvic sized phantom. Grid outperformed software correction alone, but adding additional software correction to the grid was overall the best strategy. In the observer study, a significant improvement was found in both soft tissue visibility and nonuniformity of scans when grid is used. Conclusions: The evaluated fiber-interspaced grid improved the image quality of the CBCT system for broad range of imaging conditions. Clinical scans show significant improvement in soft tissue visibility and uniformity without the need to increase the imaging dose.

60 APPLIED LIFE SCIENCES↗

Phase 1 Trial of Bevacizumab With Concurrent Chemoradiation Therapy for Squamous Cell Carcinoma of the Head and Neck With Exploratory Functional Imaging of Tumor Hypoxia, Proliferation, and Perfusion

Purpose: A phase 1 trial was completed to examine the safety and feasibility of combining bevacizumab with radiation and cisplatin in patients with locoregionally advanced squamous cell carcinoma of the head and neck (HNSCC) treated with curative intent. Additionally, we assessed the capacity of bevacizumab to induce an early tumor response as measured by a series of biological imaging studies. Methods and Materials: All patients received a single induction dose of bevacizumab (15 mg/kg) delivered 3 weeks (±3 days) before the initiation of chemoradiation therapy. After the initial dose of bevacizumab, comprehensive head and neck chemoradiation therapy was delivered with curative intent to 70 Gy in 33 fractions with concurrent weekly cisplatin at 30 mg/m{sup 2} and bevacizumab every 3 weeks (weeks 1, 4, 7) with dose escalation from 5 to 10 to 15 mg/kg. All patients underwent experimental imaging with [{sup 18}F]fluorothymidine positron emission tomography (FLT-PET) (proliferation), [{sup 61}Cu]Cu-diacetyl-bis(N4-methylthiosemicarbazone) PET (Cu-ATSM-PET) (hypoxia), and dynamic contrast-enhanced computed tomography (DCE-CT) (perfusion) at 3 time points: before bevacizumab monotherapy, after bevacizumab monotherapy, and during the combined therapy course. Results: Ten patients were enrolled. All had stage IV HNSCC, all achieved a complete response to treatment, and 9 of 10 remain alive, with a mean survival time of 61.3 months. All patients experienced grade 3 toxicity, but no dose-limiting toxicities or significant bleeding episodes were observed. Significant reductions were noted in tumor proliferation (FLT-PET), tumor hypoxia (Cu-ATSM-PET), and DCE-CT contrast enhancement after bevacizumab monotherapy, with further decreases in FLT-PET and Cu-ATSM-PET during the combined therapy course. Conclusions: The incorporation of bevacizumab into comprehensive chemoradiation therapy regimens for patients with HNSCC appears safe and feasible. Experimental imaging demonstrates measureable changes in tumor proliferation, hypoxia, and perfusion after bevacizumab monotherapy and during chemoradiation therapy. These findings suggest opportunities to preview the clinical outcomes for individual patients and thereby design personalized therapy approaches in future trials.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Image Analysis for Plug Bubbles in Horizontal Flow

Horizontal plug flow is different from horizontal slug flow in that relatively few small bubbles exist in plug flow, whereas slug flow is characterized by highly aerated liquid slugs and liquid films. While the nose position and nose propagation velocity of plug bubbles may provide physical insights in understanding the flow regime transition mechanism between the plug and slug flows, few systematic investigations on these parameters have been performed in previous research. In view of this, this paper presents the development of an image processing method for the purpose of (a) obtaining data for nose position and nose propagation velocity of plug bubbles and (b) benchmarking local four-sensor conductivity probe measurements of time-averaged bubble velocity and void fraction. (authors)

42 ENGINEERING↗

Electron Tomography and Machine Learning for Understanding the Highly Ordered Structure of Leafhopper Brochosomes

Insects known as leafhoppers (Hemiptera: Cicadellidae) produce hierarchically structured nanoparticles known as brochosomes that are exuded and applied to the insect cuticle, thereby providing camouflage and anti-wetting properties to aid insect survival. Although the physical properties of brochosomes are thought to depend on the leafhopper species, the structure–function relationships governing brochosome behavior are not fully understood. Brochosomes have complex hierarchical structures and morphological heterogeneity across species, due to which a multimodal characterization approach is required to effectively elucidate their nanoscale structure and properties. In this work, we study the structural and mechanical properties of brochosomes using a combination of atomic force microscopy (AFM), electron microscopy (EM), electron tomography, and machine learning (ML)-based quantification of large and complex scanning electron microscopy (SEM) image data sets. This suite of techniques allows for the characterization of internal and external brochosome structures, and ML-based image analysis methods of large data sets reveal correlations in the structure across several leafhopper species. Our results show that brochosomes are relatively rigid hollow spheres with characteristic dimensions and morphologies that depend on leafhopper species. Nanomechanical mapping AFM is used to determine a characteristic compression modulus for brochosomes on the order of 1–3 GPa, which is consistent with crystalline proteins. Altogether, this work provides an improved understanding of the structural and mechanical properties of leafhopper brochosomes using a new set of ML-based image classification tools that can be broadly applied to nanostructured biological materials.

Chemical structure↗

Characteristic performance evaluation of a photon counting Si strip detector for low dose spectral breast CT imaging

Purpose: The possible clinical applications which can be performed using a newly developed detector depend on the detector's characteristic performance in a number of metrics including the dynamic range, resolution, uniformity, and stability. The authors have evaluated a prototype energy resolved fast photon counting x-ray detector based on a silicon (Si) strip sensor used in an edge-on geometry with an application specific integrated circuit to record the number of x-rays and their energies at high flux and fast frame rates. The investigated detector was integrated with a dedicated breast spectral computed tomography (CT) system to make use of the detector's high spatial and energy resolution and low noise performance under conditions suitable for clinical breast imaging. The aim of this article is to investigate the intrinsic characteristics of the detector, in terms of maximum output count rate, spatial and energy resolution, and noise performance of the imaging system. Methods: The maximum output count rate was obtained with a 50 W x-ray tube with a maximum continuous output of 50 kVp at 1.0 mA. A{sup 109}Cd source, with a characteristic x-ray peak at 22 keV from Ag, was used to measure the energy resolution of the detector. The axial plane modulation transfer function (MTF) was measured using a 67 μm diameter tungsten wire. The two-dimensional (2D) noise power spectrum (NPS) was measured using flat field images and noise equivalent quanta (NEQ) were calculated using the MTF and NPS results. The image quality parameters were studied as a function of various radiation doses and reconstruction filters. The one-dimensional (1D) NPS was used to investigate the effect of electronic noise elimination by varying the minimum energy threshold. Results: A maximum output count rate of 100 million counts per second per square millimeter (cps/mm{sup 2}) has been obtained (1 million cps per 100 × 100 μm pixel). The electrical noise floor was less than 4 keV. The energy resolution measured with the 22 keV photons from a {sup 109}Cd source was less than 9%. A reduction of image noise was shown in all the spatial frequencies in 1D NPS as a result of the elimination of the electronic noise. The spatial resolution was measured just above 5 line pairs per mm (lp/mm) where 10% of MTF corresponded to 5.4 mm{sup −1}. The 2D NPS and NEQ shows a low noise floor and a linear dependence on dose. The reconstruction filter choice affected both of the MTF and NPS results, but had a weak effect on the NEQ. Conclusions: The prototype energy resolved photon counting Si strip detector can offer superior imaging performance for dedicated breast CT as compared to a conventional energy-integrating detector due to its high output count rate, high spatial and energy resolution, and low noise characteristics, which are essential characteristics for spectral breast CT imaging.

60 APPLIED LIFE SCIENCES↗

A method for transferring NASTRAN data between dissimilar computers

The NASTRAN computer program is capable of executing on three different types of computers: (1) the CDC 6000 series, (2) the IBM 360-370 series, and (3) the Univac 1100 series. A typical activity requiring transfer of data between dissimilar computers is the analysis of a large structure such as the space shuttle by substructuring. Models of portions of the vehicle which have been analyzed by subcontractors using their computers must be integrated into a model of the complete structure by the prime contractor on his computer. Presently the transfer of NASTRAN matrices or tables between two different types of computers is accomplished by punched cards or a magnetic tape containing card images. These methods of data transfer do not satisfy the requirements for intercomputer data transfer associated with a substructuring activity. To provide a more satisfactory transfer of data, two new programs, RDUSER and WRTUSER, were created.

Rogers, J. L., Jr.↗

Image data compression having minimum perceptual error

A method for performing image compression that eliminates redundant and invisible image components is described. The image compression uses a Discrete Cosine Transform (DCT) and each DCT coefficient yielded by the transform is quantized by an entry in a quantization matrix which determines the perceived image quality and the bit rate of the image being compressed. The present invention adapts or customizes the quantization matrix to the image being compressed. The quantization matrix comprises visual masking by luminance and contrast techniques and by an error pooling technique all resulting in a minimum perceptual error for any given bit rate, or minimum bit rate for a given perceptual error.

Watson, Andrew B.↗

Homography generation for image registration in inlier-poor domains

A method for efficient image registration between two images in the presence of inlier-poor domains includes receiving a set of candidate correspondences between the two images. An approximate homography between the two images is generated based upon a first correspondence in the correspondences. The set of candidate correspondences is filtered to identify inlier correspondences based upon the approximate homography. A candidate homography is computed based upon the inlier correspondences. The candidate homography can be selected as a final homography between the two images based upon a support of the candidate homography against the set of candidate correspondences. An image registration is performed between the two images based upon the candidate homography being selected as the final homography.

Gonzales, Antonio↗

Solar mirror soiling and heliostat inspection from a mobile imaging system and mobile platform

A system or method for an imaging system is provided for inspecting a heliostat. The imaging system includes a platform and a camera mounted on the platform and a heliostat having a plurality of mirrored facets. The camera is positioned to acquire a first image that serves as a reference image and a second image that is a reflected image from at least one facet. The camera stores image data associated with the first image and the second image, and wirelessly transmits the stored image data to a computing apparatus. The computing apparatus compares the first image with the second image and determines a performance parameter associated with the heliostat.

Yellowhair, Julius↗

Ghost imaging second harmonic generation microscopy

A system and methods for ghost imaging second harmonic generation microscopy. Imaging data is collected in parallel, providing faster imagine reconstruction and enabling reconstruction in scattering environments. Ghost imaging, split light beam interacting with a target and a second light beam unimpeded and not required to pass through the same background. A second harmonic generation image is reconstructed from the detected photons.

Wiederrecht, Gary P.↗

Imaging grain microstructure in a model ceramic energy material with optically generated coherent acoustic phonons

Characterization of microstructure, chemistry and function of advanced energy materials remains a challenge for instrumentation science with tremendous opportunity for new discoveries. This active area of research is starting to make considerable strides with examples ranging from methodologies that employ bright X-rays, electron microscopy and optical spectroscopy. However, further development of instruments, capable of multimodal measurements, is necessary to fully reveal complex microstructure evolution in realistic environments and dynamical systems that are far from equilibrium. In this regard, laser-based instruments have a unique advantage as multiple measurement methodologies are easily combined into a single instrument using standard optics. A new pump-probe method that uses optically generated acoustic phonons is expanding standard optical characterization by providing depth resolved information. Here we report on a noteworthy extension of this pump-probe method to image grain microstructure in ceria. Rich information regarding the orientation of individual crystallites is obtained by monitoring acoustic phonon velocities and noting how the polarization of the probe beam influences the detected signal amplitude. When paired with other optical microscopies, this methodology will provide new perspectives for optical characterization of ceramic materials.

36 MATERIALS SCIENCE↗

SpaceNet 9—Cross-Sensor Alignment of Optical and SAR Imagery

Precise registration of high-resolution synthetic aperture radar (SAR) and optical imagery is necessary for realizing the full potential and benefits of multimodal image analysis. However, two significant challenges presently exist. First, there is a lack of annotated datasets and benchmarks available for high-resolution SAR–optical image registration. Second, an assessment of efficient and reliable image registration methods that can precisely align these modalities is lacking. Here, we present a holistic description of the SpaceNet 9 Challenge and its results. We present a description of the dataset and baseline algorithm along with the results of the challenge, including a description of the winning algorithms. We release the SpaceNet 9 dataset along with open-sourcing the winning algorithms and baseline. The objective of SpaceNet 9 was to compute a dense displacement map that indicates the shift needed to align pixels in an optical image to the pixels in a SAR image. The challenge launched in April 2025 and was active for approximately two months. The top five solutions reduced image alignment error from approximately 34 m to under 13 m for public and private test data, with the best results obtaining a registration error of only 8.5 and 6.7 m on the public testing and private testing dataset, respectively. Usage of pretrained image matching models, robust outlier rejection with RANSAC, and estimating local displacement were common among the top solutions. The results of this challenge provide insight into high-resolution SAR–optical image registration and offer opportunities for future benchmarking in this domain. The baseline algorithm, winning solutions, and datasets are available at https://spacenet.ai/sn9-challenge/.

benchmark datasets↗

Assessing the Need for Preprocedural Laboratory Tests and Stopping Non-steroidal Anti-inflammatory Drugs/Aspirin in Patients Undergoing Percutaneous Bone and Soft Tissue Biopsies

Purpose: Although image-guided biopsies of bone and soft tissue lesions have a low complication rate, there is limited data evaluating use of preprocedural laboratory tests. To address this issue, patients were not required to stop non-steroidal antiinflammatory drugs (NSAIDs) and aspirin or to obtain preprocedural laboratory tests [complete blood count (CBC) and international normalized ratio (INR)], except in special circumstances. The bleeding complication rate, rate of same day biopsies, and the time from when the biopsy was ordered to when it was performed were obtained. Materials and Methods: A total of 332 patients who underwent bone or soft tissue biopsies performed at our institution between 9/1/2017 and 1/9/2019 were prospectively analyzed. These data were compared to a retrospective biopsy cohort of 323 patients between 7/1/2015 and 7/1/2017. Data collected included method of image guidance and bleeding complication rate. The number of days from ordering to performing a biopsy and number of same day biopsies were recorded. Results: There were no bleeding complications in either cohort (OR 1.00, P = 1). The mean time from ordering to performing a bone biopsy was significantly decreased in the prospective group (6.6 days) compared to the retrospective group (8.1 days) (P = 0.012). There were more same day biopsies in the prospective cohort (11.4% vs. 3.4%) (P < 0.001). Conclusions: Preprocedural CBC and INR for bone and soft tissue biopsies can be safely eliminated in most patients. Biopsies performed while patients are taking NSAIDs/aspirin can safely be performed. Adopting revised preprocedural laboratory criteria can result in decreased time to completion of biopsies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Co-orchestration of multiple instruments to uncover structure–property relationships in combinatorial libraries

The rapid growth of automated and autonomous instrumentation brings forth opportunities for the co-orchestration of multimodal tools that are equipped with multiple sequential detection methods or several characterization techniques to explore identical samples. This is exemplified by combinatorial libraries that can be explored in multiple locations via multiple tools simultaneously or downstream characterization in automated synthesis systems. In co-orchestration approaches, information gained in one modality should accelerate the discovery of other modalities. Correspondingly, an orchestrating agent should select the measurement modality based on the anticipated knowledge gain and measurement cost. Herein, we propose and implement a co-orchestration approach for conducting measurements with complex observables, such as spectra or images. The method relies on combining dimensionality reduction by variational autoencoders with representation learning for control over the latent space structure and integration into an iterative workflow via multi-task Gaussian Processes (GPs). This approach further allows for the native incorporation of the system's physics via a probabilistic model as a mean function of the GPs. We illustrate this method for different modes of piezoresponse force microscopy and micro-Raman spectroscopy on a combinatorial Sm-BiFeO3 library. However, the proposed framework is general and can be extended to multiple measurement modalities and arbitrary dimensionality of the measured signals.

47 OTHER INSTRUMENTATION↗

PSF–NET: A Nonparametric Point-spread Function Model for Ground-based Optical Telescopes

Ground-based optical telescopes are seriously affected by atmospheric turbulence induced aberrations. Understanding properties of these aberrations is important both for instrument design and image restoration method development. Because the point-spread function can reflect performance of the whole optic system, it is appropriate to use the point-spread function to describe atmospheric turbulence induced aberrations. Assuming point-spread functions induced by the atmospheric turbulence with the same profile belong to the same manifold space, we propose a nonparametric point-spread function—PSF–NET. The PSF–NET has a cycle convolutional neural network structure and is a statistical representation of the manifold space of PSFs induced by the atmospheric turbulence with the same profile. Testing the PSF–NET with simulated and real observation data, we find that a well trained PSF–NET can restore any short exposure images blurred by atmospheric turbulence with the same profile. Besides, we further use the impulse response of the PSF–NET, which can be viewed as the statistical mean PSF, to analyze interpretation properties of the PSF–NET. We find that variations of statistical mean PSFs are caused by variations of the atmospheric turbulence profile: as the difference of the atmospheric turbulence profile increases, the difference between statistical mean PSFs also increases. The PSF–NET proposed in this paper provides a new way to analyze atmospheric turbulence induced aberrations, which would benefit the development of new observation methods for ground-based optical telescopes.

79 ASTRONOMY AND ASTROPHYSICS↗