Search NASA⌕ Search

SEARCH · Search NASA

Results for “CONVENTIONAL RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Microelectromechanical Systems (MEMS) Actuator for Reconfigurable Patch Antenna Demonstrated

A microstrip patch antenna with two contact actuators along the radiating edges for frequency reconfiguration was demonstrated at K-band frequencies. The layout of the antenna is shown in the following figure. This antenna has the following advantages over conventional semiconductor varactor-diode-tuned patch antennas: 1. By eliminating the semiconductor diode and its nonlinear I-V characteristics, the antenna minimizes intermodulation signal distortion. This is particularly important in digital wireless systems, which are sensitive to intersymbol interference caused by intermodulation products. 2. Because the MEMS actuator is an electrostatic device, it does not draw any current during operation and, hence, requires a negligible amount of power for actuation. This is an important advantage for hand-held, battery-operated, portable wireless systems since the battery does not need to be charged frequently. 3. The MEMS actuator does not require any special epitaxial layers as in the case of diodes and, hence, is cost effective.

Simons, Rainee N.↗

Bayesian Monte Carlo Evaluation Framework for Imperfect Data and Models [Abstract]

Nuclear data evaluation methods conventionally make the following assumptions: prior and posterior probability distribution functions (PDFs) of all model parameters and data are normal (Gaussian); the linear approximation is sufficiently accurate for minimization of a cost function (even for non-linear models); and that both the model (of, e.g., neutron cross section) and experimental data (including their covariance data) are perfect. These assumptions are inherent to the well-known generalized linear least squares (GLLS) minimization method commonly used for evaluations of resolved resonance region (RRR) neutron cross sections. However, these assumptions are often not justified due to the presence of non-normal PDFs, non-linear models (e.g. R -matrix formalism), and inherent imperfections in data and models (e.g. discrepant data sets, discrepancies between the previous evaluation and newly measured data, or imperfect covariance data). We remove the said assumptions in a mathematical framework of Bayes’ theorem, and implement it using the Metropolis-Hastings Monte Carlo method. Parameters of a new kind are introduced to parameterize inherent imperfections, e.g. , any discrepancies between the theoretical model and measured data. These new parameters enable evaluators to quantify their expert judgement about any discrepancies or imperfections in a reproducible manner. We demonstrate the framework with an ongoing evaluation of 233 U in the eV region using the ENDF-B/VIII library and transmission data measured by Guber, et al. , and compare the posterior parameters to those obtained by conventional evaluation methods.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Applications of Nuclear Physics Accelerators for Photon Science

Synchrotron radiation has been extensively developed as a source of high brightness light for materials science, chemistry and biology. Gains in brightness of 12 orders of magnitude have been achieved over conventional x-ray tubes. Now a new evolution is being enabled using superconducting linear accelerators to produce coherent light with a brightness another 8 orders of magnitude higher still. We will review the prospects of this development for photon science.

Williams, Gwyn↗

Chamonium Spectroscopy at BaBar

The charmonium-like states, Y(4260), Y(4350), produced via initial state radiation, as well as the X(3872), and Y(3940), produced in B meson decays from the BABAR B-factory are reviewed. These mesons do not seem consistent with conventional charmonium models, and several alternate hypotheses have been proposed to explain these new discoveries.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Internal Radiation Dose Evaluation For An Unruptured Post Release Tristructural Istropic Fuel Particle for Advanced and Micro-reactor Applications

There are unique benefits from advanced/micro reactor designs and fuel types that offer safety features in the case of an accident that may reduce environmental consequences compared to conventional reactors and fuels. Several micro reactor designs, for both civilian and military applications, are proposed using tristructural-isotropic (TRISO) fuel. TRISO particles are a robust advanced nuclear fuel type that leads to the unique question of how unruptured, activated TRISO particles will interact with humans. Human exposure to nuclear fuel, or radionuclides, includes all pathways of exposure. However, TRISO particles are 0.9 mm in size, and that particle size restricts internal dose assessment to the ingestion pathway; eliminating the inhalation and dermal absorption pathways. Furthermore, activity of the TRISO particle was established by High Temperature Engineering Test Reactor simulations assuming the TRISO particle was one day post-release from the reactor. International Commission of Radiological Protection publications 100 and 133 were used to develop the internal dosimetry model for an unruptured TRISO particle for the International Commission of Radiological Protection reference male and female dose assessment. The rectosigmoid colon had the highest internal organ dose for both reference male (2.1 Sv) and reference female (2.3 Sv). The internal dose from ingestion of the scenario-defined TRISO particle was 0.25 Sv for the reference male and 0.29 Sv for the refence female, which exceeds the annual occupational effective dose limit of 0.05 Sv in the code of federal regulations, 10.CFR.20 Subpart C.

61 RADIATION PROTECTION AND DOSIMETRY↗

Synchrotron Radiation for Biomedical Imaging

A synchrotron radiation (SR) X-ray source is an extraordinary tool for many applications because of the high intensity, the energy spectrum properties, the peculiar laminar beam geometry and the high degree of coherence. In the past years several experimental studies have proven the suitability of SR in the field of biomedical X-ray imaging and in diagnostic radiography. SR based X-ray imaging techniques to be mentioned are transvenous coronary angiography, bronchography, computed tomography and mammography that have been successfully implemented at different SR laboratories all around the world. Moreover, the high degree of the coherence of the synchrotron source allows the implementation of novel phase-sensitive X-ray imaging modalities. In contrast to conventional X-ray radiography, based on different X-ray absorption properties of details within an object, these phase-based techniques are capable of visualizing structures that have different scattering and refraction properties respect to the surrounding material. Their importance in medical imaging lies in the fact that the diagnosis of several diseases requires the detection of tiny structures, that consist of light elements in a similar background, and that produce very low X-ray absorption, but considerable phase shift in the wave front propagation. Thus, phase-sensitive techniques may improve dramatically the image quality and subsequently the accuracy in diagnosis offering highly enhanced contrast with dose comparable or even lower than required by conventional radiography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Total Skin Electron Beam for Primary Cutaneous T-cell Lymphoma

Purpose: Recent trials with low-dose total skin electron beam (TSEB) therapy demonstrated encouraging results for treating primary cutaneous T-cell lymphoma (PCTCL). In this study, we assessed the feasibility of different radiation doses and estimated survival rates of different pathologic entities and stages. Methods and Materials: We retrospectively identified 45 patients with PCTCL undergoing TSEB therapy between 2000 and 2015. Clinical characteristics, treatment outcomes, and toxicity were assessed. Results: A total of 49 courses of TSEB therapy were administered to the 45 patients. There were 26 pathologically confirmed cases of mycosis fungoides (MF) lymphoma, 10 cases of Sézary syndrome (SS), and 9 non-MF/SS PCTCL patients. In the MF patients, the overall response rate (ORR) was 92% (50% complete remission [CR]), 70% ORR in SS patients (50% CR), and 89% ORR in non-MF/SS patients (78% CR). The ORR for MF/SS patients treated with conventional dose (30-36 Gy) regimens was 92% (63% CR) and 75% (25% CR) for low-dose (<30-Gy) regimens (P=.09). In MF patients, the overall survival (OS) was 77 months with conventional dose regimens versus 14 months with low-dose regimens (P=.553). In SS patients, the median OS was 48 versus 16 months (P=.219), respectively. Median event-free survival (EFS) for MF in conventional dose patients versus low-dose patients was 15 versus 8 months, respectively (P=.264) and 19 versus 3 months for SS patients (P=.457). Low-dose regimens had shorter treatment time (P=.009) and lower grade 2 adverse events (P=.043). A second TSEB course was administered in 4 MF patients with 100% ORR. There is a possible prognostic impact of supplemental/boost radiation (P<.001); adjuvant treatment (P<.001) and radiation tolerability (P=.021) were detected. Conclusions: TSEB therapy is an efficacious treatment modality in the treatment of several forms of cutaneous T-cell lymphoma. There is a nonsignificant trend to higher and longer clinical benefit for MF and SS patients receiving conventional dose. Low-dose TSEB regimens are well tolerated and achieve short-term palliation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Compact Focal Plane Assembly for Planetary Science

A compact radiometric focal plane assembly (FPA) has been designed in which the filters are individually co-registered over compact thermopile pixels. This allows for construction of an ultralightweight and compact radiometric instrument. The FPA also incorporates micromachined baffles in order to mitigate crosstalk and low-pass filter windows in order to eliminate high-frequency radiation. Compact metal mesh bandpass filters were fabricated for the far infrared (FIR) spectral range (17 to 100 microns), a game-changing technology for future planetary FIR instruments. This fabrication approach allows the dimensions of individual metal mesh filters to be tailored with better than 10- micron precision. In contrast, conventional compact filters employed in recent missions and in near-term instruments consist of large filter sheets manually cut into much smaller pieces, which is a much less precise and much more labor-intensive, expensive, and difficult process. Filter performance was validated by integrating them with thermopile arrays. Demonstration of the FPA will require the integration of two technologies. The first technology is compact, lightweight, robust against cryogenic thermal cycling, and radiation-hard micromachined bandpass filters. They consist of a copper mesh supported on a deep reactive ion-etched silicon frame. This design architecture is advantageous when constructing a lightweight and compact instrument because (1) the frame acts like a jig and facilitates filter integration with the FPA, (2) the frame can be designed so as to maximize the FPA field of view, (3) the frame can be simultaneously used as a baffle for mitigating crosstalk, and (4) micron-scale alignment features can be patterned so as to permit high-precision filter stacking and, consequently, increase the filter bandwidth and sharpen the out-of-band rolloff. The second technology consists of leveraging, from another project, compact and lightweight Bi0.87Sb0.13/Sb arrayed thermopiles. These detectors consist of 30-layer thermopiles deposited in series upon a silicon nitride membrane. At 300 K, the thermopile arrays are highly linear over many orders of magnitude of incident IR power, and have a reported specific detectivity that exceeds the requirements imposed on future mission concepts. The bandpass filter array board is integrated with a thermopile array board by mounting both boards on a machined aluminum jig.

Brown, Ari↗

Proton Therapy in Pediatric Skull Base and Cervical Canal Low-Grade Bone Malignancies

Purpose: To evaluate outcomes and tolerance of high-dose photon and proton therapy in the management of skull base and cervical canal primary bony malignancies in children. Patients and Methods: Thirty children were treated postoperatively with high-dose photon-proton (29 patients) or protons-only (1 patient) radiotherapy. Twenty-six patients had chordomas (CH), 3 had low-grade chondrosarcomas (CS), and 1 had an aggressive chondroma (AC). The mean age was 12.8 years. At the time of radiation, all but 1 patient had a gross residue. The anatomic sites affected were skull base (n 16), cervical canal (n = 1), or both (n = 13). Mean total dose was 68.4 cobalt Gray equivalents, conventionally fractionated. Results: With a mean follow-up of 26.5 months, 5 of 30 children failed locally: 5 of 5 lesions were CH, 5 of 5 patients had experienced pain at presentation (p = 0.03), and 4 of 5 had cervical extension (p = 0.07). The 5-year overall survival/progression-free survival rates for CS and CH were 100%/100% and 81%/77%, respectively. Side effects were scored according to the National Cancer Institute Common Terminology Criteria for Adverse Events v3.0. Acute toxicity ranged between 0 and 2. Late toxicity of radiotherapy was severe in 1 patient (Grade 3 auditory) and minor or mild in the rest of the population (7 patients with Grade 2 pituitary dysfunction). Conclusions: High-dose combined fractionated photon-proton therapy is well tolerated in children and allows excellent local control with minimal long-term toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stereotactic Radiosurgery: Treatment of Brain Metastasis Without Interruption of Systemic Therapy

Purpose: To evaluate the prevalence, outcomes, and toxicities of concurrent delivery of systemic therapy with stereotactic radiosurgery (SRS) for treatment of brain metastases. Methods and Materials: We conducted a retrospective review of 193 patients treated at our institution with SRS without prior whole-brain radiation therapy (WBRT) for brain metastases between 2009 and 2014. Outcome metrics included administration of concurrent systemic therapy, myelosuppression, neurotoxicity, and survival. Results: One hundred ninety-three patients with a median age of 61 years underwent a total of 291 SRS treatments. Thirty-seven percent of SRS treatments were delivered concurrently with systemic therapy, of which 46% were with conventional myelosuppressive chemotherapy, and 54% with targeted and immune therapy agents. Myelosuppression was minimal after treatment with both systemic therapy and SRS, with 14% grade 3-4 toxicity for lymphopenia and 4-9% for leukopenia, neutropenia, anemia, and thrombocytopenia. Neurotoxicity was also minimal after combined therapy, with no grade 4 and <5% grade 3 toxicity, 34% dexamethasone requirement, and 4% radiation necrosis, all similar to treatments with SRS alone. Median overall survival was similar after SRS alone (14.4 months) versus SRS with systemic therapy (12.9 months). In patients with a new diagnosis of primary cancer with brain metastasis, early treatment with concurrent systemic therapy and SRS correlated with improved survival versus SRS alone (41.6 vs 21.5 months, P<.05). Conclusions: Systemic therapy can be safely given concurrently with SRS for brain metastases: our results suggest minimal myelosuppression and neurotoxicity. Concurrent therapy is an attractive option for patients who have both intracranial and extracranial metastatic disease and may be particularly beneficial in patients with a new diagnosis of primary cancer with brain metastasis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Phase-space dynamics of runaway electrons in magnetic fields

Dynamics of runaway electrons in magnetic fields are governed by the competition of three dominant physics: parallel electric field acceleration, Coulomb collision, and synchrotron radiation. Examination of the energy and pitch-angle flows reveals that the presence of local vortex structure and global circulation is crucial to the saturation of primary runaway electrons. Models for the vortex structure, which has an O-point to X-point connection, and the bump of runaway electron distribution in energy space have been developed and compared against the simulation data. Lastly, identification of these velocity-space structures opens a new venue to re-examine the conventional understanding of runaway electron dynamics in magnetic fields.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Examining Cloud Feedback Components in the Simple Cloud-Resolving E3SM Atmosphere Model (SCREAM)

Cloud feedback remains the main source of uncertainty in climate sensitivity estimated by global climate models (GCMs), largely because subgrid cloud responses are parameterized in GCMs due to their coarse resolution. Here, this study examines cloud feedback in the global 3.25-km Simple Cloud-Resolving Energy Exascale Earth System Model (E3SM) Atmosphere Model (SCREAM 3 km) through a pair of 1-yr atmosphere-only simulations with control and +4-K sea surface temperature perturbations. SCREAM 3 km produces a positive cloud feedback that falls within but at the upper end of the range of Coupled Model Intercomparison Project phase 5 (CMIP5) and CMIP phase 6 (CMIP6) models and expert judgment. The positive cloud feedback arises from positive contributions from both high- and low-level clouds, with increases in high-cloud altitude and decreases in low-cloud amount and optical depth playing key roles. The stronger-than-CMIP-average feedback is mainly attributable to the high-cloud altitude feedback, owing to cloud tops rising nearly isothermally in SCREAM 3 km. The positive low-cloud amount feedback is weaker in SCREAM than in GCMs because estimated inversion strength (EIS) increases more dramatically with warming. A coarser 12-km resolution version of SCREAM exhibits a weaker positive cloud feedback than SCREAM 3 km, mainly because its low-cloud-radiative flux is more sensitive to EIS, leading to a stronger negative low-cloud amount feedback. With this process-level assessment of cloud feedback, this study reveals where SCREAM aligns with and diverges from conventional GCMs and expert assessment, providing insights to inform further model improvement and future expert assessment.

Cloud radiative effects↗

Accelerating reconstruction of reference digital tomosynthesis using graphics hardware

The successful implementation of digital tomosynthesis (DTS) for on-board image guided radiation therapy (IGRT) requires fast DTS image reconstruction. Both target and reference DTS image sets are required to support an image registration application for IGRT. Target images are usually DTS image sets reconstructed from on-board projections, which can be accomplished quickly using the conventional filtered backprojection algorithm. Reference images are DTS image sets reconstructed from digitally reconstructed radiographs (DRRs) previously generated from conventional planning CT data. Generating a set of DRRs from planning CT is relatively slow using the conventional ray-casting algorithm. In order to facilitate DTS reconstruction within a clinically acceptable period of time, we implemented a high performance DRR reconstruction algorithm on a graphics processing unit of commercial PC graphics hardware. The performance of this new algorithm was evaluated and compared with that which is achieved using the conventional software-based ray-casting algorithm. DTS images were reconstructed from DRRs previously generated by both hardware and software algorithms. On average, the DRR reconstruction efficiency using the hardware method is improved by a factor of 67 over the software method. The image quality of the DRRs was comparable to those generated using the software-based ray-casting algorithm. Accelerated DRR reconstruction significantly reduces the overall time required to produce a set of reference DTS images from planning CT and makes this technique clinically practical for target localization for radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The reduced detailed configuration accounting (RDCA) model for the NLTE plasma special calculations

The purpose of this work is to continue development of a model to provide a fast and accurate in-line NLTE capability for calculating plasma spectral properties in large-scale radiation-transport hydrodynamic simulations. A method has recently been developed to transform the large detailed atomic models into very small models that can be used for fast in-line calculations. The reduced model is more accurate than the average-atom models conventionally used in such simulations. In the present work, spectra calculated with the reduced model are compared to the original detailed model and the average-atom model. The spectra of iron and gold plasmas under various plasma conditions are compared.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A new hybrid-Lagrangian numerical scheme for gyrokinetic simulation of tokamak edge plasma

In order to enable kinetic simulation of non-thermal edge plasmas at a reduced computational cost, a new hybrid-Lagrangian δf scheme has been developed that utilizes the phase space grid in addition to the usual marker particles, taking advantage of the computational strengths from both sides. The new scheme splits the particle distribution function of a kinetic equation into two parts. Marker particles contain the fast space-time varying, δf, part of the distribution function and the coarse-grained phase-space grid contains the slow space-time varying part. The coarse-grained phase-space grid reduces the memory-requirement and the computing cost, while the marker particles provide scalable computing ability for the fine-grained physics. Weights of the marker particles are determined by a direct weight evolution equation instead of the differential form weight evolution equations that the conventional delta-f schemes use. The particle weight can be slowly transferred to the phase space grid, thereby reducing the growth of the particle weights. The non-Lagrangian part of the kinetic equation – e.g., collision operation, ionization, charge exchange, heat-source, radiative cooling, and others – can be operated directly on the phase space grid. Deviation of the particle distribution function on the velocity grid from a Maxwellian distribution function – driven by ionization, charge exchange and wall loss – is allowed to be arbitrarily large. The numerical scheme is implemented in the gyrokinetic particle code XGC1, which specializes in simulating the tokamak edge plasma that crosses the magnetic separatrix and is in contact with the material wall.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

New progress of high current gasdynamic ion source (invited)

The experimental and theoretical research carried out at the Institute of Applied Physics resulted in development of a new type of electron cyclotron resonance ion sources (ECRISs)—the gasdynamic ECRIS. The gasdynamic ECRIS features a confinement mechanism in a magnetic trap that is different from Geller’s ECRIS confinement, i.e., the quasi-gasdynamic one similar to that in fusion mirror traps. Experimental studies of gasdynamic ECRIS were performed at Simple Mirror Ion Source (SMIS) 37 facility. The plasma was created by 37.5 and 75 GHz gyrotron radiation with power up to 100 kW. High frequency microwaves allowed to create and sustain plasma with significant density (up to 8 × 10{sup 13} cm{sup −3}) and to maintain the main advantages of conventional ECRIS such as high ionization degree and low ion energy. Reaching such high plasma density relies on the fact that the critical density grows with the microwave frequency squared. High microwave power provided the average electron energy on a level of 50-300 eV enough for efficient ionization even at neutral gas pressure range of 10{sup −4}–10{sup −3} mbar. Gasdynamic ECRIS has demonstrated a good performance producing high current (100-300 mA) multi-charged ion beams with moderate average charge (Z = 4-5 for argon). Gasdynamic ECRIS has appeared to be especially effective in low emittance hydrogen and deuterium beams formation. Proton beams with current up to 500 emA and RMS emittance below 0.07 π ⋅ mm ⋅ mrad have been demonstrated in recent experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Self-Trapped-Exciton Radiative Recombination in β–Ga 2 O 3 : Impact of Two Concurrent Nonradiative Auger Processes

The peculiarities of radiative and nonradiative processes associated with self-trapped intrinsic eXcitons in the excited β-Ga 2 O 3 crystals are studied via time-resolved techniques of induced absorption, transient grating, and photoluminescence (PL) at room temperature. The excitation above the bandgap is produced by laser pulses with linear light polarization parallel and orthogonal in the (–201) and (001) planes. We elucidate that the nonradiative recombination rate occurring in the eXciton prevails over its radiative emission rate in a wide range of free carrier concentration composed of excited and equilibrium electrons. Hence, the nonradiative recombination has no effect on the strong anisotropy and the shape of the eXciton emission band. However, we find out that the conventional ABC model of electron effective lifetime is insufficient for explanation of the excitation dependences. Inclusion of two nonradiative Auger mechanisms in a modified ABC formula provides excellent agreement of these dependences. We conclude that the trap-assisted Auger process is in proportion to the free electron density with coefficient B = 1.1 × 10 –11 cm 3 /s and appears at low/intermediate excitation, while the triple-particle Auger process is in proportion to Δn 2 with coefficient C = 8 × 10 –30 cm 6 /s and appears at high excitation conditions. The transition between two Auger mechanisms is accompanied by a rise of the eXciton diffusivity in preferred crystallographic directions where the radiative PL intensity is maximal. The diffusion length LD in these directions can reach values ~300 nm, but, at high excitations, LD becomes limited by Auger lifetimes. These findings pave the way for the implementation of self-trapped eXcitons into specific optoelectronic devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗