Search NASA⌕ Search

SEARCH · Search NASA

Results for “CALIBRATION STANDARDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

RE-EXAMINING HIGH ABUNDANCE SLOAN DIGITAL SKY SURVEY MASS-METALLICITY OUTLIERS: HIGH N/O, EVOLVED WOLF-RAYET GALAXIES?

We present new MMT spectroscopic observations of four dwarf galaxies representative of a larger sample observed by the Sloan Digital Sky Survey and identified by Peeples et al. as low-mass, high oxygen abundance outliers from the mass-metallicity relation. Peeples showed that these four objects (with metallicity estimates of 8.5 {<=} 12 + log(O/H) {<=} 8.8) have oxygen abundance offsets of 0.4-0.6 dex from the M{sub B} luminosity-metallicity relation. Our new observations extend the wavelength coverage to include the [O II] {lambda}{lambda}3726, 3729 doublet, which adds leverage in oxygen abundance estimates and allows measurements of N/O ratios. All four spectra are low excitation, with relatively high N/O ratios (N/O {approx}> 0.10), each of which tend to bias estimates based on strong emission lines toward high oxygen abundances. These spectra all fall in a regime where the 'standard' strong-line methods for metallicity determinations are not well calibrated either empirically or by photoionization modeling. By comparing our spectra directly to photoionization models, we estimate oxygen abundances in the range of 7.9 {<=} 12 + log (O/H) {<=} 8.4, consistent with the scatter of the mass-metallicity relation. We discuss the physical nature of these galaxies that leads to their unusual spectra (and previous classification as outliers), finding their low excitation, elevated N/O, and strong Balmer absorption are consistent with the properties expected from galaxies evolving past the 'Wolf-Rayet galaxy' phase. We compare our results to the 'main' sample of Peeples and conclude that they are outliers primarily due to enrichment of nitrogen relative to oxygen and not due to unusually high oxygen abundances for their masses or luminosities.

79 ASTRONOMY AND ASTROPHYSICS↗

SNe Ia tests of quintessence tracker cosmology in an anisotropic background

We investigate the observational effects of a quintessence model in an anisotropic spacetime. The anisotropic metric is a non-rotating particular case of a generalized Gödel's metric and is classified as Bianchi III. This metric is an exact solution of the Einstein-Klein-Gordon field equations with an anisotropic scalar field ψ, which is responsible for the anisotropy of the spacetime geometry. We test the model against observations of type Ia supernovae, analyzing the SDSS dataset calibrated with the MLCS2k2 fitter, and the results are compared to standard quintessence models with Ratra-Peebles potentials. We obtain a good agreement with observations, with best values for the matter and curvature density parameters Ω{sub M} = 0.29 and Ω{sub k}= 0.01 respectively. We conclude that present SNe Ia observations cannot, alone, distinguish a possible anisotropic axis in the cosmos.

79 ASTRONOMY AND ASTROPHYSICS↗

High-throughput prediction of eucalypt lignin syringyl/guaiacyl content using multivariate analysis: A comparison between mid-infrared, near-infrared, and Raman spectroscopies for model development

Background: In order to rapidly and efficiently screen potential biofuel feedstock candidates for quintessential traits, robust high-throughput analytical techniques must be developed and honed. The traditional methods of measuring lignin syringyl/guaiacyl (S/G) ratio can be laborious, involve hazardous reagents, and/or be destructive. Vibrational spectroscopy can furnish high-throughput instrumentation without the limitations of the traditional techniques. Spectral data from mid-infrared, near-infrared, and Raman spectroscopies was combined with S/G ratios, obtained using pyrolysis molecular beam mass spectrometry, from 245 different eucalypt and Acacia trees across 17 species. Iterations of spectral processing allowed the assembly of robust predictive models using partial least squares (PLS). Results: The PLS models were rigorously evaluated using three different randomly generated calibration and validation sets for each spectral processing approach. Root mean standard errors of prediction for validation sets were lowest for models comprised of Raman (0.13 to 0.16) and mid-infrared (0.13 to 0.15) spectral data, while near-infrared spectroscopy led to more erroneous predictions (0.18 to 0.21). Correlation coefficients (r) for the validation sets followed a similar pattern: Raman (0.89 to 0.91), mid-infrared (0.87 to 0.91), and near-infrared (0.79 to 0.82). These statistics signify that Raman and mid-infrared spectroscopy led to the most accurate predictions of S/G ratio in a diverse consortium of feedstocks. Conclusion: Eucalypts present an attractive option for biofuel and biochemical production. Given the assortment of over 900 different species of Eucalyptus and Corymbia , in addition to various species of Acacia , it is necessary to isolate those possessing ideal biofuel traits. This research has demonstrated the validity of vibrational spectroscopy to efficiently partition different potential biofuel feedstocks according to lignin S/G ratio, significantly reducing experiment and analysis time and expense while providing non-destructive, accurate, global, predictive models encompassing a diverse array of feedstocks.

09 BIOMASS FUELS↗

Development of Ambient Mass Spectrometry Rapid Analysis Methods for Trace Inorganics

Ambient mass spectrometry is being investigated as a new method for rapidly characterizing trace inorganic species, including nuclear materials. SRNL is currently developing electrospray ionization (ESI) and paper spray ionization (PSI) methods for mass spectrometry for the detection of trace inorganic compounds JEOL AccuTOF™-DART ® LP 4G mass spectrometer. Sample analysis generates a complex three-dimensional data set with 10 2 -10 3 individual mass spectra spread temporally. To improve the quality and ease of data extraction from this amount of information, a simple data analysis pipeline written in R/R Studio has been improved and expanded upon. Specifically, the software now has header inputs to set base input/output filenames, isotopes of interest, and a list of concentrations analyzed on the instrument. Using list-based structures to enable batch processing of many concentrations at once, it then loads each file, extracts the relevant intensities for masses of interest from each spectrum, and iterates through each concentration to generate graphs of internal standard & analyte correlations, measured isotope ratios, and total ion chromatograms. It then filters the data to remove points at background levels or at the detector saturation limit. Using this filtered data, the pipeline re-creates the graphs to reveal high-quality information from a low-quality raw dataset. All graphs of the R software then output to PowerPoint format. Additionally, faster 3D visualization functionality was added to the pipeline for viewing the entire data file produced by the instrument as an intensity map. With these data analysis tools ready, samples of strontium nitrate/yttrium nitrate as an analyte/internal standard combination were measured on the AccuTOF. From the filtered data, calibration curves were prepared and limits of detection (LOD) of 1 ppb for ESI-MS and 20 ppb for PSI-MS were obtained. The quality available from the calibration curves and the low limits of detection demonstrate the value of the instrument/analysis pipeline system in characterizing trace inorganics.

47 OTHER INSTRUMENTATION↗

APOLLO: a facility-scale differentiable virtual accelerator for Fermilab

As the design complexity of modern accelerators grows, there is more interest in using advanced simulations that have fast execution time or yield additional insights like gradients. The FAST/IOTA facility has been working on implementing and experimentally validating an end-to-end digital twin that is both fast and gradient-aware, allowing for rapid prototyping of new software and experiments with minimal beam time costs. Our framework integrates physics and ML codes for linac and ring simulation through a set of generic interfaces between surrogate and physics-based sections. To reproduce device inputs and outputs, system state is exposed as a deterministic discrete event simulator. Because Fermilab is undergoing control system transition, both EPICS and ACNET frontends are supported. Recently, we have begun transitioning to a new community lattice standard, PALS, as well as developing standardized infrastructure for data ingest and normalization to prepare for model calibration during FAST proton injector commissioning. We discuss implementation details as well as challenges, and future plans to extend modelling to main complex proton accelerators like PIPII and Booster.

Kuklev, Nikita [Fermilab]↗

Trace gases at TRACER ANC site

Speciated volatile organic compounds (VOCs) were measured using an Ionicon PTR-TOF 8000 from 20 June to 3 July 2022 at the TRACER ancillary (TRACER ANC) site in Guy, TX. The dataset is reported at 1-min time resolution. Mixing ratios (ppb) are provided for acetone, methanol, acetaldehyde, dimethyl sulfide (DMS), furan, isoprene, methyl vinyl ketone plus methyl ethyl ketone (MVK + MEK), terpenes, xylene, and trimethylbenzene. Instrument calibrations for these species were performed weekly using a certified gas standard.

acetaldehyde↗

Calibration of radiation detectors in the ultraviolet region between 972 and 2500 A

The development of experimental setups and procedures is considered for calibrating photosensitive devices in the spectral range 1022 to 2500 A for which no direct calibration techniques exist. An indirect technique that uses a sodium salicylate detector calibrated outside this range was developed for use as a secondary standard. The primary standard was a xenon-filled ionization chamber, which is an absolute standard over the wavelength interval 972 to 1022 A. Measurements made by this method were checked at 1470 A with a xenon lamp and at 2537 A with a mercury arc lamp and a 0.5 m blaze monochromator with a grating blazed at 2000 A. The overall accuracy of the measurements was + or - 40 percent or better.

Mcclenahan, J. O.↗

Manipulator For A Vacuum Chamber

Rotary seal provides for external actuators. Positioner in vacuum employs four actuators; up/down, horizontal rotary, horizontal, and vertical rotary. External up/down and azimuthal actuators drives shaft entering vacuum chamber through sliding and rotating seal. Placement of actuator motors outside vacuum chamber reduces heat-removal load on system. Atop 2.5-cm-diameter shaft is stage supporting masses as great as 15 kg. Small motors on stage provide horizontal translation and rotation in vertical plane. Manipulator developed for calibrating plasma detectors by subjecting them to particle beams in vacuum. Standard, commercially available parts used.

Hunsaker, F.↗

Low pressure gas flow analysis through an effusive inlet using mass spectrometry

A mass spectrometric method for analyzing flow past and through an effusive inlet designed for use on the tethered satellite and other entering vehicles is discussed. Source stream concentrations of species in a gaseous mixture are determined using a calibration of measured mass spectral intensities versus source stream pressure for standard gas mixtures and pure gases. Concentrations are shown to be accurate within experimental error. Theoretical explanations for observed mass discrimination effects as they relate to the various flow situations in the effusive inlet and the experimental apparatus are discussed.

Brown, David R.↗

Airborne gamma radiation soil moisture measurements over short flight lines

Results are presented on airborne gamma radiation measurements of soil moisture condition, carried out along short flight lines as part of the First International Satellite Land Surface Climatology Project Field Experiment (FIFE). Data were collected over an area in Kansas during the summers of 1987 and 1989. The airborne surveys, together with ground measurements, provide the most comprehensive set of airborne and ground truth data available in the U.S. for calibrating and evaluating airborne gamma flight lines. Analysis showed that, using standard National Weather Service weights for the K, Tl, and Gc radiation windows, the airborne soil moisture estimates for the FIFE lines had a root mean square error of no greater than 3.0 percent soil moisture. The soil moisture estimates for sections having acquisition time of at least 15 sec were found to be reliable.

Peck, Eugene L.↗

The 8-13 micron spectra of comets and the composition of silicate grains

We have analyzed the existing spectra of seven comets which show an emission feature at 7.8-13 micrometers. Most have been converted to a common calibration, taking into account the SiO feature in late-type standard stars. The spectra are compared with spectra of the Trapezium, interplanetary dust particles (IDPs), laboratory mineral samples, and small particle emission models. The emission spectra show a variety of shapes; there is no unique 'cometary silicate'. A peak at 11.20-11.25 micrometers, indicative of small crystalline olivine particles, is seen in only three comets of this sample, P/Halley, Bradfield 1987 XXIX, and Levy 1990 XX. The widths of the emission features range from 2.6 to 4.1 micrometers (FWHM). To explain the differing widths and the broad 9.8 micrometers maximum, glassy silicate particles, including both pyroxene and olivine compositions, are the most plausible candidates. Calculations of emission models confirm that small grains of glassy silicate well mixed with carbonaceous material are plausible cometary constituents. No single class of chondritic aggregate IDPs exhibits spectra closely matching the comet spectra. A mixture of IDP spectra, particularly the glass-rich aggregates, approximately matches the spectra of comets P/Halley, Levy, and Bradfield 1987 XXIX. Yet, if comets are simply a mix of IDP types, it is puzzling that the classes of IDPs are so distinct. None of the comet spectra match the spectrum of the Trapezium. Thus, the mineralogy of the cometary silicates is not the same as that of the interstellar medium. The presence of a component of crystalline silicates in comets may be evidence of mixing between high- and low-temperature regions in the solar nebula.

Hanner, Martha S.↗

The Hubble Space Telescope Extragalactic Distance Scale Key Project. 1: The discovery of Cepheids and a new distance to M81

We report on the discovery of 30 new Cepheids in the nearby galaxy M81 based on observations using the Hubble Space Telescope (HST). The periods of these Cepheids lie in the range of 10-55 days, based on 18 independent epochs using the HST wide-band F555W filter. The HST F555W and F785LP data have been transformed to the Cousins standard V and I magnitude system using a ground-based calibration. Apparent period-luminosity relations at V and I were constructed, from which apparent distance moduli were measured with respect to assumed values of mu(sub 0) = 18.50 mag and E(B - V) = 0.10 mag for the Large Magellanic Cloud. The difference in the apparent V and I moduli yields a measure of the difference in the total mean extinction between the M81 and the LMC Cepheid samples. A low total mean extinction to the M81 sample of E(B - V) = 0.03 +/- 0.05 mag is obtained. The true distance modulus to M81 is determined to be 27.80 +/- 0.20 mag, corresponding to a distance of 3.63 +/- 0.34 Mpc. These data illustrate that with an optimal (power-law) sampling strategy, the HST provides a powerful tool for the discovery of extragalactic Cepheids and their application to the distance scale. M81 is the first calibrating galaxy in the target sample of the HST Key Project on the Extragalactic Distance Scale, the ultimate aim of which is to provide a value of the Hubble constant to 10% accuracy.

Freedman, Wendy L.↗

Solar spectral irradiance observations between 200 and 360 NM made during the Atlas 1 mission: Comparisons between the SOLSPEC, SUSIM, and SSBUV measurements

The SOLSPEC, SSBUV, and SUSIM spectrometers observed the solar spectral irradiance simultaneously during the ATLAS-1 mission flown on board the Space Shuttle in March 1992. The three instruments use different methods and means of absolute calibration and were calibrated pre- and post-flight. The three data sets are reported from 200-360 nm at 1.1 nm resolution. The method of comparing the three independent data sets will be discussed. The importance of a common precise wavelength scale will be shown when comparing the data in the wavelength region of the strong Fraunhofer lines. The consistency of the three measurements is better than 5%. The fact that the calibrations of the three instruments were based on three independent national standards ensures that the absolute solar spectral irradiance in the range of 200-360 nm is now known with an accuracy of better than 5%. The data taken from this mission are compared with solar observations from other space based missions.

Thuillier, G. O.↗

Global Precipitation Analysis Using Satellite Observations

Global precipitation analysis covering the last few decades and the impact of the new TRMM (Tropical Rainfall Measuring Mission) observations are reviewed in the context of weather and climate applications. All the data sets discussed are the result of mergers of information from multiple satellites and gauges, where available. The focus of the talk is on TRMM-based 3 hr. analyses that use TRMM to calibrate polar-orbit microwave observations from SSM/I (and other satellites) and geosynchronous IR observations and merges the various calibrated observations into a final, 3 hr. resolution map. This TRMM standard product will be available for the entire TRMM period (January 1998-present) at the end of 2002. A real-time version of this merged product is being produced and is available at 0.25 deg latitude-longitude resolution over the latitude range from 50 deg N-50 deg S. Examples will be shown, including its use in monitoring flood conditions and in relating weather-scale patterns to climate-scale patterns. The 3-hourly analysis is placed in the context of two research products of the World Climate Research Program's (WCRP/GEWEX) Global Precipitation Climatology Project (GPCP). The first is the 23 year, monthly, globally complete precipitation analysis that is used to explore global and regional variations and trends and is compared to the much shorter TRMM tropical data set. The GPCP data set shows no significant global trend in precipitation over the twenty years, unlike the positive trend in global surface temperatures over the past century. Regional trends are also analyzed. A trend pattern that is a combination of both El Nino and La Nina precipitation features is evident in the Goodyear data set. This pattern is related to an increase with time in the number of combined months of El Nino and La Nina during the 23 year period. Monthly anomalies of precipitation are related to ENSO variations with clear signals extending into middle and high latitudes of both hemispheres. Also shown is the GPCP daily, 1 deg latitude-longitude analysis, which is available from January 1997 to the present. Plans to incorporate the TRMM data and 3-hourly analysis into the GPCP products are outlined. The outcome should be an improved global analysis and climatology on monthly scales for the 23 year period and finer time scale analyses for more recent periods, including real-time 3-hourly (or finer) analyses over much of the globe.

Adler, Robert F.↗

Global Precipitation Analyses at Monthly to 3-HR Time Scales

Global precipitation analysis covering the last few decades and the impact of the new TRMM precipitation observations are discussed. The 20+ year, monthly, globally complete precipitation analysis of the World Climate Research Program's (WCRP/GEWEX) Global Precipitation Climatology Project (GPCP) is used to explore global and regional variations and trends and is compared to the much shorter TRMM(Tropica1 Rainfall Measuring Mission) tropical data set. A trend pattern that is a combination of both El Nino and La Nina precipitation features is evident in the 20-year data set. This pattern is related to an increase with time in the number of combined months of El Nino and La Nina during the 20 year period. Monthly anomalies of precipitation are related to ENSO variations with clear signals extending into middle and high latitudes of both hemispheres. The GPCP daily, 1deg latitude-longitude analysis, which is available from January 1997 to the present is described and the evolution of precipitation patterns on this time scale related to El Nino and La Nina is described. Finally, a TRMM-based 3-hr analysis is described that uses TRMM to calibrate polar-orbit microwave observations from SSM/I and geosynchronous IR observations and merges the various calibrated observations into a final, 3-hr resolution map. This TRMM standard product will soon be available for the entire TRMM period (January 1998- present). A real-time version of this merged product is being produced and is available at 0.25deg latitude-longitude resolution over the latitude range from 50degN-50degS. Images from this data set can be seen at the U.S. TRMM web site (trmm.gsfc.nasa.gov). Examples will be shown, including its use in monitoring flood conditions and relating weather-scale events to climate variations.

Adler, Robert F.↗

Global Precipitation Analyses (3-Hourly to Monthly) Using TRMM, SSM/I and other Satellite Information

Global precipitation analysis covering the last few decades and the impact of the new TRMM precipitation observations are discussed. The 20+ year, monthly, globally complete precipitation analysis of the World Climate Research Program's (WCRP/GEWEX) Global Precipitation Climatology Project (GPCP) is used to explore global and regional variations and trends and is compared to the much shorter TRMM(Tropical Rainfall Measuring Mission) tropical data set. The GPCP data set shows no significant trend in precipitation over the twenty years, unlike the positive trend in global surface temperatures over the past century. Regional trends are also analyzed. A trend pattern that is a combination of both El Nino and La Nina precipitation features is evident in the 20-year data set. This pattern is related to an increase with time in the number of combined months of El Nino and La Nina during the 20 year period. Monthly anomalies of precipitation are related to ENS0 variations with clear signals extending into middle and high latitudes of both hemispheres. The GPCP daily, 1 deg. latitude-longitude analysis, which is available from January 1997 to the present is described and the evolution of precipitation patterns on this time scale related to El Nino and La Nina is discussed. Finally, a TRMM-based 3-hr analysis is described that uses TRMM to calibrate polar-orbit microwave observations from SSM/I and geosynchronous IR observations and merges the various calibrated observations into a final, 3-hr resolution map. This TRMM standard product will be available for the entire TRMM period (January 1998-present). A real-time version of this merged product is being produced and is available at 0.25 deg. latitude-longitude resolution over the latitude range from 5O deg. N-50 deg. S. Examples are shown, including its use in monitoring flood conditions.

Adler, Robert F.↗

An Analytical Calibration Approach for the Polarimetric Airborne C Band Radiometer

Passive microwave remote sensing is sensitive to the quantity and distribution of water in soil and vegetation. During summer 2000, the Microwave Geophysics Group at the University of Michigan conducted the 7th Radiobrightness Energy Balance Experiment (REBEX-7) over a corn canopy in Michigan. Long time series of brightness temperatures, soil moisture and micrometeorology on the plot scale were taken. This paper addresses the calibration of the NASA GSFC polarimetric airborne C band microwave radiometer (ACMR) that participated in REBEX-7. Passive polarimeters are typically calibrated using an end-to-end approach based upon a standard artificial target or a well-known geophysical target. Analyzing the major internal functional subsystems offers a different perspective. The primary goal of this approach is to provide a transfer function that not only describes the system in its entirety but also accounts for the contributions of each subsystem toward the final modified Stokes parameters. This approach also serves as a realistic instrument simulator, a useful tool for future designs. The ACMR architecture can be partitioned into several functional subsystems. Each subsystem was extensively measured and the estimated parameters were imported into the overall system model. We will present the results of polarimetric antenna measurements, the instrument model as well as four Stokes observations from REBEX-7 using a first order inversion.

Pham, Hanh↗

Accurate VUV Laboratory Measurements of Fe III Transitions for Astrophysical Applications

We report preliminary measurements of Fe III spectra in the 1150 to 2500 A wavelength interval. Spectra have been recorded with an iron-neon Penning discharge lamp (PDL) between 1600 and 2500 A at Imperial College (IC) using high resolution Fourier (FT) transform spectroscopy. These FT spectrometer measurements were extended beyond 1600 A to 1150 A using high-resolution grating spectroscopy at the National Institute of Standards and Technology (NIST). These recorded spectra represent the first radiometrically calibrated measurements of a doubly-ionized iron-group element spectrum combining the techniques of vacuum ultraviolet FT and grating spectroscopy. The spectral range of the new laboratory measurements corresponds to recent HST/STIS observations of sharp-lined B stars and of Eta Carinae. The new improved atomic data can be applied to abundance studies and diagnostics of astrophysical plasmas.

Blackwell-Whitehead, R. J.↗