Search NASA⌕ Search

SEARCH · Search NASA

Results for “Filtering techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Quantitative Reflection Imaging for the Morphology and Dynamics of Live Aplysia californica Pedal Ganglion Neurons Cultured on Nanostructured Plasmonic Crystals

We describe a reflection imaging system that consists of a plasmonic crystal, a common laboratory microscope, and band-pass filters for use in the quantitative imaging and in situ monitoring of live cells and their substrate interactions. Surface plasmon resonance (SPR) provides a highly sensitive method to monitor changes in physicochemical properties occurring at metal-dielectric interfaces. Polyelectrolyte thin films deposited using the layer-by-layer (LBL) self-assembly method provide a reference system for calibrating the reflection contrast changes that occur when the polyelectrolyte film thickness changes and provide insight into the optical responses that originate from the multiple plasmonic features supported by this imaging system. Finitedifference time-domain (FDTD) simulations of the optical responses measured experimentally from the polyelectrolyte reference system are used to provide a calibration of the optical system for subsequent use in quantitative studies investigating live cell dynamics in cultures supported on a plasmonic crystal substrate. Live Aplysia californica pedal ganglion neurons cultured in artificial seawater were used as a model system through which to explore the utility of this plasmonic imaging technique. Here, the morphology of cellular peripheral structures ≲80 nm in thickness were quantitatively analyzed, and the dynamics of their trypsin-induced surface detachment were visualized. These results illustrate the capacities of this system for use in investigations of the dynamics of ultrathin cellular structures within complex bioanalytical environments.

47 OTHER INSTRUMENTATION↗

A portable fiber optic sensor for the luminescent sensing of cobalt ions using carbon dots

Cobalt is critical to energy-relevant technologies, and demand for cobalt will increase significantly with growing global adoption of renewables. However, supply chain stability is threatened by economic and geopolitical factors, incentivizing domestic cobalt production from alternative resources such as coal, coal utilization byproducts (e.g., ash, acid mine drainage) and electronic waste. Rapid, inexpensive, and portable characterization techniques are needed to reduce production costs associated with cobalt prospecting and process monitoring. Here, in this research, we develop a compact, portable fiber optic luminescent probe for cobalt using phosphorus and nitrogen co-doped carbon dots as the sensing material. The carbon dot emission overlaps well with the cobalt absorption band at ~510 nm, leading to a selective decrease in emission as a function of cobalt concentration. The system responds nearly instantly to the presence of cobalt, with detection limits of 0.7 and 3.5 ppm in water and pH 1.68 buffer, respectively, providing comparable performance to a commercial spectrometer at a significantly lower cost. Moreover, the sensor is selective for cobalt in the presence of 13 of the most common metal ions encountered in coal utilization byproducts and is responsive to cobalt when spiked into an acid mine drainage leachate sample, highlighting the sensor's potential for real-world deployment in challenging matrices. In addition, integrating the carbon dots with a filter paper substrate produced ‘test strip’ sensors that exhibited a selective and sensitive visual response to cobalt using a handheld UV lamp. Taken together, the sensing system represents a significant step forward in the development of low-cost practical sensors for high-value metals in complex streams.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optimised Post-Exposure Image Sharpening Code for L3-CCD Detectors

As light from celestial bodies traverses Earth's atmosphere, the wavefronts are distorted by atmospheric turbulence, thereby lowering the angular resolution of ground-based imaging. Rapid time-series imaging enables Post-Exposure Image Sharpening (PEIS) techniques, which employ shift-and-add frame registration to remove the tip-tilt component of the wavefront error--as well as telescope wobble, thus benefiting all observations. Further resolution gains are possible by selecting only frames with the best instantaneous seeing--a technique sometimes calling 'Lucky Imaging'. We implemented these techniques in the 1990s, with the TRIFFID imaging photon-counting camera, and its associated data reduction software. The software was originally written for time-tagged photon-list data formats, recorded by detectors such as the MAMA. This paper describes our deep re-structuring of the software to handle the 2-d FITS images produced by Low Light Level CCD (L3-CCD) cameras, which have sufficient time-series resolution (>30 Hz) for PEIS. As before, our code can perform straight frame co-addition, use composite reference stars, perform PEIS under several different algorithms to determine the tip/tilt shifts, store 'quality' and shift information for each frame, perform frame selection, and generate exposure-maps for photometric correction. In addition, new code modules apply all 'static' calibrations (bias subtraction, dark subtraction and flat-fielding) to the frames immediately prior to the other algorithms. A unique feature of our PEIS/Lucky Imaging code is the use of bidirectional wiener-filtering. Coupled with the far higher sensitivity of the L3-CCD over the previous TRIFFID detectors, much fainter reference stars and much narrower time windows can be used.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Use of d-{sup 3}He proton spectroscopy as a diagnostic of shell {rho}r in capsule implosion experiments with {approx}0.2 NIF scale high temperature Hohlraums at Omega

We present the calculations and preliminary results from experiments on the Omega laser facility using d-{sup 3}He filled plastic capsule implosions in gold Hohlraums. These experiments aim to develop a technique to measure shell {rho}r and capsule unablated mass with proton spectroscopy and will be applied to future National Ignition Facility (NIF) experiments with ignition scale capsules. The Omega Hohlraums are 1900 {mu}m lengthx1200 {mu}m diameter and have a 70% laser entrance hole. This is approximately a 0.2 NIF scale ignition Hohlraum and reaches temperatures of 265-275 eV similar to those during the peak of the NIF drive. These capsules can be used as a diagnostic of shell {rho}r, since the d-{sup 3}He gas fill produces 14.7 MeV protons in the implosion, which escape through the shell and produce a proton spectrum that depends on the integrated {rho}r of the remaining shell mass. The neutron yield, proton yield, and spectra change with capsule shell thickness as the unablated mass or remaining capsule {rho}r changes. Proton stopping models are used to infer shell unablated mass and shell {rho}r from the proton spectra measured with different filter thicknesses. The experiment is well modeled with respect to Hohlraum energetics, neutron yields, and x-ray imploded core image size, but there are discrepancies between the observed and simulated proton spectra.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a Beam Hardening Correction Method for a microCT Scanner Prototype

The radiographic projections acquired with a microCT were simulated and then corrected for beam hardening effects using the linearized signal to equivalent thickness (LSET) method. This procedure requires a calibration signal for each pixel obtained from a set of images with filters of increasing thickness. The projections are corrected by converting the signal to an equivalent thickness using interpolation over the calibration images. The method was validated using simulated projections of different phantoms. Two calibration sets were simulated using aluminum and water filters of thicknesses ranging from 0 to 5 mm and from 0 to 50 mm, respectively. A simulation of the phantoms' projections using a monoenergetic beam was also obtained to establish the relative intensity on the tomographic images when no cupping artifacts are present. Comparison between corrected and uncorrected tomographic images shows that the LSET method effectively corrects the cupping artifact. Streaking artifacts correction with the LSET method shows better results than with the traditional water correction method. Results are independent of the two calibration materials used.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-I-37: Eye Lens Dose Reduction From CT Scan Using Organ Based Tube Current Modulation

Purpose: To investigate the eye lens dose reduction by CT scan with organ based tube current modulation (OBTCM) using GPU Monte Carlo code ARCHER-CT. Methods: 36 X-ray sources and bowtie filters were placed around the patient head with the projection angle interval of 10° for one rotation of CT scan, each projection was simulated respectively. The voxel eye models with high resolution(0.1mm*0.1mm*0.1mm) were used in the simulation and different tube voltage including 80kVp, 100kVp, 120kVp and 140kVp were taken into consideration. Results: The radiation doses to the eye lens increased with the tube voltage raised from 80kVp to 140kVp, and the dose results from 0° (AP) direction are much higher than those from 180° (PA) direction for all the 4 different tube voltage investigated. This 360° projection dose characteristic enables organ based TCM, which can reduce the eye lens dose by more than 55%. Conclusion: As the eye lens belongs to superficial tissues, its radiation dose to external exposure like CT is direction sensitive, and this characteristic feature makes organ based TCM to be an effective way to reduce the eye lens dose, so more clinical use of this technique were recommended. National Nature Science Foundation of China(No.11475047)

60 APPLIED LIFE SCIENCES↗

Defect filtering for thermal expansion induced dislocations in III–V lasers on silicon

Epitaxially integrated III–V semiconductor lasers for silicon photonics have the potential to dramatically transform information networks, but currently, dislocations limit performance and reliability even in defect-tolerant InAs quantum dot (QD)-based lasers. Despite being below the critical thickness, QD layers in these devices contain previously unexplained misfit dislocations, which facilitate non-radiative recombination. We demonstrate here that these misfit dislocations form during post-growth cooldown due to the combined effects of (1) thermal-expansion mismatch between the III–V layers and silicon and (2) mechanical hardening in the active region. By incorporating an additional sub-critical thickness, indium-alloyed “misfit dislocation trapping layer,” we leverage these mechanical hardening effects to our advantage, displacing 95% of misfit dislocations from the QD layer in model structures. Unlike conventional dislocation mitigation strategies, the trapping layer reduces neither the number of threading dislocations nor the number of misfit dislocations. It simply shifts the position of misfit dislocations away from the QD layer, reducing the defects' impact on luminescence. In full lasers, adding a misfit dislocation trapping layer both above and below the QD active region displaces misfit dislocations and substantially improves performance: we measure a twofold reduction in lasing threshold currents and a greater than threefold increase in output power. Overall, our results suggest that devices employing both traditional threading dislocation reduction techniques and optimized misfit dislocation trapping layers may finally lead to fully integrated, commercially viable silicon-based photonic integrated circuits.

36 MATERIALS SCIENCE↗

Soft Landing of Bare Nanoparticles with Controlled Size, Composition, and Morphology

A kinetically-limited physical synthesis method based on magnetron sputtering and gas aggregation has been coupled with size-selection and ion soft landing to prepare bare metal nanoparticles on surfaces with controlled coverage, size, composition, and morphology. Employing atomic force microscopy (AFM) and scanning electron microscopy (SEM), it is demonstrated that the size and coverage of bare nanoparticles soft landed onto flat glassy carbon and silicon as well as stepped graphite surfaces may be controlled through size-selection with a quadrupole mass filter and the length of deposition, respectively. The bare nanoparticles are observed with AFM to bind randomly to the flat glassy carbon surface when soft landed at relatively low coverage (1012 ions). In contrast, on stepped graphite surfaces at intermediate coverage (1013 ions) the soft landed nanoparticles are shown to bind preferentially along step edges forming extended linear chains of particles. At the highest coverage (5 x 1013 ions) examined in this study the nanoparticles are demonstrated with both AFM and SEM to form a continuous film on flat glassy carbon and silicon surfaces. On a graphite surface with defects, however, it is shown with SEM that the presence of localized surface imperfections results in agglomeration of nanoparticles onto these features and the formation of neighboring depletion zones that are devoid of particles. Employing high resolution scanning transmission electron microscopy in the high angular annular dark field imaging mode (STEM-HAADF) and electron energy loss spectroscopy (EELS) it is demonstrated that the magnetron sputtering/gas aggregation synthesis technique produces single metal particles with controlled morphology as well as bimetallic alloy nanoparticles with clearly defined core-shell structure. Therefore, this kinetically-limited physical synthesis technique, when combined with ion soft landing, is a versatile complementary method for preparing a wide range of bare supported nanoparticles with selected properties that are free of the solvent, organic capping agents, and residual reactants present with nanoparticles synthesized in solution.

cluster↗

A Hubble Space Telescope survey for novae in M87 – III. Are novae good standard candles 15 d after maximum brightness?

Ten weeks of daily imaging of the giant elliptical galaxy M87 with the Hubble Space Telescope (HST) has yielded 41 nova light curves of unprecedented quality for extragalactic cataclysmic variables. We have recently used these light curves to demonstrate that the observational scatter in the so-called maximum-magnitude rate of decline (MMRD) relation for classical novae is so large as to render the nova-MMRD useless as a standard candle. Here in this paper, we demonstrate that a modified Buscombe–de Vaucouleurs hypothesis, namely that novae with decline times t2 > 10 d converge to nearly the same absolute magnitude about two weeks after maximum light in a giant elliptical galaxy, is supported by our M87 nova data. For 13 novae with daily sampled light curves, well determined times of maximum light in both the F606W and F814W filters, and decline times t 2 > 10 d we find that M87 novae display M606W,15 = -6.37 ± 0.46 and M814W,15 = -6.11 ± 0.43. If very fast novae with decline times t 2 < 10 d are excluded, the distances to novae in elliptical galaxies with stellar binary populations similar to those of M87 should be determinable with 1σ accuracies of ± 20 percent with the above calibrations.

79 ASTRONOMY AND ASTROPHYSICS↗

TU-A-9A-09: Proton Beam X-Ray Fluorescence CT

Purpose: To evaluate x-ray fluorescence computed tomography induced with proton beams (pXFCT) for imaging of gold contrast agent. Methods: Proton-induced x-ray fluorescence was studied by means of Monte Carlo (MC) simulations using TOPAS, a MC code based on GEANT4. First, proton-induced K-shell and L-shell fluorescence was studied as a function of proton beam energy and 1) depth in water and 2) size of contrast object. Second, pXFCT images of a 2-cm diameter cylindrical phantom with four 5- mm diameter contrast vials and of a 20-cm diameter phantom with 1-cm diameter vials were simulated. Contrast vials were filled with water and water solutions with 1-5% gold per weight. Proton beam energies were varied from 70-250MeV. pXFCT sinograms were generated based on the net number of gold K-shell or L-shell x-rays determined by interpolations from the neighboring 0.5keV energy bins of spectra collected with an idealized 4π detector. pXFCT images were reconstructed with filtered-back projection, and no attenuation correction was applied. Results: Proton induced x-ray fluorescence spectra showed very low background compared to x-ray induced fluorescence. Proton induced L-shell fluorescence had a higher cross-section compared to K-shell fluorescence. Excitation of L-shell fluorescence was most efficient for low-energy protons, i.e. at the Bragg peak. K-shell fluorescence increased with increasing proton beam energy and object size. The 2% and 5% gold contrast vials were accurately reconstructed in K-shell pXFCT images of both the 2-cm and 20-cm diameter phantoms. Small phantom L-shell pXFCT image required attenuation correction and had a higher sensitivity for 70MeV protons compared to 250MeV protons. With attenuation correction, L-shell pXFCT might be a feasible option for imaging of small size (∼2cm) objects. Imaging doses for all simulations were 5-30cGy. Conclusion: Proton induced x-ray fluorescence CT promises to be an alternative quantitative imaging technique to the commonly considered XFCT imaging with x-ray beams.

60 APPLIED LIFE SCIENCES↗

Electric field induced needle-pulsed arc discharge carbon nanotube production apparatus: Circuitry and mechanical design

A simple and low cost apparatus is reported to produce multiwall carbon nanotubes and carbon nano-onions by a low power short pulsed arc discharge reactor. The electric circuitry and the mechanical design details and a micro-filtering assembly are described. The pulsed-plasma is generated and applied between two graphite electrodes. The pulse width is 0.3 {mu}s. A strong dc electric field is established along side the electrodes. The repetitive discharges occur in less than 1 mm distance between a sharp tip graphite rod as anode, and a tubular graphite as cathode. A hydrocarbon vapor, as carbon source, is introduced through the graphite nozzle in the cathode assembly. The pressure of the chamber is controlled by a vacuum pump. A magnetic field, perpendicular to the plasma path, is provided. The results show that the synergetic use of a pulsed-current and a dc power supply enables us to synthesize carbon nanoparticles with short pulsed plasma. The simplicity and inexpensiveness of this plan is noticeable. Pulsed nature of plasma provides some extra degrees of freedom that make the production more controllable. Effects of some design parameters such as electric field, pulse frequency, and cathode shape are discussed. The products are examined using scanning probe microscopy techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Blast from the past: constraining progenitor models of SN 1972E

ABSTRACT We present a novel technique to study Type Ia supernovae (SNe Ia) by constraining surviving companions of historical extragalactic SN by combining archival photographic plates and Hubble Space Telescope(HST) imaging. We demonstrate this technique for Supernova 1972E, the nearest known SN Ia in 125 yr. Some models of SNe Ia describe a white dwarf with a non-degenerate companion that donates enough mass to trigger thermonuclear detonation. Hydrodynamic simulations and stellar evolution models show that these donor stars will survive the explosion, and show increased luminosity for at least a 1000 yr. Thus, late-time observations of the exact location of a supernova can constrain the presence of a surviving donor star and progenitor models. We find the explosion site of SN 1972E by analysing 17 digitized photographic plates taken with the European Southern Observatory 1-m Schmidt and 1 plate taken with the Cerro Tololo Inter-American Observatory 1.5-m telescope. Using the Gaia eDR3 catalogue to determine Supernova 1972E’s location yields: α = 13h39m52${_{.}^{\rm s}}$708 ± 0${_{.}^{\rm s}}$004 and δ = −31°40’9${_{.}^{\prime\prime}}$00 ± 0${_{.}^{\prime\prime}}$04 (ICRS). In 2005, HST/ACS imaged the host galaxy of SN 1972E with the F435W, F555W, and F814W filters covering the explosion site. The nearest detected source is offset by 3.0 times our positional precision, and is inconsistent with the colours expected of a surviving donor star. Thus, the limiting magnitude of the HST observation (F555W > 28 mag) rules out all He star companion models and the most luminous main-sequence companion model currently in the literature. The remaining main-sequence companion models could be tested with a 10 orbit HST exposure in the F606W filter.

Do, Aaron↗

Superheterodyne configuration for two-wavelength interferometry applied to absolute distance measurement

We present a new superheterodyne technique for long-distance measurements by two-wavelength interferometry (TWI). While conventional systems use two acousto-optic modulators to generate two different heterodyne frequencies, here the two frequencies result from synchronized sweeps of optical and radio frequencies. A distributed feedback laser source is injected in an intensity modulator that is driven at the half-wave voltage mode. A radio-frequency signal is applied to this intensity modulator to generate two optical sidebands around the optical carrier. This applied radio frequency consists of a digital ramp between 13 and 15 GHz, with 1 ms duration and with an accuracy of better than 1 ppm. Simultaneously, the laser source is frequency modulated by a current modulation that is synchronized on the radio-frequency ramp as well as on a triangle waveform. These two frequency-swept optical signals at the output of the modulator illuminate a Michelson interferometer and create two distinct distance-dependent heterodyne frequencies on the photodetector. The superheterodyne signal is then detected and bandpass filtered to retrieve the absolute distance measurement. Experiments between 1 and 15 m confirm the validity of this new concept, leading to a distance accuracy of {+-} 50 {mu}m for a 1 ms acquisition time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of a Particle Shadow-graph Velocimetry and Size (PSVS) System to Determine Particle Size and Density Distributions in Hanford Nuclear Tank Wastes - 12280

Accurate particle size and density distributions for nuclear tank waste materials are essential information that helps determine the engineering requirements for a host of waste management unit operations (e.g., tank mixing, pipeline transport, and filtration). The most prevalent approach for determining particle size and density distribution is highly laborious and involves identifying individual particles using scanning electron microscope/x-ray diffraction and then acquiring the density of the materials from the technical literature. Other methods simply approximate individual particle densities by assuming chemical composition, rather than obtaining actual measurements of particle density. To overcome these limitations, a Particle Shadow-graph Velocimetry and Size (PSVS) system has been designed to simultaneously obtain particle size and density distributions for a broad range of Hanford tank waste materials existing as both individual particles and agglomerates. The PSVS system uses optical hardware, a temperature-controlled settling column, and particle introduction chamber to accurately and reproducibly obtain images of settling particles. Image analysis software provides a highly accurate determination of both particle terminal velocity and equivalent spherical particle diameter. The particle density is then calculated from Newton's terminal settling theory. The PSVS system was designed to accurately image particle/agglomerate sizes between 10 and 1000 μm and particle/agglomerate densities ranging from 1.4 to 11.5 g/cm{sup 3}, where the maximum terminal velocity does not exceed 10 cm/s. Preliminary testing was completed with standard materials and results were in good agreement with terminal settling theory. Recent results of this method development are presented, as well as experimental design. The primary goal of these PSVS system tests was to obtain accurate and reproducible particle size and velocity measurements to estimate particle densities within 20 percent of direct measured density values. The average percent error observed in particle densities was 4.8, 8.2, and 25.8 percent for S1D3 (high-density soda-lime glass), S3D4 (zirconia), and S1D2 (soda-lime glass) beads, respectively. The maximum measured particle density error observed was 14.5, 21.0, and 58.4, for S1D3, S3D4, and S1D2 beads, respectively. Multiple sources of error can exist that contribute to inaccurate estimates of particle density using the PSVS approach. Two significant influences observed were thermal convective currents in the settling column fluid and non-spherical (irregular) particle shapes in the standard test materials. Experimental results using buoyant beads suggest thermal convective currents can influence the movement of settling particles as much as 4 mm/s. These thermal convective currents are clearly a significant concern for smaller and less-dense particles/agglomerates which have terminal velocities of the same magnitude. Significant effort went into the design and fabrication of a thermal control system for the PSVS settling column. However, small temperature variations (<0.3 deg. C) are difficult to prevent and measure accurately. Therefore, although designing the thermal control system was necessary, it is not considered the only solution to minimize error due to thermal convective currents. The use of small diameter (10 to 27 μm) polyethylene buoyant beads (in low concentrations) during actual settling experiments may be necessary to provide insight into particle-particle interactions and fluid velocity correction factors to account for potential influences from thermal convective currents. Future testing will incorporate the buoyant beads into the analysis technique when the suspension fluid is chemically compatible. The use of the Newton's law to calculate particle/agglomerate densities assumes spherical particle shapes. As the actual particle/agglomerates diverge from spherical, the margin of error increases. The selection of high quality (in density and shape) monodispersed particle standards was a direct attempt to reduce the uncertainties associated with non-spherical or irregular particles and to only observe the PSVS method and analysis error. While investigating the source of data scatter for the S1D3 bead (nominal 700 μm) standard, significant irregular particles where discovered. Yet, a subsequent investigation into the S3D4 bead standard was also conducted and it was determined that 60 percent of the particles had a 0.9 to 0.8 centricity, 32 percent were between 0.8 and 0.7, only 7 percent were between 1.0 and 0.9, and the remaining 1 percent of the particles had centricities between 0.7 and 0.6. Contrast this with the S1D3 bead standard, where 100 percent of particles had centricities between 0.95 and 0.98, upon applying the centricity filter. The influence of the non-spherical shape of the S3D4 bead standard is evident when comparing a 3.9 percent average density error for S1D3 glass bead standard with an 8.3 percent average density error for the S3D4 bead standard. Model corrections for non-spherical shape must be implemented to account for these measurement errors during future method validation and system performance assessments. In addition, further work is needed to resolve the higher than expected velocities for the smaller S1D2 particles. Initial measurements conducted with buoyant beads as fluid velocity tracers indicate that fluid velocities can be subtracted from the increased particle velocities to determine the particle terminal velocity, regardless of the surrounding fluid velocity. However, this approach is in its infancy and will need to be carefully and methodically validated. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Experimental investigation of the response of an amorphous silicon EPID to intensity modulated radiotherapy beams

The aim of this work was to experimentally determine the difference in response of an amorphous silicon (a-Si) electronic portal imaging device (EPID) to the open and multileaf collimator (MLC) transmitted beam components of intensity modulated radiation therapy (IMRT) beams. EPID dose response curves were measured for open and MLC transmitted (MLC{sub tr}) 10x10 cm{sup 2} beams at central axis and with off axis distance using a shifting field technique. The EPID signal was obtained by replacing the flood-field correction with a pixel sensitivity variation matrix correction. This signal, which includes energy-dependent response, was then compared to ion-chamber measurements. An EPID calibration method to remove the effect of beam energy variations on EPID response was developed for IMRT beams. This method uses the component of open and MLC{sub tr} fluence to an EPID pixel calculated from the MLC delivery file and applies separate radially dependent calibration factors for each component. The calibration procedure does not correct for scatter differences between ion chamber in water measurements and EPID response; these must be accounted for separately with a kernel-based approach or similar method. The EPID response at central axis for the open beam was found to be 1.28{+-}0.03 of the response for the MLC{sub tr} beam, with the ratio increasing to 1.39 at 12.5 cm off axis. The EPID response to MLC{sub tr} radiation did not change with off-axis distance. Filtering the beam with copper plates to reduce the beam energy difference between open and MLC{sub tr} beams was investigated; however, these were not effective at reducing EPID response differences. The change in EPID response for uniform sliding window IMRT beams with MLC{sub tr} dose components from 0.3% to 69% was predicted to within 2.3% using the separate EPID response calibration factors for each dose component. A clinical IMRT image calibrated with this method differed by nearly 30% in high MLC{sub tr} regions from an image calibrated with an open beam calibration factor only. Accounting for the difference in EPID response to open and MLC{sub tr} radiation should improve IMRT dosimetry with a-Si EPIDs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Review of even element super-heavy nuclei and search for element 120

The reaction 54Cr$ + $248Cm was investigated at the velocity filter SHIP at GSI, Darmstadt, with the intention to study production and decay properties of isotopes of element 120. Three correlated signals were measured, which occurred within a period of 279ms. The heights of the signals correspond with the expectations for a decay sequence starting with an isotope of element 120. However, a complete decay chain cannot be established, since a signal from the implantation of the evaporation residue cannot be identified unambiguously. Measured properties of the event chain are discussed in detail. The result is compared with theoretical predictions. Previously measured decay properties of even element super-heavy nuclei were compiled in order to find arguments for an assignment from the systematics of experimental data. In the course of this review, a few tentatively assigned data could be corrected. New interpretations are given for results which could not be assigned definitely in previous studies. The discussion revealed that the cross-section for production of element 120 could be high enough so that a successful experiment seems possible with presently available techniques. However, a continuation of the experiment at SHIP for a necessary confirmation of the results obtained in a relatively short irradiation of five weeks is not possible at GSI presently. Furthermore, we decided to publish the results of the measurement and of the review as they exist now. In the summary and outlook section we also present concepts for the continuation of research in the field of super-heavy nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Linear Array Ultrasonic Testing Of A Thick Concrete Specimens For Non-Destructive Evaluation

The University of Minnesota and Oak Ridge National Laboratory are collaborating on the design and construction of a concrete specimen with sufficient reinforcement density and cross-sectional size to represent a light water reactor (LWR) containment wall with various defects. The preliminary analysis of the collected data using extended synthetic aperture focussin technique (SAFT) reconstruction indicated a great potential of the ultrasound array technology for locating relatively shallow distresses. However, the resolution and reliability of the analysis is inversely proportional to the defect depth and the amount of reinforcement between the measurement point and the defect location. The objective of this round of testing is to evaluate repeatability of the obtained reconstructions from measurements with different frequencies as well as to examine the effect of the duration of the sending ultrasound signal on the resulting reconstructions. Two series of testing are performed in this study. The objective of the first series is to evaluate repeatability of the measurements and resulting reconstructed images. The measurements use three center frequencies. Five measurements are performed at each location with and without lifting the device. The analysis of the collected data suggested that a linear array ultrasound system can produce reliably repeatable reconstructions using 50 kHz signals for relatively shallow depths (less than 0.5 m). However, for reconstructions at the greater depths the use of lower frequency and/or signal filtering to reduce the effect of signal noise may be required. The objective of the second series of testing is to obtain measurements with various impulse signal durations. The entire grid on the smooth surface is tested with four different various impulse signal durations. An analysis of the resulting extended SAFT reconstructions suggested that Kirchhoff-based migration leads to easier interpreting reconstructions when shorter duration impulse is used. Longer duration impulses may provide useful information for model-based reconstructions.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Accelerating reconstruction of reference digital tomosynthesis using graphics hardware

The successful implementation of digital tomosynthesis (DTS) for on-board image guided radiation therapy (IGRT) requires fast DTS image reconstruction. Both target and reference DTS image sets are required to support an image registration application for IGRT. Target images are usually DTS image sets reconstructed from on-board projections, which can be accomplished quickly using the conventional filtered backprojection algorithm. Reference images are DTS image sets reconstructed from digitally reconstructed radiographs (DRRs) previously generated from conventional planning CT data. Generating a set of DRRs from planning CT is relatively slow using the conventional ray-casting algorithm. In order to facilitate DTS reconstruction within a clinically acceptable period of time, we implemented a high performance DRR reconstruction algorithm on a graphics processing unit of commercial PC graphics hardware. The performance of this new algorithm was evaluated and compared with that which is achieved using the conventional software-based ray-casting algorithm. DTS images were reconstructed from DRRs previously generated by both hardware and software algorithms. On average, the DRR reconstruction efficiency using the hardware method is improved by a factor of 67 over the software method. The image quality of the DRRs was comparable to those generated using the software-based ray-casting algorithm. Accelerated DRR reconstruction significantly reduces the overall time required to produce a set of reference DTS images from planning CT and makes this technique clinically practical for target localization for radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗