Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microscope and microscopy.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Developing new optical imaging techniques for single particle and molecule tracking in live cells

Differential interference contrast (DIC) microscopy is a far-field as well as wide-field optical imaging technique. Since it is non-invasive and requires no sample staining, DIC microscopy is suitable for tracking the motion of target molecules in live cells without interfering their functions. In addition, high numerical aperture objectives and condensers can be used in DIC microscopy. The depth of focus of DIC is shallow, which gives DIC much better optical sectioning ability than those of phase contrast and dark field microscopies. In this work, DIC was utilized to study dynamic biological processes including endocytosis and intracellular transport in live cells. The suitability of DIC microscopy for single particle tracking in live cells was first demonstrated by using DIC to monitor the entire endocytosis process of one mesoporous silica nanoparticle (MSN) into a live mammalian cell. By taking advantage of the optical sectioning ability of DIC, we recorded the depth profile of the MSN during the endocytosis process. The shape change around the nanoparticle due to the formation of a vesicle was also captured. DIC microscopy was further modified that the sample can be illuminated and imaged at two wavelengths simultaneously. By using the new technique, noble metal nanoparticles with different shapes and sizes were selectively imaged. Among all the examined metal nanoparticles, gold nanoparticles in rod shapes were found to be especially useful. Due to their anisotropic optical properties, gold nanorods showed as diffraction-limited spots with disproportionate bright and dark parts that are strongly dependent on their orientation in the 3D space. Gold nanorods were developed as orientation nanoprobes and were successfully used to report the self-rotation of gliding microtubules on kinesin coated substrates. Gold nanorods were further used to study the rotational motions of cargoes during the endocytosis and intracellular transport processes in live mammalian cells. New rotational information was obtained: (1) during endocytosis, cargoes lost their rotation freedom at the late stage of internalization; (2) cargoes performed train-like motion when they were transported along the microtubule network by motor proteins inside live cells; (3) During the pause stage of fast axonal transport, cargoes were still bound to the microtubule tracks by motor proteins. Total internal reflection fluorescence microscopy (TIRFM) is another non-invasive and far-field optical imaging technique. Because of its near-field illumination mechanism, TIRFM has better axial resolution than epi-fluorescence microscopy and confocal microscopy. In this work, an auto-calibrated, prism type, angle-scanning TIRFM instrument was built. The incident angle can range from subcritical angles to nearly 90°, with an angle interval less than 0.2°. The angle precision of the new instrument was demonstrated through the finding of the surface plasmon resonance (SPR) angle of metal film coated glass slide. The new instrument improved significantly the precision in determining the axial position. As a result, the best obtained axial resolution was ~ 8 nm, which is better than current existing instruments similar in function. The instrument was further modified to function as a pseudo TIRF microscope. The illumination depth can be controlled by changing the incident angle of the excitation laser beam or adjusting the horizontal position of the illumination laser spot on the prism top surface. With the new technique, i.e., variable-illumination-depth pseudo TIRF microscopy, the whole cell body from bottom to top was scanned.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nanomaterial datasets to advance tomography in scanning transmission electron microscopy

Electron tomography in materials science has flourished with the demand to characterize nanoscale materials in three dimensions (3D). Access to experimental data is vital for developing and validating reconstruction methods that improve resolution and reduce radiation dose requirements. This work presents five high-quality scanning transmission electron microscope (STEM) tomography datasets in order to address the critical need for open access data in this field. The datasets represent the current limits of experimental technique, are of high quality, and contain materials with structural complexity. Included are tomographic series of a hyperbranched Co 2 P nanocrystal, platinum nanoparticles on a carbon nanofibre imaged over the complete 180° tilt range, a platinum nanoparticle and a tungsten needle both imaged at atomic resolution by equal slope tomography, and a through-focal tilt series of PtCu nanoparticles. A volumetric reconstruction from every dataset is provided for comparison and development of post-processing and visualization techniques. Researchers interested in creating novel data processing and reconstruction algorithms will now have access to state of the art experimental test data.

36 MATERIALS SCIENCE↗

Magnetic skin layer of NiO(100) probed by polarization-dependent spectromicroscopy

Using polarization-dependent x-ray photoemission electron microscopy, we have investigated the surface effects on antiferromagnetic (AFM) domain formation. Depth-resolved information obtained from our study indicates the presence of strain-induced surface AFM domains on some of the cleaved NiO(100) crystals, which are unusually thinner than bulk AFM domain wall widths (∼150 nm). Existence of such magnetic skin layer is substantiated by exchange-coupled ferromagnetic Fe domains in Fe/NiO(100), thereby evidencing the influence of this surface AFM domains on interfacial magnetic coupling. Our observations demonstrate a depth evolution of AFM structure in presence of induced surface strain, while the surface symmetry-breaking in absence of induced strain does not modify the bulk AFM domain structure. Realization of such thin surface AFM layer will provide better microscopic understanding of the exchange bias phenomena.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Topotaxial growth of α-Fe{sub 2}O{sub 3} nanowires on iron substrate

α-Fe{sub 2}O{sub 3} (hematite) nanowires have been grown by simple thermal oxidation of iron foil at 700°C in a moist oxygen flow. It was observed that the growth of nanowires highly depends on the texture of the iron substrate, in particular the presence of [110] oriented iron grains. Cross-sectional Transmission Electron Microscopy (TEM) investigation of as-grown sample revealed that the growth of nanowires has definite orientation relation with the underlying oxide grains Fe{sub 3}O{sub 4} (magnetite) and FeO (wustite), which can be interpreted by the primary orientation relationships of topotaxial growth of iron oxides. The observation can pave the way for patterning of the nanowire growth by controlling the texture of original substrate. Samples were also characterized with Scanning Electron Microscope (SEM) and X-ray diffraction (XRD).

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Integrated nonlinear optical imaging microscope for on-axis crystal detection and centering at a synchrotron beamline

Nonlinear optical (NLO) instrumentation has been integrated with synchrotron X-ray diffraction (XRD) for combined single-platform analysis, initially targeting applications for automated crystal centering. Second-harmonic-generation microscopy and two-photon-excited ultraviolet fluorescence microscopy were evaluated for crystal detection and assessed by X-ray raster scanning. Two optical designs were constructed and characterized; one positioned downstream of the sample and one integrated into the upstream optical path of the diffractometer. Both instruments enabled protein crystal identification with integration times between 80 and 150 µs per pixel, representing a ~10 3 –10 4 -fold reduction in the per-pixel exposure time relative to X-ray raster scanning. Quantitative centering and analysis of phenylalanine hydroxylase from Chromobacterium violaceum cPAH, Trichinella spiralis deubiquitinating enzyme TsUCH37, human κ-opioid receptor complex kOR-T4L produced in lipidic cubic phase (LCP), intimin prepared in LCP, and α-cellulose samples were performed by collecting multiple NLO images. The crystalline samples were characterized by single-crystal diffraction patterns, while α-cellulose was characterized by fiber diffraction. Good agreement was observed between the sample positions identified by NLO and XRD raster measurements for all samples studied.

bio-inspired↗

Influence of the Magnetic Moment of the Probe of a Magnetic Resonance Force Microscope on the Spin-Wave Resonance Spectra

Abstract—The ferromagnetic resonance in an array of permalloy microstrips 3000 × 500 × 30 nm{sup 3} in size, which are ordered on a rectangular 3.5 × 6 μm{sup 2} lattice, is studied using magnetic resonance force microscopy with strong probe–sample interaction. This interaction induces intricate modifications of the observed spectra, which are manifested both in line splitting and in changes in shape. The dependences of the observed spectra on the sample–probe distance and the orientation of the magnetic moment of the probe are analyzed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Workflow Using a Cryogenic Coincident Fluorescence, Electron, and Ion Beam Microscope for Targeted Milling of Cells

This workflow enables lamella production targeting fluorescently labeled biological structures that are small (<1 μm in axial extent) and rare (1 copy per cell) using a cryogenic tri-coincident imaging platform. In conclusion, this platform integrates fluorescence microscopy, focused ion beam milling, and scanning electron microscopy at a single focal position and enables simultaneous fluorescence microscopy while milling.

Wang, Jue [California Institute of Technology (Cal↗

HSQ double patterning process for 12 nm resolution x-ray zone plates

Soft x-ray zone plate microscopy is a powerful nano-analytic technique used for a wide variety of scientific and technological studies. Pushing its spatial resolution to 10 nm and below is highly desired and feasible due to the short wavelength of soft x-rays. Instruments using Fresnel zone plate lenses achieve a spatial resolution approximately equal to the smallest, outer most zone width. We developed a double patterning zone plate fabrication process based on a high-resolution resist, hydrogen silsesquioxane (HSQ), to bypass the limitations of conventional single exposure fabrication to pattern density, such as finite beam size, scattering in resist and modest intrinsic resist contrast. To fabricate HSQ structures with zone widths in the order of 10 nm on gold plating base, a surface conditioning process with (3-mercaptopropyl) trimethoxysilane, 3-MPT, is used, which forms a homogeneous hydroxylation surface on gold surface and provides good anchoring for the desired HSQ structures. Using the new HSQ double patterning process, coupled with an internally developed, sub-pixel alignment algorithm, we have successfully fabricated in-house gold zone plates of 12 nm outer zones. Promising results for 10 nm zone plates have also been obtained. With the 12 nm zone plates, we have achieved a resolution of 12 nm using the full-field soft x-ray microscope, XM-1.

36 MATERIALS SCIENCE↗

Quantifying the Variation in the Number of Donors in Quantum Dots Created Using Atomic Precision Advanced Manufacturing

Atomic-precision advanced manufacturing enables unique silicon quantum electronics built on quantum dots fabricated from small numbers of phosphorus dopants. The number of dopant atoms comprising a dot plays a central role in determining the behavior of charge and spin confined to the dots and thus overall device performance. Here in this work, we use both theoretical and experimental techniques to explore the combined impact of lithographic variation and stochastic kinetics on the number of P incorporations in quantum dots made using these techniques and how this variation changes as a function of the size of the dot. Using a kinetic model of PH3 dissociation augmented with novel reaction barriers, we demonstrate that for a 2 × 3 silicon dimer window the probability that no donor incorporates goes to zero, allowing for certainty in the placement of at least one donor. However, this still comes with some uncertainty in the precise number of incorporated donors (either one or two), and this variability may still impact certain applications. We also examine the impact of the size of the initial lithographic window, finding that the incorporation fraction saturates to δ-layer-like coverage as the circumference-to-area ratio decreases. We predict that this incorporation fraction depends strongly on the dosage of the precursor and that the standard deviation of the number of incorporations scales as ~√n, as would be expected for a sequence of largely independent incorporation events. Finally, we characterize an array of 36 experimentally prepared multidonor 3 × 3 nm lithographic windows with scanning tunneling microscopy, measuring the fidelity of the lithography to the desired array and the final location of PH x fragments within these lithographic windows. We use our kinetic model to examine the expected variability due to the observed lithographic error, predicting a negligible impact on incorporation statistics. We find good agreement between our model and the inferred incorporation locations in these windows from scanning tunneling microscope measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Deep Data Analytics in Structural and Functional Imaging of Nanoscale Materials

Recent advances in scanning probe microscopy and scanning transmission electron microscopy have opened unprecedented opportunities in probing the materials structural parameters and electronic properties in real space on a picometre-scale. At the same time, the ability of modern day microscopes to quickly produce large, high-resolution datasets has created a challenge for rapid physics-guided analysis of data that typically contain several hundreds to several thousand atomic or molecular units per image. Here it is demonstrated how the advanced statistical analysis and machine learning techniques can be used for extracting relevant physical and chemical information from microscope data on multiple functional materials. Specifically, the following three case studies are discussed (i) application of a combination of convolutional neural network and Markov model for analyzing positional and orientational order in molecular self-assembly; (ii) a combination of sliding window fast Fourier transform, Pearson correlation matrix and canonical correlation analysis methods to study the relationships between lattice distortions and electron scattering patterns in graphene; (iii) application of a non-negative matrix factorization with physics-based constraints and Moran’s analysis of spatial associations to extracting electronic responses linked to different types of structural domains from multi-modal imaging datasets on iron-based superconductors. The approaches demonstrated here are universal in nature and can be applied to a variety of microscopic measurements on different materials.

Ziatdinov, Maxim↗

Synthesis and crystal structure characterization of InGaZnO{sub 4} with a new defect structure

Single crystals of InGaZnO{sub 4} were synthesized in a sealed Pt-tube at elevated temperatures under normal pressure without flux. InGaZnO{sub 4} has a trigonal crystal system (R3{sup ¯}m; No. 166) deduced from convergent beam electron diffraction (CBED). Single crystal structure refinement from XRD data at −150 °C (a=3.275(1) Å; c=25.99(1) Å; Z=3) revealed an alternate stacking of InO{sub 6/3}{sup −} and (Ga,Zn)O{sub 4/4}{sup +} layers, iso-structural to YbFe{sub 2}O{sub 4}. The cell parameters at room temperature were refined from powder X-ray diffraction data (a=3.284(3) Å and c=26.037(3) Å). The transparent crystals have a gray-bluish color and exhibit an excess of Ga expressed by the cation ratio of In:Ga:Zn=30.2(9):39(1):31(1) determined by energy dispersive X-ray spectroscopy (EDXS). While the isovalent substitution of In{sup 3+} by Ga{sup 3+} is known, an additional aliovalent substitution of Zn{sup 2+} by Ga{sup 3+} is observed. This results in the formula (In{sub 0.9}Ga{sub 0.1})Ga{sub 1.06}Zn{sub 0.91}□{sub 0.03}O{sub 4} where 3% of the cations in 4+1 coordination are vacant due to aliovalent substitution. Further evidence of that defect structure is found in the lattice parameter a which is substantially smaller than in stoichiometric InGaZnO{sub 4}, as well as in the strong absorption in the near-IR from transitions correlated with the defect structure. The bluish color of the crystals is due to an enhanced absorption in the red of the visible spectrum. For the first time, we achieved to image InGaZnO{sub 4} at atomic resolution in the electron microscope proving a perfect periodic stacking of atomic layers. - Graphical abstract: Single crystals of InGaZnO{sub 4} have been synthesized at ambient pressure and analyzed with X-ray diffraction, electron microscopy, and optical absorption. Optical band gap and optical transmission have been determined. - Highlights: • Preparation of single crystals of InGaO{sub 3}(ZnO){sub 1} at ambient pressure for the first time. • Non-stoichiometric compound (In{sub 0.9}Ga{sub 0.1})Ga{sub 1.06}Zn{sub 0.91}□{sub 0.03}O{sub 4} with defect structure, excess of Ga, depletion of Zn. • Real structure of InGaO{sub 3}(ZnO){sub 1} imaged by high resolution TEM for the first time. • Optical band gap and transmission of InGaO{sub 3}(ZnO){sub 1} single crystal.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microstructural evolution and micromechanical properties of gamma-irradiated Au ball bonds

The effect of gamma radiation on the mechanical and structural properties of gold ball bonds was investigated. Gold wires from thermosonic wire bonding were exposed to gamma rays from a Cobalt-60 source at a low dose (5 Gy). The load–depth curve of nanoindentation for the irradiated gold wire bond has an apparent staircase shape during loading compared to the as-received sample. The hardness of the specimens calculated from the nanoindentation shows an increase in value from 0.91 to 1.09 GPa for specimens after exposure. The reduced elastic modulus for irradiated specimens significantly increased as well, with values from 75.18 to 98.55 GPa. The change in intrinsic properties due to gamma radiation was investigated using dual-focused ion beam and high-resolution transmission electron microscope analysis. The dual-focused ion beam and high-resolution transmission electron microscope images confirmed the changes in grain structure and the presence of dislocations. The scanning electron microscope micrographs of focused ion beam cross sections showed that the grain structure of the gold became elongated and smaller after exposure to gamma rays. Meanwhile, high-resolution transmission electron microscopy provided evidence that gamma radiation induced dislocation of the atomic arrangement. - Highlights: • Nanoindentation technique provides a detailed characterisation of Au ball bond. • P–h curve of irradiated Au ball bond shows an apparent pop-in event. • Hardness and reduced modulus increased after exposure. • Elongated and smaller grain structure in irradiated specimens • Prevalent presence of dislocations in the atomic arrangement.

36 MATERIALS SCIENCE↗

High-speed force mapping on living cells with a small cantilever atomic force microscope

The imaging speed of the wide-spread force mapping mode for quantitative mechanical measurements on soft samples in liquid with the atomic force microscope (AFM) is limited by the bandwidth of the z-scanner and viscous drag forces on the cantilever. Here, we applied high-speed, large scan-range atomic force microscopy and small cantilevers to increase the speed of force mapping by ≈10−100 times. This allowed resolving dynamic processes on living mouse embryonic fibroblasts. Cytoskeleton reorganization during cell locomotion, growth of individual cytoskeleton fibers, cell blebbing, and the formation of endocytic pits in the cell membrane were observed. Increasing the force curve rate from 2 to 300 Hz increased the measured apparent Young's modulus of the cells by about 10 times, which facilitated force mapping measurements at high speed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tailoring spectral properties for entangled photon generation

The linear intensity scaling of entangled two-photon absorption (ETPA) offers a fundamental mechanism to enable nonlinear optical spectroscopy and microscopy under a substantially lower excitation power than is currently feasible. However, the long data acquisition time and low signal-to-noise ratio in reported ETPA-based spectroscopic and microscopic studies prevent its widespread application. To gain the full potential of this novel quantum light approach, it is essential to optimize entangled photon generation for significantly enhanced ETPA responses. Here, we report a new quantum light source by combining entangled photon generation with free-space femtosecond pump-pulse shaping. Here, through measurements of singles and coincidence counts by varying the patterns applied to a spatial light modulator to control the spectral widths of the pump pulses, we reveal strong dependence of the singles and coincidence count rates as well as their ratios on the spectral widths of pump pulses. An optimal spectral width for the highest ratios between the coincidence photon and the signal or idler photon count rates is also determined. Identification of such optimal spectral widths for entangled photon generation in the presence of postgeneration spectral selection makes this quantum light source a promising choice for ETPA-based spectroscopy and imaging.

Photon pairs & parametric down-conversion↗

Towards On-Chip Learning for Low Latency Reasoning with End-to-End Synthesis

The Software Defined Architectures (SODA) Synthesizer is an open-source compiler-based tool able to automatically generate domain-specialized systems targeting Application-Specific Integrated Circuits (ASICs) or Field Programmable Gate Arrays (FPGAs) starting from high-level programming. SODA is composed of a frontend, SODA-OPT, which leverages the multilevel intermediate representation (MLIR) framework to interface with productive programming tools (e.g., machine learning frame-works), identify kernels suitable for acceleration, and perform high-level optimizations, and of a state-of-the-art high-level synthesis backend, Bambu from the PandA framework, to generate custom accelerators. One specific application of the SODA Synthesizer is the generation of accelerators to enable ultra-low latency inference and control on autonomous systems for scientific discovery (e.g., electron microscopes, sensors in particle accelerators, etc.). This paper provides an overview of the flow in the context of the generation of accelerators for edge processing to be integrated in transmission electron microscopy (TEM) devices, focusing on use cases from precision material synthesis. We show the tool in action with an example of design space exploration for inference on reconfigurable devices with a conventional deep neural network model (LeNet). Finally, we discuss the research directions and opportunities enabled by SODA in the area of autonomous control for scientific experimental workflows.

Castellana, Vito G.↗

Activity and Stability of Nanoscale Oxygen Reduction Catalysts

Design of highly active and stable nanoscale catalysts for electro-oxidation of small organic molecules is of great importance to the development of efficient fuel cells. The amount and instability of Pt-based catalysts in the cathode limits the cost, efficiency and lifetime of proton exchange membrane fuel cells. We developed a microscopic understanding of the factors governing activity and stability in Pt and PtM alloys. Experimental efforts were focused on probing the size and shape dependence of ORR activity of Pt-based nanoparticles supported on carbon nanotubes. A microscopic understanding of the activity was achieved by correlating voltammetry and rotating ring disk electrodes to surface atomic and electronic structures, which were elucidated predominantly by high-resolution transmission electron microscopy (HRTEM), Scanning transmission electron microscopy energy dispersive X-ray Spectroscopy (STEM-EDS) and synchrotron X-ray absorption spectroscopy (XAS).

30 DIRECT ENERGY CONVERSION↗

Microscopy of Electrostatic Field Effect in Novel Quantum Materials (Final Report)

In this DOE Early Career project “Microscopy of Electrostatic Field Effect in Novel Quantum Materials”, the PI’s group explored the nanoscale electronic properties when charge carriers are electrostatically modulated in functional materials. Using a microwave impedance microscope (MIM), the team probed the spatial evolution of local conductivity in various field-effect transistors (FETs) ranging from traditional metal-oxide-semiconductor FETs, sketched oxide-interface FETs, to ferroelectric FETs and electric double-layer transistors (EDLTs). Specifically, the work has led to a deep understanding on the electrical inhomogeneity and conductive edge channels in atomically thin transition metal dichalcogenides and their heterostructures, which is of fundamental importance for their applications in electronics and photonics. The unique sub-surface imaging capability also enables the first-time report of ferroelectric field effect on Ge substrates due to the polarization switching of an epitaxial BaTiO 3 layer, as well as the visualization of sketched nanostructures in the LaAlO 3 /SrTiO 3 interface. Using a cryogenic MIM, the local channel conductance in ion-gel-gated oxide EDLTs has been successfully imaged, resolving a major challenge in the EDLT research to study electronic fluctuations in the devices. Finally, a new tuning-fork-based MIM has been developed to perform quantitative conductivity imaging on back-gated FETs. The research supported by this DOE grant is significant for understanding the nanoscale uniformity in technologically important materials towards energy applications.

2D materials↗

High-resolution magnetic microscopy applications using nitrogen-vacancy centers in diamond

Magnetic microscopy with high spatial resolution helps to solve a variety of technical problems in condensed-matter physics, electrical engineering, biomagnetism, and geomagnetism. In this work we used quantum diamond magnetic microscope (QDMM) setups, which use a dense uniform layer of magnetically-sensitive nitrogen-vacancy (NV) centers in diamond to image an external magnetic field using a fluorescence microscope. We used this technique for imaging few-micron ferromagnetic needles used as a physically unclonable function (PUF) and to passively interrogate electric current paths in a commercial 555 timer integrated circuit (IC). As part of the QDMM development, we also found a way to calculate ion implantation recipes to create diamond samples with dense uniform NV layers at the surface. This work opens the possibility for follow-up experiments with 2D magnetic materials, ion implantation, and electronics characterization and troubleshooting.

36 MATERIALS SCIENCE↗