Search NASA⌕ Search

SEARCH · Search NASA

Results for “accelerator performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Capacitance-Based Dimensional Change Sensors for In-Pile Materials Measurements

Advanced fuel compositions, such as accident tolerate fuels (ATF), are an active area of developing in the nuclear power industry. The long-term performance of these newly developed fuels is estimated through physics-based simulation models of irradiation-, temperature-, pressure-, etc.-induced material degradation. As these fuels are deployed in test reactors, measurement and characterization of the fuel pin evolution is used to validate prediction models. In-pile material evolution parameters, such as fuel rod pressurization, fuel stack and cladding elongation, and cladding diameter, are commonly measured using a linear voltage differential transformer (LVDT). However, LVDTs are bulky and limited to lower (350-500C) temperature operation. The high power density and small size of most experimental positions in high performance research reactors used for accelerated materials irradiation studies generally precludes the use of LVDTs in these reactors. There is a critical need for sensors that provide real-time data regarding material evolution under highly accelerated irradiation. These sensors would ideally have a small profile and the ability to withstand irradiation at extremely high dose rates and temperatures for extended periods of time. A capacitance-based sensor is currently under development at the University of Tennessee to provide a direct measurement of in-pile dimensional change during irradiation. Sensor response was simulated using AutoCAD Electromagnetic field simulator (EMS) for a variety of sensor materials and configurations and fuel pin swelling conditions. Initial results of these simulations are summarized and areas of ongoing research and development are discussed.

Naughton, Tyler↗

Scalable Heterogeneous Execution of a Coupled-Cluster Model with Perturbative Triples

The CCSD(T) coupled-cluster model with perturbative triples is considered a gold standard for computational modeling of the correlated behavior of electrons in molecular systems. A fundamental constraint is the relatively small global-memory capacity in GPUs compared to the main-memory capacity on host nodes, necessitating relatively smaller tile sizes for high-dimensional tensor contractions in NWChem's GPU-accelerated implementation of the CCSD(T) method. A coordinated redesign is described to address this limitation and associated data movement overheads, including a novel fused GPU kernel for a set of tensor contractions, along with inter-node communication optimization and data caching. The new implementation of GPU-accelerated CCSD(T) improves overall performance by 3.4x. Finally, we discuss the trade-offs in using this fused algorithm on current and future supercomputing platforms.

Kim, Jinsung↗

Precise measurement of the nuclear dependence of the EMC effect in light nuclei

Measurements of inclusive electron scattering cross-section ratios from light nuclei over a wide range of the Björken G (0.3 ? G ? 1) up to &2 = 8.3 GeV2 were made as part of experiment E10-10-008, which was conducted in Hall C at the Thomas Jefferson National Accelerator Facility. The measurements were performed using a beam energy of 10.602 GeV and an average beam current of 45 `A. This dissertation provides a thorough description of the experiment as well as the extracted ratios of inclusive nuclear cross-sections with respect to the deuterium cross-sections (the EMC effect) for the targets 9Be, 12C, 10B, and 11B. The nuclear dependence of the inclusive inelastic electron scattering cross-section has been measured for the first time in 10B and 11B.

Karki, Abishek↗

Development and Reliability of Screen-Printable Fire-Through Cu Paste for Passivated Contact Solar Cells

We present the development of copper (Cu) paste which has been screen printed on Selective Emitter-Passivated Emitter Rear Contact (SE-PERC) solar cells. This paste can also be applied to Tunnel Oxide Passivated Contact (TOPCON) solar cells due to its fire-through nature. Champion PERC cells have achieved ....efficiency with ...parameters . Accelerated testing to investigate reliability performance of the SE- PERC mini-modules were carried out in damp heat chamber with 85oC and 85% humidity. The devices were found to be operational even after 1,500 hours. Devices with screen printed Ag contacts on the front side have been studied in parallel to the Cu contacts for comparison.

copper paste↗

Segmented wall-less hall thruster

Disclosed is a miniaturized plasma propulsion device with minimized surface area of the thruster walls exposed to the plasma and, as a result, reduced plasma-surface interactions including a set of segmented electrodes to facilitate the following improvements compared to relevant existing technologies: 1) control of the plasma flow including focusing of the plasma plume 2) increase of the thrust 2) reduction of inefficiencies associated with the electron cross field current, and 3) mitigation of low frequency oscillations. The electrodes affect all these actions when a DC or modulated voltage is applied to one or all of them with the same or different amplitudes, with the same or different frequencies or phases which are all optimized to realize the best performance through changes in the acceleration and/or ionization regions. In addition, the applied voltage to the main electrodes may also be modulated.

Simmonds, Jacob↗

Construction, Test And Calibration of the GLAST Silicon Tracker

The Gamma-ray Large Area Space Telescope represents a great advance in space application of silicon detectors. With a surface of 80 m{sup 2} and about 1 M readout channels it is the largest silicon tracker ever built for a space experiment. GLAST is an astro-particle mission that will study the mostly unexplored, high energy (20 MeV-300 GeV) spectrum coming from active sources or diffused in the Universe. The detector integration and test phase is complete. The full instrument underwent environmental testing and the spacecraft integration phase has just started: the launch is foreseen in late 2007. In the meanwhile the spare modules are being used for instrument calibration and performance verification employing the CERN accelerator complex. A Calibration Unit has been exposed to photon, electron and hadron beams from a few GeV up to 300 GeV. We report on the status of the instrument and on the calibration campaign.

Instrumentation,OTHER↗

Preparing MPICH for exascale

The advent of exascale supercomputers heralds a new era of scientific discovery, yet it introduces significant architectural challenges that must be overcome for MPI applications to fully exploit its potential. Among these challenges is the adoption of heterogeneous architectures, particularly the integration of GPUs to accelerate computation. Additionally, the complexity of multithreaded programming models has also become a critical factor in achieving performance at scale. The efficient utilization of hardware acceleration for communication, provided by modern NICs, is also essential for achieving low latency and high throughput communication in such complex systems. In response to these challenges, the MPICH library, a high-performance and widely used Message Passing Interface (MPI) implementation, has undergone significant enhancements. Here, this paper presents four major contributions that prepare MPICH for the exascale transition. First, we describe a lightweight communication stack that leverages the advanced features of modern NICs to maximize hardware acceleration. Second, our work showcases a highly scalable multithreaded communication model that addresses the complexities of concurrent environments. Third, we introduce GPU-aware communication capabilities that optimize data movement in GPU-integrated systems. Finally, we present a new datatype engine aimed at accelerating the use of MPI derived datatypes on GPUs. These improvements in the MPICH library not only address the immediate needs of exascale computing architectures but also set a foundation for exploiting future innovations in high-performance computing. By embracing these new designs and approaches, MPICH-derived libraries from HPE Cray and Intel were able to achieve real exascale performance on OLCF Frontier and ALCF Aurora respectively.

Guo, Yanfei [Argonne National Laboratory (ANL), Ar↗

A feasibility study of using couch-based real time dosimetric device in external beam radiotherapy

Purpose: Measurement of actual dose delivered during radiotherapy treatment aids in checking the accuracy of dose delivered to the patient. In this study, a couch-based real time dosimetric device has been proposed to measure the exit or entrance dose to a patient during external beam radiotherapy. The utility and feasibility of such a device using a 2D array of diodes has been demonstrated. Methods: Two MAPCHECK devices: MAPCHECK (1175) and MAPCHECK 2 (both SunNuclear) were embedded in a foam block in the treatment couch of a Varian 21iX linear accelerator. The angular dependence of the detector response for both devices was studied before implementing the MAPCHECKs for experimental purposes. An Alderson Rando head phantom was scanned with the MAPCHECK and MAPCHECK 2 devices separately and four different treatment plans were generated with target volumes at three different positions simulating typical clinical situations. The analytical anisotropic algorithm (AAA) was used to compute the doses in an Eclipse treatment planning system (Varian Medical Systems). The Rando phantom with the MAPCHECK device was exposed in Clinac 21iX linear accelerator. The measured dose distribution was compared with the calculated dose distribution to check for the accuracy in dose delivery. Results: Measured and computed dose distribution were found to agree with more than 93% of pixels passing at 3% and 3 mm gamma criteria for all the treatment plans. The couch-based real time dosimetry system may also be applied for noncoplanar beams where electronic portal imaging device (EPID) is not practical to measure the dose. Other advantages include checking the beam stability during the patient treatment, performing routine morning quality assurance (QA) tests in the linear accelerator, and to perform pretreatment verification of intensity modulated radiation therapy (IMRT). One of the drawbacks of this system is that it cannot be used for measuring the dose at 90 deg. or 270 deg. gantry angles. Conclusions: This preliminary study shows that a 2D array of detectors may be used as part of the treatment couch for real time patient dosimetry in studying the dose delivered to the patient in real time and also for performing routine quality assurance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimal utilization of heterogeneous resources for biomolecular simulations.

Biomolecular simulations have traditionally benefited from increases in the processor clock speed and coarse-grain inter-node parallelism on large-scale clusters. With stagnating clock frequencies, the evolutionary path for performance of microprocessors is maintained by virtue of core multiplication. Graphical processing units (GPUs) offer revolutionary performance potential at the cost of increased programming complexity. Furthermore, it has been extremely challenging to effectively utilize heterogeneous resources (host processor and GPU cores) for scientific simulations, as underlying systems, programming models and tools are continually evolving. In this paper, we present a parametric study demonstrating approaches to exploit resources of heterogeneous systems to reduce time-to-solution of a production-level application for biological simulations. By overlapping and pipelining computation and communication, we observe up to 10-fold application acceleration in multi-core and multi-GPU environments illustrating significant performance improvements over code acceleration approaches, where the host-to-accelerator ratio is static, and is constrained by a given algorithmic implementation.

99 GENERAL AND MISCELLANEOUS↗

Optimal utilization of heterogeneous resources for biomolecular simulations

Biomolecular simulations have traditionally benefited from increases in the processor clock speed and coarse-grain inter-node parallelism on large-scale clusters. With stagnating clock frequencies, the evolutionary path for performance of microprocessors is maintained by virtue of core multiplication. Graphical processing units (GPUs) offer revolutionary performance potential at the cost of increased programming complexity. Furthermore, it has been extremely challenging to effectively utilize heterogeneous resources (host processor and GPU cores) for scientific simulations, as underlying systems, programming models and tools are continually evolving. In this paper, we present a parametric study demonstrating approaches to exploit resources of heterogeneous systems to reduce time-to-solution of a production-level application for biological simulations. By overlapping and pipelining computation and communication, we observe up to 10-fold application acceleration in multi-core and multi-GPU environments illustrating significant performance improvements over code acceleration approaches, where the host-to-accelerator ratio is static, and is constrained by a given algorithmic implementation.

59 BASIC BIOLOGICAL SCIENCES↗

Surface processing for bulk niobium superconducting radio frequency cavities

The majority of niobium cavities for superconducting particle accelerators continue to be fabricated from thin-walled (2-4mm) polycrystalline niobium sheet and, as a final step, require material removal from the radio frequency (RF) surface in order to achieve performance needed for use as practical accelerator devices. More recently bulk niobium in the form of, single-or large-grain slices cut from an ingot has become a viable alternative for some cavity types. In both cases the so-called damaged layer must be chemically etched or electrochemically polished away. The methods for doing this date back at least four decades, however, vigorous empirical studies on real cavities and more fundamental studies on niobium samples at laboratories worldwide have led to seemingly modest improvements that, when taken together, constitute a substantial advance in the reproducibility for surface processing techniques and overall cavity performance. This article reviews the development of niobium cavity surface processing, and summarizes results of recent studies. We place some emphasis on practical details for real cavity processing systems which are difficult to find in the literature but are, nonetheless, crucial for achieving the good and reproducible cavity performance. New approaches for bulk niobium surface treatment which aim to reduce cost or increase performance, including alternate chemical recipes, barrel polishing and 'nitrogen doping' of the RF surface, continue to be pursued and are closely linked to the requirements for surface processing.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Bridging the Gap Between Modern UX Design and Particle Accelerator Control Room Interfaces

Accelerator control systems often represent relatively complex and safety-sensitive human-machine interfaces within process control industries. These systems are technically robust and reflect the cumulative integration of solutions built and adapted across decades. One of the regular, unfortunate casualties of provisional accelerator control system updates is their human-system interfaces (HSIs) which often lag behind modern usability and design standards. An additional challenge is that although there is a multitude of established human factors (HF), and user experience (UX) principles for everyday digital applications, there are very few (if any) established principles for complex and safety-critical applications for an accelerator. This paper argues for the importance of established HF and UX principles (herein referred to as human-centered design principles) into the development of accelerator HSIs, emphasizing the need for clarity, consistency, responsiveness, and cognitive accessibility. Drawing from HF/UX best practices and human-centered design, this paper discusses how these approaches can enhance operator performance, reduce human error, and improve accelerator personnel collaboration. Case studies from Accelerator Control Operations Research Network (ACORN) at Fermilab are explored to demonstrate how interfaces built with human-centered design principles can scale with system complexity while remaining intuitive and efficient for diverse user roles including operators, machine experts, and engineers. By bridging the gap between traditional control system design and modern human-centered design methods, this paper provides a roadmap for evolving accelerator HSIs into more usable, maintainable, and effective tools.

Hill, Rachael [Idaho Natl. Lab.]↗

Qualification Plus: Performance and Durability Tests Beyond IEC 61215 (Presentation)

Qualification Plus is an accelerated test protocol and quality management system that gives higher confidence in field performance of PV modules compared with conventional qualification testing. The test sequences are being developed as consensus standards, but the early publication of these tests enables the community to begin benefiting from them sooner.

14 SOLAR ENERGY↗

SU-E-T-406: Evaluation of the Stealth Chamber by IBA Under Large Field Conditions

Purpose: To evaluate the performance of the stealth chamber by IBA under large field conditions. Methods: Measurement of PDDs and profiles for fields of 10×10, 15×15, 20×20 and 25×25 cm2 were acquired in a blue phantom2 scanning system for 6 and 15 MV beams in a Varian TrueBeam linear accelerator. The stealth chamber has a field size limit of 25×25 cm2. Measurements with two different detector set were performed. First a cc13 chamber as field and reference chamber was acquired. And with a cc13 chamber as field detector and the stealth chamber as the reference chamber. PDDs for the fields mentioned above were conducted and profiles with the same fields at depth of dmax, 5, 10 and 20 cm were acquired for comparison. Results: Examination of the PDDs and profile comparison with a criterion of 1% and 1 mm agreement was performed. Very good agreement between the cc13 and stealth chamber set was observed within the chosen criterion. Conclusion: This work indicates the comparable results obtained with the use of the stealth chamber and cc13 as the reference chamber in relative dosimetry measurements.

43 PARTICLE ACCELERATORS↗

Tensile performance of sustainable Strain-Hardening Cementitious Composites with hybrid PVA and recycled PET fibers

Highlights: • SHCCs with hybrid PVA/PET fibers are theoretically and experimentally studied. • A semi-empirical way to predict strain capacity of hybrid-fiber SHCCs is proposed. • The impacts of PET fiber surface treatment and curing time are explored. • SHCCs achieve satisfactory performance even 50% PVA fibers are replaced by PET fibers. • Using PET fibers in SHCCs effectively reduces material cost and environmental impact. - Abstract: Strain-Hardening Cementitious Composite (SHCC) is a type of advanced construction material that can enhance the resiliency and durability of structures. However, the high cost of the constituents limits the wide application of SHCCs. To reduce the material cost and improve the sustainability, this study explores the potential of replacing commonly-used polyvinyl alcohol (PVA) fibers by recycled polyethylene terephthalate (PET) fibers. The potential of fiber hybridization was first evaluated using micromechanical modeling, and the ultimate tensile strain of hybrid-fiber SHCCs was estimated using a semi-empirical method. Then the tensile performance of SHCCs after standard curing and accelerated aging was experimentally evaluated, and the crack pattern development with increasing tensile strain was recorded. Satisfactory mechanical performance can be achieved even when 50% of PVA fibers are replaced by recycled PET fibers with surface treatment. In addition, using recycled PET fibers in SHCCs can significantly reduce the material cost and environmental impact.

36 MATERIALS SCIENCE↗

Electron Pre-acceleration at Nonrelativistic High-Mach-number Perpendicular Shocks

We perform particle-in-cell simulations of perpendicular nonrelativistic collisionless shocks to study electron heating and pre-acceleration for parameters that permit the extrapolation to the conditions at young supernova remnants. Our high-resolution large-scale numerical experiments sample a representative portion of the shock surface and demonstrate that the efficiency of electron injection is strongly modulated with the phase of the shock reformation. For plasmas with low and moderate temperature (plasma beta β{sub p}=5⋅10{sup −4} and β{sub p}=0.5), we explore the nonlinear shock structure and electron pre-acceleration for various orientations of the large-scale magnetic field with respect to the simulation plane, while keeping it at 90° to the shock normal. Ion reflection off of the shock leads to the formation of magnetic filaments in the shock ramp, resulting from Weibel-type instabilities, and electrostatic Buneman modes in the shock foot. In all of the cases under study, the latter provides first-stage electron energization through the shock-surfing acceleration mechanism. The subsequent energization strongly depends on the field orientation and proceeds through adiabatic or second-order Fermi acceleration processes for configurations with the out-of-plane and in-plane field components, respectively. For strictly out-of-plane field, the fraction of suprathermal electrons is much higher than for other configurations, because only in this case are the Buneman modes fully captured by the 2D simulation grid. Shocks in plasma with moderate β{sub p} provide more efficient pre-acceleration. The relevance of our results to the physics of fully 3D systems is discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

Simulation of EAS properties on the basis of high energy interaction model deduced from the accelerator data

Calculations of extensive air showers in atmosphere were performed using formulae describing p-p and p-air nucleus interactions. The formulae fitted to the accelerator data were extrapolated taking the same trend up to 10 to the 16 eV. Above that energy it was assumed that the degree of scaling violating/alpha-parameter/ is saturating or even decreasing. The latter assumption follows from earlier work where it was found that without this restriction shower maxima at the highest energies are located too high in the atmosphere. Results of calculations have been compared with experimental data. The comparison was made separately for the curves obtained from the so called equal intensity cuts and for the Cerenkov data.

Kubiak, G.↗

The performance evaluation of direct detection electron energy-loss spectroscopy at 200 kV and 80 kV accelerating voltages

Direct electron detectors (DeDs) have been widely used for imaging studies because of their higher beam sensitivity, lower noise, improved pixel resolution, etc. However, there have been limited studies related to the performance in spectroscopic applications for the direct electron detection. Hereby, taking the advantage of the DeD installed on a high-performance electron energy-loss spectrometer, we systematically studied the performance of a DeD (Gatan's K2 IS) fitted on an aberration-corrected transmission electron microscope (TEM) equipped with an electron monochromator. Using SrTiO3 as the model system, the point spread function in the zero-loss region of the spectrum and the performance for core loss spectroscopy have been investigated under both 200 kV and 80 kV operating conditions. We demonstrate that the K2 detector can achieve an overall better performance at 200 kV than a charge coupled device (CCD) detector. At 80 kV, the K2 DeD is still better than a CCD, except for the relative broad tails of the zero-loss peak. The signal-to-noise ratio is very close for DeD and CCD under 80 kV. Based on our data obtained at different operating voltages, it is clear that DeD will benefit the microscopy community and boost the development of cutting-edge materials science studies by pushing the frontiers in electron energy-loss spectroscopy.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗