Search NASA⌕ Search

SEARCH · Search NASA

Results for “code verification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Verification and application of resonance broadened quasi-linear (RBQ) model with multiple Alfvénic instabilities

The resonance broadened quasilinear (RBQ) model for the problem of relaxing the hot ion distribution function in constant-of-motion 3D space [Gorelenkov et al., Nucl. Fusion 58, 082016 (2018)] is presented with the self-consistent evolution of multiple Alfvén eigenmode amplitudes. The RBQ model represents the generalization of the earlier published model [Berk et al., Nucl. Fusion 35, 1661 (1995)] by carefully examining the wave particle interaction in the presence of realistic Alfvén eigenmode (AE) structures and pitch angle scattering with the help of the guiding center code ORBIT. One aspect of the generalization is that the RBQ model goes beyond the local perturbative-pendulumlike approximation for the wave particle dynamics near the resonance. An iterative procedure is introduced to account for eigenstructures varying within the resonances. It is found that a radially localized mode structure implies a saturation level 2–3 times smaller than that predicted by an earlier bump-on-tail quasilinear model that employed uniform mode structures. We apply the RBQ code to a DIII-D plasma with an elevated q-profile where the beam ion profiles exhibit stiff transport properties [Collins et al., Phys. Rev. Lett. 116, 095001 (2016)]. Finally, the properties of AE driven fast ion distribution relaxation are studied for validations of the applied RBQ model in DIII-D discharges. Initial results show that the model is robust, is numerically efficient, and can predict fast ion relaxation in present and future burning plasma experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Synthetic Diagnostics Platform for Fusion Plasma and a Two-Dimensional Synthetic Electron Cyclotron Emission Imaging Code

Magnetic confinement fusion is one of the most promising approaches to achieve fusion energy. With the rapid increase of the computational power over the past decades, numerical simulation have become an important tool to study the fusion plasmas. Eventually, the numerical models will be used to predict the performance of future devices, such as the International Thermonuclear Experiment Reactor (ITER) or DEMO. However, the reliability of these models needs to be carefully validated against experiments before the results can be trusted. The validation between simulations and measurements is hard particularly because the quantities directly available from both sides are different. While the simulations have the information of the plasma quantities calculated explicitly, the measurements are usually in forms of diagnostic signals. The traditional way of making the comparison relies on the diagnosticians to interpret the measured signals as plasma quantities. The interpretation is in general very complicated and sometimes not even unique. In contrast, given the plasma quantities from the plasma simulations, we can unambiguously calculate the generation and propagation of the diagnostic signals. These calculations are called synthetic diagnostics, and they enable an alternate way to compare the simulation results with the measurements. In this dissertation, we present a platform for developing and applying synthetic diagnostic codes. Three diagnostics on the platform are introduced. The reflectometry and beam emission spectroscopy diagnostics measure the electron density, and the electron cyclotron emission diagnostic measures the electron temperature. The theoretical derivation and numerical implementation of a new two dimensional Electron cyclotron Emission Imaging code is discussed in detail. This new code has shown the potential to address many challenging aspects of the present ECE measurements, such as runaway electron effects, and detection of the cross phase between the electron temperature and density fluctuations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Preliminary Study of In-House Monte Carlo Simulations: An Integrated Monte Carlo Verification System

Purpose: To develop an infrastructure for the integrated Monte Carlo verification system (MCVS) to verify the accuracy of conventional dose calculations, which often fail to accurately predict dose distributions, mainly due to inhomogeneities in the patient's anatomy, for example, in lung and bone. Methods and Materials: The MCVS consists of the graphical user interface (GUI) based on a computational environment for radiotherapy research (CERR) with MATLAB language. The MCVS GUI acts as an interface between the MCVS and a commercial treatment planning system to import the treatment plan, create MC input files, and analyze MC output dose files. The MCVS consists of the EGSnrc MC codes, which include EGSnrc/BEAMnrc to simulate the treatment head and EGSnrc/DOSXYZnrc to calculate the dose distributions in the patient/phantom. In order to improve computation time without approximations, an in-house cluster system was constructed. Results: The phase-space data of a 6-MV photon beam from a Varian Clinac unit was developed and used to establish several benchmarks under homogeneous conditions. The MC results agreed with the ionization chamber measurements to within 1%. The MCVS GUI could import and display the radiotherapy treatment plan created by the MC method and various treatment planning systems, such as RTOG and DICOM-RT formats. Dose distributions could be analyzed by using dose profiles and dose volume histograms and compared on the same platform. With the cluster system, calculation time was improved in line with the increase in the number of central processing units (CPUs) at a computation efficiency of more than 98%. Conclusions: Development of the MCVS was successful for performing MC simulations and analyzing dose distributions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Verification of the Prompt Radiation Shielding Design of the ESS Accelerator

Fermilab will perform prompt radiation and shielding verification studies for the European Spallation Source ERIC (ESS) accelerator tunnel and existing penetration layouts using the latest information on the beam line and existing models of magnets and cryomodules. The input information about the assumptions, geometry layout, etc. will be provided by the Safety Group (accelerator division, ESS). The MEDT department of the Accelerator Division, Fermilab will provide the results of the studies. MARS15, a Fermilab a multi-purpose Monte-Carlo code developed since 1974, is at the heart of this effort. MARS15 is used for detailed simulation of hadronic and electromagnetic cascades in an arbitrary 3-D geometry of shielding, accelerator, detector and spacecraft components with energy ranging from a fraction of an electronvolt to 100 TeV. This work will provide additional validation of recent additions to the physical models in the code, including the code capabilities to simulate cascades and generate a variety of results in complex media.

43 PARTICLE ACCELERATORS↗

High-to-Low Activities across VVI, AMA and PHI

This milestone report documents work performed in CASL that was broadly focused on the use of validated high-fidelity simulation codes to inform, improve and calibrate low-fidelity codes to facilitate multiphysics coupling, design, performance analysis, and risk assessment. This high-to-low (Hi2Lo) initiative has the following objectives: employ physics encapsulated in high-fidelity codes to improve the functionality of low-fidelity codes, quantify biases in low-fidelity codes, develop and calibrate physical models and closure relations so that low-fidelity codes more accurately incorporate requisite physics, and develop low-fidelity codes that can be effectively coupled to simulate multiphysics behavior. In combination, these efforts are designed to impact both CIPS and DNB. For example, the development and experimental design-based Bayesian calibration of dynamic gas conductance models in CTFFuel will provide the capability to better model crud-induced power shifts. Whereas the present emphasis has focused on the high-fidelity codes STAR-CCM+ and BISON and low-fidelity codes CTF and CTFFuel, future emphasis will be expanded to include MAMBA. During the reporting period, Hi2Lo efforts focused on two broad components: demonstration of the experimental design-based Bayesian calibration framework to calibrate CTF using both STAR-generated synthetic data and experimental data, and the use of STAR to inform and improve the turbulence modeling and grid heat transfer modeling capabilities in CTF. A complementary milestone focused on the implementation and verification of fuel models in CTFFuel, for which we demonstrated initial calibration results. Future Hi2Lo work will focus on the use of the experimental design-based Bayesian calibration framework, demonstrated this year for STAR and CTF, to calibrate parameters in the fuel swelling, fuel irradiation-induced densification, and fuel relocation models in CTFFuel using both experimental and BISON-generated data. A second component will focus on the continued use of STAR to improve grid modeling capabilities in CTF.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Verification of R-matrix calculations for charged-particle reactions in the resolved resonance region for the 7 Be system

R-matrix theory is used to present nuclear reactions in the resolved resonance region. It uses information on bound states and low energy resonances to accurately parametrize cross sections on the resonances as well as the non-resonant background. Since the seminal work of Lane and Thomas (1958), the method has been widely used to analyze experimental cross-section data in a broad range of fields spanning nuclear reaction dynamics, nuclear astrophysics, ion beam analysis and their applications. Different R-matrix codes have been developed and used in these different applications with very little communication among the developers or practitioners on the capabilities, achievements or limitations of the codes. A limited comparison among three R-matrix codes on neutron-induced reactions was performed by the International Atomic Energy Agency (IAEA) International Evaluation of Neutron Cross Section Standards project (2007). Since then, significant progress has been made in their implementation of the R-matrix algorithms, and R-matrix codes have enhanced capabilities. In this paper we introduce, for the first time, the results of a comprehensive effort to verify the most widely used R-matrix codes in the various fields of nuclear science and applications: AMUR, AZURE2, CONRAD, EDA, FRESCO, GECCCOS, and SAMMY. In addition to the description of the capabilities of the codes and their specifications, we discuss the results of a joint exercise which was coordinated by the International Atomic Energy Agency. The aim of the exercise was to compare calculations of charged-particle reaction cross sections for the light composite system 7Be. The calculations were performed by the codes using identical input R-matrix parameters and other specifications and were limited to charged-particle channels.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Implications of Artefacts Reduction in the Planning CT Originating from Implanted Fiducial Markers

The efficacy of metal artefact reduction (MAR) software to suppress artefacts in reconstructed computed tomography (CT) images originating from small metal objects, like tumor markers and surgical clips, was evaluated. In addition, possible implications of using digital reconstructed radiographs (DRRs), based on the MAR CT images, for setup verification were analyzed. A phantom and 15 patients with different tumor sites and implanted markers were imaged with a multislice CT scanner. The raw image data was reconstructed both with the clinically used filtered-backprojection (FBP) and with the MAR software. Using the MAR software, improvements in image quality were often observed in CT slices with markers or clips. Especially when several markers were located near to each other, fewer streak artefacts were observed than with the FBP algorithm. In addition, the shape and size of markers could be identified more accurately, reducing the contoured marker volumes by a factor of 2. For the phantom study, the CT numbers measured near to the markers corresponded more closely to the expected values. However, the MAR images were slightly more smoothed compared with the images reconstructed with FBP. For 8 prostate cancer patients in this study, the interobserver variation in 3D marker definition was similar (<0.4 mm) when using DRRs based on either FBP or MAR CT scans. Automatic marker matches also showed a similar success rate. However, differences in automatic match results up to 1 mm, caused by differences in the marker definition, were observed, which turned out to be (borderline) statistically significant (p = 0.06) for 2 patients. In conclusion, the MAR software might improve image quality by suppressing metal artefacts, probably allowing for a more reliable delineation of structures. When implanted markers or clips are used for setup verification, the accuracy may slightly be improved as well, which is relevant when using very tight clinical target volume (CTV) to planning target volume (PTV) margins for planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Vision and Development of a Design, Implementation, and Verification Automation (DIVA) Software Platform for DNA Construction

Abstract DNA construction, while a prerequisite to many biological endeavors, is often a time-consuming distraction from an individual’s primary research objectives. We envisioned that with the right software infrastructure and cultural mindset, a single person could execute in parallel the batched DNA construction tasks of an entire research institute, at scales realizing efficiency gains through process and laboratory automation. In pursuit of this vision, we developed the Design, Implementation, and Verification Automation (DIVA) software platform. DIVA’s web interface enables researchers to design DNA constructs (using visual biological computer-aided design tools and biological parts repositories), submit designs for construction to dedicated staff, and track DNA construction as it progresses. DIVA supports the dedicated staff through the DNA construction process and records both successful and unsuccessful attempts toward improving the overall process. The platform is publicly available at public-diva.jbei.org and its open-source code through github.com/JBEI/DIVA.

Plahar, Hector [DOE Agile BioFoundry , , ,; DOE Jo↗

SU-F-T-610: Comparison of Output Factors for Small Radiation Fields Used in SBRT Treatment

Purpose: In order to fundamentally understand our previous dose verification results between measurements and calculations from treatment planning system (TPS) for SBRT plans for different sized targets, the goal of the present work was to compare output factors for small fields measured using EDR2 films with TPS and Monet Carlo (MC) simulations. Methods: 6MV beam was delivered to EDR2 films for each of the following field sizes; 1×1 cm{sup 2}, 1.5×1.5 cm{sup 2}, 2×2 cm{sup 2}, 3×3 cm{sup 2}, 4×4 cm{sup 2}, 5×5 cm{sup 2} and 10×10 cm{sup 2}. The films were developed in a film processer, then scanned with a Vidar VXR-16 scanner and analyzed using RIT113 version 6.1. A standard calibration curve was obtained with the 6MV beam and was used to get absolute dose for measured field sizes. Similar plans for all fields sizes mentioned above were generated using Eclipse with the Analytical Anisotropic Algorithm. Similarly, MC simulations were carried out using the MCSIM, an in-house MC code for different field sizes. Output factors normalized to 10×10 cm{sup 2} reference field were calculated for different field sizes in all the three cases and compared. Results: For field sizes ranging from 1×1 cm{sup 2} to 2×2 cm{sup 2}, the differences in output factors between measurements (films), TPS and MC simulations were within 0.22%. For field sizes ranging from 3×3cm{sup 2} to 5×5cm{sup 2}, differences in output factors were within 0.10%. Conclusion: No clinically significant difference was obtained in output factors for different field sizes acquired from films, TPS and MC simulations. Our results showed that the output factors are predicted accurately from TPS when compared to the actual measurements and superior dose calculation Monte Carlo method. This study would help us in understanding our previously obtained dose verification results for small fields used in the SBRT treatment.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP3-09: Tumor Location Prediction Using Natural Respiratory Volume for Respiratory Gated Radiation Therapy (RGRT): System Verification Study

Purpose: Respiratory gated radiation therapy (RGRT) gives accurate results when a patient’s breathing is stable and regular. Thus, the patient should be fully aware during respiratory pattern training before undergoing the RGRT treatment. In order to bypass the process of respiratory pattern training, we propose a target location prediction system for RGRT that uses only natural respiratory volume, and confirm its application. Methods: In order to verify the proposed target location prediction system, an in-house phantom set was used. This set involves a chest phantom including target, external markers, and motion generator. Natural respiratory volume signals were generated using the random function in MATLAB code. In the chest phantom, the target takes a linear motion based on the respiratory signal. After a four-dimensional computed tomography (4DCT) scan of the in-house phantom, the motion trajectory was derived as a linear equation. The accuracy of the linear equation was compared with that of the motion algorithm used by the operating motion generator. In addition, we attempted target location prediction using random respiratory volume values. Results: The correspondence rate of the linear equation derived from the 4DCT images with the motion algorithm of the motion generator was 99.41%. In addition, the average error rate of target location prediction was 1.23% for 26 cases. Conclusion: We confirmed the applicability of our proposed target location prediction system for RGRT using natural respiratory volume. If additional clinical studies can be conducted, a more accurate prediction system can be realized without requiring respiratory pattern training.

60 APPLIED LIFE SCIENCES↗

Validation of electron backscattering in the MCNP6.3 code

A new electron backscattering validation suite has been developed for the MCNP® code. The calculations in this suite cover both condensed history and single-event transport methods, seven different elemental materials ranging from beryllium to uranium, and incident electron energies from 200 eV to 14.1 MeV. In general, the accuracy of the MCNP code for electron backscattering calculations is energy-dependent. For incident electron energies below 2 keV, the condensed history method is not applied while the single-event method shows poor agreement with experimental measurements due to poor accuracy of the underlying atomic data. For incident energies between 2 keV and 256 keV, the single-event method typically shows better agreement with experiments, while for incident energies above 256 keV the condensed history method gives better accuracy. Additionally, agreement with experimental data is generally worse for low- Z materials such as beryllium and carbon, which may reflect deficiencies in the data or physics underlying electron transport through light elements in the MCNP code. The new electron backscattering validation suite, along with the previously introduced electron stopping power and Lockwood energy deposition validation suites, provide MCNP users with a quantified understanding of the uncertainties in electron transport calculations. Future improvements to electron transport in the MCNP code are necessary for low energies (≤ 2 keV) and for low- Z materials.

36 MATERIALS SCIENCE↗

Progress with the COGENT Edge Kinetic Code: Implementing the Fokker-Plank Collision Operator

Here, COGENT is a continuum gyrokinetic code for edge plasma simulations being developed by the Edge Simulation Laboratory collaboration. The code is distinguished by application of a fourth-order finite-volume (conservative) discretization, and mapped multiblock grid technology to handle the geometric complexity of the tokamak edge. The distribution function F is discretized in v∥ – μ (parallel velocity – magnetic moment) velocity coordinates, and the code presently solves an axisymmetric full-f gyro-kinetic equation coupled to the long-wavelength limit of the gyro-Poisson equation. COGENT capabilities are extended by implementing the fully nonlinear Fokker-Plank operator to model Coulomb collisions in magnetized edge plasmas. The corresponding Rosenbluth potentials are computed by making use of a finite-difference scheme and multipole-expansion boundary conditions. Details of the numerical algorithms and results of the initial verification studies are discussed. (© 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MO-F-16A-01: Implementation of MPPG TPS Verification Tests On Various Accelerators

Purpose: To demonstrate the implementation of the Medical Physics Practice Guideline (MPPG) for dose calculation and beam parameters verification of treatment planning systems (TPS). Methods: We implemented the draft TPS MPPG for three linacs: Varian Trilogy, TomoHDA and Elekta Infinity. Static and modulated test plans were created. The static fields are different than used in commissioning. Data was collected using ion chambers and diodes in a scanning water tank, Delta4 phantom and a custom phantom. MatLab and Microsoft Excel were used to create analysis tools to compare reference DICOM dose with scan data. This custom code allowed for the interpolation, registration and gamma analysis of arbitrary dose profiles. It will be provided as open source code. IMRT fields were validated with Delta4 registration and comparison tools. The time for each task was recorded. Results: The tests confirmed the strengths, and revealed some limitations, of our TPS. The agreement between calculated and measured dose was reported for all beams. For static fields, percent depth dose and profiles were analyzed with criteria in the draft MPPG. The results reveal areas of slight mismatch with the model (MLC leaf penumbra, buildup region.) For TomoTherapy, the IMRT plan 2%/2 mm gamma analysis revealed poorest agreement in the low dose regions. For one static test plan for all 10MV Trilogy photon beams, the plan generation, scan queue creation, data collection, data analysis and report took 2 hours, excluding tank setup. Conclusions: We have demonstrated the implementation feasibility of the TPS MPPG. This exercise generated an open source tool for dose comparisons between scan data and DICOM dose data. An easily reproducible and efficient infrastructure with streamlined data collection was created for repeatable robust testing of the TPS. The tests revealed minor discrepancies in our models and areas for improvement that are being investigated.

07 ISOTOPE AND RADIATION SOURCES↗

Design and Integrate Improved Systems for Nuclear Facility Ventilation and Exhaust Operations

Objective: The objective of this R&D project would complete the development of three new systems and integrate them into a single experimental effort. However, each of the three systems has stand-alone applicability across the DOE complex. At US DOE nuclear facilities, indoor air is filtered and ventilated for human occupancy, and exhaust air to the outdoor environment must be regulated and monitored. At least three technical standards address these functions, and the Los Alamos National Laboratory would complete an experimental facility to answer at least three questions: (1) Can the drag coefficient of a new Los Alamos air mixer be reduced for better operation in nuclear facility exhaust stacks? (2) Is it possible to verify the accuracy of a new dilution method for HEPA filter test facilities? (3) Is there a performance-based air flow metric (volumetric flow or mass flow) for operating HEPA filters? In summary, the three new systems are: a mixer, a diluter and a performance-based metric, respectively. The results of this project would be applicable to at least four technical standards: ANSI N13.1 Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stacks and Ducts of Nuclear Facilities; ASTM F1471 Standard Test Method for Air Cleaning Performance of a High-Efficiency Particulate Air Filter System, ASME N511: In-Service Testing of Nuclear Air Treatment, Heating, Ventilating, and Air-Conditioning Systems, and ASME AG-1: Code On Nuclear Air And Gas Treatment. All of the three proposed new systems must be combined into a single experimental device (i.e. to develop a new function of the Los Alamos aerosol wind tunnel). Technical Approach: The Radiation Protection RP-SVS group at Los Alamos has an aerosol wind tunnel that was originally (2006) designed to evaluate small air samplers (cf. US EPA 40 CFR 53.42). In 2009, the tunnel was modified for exhaust stack verifications per the ANSI N13.1 standard. In 2010, modifications were started on the wind tunnel for testing HEPA filters (cf. ASTM F1471 and ASME N511). This project involves three systems that were developed for testing the 24*24*11 (inch) HEPA filters (i.e. the already mentioned mixer, diluter and metric). Prototypes of the mixer and the diluter have been built and individually tested on a preliminary basis. However, the third system (the HEPA metric method) has not been tested, since that requires complete operability of the aerosol wind tunnel device. (The experimental wind tunnel has test aerosol injection, control and measurement capabilities, and can be heated for temperature dependent measurements.) Benefits: US DOE facilities that use HEPA filters and/or require exhaust stacks from their nuclear facility buildings will benefit from access to the new hardware (mixer and diluter) and performance-based metric (for HEPA filter air flow).

61 RADIATION PROTECTION AND DOSIMETRY↗

North Dakota Integrated Carbon Storage Complex Feasibility Study. Final report

In spring 2017, the Energy & Environmental Research Center (EERC) initiated an effort to determine the feasibility of developing a commercial-scale CO 2 geologic storage complex able to store 50+ million tonnes (Mt) of CO 2 in central North Dakota safely, permanently, and economically. The objective was to fulfill the goals of the U.S. Department of Energy (DOE) Carbon Storage Assurance Facility Enterprise (CarbonSAFE) Initiative and address technical and nontechnical challenges specific to commercial-scale deployment of a CO2 storage project. The findings clearly show that the concept of capturing CO 2 from a lignite-fired electrical generation facility in central North Dakota and safely and permanently storing the CO 2 in the deep subsurface is indeed technically, economically, and socially feasible. This project evaluated two study areas and their respective geologic storage complexes located adjacent to separate coal-fired facilities in North Dakota: the Basin Electric Power Cooperative (BEPC)-owned Great Plains Synfuels Plant (GPSP) and the Minnkota Power Cooperative (Minnkota)-owned Milton R. Young Station (MRYS). These locations, one with CO 2 capture in place and an existing CO 2 pipeline, are bolstered by progressive North Dakota pore space ownership and long-term liability laws. These elements and a motivated team created an ideal synergistic scenario for ensuring success of the CarbonSAFE Initiative and promoting North Dakota’s statewide vision for carbon management. The project included drilling two new geologic characterization wells, integrating an existing 3-D seismic survey, creating a geologic model subsequently used for injection simulation, a risk assessment, public outreach, and generating a site development plan based on results. In addition, the performance of select National Risk Assessment Partnership tools was evaluated. The geologic characterization wells were drilled ~5600 feet deep to the Broom Creek Formation; ~350 feet of core was retrieved from each well. The core included the Broom Creek (targeted injection zone) and a portion of the overlying Opeche Shale (seal). The Flemmer-1 well, west of Beulah, North Dakota, yielded 169 feet of sandstone. The BNI-1 well located south of Center, North Dakota, yielded 124 feet of sandstone. In each case, laboratory analysis of the sandstone showed permeability in the 300–1000-mD range, with porosity of 20%–30%. The Flemmer-1 well was sited within the boundaries of an existing 3-D seismic survey. Colocating the well with the seismic survey maximized the relationship between new and legacy data and developed a first-of-its-kind interpretation of the geologic fabric of the Broom Creek. Geologic characterization data were integrated into a 5544-mi 2 geocellular model that encompassed both new wells and stratigraphy from the surface to the Amsden Formation (underlying the Broom Creek). The model was later expanded vertically to include the deeper Black Island–Deadwood interval to examine its potential viability as a storage target. The geocellular model provided the foundation for dynamic simulation of CO 2 into the Broom Creek. Results of the simulation suggest that the Broom Creek could accept the DOE target rate of 2 Mt/yr of CO 2 into as few as two wells. To bracket the expected capture from MRYS, simulations were also investigated for a 4-Mt/yr rate near MRYS. Although more wells are needed (two additional), the Broom Creek still has the storage resource to accept the CO 2 at the increased rate. A risk assessment exercise was conducted to identify and assess technical and nontechnical risks that could prevent potential candidate storage complexes within the study area from serving as commercial storage sites. The assessment identified and evaluated six technical risk categories: 1) CO 2 injectivity, 2) storage capacity, 3) lateral migration of CO 2 , 4) lateral pressure propagation, 5) vertical migration of CO 2 or formation brine, and 6) induced seismicity. Following two rounds of analysis and scoring, no risks were determined to preclude continued efforts to develop carbon capture, utilization, and storage (CCUS) in central North Dakota. The risk assessment results will be used to guide future site characterization, modeling and simulation, and monitoring activities. A specific nontechnical strategic risk based on challenges that may be realized in amalgamation of pore space resulted in vertically expanding the geologic model to incorporate the potential for stacked storage in multiple saline reservoirs. By including the Black Island–Deadwood interval (the basal sedimentary reservoir in this region), the amalgamated areal extent could be reduced by as much as 45%. Working with a smaller geographic area reduces risks and costs associated with monitoring and pore space leasing. An economic evaluation incorporating capture; transport (<5 mi); Class VI wells; permitting; and monitoring, verification, and accounting suggests implementing commercial-scale CCUS is economically attractive if the federal tax benefits of 45Q are included. This is validated by Minnkota’s continued pursuit of CO 2 capture and geologic storage at MRYS through its Project Tundra initiative, indicating that there is a business case for CCUS in central North Dakota. Currently, North Dakota is the only state with underground injection control (UIC) Class VI primacy. Built into the North Dakota Century Code is a series of regulatory requirements that guide the process to obtain a Class VI CO 2 storage facility permit. As part of this project, a site development plan was compiled to assure compliance with North Dakota’s requirements to permit a commercial-scale CO 2 storage operation and includes a prospective time line encompassing a general breakdown of activities. In total, an estimated 30 months would be needed to execute the necessary steps to attain a North Dakota CO 2 storage facility permit. Outreach was an integral part of the project and encompassed any project-related activity that had contact or exposure beyond the project team. The goals of outreach were to foster an environment from which stakeholders could make informed decisions about the project and gauge community receptiveness to a CCUS project. A consistent set of messages and outreach products were developed in conjunction with an outreach advisory board that integrated project partners and team members. To gauge public acceptability of geologically storing CO 2 , 5611 households in the project area were invited to participate in an online survey. The survey results indicate that the public attitude regarding CCUS is neutral to positive, with strong sentiment that CO 2 capture and storage may be an approach to maintain the economic vitality of the region. To achieve project objectives, critical support in the form of financial backing, engineering evaluations, site access, outreach collaboration, operations data, risk assessment/evaluation, and software access was provided by BEPC, the North Dakota Industrial Commission Lignite Research Council, ALLETE Clean Energy, BNI Energy, North American Coal Corporation, Minnkota, Prairie Public Broadcasting, Computer Modelling Group Ltd., and Schlumberger.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Development of a Standard for Verification and Validation of Software Used to Calculate Nuclear System Thermal Fluids Behavior

With the resurgence of nuclear power and increased interest in advanced nuclear reactors as an option to supply abundant energy without the associated greenhouse gas emissions of the more conventional fossil fuel energy sources, there is a need to establish internationally recognized standards for the verification and validation (V&V) of software used to calculate the thermal-hydraulic behavior of advanced reactor designs for both normal operation and hypothetical accident conditions. To address this need, ASME (American Society of Mechanical Engineers) Standards and Certification has established the V&V 30 Committee, under the responsibility of the V&V Standards Committee, to develop a consensus Standard for verification and validation of software used for design and analysis of advanced reactor systems. The initial focus of this committee will be on the V&V of system analysis and computational fluid dynamics (CFD) software for nuclear applications. To limit the scope of the effort, the committee will further limit its focus to software to be used in the licensing of High-Temperature Gas-Cooled Reactors. In this framework, the standard should conform to Nuclear Regulatory Commission (NRC) practices, procedures and methods for licensing of nuclear power plants as embodied in the United States (U.S.) Code of Federal Regulations and other pertinent documents such as Regulatory Guide 1.203, “Transient and Accident Analysis Methods” and NUREG-0800, “NRC Standard Review Plan”. In addition, the standard should be consistent with applicable sections of ASME Standard NQA-1 (“Quality Assurance Requirements for Nuclear Facility Applications (QA)”). This paper describes the general requirements for the V&V Standard, which includes; (a) the definition of the operational and accident domain of a nuclear system that must be considered if the system is to licensed, (b) the corresponding calculational domain of the software that should encompass the nuclear operational and accident domain to be used to study the system behavior for licensing purposes, (c) the definition of the scaled experimental data set required to provide the basis for validating the software, (d) the ensemble of experimental data sets required to populate the validation matrix for the software in question, and (e) the practices and procedures to be used when applying a validation standard. Although this initial effort will focus on software for licensing of High-Temperature Gas Reactors, it is anticipated that the practices and procedures developed for this standard can eventually be extended to other nuclear and non-nuclear applications.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

CLimate Impact: Determining Etiology thRough pAthways (CLDERA)

Climate impacts have broad economic, health, political, and national security ramifications. Societally relevant impacts are typically farther downstream, are the product of multiple interacting processes, and can arise over small regions and timeframes because their sources are short-term and localized. Short-term forcings (as can be seen in volcanic eruptions, climatic tipping points (e.g., the collapse of rainforests or the disappearance of sea ice), or in increasingly plausible climate interventions) fundamentally possess low signal-to-noise and could benefit from accounting for the multiple conditional processes through which a downstream impact arises. Under the Grand Challenge LDRD CLDERA (CLimate impacts: Discovering Etiology thRough pAthways), we have developed tools to enable downstream impact attribution from geographically and temporally localized source forcings in the climate. CLDERA developed methods that can distinguish how a localized source drives the climate system to respond with particular impacts. The how is embodied in pathways – the spatio-temporally evolving chain of physical processes that connects a source to a series of increasingly distant impacts. Novel analytic methods in pursuit of downstream impact attribution were developed and demonstrated on simulations and observations of the 1991 eruption of Mt. Pinatubo in the Philippines. As described within this report we have • developed stratospheric expertise and aerosol modeling capabilities in E3SM, • created original methods to detect and model pathways from source-to-impact, and • advanced climate attribution through novel methods, cases, and approaches. Further, CLDERA developed a tiered verification process consisting of controlled datasets to prototype, verify, and refine the original method development. CLDERA increased Sandia’s footprint in the climate analytics community and developed new climate collaborations whilst also creating a cadre of climate analysts at Sandia. The products from CLDERA have been extensive with a total of 9 journal articles published, 12 articles submitted and under review, and an additional 8 articles in preparation. We have produced 1750 simulated years and developed 9 code-bases. This report details these accomplishments and serves as a summary of the work completed during the CLDERA Grand Challenge.

54 ENVIRONMENTAL SCIENCES↗

Development of a Consensus Standard for Verification and Validation of Nuclear System Thermal-Fluids Software

With the resurgence of nuclear power and increased interest in advanced nuclear reactors as an option to supply abundant energy without the associated greenhouse gas emissions of the more conventional fossil fuel energy sources, there is a need to establish internationally recognized standards for the verification and validation (V&V) of software used to calculate the thermal-hydraulic behavior of advanced reactor designs for both normal operation and hypothetical accident conditions. To address this need, ASME (American Society of Mechanical Engineers) Standards and Certification has established the V&V 30 Committee, under the jurisdiction of the V&V Standards Committee, to develop a consensus standard for verification and validation of software used for design and analysis of advanced reactor systems. The initial focus of this committee will be on the V&V of system analysis and computational fluid dynamics (CFD) software for nuclear applications. To limit the scope of the effort, the committee will further limit its focus to software to be used in the licensing of High-Temperature Gas-Cooled Reactors. In this framework, the Standard should conform to Nuclear Regulatory Commission (NRC) and other regulatory practices, procedures and methods for licensing of nuclear power plants as embodied in the United States (U.S.) Code of Federal Regulations and other pertinent documents such as Regulatory Guide 1.203, 'Transient and Accident Analysis Methods' and NUREG-0800, 'NRC Standard Review Plan'. In addition, the Standard should be consistent with applicable sections of ASME NQA-1-2008 'Quality Assurance Requirements for Nuclear Facility Applications (QA)'. This paper describes the general requirements for the proposed V&V 30 Standard, which includes; (a) applicable NRC and other regulatory requirements for defining the operational and accident domain of a nuclear system that must be considered if the system is to be licensed, (b) the corresponding calculation domain of the software that should encompass the nuclear operational and accident domain to be used to study the system behavior for licensing purposes, (c) the definition of the scaled experimental data set required to provide the basis for validating the software, (d) the ensemble of experimental data sets required to populate the validation matrix for the software in question, and (e) the practices and procedures to be used when applying a validation standard. Although this initial effort will focus on software for licensing of High-Temperature Gas-Cooled Reactors, it is anticipated that the practices and procedures developed for this Standard can eventually be extended to other nuclear and non-nuclear applications.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗