Search NASA⌕ Search

SEARCH · Search NASA

Results for “software packages”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

SU-E-T-555: A Protontherapy Inverse Treatment Planning System Prototype with Linear Energy Transfer (LET) Optimization

Purpose: Develop and benchmark an inverse treatment planning system (TPS) for proton radiotherapy integrating fast analytical dose and LET calculations in patient geometries and a dual objective function with both dose and LET components, enabling us to apply optimization techniques to improve the predicted outcome of treatments based on radiobiological models. Methods: The software package was developed in MATLAB and implements a fluence-dose calculation technique based on a pencil beam model for dose calculations and a 3D LET model based on the extension of the LET in the radial direction as a function of the predicted radiological pathway. Both models were benchmarked against commissioning data from our institution, dose calculations performed with a commercial treatment planning system and Monte Carlo simulations. The optimization is based on the adaptive simulated annealing approach . Results: The dose and LET calculations were tested in a water phantom and several real patient treatments. The pass rate for the gamma index analysis (3%/3mm) test was above 90% for all test cases analyzed, and the calculation time was of the order of seconds. The inverse planning module produced plans with a significantly higher mean LET in the target compared to traditional plans, without any loss of target coverage. The clinical relevance of this improvement is under consideration . Conclusion: The developed treatment planning system is a valuable clinical and research tool that enables us to incorporate LET effects into proton radiotherapy planning in a streamlined fashion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-19A-11: Retrospective Evaluation of Thermal Coverage by Thermobrachytherapy Seed Arrangements of Clinical LDR Prostate Implants

Purpose: The superiority of a properly-administered combination of radiation therapy and hyperthermia over radiation alone in treatment of human cancers has been demonstrated in multiple studies examining radiobiology, local control, and survival. Unfortunately, hyperthermia is not yet a common modality in oncology practice, due in part to the technical difficulty of heating a deep-seated target volume to sufficient temperature. To address this problem, our group has invented a thermobrachytherapy (TB) seed based on a commonly-used low dose-rate permanent brachytherapy seed for implant in solid tumors. Instead of the tungsten radiographic marker of the standard seed, the TB seed contains one of a self-regulating ferromagnetic alloy. Placement of a patient implanted with such seeds in an oscillating magnetic field generates heat via induction of eddy currents. We present the results of studies of the capability of clinically-realistic TB seed arrangements to adequately heat defined target volumes. Methods: Seed distributions for several past LDR prostate permanent implant brachytherapy patients were reproduced in the finite element analysis software package COMSOL Multiphysics 4.4, with the difference that TB seeds were modelled, rather than the radiation-only seeds actually used for their treatments. The implant geometries were mainly of the modified peripheral loading type; a range of prostatic volumes and blood perfusion rates likely to be seen in a clinical setting were examined. Results: According to the simulations, when distributed to optimize radiation dose, TB seeds also produce sufficient heat to provide thermal coverage of the target given proper selection of the magnetic field strength. However, the thermal distributions may be improved by additional use of hyperthermia-only seeds. Conclusion: A dual-modality seed intended as an alternative to and using the same implantation apparatus and technique as the standard LDR permanent implant seed has been successfully evaluated for its ability to provide sufficient hyperthermia in clinically-realistic implants. This work was partially supported by the National Institutes of Health (NIH) STTR Grant No. R41 CA153631-01A1.

60 APPLIED LIFE SCIENCES↗

TU-C-BRE-11: 3D EPID-Based in Vivo Dosimetry: A Major Step Forward Towards Optimal Quality and Safety in Radiation Oncology Practice

Purpose: To develop a 3D in vivo dosimetry method that is able to substitute pre-treatment verification in an efficient way, and to terminate treatment delivery if the online measured 3D dose distribution deviates too much from the predicted dose distribution. Methods: A back-projection algorithm has been further developed and implemented to enable automatic 3D in vivo dose verification of IMRT/VMAT treatments using a-Si EPIDs. New software tools were clinically introduced to allow automated image acquisition, to periodically inspect the record-and-verify database, and to automatically run the EPID dosimetry software. The comparison of the EPID-reconstructed and planned dose distribution is done offline to raise automatically alerts and to schedule actions when deviations are detected. Furthermore, a software package for online dose reconstruction was also developed. The RMS of the difference between the cumulative planned and reconstructed 3D dose distributions was used for triggering a halt of a linac. Results: The implementation of fully automated 3D EPID-based in vivo dosimetry was able to replace pre-treatment verification for more than 90% of the patient treatments. The process has been fully automated and integrated in our clinical workflow where over 3,500 IMRT/VMAT treatments are verified each year. By optimizing the dose reconstruction algorithm and the I/O performance, the delivered 3D dose distribution is verified in less than 200 ms per portal image, which includes the comparison between the reconstructed and planned dose distribution. In this way it was possible to generate a trigger that can stop the irradiation at less than 20 cGy after introducing large delivery errors. Conclusion: The automatic offline solution facilitated the large scale clinical implementation of 3D EPID-based in vivo dose verification of IMRT/VMAT treatments; the online approach has been successfully tested for various severe delivery errors.

60 APPLIED LIFE SCIENCES↗

TH-A-BRF-10: Quantification of Subject-Specific Susceptibility-Related Geometric Distortion in Clinical Liver MRI for Radiation Therapy

Purpose: Subject-specific susceptibility-induced B0 inhomogeneity affects the geometric accuracy of MRI images, with potential impact on the accuracy of treatment planning and image guidance. This study quantifies individual distortions for patients with intrahepatic tumors. Methods: Liver MRI scans of 13 patients who were enrolled in an IRB approved study were acquired on a 3T scanner (Skyra, Siemens). Clinical contrast-enhanced images were acquired by a 3D Volume Interpolated Breath-Hold Examination (VIBE) sequence with TE/TR =1.65/4.3ms, voxel size = 2.5×2.5×3mm (axial sets) or 3.5×3.5×5mm (coronal sets), and frequency-encoding (FE) bandwidth of 440Hz/pixel. B0 inhomogeneity was evaluated by acquisition of dual gradient echoes (GRE) with TE1/TE2/TR =4.92/7.38/106ms, a voxel size of 3.5×3.5×3.75mm, a FE bandwidth of 290Hz/pixel and breath-hold. The phase difference maps from the two echoes were unwrapped using a quantitative MRI analysis software package (FSL, FMRIB, Oxford, UK). The resulting calculated B0 inhomogeneity maps (ΔB0 in Hz) were converted to voxel distortion maps in the FE direction (ΔX in mm) corresponding to the VIBE images. Results: Maximum susceptibility-induced distortions were observed in the liver dome near the diaphragm. Using results from coronal VIBE images in this study as examples, we observed clusters of voxels displaced close to or greater than ΔX=3.5mm (440 Hz in ΔB0) in the VIBE images of the liver in 3 patients, and greater than 2 mm but less than 3.5 mm in 12 patients. On average, approximately 14% of imaged liver voxels had distortions ΔX>±1mm (ΔB0>±125Hz) and 1% of the voxels had ΔX>±2mm (ΔB0>±250Hz). Conclusion: Although advanced MRI techniques, like VIBE, permit faster acquisitions allowing for breath-held examinations with limited motion-induced artifacts, this study suggests that localized distortions due to subject-specific susceptibility variations can occur and require additional advanced corrections based on measuring patient-specific B0 inhomogeneity maps. The authors would like to acknowledge funding support from NIH R01EB016079 and NIH/NCI RO1 CA132834.

60 APPLIED LIFE SCIENCES↗

Poster — Thur Eve — 22: A water calorimeter for low-energy particle beams

In this work, the feasibility of absolute dose to water measurements in low-energy electron beams using a water calorimeter specifically developed for shallow measurements is established. The calorimeter design consists of a cylindrical glass vessel encased in a block of expanded polystyrene. The vessel has a front window thickness of 1.1 mm, a 4 cm radius, and is 2.5 cm in depth. The vessel-block assembly sits inside a thermally-insulated box and is air-cooled to an operating temperature of 4 °C. Radiation-induced thermal gradients were simulated in a geometric model of the calorimeter using a finite element analysis software package. 52 absorbed dose to water measurements were performed in a 6 and 8 MeV electron beam (z{sub max} of 1.32 and 1.76 cm, respectively) for 60 seconds at a repetition rate of 400 MU/min and an SSD of 120 cm. Within the vessel, the depth of measurement was set to 1.08 cm relative to the inner front window. The average measured dose to water was 59.6 ± 0.2 cGy/100 MU (6 MeV), and 63.7 ± 0.3 cGy/100 MU (8 MeV). The associated heat transfer corrections were determined to be 1.026 ± 0.003 and 1.017 ± 0.004 for the 6 and 8 MeV beams, respectively. The most significant source of uncertainty in this study was the repeatability (type A, 0.42%). It is expected that performing fewer consecutive measurements under higher dose rate conditions will improve the stability of the thermal background, thereby improving the repeatability and reducing the overall standard uncertainty.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Web-based, GPU-accelerated, Monte Carlo simulation and visualization of indirect radiation imaging detector performance

Purpose: Monte Carlo simulations play a vital role in the understanding of the fundamental limitations, design, and optimization of existing and emerging medical imaging systems. Efforts in this area have resulted in the development of a wide variety of open-source software packages. One such package, hybridMANTIS, uses a novel hybrid concept to model indirect scintillator detectors by balancing the computational load using dual CPU and graphics processing unit (GPU) processors, obtaining computational efficiency with reasonable accuracy. In this work, the authors describe two open-source visualization interfaces, webMANTIS and visualMANTIS to facilitate the setup of computational experiments via hybridMANTIS. Methods: The visualization tools visualMANTIS and webMANTIS enable the user to control simulation properties through a user interface. In the case of webMANTIS, control via a web browser allows access through mobile devices such as smartphones or tablets. webMANTIS acts as a server back-end and communicates with an NVIDIA GPU computing cluster that can support multiuser environments where users can execute different experiments in parallel. Results: The output consists of point response and pulse-height spectrum, and optical transport statistics generated by hybridMANTIS. The users can download the output images and statistics through a zip file for future reference. In addition, webMANTIS provides a visualization window that displays a few selected optical photon path as they get transported through the detector columns and allows the user to trace the history of the optical photons. Conclusions: The visualization tools visualMANTIS and webMANTIS provide features such as on the fly generation of pulse-height spectra and response functions for microcolumnar x-ray imagers while allowing users to save simulation parameters and results from prior experiments. The graphical interfaces simplify the simulation setup and allow the user to go directly from specifying input parameters to receiving visual feedback for the model predictions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deterministic absorbed dose estimation in computed tomography using a discrete ordinates method

Purpose: Organ dose estimation for a patient undergoing computed tomography (CT) scanning is very important. Although Monte Carlo methods are considered gold-standard in patient dose estimation, the computation time required is formidable for routine clinical calculations. Here, the authors instigate a deterministic method for estimating an absorbed dose more efficiently. Methods: Compared with current Monte Carlo methods, a more efficient approach to estimating the absorbed dose is to solve the linear Boltzmann equation numerically. In this study, an axial CT scan was modeled with a software package, Denovo, which solved the linear Boltzmann equation using the discrete ordinates method. The CT scanning configuration included 16 x-ray source positions, beam collimators, flat filters, and bowtie filters. The phantom was the standard 32 cm CT dose index (CTDI) phantom. Four different Denovo simulations were performed with different simulation parameters, including the number of quadrature sets and the order of Legendre polynomial expansions. A Monte Carlo simulation was also performed for benchmarking the Denovo simulations. A quantitative comparison was made of the simulation results obtained by the Denovo and the Monte Carlo methods. Results: The difference in the simulation results of the discrete ordinates method and those of the Monte Carlo methods was found to be small, with a root-mean-square difference of around 2.4%. It was found that the discrete ordinates method, with a higher order of Legendre polynomial expansions, underestimated the absorbed dose near the center of the phantom (i.e., low dose region). Simulations of the quadrature set 8 and the first order of the Legendre polynomial expansions proved to be the most efficient computation method in the authors’ study. The single-thread computation time of the deterministic simulation of the quadrature set 8 and the first order of the Legendre polynomial expansions was 21 min on a personal computer. Conclusions: The simulation results showed that the deterministic method can be effectively used to estimate the absorbed dose in a CTDI phantom. The accuracy of the discrete ordinates method was close to that of a Monte Carlo simulation, and the primary benefit of the discrete ordinates method lies in its rapid computation speed. It is expected that further optimization of this method in routine clinical CT dose estimation will improve its accuracy and speed.

07 ISOTOPE AND RADIATION SOURCES↗

SU-C-303-02: Correlating Metabolic Response to Radiation Therapy with HIF-1alpha Expression

Purpose: To understand radiation induced alterations in cellular metabolism which could be used to assess treatment or normal tissue response to aid in patient-specific adaptive radiotherapy. This work aims to compare the metabolic response of two head and neck cell lines, one malignant (UM-SCC-22B) and one benign (Normal Oral Keratinocyte), to ionizing radiation. Responses are compared to alterations in HIF-1alpha expression. These dynamics can potentially serve as biomarkers in assessing treatment response allowing for patient-specific adaptive radiotherapy. Methods: Measurements of metabolism and HIF-1alpha expression were taken before and X minutes after a 10 Gy dose of radiation delivered via an orthovoltage x-ray source. In vitro changes in metabolic activity were measured via fluorescence lifetime imaging (FLIM) to assess the mean lifetime of NADH autofluorescence following a dose of 10 Gy. HIF-1alpha expression was measured via immunohistochemical staining of in vitro treated cells and expression was quantified using the FIJI software package. Results: FLIM demonstrated a decrease in the mean fluorescence lifetime of NADH by 100 ps following 10 Gy indicating a shift towards glycolytic pathways for malignant cells; whereas this benign cell line showed little change in metabolic signature. Immunohistochemical analysis showed significant changes in HIF-1alpha expression in response to 10 Gy of radiation that correlate to metabolic profiles. Conclusion: Radiation induces significant changes in metabolic activity and HIF-1alpha expression. These alterations occur on time scales approximating the duration of common radiation treatments (approximately tens of minutes). Further understanding these dynamics has important implications with regard to improvement of therapy and biomarkers of treatment response.

60 APPLIED LIFE SCIENCES↗

SU-E-E-02: An Excel-Based Study Tool for ABR-Style Exams

Purpose: As the landscape of learning and testing shifts toward a computer-based environment, a replacement for paper-based methods of studying is desirable. Using Microsoft Excel, a study tool was developed that allows the user to populate multiple-choice questions and then generate an interactive quiz session to answer them. Methods: The code for the tool was written using Microsoft Excel Visual Basic for Applications with the intent that this tool could be implemented by any institution with Excel. The base tool is a template with a setup macro, which builds out the structure based on user’s input. Once the framework is built, the user can input sets of multiple-choice questions, answer choices, and even add figures. The tool can be run in random-question or sequential-question mode for single or multiple courses of study. The interactive session allows the user to select answer choices and immediate feedback is provided. Once the user is finished studying, the tool records the day’s progress by reporting progress statistics useful for trending. Results: Six doctoral students at UTHSCSA have used this tool for the past two months to study for their qualifying exam, which is similar in format and content to the American Board of Radiology (ABR) Therapeutic Part II exam. The students collaborated to create a repository of questions, met weekly to go over these questions, and then used the tool to prepare for their exam. Conclusion: The study tool has provided an effective and efficient way for students to collaborate and be held accountable for exam preparation. The ease of use and familiarity of Excel are important factors for the tool’s use. There are software packages to create similar question banks, but this study tool has no additional cost for those that already have Excel. The study tool will be made openly available.

97 MATHEMATICS AND COMPUTING↗

SU-E-E-15: Design of a Water Calorimeter for Dual Use in An Integrated MRI-Linac and Gamma-Knife

Purpose: To design a water calorimeter for dual use in an integrated MRI-linac and Gamma-Knife. In calorimetry, dose to water is measured based on the assumption that energy absorbed in a sensitive volume is completely converted to temperature rise {sub (}ΔΤ{sub )} according to the specific heat capacity of the medium c: D=c*ΔT*k, where k is heat transfer correction factor and compensates for heat gain or loss at point of measurement due to conductive effects. Methods: A commercial finite element method software package was used to model four different water calorimeter designs. The long term (48 h) thermal stability of each design was accurately modeled, and the optimization of the final design was based on evaluation of the standard deviation of k for ten consecutive irradiation runs (lower standard deviation translates to greater thermal stability). Several insulator materials of varying thicknesses were investigated, and a sensitivity study of thermal stability to variations in ambient temperature fluctuations was undertaken. Specifically, we evaluated the effect of possible variations in coolant temperature circulating around the calorimeter tank in several scenarios (constant, slowly increasing, or fluctuating). Results: Due to MRI-compatibility requirements, the calorimeter is to be built entirely out of plastic. Among all insulation materials tested, solid state aerogel-based insulation resulted in least heat loss and thermal stability. The final design is cylindrical on top (to be used upright in MRI-linac) and semi-spherical at bottom (for use in GammaKnife). The range of k was found to be 1.002 ± 0.013 (k = 1), comparable with a k of 1.002 ± 0.014 for typical water calorimeters used in high energy beams. A long term stability of 0.36 µK/hr was evaluated. Conclusion: Optimization of a water calorimeter design for dual use in MRI-linac and Gamma-Knife has been completed and the device is currently in production. Supported by NSERC RGPIN 435608.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-P-22: AAPM Task Group 263 Tackling Standardization of Nomenclature for Radiation Therapy

Purpose: There is growing recognition of need for increased clarity and consistency in the nomenclatures used for body and organ structures, DVH metrics, toxicity, dose and volume units, etc. Standardization has multiple benefits; e.g. facilitating data collection for clinical trials, enabling the pooling of data between institutions, making transfers (i.e. hand-offs) between centers safer, and enabling vendors to define “default” settings. Towards this goal, the American Association of Physicists in Medicine (AAPM) formed a task group (TG263) in July of 2014, operating under the Work Group on Clinical Trials to develop consensus statements. Guiding principles derived from the investigation and example nomenclatures will be presented for public feedback. Methods: We formed a multi-institutional and multi-vendor collaborative group of 39 physicists, physicians and others involved in clinical use and electronic transfer of information. Members include individuals from IROC, NRG, IHE-RO, DICOM WG-7, ASTRO and EORTC groups with overlapping interests to maximize the quality of the consensus and increase the likelihood of adoption. Surveys of group and NRG members were used to define current nomenclatures and requirements. Technical requirements of vendor systems and the proposed DICOM standards were examined. Results: There is a marked degree of inter and intra institutional variation in current approaches, resulting from inter-vendor differences in capabilities, clinic specific conceptualizations and inconsistencies. Using a consensus approach, the group defined optimal formats for the naming of targets and normal structures. A formal objective assessment of 13 existing clinically-used software packages show that all had capabilities to accommodate these recommended nomenclatures. Conclusions: A multi-stakeholder effort is making significant steps forward in developing a standard nomenclature that will work across platforms. Our current working list includes > 550 structures. Outreach efforts are ongoing to ensure broader participation in evaluating and testing the principles as they are developed by TG263.

60 APPLIED LIFE SCIENCES↗

SU-E-J-86: Functional Conformal Planning for Stereotactic Body Radiation Therapy with CT-Pulmonary Ventilation Imaging

Purpose: To evaluate the functional planning using CT-pulmonary ventilation imaging for conformal SBRT. Methods: The CT-pulmonary ventilation image was generated using the Jacobian metric in the in-house program with the NiftyReg software package. Using the ventilation image, the normal lung was split into three lung regions for functionality (high, moderate and low). The anatomical plan (AP) and functional plan (FP) were made for ten lung SBRT patients. For the AP, the beam angles were optimized with the dose-volume constraints for the normal lung sparing and the PTV coverage. For the FP, the gantry angles were also optimized with the additional constraint for high functional lung. The MLC aperture shapes were adjusted to the PTV with the additional 5 mm margin. The dosimetric parameters for PTV, the functional volumes, spinal cord and so on were compared in both plans. Results: Compared to the AP, the FP showed better dose sparing for high- and moderate-functional lungs with similar PTV coverage while not taking care of the low functional lung (High:−12.9±9.26% Moderate: −2.0±7.09%, Low: +4.1±12.2%). For the other normal organs, the FP and AP showed similar dose sparing in the eight patients. However, the FP showed that the maximum doses for spinal cord were increased with the significant increment of 16.4Gy and 21.0Gy in other two patients, respectively. Because the beam direction optimizer chose the unexpected directions passing through the spinal cord. Conclusion: Even the functional conformal SBRT can selectively reduce high- and moderatefunctional lung while keeping the PTV coverage. However, it would be careful that the optimizer would choose unexpected beam angles and the dose sparing for the other normal organs can be worse. Therefore, the planner needs to control the dose-volume constraints and also limit the beam angles in order to achieve the expected dose sparing and coverage.

60 APPLIED LIFE SCIENCES↗

SU-E-J-102: Performance Variations Among Clinically Available Deformable Image Registration Tools in Adaptive Radiotherapy: How Should We Evaluate and Interpret the Result?

Purpose: To evaluate the performance variations in commercial deformable image registration (DIR) tools for adaptive radiation therapy. Methods: Representative plans from three different anatomical sites, prostate, head-and-neck (HN) and cranial spinal irradiation (CSI) with L-spine boost, were included. Computerized deformed CT images were first generated using virtual DIR QA software (ImSimQA) for each case. The corresponding transformations served as the “reference”. Three commercial software packages MIMVista v5.5 and MIMMaestro v6.0, VelocityAI v2.6.2, and OnQ rts v2.1.15 were tested. The warped contours and doses were compared with the “reference” and among each other. Results: The performance in transferring contours was comparable among all three tools with an average DICE coefficient of 0.81 for all the organs. However, the performance of dose warping accuracy appeared to rely on the evaluation end points. Volume based DVH comparisons were not sensitive enough to illustrate all the detailed variations while isodose assessment on a slice-by-slice basis could be tedious. Point-based evaluation was over-sensitive by having up to 30% hot/cold-spot differences. If adapting the 3mm/3% gamma analysis into the evaluation of dose warping, all three algorithms presented a reasonable level of equivalency. One algorithm had over 10% of the voxels not meeting this criterion for the HN case while another showed disagreement for the CSI case. Conclusion: Overall, our results demonstrated that evaluation based only on the performance of contour transformation could not guarantee the accuracy in dose warping. However, the performance of dose warping accuracy relied on the evaluation methodologies. Nevertheless, as more DIR tools are available for clinical use, the performance could vary at certain degrees. A standard quality assurance criterion with clinical meaning should be established for DIR QA, similar to the gamma index concept, in the near future.

60 APPLIED LIFE SCIENCES↗

SU-E-T-507: Internal Dosimetry in Nuclear Medicine Using GATE and XCAT Phantom: A Simulation Study

Purpose Monte Carlo simulations are routinely used for internal dosimetry studies. These studies are conducted with humanoid phantoms such as the XCAT phantom. In this abstract we present the absorbed doses for various pairs of source and target organs using three common radiotracers in nuclear medicine. Methods The GATE software package is used for the Monte Carlo simulations. A typical female XCAT phantom is used as the input. Three radiotracers 153Sm, 131I and 99mTc are studied. The Specific Absorbed Fraction (SAF) for gamma rays (99mTc, 153Sm and 131I) and Specific Fraction (SF) for beta particles (153Sm and 131I) are calculated for all 100 pairs of source target organs including brain, liver, lung, pancreas, kidney, adrenal, spleen, rib bone, bladder and ovaries. Results The source organs themselves gain the highest absorbed dose as compared to other organs. The dose is found to be inversely proportional to distance from the source organ. In SAF results of 153Sm, when the source organ is lung, the rib bone, gain 0.0730 (Kg-1) that is more than lung itself. Conclusion The absorbed dose for various organs was studied in terms of SAF and SF. Such studies hold importance for future therapeutic procedures and optimization of induced radiotracer.

60 APPLIED LIFE SCIENCES↗

SU-E-T-536: LINAC-Based Single Isocenter Frameless SRT for Brain Metastases

Purpose: Single-isocenter Stereotactic Radiotherapy of multiple brain metastases with Varian 21 IX LINAC, using Aktina Pinpoint system for patient setup. Methods: In 2014, five single-isocenter RapidArc SRT plans were delivered to five patients with 2 to 8 brain metastases using Varian 21 IX. Aktina Pinpoint system was used for setup and 2mm PTV margin were used. CBCT was acquired before and after the beam delivery. The prescription is 2100 cGy in 3 fractions. Eclipse planning system was used for treatment planning. Depending on the number of metastases and their locations, 1 to 5 coplanar or non coplanar arcs were used. Typically, 2 or 3 arcs are used. IMRT QAs were performed by comparing an A1SL ion chamber point dose measurement in solid water phantom to point dose of the plan; also, based on EPID measurement, 3D spatial dose was calculated using DosimetryCheck software package from MathResolutions Inc. The EPID system has an active area of 40cm by 30cm with 1024 by 768 photodiodes, which corresponds to a resolution of 0.4mm by 0.4mm pixel dimension. Results: for all the plans, at least 95% PTV coverage was achieved for full prescription dose, with plan normalization > 75%. RTOG conformity indices are less than 1.1 and Paddick gradient indices are less than 4.5. The distance from prescription IDL to 50% IDL increases as the number of metastases increases, and it ranges from 0.6mm to 0.8mm. Treatment time varies from 10mins to 30mins, depending on the number of arcs and if the arcs are coplanar. IMRT QA shows that the ion chamber measurement agree with the eclipse calculation within 3%, and 95% of the points passed Gamma, using 3% dose difference and 3mm DTA Conclusion: High quality single isocenter RapidArc SRT plan can be optimized and accurately delivered using Eclipse and Varian 21IX.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-557: Monte Carlo Modeling of Philips RT-250 Orthovoltage Unit for Beam Spectrum Modulation

Purpose: To develop and validate a Monte Carlo (MC) model of a Phillips RT-250 orthovoltage unit to test various beam spectrum modulation strategies for in vitro/vivo studies. A model of this type would enable the production of unconventional beams from a typical orthovoltage unit for novel therapeutic applications such as gold nanoparticle-aided radiotherapy. Methods: The MCNP5 code system was used to create a MC model of the head of RT-250 and a 30 × 30 × 30 cm{sup 3} water phantom. For the x-ray machine head, the current model includes the vacuum region, beryllium window, collimators, inherent filters and exterior steel housing. For increased computational efficiency, the primary x-ray spectrum from the target was calculated from a well-validated analytical software package. Calculated percentage-depth-dose (PDD) values and photon spectra were validated against experimental data from film and Compton-scatter spectrum measurements. Results: The model was validated for three common settings of the machine namely, 250 kVp (0.25 mm Cu), 125 kVp (2 mm Al), and 75 kVp (2 mm Al). The MC results for the PDD curves were compared with film measurements and showed good agreement for all depths with a maximum difference of 4 % around dmax and under 2.5 % for all other depths. The primary photon spectra were also measured and compared with the MC results showing reasonable agreement between the two, validating the input spectra and the final spectra as predicted by the current MC model. Conclusion: The current MC model accurately predicted the dosimetric and spectral characteristics of each beam from the RT-250 orthovoltage unit, demonstrating its applicability and reliability for beam spectrum modulation tasks. It accomplished this without the need to model the bremsstrahlung xray production from the target, while significantly improved on computational efficiency by at least two orders of magnitude. Supported by DOD/PCRP grant W81XWH-12-1-0198.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TU-G-204-06: Correlation Between Texture Analysis-Based Model Observer and Human Observer in Diagnosis of Ischemic Infarct in Non-Contrast Head CT of Adults

Purpose: To investigate the correlation between texture analysis-based model observer and human observer in the task of diagnosis of ischemic infarct in non-contrast head CT of adults. Methods: Non-contrast head CTs of five patients (2 M, 3 F; 58–83 y) with ischemic infarcts were retro-reconstructed using FBP and Adaptive Statistical Iterative Reconstruction (ASIR) of various levels (10–100%). Six neuro -radiologists reviewed each image and scored image quality for diagnosing acute infarcts by a 9-point Likert scale in a blinded test. These scores were averaged across the observers to produce the average human observer responses. The chief neuro-radiologist placed multiple ROIs over the infarcts. These ROIs were entered into a texture analysis software package. Forty-two features per image, including 11 GLRL, 5 GLCM, 4 GLGM, 9 Laws, and 13 2-D features, were computed and averaged over the images per dataset. The Fisher-coefficient (ratio of between-class variance to in-class variance) was calculated for each feature to identify the most discriminating features from each matrix that separate the different confidence scores most efficiently. The 15 features with the highest Fisher -coefficient were entered into linear multivariate regression for iterative modeling. Results: Multivariate regression analysis resulted in the best prediction model of the confidence scores after three iterations (df=11, F=11.7, p-value<0.0001). The model predicted scores and human observers were highly correlated (R=0.88, R-sq=0.77). The root-mean-square and maximal residual were 0.21 and 0.44, respectively. The residual scatter plot appeared random, symmetric, and unbiased. Conclusion: For diagnosis of ischemic infarct in non-contrast head CT in adults, the predicted image quality scores from texture analysis-based model observer was highly correlated with that of human observers for various noise levels. Texture-based model observer can characterize image quality of low contrast, subtle texture changes in addition to human observers.

60 APPLIED LIFE SCIENCES↗

TU-F-CAMPUS-J-03: Elasticity Functions Based On 4DCT Images to Predict Tumor and Normal Tissue Response to Radiation for Patients with Lung Cancers

Purpose: To investigate radiotherapy outcomes by incorporating 4DCT-based physiological and tumor elasticity functions for lung cancer patients. Methods: 4DCT images were acquired from 28 lung SBRT patients before radiation treatment. Deformable image registration (DIR) was performed from the end-inhale to the end-exhale using a B-Spline-based algorithm (Elastix, an open source software package). The resultant displacement vector fields (DVFs) were used to calculate a relative Jacobian function (RV) for each patient. The computed functions in the lung and tumor regions represent lung ventilation and tumor elasticity properties, respectively. The 28 patients were divided into two groups: 16 with two-year tumor local control (LC) and 12 with local failure (LF). The ventilation and elasticity related RV functions were calculated for each of these patients. Results: The LF patients have larger RV values than the LC patients. The mean RV value in the lung region was 1.15 (±0.67) for the LF patients, higher than 1.06 (±0.59) for the LC patients. In the tumor region, the elasticity-related RV values are 1.2 (±0.97) and 0.86 (±0.64) for the LF and LC patients, respectively. Among the 16 LC patients, 3 have the mean RV values greater than 1.0 in the tumors. These tumors were located near the diaphragm, where the displacements are relatively large.. RV functions calculated in the tumor were better correlated with treatment outcomes than those calculated in the lung. Conclusion: The ventilation and elasticity-related RV functions in the lung and tumor regions were calculated from 4DCT image and the resultant values showed differences between the LC and LF patients. Further investigation of the impact of the displacements on the computed RV is warranted. Results suggest that the RV images might be useful for evaluation of treatment outcome for lung cancer patients.

60 APPLIED LIFE SCIENCES↗