Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerator Control System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Foundational Science to Accelerate Nuclear Energy Innovation [Brochure]

The foundational science gaps inhibiting the advancement of nuclear energy technologies are identified and tackled in five priority research opportunities. These opportunities pave the way to accelerate the development and ultimately the adoption of new nuclear energy systems. They include the fundamental aspects of ion-electron interactions; novel properties of next-generation coolants and solvents; interfacial dynamics, not only in solids, but in other aspects of nuclear reactors; novel operando and in-situ monitoring and sensing; and artificial intelligence to accelerate condensed phases discovery. Building on the foundation established by previous BES workshops, these opportunities encompass recent advances in fundamental knowledge and focus on the experimental and computational methods needed to resolve major technical challenges for nuclear energy technologies. Through developing fundamental scientific insight as well as pushing the frontiers of modeling complex systems and probing the operation of materials and chemical systems in extreme environments, research motivated by the priorities identified here will further develop the promise, potential, and utilization of nuclear energy for a clean energy future. The PROs are as follows: (1) Master complex electronic structures to tailor thermochemical reactivity, transport, and microstructural evolution; (2) Interrogate and direct the physics and chemistry underpinning next-generation coolants and solvents; (3) Elucidate and control the underlying physics and chemistry of interfaces in complex nuclear environments; (4) Bridge multi-fidelity multi-resolution experiments, computational modeling, and data science to control dynamic behavior; and (5) Harness artificial intelligence to design inherently resilient condensed phases.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Status of NIO1 construction

The NIO1 (Negative Ion Optimization phase 1) project consists of a multiaperture negative ion source mounted on a 60 kV accelerating column; up to 9 beamlets (15 mA H{sup -} each one) arranged in 3x3 matrix with 14 mm spacing can be extracted. The moderate size and the modular concept make some relative rotation of the source magnetic filter and the electrodes possible, so that the effect of crossed and aligned field can be easily compared. Other goals of source experimental program are emittance (and beam profile) measurement at several distances (for simulation code validation), testing of diagnostic components and of radiofrequency coupling. A full set of construction drawing was completed; also the Fast Emittance Scanner (FES) and its vacuum chambers were built (four mounting positions are reserved to FES). Some low power rf matching boxes were developed for a test plasma, approximately half the source size. A cesium oven compatible with NIO1 is being also developed; by using some industrial standard 100 W heaters (with a proper driver) a careful control of temperature is planned.

43 PARTICLE ACCELERATORS↗

Robust RF Photocathodes (Phase II Final Report)

This program addressed requirements for photocathodes with high quantum efficiency (QE) and long lifetimes. Currently, photocathodes with QEs above 1% exhibit lifetimes measured in a few hours. This is unacceptable for commercial devices using photocathodes as the electron source. This includes accelerators for industrial, medical, defense, and educational applications as well as emerging applications, such as time resolved electron microscopy. Calabazas Creek Research, Inc. (CCR) and the University of Maryland (UMD) attempted to develop reservoir photocathodes that dramatically increased lifetime and increased the ability to recover from contaminating events, such as loss of system vacuum. The Phase I program demonstrated the viability of the reservoir approach for higher QE cathodes. The Phase II program focused on design, fabrication, and delivery. This included increasing understanding of photocathode physics, investigating design options, addressing performance issues, and developing fabrication and packaging techniques leading to commercial products. The initial task identified specific photocathode materials that provide high QE and are compatible with the reservoir approach. The goal was that these photocathodes be manufacturable in a production environment, understanding that the “environment” is highly specialized. The photocathode geometry was modified to address several photogun performance issues related primarily to emittance. A goal was to reduce or eliminate thermal emittance issues arising from the reservoir heater. The program developed fabrication, handling, and transport techniques and facilities to allow commercial photocathode production for certain materials. Not only was complex chemistry involved, but practical issues of transporting and installing the cathodes into user systems were addressed. A critical goal was demonstration of reservoir photocathodes in operating RF guns, where performance could be directly measured. Success depended on clear demonstration that the cathodes could be produced, delivered, installed, and provide the required performance. The principal effort in this program was to develop reservoir cesium antimonide photocathodes. Cesium antimonide cathodes provide a work function in excess of the 1% goal, while the current generation exhibits lifetimes measured in hours. The reservoir in CCRs’ controlled porosity reservoir (CPR) cathodes provides a mechanism for replacing cesium evaporating from the surface by transporting replacement cesium from the reservoir. This is accomplished by gently heating the reservoir to induce cesium diffusion through micron-scale pores in the reservoir cap and photocathode emitter. Experiments at the UMD determined that cesium diffused from the reservoir would only react with antimony on the surface if the temperature exceeded 300C. At this temperature, however, the surface cesium evaporated faster than it could be replenished from the reservoir. Consequently, the QE decreased each time recessiation was attempted. This appears to be a fundamental problem with this approach. The sections below provide information on accomplishments for each task in the program. Once the issue with cesium antimonide cathodes was identified, CCR refocused the program to begin investigation of graphene coated photocathodes in collaboration with SLAC National Accelerator Laboratory (SLAC). The photocathode test chamber developed in the program was transferred to SLAC for use in the graphene research. This is described below in a task added to the program.

43 PARTICLE ACCELERATORS↗

SU-E-T-599: Patient Safety Enhancements Through a Study of R&V System Override Data

Purpose: Record and verify (R&V) software systems include safety checks that compare actual machine parameters with prescribed values for a patient’s treatment, such as treatment couch position, linac, energy, and MUs. The therapist is warned of a mismatch with a pop-up and prompted to approve an override in order to continue without changes. Override approval is often legitimate, but the pop-up can also genuinely indicate a problem that would Result in the wrong treatment. When there are numerous pop-up warnings, human nature leads us to approve any override without careful reading, undermining the effectiveness of the safety mechanism. Methods: Override data was collected from our R&V system for all patients treated between October 8 and 29, 2012, on four linacs and entered into a spreadsheet. Additional data collected included treatment technique, disease site, immobilization, time, linac, and whether localization images were obtained. Data were analyzed using spreadsheet tools to reveal trends, patterns and associations that might suggest appropriate process changes that could decrease the total number of overrides. Results: 76 out of 113 patients had overrides. Out of the 944 treatments, 599 override items were generated. The majority were due to couch positions. 74 of the 84 overrides on a linac equipped with a 6D couch were due to the use of the rotational corrections and the fact that the 6D couch control does not communicate with the R&V system; translations required to rotate the couch appear to the R&V system as translations outside the tolerance range. Conclusion: Many findings were interesting but did not suggest a process change. Proposed process changes include creating site-specific instead of just technique-specific tolerance tables for couch shifts. Proposed improvements to the vendor are to facilitate direct communication between the 6D couch and the R&V system to eliminate those override warnings related to lack of communication.

61 RADIATION PROTECTION AND DOSIMETRY↗

Energetic Control of Redox-Active Polymers toward Safe Organic Bioelectronic Materials

Avoiding faradaic side reactions during the operation of electrochemical devices is important to enhance the device stability, to achieve low power consumption, and to prevent the formation of reactive side-products. This is particularly important for bioelectronic devices, which are designed to operate in biological systems. While redox-active materials based on conducting and semiconducting polymers represent an exciting class of materials for bioelectronic devices, they are susceptible to electrochemical side-reactions with molecular oxygen during device operation. In this work, electrochemical side reactions with molecular oxygen are shown to occur during organic electrochemical transistor (OECT) operation using high-performance, state-of-the-art OECT materials. Depending on the choice of the active material, such reactions yield hydrogen peroxide (H 2 O 2 ), a reactive side-product, which may be harmful to the local biological environment and may also accelerate device degradation. A design strategy is reported for the development of redox-active organic semiconductors based on donor–acceptor copolymers that prevents the formation of H 2 O 2 during device operation. This study elucidates the previously overlooked side-reactions between redox-active conjugated polymers and molecular oxygen in electrochemical devices for bioelectronics, which is critical for the operation of electrolyte-gated devices in application-relevant environments.

36 MATERIALS SCIENCE↗

Achievement in Beam Power Records for the NOvA Target System

We began upgrading the NOvA target system for 1-Mega Watt (1-MW) beam operation in 2017. Major challenges included maintaining the quality of neutrino beams with reliable instrumentation, reducing instantaneous beam heating on the target, increasing cooling power to handle the high-power beam, and controlling tritium water production rate. We finally achieved a one-hour beam power record of 1.018 MW in Summer 2024. This milestone demonstrates our capability to operate at 2+ MW beam power for the future Long Baseline Neutrino Facility (LBNF) and Deep Underground Neutrino Experiment (DUNE).

43 PARTICLE ACCELERATORS↗

Rotating-Coil Measurement System for Small-Bore-Diameter Magnet Characterization

Rotating-coil measurement systems are widely used to measure the multipolar fields of particle accelerator magnets. This paper presents a rotating-coil measurement system that aims at providing a complete data set for the characterization of quadrupole magnets with small bore diameters (26 mm). The PCB magnetometer design represents a challenging goal for this type of transducer. It is characterized by an aspect ratio 30% higher than the state of the art, imposed by the reduced dimension of the external radius of the rotating shaft and the necessity of covering the entire magnet effective length (500 mm or higher). The system design required a novel design for the mechanical asset, also considering the innovation represented by the commercial carbon fiber tube, housing the PCB magnetometer. Moreover, the measurement system is based primarily on standard and commercially available components, with simplified control and post-processing software applications. The system and its components are cross-calibrated using a stretched-wire system and another rotating-coil system. The measurement precision is established in a measurement campaign performed on a quadrupole magnet characterized by an inner bore diameter of 45 mm.

42 ENGINEERING↗

IGBT Gate Driver Upgrades to the HVCM at the SNS

The SNS at ORNL has been fully operational since 2006 and in September 2009, the design goal of 1MW of sustained beam power on target was achieved. Historically, the high voltage converter modulators (HVCM) have been a known problem area and, in order to reach another SNS milestone of 90% availability, a new gate driver was one of several areas targeted to improve the overall reliability of the HVCM systems. The drive capability and fault protection of the large IGBT modules in the HVCM were specifically addressed to improve IGBT switching characteristics and provide enhanced troubleshooting and monitoring capabilities for the critical IGBT/driver pair. This paper outlines the work involved; the result obtained and documents the driver s long-term performance. Enhanced features, designed to be used in conjunction with a new controller presently under development, will also be discussed.

IGBT gate driver↗

Electron Lenses and Cooling for the Fermilab Integrable Optics Test Accelerator

Recently, the study of integrable Hamiltonian systems has led to nonlinear accelerator lattices with one or two transverse invariants and wide stable tune spreads. These lattices may drastically improve the performance of high-intensity machines, providing Landau damping to protect the beam from instabilities, while preserving dynamic aperture. The Integrable Optics Test Accelerator (IOTA) is being built at Fermilab to study these concepts with 150-MeV pencil electron beams (single-particle dynamics) and 2.5-MeV protons (dynamics with self fields). One way to obtain a nonlinear integrable lattice is by using the fields generated by a magnetically confined electron beam (electron lens) overlapping with the circulating beam. The required parameters are similar to the ones of existing devices. In addition, the electron lens will be used in cooling mode to control the brightness of the proton beam and to measure transverse profiles through recombination. More generally, it is of great interest to investigate whether nonlinear integrable optics allows electron coolers to exceed limitations set by both coherent or incoherent instabilities excited by space charge.

43 PARTICLE ACCELERATORS↗

2011 Mound Site Groundwater Plume Rebound Exercise and Follow-Up - 13440

The Mound Site facility near Miamisburg, Ohio, opened in 1948 to support early atomic weapons programs. It grew into a research, development, and production facility performing work in support of the U.S. Department of Energy (DOE) weapons and energy programs. The plant was in operation until 1995. During the course of operation, an onsite landfill was created. The landfill was located over a finger of a buried valley aquifer, which is a sole drinking water source for much of the Miami Valley. In the 1980's, volatile organic compounds (VOCs) were discovered in groundwater at the Mound site. The site was placed on the National Priorities List on November 21, 1989. DOE signed a Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) Federal Facility Agreement with the U.S. Environmental Protection Agency (EPA) and the Ohio Environmental Protection Agency. The agreement became effective in October 1990. The area that included the landfill was designated Operational Unit 1 (OU-1). In 1995, a Record of Decision was signed that called for the installation and operation of a pump and treatment (P and T) system in order to prevent the VOCs in OU-1 groundwater from being captured by the onsite water production wells. In addition to the P and T system, a soil vapor extraction (SVE) system was installed in 1997 to accelerate removal of VOCs from groundwater in the OU-1 area. The SVE system was successful in removing large amounts of VOCs and continued to operate until 2007, when the amount of VOCs removed became minimal. A rebound study was started in February 2003 to determine how the groundwater system and contaminants would respond to shutting down the P and T system. The rebound test was stopped in February 2004 because predetermined VOC threshold concentrations were exceeded down-gradient of the landfill. The P and T and SVE systems were restarted after the termination of the rebound test. In 2006, the remediation of the Mound site was completed and the site was declared to be protective of human health and the environment, as long as the institutional controls are observed. The institutional controls that apply to the OU-1 area include provisions that no soil be allowed to leave the site, no wells be installed for drinking water, and the site may be approved only for industrial use. The onsite landfill with the operating CERCLA remedy remained. However, the Mound Development Corporation lobbied Congress for funds to remediate the remaining onsite landfill to allow for property reuse. In 2007 DOE received funding from Congress to perform non-CERCLA removal actions at OU-1 to excavate the site sanitary landfill. In 2009, DOE received American Recovery and Reinvestment Act funding to complete the project. Excavation of the landfill occurred intermittently from 2006 through 2010 and the majority of the VOC source was removed; however, VOC levels near the P and T system remained greater than the EPA maximum contaminant levels (MCLs). Presently, groundwater is contained using two extraction wells to create a hydraulic barrier to prevent down-gradient migration of VOC-impacted groundwater. Since the primary contamination source has been removed, the feasibility of moving away from containment to a more passive remedy, namely monitored natural attenuation (MNA), is being considered. A second rebound study was started in June 2011. If contaminant and groundwater behavior met specific conditions during the study, MNA would be evaluated and considered as a viable alternative for the groundwater in the OU-1 area. From June through December 2011, the second rebound study evaluated the changes in VOC concentrations in groundwater when the P and T system was not in operation. As the study progressed, elevated concentrations of VOCs that exceeded predetermined trigger values were measured along the down-gradient boundary of the study area, and so the P and T system was restarted. It was determined that a discrete area with VOC concentrations greater than the MCLs was present in groundwater down-gradient of the extraction wells. The source was not identified, but the contamination was thought not to be caused by residually contaminated soil beneath the former landfill. The data collected so far supports the consideration of MNA as a viable alternative to hydraulic containment. Additional investigations are being performed to identify possible sources or pathways of VOCs in groundwater that may be contributing to the elevated VOC levels measured down-gradient of the extraction well system. Data from this additional investigation will be used to determine whether the VOCs detected down-gradient of the hydraulic boundary are the result of residual soil contamination, a previously unknown contribution of VOC-contaminated water entering the groundwater outside the capture zone of the extraction wells, or a pulse of VOC-contaminated groundwater from the OU-1 landfill that occurred during the rebound study. (authors)

54 ENVIRONMENTAL SCIENCES↗

Particulate Emissions Control using Advanced Filter Systems: Final Report for Argonne National Laboratory, Corning Inc. and Hyundai Motor Company CRADA Project

This is a 3-way CRADA project working together with Corning, Inc. and Hyundai Motor Co. (HMC). The project is to understand particulate emissions from gasoline direct-injection engines (GDI) and their physico-chemical properties. In addition, this project focuses on providing fundamental information about filtration and regeneration mechanisms occurring in gasoline particulate filter (GPF) systems. For the work, Corning provides most advanced filter substrates for GPF applications and HMC provides three-way catalyst (TWC) coating services of these filter by way of a catalyst coating company. Then, Argonne National Laboratory characterizes fundamental behaviors of filtration and regeneration processes as well as evaluated TWC functionality for the coated filters. To examine aging impacts on TWC and GPF performance, the research team evaluates gaseous and particulate emissions as well as back-pressure increase with ash loading by using an engine-oil injection system to accelerate ash loading in TWC-coated GPFs.

42 ENGINEERING↗

New Fast Kicker Results from the Muon g-2 E-989 Experiment at Fermilab

We describe the installation, commissioning, and char-acterization of the injection kicker system for the E-989 experiment at Fermilab for a precision measurement of the muon anomalous magnetic moment. Control and monitoring systems have been implemented to acquire and record the waveforms of each kicker pulse, and measurements of various kicker system observables were recorded in the presence of the 1.45 T g-2 storage ring magnetic field. These monitoring systems are necessary to understand the systematic contribution to the measure-ment of the precession frequency. We examine the dependence of muon capture to kicker field predictions.

43 PARTICLE ACCELERATORS↗

New Advances in Optical Stochastic Cooling

Recently, Optical Stochastic Cooling (OSC) became the first demonstrated method for ultra-high-bandwidth stochastic cooling. The initial experiments at Fermilab’s IOTA ring explored the essential physics of the method and demonstrated cooling, heating and manipulation of beams and single particles. Having been validated in practice, with continued development, OSC carries the potential for dramatic advances in the state-of-the-art performance and flexibility for beam cooling and control. The ongoing program at Fermilab is now focused on the development of an OSC system that includes high-gain optical amplification, which promises a two-order-of-magnitude increase in the strength of the OSC force. In this talk, we briefly review the results of the initial experimental campaign, describe the status of the conceptual and hardware designs for the amplified OSC system, report initial experimental results of our high-gain amplifier development, and explore near-term operational plans and use cases.

43 PARTICLE ACCELERATORS↗

Helium recovery system at IB3a

The increasing need for optimal and sustainable use of cryogenic resources to support Fermilab’s scientific mission has highlighted the necessity of improving the Laboratory’s helium management practices. An assessment of cryogenic test facilities identified the Technical Division’s Industrial Building 3a (IB3A) as a key site requiring upgrades to integrate a helium recovery system. The IB3A facility is essential for characterizing and testing superconductors, cables, and coils for various R&D projects, including the US High-Luminosity LHC Accelerator Upgrade Project (AUP), Mu2e, and other external collaborations. Currently, the facility relies on 500 L helium Dewars and vents the vaporized helium directly into the atmosphere, leading to significant helium loss. Given the non-renewable nature of helium, recovering and reusing this resource is critical for the sustainability of Fermilab’s operations. To address this challenge, a project has been initiated to connect IB3A to an existing helium purification station and refrigeration system located in another building via a dedicated pipeline pass over the roof of several buildings. This solution will enable the efficient capture of vented helium, its transfer to the purification station, and subsequent liquefaction for reuse in future operations. The project includes a detailed design phase, specifying the pipeline route, flow control mechanisms, and integration with the existing cryogenic infrastructure, followed by phased implementation and commissioning. By implementing this pipeline connection and upgrading IB3A, Fermilab aims to significantly reduce helium waste, lower operational costs, and align with its commitment to sustainability. This initiative provides a model for resource-efficient cryogenic operations and reinforces the Laboratory’s capacity to support its science mission for the long term.

Porwisiak, D. [Fermilab]↗

A Program for Optimizing SRF Linac Costs

Every well-designed machine goes through the process of cost optimization several times during its design, production and operation. The initial optimizations are done during the early proposal stage of the project when none of the systems have been engineered. When a superconducting radio frequency (SRF) linac is implemented as part of the design, it is often a difficult decision as to the frequency and gradient that will be used. Frequently, such choices are made based on existing designs, which invariably necessitate moderate to substantial modifications so that they can be used in the new accelerator. Thus the fallacy of using existing designs is that they will frequently provide a higher cost machine or a machine with sub-optimal beam physics parameters. This paper describes preliminary results of a new software tool that allows one to vary parameters and understand the effects on the optimized costs of construction plus 10 year operations of an SRF linac, the associated cryogenic facility, and controls, where operations includes the cost of the electrical utilities but not the labor or other costs. It derives from collaborative work done with staff from Accelerator Science and Technology Centre, Daresbury, UK [1] several years ago while they were in the process of developing a conceptual design for the New Light Source project. The initial goal was to convert a spread sheet format to a graphical interface to allow the ability to sweep different parameter sets. The tools also allow one to compare the cost of the different facets of the machine design and operations so as to better understand the tradeoffs.

43 PARTICLE ACCELERATORS↗

Single-Fraction Stereotactic Body Radiation Therapy and Sequential Gemcitabine for the Treatment of Locally Advanced Pancreatic Cancer

Purpose: This Phase II trial evaluated the toxicity, local control, and overall survival in patients treated with sequential gemcitabine and linear accelerator-based single-fraction stereotactic body radiotherapy (SBRT). Methods and Materials: Twenty patients with locally advanced, nonmetastatic pancreatic adenocarcinoma were enrolled on this prospective single-institution, institutional review board-approved study. Gemcitabine was administered on Days 1, 8, and 15, and SBRT on Day 29. Gemcitabine was restarted on Day 43 and continued for 3-5 cycles. SBRT of 25 Gy in a single fraction was delivered to the internal target volume with a 2- 3-mm margin using a nine-field intensity-modulated radiotherapy technique. Respiratory gating was used to account for breathing motion. Follow-up evaluations occurred at 4-6 weeks, 10-12 weeks, and every 3 months after SBRT. Results: All patients completed SBRT and a median of five cycles of chemotherapy. Follow-up for the 2 remaining alive patients was 25.1 and 36.4 months. No acute Grade 3 or greater nonhematologic toxicity was observed. Late Grade 3 or greater toxicities occurred in 1 patient (5%) and consisted of a duodenal perforation (G4). Three patients (15%) developed ulcers (G2) that were medically managed. Overall, median survival was 11.8 months, with 1-year survival of 50% and 2-year survival of 20%. Using serial computed tomography, the freedom from local progression was 94% at 1 year. Conclusion: Linear accelerator-delivered SBRT with sequential gemcitabine resulted in excellent local control of locally advanced pancreatic cancer. Future studies will address strategies for reducing long-term duodenal toxicity associated with SBRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automated tabletop exfoliation and identification of monolayer graphene flakes

Over the past two decades, graphene has been intensively studied because of its remarkable mechanical, optical, and electronic properties. Initial studies were enabled by manual “Scotch Tape” exfoliation; nearly two decades later, this method is still widely used to obtain chemically pristine flakes of graphene and other 2D van der Waals materials. Unfortunately, the yield of large, pristine flakes with uniform thickness is inconsistent. Thus, significant time and effort are required to exfoliate and locate flakes suitable for fabricating multilayer van der Waals heterostructures. Here, we describe a relatively affordable tabletop device (the “eXfoliator”) that can reproducibly control key parameters and largely automate the exfoliation process. In a typical exfoliation run, the eXfoliator produces 3 or more large (≥ 400 μm 2 ) high-quality graphene monolayer flakes, allowing new users to produce such flakes at a rate comparable to manual exfoliation by an experienced user. Furthermore, we use an automated mapping system and a computer vision algorithm to locate candidate flakes. Our results provide a starting point for future research efforts to identify more precisely which parameters matter for the success of exfoliation and to optimize them.

47 OTHER INSTRUMENTATION↗