Search NASA⌕ Search

SEARCH · Search NASA

Results for “Positioning Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Supporting information for Few-Shot Learning Enables Population-Scale Analysis of Leaf Traits in Populus trichocarpa

In this work, we use few-shot learning to segment the body and vein architecture of P. trichocarpa leaves from high-resolution scans obtained in the UC Davis common garden. Leaf and vein segmentation are formulated as separate tasks, in which convolutional neural networks (CNNs) are used to iteratively expand partial segmentations until reaching stopping criteria. Our leaf and vein segmentation approaches use just 50 and 8 manually traced images for training, respectively, and are applied to a set of 2,634 top and bottom leaf scans. We show that both methods achieve high segmentation accuracy, in some cases exceeding even human-level segmentation. The leaf and vein segmentations are subsequently used to extract 68 morphological traits using traditional open-source image processing tools, which are validated using real-world physical measurements. For a biological perspective, we perform a genome-wide association study using the vein density trait to discover novel genetic architectures associated with multiple physiological processes relating to leaf development and function. In addition to sharing all of the few-shot learning code (see https://github.com/jlager/few-shot-leaf-segmentation), we are releasing all images, manual segmentations, model predictions, 68 extracted leaf phenotypes, and a new set of SNPs called against the v4 P. trichocarpa genome for 1,419 genotypes. The data folder includes all images, ground truth segmentations, predicted segmentations, and extracted leaf traits. All images encode the sample ID in the file name by indicating the treatment, block, row, position, and leaf side, respectively. For example, the file, C_1_1_2_bot.jpeg, indicates the control treatment, block 1, row 1, position 2, and the bottom side of the leaf. Tabulated results include position IDs as well as the corresponding genotype IDs. The images folder includes the 2,906 high-resolution leaf scans taken in the field. The leaf_masks folder includes 50 ground truth segmentations used for training the leaf tracing algorithm. The leaf_preds folder includes the 2,906 predicted segmentations from the leaf tracing algorithm. The vein_masks folder includes 8 ground truth segmentations used for training the vein growing algorithm. The vein_preds folder includes the 1,453 predicted segmentations from the vein growing algorithm. The vein_probs folder includes the 1,453 predicted probability maps from the vein growing algorithm before thresholding. The genomes folder includes the set of SNPs called against the v4 P. trichocarpa genome for 1,419 genotypes with a README file detailing the steps taken. The results folder includes: (i) raw values of the 68 predicted leaf traits in digital_traits.tsv, (ii) manually measured values of petiole length and width in manual_traits.tsv, (iii) thin plate spline (TPS) adjusted values of the vein density trait in vein_density_tps_adj.tsv, (iv) best linear unbiased prediction (BLUP) adjusted values of the vein density trait in vein_density_blups.tsv, and (v) GWAS results for the vein density trait, including chromosome positions and corresponding P values, in gwas_results.csv.

09 BIOMASS FUELS↗

Prospective-gated cardiac micro-CT imaging of free-breathing mice using carbon nanotube field emission x-ray

Purpose: Carbon nanotube (CNT) based field emission x-ray source technology has recently been investigated for diagnostic imaging applications because of its attractive characteristics including electronic programmability, fast switching, distributed source, and multiplexing. The purpose of this article is to demonstrate the potential of this technology for high-resolution prospective-gated cardiac micro-CT imaging. Methods: A dynamic cone-beam micro-CT scanner was constructed using a rotating gantry, a stationary mouse bed, a flat-panel detector, and a sealed CNT based microfocus x-ray source. The compact single-beam CNT x-ray source was operated at 50 KVp and 2 mA anode current with 100 {mu}mx100 {mu}m effective focal spot size. Using an intravenously administered iodinated blood-pool contrast agent, prospective cardiac and respiratory-gated micro-CT images of beating mouse hearts were obtained from ten anesthetized free-breathing mice in their natural position. Four-dimensional cardiac images were also obtained by gating the image acquisition to different phases in the cardiac cycle. Results: High-resolution CT images of beating mouse hearts were obtained at 15 ms temporal resolution and 6.2 lp/mm spatial resolution at 10% of system MTF. The images were reconstructed at 76 {mu}m isotropic voxel size. The data acquisition time for two cardiac phases was 44{+-}9 min. The CT values observed within the ventricles and the ventricle wall were 455{+-}49 and 120{+-}48 HU, respectively. The entrance dose for the acquisition of a single phase of the cardiac cycle was 0.10 Gy. Conclusions: A high-resolution dynamic micro-CT scanner was developed from a compact CNT microfocus x-ray source and its feasibility for prospective-gated cardiac micro-CT imaging of free-breathing mice under their natural position was demonstrated.

60 APPLIED LIFE SCIENCES↗

Multi-frequency SAR, SSM/I and AVHRR derived geophysical information of the marginal ice zone

A description is given of the fusion of synthetic aperture radar (SAR), special sensor microwave imager (SSM/I), and NOAA Advanced Very High Resolution Radiometer (AVHRR) data to study arctic processes. These data were collected during the SIZEX/CEAREX experiments that occurred in the Greenland Sea in March of 1989. Detailed comparisons between the SAR, AVHRR, and SSM/I indicated: (1) The ice edge position was in agreement to within 25 km, (2) The SSM/I SAR total ice concentration compared favorably, however, the SSM/I significantly underpredicted the multiyear fraction, (3) Combining high resolution SAR with SSM/I can potentially map open water and new ice features in the marginal ice zone (MIZ) which cannot be mapped by the single sensors, and (4) The combination of all three sensors provides accurate ice information as well as sea surface temperature and wind speeds.

Shuchman, R. A.↗

Apparatus to study crystal channeling and volume reflection phenomena at the SPS H8 beamline

A high performance apparatus has been designed and built by the H8-RD22 collaboration for the study of channeling and volume reflection phenomena in the interaction of 400 GeV/c protons with bent silicon crystals, during the 2006 data taking in the external beamline H8 of the CERN SPS. High-quality silicon short crystals were bent by either anticlastic or quasimosaic effects. Alignment with the highly parallel (8 {mu}rad divergence) proton beam was guaranteed through a submicroradian goniometric system equipped with both rotational and translational stages. Particle tracking was possible by a series of silicon microstrip detectors with high-resolution and a parallel plate gas chamber, triggered by various scintillating detectors located along the beamline. Experimental observation of volume reflection with 400 GeV/c protons proved true with a deflection angle of (10.4{+-}0.5) {mu}rad with respect to the unperturbed beam, with a silicon crystal whose (111) planes were parallel to the beam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Instrument for Analysis of Greenland's Glacier Mills

A new instrument is used to study the inner workings of Greenland s glacier mills by riding the currents inside a glacier s moulin. The West Greenland Moulin Explorer instrument was deployed into a tubular shaft to autonomously record temperature, pressure, 3D acceleration, and location. It is built with a slightly positive buoyancy in order to assist in recovery. The unit is made up of several components. A 3-axis MEMS (microelectromechanical systems) accelerometer with 0.001-g resolution forms the base of the unit. A pressure transducer is added that is capable of withstanding 500 psi (=3.4 MPa), and surviving down to -40 C. An Iridium modem sends out data every 10 minutes. The location is traced by a GPS (Global Positioning System) unit. This GPS unit is also used for recovery after the mission. Power is provided by a high-capacity lithium thionyl chloride D-sized battery. The accelerometer is housed inside a cylindrical, foot-long (=30 cm) polyvinyl chloride (PVC) shell sealed at each end with acrylic. The pressure transducer is attached to one of these lids and a MEMS accelerometer to the other, recording 100 samples per second per axis.

Behar, Alberto E.↗

Analysis system of submicron particle tracks in the fine-grained nuclear emulsion by a combination of hard x-ray and optical microscopy

Analyses of nuclear emulsion detectors that can detect and identify charged particles or radiation as tracks have typically utilized optical microscope systems because the targets have lengths from several μm to more than 1000 μm. For recent new nuclear emulsion detectors that can detect tracks of submicron length or less, the current readout systems are insufficient due to their poor resolution. In this study, we developed a new system and method using an optical microscope system for rough candidate selection and the hard X-ray microscope system at SPring-8 for high-precision analysis with a resolution of better than 70 nm resolution. Furthermore, we demonstrated the analysis of submicron-length tracks with a matching efficiency of more than 99% and position accuracy of better than 5 μm. This system is now running semi-automatically.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Implementation of the foil-on-hohlraum technique for the magnetic recoil spectrometer for time-resolved neutron measurements at the National Ignition Facility

The next-generation Magnetic Recoil Spectrometer, called MRSt, will provide time-resolved measurements of the deuterium-tritium-neutron spectrum from inertial confinement fusion implosions at the National Ignition Facility. These measurements will provide critical information about the time evolution of the fuel assembly, hot-spot formation, and nuclear burn. The absolute neutron spectrum in the energy range of 12-16 MeV will be measured with high accuracy (~5%), unprecedented energy resolution (~100 keV) and, for the first time ever, time resolution (~20 ps). Crucial to the design of the system is a CD conversion foil for the production of recoil deuterons positioned as close to the implosion as possible. The foil-on-hohlraum technique has been demonstrated by placing a 1-mm-diameter, 40-μm-thick CD foil on the hohlraum diagnostic band along the line-of-sight of the current time-integrated MRS system, which measured the recoil deuterons. In addition to providing validation of the foil-on-hohlraum technique for the MRSt design, substantial improvement of the MRS energy resolution was demonstrated.

42 ENGINEERING↗

The Mapping X-Ray Fluorescence Spectrometer (MAPX)

MapX will provide elemental imaging at ≤100 micron spatial resolution over 2.5 X 2.5 centimeter areas, yielding elemental chemistry at or below the scale length where many relict physical, chemical, and biological features can be imaged and interpreted in ancient rocks. MapX is a full-frame spectroscopic imager positioned on soil or regolith with touch sensors. During an analysis, an X-ray source (tube or radioisotope) bombards the sample surface with X-rays or αlpha-particles / gamma rays, resulting in sample X-ray Fluorescence (XRF). Fluoresced X-rays pass through an X-ray lens (X-ray μ-Pore Optic, "MPO") that projects a spatially resolved image of the X-rays onto a CCD. The CCD is operated in single photon counting mode so that the positions and energies of individual photons are retained. In a single analysis, several thousand frames are stored and processed. A MapX experiment provides elemental maps having a spatial resolution of ≤100 micron and quantitative XRF spectra from Regions of Interest (ROI) 2 centimers ≤ x ≤ 100 micron. ROI are compared with known rock and mineral compositions to extrapolate the data to rock types and putative mineralogies. The MapX geometry is being refined with ray-tracing simulations and with synchrotron experiments at SLAC. Source requirements are being determined through Monte Carlo modeling and experiment using XMIMSIM [1], GEANT4 [2] and PyMca [3] and a dedicated XRF test fixture. A flow-down of requirements for both tube and radioisotope sources is being developed from these experiments. In addition to Mars lander and rover missions, MapX could be used for landed science on other airless bodies (Phobos/Deimos, Comet nucleus, asteroids, the Earth's moon, and the icy satellites of the outer planets, including Europa.

Blake, David↗

A quasi-static method for determining the characteristics of a motion capture camera system in a "split-volume" configuration

The purpose of this study was to determine the accuracy, repeatability and resolution of a six-camera Motion Analysis system in a vertical split-volume configuration using a unique quasi-static methodology. The position of a reflective marker was recorded while it was moved quasi-statically over a range of 2.54 mm (0.100 inches) via a linearly-translating table. The table was placed at five different heights to cover both sub-volumes and the overlapping region. Data analysis showed that accuracy, repeatability and resolution values were consistent across all regions of the split-volume, including the overlapping section.

NASA Center JSC↗

Intrinsic energy and time resolution of the Jefferson Lab Hall C Neutral Particle Spectrometer

The Neutral Particle Spectrometer (NPS) is an advanced calorimeter designed to measure neutral electro- magnetic particles with high precision in energy, time, and position, under conditions of high luminosity and significant background. Integrated into the experimental setup of Hall C at Thomas Jefferson National Accelerator Facility, the NPS plays a critical role in studies of nucleon structure through exclusive and semi- inclusive reaction channels. Here, this paper presents an assessment of the detector’s performance characteristics, specifically its energy and timing resolution, derived from elastic electron–proton scattering data. We report an energy resolution between 1.2% and 1.3% in the 4.5–7.3 GeV range, and an intrinsic timing resolution better than 200 ps for energies above 500 MeV. These results serve as a reference for current and future precision measurements in hadronic physics.

Detector performance↗

Impact of MODIS High-Resolution Sea-Surface Temperatures on WRF Forecasts at NWS Miami, FL

Over the past few years,studies at the Short-term Prediction Research and Transition (SPoRT) Center have suggested that the use of Moderate Resolution Imaging Spectroradiometer (MODIS) composite sea-surface temperature (SST) products in regional weather forecast models can have a significant positive impact on short-term numerical weather prediction in coastal regions. The recent paper by LaCasse et al. (2007, Monthly Weather Review) highlights lower atmospheric differences in regional numerical simulations over the Florida offshore waters using 2-km SST composites derived from the MODIS instrument aboard the polar-orbiting Aqua and Terra Earth Observing System satellites. To help quantify the value of this impact on NWS Weather Forecast Offices (WFOs), the SPoRT Center and the NWS WFO at Miami, FL (MIA) are collaborating on a project to investigate the impact of using the high-resolution MODIS SST fields within the Weather Research and Forecasting (WRF) prediction system. The scientific hypothesis being tested is: More accurate specification of the lower-boundary forcing within WRF will result in improved land/sea fluxes and hence, more accurate evolution of coastal mesoscale circulations and the associated sensible weather elements. The NWS MIA is currently running the WRF system in real-time to support daily forecast operations, using the National Centers for Environmental Prediction Nonhydrostatic Mesoscale Model dynamical core within the NWS Science and Training Resource Center's Environmental Modeling System (EMS) software; The EMS is a standalone modeling system capable of downloading the necessary daily datasets, and initializing, running and displaying WRF forecasts in the NWS Advanced Weather Interactive Processing System (AWIPS) with little intervention required by forecasters. Twenty-seven hour forecasts are run daily with start times of 0300,0900, 1500, and 2100 UTC on a domain with 4-km grid spacing covering the southern half of Florida and the far western portions of the Bahamas, the Florida Keys, the Straights of Florida, and adjacent waters of the Gulf of Mexico and Atlantic Ocean. Each model run is initialized using the Local Analysis and Prediction System (LAPS) analyses available in AWIPS, invoking the diabatic. "hot-start" capability. In this WRF model "hot-start", the LAPS-analyzed cloud and precipitation features are converted into model microphysics fields with enhanced vertical velocity profiles, effectively reducing the model spin-up time required to predict precipitation systems. The SSTs are initialized with the NCEP Real-Time Global (RTG) analyses at l/12 degree resolution (approx. 9 km); however, the RTG product does not exhibit fine-scale details consistent with its grid resolution. SPoRT is conducting parallel WRF EMS runs identical to the operational runs at NWS MIA in every respect except for the use of MODIS SST composites in place of the RTG product as the initial and boundary conditions over water. The MODIS SST composites for initializing the SPoRT WRF runs are generated on a 2-km grid four times daily at 0400, 0700, 1600, and 1900 UTC, based on the times of the overhead passes of the Aqua and Terra satellites. The incorporation of the MODIS SST composites into the SPoRTWRF runs is staggered such that the 0400UTC composite initializes the 0900 UTC WRF, the 0700 UTC composite initializes the 1500 UTC WRF, the 1600 UTC composite initializes the 2100 UTC WRF, and the 1900 UTC composite initializes the 0300 UTC WRF. A comparison of the SPoRT and Miami forecasts is underway in 2007, and includes quantitative verification of near-surface temperature, dewpoint, and wind forecasts at surface observation locations. In addition, particular days of interest are being analyzed to determine the impact of the MODIS SST data on the development and evolution of predicted sea/land-breeze circulations, clouds, and precipitation. This paper will present verification results comparing the NWS MIA forecasts the SPoRT experimental WRF forecasts, and highlight any substantial differences noted in the predicted mesoscale phenomena.

Case, Jonathan L.↗

The Second LBA Calibrator Survey of Southern Compact Extragalactic Radio Sources – LCS2

We present the second catalogue of accurate positions and correlated flux densities for 1100 compact extragalactic radio sources that were not observed before 2008 at high angular resolution. The catalogue spans the declination range [-90◦, -30◦] and was constructed from 19 24-h VLBI observing sessions with the Australian Long Baseline Array at 8.3 GHz. The catalogue presents the final part of the program that was started in 2008. The goals of that campaign were (1) to extend the number of compact radio sources with precise coordinates and measure their correlated flux densities, which can be used for phase referencing very long baseline interferometry (VLBI) and Atacama Large Millimeter/submillimeter Array (ALMA) observations, geodetic VLBI, search for sources with significant offsets with respect to Gaia positions, and space navigation; (2) to extend the complete flux-limited sample of compact extragalactic sources to the Southern hemisphere; and (3) to investigate the parsec-scale properties of sources from the high-frequency AT20G survey. The median uncertainty of the source positions is 3.5 mas. As a result of this VLBI campaign, the number of compact radio sources south of declination -40◦ that have measured VLBI-correlated flux densities and positions known to milliarcsecond accuracy has increased by over a factor of 6.

Petrov, Leonid↗

Compact ultrahigh vacuum sample environments for x-ray nanobeam diffraction and imaging

X-ray nanobeams present the opportunity to obtain structural insight in materials with small volumes or nanoscale heterogeneity. The effective spatial resolution of the information derived from nanobeam techniques depends on the stability and precision with which the relative position of the x-ray optics and sample can be controlled. Nanobeam techniques include diffraction, imaging, and coherent scattering, with applications throughout materials science and condensed matter physics. Sample positioning is a significant mechanical challenge for x-ray instrumentation providing vacuum or controlled gas environments at elevated temperatures. Such environments often have masses that are too large for nanopositioners capable of the required positional accuracy of the order of a small fraction of the x-ray spot size. Similarly, the need to place x-ray optics as close as 1 cm to the sample places a constraint on the overall size of the sample environment. We illustrate a solution to the mechanical challenge in which compact ion-pumped ultrahigh vacuum chambers with masses of 1–2 kg are integrated with nanopositioners. The overall size of the environment is sufficiently small to allow their use with zone-plate focusing optics. We describe the design of sample environments for elevated-temperature nanobeam diffraction experiments demonstrate in situ diffraction, reflectivity, and scanning nanobeam imaging of the ripening of Au crystallites on Si substrates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High resolution hard x-ray microscope on a second generation synchrotron source

A full-field, transmission x-ray microscope (TXM) operating in the energy range of 7-11 keV has been installed at the U7A beamline at the National Synchrotron Radiation Laboratory, a second generation synchrotron source operating at 0.8 GeV. Although the photon flux at sample position in the operating energy range is significantly low due to its relatively large emittance, the TXM can get high quality x-ray images with a spatial resolution down to 50 nm with acceptable exposure time. This TXM operates in either absorption or Zernike phase contrast mode with similar resolution. This TXM is a powerful analytical tool for a wide range of scientific areas, especially studies on nanoscale phenomena and structural imaging in biology, materials science, and environmental science. We present here the property of the x-ray source, beamline design, and the operation and key optical components of the x-ray TXM. Plans to improve the throughput of the TXM will be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Multi Optical Transition Radiation System

The determination and monitoring of the transverse phase space in ATF2 is crucial in order to meet their performances specifications. Since the beam sizes at the Interaction Point (IP) depend strongly on the aberrations in the Final Focus System (FFS), accurate measurement upstream of the FFS is required to tune the beam sizes at the IP. The beam sizes as well as the emittance are measured in several locations in the beam diagnostic section of the Extraction Line (EXT line) of ATF2. The vertical beam sizes in the diagnostic section are of the order of 10 {mu}m this means that the devices have to image spot sizes as small as 5 {mu}m, with 10% accuracy a 2 {mu}m resolution device is necessary. The ATF2 EXT line is a beam line with low power and low repetition rate that make usable devices using solid targets. In contrast to a ring machine, where an individual bunch can be measured many times as it passes around the ring, the beam size and the emittance measurement in the LC or in the beam lines have to be performed in a single pass. This requires that the wire scan device types (laser or solid) sample across successive bunches within a train, often with an over-estimation of the beam size due to beam position and intensity jitter, and can take up to half a minute to complete the measurement. Although some of these effects could be corrected, as the jitter effect could be subtracted by using the nearby BPMs signals, this can be avoided by using Optical Transition Radiation (OTR) Monitors. These monitors are based on the transition radiation effect, a light cone emitted when the charged particle crosses a metallic interface. This light is emitted in a specular fashion so it can be focused on to a CCD and produces an image of the beam. OTRs are able to take many fast measurements and therefore to measure the emittance with high statistics, giving a low error and a good understanding of the emittance jitter. In this article, simulations of the expected beam sizes and emittance, along with a technical description of the system, its hardware and software implementation are described. Additionally first measurement of the beam size and emittance of the Multi Optical Transition Radiation System located in the Extraction Line of ATF2 are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The bones of the Milky Way

The very long and thin infrared dark cloud 'Nessie' is even longer than had been previously claimed, and an analysis of its Galactic location suggests that it lies directly in the Milky Way's mid-plane, tracing out a highly elongated bone-like feature within the prominent Scutum-Centaurus spiral arm. Re-analysis of mid-infrared imagery from the Spitzer Space Telescope shows that this infrared dark cloud (IRDC) is at least two and possibly as many as five times longer than had originally been claimed by Nessie's discoverers; its aspect ratio is therefore at least 300:1 and possibly as large as 800:1. A careful accounting for both the Sun's offset from the Galactic plane (∼25 pc) and the Galactic center's offset from the (l{sup II} , b{sup II} ) = (0, 0) position shows that the latitude of the true Galactic mid-plane at the 3.1 kpc distance to the Scutum-Centaurus Arm is not b = 0, but instead closer to b = –0.4, which is the latitude of Nessie to within a few parsecs. An analysis of the radial velocities of low-density (CO) and high-density (NH{sub 3}) gas associated with the Nessie dust feature suggests that Nessie runs along the Scutum-Centaurus Arm in position-position-velocity space, which means it likely forms a dense 'spine' of the arm in real space as well. The Scutum-Centaurus Arm is the closest major spiral arm to the Sun toward the inner Galaxy, and, at the longitude of Nessie, it is almost perpendicular to our line of sight, making Nessie the easiest feature to see as a shadow elongated along the Galactic plane from our location. Future high-resolution dust mapping and molecular line observations of the harder-to-find Galactic 'bones' should allow us to exploit the Sun's position above the plane to gain a (very foreshortened) view 'from above' the Milky Way's structure.

79 ASTRONOMY AND ASTROPHYSICS↗

A versatile Johansson-type tender x-ray emission spectrometer

We present a high energy resolution x-ray spectrometer for the tender x-ray regime (1.6–5.0 keV) that was designed and operated at Stanford Synchrotron Radiation Lightsource. The instrument is developed on a Rowland geometry (500 mm of radius) using cylindrically bent Johansson analyzers and a position sensitive detector. By placing the sample inside the Rowland circle, the spectrometer operates in an energy-dispersive mode with a subnatural line-width energy resolution (~0.32 eV at 2400 eV), even when an extended incident x-ray beam is used across a wide range of diffraction angles (~30° to 65°). The spectrometer is enclosed in a vacuum chamber, and a sample chamber with independent ambient conditions is introduced to enable a versatile and fast-access sample environment (e.g., solid/gas/liquid samples, in situ cells, and radioactive materials). The design, capabilities, and performance are presented and discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Defining the genetic components of callus formation: A GWAS approach

A characteristic feature of plant cells is the ability to form callus from parenchyma cells in response to biotic and abiotic stimuli. Tissue culture propagation of recalcitrant plant species and genetic engineering for desired phenotypes typically depends on efficient in vitro callus generation. Callus formation is under genetic regulation, and consequently, a molecular understanding of this process underlies successful generation for propagation materials and/or introduction of genetic elements in experimental or industrial applications. Herein, we identified 11 genetic loci significantly associated with callus formation in Populus trichocarpa using a genome-wide association study (GWAS) approach. Eight of the 11 significant gene associations were consistent across biological replications, exceeding a chromosome-wide–log10 (p) = 4.46 [p = 3.47E-05] Bonferroni-adjusted significance threshold. These eight genes were used as hub genes in a high-resolution co-expression network analysis to gain insight into the genome-wide basis of callus formation. A network of positively and negatively co-expressed genes, including several transcription factors, was identified. As proof-of-principle, a transient protoplast assay confirmed the negative regulation of a Chloroplast Nucleoid DNA-binding-related gene (Potri.018G014800) by the LEC2 transcription factor. Many of the candidate genes and co-expressed genes were 1) linked to cell division and cell cycling in plants and 2) showed homology to tumor and cancer-related genes in humans. The GWAS approach based on a high-resolution marker set, and the ability to manipulate targets genes in vitro, provided a catalog of high-confidence genes linked to callus formation that can serve as an important resource for successful manipulation of model and non-model plant species, and likewise, suggests a robust method of discovering common homologous functions across organisms.

59 BASIC BIOLOGICAL SCIENCES↗