Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Coordinated Control of Wind Turbine and Energy Storage System for Reducing Wind Power Fluctuation

This paper proposes a method for the coordinated control of a wind turbine and an energy storage system (ESS). Because wind power (WP) is highly dependent on wind speed, which is variable, severe stability problems can be caused in power systems, especially when the WP has a high penetration level. To solve this problem, many power generation corporations or grid operators have begun using ESSs. An ESS has very quick response and good performance for reducing the impact of WP fluctuation; however, its installation cost is high. Therefore, it is important to design the control algorithm by considering both the ESS capacity and WP fluctuation. Thus, we propose a control algorithm to mitigate the WP fluctuation by using the coordinated control between the wind turbine and the ESS by considering the ESS capacity and the WP fluctuation. Using de-loaded control, according to the WP fluctuation and ESS capacity, we can expand the ESS lifespan and improve grid reliability by avoiding the extreme value of state of charge (SoC) (i.e., 0 or 1 pu). The effectiveness of the proposed method was validated via MATLAB/Simulink by considering a small power system that includes both a wind turbine generator and conventional generators that react to system frequency deviation. We found that the proposed method has better performance in SoC management, thereby improving the frequency regulation by mitigating the impact of the WP fluctuation on the small power system.

17 WIND ENERGY↗

CyDER: A Cyber Physical Co-simulation Platform for Distributed Energy Resources in Smartgrids

The CyDER project aimed at developing an open-source, modular and scalable co-simulation platform for power grids with large shares of Distributed Energy Resources (DERs). The project partners are the Lawrence Berkeley National Lab (LBNL), Lawrence Livermore National Lab (LLNL), PG&E, SolarCity, and ChargePoint. The prime recipient is LBNL; SolarCity and ChargePoint were partners for the project’s first two years. Increased DER integration introduces a number of challenges in power grid operation including a more dynamic interaction between the transmission grid and distribution grids, and increased modeling complexity. Although specialized software exists to precisely model different components of the power system, it is far from trivial to integrate all various models and perform a holistic simulation. Instead of replicating all models in a common simulation program, a commonly accepted approach to tackle this model diversity is to couple third-party simulators and models through a co-simulation platform that coordinates information exchange among the various components. Following this line of research, this project’s objective was to develop a co-simulation platform based on a widely accepted industrial standard called Functional Mockup Interface (FMI). Within this process, the project developed models compliant with the FMI standard, called Functional Mockup Units (FMUs), and used them to perform various operational and planning power system analyses. Relying and building upon an industrial standard is the main differentiation of this project compared with previous or parallel efforts in the co-simulation area. Particular emphasis was put on delivering software utilities to facilitate setting up and running co-simulations by end-users. Furthermore, a strong aspect of this project is demonstrating that co-simulation techniques can be used to perform Hardware-in-the-Loop (HIL) simulations that couple software components (e.g., simulated models) with hardware components (e.g., real devices such PV systems and batteries). The long-term goal of CyDER project is to help establish FMI as a powerful standard for co-simulation and promote adoption by electric utilities and other interested stakeholders. The main accomplishments of the project include the development of several FMUs including distribution and transmission grid models, PV inverters with Volt/Var/Watt controllers, batteries, and predictive optimal controllers. Additionally, a unique software package was developed, called SimulatorToFMU, which is capable of exporting any Python-driven simulator or Python script as an FMU. This is an important contribution towards establishing FMI as one of the main co-simulation standards, because more and more third-party programs for sub-system modeling and simulation are delivered with Python APIs. The CyDER platform was used to perform PV hosting capacity analyses in real utility feeders with and without smart inverter controls, battery storage, and EV charging. Smart inverter controls include conventional Volt/Var/Watt controls for reactive power support and active power curtailment, but also predictive controls that optimize the charging and discharging profile of the battery connected on the DC side in order to minimize the customer’s economic benefit. Finally, an important result of this project is delivering an experimental setup that consists of residential-scale PV inverters with battery storage, a real-time grid simulator with an ideal voltage source as grid emulator, and micro Phasor Measurement Units (PMUs). All these components and additional software modules are coupled to one another using the FMI standard and can be co-simulated with the CyDER platform.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hardware-in-the-Loop Test Bed and Test Methodology for Microgrid Controller Evaluation

Increasing penetration levels of distributed energy resources are making the deployment of microgrids more feasible. Controllers that operate such microgrids are key to realizing the objectives of the microgrid owner or operator and there is a need to evaluate microgrid controller performance prior to field deployment. This paper describes a controller hardware-in-the-loop and power hardware-in-the-loop microgrid controller test bed that was designed and constructed to evaluate the capabilities of a microgrid controller for a proposed campus microgrid. This paper also presents a test methodology to evaluate microgrid controller functionality, and it describes how the controller was assessed through the application of different test scenarios. Results from the testing are presented to provide insight into the capabilities of the test bed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Iterative Linearization for Phasor-Defined Optimal Power Dispatch

Optimal power flow (OPF) problems, which dispatch power targets to controllable generating units across a network, must generally account for non-convex constraints on power flow. Furthermore, adapting those problems so as to make them solvable with convex optimization techniques is an area of much academic and operational interest. In this paper, we present a method for solving OPF as a quadratic program by iteratively refining and re-initializing a linearized model of power flow based on the outputs of an associated nonlinear solver. The linear model on which we demonstrate this method is an adapted version of an approximation designed for use with unbalanced distribution networks. As an important benefit, the model allows for the explicit inclusion of nodal voltage phasor values in both the OPF problem's objective and its constraints, which opens the door to the idea of phasor-based control (PBC) design. We show in simulations on the IEEE 13-node test feeder that our method quickly converges to a set of phasor targets that are sufficiently precise for use in operations at the distribution level.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design and Analysis of an Integral MPPT Control Law for Wave Energy Conversion Systems

In this paper, we propose an integral-based maximum power point tracking (MPPT) algorithm for point absorber wave energy conversion (WEC) systems. A permanent magnet synchronous generator (PMSG) is coupled to the point absorber and its drive implements the proposed MPPT control. While the rotating frame of reference of the PMSG implements power control, the slower mechanical frequency of the incident waves are processed with an additional transformation that yields another set of dc dynamics. The computed dc power in the new reference frame, which is focused on slow wave dynamics, is input to the MPPT control law that tunes the emulated resistance of the machine drive to extract peak power from the wave absorber device. We derive a stability condition for the proposed controller and validate our control design on a simulated 10kW system.

wave energy, maximum power point tracking (MPPT), ↗

Substrate thermal conductivity controls the ability to manufacture microstructures via laser-induced direct write

In controlling the thermal properties of the surrounding environment, we provide insight into the underlying mechanisms driving the widely used laser direct write method for additive manufacturing. In this study, we find that the onset of silver nitrate reduction for the formation of direct write structures directly corresponds to the calculated steady-state temperature rises associated with both continuous wave and high-repetition rate, ultrafast pulsed laser systems. Furthermore, varying the geometry of the heat affected zone, which is controllable based on in-plane thermal diffusion in the substrate, and laser power, allows for control of the written geometries without any prior substrate preparation. In conclusion, these findings allow for the advance of rapid manufacturing of micro- and nanoscale structures with minimal material constraints through consideration of the laser-controllable thermal transport in ionic liquid/substrate media.

36 MATERIALS SCIENCE↗

Achievement in Beam Power Records for the NOvA Target System

We began upgrading the NOvA target system for 1-Mega Watt (1-MW) beam operation in 2017. Major challenges included maintaining the quality of neutrino beams with reliable instrumentation, reducing instantaneous beam heating on the target, increasing cooling power to handle the high-power beam, and controlling tritium water production rate. We finally achieved a one-hour beam power record of 1.018 MW in Summer 2024. This milestone demonstrates our capability to operate at 2+ MW beam power for the future Long Baseline Neutrino Facility (LBNF) and Deep Underground Neutrino Experiment (DUNE).

43 PARTICLE ACCELERATORS↗

Tool employing homotopy-based approaches in finding the controlling unstable equilibrium point in the electric power grid

The analysis tool employs a computer-implemented algorithm that uses homotopy-based approaches to map the solution from the exit point to the controlling unstable equilibrium point (UEP). The computational time is reduced significantly by using an approximate exit point rather than computing an accurate exit point as it is required in finding the controlling UEPs using traditional transient stability direct methods. In addition, this method eliminates the necessity of computing the minimum gradient point (MGP) which is a key element in using Newton methods. These properties provide an advantage to homotopy-based approaches over traditional iterative methods in terms of both speed of computation and reliability of finding solutions.

97 MATHEMATICS AND COMPUTING↗

Towards a Cyber Defense Framework for SCADA Systems Based on Power Consumption Monitoring

Supervisory control and data acquisition (SCADA) is an industrial automation system that remotely monitor, and control critical infrastructures. SCADA systems are major targets for espionage and sabotage attackers. According to the 2015 Dell security annual threat report, the number of cyber-attacks against SCADA systems has doubled in the past year. Cyber-attacks (i.e., buffer overflow, rootkits and code injection) could cause serious financial losses and physical infrastructure damages. Moreover, some specific cyber-attacks against SCADA systems could become a threat to human life. Current commercial off-the-shelf security solutions are insufficient in protecting SCADA systems against sophisticated cyber-attacks. In 2014 a report by Mandiant stated that only 69% of organizations learned about their breaches from third entities, meaning that these companies lack of their own detection system. Furthermore, these breaches are not detected in real-time or fast enough to prevent further damages. The average time between compromise and detection (for those intrusions that were detected) was 205 days. To address this challenge, we propose an Intrusion Detection System (IDS) that detects SCADA-specific cyber-attacks by analyzing the power consumption of a SCADA device. Specifically, to validate the proposed approach, we chose to monitor in real-time the power usage of a a Programmable Logic Controller (PLC). To this end, we configured the hardware of the tetsbed by installing the required sensors to monitor and collect its power consumption. After that two SCADA-specific cyber-attacks were simulated and TracerDAQ Pro was used to collect the power consumption of the PLC under normal and anomalous scenarios. Results showed that is possible to distinguish between the regular power usage of the PLC and when the PLC was under specific cyber-attacks.

Hernandez Jimenez, Jarilyn M↗

Meta-Level Design Guidance and Operator Performance Measures for Hybrid Control Rooms

The purpose of this grant was to refine and test methods to evaluate digital human system interfaces (HSI) for existing largely analog nuclear power plant (NPP) control rooms (CRs). We hypothesized that CR operator performance (CROP) in hybrid NPP CRs will be improved if future digital HSI is designed based on: 1) more robust design guidelines for operator situation awareness (SA) and decision-making (DM); 2) enhanced CROP metrics during HSI evaluation; 3) an ontology for selecting simulation scenarios to evaluate digital HSI; and 4) a model to predict optimal HSI design attributes given CROP objectives. The team conducted numerous nuclear power plant site visits (e.g., to Brown’s Ferry, Palo Verde, Sequoyah and Vogtle) to study control room operations and crisis management and 3 visits to the NRC Chattanooga Training Center. We observed research studies at DC Cook and NRC Chattanooga in collaboration with the Halden Reactor Project. We collected operator performance and workload data in one NPP simulator. A comprehensive human (i.e., CROP) performance literature review was published in Applied Ergonomics. We obtained operator team performance data from CAER to produce our data fusion model and a paper delineating the results have been accepted (revision submitted) in Resilience Engineering and System Safety. We analyzed interview data related to scenario ontology development; a manuscript is still in preparation.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Reliability Assessment of Safety-Critical Network Communication in a Digitalized Nuclear Power Plant

In analog instrumentation and control (I and C) systems for nuclear power plants (NPPs), most connections are comprised of hardwired point-to-point types. Since they are based on analog technologies, they are fragile to noise and require analog-to-digital conversion time. Therefore, many NPPs have adopted communication network for the exchange of safety-critical data between programmable logic controllers (PLCs) in digital I and C systems to effectively accommodate a huge number of field controllers. However, the primary issue of digital network communication in a safety-critical system involves potential hazards, such as partial or total loss of communication between PLCs, which may result in a failure of safety critical signal generation when it is needed. Therefore, the probability that a safety-critical system in digitalized NPP becomes unsafe due to a network failure must be evaluated to quantify the risk of digital I and C system. In Korea, the Engineered Safety Feature-Component Control System (ESF-CCS) was developed as one of the digital safety-critical system in Advanced Power Reactor- 1400 (APR-1400). The function of a digital engineered safety feature (ESF) actuation system and field actuator controllers of conventional NPPs are performed by the ESF-CCS. In this system, safety-critical network, High Reliable- Safety Data Network (HR-SDN), was employed for the safety-critical data transmission from group controllers (GCs) to loop controllers (LCs). In this study, a framework for assessing the reliability of a HR-SDN network communication between GCs and LCs in the ESF-CCS in addition to a fault-tree model for ESF components considering network failure between GCs and LCs were developed to assess the plant risk effect of a newly developed digitalized ESF-CCS. Based on the case studies and cut set analysis, the risk effect of network failure on plant risk and the important risk contributors of network failure were quantitatively addressed. A framework for identifying the potential hazardous states of network communication in the ESFCCS was proposed. In addition, a fault-tree model for network communication failure was developed to estimate the risk effects of network failure between the GCs and LCs on ESF-CCS signal failure. The developed fault-tree model was then applied to several case studies. The fault-tree model of ESF-CCS signal failure for ESF components required for various mitigation actions regarding NPP DBAs was designed by considering the identified hazardous states of network failure that would result in a failure to provide input signals to the corresponding LC. As a sensitivity study, three case studies were performed based on the periodic test methods for hardware components in HR-SDN module and their test intervals in this study. The quantitative results for three case studies demonstrated that the probability of overall network communication failure, which was calculated as the sum of the failure probability associated with each failure cause, contributed up to 1.58% on the Small-LOCA CD frequency. The results also revealed the important basic events related to network failure in the case studies which included CCF of hardware and software in HR-SDN module. This study is expected to provide insight into the development of the fault-tree model for the network failure in digital I and C system and into the quantification of the risk effect of network failure for safety-critical data transmission in NPPs. As a further study, the risk effects of network failure in the ESF-CCS on the plant risk can be estimated in a more detailed manner by analyzing the failure modes and causes in a sub-component level and the fault detection coverage of the fault tolerance techniques for network failure implemented in ESF-CCS after the detailed configuration of ESF-CCS is decided. In terms of the failure of manual ESF actuation, the relationship among the human action failures must be investigated to consider multiple human error condition since ESF-CCS provides multiple manual actuation to assure the diversity of the system. Since the conventional HEP method cannot accommodate the multiple conditions in a fault tree, condition-based human reliability assessment (CBHRA) method or the dynamic human reliability modeling approach can be applied to include a complex relationship among the automated safety signal generation and the human operator's manual actuation, avoiding the optimistic estimation of HEP of the human action failure.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Chapter 7: Learning Stable Local Volt/Var Controllers in Distribution Grids

This chapter describes a framework to synthesize provably stable local Volt/Var controllers for distributed energy resources (DERs) in power distribution grids (DGs). The goal is to control the reactive power injections of DERs to improve the system performance as quantified by a generic optimal reactive power flow (ORPF) problem. To achieve this, we jointly design for each DER the control function, which prescribes the reactive power update rule, and the equilibrium function, which approximates the ORPF solutions from local measurements of voltages and powers. We provide conditions on the equilibrium functions and the control parameters ensuring the stability of the closed-loop system. In particular, we discuss the trade-offs between each set of conditions accounting for practical considerations, like fully exploiting the DERs' generation capabilities and reducing the optimality gap. These conditions are then translated into learning constraints on the neural networks' parameters that are enforced in the training phase. We validate our framework with numerical simulations on the IEEE 37-bus network and through a comparison with an optimized version of standard piece wise linear control rules.

closed-loop asymptotic stability↗

GridOPTICS(TM) A Novel Software Framework for Integrating Power Grid Data Storage, Management and Analysis

This paper describes the architecture and design of GridOPTICSTM, a novel software framework to integrate a collection of software tools developed by PNNL’s Future Power Grid Initiative (FPGI) into a coherent, powerful operations and planning tool for the power grid of the future. GridOPTICSTM enables plug-and-play of various analysis, modeling and visualization software tools for fast and accurate control of the power grid. To bridge the data access for different control purposes, GridOPTICSTM provides a scalable and thin layer of event processing that hides the complexity of data storage and management. The initial prototype of GridOPTICSTM was demonstrated with several use cases from PNNL’s FPGI.

GridOPTICS, power grid, software framework↗

GRIDAPPSD/distopf (33583-E)

DistOPF is an open-source Python package providing a three-phase, asymmetric optimal power flow (OPF) tool specifically designed for distribution systems. The key inventive features include: - Asymmetrical 3-phase OPF modeling for distribution systems with unbalanced phases - Comprehensive control optimization supporting both active (P) and reactive (Q) power control variables - Built-in visualization and validation tools - Standard test system benchmarking platform for algorithm development and comparison - Modular CSV-based input system using Pandas DataFrames for flexible model specification - Standard power distribution model importer enabling direct conversion from CIM and OpenDSS format to optimization-ready models - Multiple solve interface compatibility (PYOMO, CVXPY, SciPy) with automatic solver selection based on problem type

Gray, Nathan [Pacific Northwest National Laborator↗

A Tariff for Reactive Power

Two kinds of power are required to operate an electric power system: real power, measured in watts, and reactive power, measured in volt-amperes reactive or VARs. Reactive power supply is one of a class of power system reliability services collectively known as ancillary services, and is essential for the reliable operation of the bulk power system. Reactive power flows when current leads or lags behind voltage. Typically, the current in a distribution system lags behind voltage because of inductive loads such as motors. Reactive power flow wastes energy and capacity and causes voltage droop. To correct lagging power flow, leading reactive power (current leading voltage) is supplied to bring the current into phase with voltage. When the current is in phase with voltage, there is a reduction in system losses, an increase in system capacity, and a rise in voltage. Reactive power can be supplied from either static or dynamic VAR sources. Static sources are typically transmission and distribution equipment, such as capacitors at substations, and their cost has historically been included in the revenue requirement of the transmission operator (TO), and recovered through cost-of-service rates. By contrast, dynamic sources are typically generators capable of producing variable levels of reactive power by automatically controlling the generator to regulate voltage. Transmission system devices such as synchronous condensers can also provide dynamic reactive power. A class of solid state devices (called flexible AC transmission system devices or FACTs) can provide dynamic reactive power. One specific device has the unfortunate name of static VAR compensator (SVC), where 'static' refers to the solid state nature of the device (it does not include rotating equipment) and not to the production of static reactive power. Dynamic sources at the distribution level, while more costly would be very useful in helping to regulate local voltage. Local voltage regulation would reduce system losses, increase circuit capacity, increase reliability, and improve efficiency. Reactive power is theoretically available from any inverter-based equipment such as photovoltaic (PV) systems, fuel cells, microturbines, and adjustable-speed drives. However, the installation is usually only economical if reactive power supply is considered during the design and construction phase. In this report, we find that if the inverters of PV systems or the generators of combined heat and power (CHP) systems were designed with capability to supply dynamic reactive power, they could do this quite economically. In fact, on an annualized basis, these inverters and generators may be able to supply dynamic reactive power for about $5 or $6 per kVAR. The savings from the local supply of dynamic reactive power would be in reduced losses, increased capacity, and decreased transmission congestion. The net savings are estimated to be about $7 per kVAR on an annualized basis for a hypothetical circuit. Thus the distribution company could economically purchase a dynamic reactive power service from customers for perhaps $6/kVAR. This practice would provide for better voltage regulation in the distribution system and would provide an alternate revenue source to help amortize the cost of PV and CHP installations. As distribution and transmission systems are operated under rising levels of stress, the value of local dynamic reactive supply is expected to grow. Also, large power inverters, in the range of 500 kW to 1 MW, are expected to decrease in cost as they become mass produced. This report provides one data point which shows that the local supply of dynamic reactive power is marginally profitable at present for a hypothetical circuit. We expect that the trends of growing power flow on the existing system and mass production of inverters for distributed energy devices will make the dynamic supply of reactive power from customers an integral component of economical and reliable system operation in the future.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Automated setup for magnetic hysteresis characterization based on a voltage controlled current source with 500 kHz full power bandwidth and 10 A peak-to-peak current

This paper describes the design of a system for the characterization of magnetic hysteresis behavior in soft ferrite magnetic cores. The proposed setup can test magnetic materials exciting them with controlled arbitrary magnetic field waveforms, including the capability of providing a DC bias, in a frequency bandwidth up to 500 kHz, with voltages up to 32 V peak-to-peak, and currents up to 10 A peak-to-peak. In order to have an accurate control of the magnetic field waveform, the system is based on a voltage controlled current source. The electronic design is described focusing on closed loop feedback stabilization and passive components choice. The system has real-time hysteretic loop acquisition and visualization. The comparisons between measured hysteresis loops of sample magnetic materials and datasheet available ones are shown. Results showing frequency and thermal behavior of the hysteresis of a test sample prove the system capabilities. Moreover, the B-H loops obtained with a multiple waveforms excitation signal, including DC bias, are reported. The proposal is a low-cost and replicable solution for hysteresis characterization of magnetic materials used in power electronics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗