Search NASA⌕ Search

SEARCH · Search NASA

Results for “RESIDENTIAL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Green buffers near industrial plants, examples in Jefferson County TX

Green buffers between industrial plants and residential areas have multiple purposes in mitigating air pollution and protecting the environment. This study focuses on providing information on examples of green space development by industries near residential areas in Jefferson County, Texas. One represents a full buffer where residences were totally removed, another is a partial buffer where some residences were removed in a neighborhood and the third represents vegetation of a formerly industrial facility. Additional estimates on benefits of buffer spaces with respect to a pollutant plume are also considered. The study used geospatial and property data from 1966 to 2020. The transition from a residential area to a full or partial buffers highlights possible mitigation of air pollution impacts while serving additional functions, such as boosting stormwater infiltration and improving the aesthetic attractiveness of the area. The transformation from oil tanks to forested space may display the potential for environmental remediation, but not all spaces are suitable for fully forested buffers, as safety and other limitations should be considered. With the analysis of the classic Plume Equation insights can be provided regarding the possible impact of green buffers on ground-level pollutant concentrations. The calculations for atmospheric stability classes A-F and for various stack heights provide an understanding of how different conditions may affect the pollutant concentrations. The presence of a green buffer can play a crucial role in controlling ground-level pollution concentrations and reduce a community’s perception of risk.

54 ENVIRONMENTAL SCIENCES↗

Assessing the hygrothermal performance of bio-based materials in building wall systems

Building envelope systems are crucial in regulating thermal and moisture exchange between interior and exterior environments, accounting for approximately 28 % of building energy consumption in the United States with walls being the primary contributors. Improper selection of building envelope materials can lead to moisture-related issues, reduced resilience, and compromised durability. Hygrothermal performance assessment is a key factor in efficient building design. As such, improving the energy and hygrothermal performance of opaque wall materials, through careful assessment of material choices, is essential to enhancing building resilience, lowering energy costs, and improving occupant comfort. As the building industry seeks new strategies to reduce material energy intensity, bio-based materials emerge as a promising solution. However, their long-term hygrothermal performance in building envelope systems remains underexplored. To fill this gap, this study evaluates the hygrothermal behavior of 13 bio-based materials in residential wall systems across three U.S. climate zones. Laboratory experiments were performed to measure material properties such as density, thermal conductivity, moisture transmission, and sorption isotherms. These data were integrated into the WUFI® simulation tool to assess wall hygrothermal performance in Houston, Baltimore, and Chicago. A three-phase modeling approach was used: (1) baseline residential walls with oriented strand board (OSB) and gypsum board; (2) replacing OSB with bio-based materials; and (3) replacing drywall with bio-based materials. Results showed that the evaluated bio-based materials maintained acceptable moisture thresholds of ≤ 16 % across all climates, confirming their viability as an alternative for current sheathing materials. Furthermore, this study provides a foundation for future research and innovation in material science on the use of certain bio-based materials in high-performance, low energy use residential construction. Ultimately, providing critical data, offering a database of bio-based material properties, and supplying a simulation-based approach will help designers make informed decisions for future efficient building practices.

Bio-based materials↗

Evaluation of Phase Change Plaster/Paste Composites for Building Envelopes

Thermal energy storage (TES) materials increase a building’s thermal mass and provide the flexibility to shave and time-shift energy use. These materials are needed to enable grid-interactive efficient buildings, allowing building occupants to lower costs by leveraging free ambient heating/cooling as well as shifting consumption to cheaper electricity periods. Phase change materials (PCMs) that store heat through a solid-liquid/solid-solid transformation are of particular interest for TES because of their ability to store large amounts of energy across a constant temperature or very small temperature range. Furthermore, previous studies on PCM building envelopes evaluated products that may only be incorporated as part of new construction and are not easily applicable to existing, energy-intensive buildings. In this work, we leverage laboratory PCM characterization and whole-building energy simulation to study the energy and cost savings of PCM plaster/paste coatings, which can be applied post construction to both new builds and retrofits of existing buildings (about 40% of residential buildings in the United States fall into the retrofit category). We evaluated the energy impact of PCM plaster/paste composites for a single-family residential building in the United States, including layer design (location and thickness), composite properties (phase change temperature, energy density, and shape of the enthalpy curve), and U.S. climate zone. The enthalpy curve shape of PCM shows that phase change temperature and energy density are not the only two parameters that must be considered for PCM selection. Maximizing the energy density amid the effective TES zone is key to boosting energy savings. We also studied PCM price targets with the aim of achieving reasonable payback periods based on both block and time-of-use electricity rates. Moreover, we developed an empirical equation to provide a rough estimate of the energy savings potential of incorporating PCM without the need to perform detailed simulations. These results will help guide the selection and design of PCM plaster/paste composite elements for residential building envelopes.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

An Empirical Validation of a Constrained Bin Packing Algorithm for a Home Energy Management System

The increasing number of intelligent electrical appliances and home energy management systems provide a big opportunity for demand response services from residential and small commercial buildings to the grid. Simultaneously, direct control of individual devices by utilities can cause communication bottlenecks, as well as coordination and privacy concerns. These challenges can be addressed by combining the constituent devices into a single house battery equivalent for the purposes of demand response, using Minkowski sum and a 2d bin packing problem. However, the well-studied traditional problems have not been tested in a real house, as implementation carries significant challenges of its own. We deploy the packing problem on residential devices in a controllable house. We report the barriers we found, such as charge forecast and scalability of the algorithm, and discuss our solutions. The study serves as an intermediate step between existing theoretical research and possible future steps, such as prototype deployments of systems that provide residential demand response.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Updated U.S. Low-Temperature Heating and Cooling Demand by County and Sector

This dataset includes U.S. low-temperature heating and cooling demand at the county level in major end-use sectors: residential, commercial, manufacturing, agricultural, and data centers. Census division-level end-use energy consumption, expenditure, and commissioned power database were dis-aggregated to the county level. The county-level database was incorporated with climate zone, numbers of housing units and farms, farm size, and coefficient of performance (COP) for heating and cooling demand analysis. This dataset also includes a paper containing a full explanation of the methodologies used and maps. Residential data were updated from the latest Residential Energy Consumption Survey (RECS) dataset (2015) using 2020 census data. Commercial data were baselined off the latest Commercial Building Energy Consumption Survey (CBECS) dataset (2012). Manufacturing data were baselined off the latest Manufacturing Energy Consumption Survey (MECS) dataset (2021).

15 GEOTHERMAL ENERGY↗

Evaluation of the Impact of Slab Foundation Heat Transfer on Heating and Cooling in Florida

During the last three decades of energy-efficiency research, there has been limited study of heat transfer to slab-on-grade foundations in cooling-dominated climates. Most experimental research has focused on the impact of slab-on-grade foundations and insulation schemes on heat losses in heating-dominated climates. This is surprising because the floor area in single-family homes is generally equal to wall area, window area, or attic area, all of which have been extensively evaluated for heat-transfer properties. Moreover, slab foundations are the most common foundation type in cooling-dominated climates. Slab-on-grade construction is very popular in southern states, accounting for 77% of new home floors according to 2014 U.S. Census data. There is a widespread perception that tile flooring, as opposed to carpet, provides a cooler home interior in warm climates. Empirical research is needed because building energy simulation software programs running DOE-2 and EnergyPlus engines often rely on simplified models to evaluate the influence of flooring on interior temperature, even though in some cases more detailed models exist. The U.S. Department of Energy Building America Partnership for Improved Residential Construction (BA-PIRC) performed experiments in the Florida Solar Energy Center’s Flexible Residential Test Facility intended to assess for the first time (1) how slab-on-grade construction influences interior cooling in a cooling-dominated climate and (2) how the difference in a carpeted versus uncarpeted building might influence heating and cooling energy use. Two nominally identical side-by-side residential buildings were evaluated during the course of 1 year, from 2014 to 2015: the east building with a pad and carpet floor and the west building with a bare slab floor. A detailed grid shows temperature measurements taken on the slab surface at various locations as well as at depths of 1.0 ft, 2 ft, 5.0 ft, 10.0 ft, and 20.0 ft below the surface. Temperature measurements were taken at both buildings for more than 3 years prior to the experiments to ensure that the ground and foundation temperatures had fully come into equilibrium.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

2015 South Carolina PV Soft Cost and Workforce Development Part 2: Six Month Confirmation of Anticipated Job Growth

In 2015, a program was initiated to carefully track and monitor the growth of the solar industry in SC. Prior to then, little information was available on the costs associated with distributed photovoltaic (PV) installations in the Southeastern US. For this report, data were collected from businesses on the number of hires they had at the end of 2014 and compared with data for 2015 and June 2016. It was found that the percentage of installers within the state who serve the residential sector increased to 82% from 67%. During the same time period, the average size of initiated installations for residential, commercial, and utility scale installations all trended upwards. Where residential installations were typically 5 kW-DC in 2014, they were typically 10 kW-DC by late 2015 and in mid-2016. For commercial installations, the average size grew from 84 kW-DC in 2014 to between 136-236 kW-DC in 2015 and then 188-248 kWDC in mid-2016. An exception was seen in utility scale installations where a 2.3 MW-DC system was common in 2014, the size grew to be 5-15 MW-DC in late 2015. The average size dropped 3.1-4.4 MWDC in mid-June 2016, though individual averages up to 20 MW-DC were reported.

99 GENERAL AND MISCELLANEOUS↗

The Alabama Energy Code Compliance Project

The U.S. Department of Energy (DOE) Building Energy Codes Program launched a series of research studies in 2014 across eight U.S. states (shown in Figure 1) to investigate typical energy efficiency practices in residential buildings and identify opportunities to reduce household utility bills. A primary goal of the study was to help document baseline practices for new single-family construction, target areas for improvement relative to the state energy code, and quantify the related savings potential. This information is intended to assist states in measuring compliance with their energy codes and to identify areas of focus for future education and training initiatives. Following the original baseline studies, project teams in each state conducted a series of education, training, and outreach activities aimed at improving compliance with the state residential energy code. A second baseline study was then implemented in each state with the objective of determining whether the investment in education, training, and outreach programs had produced a significant and measurable change in statewide residential energy use. Through the program, DOE planned to establish a sufficient data set to represent baseline construction trends across states and detect significant changes in energy use resulting from education and training activities. This report outlines the application of the study in the state of Alabama, which was led by the Institute for Market Transformation (IMT). Data gathered have been submitted to Pacific Northwest National Laboratory (PNNL) for analysis. Findings available to date are published as PNNL technical reports on the DOE Building Energy Codes Program website.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Bishop Paiute Single Family Solar Home Project: Phase 4 (Final Technical Report)

The Bishop Paiute Tribe is committed to energy efficiency, renewable energy, and environmental protection and has a vision to install solar energy systems on all buildings on the Reservation where technically feasible. Through completion of the Bishop Paiute Tribe Residential Solar Program – Phase 4, Bishop Paiute Tribe continued its successful model partnering with non-profit solar installer GRID Alternatives to advance its vision and build energy self-sufficiency on the Bishop Paiute Reservation. The Bishop Paiute Tribe Residential Solar Program – Phase IV deployed 67 kW-AC of new clean, renewable energy through grid-tied, net-metered rooftop solar electric systems installed on a total of 20 (one more than the planned 19) existing owner-occupied, single-family homes for low-income families on the Reservation. This represents nearly 14% of the Reservation’s total “unsolarized” homes. These systems were provided at no cost to the homeowners, who will also receive energy efficiency education to further reduce energy consumption and lower electric bills. GRID led a solar installation for three (3) of the homes where Tribal/community members, were given an opportunity in participating in on-the-roof trainings to gain new skills while installing solar for their low-income community members. Subcontractors through GRID Sub Contractor Partnership Program (GRID SPP) led solar installations for seventeen (17) of the homes. Each installation provided paid employment for a solar trainee trainees hired by the SPP subcontractors as entry level solar installers. It is estimated that the installed 67 kW-AC of solar will produce at least 120,000 kWh/year, displacing at least 30-75% of the 20 homes’ total electricity use for a combined system lifetime electricity cost savings for the low-income homeowners of about $\$$500,000. It is further estimated that the installed renewable energy systems installed will prevent greenhouse gases by about 1,000 tons, equivalent to planting approximately 25,000 trees. Following the successful completed installations, it is expected that the Reservation and surrounding communities will benefit from improved air quality via reduced wood stove use for heating. Cumulatively with other initiatives, the project will result in nearly 40% of the Reservation’s solarizable homes being solarized. Overall, the triple impact of the phase 4 of the Bishop Paiute Tribe Residential Solar Program – Phase 4 is: 1) affordable energy for low-income families; 2) on-site clean energy production, 3) hands on training and paid solar installation work for local tribal/community workers. These impacts will support and grow the Tribe’s energy, economic, environmental, and social self-sufficiency and sovereignty amongst the neediest on the Reservation.

14 SOLAR ENERGY↗

Energy Auditor Job Task Analysis

The National Renewable Energy Laboratory (NREL) is contracted by the U.S. Department of Energy (DOE) Weatherization Assistance Program (WAP) to develop and maintain the resources under the Guidelines for Home Energy Professionals (GHEP) project. The purpose of the GHEP project is to increase the quality of work conducted for residential energy retrofits in the United States through the WAP network and other residential retrofit programs. The HEP certifications support WAP and the broader residential home performance industry through the credentialing process and development of defined JTAs for Energy Auditors (EA) and Quality Control Inspectors (QCI). This report outlines the most recent updates (2022) to the EA JTA.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Cold Climate Air-Source Heat Pump Demonstration and Analysis: Experimental Study on Cold Temperature Performance

Space heating energy is the largest end use for U.S. residential buildings, accounting for nearly 45% of residential building energy consumption nationwide, and approximately 51% of space heating energy is consumed on-site by combusting natural gas (EIA 2020a). In Colorado, approximately 53% of the statewide residential building energy consumption goes to space heating, 76% of which is provided by natural gas (EIA 2020a). Heat pumps are an efficient, electric alternative space heating technology and have been proven viable for decades. However, historically air-source heat pumps (ASHPs) have been limited to temperate climates because of (1) subpar performance at extremely cold outdoor air temperatures, (2) the need for air conditioning in summer months, and (3) the availability of natural gas in colder climates. Relatively recent advances to cold climate ASHP technology, which typically relies on inverter-driven, variable-speed compressors and variable-speed fans, have significantly improved low-temperature heat pump performance, enabling the technology to potentially save energy for many homes in cold climates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ResStock Technical Reference Documentation (V.3.3.0)

ResStock™ is the best-in-class building stock energy model for simulating and publishing energy use, utility bills, and greenhouse gas emissions from the residential sector of the U.S. ResStock answers two primary questions: (1) How is energy used in the U.S. residential building stock? and (2) What is the timeseries aggregate impact of energy technologies? Specifically, ResStock quantifies energy use across geographical locations, demographic groups, building types, fuels, end uses, and time of day. Additionally, it details the impact of efficiency or electrification measures: total changes in the amount of energy used by measure; where or in what use cases efficiency or electrification upgrade measures save energy; when or at what times of day savings occur; and which building stock or demographic segments have the biggest savings potential. This model, and the datasets it produces, are foundational to identifying pathways to affordable and equitable decarbonization of the U.S. residential buildings sector.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

BuildingsBench: A Large-Scale Dataset of 900K Buildings and Benchmark for Short-Term Load Forecasting

The BuildingsBench datasets consist of: - Buildings-900K: A large-scale dataset of 900K buildings for pretraining models on the task of short-term load forecasting (STLF). Buildings-900K is statistically representative of the entire U.S. building stock. - 7 real residential and commercial building datasets for benchmarking two downstream tasks evaluating generalization: zero-shot STLF and transfer learning for STLF. Buildings-900K can be used for pretraining models on day-ahead STLF for residential and commercial buildings. The specific gap it fills is the lack of large-scale and diverse time series datasets of sufficient size for studying pretraining and finetuning with scalable machine learning models. Buildings-900K consists of synthetically generated energy consumption time series. It is derived from the NREL End-Use Load Profiles (EULP) dataset (see link to this database in the links further below). However, the EULP was not originally developed for the purpose of STLF. Rather, it was developed to "...help electric utilities, grid operators, manufacturers, government entities, and research organizations make critical decisions about prioritizing research and development, utility resource and distribution system planning, and state and local energy planning and regulation." Similar to the EULP, Buildings-900K is a collection of Parquet files and it follows nearly the same Parquet dataset organization as the EULP. As it only contains a single energy consumption time series per building, it is much smaller (~110 GB). BuildingsBench also provides an evaluation benchmark that is a collection of various open source residential and commercial real building energy consumption datasets. The evaluation datasets, which are provided alongside Buildings-900K below, are collections of CSV files which contain annual energy consumption. The size of the evaluation datasets altogether is less than 1GB, and they are listed out below: 1. ElectricityLoadDiagrams20112014 2. Building Data Genome Project-2 3. Individual household electric power consumption (Sceaux) 4. Borealis 5. SMART 6. IDEAL 7. Low Carbon London A README file providing details about how the data is stored and describing the organization of the datasets can be found within each data lake version under BuildingsBench.

Array↗

Laboratory Resources and Techniques to Evaluate Smart Home Technology: Preprint

Smart home technologies promise to make residential buildings more comfortable, less costly to operate, more energy efficient, and more integrated with the grid, but these systems are difficult to evaluate in traditional laboratory spaces. To aid in the development and evaluation of new home energy management systems (HEMS), NREL built the Systems Performance Laboratory (SPL) within the Energy Systems Integration Facility. SPL has electrical infrastructure for three residential buildings, complete with smart meters, breaker panels and a full complement of major and minor appliances in each 'home.' Cord and plug power connections mean that appliances can easily be swapped for different models. Distributed energy resources (DER), such as residential photovoltaic (PV) inverters and home batteries, are also available for integration. Sensors monitor the power consumption of all loads and controllers can simulate occupancy to drive the appliances in realistic ways. A novel hardware-in-the-loop application was developed to ensure air conditioner cycling by combining a building simulation with a physical air conditioner and a thermostat, which allows us to simulate performance in any climate with any building construction. Another application of the hardware-in-the-loop technique uses a grid simulation to model the grid impact for different control strategies related to smart home technologies. This laboratory is a powerful, flexible tool that can be employed to evaluate the effect that home energy management and other smart home technologies will have at the appliance, whole-home, and distribution feeder levels - all of which are important perspectives for different stakeholders.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of Retrofit Delivery Packages

Residential energy retrofit activities are a critical component of efforts to increase energy efficiency in the U.S. building stock; however, retrofits account for a small percentage of aggregate energy savings at relatively high per unit costs. This report by Building America research team, Alliance for Residential Building Innovation (ARBI), describes barriers to widespread retrofits and evaluates opportunities to improve delivery of home retrofit measures by identifying economies of scale in marketing, energy assessments, and bulk purchasing through pilot programs in portions of Sonoma, Los Angeles, and San Joaquin Counties, CA. These targeted communities show potential and have revealed key strategies for program design, as outlined in the report.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of Retrofit Delivery Packages

Residential energy retrofit activities are a critical component of efforts to increase energy efficiency in the U.S. building stock; however, retrofits account for a small percentage of aggregate energy savings at relatively high per unit costs. This report by Building America research team, Alliance for Residential Building Innovation (ARBI), describes barriers to widespread retrofits and evaluates opportunities to improve delivery of home retrofit measures by identifying economies of scale in marketing, energy assessments, and bulk purchasing through pilot programs in portions of Sonoma, Los Angeles, and San Joaquin Counties, CA. These targeted communities show potential and have revealed key strategies for program design, as outlined in the report.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Exploring urban typologies using comprehensive analysis of transportation dynamics

Abstract As urban areas continue to expand and develop, categorizing cities into typologies offers a valuable framework for understanding metropolitan dynamics and fostering inter-city collaboration. However, existing typologies related to urban mobility have limitations, failing to consider cities within a single large urban region and often overlooking crucial dimensions such as trip demand and traffic flow. In this paper, we introduce a transportation-focused characterization for cities within a large urban region, specifically the San Francisco Bay Area, California. We incorporate over 40 metrics across five transportation dimensions: trip demand, road network, multi-modal network, traffic flow, and land use. Specifically, for the trip demand dimension, we include metrics capturing residents’ trip characteristics, such as mode share, intra-city trips, and inter-city trips. Additionally, we analyze the purpose of trips entering the city to gain a deeper understanding of incoming trip patterns. In the traffic flow dimension, we examine metrics like vehicle miles traveled, delay, and congestion to assess the traffic conditions on the street network. These, combined with other dimensions, provide a comprehensive view of a city’s transportation dynamics. Using unsupervised machine learning clustering methods, we identified eight distinct typologies for the Bay Area: Live Work Cities; Job and Activity Magnet Cities; Anchor Cities; Multi-modal Cities; Hyper-connected Cities; Low-density Residential Cities; Medium-density Residential Cities; and Mixed-use Residential Cities. Our findings show that many clusters are strongly influenced by trip demand and traffic flow metrics. Finally, we examine the practicality of this typology and its potential to guide collaborative transportation management strategies. The typologies provide a foundation for dialogue among Bay Area cities, focusing on evaluating shared characteristics and leveraging successes or challenges to develop unified strategies for transportation management.

Kuncheria, Anu↗

Micro- & Nano-Technology: A Critical Design Key in Advanced Thermoelectric Cooling Systems

Advanced, thermoelectric cooling technologies now are receiving more research attention to provide cooling in advanced vehicles and residential systems to assist in increasing overall system energy efficiency and reduce greenhouse gas impacts from leakage by current R-134a systems. This work explores the systems-related impacts, barriers, and challenges of using micro-technology solutions integrated with advances in nano-scale thermoelectric materials in advanced TE cooling systems. Integrated system-level analyses that simultaneously account for thermal energy transport into / dissipation out of the TE device, environmental effects, temperature-dependent TE and thermo-physical properties, thermal losses, and thermal and electrical contact resistances are presented to establish accurate optimum system designs using both BixSb2-xTe3 / Bi2Te3 TE systems and Bi2Te3 TE systems. This work established the design trends and identified optimum design regimes and metrics for these types of systems that will minimize system mass, volume and cost to maximize their commercialization potential in vehicular and residential applications. The relationships between important design metrics, like coefficient of performance, specific cooling capacity and cooling heat flux requirements, upper limits, and critical differences in these metrics in BixSb2-xTe3 / Bi2Te3 TE systems and Bi2Te3 TE systems are explored and quantified. Finally, the work discusses the critical role that micro-technologies and nano-technologies can play in enabling miniature TE cooling systems in advanced vehicle and residential applications and gives some key relevant examples.

36 MATERIALS SCIENCE↗