Search NASA⌕ Search

SEARCH · Search NASA

Results for “Vibration Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Integrating Oil Debris and Vibration Measurements for Intelligent Machine Health Monitoring

A diagnostic tool for detecting damage to gears was developed. Two different measurement technologies, oil debris analysis and vibration were integrated into a health monitoring system for detecting surface fatigue pitting damage on gears. This integrated system showed improved detection and decision-making capabilities as compared to using individual measurement technologies. This diagnostic tool was developed and evaluated experimentally by collecting vibration and oil debris data from fatigue tests performed in the NASA Glenn Spur Gear Fatigue Rig. An oil debris sensor and the two vibration algorithms were adapted as the diagnostic tools. An inductance type oil debris sensor was selected for the oil analysis measurement technology. Gear damage data for this type of sensor was limited to data collected in the NASA Glenn test rigs. For this reason, this analysis included development of a parameter for detecting gear pitting damage using this type of sensor. The vibration data was used to calculate two previously available gear vibration diagnostic algorithms. The two vibration algorithms were selected based on their maturity and published success in detecting damage to gears. Oil debris and vibration features were then developed using fuzzy logic analysis techniques, then input into a multi sensor data fusion process. Results show combining the vibration and oil debris measurement technologies improves the detection of pitting damage on spur gears. As a result of this research, this new diagnostic tool has significantly improved detection of gear damage in the NASA Glenn Spur Gear Fatigue Rigs. This research also resulted in several other findings that will improve the development of future health monitoring systems. Oil debris analysis was found to be more reliable than vibration analysis for detecting pitting fatigue failure of gears and is capable of indicating damage progression. Also, some vibration algorithms are as sensitive to operational effects as they are to damage. Another finding was that clear threshold limits must be established for diagnostic tools. Based on additional experimental data obtained from the NASA Glenn Spiral Bevel Gear Fatigue Rig, the methodology developed in this study can be successfully implemented on other geared systems.

Dempsey, Paula J.↗

Maintaining Flatness of a Large Aperture Potassium Bromide Beamsplitter through Mounting and Vibration

The Composite Infrared Spectrometer (CIRS) instrument on the Cassini Mission launched in October of 1997. The CIRS instrument contains a mid-infrared and a far-infrared interferometer and operates at 170 Kelvin. The mid-infrared interferometer is a Michelson- type Fourier transform spectrometer utilizing a 3 inch diameter potassium bromide beamsplitter/compensator pair. The potassium bromide elements were tested to verify effects of cooldown and vibration prior to integration into the instrument. The instrument was then aligned at ambient temperatures, tested cryogenically and re-verified after vibration. The stringent design optical figure requirements for the beamsplitter and compensator included fabrication errors, mounting stresses and vibration load effects. This paper describes the challenges encountered in mounting the elements to minimize distortion and to survive vibration.

Losch, Patricia↗

Viking orbiter 1975 articulation control actuators

The articulation subsystem actuators were rigorously tested in severe environments. They were operated through temperature ranges from -73 C to +121 C. In each case the temperature rate of change was at maximum. The actuator under test at room temperature was put into a pre-chilled or preheated chamber. Satisfactory performance was obtained throughout this full temperature range and under the temperature shock conditions above. However, at temperatures below -78 C some leakage was experienced through the O-ring seal around the shaft. The actuators were subjected to severe vibration and 500 g shock test with a time duration of 0.0007 seconds. The scan actuator was life tested by operating it from stop to stop through 2,000 cycles with 20,000 start-stop procedures randomly distributed through the 2,000 cycles.

Perkins, G. S.↗

Development of baseline random vibration environment criteria for Shuttle pallet payload subsystems

This paper presents a statistical evaluation of measured random vibration response data obtained from the Office of Space Science-1 (OSS-1) pallet payload. The data were measured during the acoustic test simulation (September 1980) and the ascent phase of the flight of STS-3, Orbiter 102 (launched from the Kennedy Space Center on March 22, 1982). Acoustic test efficiency factors are evaluated based on the Dynamic, Acoustic and Thermal Environments (DATE) instrumentation as the source of the measured vibration data. Test efficiency correction to test data is applied in the extrapolation of non-DATE acoustic test data to increase sample population size for improved statistical evaluation. For baseline criteria evaluation and development, data are grouped in accordance with the payload zone in which the component is mounted.

On, F. J.↗

Development of baseline random vibration criteria for STS pallet payloads

This paper presents a statistical evaluation of measured random vibration response data obtained from the Office of Space Science-1 (OSS-1) pallet payload. The data were measured during the acoustic test simulation (September 1980) and the ascent phase of the flight of STS-3, Orbiter 102 (launched from the Kennedy Space Center on March 22, 1982). Acoustic test efficiency factors are evaluated based on the Dynamic, Acoustic and Thermal Environments (DATE) instrumentation as the source of the measured vibration data. Test efficiency correction to test data is applied in the extrapolation of non-DATE acoustic test data to increase sample population size for improved statistical evaluation. For baseline criteria evaluation and development, data are grouped in accordance with the payload 'zone' in which the component is mounted.

On, F. J.↗

Maintaining Flatness of a Large Aperture Potassium Bromide Beamsplitter Through Mounting and Vibration

The Composite Infrared Spectrometer (CIRS) instrument on the Cassini Mission launched in October of 1997. The CIRS instrument contains a mid-infrared (MIR) and a far-infrared interferometer (FIR) and operates at 170 Kelvin. The MIR is a Michelson Fourier transform spectrometer utilizing a 76 mm (3 inch) diameter potassium bromide beamsplitter and compensator pair. The potassium bromide elements were tested to verify effects of cooldown and vibration prior to integration into the instrument. The instrument was then aligned at ambient temperatures, tested cryogenically and re-verified after vibration. 'Me stringent design optical figure requirements for the beamsplitter and compensator included fabrication errors, mounting stresses and vibration load effects. This paper describes the challenges encountered in mounting the elements to minimize distortion and to survive vibration.

Losch, Patricia↗

Bearing Fault Detection on Wind Turbine Gearbox Vibrations Using Generalized Likelihood Ratio-Based Indicators

Studies in condition monitoring literature often aim to detect rolling element bearing faults because they have one of the biggest shares among defects in turbo machinery. Accordingly, several prognosis and diagnosis methods have been devised to identify fault signatures from vibration signals. A recently proposed method to capture the rolling element bearing degradation provides the groundwork for new indicator families utilizing the generalized likelihood ratio test. This novel approach exploits the cyclostationarity and the impulsiveness of vibration signals independently in order to estimate the most suitable indicators for a given fault. However, the method has yet to be tested on complex experimental vibration signals such as those of a wind turbine gearbox. In this study, the approach is applied to the National Renewable Energy Laboratory Wind Turbine Gearbox Condition Monitoring Round Robin Study data set for bearing fault detection purposes. The data set is measured on an experimental test rig of a wind turbine gearbox; hence the complexity of the vibration signals is similar to a real case. The outcome demonstrates that the proposed method is capable of distinguishing between healthy and damaged vibration signals measured on a complex wind turbine gearbox.

condition monitoring↗

30 cm Drop Modeling

This report documents modeling and analysis of the 30 cm cask drop scenario for spent nuclear fuel (SNF) casks. The 30 cm drop is an important hypothetical dynamic loading scenario for SNF because 10 CFR 71.71 defines testing requirements for normal conditions of transport (NCT) of SNF packages, and free drop (of 30 cm for the heaviest packages) tests are required. Other NCT conditions specified in 10 CFR 71.71 include vibration normally incident to transport, and DOE’s multimodal transportation test (MMTT) and related analysis concluded that mechanical shock and vibration incident to transportation is negligible for SNF structural integrity because the loads are so small. The SNF cask 30 cm drop has a lot more potential to cause damage to SNF because the kinetic energy and momentum of the system is stopped abruptly during the cask impact event. Test data and model predictions both agree that the SNF assemblies are subjected to significantly higher loads in a cask drop event than normal transportation shock and vibration, but currently there is no reason to expect gross structural damage of the fuel assembly or widespread SNF cladding failure as a result of a 30 cm cask drop. The ultimate goal of this work is to close the knowledge gap of stress profiles on SNF rods and fuel assembly components during NCT, and this report describes the progress toward reaching that goal as well as a plan for finishing this work over the next year or two. Key remaining tasks include refining the fuel assembly model, calculating a selection of specific fuel assembly cases to populate the damage model, and finally running the damage model to predict the full general response range of 30 cm drop loads on SNF.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Pulsed plasma microthruster for synchronous meteorological satellite /SMS/

Two completely self contained variable thrust flight prototype plasma propulsion systems using solid teflon as propellant were designed, built and laboratory tested. The impulse bit amplitude of each thruster is 25 micro lb-sec. Impulse bits can be provided at rates varying from 50 ppm to 110 ppm. The total impulse capability is 400 lb-sec. Only 23 watts of bus power are required at maximum pulse rate. The system was subjected and passed the required vibration schedule and thermal vacuum test after a minor change in capacitor end face material. A 13 million discharge life test of the system was subsequently performed.

Guman, W. J.↗

Mu2e transport solenoid prototype tests results

The Fermilab Mu2e experiment has been developed to search for evidence of charged lepton flavor violation through the direct conversion of muons into electrons. The transport solenoid is an s-shaped magnet which guides the muons from the source to the stopping target. It consists of fifty-two superconducting coils arranged in twenty-seven coil modules. A full-size prototype coil module, with all the features of a typical module of the full assembly, was successfully manufactured by a collaboration between INFN-Genoa and Fermilab. The prototype contains two coils that can be powered independently. In order to validate the design, the magnet went through an extensive test campaign. Warm tests included magnetic measurements with a vibrating stretched wire, electrical and dimensional checks. As a result, the cold performance was evaluated by a series of power tests as well as temperature dependence and minimum quench energy studies.

43 PARTICLE ACCELERATORS↗

Design of a D-Strut and its application results in the JPL, MIT, and LaRC test beds

High damping at very low magnitudes of vibration is provided by an 'Arched Flexure' D-Strut. Five of these devices have been incorporated in JPL's CSI truss structure, and five more in MIT's interferometer test bed. Two were also temporarily installed in the LaRC CSI test structure. Damping factors in the 50 percent category are being provided at vibration motions as small as 50 nm. The 'Arched Flexure' used in the D-Strut maximizes the volumetric stiffness parameter relative to its axial stiffness. In turn, this enables high damping factors, even in a very rigid truss structure. This paper includes a presentation and discussion of both element and system test data taken at JPL, LaRC, and MIT. Also provided is a detailed description of the D-Strut, the dynamic model, and several graphs showing design parameter variations that will make it possible to evaluate the D-Strut for other applications.

Davis, L. P.↗

Calibration of high-temperature, fiber-optic, microbend, pressure transducers

The microbend pressure transducer was evaluated on the basis of a series of specified tests to determine the pressure, temperature, overpressure, and vibration response. The response was found to be approximately linear with a pressure in the range of -690 to + 690 kPa. The transducer exhibited high sensitivity to diaphragm deflection and rapid response to pressure changes and was insensitive to vibration for frequencies of 50 to 2500 Hz. The microbend transducer test data showed acceptable sensitivity and stability as a function of temperature and pressure to be used as the basis for a compensatable transducer.

Berthold, J. W.↗

20V, 40 Ah Lithium Ion Polymer Battery for the Spacesuit

Objective: Consider a new battery design for EMU. Results: a) Electrovaya s aerospace cell production line is improving, but must further improve to achieve acceptable reliability; b) Completed functional, vibration, and thermal cycling of LIB; c) So far, electrical safety tests have produced good results; d) Completed functional, vibration, thermal cycling, power quality and EMI of LIB Charger; e) Completed CDR on 9/23/04; and f) Manufacturing Readiness Review for flight cell/battery production scheduled for Dec 04.

Darcy, Eric↗

Section 1. Method of determining mode shapes and natural frequencies of the NASA unmodified test structure. Section 2. Continuous beam closed from solution to the NASA-LSS astromast torsional vibration, appendix E

The methods used to determine the lower natural frequencies and their corresponding mode shapes of the NASA-LSS Astromast (Unmodified Test Structure), and the mass integrals associated with the mode shapes are illustrated. The test structure is modeled as a cantilever beam with 91 lumped masses and without the tip mass on the free end of the bram. This uncouples the torsion and bending modes and allows for them to be determined separately. The frequency range was limited to an upper bound of 100 rad/sec (15.92 Hz.). In this range from 0.-100. rad/sec, three bending frequencies and one torsion frequency was found.

Source record↗

Tiltrotor Vibration Reduction Through Higher Harmonic Control

The results of a joint NASA/Army/Bell Helicopter Textron wind-tunnel test to assess the potential of higher harmonic control (HHC) for reducing vibrations in tiltrotor aircraft operating in the airplane mode of flight, and to evaluate the effectiveness of a Bell-developed HHC algorithm called MAVSS (Multipoint Adaptive Vibration Suppression System) are presented. The test was conducted in the Langley Transonic Dynamics Tunnel using an unpowered 1/5-scale semispan aeroelastic model of the V-22 which was modified to incorporate an HHC system employing both the rotor swashplate and the wing flaperon. The effectiveness of the swashplate and the flaperon acting either singly or in combination in reducing IP and 3P wing vibrations over a wide range of tunnel airspeeds and rotor rotational speeds was demonstrated. The MAVSS algorithm was found to be robust to variations in tunnel airspeed and rotor speed, requiring only occasional on-line recalculations of the system transfer matrix. HHC had only a small (usually beneficial) effect on blade loads but increased pitch link loads by 25%. No degradation in aeroelastic stability was noted for any of the conditions tested.

Nixon, Mark W.↗

Fluidization and drying of biomass particles in a vibrating fluidized bed with pulsed gas flow

Fluidization of biomass particles in the absence of inert bed materials has been tested in a pulsed fluidized bed with vibration, with the pulsation frequency ranging from 033 to 6.67 Hz. Intermittent fluidization at 033 Hz and apparently 'normal' fluidization at 6.67 Hz with regular bubble patterns were observed. Pulsation has proven to be effective in overcoming the bridging of irregular biomass particles induced by strong inter-particle forces. The vibration is only effective when the pulsation is inadequate, either at too low a frequency or too low in amplitude. We dried biomass in order to quantify the effectiveness of gas pulsation for fluidized bed dryers and torrefiers in terms of gas-solid contact efficiency and heat and mass transfer rates. Furthermore, the effects of gas flow rate, bed temperature, pulsation frequency and vibration intensity on drying performance have been systematically investigated. While higher temperature and gas flow rate are favored in drying, there exists an optimal range of pulsation frequency between 0.75 Hz and 1.5 Hz where gas-solid contact is enhanced in both the constant rate drying and falling rate drying periods.

09 BIOMASS FUELS↗

Evaluation testing of solid encapsulated microcircuits for space applications

Epoxy encapsulated microcircuits were subjected to various thermal, vibration, thermal cycling, and reduced barometric pressure stress tests to obtain electrical, environmental, and failure data. Analyses of the data were employed to derive information on environmental and operating design limits to determine the capability of encapsulated microcircuits to perform in space applications and environments. Seven different part types (four TTL, two CMOS, one linear) from five different manufacturers were subjected to single, multiple, and combinational environmental stress levels to determine: (1) what failure mechanisms are unique to encapsulated microcircuits; (2) how believable are suppliers claims of improved reliability, (3) what stress tests and screens can be used to identify potential early failure, and (4) what stress tests and screens should be avoided to prevent unwanted life degradation.

Robinson, D. D.↗

Environmental Test Screening Procedure

This procedure describes the methods to be used for environmental stress screening (ESS) of the Lightning Mapper Sensor (LMS) lens assembly. Unless otherwise specified, the procedures shall be completed in the order listed, prior to performance of the Acceptance Test Procedure (ATP). The first unit, S/N 001, will be subjected to the Qualification Vibration Levels, while the remainder will be tested at the Operational Level. Prior to ESS, all units will undergo Pre-ESS Functional Testing that includes measuring the on-axis and plus or minus 0.95 full field Modulation Transfer Function and Back Focal Length. Next, all units will undergo ESS testing, and then Acceptance testing per PR 460.

Zeidler, Janet↗