Search NASA⌕ Search

SEARCH · Search NASA

Results for “plane of array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Prototype Magnetic Calorimeter Arrays with Buried Wiring for the Lynx X-Ray Microcalorimeter

Metallic magnetic calorimeter (MMC) technology is a leading contender for detectors for the Lynx X-ray Microcalorimeter, which is an imaging spectrometer consisting of an array of greater than 100,000 pixels. The fabrication of such large arrays presents a challenge when attempting to route the superconducting wiring from the pixels to the multiplexed readout. If the wiring is designed to be planar, then an aggressive, submicron scale wiring pitch has to be employed, which is technically challenging to design and fabricate on account of the requirements of low inductance, low cross-talk, high critical currents and high yield. An alternative way to achieve large scale, high density wiring is through the use of multiple buried metal layers, planarized by Chemical Mechanical Planarization. This approach is well-suited for connecting thousands of pixels on a large focal plane to readout chips, and also for fabricating sensor meander coils with narrow line widths, which helps in increasing the sensor inductance and thus alleviates stray inductance issues associated with the wiring in large size arrays. In this work we describe the fabrication of high sensor inductance MMC arrays implementing Lynx concepts and incorporating multiple layers of buried Nb wiring. The detector array is composed of three sub-arrays with pixels optimized to meet the different science driven performance requirements of Lynx. In two of the sub-arrays we adopt a thermal multiplexing scheme to read out pixels by coupling 25 absorbers to a single sensor through thermal links of varied thermal conductance. We demonstrate the successful fabrication of multi-absorber MMCs with fine pitch pixels in very large size arrays.

Solid-State Physics↗

Coupled modeling of wake steering and platform offsets for floating wind arrays

Wake effects are a key challenge in the design and analysis of wind farms. For floating wind farms, the platforms offset under the aerodynamic loading of the turbine and are constrained by mooring systems that can vary significantly in allowable offsets. When considering wake steering, the crosswind offset of the turbine can counteract the lateral deflection of the wake. This work presents a tool to efficiently model the coupled impacts of wake steering and platform offsets for floating wind farms. The tool relies on the frequency-domain wind farm model RAFT and the steady-state wake model FLORIS. A verification with FAST.Farm is presented, then the tool is applied to a simple two-turbine case study. A range of mooring systems with increasing platform offsets and varied yaw misalignment angles are considered while comparing the impact on turbine power. Additional sensitivities to turbine spacing and mooring system orientation are explored. The results show that there is a least-optimal watch circle width for downwind turbine power production that varies with yaw misalignment angle and turbine spacing. Additionally, the turbine offsets under yaw-misaligned conditions vary significantly depending on mooring system orientation relative to the rotor plane, which in turn impacts the optimal misalignment angle. These results highlight the importance of including floating platform offsets and mooring systems in the evaluation of wake steering strategies for floating wind arrays.

17 WIND ENERGY↗

Cosmic Background Explorer (COBE) transfer orbit attitude control system

The Cosmic Background Explorer (COBE) spacecraft will be launched by the Shuttle from Vandenberg AFB into a 300 km altitude, 99 deg inclination, 6 a.m. or 6 p.m. ascending node orbit. After release from the Remote Manipulator System (RMS) arm, an on-board monopropellant hydrazine propulsion system will raise the orbit altitude to 900 km. The spacecraft continuously spins during transfer orbit operations with the spin axis nominally horizontal and in or near the orbit plane. The blowdown propulsion system consists of twelve 5 lb thrusters (3 'spin', 3 'despin', and 6 'axial') with the latter providing initially 30 lb of force parallel to the spin axis for orbit raising. The spin/despin jets provide a constant roll rate during the transfer orbit phase of the mission and the axials control pitch and yaw. The axial thrusters are pulsed on for attitude control during coast periods and are normally on- and off-modulated for control during orbit raising. Attitude sensors employed in the control loops include an array of two-axis digital sun sensors and three planar earth scanners for position measurements, as well as six gyroscopes for rate information. System redundancy is achieved by means of unique three-axes-in-a-plane geometry. This triaxial concept results in a fail-safe operational system with no performance degradation for many different component failure modes.

Placanica, Samuel J.↗

On Orbit Flight Testing of the Roll-Out Solar Array

The Roll-Out Solar Array (ROSA) is an innovative, lightweight solar array with a flexible substrate that makes use of the stored strain energy in its composite structural members to provide deployment without the use of motors while still packaging efficiently. The ROSA flight experiment was launched to the International Space Station (ISS)on June 3rd, 2017 as a part of the eleventh SpaceX commercial resupply mission. After two weeks of storage, ROSA was extracted from the Dragon spacecraft, deployed, and put through a week of tests to verify its structural characteristics as well as the performance of photovoltaics. The structural dynamics experiments included active excitation of out-of-plane bending modes, and a study of the thermal-structural interaction of the structure during day-night transitions. Data was gathered from a small number of accelerometers located at key points on the solar array and from cameras observing numerous photogrammetry targets spread out over the structure and the photovoltaic blanket. The goal in this effort was to better understand the performance of ROSA and to improve modeling efforts for future designs of similar solar arrays. Of particular interest are the first few system modes and mode shapes of the array, the amount of structural damping present, and degree of structural-thermal interaction seen during eclipse exit.

ROSA↗

In x Ga 1- x As Nanowires on Silicon: One-Dimensional Heterogeneous Epitaxy, Bandgap Engineering, and Photovoltaics

We report on the one-dimensional (1D) heteroepitaxial growth of In x Ga 1-x As (x = 0.2–1) nanowires (NWs) on silicon (Si) substrates over almost the entire composition range using metalorganic chemical vapor deposition (MOCVD) without catalysts or masks. The epitaxial growth takes place spontaneously producing uniform, nontapered, high aspect ratio NW arrays with a density exceeding 1 × 10 8 /cm 2 . NW diameter (~30–250 nm) is inversely proportional to the lattice mismatch between In x Ga 1-x As and Si (~4–11%), and can be further tuned by MOCVD growth condition. Remarkably, no dislocations have been found in all composition In x Ga 1-x As NWs, even though massive stacking faults and twin planes are present. Indium rich NWs show more zinc-blende and Ga-rich NWs exhibit dominantly wurtzite polytype, as confirmed by scanning transmission electron microscopy (STEM) and photoluminescence spectra. Solar cells fabricated using an n-type In 0.3 Ga 0.7 As NW array on a p-type Si(111) substrate with a ~ 2.2% area coverage, operates at an open circuit voltage, V oc , and a short circuit current density, J sc , of 0.37 V and 12.9 mA/cm 2 , respectively. Furthermore, this work represents the first systematic report on direct 1D heteroepitaxy of ternary In x Ga 1-x As NWs on silicon substrate in a wide composition/bandgap range that can be used for wafer-scale monolithic heterogeneous integration for high performance photovoltaics.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

An in situ GISAXS study of selective solvent vapor annealing in thin block copolymer films: Symmetry breaking of in‐plane sphere order upon deswelling

ABSTRACT Thin films of asymmetric poly(styrene‐ b ‐4‐vinylpyridine) (PS‐ b ‐P4VP) block copolymers are studied by means of in situ grazing‐incidence small‐angle X‐ray scattering (GISAXS) during solvent vapor annealing in tetrahydrofuran, a solvent selective for the PS majority block of the copolymer. Upon swelling, PS‐ b ‐P4VP block copolymers form hexagonal arrays of spherical P4VP microdomains in a PS matrix in films 7–9 layers thick. Deswelling the films induces a transition from hexagonal to face‐centered orthorhombic (fco) symmetry, which is stable only at ∼7 layers of spherical microdomains. Dry films show co‐existing hexagonal and orthorhombic symmetries when the solvent is removed slowly, whereas instantaneous solvent removal suppresses the fco structure, resulting in films with only hexagonal structure. The in‐plane order of microdomains is significantly deteriorated in dry films independent of the solvent removal rate.Spherical block copolymer microdomains are known to undergo a transition from hexagonal to orthorhombic packing in isothermally annealed thin films when the number of sphere layers is increased from 4 to 5. In this paper, in situ GISAXS experiments reveal that a similar transition occurs during solvent vapor annealing in a selective solvent. Interestingly, the transition from hexagonal to orthorhombic packing of spheres occurs as solvent is removed from a thin block copolymer film. © 2015 Wiley Periodicals, Inc. J. Polym. Sci., Part B: Polym. Phys. 2016, 54, 331–338

Gunkel, Ilja↗

Characterization of a novel 2D array dosimeter for patient-specific quality assurance with volumetric arc therapy

Purpose: In this study, the authors are evaluating a new, commercially available 2D array that offers 3D dose reconstruction for patient specific intensity modulated radiation therapy quality assurance (IMRT QA).Methods: The OCTAVIUS 4D system and its accompanying software (VERISOFT) by PTW were evaluated for the accuracy of the dose reconstruction for patient specific pretreatment IMRT QA. OCTAVIUS 4D measures the dose plane at the linac isocenter as the phantom rotates synchronously with the gantry, maintaining perpendicularity with the beam, by means of an inclinometer and a motor. The measurements collected during a volumetric modulated arc therapy delivery (VMAT) are reconstructed into a 3D dose volume. The VERISOFT application is used to perform the analysis, by comparing the reconstructed dose against the 3D dose matrix from the treatment planning system (TPS) that is computed for the same geometry and beam arrangement as that of the measurement. In this study, the authors evaluated the 3D dose reconstruction algorithm of this new system using a series of tests. Using the Octavius 4D phantom as the patient, dose distributions for various field sizes, beam orientations, shapes, and combination of fields were calculated using the Pinnacle3, TPS, and the respective DICOMRT dose was exported to the VERISOFT analysis software. Measurements were obtained by delivering the test treatment plans and comparisons were made based on gamma index, dose profiles, and isodose distribution analysis. In addition, output factors were measured and the dose linearity of the array was assessed. Those measurements were compared against measurements in water using a single, calibrated ionization chamber as well as calculations from Pinnacle for the same delivery geometries.Results: The number of voxels that met the 3%/3 mm criteria for the volumetric 3D gamma index analysis ranged from 92.3% to 98.9% for all the patient plans that the authors evaluated. 2D gamma analysis in the axial, sagittal, and coronal planes produced similar results to those in the 3D gamma analysis. The new detector system does not require an angular dependence correction because it rotates in synchrony with the gantry and the detector array maintains a constant SAD while always perpendicular to the beam axis. Output factors were within 2% when compared to ionization chamber measurements and Pinnacle calculations. Similar agreement was observed when testing the MU linearity (for MU values above 2) as well as dose rate effect.Conclusions: The OCTAVIUS 4D system has some unique characteristics that can potentially improve the patient specific pretreatment IMRT QA data collection and analysis. The ability of the software to reconstruct from the measurements the true 3D dose distribution in the phantom, provides a unique perspective for the medical physicist that evaluates a patient's QA plan.

61 RADIATION PROTECTION AND DOSIMETRY↗

Towards combining in-beam {gamma}-ray and conversion electron spectroscopy

The SAGE spectrometer will combine a segmented Si-detector with a Ge-detector array aiming to take the simultaneous in-beam {gamma}-ray and conversion electron spectroscopy to the next level. It will be coupled with the GREAT focal plane spectrometer and the RITU gas-filled recoil separator at the accelerator laboratory of the University of Jyvaeskylae, Finland. Its high efficiency and resolution will open the door to a new era of complete spectroscopy directed, amongst others, at the study of superheavy nuclei aiming to investigate the properties of the next spherical proton shell above Z = 82.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

THE MAGNETIC FIELD IN THE NGC 2024 FIR 5 DENSE CORE

We used the Submillimeter Array to observe the thermal polarized dust emission from the protostellar source NGC 2024 FIR 5. The polarized emission outlines a partial hourglass morphology for the plane-of-sky component of the core magnetic field. Our data are consistent with previous BIMA maps, and the overall magnetic field geometries obtained with both instruments are similar. We resolve the main core into two components, FIR 5A and FIR 5B. A possible explanation for the asymmetrical field lies in depolarization effects due to the lack of internal heating from the FIR 5B source, which may be in a prestellar evolutionary state. The field strength was estimated to be 2.2 mG, in agreement with previous BIMA data. We discuss the influence of a nearby H II region over the field lines at scales of {approx}0.01 pc. Although the hot component is probably compressing the molecular gas where the dust core is embedded, it is unlikely that the radiation pressure exceeds the magnetic tension. Finally, a complex outflow morphology is observed in CO (3 {yields} 2) maps. Unlike previous maps, several features associated with dust condensations other than FIR 5 are detected.

79 ASTRONOMY AND ASTROPHYSICS↗

CANGAROO-III OBSERVATION OF TeV GAMMA RAYS FROM THE UNIDENTIFIED GAMMA-RAY SOURCE HESS J1614-518

We report the detection, with the CANGAROO-III imaging atmospheric Cherenkov telescope array, of a very high energy gamma-ray signal from the unidentified gamma-ray source HESS J1614-518, which was discovered in the H.E.S.S. Galactic plane survey. Diffuse gamma-ray emission was detected above 760 GeV at the 8.9{sigma} level during an effective exposure of 54 hr from 2008 May to August. The spectrum can be represented by a power law: (8.2 {+-} 2.2{sub stat} {+-} 2.5{sub sys}) x 10{sup -12} x (E/1 TeV){sup -}{gamma} cm{sup -2} s{sup -1} TeV{sup -1} with a photon index {gamma} of 2.4 {+-} 0.3{sub stat} {+-} 0.2{sub sys}, which is compatible with that of the H.E.S.S. observations. By combining our result with multiwavelength data, we discuss the possible counterparts for HESS J1614-518 and consider radiation mechanisms based on hadronic and leptonic processes for a supernova remnant (SNR), stellar winds from massive stars, and a pulsar wind nebula (PWN). Although a leptonic origin from a PWN driven by an unknown pulsar remains possible, hadronic-origin emission from an unknown SNR is preferred.

79 ASTRONOMY AND ASTROPHYSICS↗

A METHOD TO SEARCH FOR CORRELATIONS OF ULTRA-HIGH ENERGY COSMIC-RAY MASSES WITH THE LARGE-SCALE STRUCTURES IN THE LOCAL GALAXY DENSITY FIELD

One of the main goals of investigations using present and future giant extensive air shower (EAS) arrays is the mass composition of ultra-high energy cosmic rays (UHECRs). A new approach to the problem is presented, combining the analysis of arrival directions with the statistical test of the paired EAS samples. One of the ideas of the method is to search for possible correlations between UHECR masses and their separate sources; for instance, if there are two sources in different areas of the celestial sphere injecting different nuclei, but the fluxes are comparable so that arrival directions are isotropic, then the aim is to reveal a difference in the mass composition of cosmic-ray fluxes. The method is based on a non-parametric statistical test-the Wilcoxon signed-rank routine-which does not depend on the populations fitting any parameterized distributions. Two particular algorithms are proposed: first, using measurements of the depth of the EAS maximum position in the atmosphere; and second, relying on the age variance of air showers initiated by different primary particles. The formulated method is applied to the Yakutsk array data, in order to demonstrate the possibility of searching for a difference in average mass composition between the two UHECR sets, arriving particularly from the supergalactic plane and a complementary region.

79 ASTRONOMY AND ASTROPHYSICS↗

Quality factor assessment of finite-size all-dielectric metasurfaces at the magnetic dipole resonance

Recently there has been a large interest in achieving metasurface resonances with large quality factors. In this article, we examine metasurfaces that comprised a finite number of magnetic dipoles oriented parallel or orthogonal to the plane of the metasurface and determine analytic formulas for their resonances’ quality factors. These conditions are experimentally achievable in finite-size metasurfaces made of dielectric cubic resonators at the magnetic dipole resonance. Our results show that finite metasurfaces made of parallel (to the plane) magnetic dipoles exhibit low quality factor resonances with a quality factor that is independent of the number of resonators. More importantly, finite metasurfaces made of orthogonal (to the plane) magnetic dipoles lead to resonances with large quality factors, which ultimately depend on the number of resonators comprising the metasurface. In particular, by properly modulating the array of dipole moments by having a distribution of resonator polarizabilities, one can potentially increase the quality factor of metasurface resonances even further. These results provide design guidelines to achieve a sought quality factor applicable to any resonator geometry for the development of new devices such as photodetectors, modulators, and sensors.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Improved sensitivity gas detection by spontaneous Raman scattering

Accurate, real-time measurement of the dilute constituents of a gaseous mixture poses a significant challenge usually relegated to mass spectrometry. Here, spontaneous Raman backscattering is used to detect low pressure molecular gases. Rapid detection of gases in the 100 parts in 106 ðppmÞ range is described. Improved sensitivity is brought about by use of a hollow-core, photonic bandgap fiber gas cell in the backscattering configuration to increase collection efficiency and an image-plane aperture to greatly reduce silica-Raman background noise. Spatial and spectral properties of the silica noise were examined with a two-dimensional CCD detector array

99 GENERAL AND MISCELLANEOUS↗

Active Well Counting Using New PSD Plastic Detectors

This report presents results and analysis from a series of proof-of-concept measurements to assess the suitability of segmented detectors constructed from Eljen EJ-299-34 PSD-plastic scintillator with pulse-shape discrimination capability for the purposes of quantifying uranium via active neutron coincidence counting. Present quantification of bulk uranium materials for international safeguards and domestic materials control and accounting relies on active neutron coincidence counting systems, such as the Active Well Coincidence Counter (AWCC) and the Uranium Neutron Coincidence Collar (UNCL), that use moderated He-3 proportional counters along with necessarily low-intensity 241Am(Li) neutron sources. Scintillation-based fast-neutron detectors are a potentially superior technology to the existing AWCC and UNCL designs due to their spectroscopic capability and their inherently short neutron coincidence times that largely eliminate random coincidences and enable interrogation by stronger sources. One of the past impediments to the investigation and adoption of scintillation counters for the purpose of quantifying bulk uranium was the commercial availability of scintillators having the necessary neutron-gamma pulse-shape discrimination properties only as flammable liquids. Recently, Eljen EJ-299-34 PSD-plastic scintillator became commercially available. The present work is the first assessment of an array of PSD-plastic detectors for the purposes of quantifying bulk uranium. The detector panel used in the present work was originally built as the focal plane for a fast-neutron imager, but it was repurposed for the present investigation by construction of a stand to support the inner well of an AWCC immediately in front of the detector panel. The detector panel and data acquisition of this system are particularly well suited for performing active-well fast-neutron counting of LEU and HEU samples because the active detector volume is solid, the 241Am(Li) interrogating neutrons are largely below the detector threshold, and the segmented construction of the detector modules allow for separation of true neutron-neutron coincidences from inter-detector scattering using the kinematics of neutron scattering. The results from a series of measurements of a suite of uranium standards are presented, and compared to measurements of the same standards and source configurations using the AWCC. Using these results, the performance of the segmented detectors reconfigured as a well counter is predicted and outperforms the AWCC.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The Southern H ii Region Discovery Survey (SHRDS): Pilot Survey

The Southern H ii Region Discovery Survey is a survey of the third and fourth quadrants of the Galactic plane that will detect radio recombination line (RRL) and continuum emission at cm-wavelengths from several hundred H ii region candidates using the Australia Telescope Compact Array. The targets for this survey come from the WISE Catalog of Galactic H ii Regions and were identified based on mid-infrared and radio continuum emission. In this pilot project, two different configurations of the Compact Array Broad Band receiver and spectrometer system were used for short test observations. The pilot surveys detected RRL emission from 36 of 53 H ii region candidates, as well as seven known H ii regions that were included for calibration. These 36 recombination line detections confirm that the candidates are true H ii regions and allow us to estimate their distances.

79 ASTRONOMY AND ASTROPHYSICS↗

Flow conditions around the exit and downstream of certain stator blading with various trailing edge thicknesses and geometries

The blading investigated was curved back with thick profiles. The variations in flow conditions considered were flow angle and isentropic energy. Experimental data were obtained in a two-dimensional cascade from surveys with a combined angle, total-, and static-pressure probe and from an array of end-wall static pressure taps. Analytical results were obtained from ideal flow theory. The results showed large variations in flow conditions close to the plane of the trailing edge that were largely attenuated at a distance a little greater than one blade pitch downstream of the trailing edge in the direction of flow. The results were affected by the geometry and thickness of the trailing edge. The agreement between experimental and analytical results is generally fair to excellent.

Prust, H. W., Jr.↗

Partially confined multiple jet mixing

Results of hot-wire measurements in an incompressible partially confined jet issuing from an array of rectangular nozzles, equally spaced with their small dimensions aligned are presented. The quantities measured include mean velocity and the Reynolds stress in the two central planes of the jet at stations covering up to 115 widths (small dimension of a nozzle) downstream of the nozzle exit. For downstream distances greater than 60 widths, the flowfield is observed to be nearly homogenous and the turbulence appears to be quite similar to that of a grid generated turbulence.

Krothapalli, A.↗

A study of a collision avoidance system mounted on a curved ground plane

Research conducted on a traffic advisory and collision avoidance system (TCAS 2) mounted on a curved ground plane is described. It is found that a curved finite ground plane can be used as a good simulation model for the fuselage of an aircraft but may not be good enough to model a whole aircraft due to the shadowing of the vertical stabilizer, wings, etc. The surface curvature of this curved disc significantly affects the monopulse characteristics in the azimuth plane but not as much in the elevation plane. These variations of the monopulse characteristics verify the need of a lookup table for the 64 azimuth beam positions. The best location of a TCAS 2 array on a Boeing 737 is to move it as far from the vertical stabilizer as possible.

Law, P. H.↗