Search NASA⌕ Search

SEARCH · Search NASA

Results for “study protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Impact of imaging protocol on left ventricular ejection fraction using gated-SPECT myocardial perfusion imaging

Background: There are limited data on the impact of the imaging protocol (single-day stress-rest, SD, vs. dual-day, DD) on the change in left ventricular (LV) ejection fraction (EF) (post-stress-rest) in relation to ischemia and on outcome. Methods: Using propensity score matching procedure, 490 of 1121 patients with known CAD, undergoing a SD or a DD in a multicenter study, were evaluated. Stress and rest gated-SPECT myocardial perfusion imaging was used to quantify LV perfusion, EF, and volumes. Outcome was assessed at an average follow-up time of 3.2 years. Results: Post-stress LVEF in SD and DD were comparable across all degrees of ischemia. The change in LVEF in patients with severe ischemia was, however, higher in the DD protocol, independent of the extent of CAD. At follow-up, 240 patients (49.0%) required coronary revascularization (CR) and 52 patients (10.6%) had hard events. The ischemic burden was independently associated with CR and hard-events; the post-stress LVEF was associated with CR but the change in EF was not predictive of either CR or hard events. Conclusions: In patients with severe ischemia, underestimation of post-stress myocardial stunning could be observed with the SD protocol. Post-stress LVEF and the extent ischemia, but not the change in EF, are predictive of CR and hard events.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Exploratory Study for Continuous-time Parameter Estimation of Ankle Dynamics

Recently, a parallel pathway model to describe ankle dynamics was proposed. This model provides a relationship between ankle angle and net ankle torque as the sum of a linear and nonlinear contribution. A technique to identify parameters of this model in discrete-time has been developed. However, these parameters are a nonlinear combination of the continuous-time physiology, making insight into the underlying physiology impossible. The stable and accurate estimation of continuous-time parameters is critical for accurate disease modeling, clinical diagnosis, robotic control strategies, development of optimal exercise protocols for longterm space exploration, sports medicine, etc. This paper explores the development of a system identification technique to estimate the continuous-time parameters of ankle dynamics. The effectiveness of this approach is assessed via simulation of a continuous-time model of ankle dynamics with typical parameters found in clinical studies. The results show that although this technique improves estimates, it does not provide robust estimates of continuous-time parameters of ankle dynamics. Due to this we conclude that alternative modeling strategies and more advanced estimation techniques be considered for future work.

neuromuscular systems↗

Prospective Study of Cone-Beam Computed Tomography Image-Guided Radiotherapy for Prone Accelerated Partial Breast Irradiation

Purpose: To report setup variations during prone accelerated partial breast irradiation (APBI). Methods: New York University (NYU) 07-582 is an institutional review board-approved protocol of cone-beam computed tomography (CBCT) to deliver image-guided ABPI in the prone position. Eligible are postmenopausal women with pT1 breast cancer excised with negative margins and no nodal involvement. A total dose of 30 Gy in five daily fractions of 6 Gy are delivered to the planning target volume (the tumor cavity with 1.5-cm margin) by image-guided radiotherapy. Patients are set up prone, on a dedicated mattress, used for both simulation and treatment. After positioning with skin marks and lasers, CBCTs are performed and the images are registered to the planning CT. The resulting shifts (setup corrections) are recorded in the three principal directions and applied. Portal images are taken for verification. If they differ from the planning digital reconstructed radiographs, the patient is reset, and a new CBCT is taken. Results: 70 consecutive patients have undergone a total of 343 CBCTs: 7 patients had four of five planned CBCTs performed. Seven CBCTs (2%) required to be repeated because of misalignment in the comparison between portal and digital reconstructed radiograph image after the first CBCT. The mean shifts and standard deviations in the anterior-posterior (AP), superior-inferior (SI), and medial-lateral (ML) directions were -0.19 (0.54), -0.02 (0.33), and -0.02 (0.43) cm, respectively. The average root mean squares of the daily shifts were 0.50 (0.28), 0.29 (0.17), and 0.38 (0.20). A conservative margin formula resulted in a recommended margin of 1.26, 0.73, 0.96 cm in the AP, SI, and ML directions. Conclusion: CBCTs confirmed that the NYU prone APBI setup and treatment technique are reproducible, with interfraction variation comparable to those reported for supine setup. The currently applied margin (1.5 cm) adequately compensates for the setup variation detected.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Magnetic contributions to corundum-eskolaite and corundum-hematite phase equilibria: A DFT cluster expansion study

Magnetic contributions have the potential to significantly influence predicted phase stability within alloy and mineral mixing phase diagrams, yet have been historically challenging to incorporate due to a significant increase to phase space sampling. Here, in this work, we employ a computational protocol that includes spin orientation as an additional configurational component within multi-component cluster expansions between magnetic and non-magnetic metal oxide alloys [calculated using density functional theory (DFT) and the generalized gradient approximation]. This approach was used to determine the effect of magnetic contributions to corundum-eskolaite and corundum-hematite phase equilibria from first principles. Two-component cluster expansions of the magnetic components of eskolaite and hematite were first performed showing the ability of this method to properly calculate their respective magnetic properties. Two-component cluster expansions were then performed for non-magnetic Al(III) and ferromagnetic Cr(III) and Fe(III), and phase diagrams were calculated for later comparison. Finally, a non-magnetic Al(III) and “up” and “down” magnetic configurations for anti-ferromagnetic Cr(III) and Fe(III) were performed. Magnetic contributions to the calculated phase diagram for the corundumeskolaite system were shown to be inconsequential but are vital for accurate determination of the corundum-hematite solvus.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Clinical Development of Molecularly Targeted Agents in Combination With Radiation Therapy: A Pharmaceutical Perspective

Summary: This paper explores historical and current roles of pharmaceutical industry sponsorship of clinical trials testing radiation therapy combinations with molecularly targeted agents and attempts to identify potential solutions to expediting further combination studies. An analysis of clinical trials involving a combination of radiation therapy and novel cancer therapies was performed. Ongoing and completed trials were identified by searching the (clinicaltrials.gov) Web site, in the first instance, with published trials of drugs of interest identified through American Society of Clinical Oncology, European CanCer Organisation/European Society for Medical Oncology, American Society for Radiation Oncology/European Society for Therapeutic Radiology and Oncology, and PubMed databases and then cross-correlated with (clinicaltrials.gov) protocols. We examined combination trials involving radiation therapy with novel agents and determined their distribution by tumor type, predominant molecular mechanisms examined in combination to date, timing of initiation of trials relative to a novel agent's primary development, and source of sponsorship of such trials. A total of 564 studies of targeted agents in combination with radiation therapy were identified with or without concomitant chemotherapy. Most studies were in phase I/II development, with only 36 trials in phase III. The tumor site most frequently studied was head and neck (26%), followed by non-small cell lung cancer. Pharmaceutical companies were the sponsors of 33% of studies overall and provided support for only 16% of phase III studies. In terms of pharmaceutical sponsorship, Genentech was the most active sponsor of radiation therapy combinations (22%), followed by AstraZeneca (14%). Most radiation therapy combination trials do not appear to be initiated until after drug approval. In phase III studies, the most common (58%) primary endpoint was overall survival. Collectively, this analysis suggests that such trials are not given priority by pharmaceutical companies. The potential reasons for this and some challenges and possible solutions are discussed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A rapid thioacidolysis method for biomass lignin composition and tricin analysis

Abstract Background Biomass composition varies from plant to plant and greatly affects biomass utilization. Lignin is a heterogeneous phenolic polymer derived mainly from p -coumaryl, coniferyl, and sinapyl alcohols and makes up to 10–25% of lignocellulosic biomass. Recently, tricin, an O -methylated flavone, was identified as a lignin monomer in many grass species. Tricin may function as a nucleation site for lignification and is advocated as a novel target for lignin engineering to reduce lignin content and improve biomass digestibility in grasses. Thioacidolysis is an analytical method that can be adapted to analyze both lignin monomeric composition and tricin content in the lignin polymer. However, the original thioacidolysis procedure is complex, laborious, and time consuming, making it difficult to be adopted for large-scale screening in biomass research. In this study, a modified, rapid higher throughput thioacidolysis method was developed. Results In combination with gas chromatography–mass spectrometry (GC–MS) and liquid chromatography–mass spectrometry (LC–MS), the modified thioacidolysis method can be used to simultaneously characterize the lignin composition and tricin content using 2–5 mg of dry samples. The modified method eliminates the solvent extraction and drastically improves the throughput; 80 samples can be processed in one day per person. Our results indicate that there is no significant difference in the determination of lignin S/G ratio and tricin content between the original and modified methods. Conclusions A modified thioacidolysis protocol was established. The results demonstrate that the modified method can be used for rapid, high-throughput, and reliable lignin composition and tricin content analyses for screening transgenic plants for cell wall modifications or in large-scale genome-wide association studies (GWAS).

09 BIOMASS FUELS↗

WE-AB-204-05: Harmonizing PET/CT Quantification in Multicenter Studies: A Case Study

Purpose: To present the implementation of a strategy to harmonize FDG PET/CT quantification (SUV), performed with different scanner models and manufacturers. Methods: The strategy was based on Boellaard (2011) and EARL FDG-PET/CT accreditation program, that propose quality control measurements for harmonizing scanner performance. A NEMA IEC Body phantom study was performed using four different devices: PHP-1 (Gemini TF Base, Philips); PHP-2 (Gemini GXL, Philips); GEH (Discovery 600, General Electric); SMS (Biograph Hi-Rez 16, Siemens). The SUV Recovery Coefficient (RC) was calculated using the clinical protocol and other clinically relevant reconstruction parameters. The most appropriate reconstruction parameters (MARP) for SUV harmonization, in each scanner, are those which achieve EARL harmonizing standards. They were identified using the lowest root mean square errors (RMSE). To evaluate the strategy’s effectiveness, the Maximum Differences (MD) between the clinical and MARP RC values were calculated. Results: The reconstructions parameters that obtained the lowest RMSE are: FBP 5mm (PHP-1); LOR-RAMLA 2i0.008l (PHP-2); VuePointHD 2i32s10mm (GEH); and FORE+OSEM 4i8s6mm (SMS). Thus, to ensure that quantitative PET image measurements are interchangeable between these sites, images must be reconstructed with the above-mentioned parameters. Although, a decoupling between the best image for PET/CT qualitative analysis and the best image for quantification studies was observed. The MD showed that the strategy was effective in reducing the variability of SUV quantification for small structures (<17mm). Conclusion: The harmonization strategy of the SUV quantification implemented with these devices was effective in reducing the variability of small structures quantification, minimizing the inter-scanner and inter-institution differences in quantification. However, it is essential that, in addition to the harmonization of quantification, the standardization of the methodology of patient preparation must be maintained, in order to minimize the SUV variability due to biological factors. Financial support by CAPES.

60 APPLIED LIFE SCIENCES↗

Accelerated test protocols to predict service life and durability of solid oxide fuel cells

Reliable accelerated test protocols are needed for solid oxide fuel cell research to facilitate rapid learning on key durability issues, identify potential modes of failure expeditiously, and eventually predict the calendar lifetime of an electrochemical cell. In this work, solid oxide fuel cells operated at a constant current density were compared to cells undergoing accelerated measurements, which are composed of intermittent current injection to the cell. A general accelerated test profile was developed by cycling a solid oxide fuel cell from open circuit to a predetermined operating current density that is the same as the current density during a steady-state operation, to accelerate the local redox environment. The following parameters were studied: current density, operation temperature, moist level, sintering temperature, cycling current, cycling frequency, and operation time. Up to 1,320,000 cycles were generated in this work. The cell degradation was accelerated by nearly 10 times, suggesting the feasibility of using this protocol for acceleration test to predict life performance and durability of solid oxide fuel cells.

08 HYDROGEN↗

California GAMA Special Study: Excess Nitrogen and Methane in Noble Gas Samples

The most prominent constituent causing concern for drinking water resources in California is nitrate. Denitrification in the unsaturated zone and in groundwater naturally reduces nitrate concentrations, controls the fate of groundwater nitrate and determines the time scale over which changes in management practice will result in improvements in water quality. Quantifying denitrification is also important in estimating nutrient loading to groundwater through time. Measurements of dissolved nitrogen gas can detect and quantify saturated zone denitrification; and LLNL with GAMA funding has developed benchtop instrumentation to measure dissolved nitrogen in groundwater. This technique, membrane-inlet mass spectrometry (MIMS) requires the collection of an additional sample and is not routinely included in current GAMA water quality monitoring surveys. Incorporating dissolved nitrogen analysis into current water quality monitoring protocols without requiring an additional sample or separate analysis is the most cost-effective way to expand the database of dissolved nitrogen concentrations and document the prevalence of saturated-zone denitrification in California groundwater. The GAMA Priority Basin, Shallow Aquifer Assessment, and Special Study water quality monitoring programs routinely use dissolved noble gas and tritium analyses to constrain groundwater travel times and recharge. Noble gases are collected as a 10-mL water sample in a crimped copper tube and are analyzed by noble gas mass spectrometry (NGMS). Nitrogen, methane and carbon dioxide, can now also be measured in copper tubes and analyzed by the same LLNL NGMS system, which has been upgraded to allow such analyses. In the case of the GAMA Shallow Aquifer Assessment project, this will automatically provide dissolved nitrogen analyses at little or no incremental cost. A significant advantage of this technique is that archival copper tube noble gas samples can be analyzed using the technique. The dissolved nitrogen analyses – combined with nitrate analyses and the NGMS age information – will provide unique insight into nitrate sources, inputs, transport, and reaction rates.

54 ENVIRONMENTAL SCIENCES↗

In situ analysis of texture development from sinusoidal stress at high pressure and temperature

Here, we present a new experimental protocol to investigate the relationship between texture, plastic strain, and the mechanisms of plastic deformation at high pressure and temperature. The method utilizes synchrotron X-ray radiation as the probing tool, coupled with a large-volume high pressure deformation device (D-DIA). The intensity of X-ray diffraction peaks within the spectrum of the sample is used for sampling texture development in situ. The unique feature of this study is given by the sinusoidal variation of the intensity when a sinusoidal strain is applied to the sample. For a sample of magnesium oxide at elevated pressure and temperature, we demonstrate observations that are consistent with elasto-plastic models for texture development and for diffraction-peak measurements of apparent stress. The sinusoidal strain magnitude was 3%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigating the effects of proton exchange membrane fuel cell conditions on carbon supported platinum electrocatalyst composition and performance

Changes that carbon-supported platinum electrocatalysts undergo in a proton exchange membrane fuel cell environment were simulated by ex situ heat treatment of catalyst powder samples at 150 C and 100% relative humidity. In order to study modifications that are introduced to chemistry, morphology, and performance of electrocatalysts, XPS, HREELS and three-electrode rotating disk electrode experiments were performed. Before heat treatment, graphitic content varied by 20% among samples with different types of carbon supports, with distinct differences between bulk and surface compositions within each sample. Following the aging protocol, the bulk and surface chemistry of the samples were similar, with graphite content increasing or remaining constant and Pt-carbide decreasing for all samples. From the correlation of changes in chemical composition and losses in performance of the electrocatalysts, we conclude that relative distribution of Pt particles on graphitic and amorphous carbon is as important for electrocatalytic activity as the absolute amount of graphitic carbon present

08 HYDROGEN↗

Poly (lactide-co-glycolide) acid nanoencapsulation of a synthetic coumarin: Cytotoxicity and bio-distribution in mice, in cancer cell line and interaction with calf thymus DNA as target

Several naturally occurring coumarin compounds, including scopoletin (7 hydroxy-6 methoxycoumarin), of plant origin have been reported to have anti-cancer potentials. A related but chemically synthesized coumarin, 4-methyl-7-hydroxy coumarin (SC), was also shown to have similar anti-cancer potentials. In the present study, to test if nano-encapsulated SC could be a more potent anti-cancer agent, we encapsulated SC with poly lactide-co-glycolide acid (PLGA) nanoparticles (Nano Coumarin; NC) and tested its potentials with a variety of protocols. NC demonstrated greater efficiency of drug uptake and showed anti-cancer potentials in melanoma cell line A375, as revealed from scanning electronic and atomic force microscopies. To test its possible interaction with target DNA, the combined data of circular dichroism spectra (CD) and melting temperature profile (T{sub m}) of calf thymus DNA treated with NC were analyzed. Results indicated a concentration dependent interaction of NC with calf thymus DNA, bringing in effective change in structure and conformation, and forming a new complex that increased its stability. Particle size and morphology of NC determined through polydispersity index and zeta potential using dynamic light scattering qualified NC to be a more potent anti-cancer agent than SC. Further, SC and NC showed negligible cytotoxic effects on normal skin cells and peripheral blood mononuclear cells of mice. Distribution assay of PLGA nanoparticles in different tissues like brain, heart, kidneys, liver, lungs, and spleen in mice revealed the presence of nanoparticles in different tissues including brain, indicating that the particles could cross the blood brain barrier, significant information for drug design. - Graphical abstract: Nanoencapsulated coumarin (NC) were characterized for their size and morphology by scanning electron (SEM) and atomic force microscopies (AFM).The physical interaction of the NC with calf thymus DNA was studied through circular dichroism (CD) spectroscopies, using UV-visible titration and thermal denaturation studies. NC had a concentration dependent interaction with calf thymus DNA, could form a new complex with double helical DNA, increased the T{sub m} value and altered CD spectra of DNA and showed stronger anti-cancer effect than synthetic coumarin. Display Omitted Research Highlights: > Strategy for PLGA nano-encapsulation of a bioactive synthetic coumarin, 4 methyl 7 hydroxy coumarin (SC) is formulated. > Anti-cancer potentials of nano-encapsulated SC (NC) are evaluated in skin papilloma cells A375 through standard protocols. > Data of CD and Tm indicate concentration dependent interactions of NC bringing conformational changes in target DNA. > Particle size of NC and physico-chemical interactions with target DNA show NC as a more potent anti-cancer drug than SC. > NC has less cytotoxic effects, and can cross the blood brain barrier - important features for strategic drug design.

60 APPLIED LIFE SCIENCES↗

A semi-automatic method for left ventricle volume estimate: an in vivo validation study

This study aims to the validation of the left ventricular (LV) volume estimates obtained by processing volumetric data utilizing a segmentation model based on level set technique. The validation has been performed by comparing real-time volumetric echo data (RT3DE) and magnetic resonance (MRI) data. A validation protocol has been defined. The validation protocol was applied to twenty-four estimates (range 61-467 ml) obtained from normal and pathologic subjects, which underwent both RT3DE and MRI. A statistical analysis was performed on each estimate and on clinical parameters as stroke volume (SV) and ejection fraction (EF). Assuming MRI estimates (x) as a reference, an excellent correlation was found with volume measured by utilizing the segmentation procedure (y) (y=0.89x + 13.78, r=0.98). The mean error on SV was 8 ml and the mean error on EF was 2%. This study demonstrated that the segmentation technique is reliably applicable on human hearts in clinical practice.

NASA Discipline Cardiopulmonary↗

Potential of high-Z contrast agents in clinical contrast-enhanced computed tomography

Purpose: Currently, only iodine- and barium-based contrast media (CM) are used in clinical contrast-enhanced computed tomography (CE-CT). High-Z metals would produce a higher contrast at equal mass density for the x-ray spectra used in clinical CT. Using such materials might allow for significant dose reductions in CE-CT. The purpose of this study was to quantify the potential for dose reduction when using CM based on heavy metals. Methods: The contrast-to-noise ratio weighted by dose (CNRD) was determined as a function of scan protocol by means of measurements and simulations on a clinical CT scanner. For simulations, water cylinders with diameters 160, 320, 480, and 640 mm were used to cover a broad range of patient sizes. Measurements were conducted with 160 and 320 mm water-equivalent plastic cylinders. A central bore of 13 mm diameter was present in all phantoms. The tube voltage was varied from 80 to 140 kV for measurements and from 60 to 180 kV for simulations. Additional tin filtration of thicknesses 0.4, 0.8, and 1.2 mm was applied in the simulation to evaluate a range of spectral hardness. The bore was filled with a mixture of water and 10 mg/ml of pure iodine, holmium, gadolinium, ytterbium, osmium, tungsten, gold, and bismuth for the simulations and with aqueous solutions of ytterbium, tungsten, gold, and bismuth salts as well as Iopromid containing 10 mg/ml of the pure materials for the measurements. CNRDs were compared to iodine at phantom size-dependent reference voltages for all high-Z materials and the resulting dose reduction was calculated for equal contrast-to-noise ratio. Results: Dose reduction potentials strongly depended on phantom size, spectral hardness, and tube voltage. Depending on the added filtration, a dose reduction of 19%-60% could be reached at 80 kV with gadolinium for the 160 mm phantom, 52%-69% at 100 kV with holmium for the 320 mm phantom, 62%-78% with 120 kV for hafnium and the 480 mm phantom and 74%-86% with 140 kV for gold and the 640 mm phantom. While gadolinium might be considered at 160 mm diameter, hafnium showed the best overall performance for phantom sizes of 320 mm and above. The measurements conducted on the clinical CT scanner showed very good agreement with simulations with deviations in the order of 5 to 10%. Conclusions: The results of this study encourage the development and use of CM based on high-Z materials, especially for adipose patients, where high tube voltages are necessary to reach sufficiently short scan times. Hafnium proved to be the best compromise for average-size and for adipose patients. Even higher-Z materials such as gold and bismuth showed a good overall performance in conjunction with high tube voltage, large patients or strong added filtration and may be recommended for scans under these conditions.

61 RADIATION PROTECTION AND DOSIMETRY↗

Differential Motion Between Mediastinal Lymph Nodes and Primary Tumor in Radically Irradiated Lung Cancer Patients

Purpose/Objective: In patients with locally advanced lung cancer, planning target volume margins for mediastinal lymph nodes and tumor after a correction protocol based on bony anatomy registration typically range from 1 to 1.5 cm. Detailed information about lymph node motion variability and differential motion with the primary tumor, however, is lacking from large series. In this study, lymph node and tumor position variability were analyzed in detail and correlated to the main carina to evaluate possible margin reduction. Methods and Materials: Small gold fiducial markers (0.35 × 5 mm) were placed in the mediastinal lymph nodes of 51 patients with non-small cell lung cancer during routine diagnostic esophageal or bronchial endoscopic ultrasonography. Four-dimensional (4D) planning computed tomographic (CT) and daily 4D cone beam (CB) CT scans were acquired before and during radical radiation therapy (66 Gy in 24 fractions). Each CBCT was registered in 3-dimensions (bony anatomy) and 4D (tumor, marker, and carina) to the planning CT scan. Subsequently, systematic and random residual misalignments of the time-averaged lymph node and tumor position relative to the bony anatomy and carina were determined. Additionally, tumor and lymph node respiratory amplitude variability was quantified. Finally, required margins were quantified by use of a recipe for dual targets. Results: Relative to the bony anatomy, systematic and random errors ranged from 0.16 to 0.32 cm for the markers and from 0.15 to 0.33 cm for the tumor, but despite similar ranges there was limited correlation (0.17-0.71) owing to differential motion. A large variability in lymph node amplitude between patients was observed, with an average motion of 0.56 cm in the cranial-caudal direction. Margins could be reduced by 10% (left-right), 27% (cranial-caudal), and 10% (anteroposterior) for the lymph nodes and −2%, 15%, and 7% for the tumor if an online carina registration protocol replaced a protocol based on bony anatomy registration. Conclusions: Detailed analysis revealed considerable lymph node position variability, differential motion, and respiratory motion. Planning target volume margins can be reduced up to 27% in lung cancer patients when the carina registration replaces bony anatomy registration.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-148: Benchmarks and Pre-Treatment Reviews: A Study of Quality Assurance Effectiveness

Purpose: To determine the impact benchmarks and pre-treatment reviews have on improving the quality of submitted clinical trial data. Methods: Benchmarks are used to evaluate a site’s ability to develop a treatment that meets a specific protocol’s treatment guidelines prior to placing their first patient on the protocol. A pre-treatment review is an actual patient placed on the protocol in which the dosimetry and contour volumes are evaluated to be per protocol guidelines prior to allowing the beginning of the treatment. A key component of these QA mechanisms is that sites are provided timely feedback to educate them on how to plan per the protocol and prevent protocol deviations on patients accrued to a protocol. For both benchmarks and pre-treatment reviews a dose volume analysis (DVA) was performed using MIM softwareTM. For pre-treatment reviews a volume contour evaluation was also performed. Results: IROC Houston performed a QA effectiveness analysis of a protocol which required both benchmarks and pre-treatment reviews. In 70 percent of the patient cases submitted, the benchmark played an effective role in assuring that the pre-treatment review of the cases met protocol requirements. The 35 percent of sites failing the benchmark subsequently modified there planning technique to pass the benchmark before being allowed to submit a patient for pre-treatment review. However, in 30 percent of the submitted cases the pre-treatment review failed where the majority (71 percent) failed the DVA. 20 percent of sites submitting patients failed to correct their dose volume discrepancies indicated by the benchmark case. Conclusion: Benchmark cases and pre-treatment reviews can be an effective QA tool to educate sites on protocol guidelines and to minimize deviations. Without the benchmark cases it is possible that 65 percent of the cases undergoing a pre-treatment review would have failed to meet the protocols requirements.Support: U24-CA-180803.

60 APPLIED LIFE SCIENCES↗

The effect of tumor size and location on efficacy and safety of US- and CT- guided percutaneous microwave ablation in renal cell carcinomas

Purpose: To evaluate the effect of size and central location of the tumor on safety and efficacy of percutaneous CEUS- and CT-guided MWA in biopsy-proven renal cell carcinomas (RCCs). Materials and methods: In this IRB-approved retrospective study, 69 biopsy-proven renal tumors in 56 patients, who underwent MWA in our institution from January 2013 to March 2017, were evaluated. Data collection included demographics, tumor characteristics, procedural protocols, and follow-up visits within 6 months post procedure. Primary outcomes were assessed by technical success (TS), local tumor progression (LTP), and complications. The Kaplan–Meier analysis was used for survival rate. Results: Overall technical success was achieved for all 69 lesions (92.8% primary TS, 100% overall). Median nephrometry score was 8 (4–11) and median tumor size was 2.5 cm (0.8–7). Five lesions which required second ablation had significantly higher median tumor size 4 cm (P = 0.039) with the same nephrometry score. Renal function remained stable with no significant change in eGFR before or after ablation. The LTP rate was 5.8%. The most recurrent tumors were clear cell (50%) followed by papillary tumors (25%). The complication rate was 5.8% with minor complications (hematoma and pain) and no major issues. There was no significant association between nephrometry score and technical success, recurrence, or complication rates. Overall and tumor-specific survival rates were 96.7% and 100% at 11.9 months. Conclusions: Image-guided MWA appears to be a safe and effective treatment regardless of nephrometry score and tumor location with high technical success, low recurrence, and complication rates.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Perfusion Angiography of the Foot in Patients with Critical Limb Ischemia: Description of the Technique

ObjectiveTo study the feasibility of 2D perfusion imaging in critical limb ischemia (CLI).Methods/ResultsPerfusion angiography is a new technology which was tested in 18 patients with CLI of the foot. A standardized protocol was used with a catheter placed at the mid-part of the popliteal artery, and a total of 9 cc of non-ionic iodinated contrast material was injected at a rate of 3 cc/sec. The technology is based on early cardiology research where iodinated contrast agents were used for imaging of cardiac perfusion. During the first pass of the contrast, there is a significant diffusion of the contrast agents into the interstitial space, particularly for non-ionic and low-molecular-weight compounds.DiscussionThe original angiography data can be used to make a time–density curve, which represents the actual perfusion of the foot in time. Angiographic perfusion imaging is a post-processing modality for which no extra contrast or radiation is needed. With this technique, it is possible to get more information about the perfusion status and microcirculation of the foot. This is a step toward functional imaging in CLI patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗