Search NASA⌕ Search

SEARCH · Search NASA

Results for “Acceleration methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Spatiotemporal Structure in Intense THz Pulsed Beams

Optically generated terahertz radiation, with gigavolt per meter (GV/m) electric fields accessible in tabletop experiments, provides a promising source of accelerating gradients for future particle accelerator applications. Manipulation and characterization of radiation is essential for efficiently producing high fields and effectively delivering them to an accelerating structure or interaction region. The talk will cover a method of generating and characterizing high quality and structured terahertz pulsed laser beams for compact particle acceleration.

Hine, George↗

UV-Fluorescence Imaging of Silicon PV Modules After Outdoor Aging and Accelerated Stress Testing

Fast, non-destructive, outdoor-compatible methods for photovoltaic module characterization are essential for monitoring module quality without disrupting energy production. UV-fluorescence (UVF) imaging of the encapsulant layer can be used for crack detection in the field. We show that UVF patterns vary widely between modules and types of applied stress. We propose that combining accelerated stress testing (e.g. thermal cycling and damp heat) with field investigations can help build understanding of different types of UVF, which are formed and subsequently quenched at varying rates. Ultimately, such understanding could enable estimating when cracks were formed.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Numerical simulation of the dynamics of a liquid crystal in the case of plane strain using GPUs

Parallel computational algorithm is worked out for numerical implementation of two-dimensional dynamic model of a liquid crystal, which takes into account the mutual influence of three physical effects – transfer of acoustic energy due to translational motion, viscoelastic rotation of the particles under the action of tangential stresses, anisotropic thermal expansion and compression. The algorithm is based on the Godunov gap decay method, the Ivanov scheme with controlled dissipation of energy and the splitting method with respect to spatial variables. The CUDA technology for computer systems with graphic accelerators is used. Results of computations demonstrating the efficiency of proposed method and algorithm are represented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Poster — Thur Eve — 46: Monte Carlo model of the Novalis Classic 6MV stereotactic linear accelerator using the GATE simulation platform

Monte Carlo (MC) simulation is accepted as the most accurate method to predict dose deposition when compared to other methods in radiation treatment planning. Current dose calculation algorithms used for treatment planning can become inaccurate when small radiation fields and tissue inhomogeneities are present. At our centre the Novalis Classic linear accelerator (linac) is used for Stereotactic Radiosurgery (SRS). The first MC model to date of the Novalis Classic linac was developed at our centre using the Geant4 Application for Tomographic Emission (GATE) simulation platform. GATE is relatively new, open source MC software built from CERN's Geometry and Tracking 4 (Geant4) toolkit. The linac geometry was modeled using manufacturer specifications, as well as in-house measurements of the micro MLC's. Among multiple model parameters, the initial electron beam was adjusted so that calculated depth dose curves agreed with measured values. Simulations were run on the European Grid Infrastructure through GateLab. Simulation time is approximately 8 hours on GateLab for a complete head model simulation to acquire a phase space file. Current results have a majority of points within 3% of the measured dose values for square field sizes ranging from 6×6 mm{sup 2} to 98×98 mm{sup 2} (maximum field size on the Novalis Classic linac) at 100 cm SSD. The x-ray spectrum was determined from the MC data as well. The model provides an investigation into GATE'S capabilities and has the potential to be used as a research tool and an independent dose calculation engine for clinical treatment plans.

60 APPLIED LIFE SCIENCES↗

Hawking radiation of scalar particles from accelerating and rotating black holes

Hawking radiation of uncharged and charged scalar particles from accelerating and rotating black holes is studied. We calculate the tunneling probabilities of these particles from the rotation and acceleration horizons of these black holes. Using this method we recover the correct Hawking temperature as well.

79 ASTRONOMY AND ASTROPHYSICS↗

Towards improved CZT crystals.

Past experimental efforts to improve CZT crystals for gamma spectrometer applications have been focused on reducing micron-scale defects such as tellurium inclusions and precipitates. While these micron-scale defects are important, experiments have shown that the micron-scale variations in transport can be caused by the formation and aggregation of atomic-scale defects such as dislocations and point defect clusters. Moreover, dislocation cells have been found to act as nucleation sites that cause the formation of large precipitates. To better solve the uniformity problem of CZT, atomic-scale defects must be understood and controlled. To this end, we have begun to develop an atomistic model that can be used to reveal the effects of small-scale defects and to guide experiments for reducing both atomic- and micron-scale (tellurium inclusions and precipitates) defects. Our model will be based upon a bond order potential (BOP) to enable large-scale molecular dynamics simulations of material structures at a high-fidelity level that was not possible with alternative methods. To establish how BOP improves over existing approaches, we report here our recent work on the assessment of two representative literature CdTe interatomic potentials that are currently widely used: the Stillinger-Weber (SW) potential and the Tersoff-Rockett (TR) potential. Careful examinations of phases, defects, and surfaces of the CdTe system were performed. We began our study by using both potentials to evaluate the lattice constants and cohesive energies of various Cd, Te, and CdTe phases including dimer, trimer, chain, square, rhomboid, tetrahedron, diamond-cubic (dc), simple-cubic (sc), body-centered-cubic (bcc), face-centered cubic (fcc), hexagonal-close-packed (hcp), graphite-sheet, A8, zinc-blende (zb), wurtzite (wz), NaCl, CsCl, etc. We then compared the results with our calculations using the density functional theory (DFT) quantum mechanical method. We also evaluated the suitability of the two potentials to predict the surface reconstructions and surface energies, various defect configurations and defect energies (interstitials and voids), elastic constants, and melting temperatures of different phases. We found that both potentials predicted incorrect energy trends as compared with those predicted by the DFT method. Most seriously, both potentials predicted incorrect lowest energy phases. These studies clearly showed that the existing potentials are not sufficient for correctly predicting the charge transport properties of CdTe demonstrating the need for a new potential. We anticipate that our BOP method will overcome this problem and will accelerate the discovery of a synthesis approach to produce improved CZT crystals.

36 MATERIALS SCIENCE↗

Electrostatics of proteins in dielectric solvent continua. II. Hamiltonian reaction field dynamics

In Paper I of this work [S. Bauer, G. Mathias, and P. Tavan, J. Chem. Phys. 140, 104102 (2014)] we have presented a reaction field (RF) method, which accurately solves the Poisson equation for proteins embedded in dielectric solvent continua at a computational effort comparable to that of polarizable molecular mechanics (MM) force fields. Building upon these results, here we suggest a method for linearly scaling Hamiltonian RF/MM molecular dynamics (MD) simulations, which we call “Hamiltonian dielectric solvent” (HADES). First, we derive analytical expressions for the RF forces acting on the solute atoms. These forces properly account for all those conditions, which have to be self-consistently fulfilled by RF quantities introduced in Paper I. Next we provide details on the implementation, i.e., we show how our RF approach is combined with a fast multipole method and how the self-consistency iterations are accelerated by the use of the so-called direct inversion in the iterative subspace. Finally we demonstrate that the method and its implementation enable Hamiltonian, i.e., energy and momentum conserving HADES-MD, and compare in a sample application on Ac-Ala-NHMe the HADES-MD free energy landscape at 300 K with that obtained in Paper I by scanning of configurations and with one obtained from an explicit solvent simulation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Geometric Analysis Based Double Closed-loop Iterative Learning Control of Output PDF Shaping of Fiber Length Distribution in Refining Process

In order to improve the pulp quality and to reduce the energy consumption, the fiber length distribution (FLD) is generally employed as one of the important technological indexes in the refining process. Considering that the traditional mean and variance of fiber length are unable to adequately characterize the non-Gaussian distribution properties, this paper proposes a novel geometric analysis based double closed-loop iterative learning control (ILC) method for probability density function (PDF) shaping of output FLD in the refining process. Primarily, a RBF neural network (NN) with Gaussian-type is utilized to approximate the square root PDF in the inner loop, where the RBF basis function parameters (center and width) are tuned between any two adjacent batches by using an ILC law, and the subspace identification method can be applied to establish the state-space model of weight vector. Then, for the sake of accelerating the convergence rate of the closed-loop sysyem, a geometric analysis based ILC method is adopted in the outer loop. Lastly, both simulation and experiments demonstrate the effectiveness and practicability of the proposed approach.

42 ENGINEERING↗

Computation of Ion Charge State Distributions After Inner-Shell Ionization In Ne, Ar And Kr Atoms Using Monte Carlo Simulation

Atomic reorganization starts by filling the initially inner-shell vacancy by a radiative transition (x-ray) or by a non-radiative transition (Auger and Coster-Kronig processes). New vacancies created during this atomic reorganization may in turn be filled by further radiative and non-radiative transitions until all vacancies reach the outermost occupied shells. The production of inner-shell vacancy in an atom and the de-excitation decays through radiative and non-radiative transitions may result in a change of the atomic potential; this change leads to the emission of an additional electron in the continuum (electron shake-off processes). In the present work, the ion charge state distributions (CSD) and mean atomic charge ions produced from inner-shell vacancy de-excitation decay are calculated for neutral Ne, Ar and Kr atoms. The calculations are carried out using Monte Carlo (MC) technique to simulate the cascade development after primary vacancy production. The radiative and non-radiative transitions for each vacancy are calculated in the simulation. In addition, the change of transition energies and transition rates due to multi vacancies produced in the atomic configurations through the cascade development are considered in the present work. It is found that considering the electron shake--off process and closing of non-allowed non-radiative channels improves the results of both charge state distributions (CSD) and average charge state. To check the validity of the present calculations, the results obtained are compared with available theoretical and experimental data. The present results are found to agree well with the available theoretical and experimental values.

36 MATERIALS SCIENCE↗

NIOLD Run 4 Report

In this report we discuss the motivation, methods, and analysis of the IOTA Run 4 studies of the Nonlinear Integrable Optics, Landau Damping (NIOLD) experiment. We introduce Landau Damping, an effect that damps collective instabilities in particle accelerators. We also introduce and discuss a new method to measure stability diagrams which quantify the strength of Landau Damping, that employs an antidamper. We also present the data collection process, the data analysis procedure, and the preliminary results. The first results qualitatively agree with the analytical predictions and the simulations. Next steps for the current data and goals for future data are also discussed.

43 PARTICLE ACCELERATORS↗

Comparison of methods for the measurement of radiation dose distributions in high dose rate (HDR) brachytherapy: Ge-doped optical fiber, EBT3 Gafchromic film, and PRESAGE{sup Registered-Sign} radiochromic plastic

Purpose: Dose distribution measurement in clinical high dose rate (HDR) brachytherapy is challenging, because of the high dose gradients, large dose variations, and small scale, but it is essential to verify accurate treatment planning and treatment equipment performance. The authors compare and evaluate three dosimetry systems for potential use in brachytherapy dose distribution measurement: Ge-doped optical fibers, EBT3 Gafchromic film with multichannel analysis, and the radiochromic material PRESAGE{sup Registered-Sign} with optical-CT readout. Methods: Ge-doped SiO{sub 2} fibers with 6 {mu}m active core and 5.0 mm length were sensitivity-batched and their thermoluminescent properties used via conventional heating and annealing cycles. EBT3 Gafchromic film of 30 {mu}m active thickness was calibrated in three color channels using a nominal 6 MV linear accelerator. A 48-bit transmission scanner and advanced multichannel analysis method were utilized to derive dose measurements. Samples of the solid radiochromic polymer PRESAGE{sup Registered-Sign }, 60 mm diameter and 100 mm height, were analyzed with a parallel beam optical CT scanner. Each dosimetry system was used to measure the dose as a function of radial distance from a Co-60 HDR source, with results compared to Monte Carlo TG-43 model data. Each system was then used to measure the dose distribution along one or more lines through typical clinical dose distributions for cervix brachytherapy, with results compared to treatment planning system (TPS) calculations. Purpose-designed test objects constructed of Solid Water and held within a full-scatter water tank were utilized. Results: All three dosimetry systems reproduced the general shape of the isolated source radial dose function and the TPS dose distribution. However, the dynamic range of EBT3 exceeded those of doped optical fibers and PRESAGE{sup Registered-Sign }, and the latter two suffered from unacceptable noise and artifact. For the experimental conditions used in this study, the useful range from an isolated HDR source was 5-40 mm for fibers, 3-50 mm for EBT3, and 4-21 mm for PRESAGE{sup Registered-Sign }. Fibers demonstrated some over-response at very low dose levels, suffered from volume averaging effects in the dose distribution measurement, and exhibited up to 9% repeatability variation over three repeated measurements. EBT3 demonstrated excellent agreement with Monte Carlo and TPS dose distributions, with up to 3% repeatability over three measurements. PRESAGE{sup Registered-Sign} gave promising results, being the only true 3D dosimeter, but artifacts and noise were apparent. Conclusions: The comparative response of three emerging dosimetry systems for clinical brachytherapy dose distribution measurement has been investigated. Ge-doped optical fibers have excellent spatial resolution for single-direction measurement but are currently too large for complex dose distribution assessment. The use of PRESAGE{sup Registered-Sign} with optical-CT readout gave promising results in the measurement of true 3D dose distributions but further development work is required to reduce noise and improve dynamic range for brachytherapy dose distribution measurements. EBT3 Gafchromic film with multichannel analysis demonstrated accurate and reproducible measurement of dose distributions in HDR brachytherapy. Calibrated dose measurements were possible with agreement within 1.5% of TPS dose calculations. The suitability of EBT3 as a dosimeter for 2D quality control or commissioning work has been demonstrated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

4D beam matrix reconstruction in particle accelerators

Transverse beam parameters in particle accelerators are commonly described using the Twiss parameters, which are experimentally accessible yet inherently limited because they neglect correlations between different transverse coordinates. Such correlations frequently arise from uncompensated cathode magnetic fields or misaligned focusing quadrupoles, affecting beam quality and accelerator performance. To address this limitation, we propose and validate a novel diagnostic method for the complete four-dimensional (4D) transverse beam matrix. Our method involves passing the beam through a beamline comprising both conventional and skew quadrupole magnets, followed by downstream measurements of the resulting two-dimensional (2D) beam profiles. These measurements represent distinct 2D projections of the underlying 4D transverse phase–space distribution. By systematically varying quadrupole strengths, multiple independent projections of the beam phase space are obtained. We reconstruct the original 4D beam matrix from these measured projections using an optimization-based least-square fit, providing fast and robust reconstruction regardless of the specific beamline configuration. Through extensive numerical simulations and realistic particle-tracking studies, we demonstrate the diagnostic’s accuracy, robustness, and capability to achieve reconstruction uncertainties smaller than measurement errors, particularly when employing sufficient numbers of quadrupole scans. This method presents a powerful and flexible approach for comprehensive beam characterization and accelerator tuning.

43 PARTICLE ACCELERATORS↗

TH-CD-BRA-02: 3D Remote Dosimetry for MRI-Guided Radiation Therapy: A Hybrid Approach

Purpose: To validate the dosimetric accuracy of a commercially available MR-IGRT system using a combination of 3D dosimetry measurements (with PRESAGE(R) radiochromic plastic and optical-CT readout) and an in-house developed GPU-accelerated PENELOPE Monte-Carlo dose calculation system. Methods: {sup 60}Co IMRT subject to a 0.35T lateral magnetic field has recently been commissioned in our institution following AAPM’s TG-119 recommendations. We performed PRESAGE(R) sensitivity studies in 4ml cuvettes to verify linearity, MR-compatibility, and energy-independence. Using 10cm diameter PRESAGE(R), we delivered an open calibration field to examine the percent depth dose and a symmetrical 3-field plan with three adjacent regions of varying dose to determine uniformity within the dosimeter under a magnetic field. After initial testing, TG-119 plans were created in the TPS and then delivered to 14.5cm 2kg PRESAGE(R) dosimeters. Dose readout was performed via optical-CT at a second institution specializing in remote 3D dosimetry. Absolute dose was measured using an IBA CC01 ion chamber and the institution standard patient-specific QA methods were used to validate plan delivery. Calculated TG-119 plans were then compared with an independent Monte Carlo dose calculation (gPENELOPE). Results: PRESAGE(R) responds linearly (R{sup 2}=0.9996) to {sup 60}Co irradiation, in the presence of a 0.35T magnetic field, with a sensitivity of 0.0305(±0.003)cm{sup −1}Gy{sup −1}, within 1% of a 6MV non-MR linac irradiation (R{sup 2}=0.9991) with a sensitivity of 0.0302(±0.003)cm{sup −1}Gy{sup −1}. Analysis of TG-119 clinical plans using 3D-gamma (3%/3mm, 10% threshold) give passing rates of: HN 99.1%, prostate 98.0%, C-shape 90.8%, and multi-target 98.5%. The TPS agreed with gPENELOPE with a mean gamma passing rate of 98.4±1.5% (2%/2mm) with the z-score distributions following a standard normal distribution. Conclusion: We demonstrate for the first time that 3D remote dosimetry using both experimental and computational methods is a feasible and reliable approach to commissioning MR-IMRT, which is particularly useful for less specialized clinics in adopting this new treatment modality.

60 APPLIED LIFE SCIENCES↗

Machine Learning for Automated Extraction of Building Geometry

As data science comes to buildings, the promise of using machine learning and novel sources of data has received much attention. Advances in machine learning and computer vision algorithms, combined with increased access to unstructured data (e.g., images and text), have created an opportunity for automated extraction of building characteristics – cost-effectively, and at scale. Acquisition of features such as footprint are time consuming and costly to acquire with today’s manual methods, but can be streamlined through intelligent software-based solutions applied to satellite images. When combined with aerial RGB and thermal images, full 3D geometries and thermal maps can be constructed to determine additional characteristics such as window to wall ratio, height, number of stories and envelope thermal characteristics. In this paper we present three contributions to accelerate these high potential opportunities: (1) a methodical analysis of how these features can be integrated into today’s simulation and data driven software tools to enhance efficiency measure identification and owner/operator decision making; (2) development and accuracy testing of open source deep neural network methods to extract building footprints from satellite imagery, including the curation and application of openly available GIS datasets for training and continued development by others; and (3) an open framework for drone-based image capture and creation of 3D building geometries. This work represents an important bridge between high-level studies that span diverse application areas and those that detail point solutions yet cannot be easily replicated or extended.

Touzani, Samir↗

Multiscale Characterization of Photovoltaic Modules—Case Studies of Contact and Interconnect Degradation

The current popularity of photovoltaic (PV) systems is due in large part to their exceptional reliability and significantly lower cost than other energy sources. Studying cell and module degradation is key to promote further development in the state of the art. Fielded or accelerated aged modules exhibit different failure modes, of which metallization degradation (contacts and interconnections) is prevalent. In this work, we discuss how multiscale characterization methods can be applied to a variety of module technologies that have been field exposed and have undergone accelerated age testing. These methods include performing characterization on the module level, cell level, and finally the materials level. The observed performance losses from the module- and cell-level characterization can be correlated with materials properties to find out the root cause of degradation. We recommend an initial nondestructive characterization suite, including module- and cell-level current-voltage ( I--V ), Suns-V OC , photoluminescence and electroluminescence imaging, quantum efficiency, ultraviolet fluorescence imaging, and thermal infrared imaging. Samples are then extracted from particularly degraded regions of the module and prepared for materials characterization techniques, such as top-down and cross-sectional scanning electron microscopy, energy-dispersive X-ray spectroscopy, X-ray photoelectron spectroscopy, secondary ion mass spectrometry, Raman spectroscopy, and transmission electron microscopy, allowing a deeper look into the mechanism behind the metallization degradation. This article serves as an instructional review to introduce the different multiscale characterization methods and how they can be effectively applied to perform PV degradation studies. Furthermore, we also share some of our examples and discuss the strengths, limitations, and best practices for each of the characterization techniques.

14 SOLAR ENERGY↗

Computationally Guided Design of Multiple Impurities Tolerant Cathode for Solid Oxide Fuel Cell Applications

Solid oxide fuel cells (SOFCs) have been recognized as promising candidates in the demand of reducing the dependence on fossil fuels, which is one of the solutions to the threat of global warming. It was reported that the direct chemical-to-electrical energy conversion in SOFCs comes with negligible emission of greenhouse gases and up to 60% working efficiency. SOFC has unique advantages over traditional power generation technologies and other types of fuel cells due to the use of relatively inexpensive materials, low sensitivity to poisoning impurities in fuels, relatively high conversion efficiency, and fuel flexibility (like carbon-based fuels). However, during the SOFC operation, the cathode is exposed to intrinsic and extrinsic airborne contaminants at high temperatures (600–900°C), leading to their reaction with electrode materials, irreversible chemical and structural changes, and electrochemical performance degradation. of which CO2, SO2, Cr6+ and H2O are known to be concerns. Thus, developing a comprehensive understanding of the multiple impurities poisoning of SOFC cathodes in the presence of single or multiple impurities is necessary to address the long-term degradation of the SOFC cathode systems at operating conditions. An integrated computational and experimental approach has been utilized in the current work aiming at the comprehensive investigation of the cathode materials under single or multiple impurities poisoning effects, understanding the multiple impurities poisoning mechanism(s), and improving the long-term durability of the SOFC cathodes to develop better performing impurity-tolerant cathode materials. We first examined the agreement between the simulation approach and the experimental observations at various atmospheric and temperature conditions to confirm the reliability of CALPHAD for poisoning simulations in these cathodes. Then, using this approach, we investigated the accelerated testing protocol, which has become the standard method for conducting impurity poisoning experiments involving these cathode materials. We found our simulation approach is able to predict in which systems, i.e., cathode material and treatment environment, the accelerated testing protocols reflect actual operating conditions. Finally, in-depth simulations were done for these three candidate cathodes under different experimental conditions and suggested directions toward alternative cathode materials that have superior impurity tolerance.

36 MATERIALS SCIENCE↗

Learning Only on Boundaries: A Physics-Informed Neural Operator for Solving Parametric Partial Differential Equations in Complex Geometries

Recently, deep learning surrogates and neural operators have shown promise in solving partial differential equations (PDEs). However, they often require a large amount of training data and are limited to bounded domains. In this work, we present a novel physics-informed neural operator method to solve parameterized boundary value problems without labeled data. By reformulating the PDEs into boundary integral equations (BIEs), we can train the operator network solely on the boundary of the domain. This approach reduces the number of required sample points from $O(N^d)$ to $O(N^{d-1}$), where $d$ is the domain’s dimension, leading to a significant acceleration of the training process. Additionally, our method can handle unbounded problems, which are unattainable for existing physics-informed neural networks (PINNs) and neural operators. Finally, our numerical experiments show the effectiveness of parameterized complex geometries and unbounded problems.

97 MATHEMATICS AND COMPUTING↗

Parametric Optimization of Undulators for NSLS-II Project Beamlines

General optimization procedure, computation methods used, and the obtained optimal parameters of undulators for the NSLS-II project beamlines are reported. The optimization starts with high-accuracy calculation of undulator magnetic fields, using Radia magnetostatics code, for a large set of periods and vertical gaps of a given undulator type, given magnetic materials and a scalable magnet geometry. From the resulting magnetic fields, a sub-set of undulator periods and the corresponding vertical gaps, providing the required low-energy cut-off values of spectral harmonics for each particular beamline, is determined. In parallel, from the same Radia undulator models, angular magnetic kick maps are calculated, and the insertion device effect on electron beam is simulated using Tracy-2 tracking code based on symplectic integrator. After these simulations, magnet parameters are fine-tuned and the maximal acceptable undulator lengths are determined for different straight sections, as functions of minimal gap and with due regard for the electron beam vertical ''stay clear'' constraint in the case of in-vacuum undulators. Finally, the optimal undulator period and length are determined as the values providing maximal spectral flux among the pre-selected undulator cases, already satisfying the requirements concerning the harmonic cut-off values and the effect on electron beam.

43 PARTICLE ACCELERATORS↗