Search NASA⌕ Search

SEARCH · Search NASA

Results for “diffraction contrast”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Investigating the Relationship Between Bolide Entry Angle and Apparent Direction of Infrasound Signal Arrivals

Infrasound sensing offers critical capabilities for detecting and geolocating bolide events globally. However, the observed back azimuths, directions from which infrasound signals arrive at stations, often differ from the theoretical expectations based on the bolide’s peak brightness location. For objects with shallow entry angles, which traverse longer atmospheric paths, acoustic energy may be emitted from multiple points along the trajectory, leading to substantial variability in back azimuth residuals. This study investigates how the entry angle of energetic bolides affects the back azimuth deviations, independent of extrinsic factors such as atmospheric propagation, station noise, and signal processing methodologies. A theoretical framework, the Bolide Infrasound Back-Azimuth EXplorer Model (BIBEX-M), was developed to compute predicted back azimuths solely from geometric considerations. The model quantifies how these residuals vary as a function of source-to-receiver distance, revealing that bolides entering at shallow angles, e.g., 10°, can produce average residuals of 20°, with deviations reaching up to 46° at distances below 1000 km, and remaining significant even at 5000 km (up to 8°). In contrast, bolides with steeper entry angles, e.g., > 60°, show smaller deviations, typically under 5° at 1000 km and diminishing to less than ~1° beyond 5000 km. These findings attest to the need for careful interpretation when evaluating signal detections and estimating bolide locations. This work is not only pertinent to bolides but also to other high-energy, extended-duration atmospheric phenomena such as space debris and reentry events, where similar geometric considerations can influence infrasound arrival directions.

Acoustics↗

X-ray scatter correction method for dedicated breast computed tomography

Purpose: To improve image quality and accuracy in dedicated breast computed tomography (BCT) by removing the x-ray scatter signal included in the BCT projections. Methods: The previously characterized magnitude and distribution of x-ray scatter in BCT results in both cupping artifacts and reduction of contrast and accuracy in the reconstructions. In this study, an image processing method is proposed that estimates and subtracts the low-frequency x-ray scatter signal included in each BCT projection postacquisition and prereconstruction. The estimation of this signal is performed using simple additional hardware, one additional BCT projection acquisition with negligible radiation dose, and simple image processing software algorithms. The high frequency quantum noise due to the scatter signal is reduced using a noise filter postreconstruction. The dosimetric consequences and validity of the assumptions of this algorithm were determined using Monte Carlo simulations. The feasibility of this method was determined by imaging a breast phantom on a BCT clinical prototype and comparing the corrected reconstructions to the unprocessed reconstructions and to reconstructions obtained from fan-beam acquisitions as a reference standard. One-dimensional profiles of the reconstructions and objective image quality metrics were used to determine the impact of the algorithm. Results: The proposed additional acquisition results in negligible additional radiation dose to the imaged breast ({approx}0.4% of the standard BCT acquisition). The processed phantom reconstruction showed substantially reduced cupping artifacts, increased contrast between adipose and glandular tissue equivalents, higher voxel value accuracy, and no discernible blurring of high frequency features. Conclusions: The proposed scatter correction method for dedicated breast CT is feasible and can result in highly improved image quality. Further optimization and testing, especially with patient images, is necessary to characterize its impact on clinical performance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Phase Evolution in Ba-(Nd,Eu,Gd)-Cu-O-Coated Conductor Films

Phases that are in equilibrium with BaR{sub 2}CuO{sub 6+}x (R = lanthanides and Y), such as the 'green-phase' and 'brown-phase' structural variants of BaR{sub 2}CuO{sub 5} in bulk samples, are attractive choices for flux-pinning for coated conductor applications because of the guaranteed chemical stability. In films, high-temperature x-ray diffraction studies of Ba{sub 2}RCu{sub 3}O{sub 6+}x superconductor deposited on SrTiO{sub 3} substrate using the trifluoroacetate solution method demonstrate that while BaNd{sub 2}CuO{sub 5} ('brown-phase' structure) develops at 735 C and 100 Pa{sub p{sub O2}}, neither BaGd{sub 2}CuO{sub 5} nor Ba(Nd{sub 1/3}Eu{sub 1/3}Gd{sub 1/3}){sub 2}CuO{sub 5} (both green-phase structure) form at these conditions. As a result, Ba{sub 2}(Nd{sub 1/3}Eu{sub 1/3}Gd{sub 1/3})Cu{sub 3}O{sub 6+}x in thin films is in equilibrium with the brown-phase, and Ba{sub 2}GdCu{sub 3}O{sub 6+}x is in equilibrium with Gd{sub 2}O{sub 3} in the Ba-Gd-Cu-O system, in contrast to the bulk systems. Different phase relationships in the vicinity of the Ba{sub 2}RCu{sub 3}O{sub 6+}x phase imply different phases are available for flux-pinning applications. These differences will need to be considered carefully in designing optimized superconducting coated conductors.

36 MATERIALS SCIENCE↗

A Combined Study Investigating the Insoluble and Soluble Organic Compounds in Category 3 Carbonaceous Itokawa Particles Recovered by the Hayabusa Mission

At the 3rd International Announcement of Opportunity (AO), we have been approved for five Category 3 carbonaceous Itokawa particles (RA-QD02-0012, RA-QD02-0078, RB-CV-0029, RB-CV-0080 and RB-QD04-0052) recovered by the first Hayabusa mission of JAXA. In this investigation, we aim to provide a comprehensive study to characterize and account for the presence of carbon-bearing phases as suggested by the initial Scanning Electron Microscopy (SEM) analysis carried out by JAXA at the curation facility, and to describe the mineralogical components of the particles. The insoluble organic content of Itokawa particle has been investigated with the use of micro-Raman spectroscopy by Kitajima and co-workers [1]. The Raman spectra of Itokawa particles show broad G- and D-bands typical of low temperature material which offers an interesting contrast to the high metamorphic grade (LL4-6) of the Itokawa parent body. Amino acid analysis has been conducted by Naraoka et al. [2] to study the soluble organic component of Itokawa particles, but since it was a preliminary study and thus did not have the opportunity to target on Category 3 carbonaceous particles, only terrestrial contaminants were identified. The investigation will be carried out in the following order prioritized according to the progressive damage the analytical techniques can induce: (1) micro-Raman spectrometry, (2) two-step laser mass spectrometry (micro-L2MS), (3) ultra-high performance liquid chromatography with fluorescence detection and time-of-flight mass spectrometry (LC-FD/ToF-MS), and optimally if we can recover the particles after wet chemistry analysis, we will mount the samples and perform (4) electron beam microscopy (SEM, electron back-scattered diffraction [EBSD]) and (5) carbon X-ray absorption near edge structure spectroscopy (C-XANES). We will begin the analytical procedures upon receiving the samples in September/October. This work will provide us with an understanding of the variety and origins of the carbon-bearing phases present in primitive solar system bodies from a direct sample-returned mission, which is less likely hampered by risks of terrestrial contamination as compared to meteorite finds and falls.

Chan, Q. H. S.↗

Multimodal study of the impact of stimulation pH on shale pore structure, with an emphasis on organics behavior in alkaline environments

The tight nature of shale formations calls for hydraulic fracturing techniques able of altering the pore architecture to facilitate the production of hydrocarbon resources. The composition, pH, salinity, density and chemistry of Hydraulic Fracturing Fluids (HFF) vary substantially depending on reservoir characteristics. pH is among the most important stimulation fluid properties, ranging from very acidic, for carbonate reservoirs, to basic, in the case of clay-rich formations. pH regulates what geochemical reactions take place between the stimulation fluid and shale, as well as pore architecture alteration. The dissolution of carbonates and pyrite, and the precipitation of common minerals such as barite, gypsum and iron oxides in acidic environments have been extensively documented. In contrast, alkali stimulation environments and the role of organic components have received less attention. This research provides insight into the role of both minerals and organic components during alkaline stimulation, and the resulting pore architecture alterations. Here, a set of reactive experiments are performed using three different shales, with varying organic matter (OM) content, at different pH (3, 6, 8, 10, 12). The analysis of pore architecture alteration induced by the reaction was performed via nitrogen (N2) gas adsorption and Time-Domain Nuclear Magnetic Resonance (TD-NMR). Inductively Coupled Plasma - Optical Emission Spectrometry (ICP-OES) was used to measure the composition of the stimulation fluid post-reaction. The system with a larger impact on the pore architecture (pH 12) underwent a more extensive analysis through the application of Focused Ion Beam Scanning Electron Microscopy (FIB-SEM) and x-ray Diffraction (XRD). Results show that mineral dissolution contributed to the creation of secondary porosity, mainly through dissolution of clays and silicates. We show that the abundance and distribution of organic matter both play a significant role in changes in pore architecture. Most samples showed an increase in inter-organic porosity, likely due to the organic acids within kerogen reacting with the stimulation fluid. Samples with a larger amount and more widespread distribution of organic matter show the most significant alterations. Finally, we also highlight the dissolution process of iron-rich minerals, including framboidal pyrite, as another important source of secondary porosity.

04 OIL SHALES AND TAR SANDS↗

Crystal Growth through Progressive Densification Identified by Synchrotron Small-Angle X-ray Scattering

For the first time, evolution of the interfacial structure of aluminum hydroxide nuclei forming within concentrated caustic solutions has been examined in situ in real time. In both dilute and concentrated caustic aluminate solutions (NaOH = 1.0 and 3.0 M, respectively, [NaOH]/[Al] = 1.22), the measured synchrotron small-angle X-ray scattering data indicate distinctly different surface structures throughout the maturation process. In the dilute solution, the data are consistent with a thin layer of less dense, recently accreted material on the surface of large fully dense particles -- consistent with the familiar model process of species attachment to well-faceted surfaces. In contrast to this, the data for the concentrated solution are consistent with large diffuse particles growing with a mass fractal dimension of approximately 2.5 which densify to form rough surface fractal particles on maturation. This unusual densification crystallization mechanism may occur in analogous concentrated systems where the fractal structures may be entropically stablized.

43 PARTICLE ACCELERATORS↗

First refraction contrast imaging via Laser-Compton Scattering X-ray at KEK

Laser-Compton Scattering (LCS) is one of the most feasible techniques for high quality, high brightness, and compact X-ray source. High energy electron beam produced by accelerators scatters off the laser photon at a small spot. As a laser target, we have been developing a pulsedlaser storage cavity for increasing an X-ray flux. The X-ray flux was still inadequate that was 2.1 Multiplication-Sign 10{sup 5}/sec, however, we performed first refraction contrast imaging in order to evaluate the quality of LCS X-ray. Edge enhanced contrast imaging was achieved by changing the distance from sample to detector. The edge enhancement indicates that the LCS X-ray has small source size, i.e. high brightness. We believe that the result has demonstrated good feasibility of linac-based high brightness X-ray sources via laser-electron Compton scatterings.

43 PARTICLE ACCELERATORS↗

Form factor of pNIPAM microgels in overpacked states

We study the form factor of thermoresponsive microgels based on poly(N-isopropylacrylamide) at high generalized volume fractions, ζ, where the particles must shrink or interpenetrate to fit into the available space. Small-angle neutron scattering with contrast matching techniques is used to determine the particle form factor. We find that the particle size is constant up to a volume fraction roughly between random close packing and space filling. Beyond this point, the particle size decreases with increasing particle concentration; this decrease is found to occur with little interpenetration. Noteworthily, the suspensions remain liquid-like for ζ larger than 1, emphasizing the importance of particle softness in determining suspension behavior.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-F-I-10: Spatially Local Statistics for Adaptive Image Filtering

Purpose: To facilitate adaptive image filtering operations, addressing spatial variations in both noise and signal. Such issues are prevalent in cone-beam projections, where physical effects such as X-ray scattering result in spatially variant noise, violating common assumptions of homogeneous noise and challenging conventional filtering approaches to signal extraction and noise suppression. Methods: We present a computational mechanism for probing into and quantifying the spatial variance of noise throughout an image. The mechanism builds a pyramid of local statistics at multiple spatial scales; local statistical information at each scale includes (weighted) mean, median, standard deviation, median absolute deviation, as well as histogram or dynamic range after local mean/median shifting. Based on inter-scale differences of local statistics, the spatial scope of distinguishable noise variation is detected in a semi- or un-supervised manner. Additionally, we propose and demonstrate the incorporation of such information in globally parametrized (i.e., non-adaptive) filters, effectively transforming the latter into spatially adaptive filters. The multi-scale mechanism is materialized by efficient algorithms and implemented in parallel CPU/GPU architectures. Results: We demonstrate the impact of local statistics for adaptive image processing and analysis using cone-beam projections of a Catphan phantom, fitted within an annulus to increase X-ray scattering. The effective spatial scope of local statistics calculations is shown to vary throughout the image domain, necessitating multi-scale noise and signal structure analysis. Filtering results with and without spatial filter adaptation are compared visually, illustrating improvements in imaging signal extraction and noise suppression, and in preserving information in low-contrast regions. Conclusion: Local image statistics can be incorporated in filtering operations to equip them with spatial adaptivity to spatial signal/noise variations. An efficient multi-scale computational mechanism is developed to curtail processing latency. Spatially adaptive filtering may impact subsequent processing tasks such as reconstruction and numerical gradient computations for deformable registration. NIH Grant No. R01-184173.

60 APPLIED LIFE SCIENCES↗

The influence of substrate temperature and Al mobility on the microstructural evolution of magnetron sputtered ternary Ti-Al-N thin films

Ternary Ti-Al-N films were deposited onto Al{sub 2}O{sub 3} (0001) substrates by reactive cosputtering from elemental Ti and Al targets and analyzed by in situ and ex situ x-ray scattering, Rutherford backscattering spectroscopy, transmission electron microscopy, and x-ray photoemission spectroscopy. The deposition parameters were set to values that yield Ti:Al:N ratios of 2:1:1 and 4:1:3 at room temperature. 2TiAlN depositions at 675 deg. C result in epitaxial Ti{sub 2}AlN growth with basal planes parallel to the substrate surface. Nominal 4TiAl3N depositions at 675 deg. C and above, however, yield domain growth of TiN and Ti{sub 2}AlN due to Al loss to the vacuum. Depositions at a lower temperature of 600 deg. C yield films with correct 4:1:3 stoichiometry, but Ti{sub 4}AlN{sub 3} formation is prevented, supposedly by insufficient adatom mobility. Instead, an incoherent Ti{sub n+1}AlN{sub n} structure with random twinned stacking sequences n is obtained that exhibits both basal plane orientations parallel and nearly perpendicular to the substrate interface. X-ray photoemission spectroscopy shows that in contrast to stoichiometric nitrides the Al is metallically bonded and hence acts as twinning plane within the Ti{sub n+1}AlN{sub n} stackings. Domains with perpendicular basal plane orientation overgrow those with parallel orientation in a competitive growth mode. The resulting morphology is a combination of smooth-surface parallel-basal-plane-oriented domains interrupted by repeated facetted hillocklike features with perpendicular basal plane orientation.

36 MATERIALS SCIENCE↗

Scatter correction in cone-beam CT via a half beam blocker technique allowing simultaneous acquisition of scatter and image information

Purpose: X-ray scatter incurred to detectors degrades the quality of cone-beam computed tomography (CBCT) and represents a problem in volumetric image guided and adaptive radiation therapy. Several methods using a beam blocker for the estimation and subtraction of scatter have been proposed. However, due to missing information resulting from the obstruction of the blocker, such methods require dual scanning or dynamically moving blocker to obtain a complete volumetric image. Here, we propose a half beam blocker-based approach, in conjunction with a total variation (TV) regularized Feldkamp-Davis-Kress (FDK) algorithm, to correct scatter-induced artifacts by simultaneously acquiring image and scatter information from a single-rotation CBCT scan. Methods: A half beam blocker, comprising lead strips, is used to simultaneously acquire image data on one side of the projection data and scatter data on the other half side. One-dimensional cubic B-Spline interpolation/extrapolation is applied to derive patient specific scatter information by using the scatter distributions on strips. The estimated scatter is subtracted from the projection image acquired at the opposite view. With scatter-corrected projections where this subtraction is completed, the FDK algorithm based on a cosine weighting function is performed to reconstruct CBCT volume. To suppress the noise in the reconstructed CBCT images produced by geometric errors between two opposed projections and interpolated scatter information, total variation regularization is applied by a minimization using a steepest gradient descent optimization method. The experimental studies using Catphan504 and anthropomorphic phantoms were carried out to evaluate the performance of the proposed scheme. Results: The scatter-induced shading artifacts were markedly suppressed in CBCT using the proposed scheme. Compared with CBCT without a blocker, the nonuniformity value was reduced from 39.3% to 3.1%. The root mean square error relative to values inside the regions of interest selected from a benchmark scatter free image was reduced from 50 to 11.3. The TV regularization also led to a better contrast-to-noise ratio. Conclusions: An asymmetric half beam blocker-based FDK acquisition and reconstruction technique has been established. The proposed scheme enables simultaneous detection of patient specific scatter and complete volumetric CBCT reconstruction without additional requirements such as prior images, dual scans, or moving strips.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of filling materials on the microstructure and properties of hybrid laser welded Al-Mg-Si alloys joints

Highlights: • A serious comparison was made on the hybrid laser welded AA6061-T6 joint with different filling materials. • The microstructure of the welded joint was characterized using EBSD and SEM. • A strength model was successfully built to predict the strength of the hybrid laser welded AA6061-t6 joint. • The study shed new insights on how to select appropriate filling materials when using hybrid laser welding. - Abstract: A serious investigation was conducted to examine the influence of filling materials on the microstructure and properties of hybrid laser welded AA6061-T6 joints. The results of the tensile tests showed that the welded joint with ER4043 filling materials had higher tensile strength than that with ER5356 filling material. Based on the results obtained a strength model was built to predict and explain the enhancement of the yield strength of the hybrid laser welded AA6061-T6 joint with different welding wires. In contrast to the tensile strength, the ER4043 joint showed lower fatigue strength than that of the ER5356 joint due to extensive presence of micropores in fusion zone. Further, the corrosion experiment illustrated that the ER4043 joint had poorer resistance to the corrosive attack under 3.5% NaCl solution. A summary was made on the performance of both welded joints to shed new insights on selecting appropriate filling materials when welding AA6061-T6 by hybrid laser welding method.

36 MATERIALS SCIENCE↗

Gas Permeation and Separation Characteristics of Microporous TpHz COF Membranes Synthesized by Substrate-Assisted Interfacial Polymerization

Microporous two-dimensional covalent organic framework (2D COF) membranes offer promise for gas separation applications, but their gas transport mechanism remains unclear. In this study, a TpHz 2D COF membrane supported on a macroporous nylon substrate is prepared by substrate-assisted interfacial polymerization under mild conditions. The formation of a continuous and dense thin (~300 nm thick) TpHz layer is confirmed by scanning electron microscopy and Fourier transform infrared spectroscopy. Characterization by X-ray diffraction, grazing incidence wide-angle X-ray scattering, and N 2 porosimetry qualitatively reveals the microstructures of the supported TpHz membranes, i.e., they comprise partially oriented 2D COF lamellar crystallites with moderate crystallinity in an eclipsed (AA) stacking geometry, centering the effective membrane pore size distribution at ~1.1 nm. Further, single gas permeation data show that the transport of common molecular gases, including H 2 , He, CH 4 , N 2 , and CO 2 , through the synthesized TpHz membranes follows the Knudsen transport mechanism, where single gas permeance decreases with an increasing molecular weight and permeation temperature. Binary gas separation results show that in the equimolar CO 2 /N 2 mixture, the presence of the CO 2 surface flow slightly hinders the N 2 flow at room temperature due to the reduced membrane channel size by the adsorbed CO 2 gas layer on TpHz’s pore wall. In contrast, permeation of the equimolar CH 4 /N 2 binary mixture does not exhibit a discernible surface flow of both gases due to their much lower gas uptake on TpHz, and their transport mechanism follows Knudsen-like behavior.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Two-dimensional spatiotemporal focusing of femtosecond pulses and its applications in microscopy

We demonstrate and theoretically analyze the two-dimensional spatiotemporal focusing of femtosecond pulses by utilizing a two-dimensional spectral disperser. Compared with spatiotemporal focusing with a diffraction grating, it can achieve widefield illumination with better sectioning ability for a multiphoton excitation process. By utilizing paraxial approximation, our analytical method improves the axial confinement ability and identifies that the free spectra range (FSR) of the two-dimensional spectral disperser affects the out-of-focus multiphoton excitation intensity due to the temporal self-imaging effect. Based on our numerical simulation, a FSR of 50 GHz is necessary to reduce the out-of-focus two-photon excitation by 2 orders of magnitude compared with that in a grating-based spatiotemporal focusing scheme for a 90-fs excitation laser pulse. We build a two-dimensional spatiotemporal focusing microscope using a virtually imaged phased array and achieve an axial resolution of 1.3 μm, which outperforms the resolution of conventional spatiotemporal focusing using a grating by a factor of 1.7, and demonstrate better image contrast inside a tissue-like phantom.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Boron nitride on SiC(0001)

Here, in the field of van der Waals heterostructures, the twist angle between stacked two-dimensional layers has been identified to be of utmost importance for the properties of the heterostructures. In this context, we previously reported the growth of a single layer of unconventionally oriented epitaxial graphene that forms in a surfactant atmosphere [F. C. Bocquet et al., Phys. Rev. Lett. 125, 106102 (2020)]. The resulting G-R0° layer is aligned with the SiC lattice, and hence represents an important milestone towards high-quality twisted bilayer graphene, a frequently investigated model system in this field. Here, we focus on the surface structures obtained in the same surfactant atmosphere, but at lower preparation temperatures at which a boron nitride template layer forms on SiC(0001). In a comprehensive study based on complementary experimental and theoretical techniques, we find—in contrast to the literature—that this template layer is a hexagonal B x N y layer, but not high-quality hBN. It is aligned with the SiC lattice and gradually replaced by low-quality graphene in the 0° orientation of the B x N y template layer upon annealing.

36 MATERIALS SCIENCE↗

Variable-permittivity linear inverse problem for the H(sub z)-polarized case

The H(sub z)-polarized inverse problem has rarely been studied before due to the complicated way in which the unknown permittivity appears in the wave equation. This problem is equivalent to the acoustic inverse problem with variable density. We have recently reported the solution to the nonlinear variable-permittivity H(sub z)-polarized inverse problem using the Born iterative method. Here, the linear inverse problem is solved for permittivity (epsilon) and permeability (mu) using a different approach which is an extension of the basic ideas of diffraction tomography (DT). The key to solving this problem is to utilize frequency diversity to obtain the required independent measurements. The receivers are assumed to be in the far field of the object, and plane wave incidence is also assumed. It is assumed that the scatterer is weak, so that the Born approximation can be used to arrive at a relationship between the measured pressure field and two terms related to the spatial Fourier transform of the two unknowns, epsilon and mu. The term involving permeability corresponds to monopole scattering and that for permittivity to dipole scattering. Measurements at several frequencies are used and a least squares problem is solved to reconstruct epsilon and mu. It is observed that the low spatial frequencies in the spectra of epsilon and mu produce inaccuracies in the results. Hence, a regularization method is devised to remove this problem. Several results are shown. Low contrast objects for which the above analysis holds are used to show that good reconstructions are obtained for both permittivity and permeability after regularization is applied.

Moghaddam, M.↗

Diagnostics, Control and Performance Parameters for the BELLA High Repetition Rate Petawatt Class Laser

A laser system producing controllable and stable pulses with high power and ultrashort duration at high repetition rate is a key component of a high energy laser-plasma accelerator (LPA). Precise characterization and control of laser properties are essential to understanding laser-plasma interactions required to build a 10-GeV class LPA. This study discusses the diagnostics, control and performance parameters of a 1 Hz, 1 petawatt (PW) class laser at the Berkeley Lab Laser Accelerator (BELLA) facility. The BELLA PW laser provided up to 46 J on target with a 1% level energy fluctuation and 1.3-μrad pointing stability. The spatial profile was measured and optimized by using a camera, wavefront sensor, and deformable mirror (ILAO system). The focus waist was measured to be r 0 = 53 μm and the fraction of energy within the circular area defined by the first minimum of the diffraction pattern (r = 67 μm) was 0.75. The temporal profile was controlled via the angle of incidence on a stretcher and a compressor, as well as an acousto-optic programmable dispersive. The temporal pulse shape was measured to be about 33 fs in full width at half maximum (WIZZLER and GRENOUILLE diagnostics). In order to accurately evaluate peak intensity, the energy-normalized peak fluence, and energy-normalized peak power were analyzed for the measured spatial and temporal mode profiles, and were found to be 15 kJ/(cm 2 J) with 6% fluctuation (standard deviation) and 25 TW/J with 5% fluctuation for 46-J on-target energy, respectively. This yielded a peak power of 1.2 PW and a peak intensity of 17×10 18 W/cm 2 with 8% fluctuation. A method to model the pulse shape for arbitrary compressor grating distance with high accuracy was developed. The pulse contrast above the amplified spontaneous emission pedestal was measured by SEQUOIA and found to be better than 10 9 . The first order spatiotemporal couplings (STCs) were measured with GRENOUILLE, and a simulation of the pulse's evolution at the vicinity of the target was presented. A maximum pulse front tilt angle of less than 7 mrad was achieved. The reduction of the peak power caused by the first order STCs was estimated to be less than 1%. Finally, the capabilities described in this paper are essential for generation of high quality electron beams.

47 OTHER INSTRUMENTATION↗

Synchrotron-based coherent scatter x-ray projection imaging using an array of monoenergetic pencil beams

Traditional projection x-ray imaging utilizes only the information from the primary photons. Low-angle coherent scatter images can be acquired simultaneous to the primary images and provide additional information. In medical applications scatter imaging can improve x-ray contrast or reduce dose using information that is currently discarded in radiological images to augment the transmitted radiation information. Other applications include non-destructive testing and security. A system at the Canadian Light Source synchrotron was configured which utilizes multiple pencil beams (up to five) to create both primary and coherent scatter projection images, simultaneously. The sample was scanned through the beams using an automated step-and-shoot setup. Pixels were acquired in a hexagonal lattice to maximize packing efficiency. The typical pitch was between 1.0 and 1.6 mm. A Maximum Likelihood-Expectation Maximization-based iterative method was used to disentangle the overlapping information from the flat panel digital x-ray detector. The pixel value of the coherent scatter image was generated by integrating the radial profile (scatter intensity versus scattering angle) over an angular range. Different angular ranges maximize the contrast between different materials of interest. A five-beam primary and scatter image set (which had a pixel beam time of 990 ms and total scan time of 56 min) of a porcine phantom is included. For comparison a single-beam coherent scatter image of the same phantom is included. The muscle-fat contrast was 0.10 {+-} 0.01 and 1.16 {+-} 0.03 for the five-beam primary and scatter images, respectively. The air kerma was measured free in air using aluminum oxide optically stimulated luminescent dosimeters. The total area-averaged air kerma for the scan was measured to be 7.2 {+-} 0.4 cGy although due to difficulties in small-beam dosimetry this number could be inaccurate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗