Search NASA⌕ Search

SEARCH · Search NASA

Results for “method of cells”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Tissue Photolithography

Tissue lithography will enable physicians and researchers to obtain macromolecules with high purity (greater than 90 percent) from desired cells in conventionally processed, clinical tissues by simply annotating the desired cells on a computer screen. After identifying the desired cells, a suitable lithography mask will be generated to protect the contents of the desired cells while allowing destruction of all undesired cells by irradiation with ultraviolet light. The DNA from the protected cells can be used in a number of downstream applications including DNA sequencing. The purity (i.e., macromolecules isolated form specific cell types) of such specimens will greatly enhance the value and information of downstream applications. In this method, the specific cells are isolated on a microscope slide using photolithography, which will be faster, more specific, and less expensive than current methods. It relies on the fact that many biological molecules such as DNA are photosensitive and can be destroyed by ultraviolet irradiation. Therefore, it is possible to protect the contents of desired cells, yet destroy undesired cells. This approach leverages the technologies of the microelectronics industry, which can make features smaller than 1 micrometer with photolithography. A variety of ways has been created to achieve identification of the desired cell, and also to designate the other cells for destruction. This can be accomplished through chrome masks, direct laser writing, and also active masking using dynamic arrays. Image recognition is envisioned as one method for identifying cell nuclei and cell membranes. The pathologist can identify the cells of interest using a microscopic computerized image of the slide, and appropriate custom software. In one of the approaches described in this work, the software converts the selection into a digital mask that can be fed into a direct laser writer, e.g. the Heidelberg DWL66. Such a machine uses a metalized glass plate (with chrome metallization) on which there is a thin layer of photoresist. The laser transfers the digital mask onto the photoresist by direct writing, with typical best resolution of 2 micrometers. The plate is then developed to remove the exposed photoresist, which leaves the exposed areas susceptible to chemical chrome etch. The etch removes the unprotected chrome. The rest of the photoresist is then removed, by either ultraviolet organic solvent or over-development. The remaining chrome pattern is quickly oxidized by atmospheric exposure (typically within 30 seconds). The ready chrome mask is now applied to the tissue slide and aligned manually, or using automatic software and pre-designed alignment marks. The slide plate sandwich is then exposed to UV to destroy the DNA of the unwanted cells. The slide and plate are separated and the slide is processed in a standard way to prepare for polymerase chain reaction (PCR) and potential identification of cancer sequences.

Wade, Lawrence A.↗

Interactions of efficiency and material requirements for terrestrial silicon solar cells

The transport velocity transformation method was used to analyze solar cell designs to determine optimum cell structures. It was found that low resistivity materials should be used up to the onset of Auger recombination; a properly designed three-layer structure permits base region approaching an ideal device in performance; and that higher resistivity front regions will need more sophisticated grid metallization structures than those used now. It was concluded that new features will provide idealized silicon cell structures yielding airmass 1 efficiencies in the 24-26.5% range, with real efficiencies near 22%.

Bowler, D. L.↗

Mechanical proof testing in cell processing

Fracture mechanics test methods are applied to evaluate the proof test characteristics of silicon Cz wafers. The results indicate that the strength distribution of silicon wafers is truncated by proof testing and no subcritical crack growth in silicon is observed during proof loading. Mechanical proof testing appears to be an effective method to eliminate weak samples before cell processing.

Chen, C. P.↗

Microspheres

Vital information on a person's physical condition can be obtained by identifying and counting the population of T-cells and B-cells, lymphocytes of the same shape and size that help the immune system protect the body from the invasion of disease. The late Dr. Alan Rembaum developed a method for identifying the cells. The method involved tagging the T-cells and B-cells with microspheres of different fluorescent color. Microspheres, which have fluorescent dye embedded in them, are chemically treated so that they can link with antibodies. With the help of a complex antibody/antigen reaction, the microspheres bind themselves to specific 'targets,' in this case the T-cells or B-cells. Each group of cells can then be analyzed by a photoelectronic instrument at different wavelengths emitted by the fluorescent dyes. Same concept was applied to the separation of cancer cells from normal cells. Microspheres were also used to conduct many other research projects. Under a patent license Magsphere, Inc. is producing a wide spectrum of microspheres on a large scale and selling them worldwide for various applications.

Source record↗

Graded bandgap perovskite solar cell

This disclosure provides systems, methods, and apparatus related to solar cells. In one aspect a solar cell includes a first electrode, a hole transport layer disposed on the first electrode, a first perovskite layer disposed on the hole transport layer, a cationic diffusion barrier disposed on the first perovskite layer, a second perovskite layer disposed on the cationic diffusion barrier, an electron transport layer disposed on the second perovskite layer, and a second electrode disposed on the electron transport layer. The first perovskite layer comprises a different perovskite than the second perovskite layer.

14 SOLAR ENERGY↗

Synthesis of TiO{sub 2} thin films using single molecular precursors by MOCVD method for dye-sensitized solar cells application and study on film growth mechanism

For dye-sensitized solar cells application, in this study, we have synthesized TiO{sub 2} thin films at deposition temperature in the range of 300–750 °C by metalorganic chemical vapor deposition (MOCVD) method. Titanium(IV) isopropoxide, (TIP, Ti(O{sup i}Pr){sub 4}) and Bis(dimethylamido)titanium diisopropoxide, (BTDIP, (Me{sub 2}N){sub 2}Ti(O{sup i}Pr){sub 2}) were used as single source precursors that contain Ti and O atoms in the same molecule, respectively. Crack-free, highly oriented TiO{sub 2} polycrystalline thin films with anatase phase were deposited on Si(1 0 0) with TIP at temperature as low as 450 °C. XRD and TED data showed that below 500 °C, the TiO{sub 2} thin films were dominantly grown in the [2 1 1] direction on Si(1 0 0), whereas with increasing the deposition temperature to 700 °C, the main film growth direction was changed to [2 0 0]. Above 700 °C, however, rutile phase TiO{sub 2} thin films have only been obtained. In the case of BTDIP, on the other hand, only amorphous film was grown on Si(1 0 0) below 450 °C while a highly oriented anatase TiO{sub 2} film in the [2 0 0] direction was obtained at 500 °C. With further increasing deposition temperatures over 600 °C, the main film growth direction shows a sequential change from rutile [1 0 1] to rutile [4 0 0], indicating a possibility of getting single crystalline TiO{sub 2} film with rutile phase. This means that the precursor together with deposition temperature can be one of important parameters to influence film growth direction, crystallinity as well as crystal structure. To investigate the CVD mechanism of both precursors in detail, temperature dependence of growth rate was also carried out, and we then obtained different activation energy of deposition to be 77.9 and 55.4 kJ/mol for TIP and BTDIP, respectively. Also, we are tested some TiO{sub 2} film synthesized with BTDIP precursor to apply dye-sensitized solar cell.

36 MATERIALS SCIENCE↗

Rational anode design for protonic ceramic fuel cells by a one-step phase inversion method

A one-step phase inversion method was applied to fabricate an optimized anode structure for protonic ceramic fuel cells (PCFCs). The phase inversion process utilized raw starting chemicals, instead of crystalline BaCe 0.7 Z r0.1 Y 0.1 Yb 0.1 O 3-δ (BCZYYb) powder in an energy and time saving process. The resulting large and fingerlike pores exhibited enhanced performance as compared to the disordered pores produced by conventional preparation of anode structures using dry pressing methods. The electrochemical performance of the rational designed anode supported cell were 491, 402, 302 and 200 mW cm -2 at 700, 650, 600 and 550 °C, respectively, which was nearly twice than the cell with dry pressing anode. An equivalent circuit modeling method was used to separate the anode polarization resistance from the single cell, confirming that the overall cell performance improvements were attributed to microstructural modifications of the anode by the phase inversion process. The one-step phase inversion method demonstrated great promise for improved processing of fuel cells and separation membranes.

25 ENERGY STORAGE↗

Label-free cell-substrate adhesion imaging on plasmonic nanocup arrays

Cell adhesion is a crucial biological and biomedical parameter defining cell differentiation, cell migration, cell survival, and state of disease. Because of its importance in cellular function, several tools have been developed in order to monitor cell adhesion in response to various biochemical and mechanical cues. However, there remains a need to monitor cell adhesion and cell-substrate separation with a method that allows real-time measurements on accessible equipment. In this article, we present a method to monitor cell-substrate separation at the single cell level using a plasmonic extraordinary optical transmission substrate, which has a high sensitivity to refractive index changes at the metal-dielectric interface. We show how refractive index changes can be detected using intensity peaks in color channel histograms from RGB images taken of the device surface with a brightfield microscope. Furthermore, this allows mapping of the nonuniform refractive index pattern of a single cell cultured on the plasmonic substrate and therefore high-throughput detection of cell-substrate adhesion with observations in real time.

47 OTHER INSTRUMENTATION↗

Fabrication and testing of sealed silver-zinc cells

A number of Type HS40-7 sealed silver-zinc cells and experimental 40AH sealed silver-zinc cells were fabricated. Cells of each experimental group contained one variation from the standard configuration (HS40-7) cell. Cells from each of five experimental cell groups and cells of the standard configuration were tested to characterize voltage and capacity performance at various discharge rates. The test cells were then subjected to 100 percent DOD Cycle Life Testing at 22 C. Results indicate that material and/or process variations are available which will improve both performance and cycle life of the existing 40 ampere-hour sealed silver-zinc cell configurations. The average cycle life to 50 percent loss of nominal capacity in cells from two (2) of the experimental groups was 150 - 165 cycles. A series of 12 ampere-hour cells was fabricated and tested as part of a program to incorporate the 40AH sealed silver-zinc cell fabrication technology into a cell of smaller size. Base-line configuration cells and experimental variations were produced using the HS40-7 cell fabrication and processing methods adapted to the smaller cell size.

Donnel, C. P., III↗

Human cell culture in a space bioreactor

Microgravity offers new ways of handling fluids, gases, and growing mammalian cells in efficient suspension cultures. In 1976 bioreactor engineers designed a system using a cylindrical reactor vessel in which the cells and medium are slowly mixed. The reaction chamber is interchangeable and can be used for several types of cell cultures. NASA has methodically developed unique suspension type cell and recovery apparatus culture systems for bioprocess technology experiments and production of biological products in microgravity. The first Space Bioreactor was designed for microprocessor control, no gaseous headspace, circulation and resupply of culture medium, and slow mixing in very low shear regimes. Various ground based bioreactors are being used to test reactor vessel design, on-line sensors, effects of shear, nutrient supply, and waste removal from continuous culture of human cells attached to microcarriers. The small Bioreactor is being constructed for flight experiments in the Shuttle Middeck to verify systems operation under microgravity conditions and to measure the efficiencies of mass transport, gas transfer, oxygen consumption and control of low shear stress on cells.

Morrison, Dennis R.↗

Capillary photoelectrode structures for photoelectrochemical and photocatalytic cells

Photocatalytic structures having a capillary-force based electrolyte delivery system are provided. Also provided are photoelectrochemical and photocatalytic cells incorporating the structures and methods for using the cells to generate hydrogen and/or oxygen from water. The photocatalytic structures use an electrolyte-transporting strip comprising a porous network of cellulose nanofibers to transport electrolyte from a body of the electrolyte to a porous photoelectrode or a porous photocatalytic substrate via capillary force.

14 SOLAR ENERGY↗

Particle compositions with a pre-selected cell internalization mode

A method of formulating a particle composition having a pre-selected cell internalization mode involves selecting a target cell having surface receptors and obtaining particles that have i) surface moieties, that have an affinity for or are capable of binding to the surface receptors of the cell and ii) a preselected shape, where a surface distribution of the surface moieties on the particles and the shape of the particles are effective for the pre-selected cell internalization mode.

Decuzzi, Paolo↗

High-pressure in situ density measurement of low-Z noncrystalline materials with a diamond-anvil cell by an x-ray absorption method

We have developed techniques for high-pressure in situ density measurement of low-Z noncrystalline materials with a diamond-anvil cell (DAC) by an x-ray absorption method. In DAC experiments, accurate determination of the sample thickness is difficult. Moreover, since the sample in a DAC is thin and the interaction between low-Z materials and x rays is small, not the sample but the anvils absorb most of x rays. This makes the measurement quite difficult. We have overcome such difficulties and have successfully measured the density of SiO{sub 2} glass, a low-Z noncrystalline material, as a function of pressure up to 35 GPa.

36 MATERIALS SCIENCE↗

Raman scattering characterization of space solar cell structures

A contactless method for the determination of the free-carrier density and the composition distribution across the thickness of 3-5 multi-layer solar cell structures, using the Raman scattering method, is developed. The method includes a step analysis of Raman spectra from optical phonons and phonon-plasmon modes of different layers. The method provides simultaneous measurements of the element composition and the thickness of the structure's layers together with the free-carrier density. The results of measurements of the free-carrier density composition distributions of the liquid phase epitaxy grown AlGaAs/GaAs and GaSb solar cell structures are presented and discussed.

Mintairov, Alexander M.↗

Unit cell dilation technique for analyzing dilatometry data in microalloyed steels

Highlights: • Lever rule is not an adequate method to analyze dilatometry data. • A method called “Unit Cell Dilation” is developed to analyze the dilatometry data. • The new method calculates phase fractions while accounting for chemical changes during diffusive phase transformation. - Abstract: Dilatometry is the most accurate and common method for measuring the kinetics of phase transformations in solid specimens. Despite the development of a more accurate technique, an inferior method, i.e., the lever rule, is widely used in the scientific community to interpret raw dilatometry data. This paper introduces a sound mathematical approach to modeling the physical phenomena of phase transformations, named continuous sequential phase transformation (CSPT). CSPT is used in creating an algorithm called unit cell dilation (UCD) that is used for analyzing the continuous phase transformation of two microalloyed steels. Results show that the UCD algorithm generates quantitative data for the phase content of the steel that is in good agreement with metallographic observations. The source code for an implementation of the UCD algorithm is distributed under GPL-3.0 license and available for download at (https://github.com/Nassehk/Dilatometry-analysis.git).

36 MATERIALS SCIENCE↗