Search NASA⌕ Search

SEARCH · Search NASA

Results for “refractivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

X-ray phase contrast and absorption imaging for the quantification of transient cavitation in high-speed nozzle flows

In this work, high-flux synchrotron radiation has been employed in a time-resolved manner to characterise the distinct topology features and dynamics of different cavitation regimes arising in a throttle orifice with an abrupt flow-entry contraction. Radiographs obtained though both X-ray phase- contrast and absorption imaging have been captured at 67,890 frames per second. The flow lied in the turbulent regime (Re=35,500), while moderate (CN=2.0) to well-established (CN=6.0) cavitation conditions were examined encompassing the cloud and vortical cavitation regimes with pertinent transient features, such as cloud-cavity shedding. X-ray Phase-Contrast Imaging (XPCI), exploiting the shift in the X-ray wave phase during interactions with matter, offers sharp-refractive index gradients in the interface region. Hence, it is suitable for capturing fine morphological fluctuations of transient cavitation structures. Nevertheless, the technique cannot provide information on the quantity of vapour within the orifice. Such data have been obtained utilising absorption imaging, where beam attenuation is not associated with scattering and refraction events, and hence can be explicitly correlated with the projected vapour thickness in line-of-sight measurements. A combination of the two methods is proposed, as it has been found is capable of quantifying the vapour content arising in the complex nozzle flow, while also faithfully illustrating the dynamics of the highly-transient cavitation features.

42 ENGINEERING↗

Observation of a highly conductive warm dense state of water with ultrafast pump–probe free-electron-laser measurements

The electrical conductivity of water under extreme temperatures and densities plays a central role in modeling planetary magnetic fields. Experimental data are vital to test theories of high-energy-density water and assess the possible development and presence of extraterrestrial life. These states are also important in biology and chemistry studies when specimens in water are confined and excited using ultrafast optical or free-electron lasers (FELs). Here we utilize femtosecond optical lasers to measure the transient reflection and transmission of ultrathin water sheet samples uniformly heated by a 13.6 nm FEL approaching a highly conducting state at electron temperatures exceeding 20 000 K. The experiment probes the trajectory of water through the high-energy-density phase space and provides insights into changes in the index of refraction, charge carrier densities, and AC electrical conductivity at optical frequencies. At excitation energy densities exceeding 10 MJ/kg, the index of refraction falls to n = 0.7, and the thermally excited free-carrier density reaches ne = 5 × 1027 m−3, which is over an order of magnitude higher than that of the electron carriers produced by direct photoionization. Significant specular reflection is observed owing to critical electron density shielding of electromagnetic waves. The measured optical conductivity reaches 2 × 104 S/m, a value that is one to two orders of magnitude lower than those of simple metals in a liquid state. At electron temperatures below 15 000 K, the experimental results agree well with the theoretical calculations using density-functional theory/molecular-dynamics simulations. With increasing temperature, the electron density increases and the system approaches a Fermi distribution. In this regime, the conductivities agree better with predictions from the Ziman theory of liquid metals.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Modeling the spectral modification of lower hybrid wave in the presence of drift-wave type density fluctuation in the scrape-off-layer of the EAST tokamak

In this work, the spectrum change of the lower hybrid (LH) waves caused by a low-frequency density fluctuation in the scrape-off-layer is studied by applying the wave scattering model developed by Bonoli and Ott [Phys. Fluids 25, 359 (1982)] via a Monte Carlo method. A ray-tracing model specific to this purpose is developed to evaluate the probability distribution of both the poloidal refractive index (N θ ) and the parallel refractive index (N ∥ ) of the LH wave at the last closed flux surface (LCFS).The probability distributions of N ∥ and N θ at the LCFS are studied using the EAST parameters as a function of wave frequency, the initial N ∥ , and the polar injection position, which may influence the lower hybrid current drive efficiency.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-order ( N = 4–6) multiphoton absorption and mid-infrared Kerr nonlinearity in GaP, ZnSe, GaSe, and ZGP crystals

We report a study of high-order multiphoton absorption, nonlinear refraction, and their anisotropy in four notable mid-infrared χ (2) crystals: GaP, ZnSe, GaSe, and ZGP using femtosecond pulses at 2.35 μm with peak intensity in excess of 200 GW/cm 2 . We found that the nonlinear absorption obeys a perturbation model with multiphoton absorption (MPA) orders from N = 4–6, in agreement with the bandgaps of the crystals. A study of the role of free carrier absorption, performed by changing the pulse duration from 30 to 70 fs while maintaining a constant peak intensity, showed that, at our intensity levels, free carriers generated during the MPA process absorb much more strongly than would be expected from their known linear absorption cross section. Possible mechanisms for this anomalous behavior are high-field effects, such as intravalley scattering in the conduction band and absorption to higher lying bands. Nonlinear refractive indices were measured using (i) closed aperture Z-scan and (ii) spectral broadening due to self-phase modulation, both methods agreeing with each other.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Simulating the filamentation of smoothed laser beams with three-dimensional nonlinear dynamics

In a plasma, the ponderomotive force of an inhomogeneous electromagnetic field expels plasma from regions of high intensity. When a laser propagates through a plasma, this force creates density wells that subsequently modify the index of refraction. The beam refracts and focuses into these wells and may filament. In extreme cases, the laser beam will spray due to increasing angular divergence of the beam. The threshold for ponderomotive self-focusing is well established for isolated laser hotspots or speckles. Here, we define a practical threshold for characterizing the filamentation of thousands of speckles that are found in the focal plane of high-power laser beams spatially smoothed with random phase plates as used at high energy and power laser facilities studying inertial confinement fusion. This threshold is tested against three-dimensional simulations of speckled laser light propagating through plasma. Four metrics are applied to assess filamentation: the fraction of power above five times the average intensity, an effective f-number, the mean-squared perpendicular wavenumber, and the fraction of rarefied density with deviation from the initial density exceeding | δn/ n| = 0.1. The speckled beams studied are generated by random phase plates, both with and without additional polarization smoothing, in a parameter regime of relevance to indirect drive experiments. While filamentation has been discussed extensively in the literature, we believe this to be the first published simulation study with three-dimensional nonlinear hydrodynamics that addresses the onset threshold of ponderomotive filamentation and establishes the lengths and time scales necessary to reach a statistical steady state.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Current advances on Talbot–Lau x-ray imaging diagnostics for high energy density experiments (invited)

Talbot–Lau x-ray interferometry is a refraction-based diagnostic that can map electron density gradients through phase-contrast methods. The Talbot–Lau x-ray deflectometry (TXD) diagnostics have been deployed in several high energy density experiments. To improve diagnostic performance, a monochromatic TXD was implemented on the Multi-Tera Watt (MTW) laser using 8 keV multilayer mirrors (Δθ/θ = 4.5%-5.6%). Copper foil and wire targets were irradiated at 10 14 –10 15 W/cm 2 . Laser pulse length (~10 to 80 ps) and backlighter target configurations were explored in the context of Moiré fringe contrast and spatial resolution. Foil and wire targets delivered increased contrast <30%. The best spatial resolution (<6 μm) was measured for foils irradiated 80° from the surface. Further TXD diagnostic capability enhancement was achieved through the development of advanced data postprocessing tools. The Talbot Interferometry Analysis (TIA) code enabled x-ray refraction measurements from the MTW monochromatic TXD. Additionally, phase, attenuation, and dark-field maps of an ablating x-pinch load were retrieved through TXD. The images show a dense wire core of ~60 μm diameter surrounded by low-density material of ~40 μm thickness with an outer diameter ratio of ~2.3. Attenuation at 8 keV was measured at ~20% for the dense core and ~10% for the low-density material. Instrumental and experimental limitations for monochromatic TXD diagnostics are presented. Enhanced postprocessing capabilities enabled by TIA are demonstrated in the context of high-intensity laser and pulsed power experimental data analysis. Significant advances in TXD diagnostic capabilities are presented. Furthermore, these results inform future diagnostic technique upgrades that will improve the accuracy of plasma characterization through TXD.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nonlinear optical properties of lanthanum titanate glasses prepared by levitation melting

Lanthanum titanate glasses (17 La 2 O 3 -83 TiO 2 ) are fabricated via aerodynamic levitation melting. Here, nonlinear refraction and absorption were measured with the Z scan technique using ps optical pulses at 532 nm wavelength with peak intensities in the range of 0.25–2.5 GW/cm 2 . The two-photon absorption coefficient (β) and the effective nonlinear refraction coefficient (⁠$n^{eff}_{2}$) are found to be, respectively, 2.19 cm/GW and 152 × 10 -16 cm 2 /W (85 × 10 -13 esu). The Raman gain is measured to be 106 × 10 -11 cm/W. The nonlinearity strength is found to be nearly 60 times larger in lanthanum titanate glasses relative to silica.

36 MATERIALS SCIENCE↗

Exact wave solver for nonparaxial laser beam propagation

Simulations of inertial confinement fusion (ICF) experiments require high-fidelity models for laser beam propagation in a nonuniform plasma with varying index of refraction. We describe a new numerical wave solver that is applicable to centimeter-scale length plasmas encountered in indirect drive ICF applications. The one-way Helmholtz equation (OHE) generalizes the time-harmonic paraxial wave equation to large angles. Here, we present a methodology to numerically evaluate the exact solution to the OHE. This solution is computed by analytically advancing eigenfunctions of the one-way Helmholtz operator along a propagation direction and is applicable to any given index of a refraction profile. We compare our exact method with a commonly used approximate split-step technique for solving the OHE. As a test problem, we consider nonparaxial propagation of Gaussian and speckled beams in a plasma density channel with internal reflection. We find that the split-step approach incurs significant errors compared to the exact solution computed using the novel algorithm.

Belyaev, Mikhail A. (ORCID:0000000224908887)↗

Evaluation of current density measurement methods for high-current, low-beta electron beams

Recent current density measurements with a low-beta electron beam (β=0.5-0.75) are strongly affected by electron scatter and Cherenkov limits. These invasive measurements are heavily influenced by the electron energy and the intercepting material properties: density, index of refraction, and atomic number. We evaluate various measurement methods, including x-ray scintillation and Cherenkov emission. To optimize the x-ray scintillation technique for this energy regime, metal foils of differing atomic number (Z) and thickness were placed upstream of a scintillation screen. We have selected Cherenkov emitters, based on a material refractive index, in order to differentiate the contributions from electron scatter and produced fluorescence, Cherenkov emission, and total internal reflection. The observed distributions for both approaches are verified through MCNP6®. Additionally, the simulations provide insight as to what physical processes dominate the measured distribution. We conclude by determining the limits and optimal measurement range for each measurement technique.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Reconstruction of 2D line-integrated electron density using angular filter refractometry and a fast marching Eikonal solver

Refraction of an optical probe beam by a plasma can be measured with angular filter refractometry (AFR), which produces an image of the beam’s 2D spatial profile that contains intensity contours corresponding to curves of constant refraction angle. Further analysis is required to reconstruct the underlying line-integrated electron density. Most prior efforts to calculate density from AFR data have been limited to 1D analysis or forward-fitting techniques. Here, in this paper, we detail the use of a fast-marching Eikonal solver to directly invert AFR data and obtain the full 2D line-integrated electron density. The analysis method is first verified with synthetic data and then applied to experimental measurements of single and colliding plasma plumes collected at the OMEGA EP Laser Facility. The calculated densities agree with 1D results and are shown to be consistent with the original AFR measurements via forward modeling. We also discuss ways to improve the precision of this technique.

McCluskey, B. [Princeton Univ., NJ (United States)↗

SPLAT II: An Aircraft Compatible, Ultra-Sensitive, High Precision Instrument for In-Situ Characterization of the Size and Composition of Fine and Ultrafine Particles

The properties of aerosols depend on the size and internal compositions of the individual particles. The vast majority of atmospheric aerosols are smaller than 200 nm, yet the single particle mass spectrometers, the only instruments that can characterize the size and internal compositions of individual particles, typically detect these small particles with extremely low efficiencies. In this paper we describe a new instrument called SPLAT II that provides unparalleled sensitivity to small particles, detecting 100% of particles that are larger than 125 nm and 40% of 100 nm particles. This instrument also brings an increase by a factor of 10 in temporal resolution, sizing up to 500 particles per second and characterizing the composition of up to 100 of them. SPLAT II uses a two-laser, two-step process to evaporate the particles and generate ions, producing high quality, reproducible mass spectra of the refractive and non-refractive aerosol fractions to yield the complete compositions of individual particles. The instrument control board provides for size dependent delays for lasers’ triggers to eliminate a size dependent hit rate. The mass spectra are recorded with 14-bit vertical resolution and analyzed using custom software packages. The instrument’s high sizing resolution and sensitivity makes it possible to combine it with the differential mobility analyzer(s) and measure particle size, composition, density, dynamic shape factor, hygroscopicity, and fractal dimension.

47 OTHER INSTRUMENTATION↗

THE MULTI-OBJECT, FIBER-FED SPECTROGRAPHS FOR THE SLOAN DIGITAL SKY SURVEY AND THE BARYON OSCILLATION SPECTROSCOPIC SURVEY

We present the design and performance of the multi-object fiber spectrographs for the Sloan Digital Sky Survey (SDSS) and their upgrade for the Baryon Oscillation Spectroscopic Survey (BOSS). Originally commissioned in Fall 1999 on the 2.5 m aperture Sloan Telescope at Apache Point Observatory, the spectrographs produced more than 1.5 million spectra for the SDSS and SDSS-II surveys, enabling a wide variety of Galactic and extra-galactic science including the first observation of baryon acoustic oscillations in 2005. The spectrographs were upgraded in 2009 and are currently in use for BOSS, the flagship survey of the third-generation SDSS-III project. BOSS will measure redshifts of 1.35 million massive galaxies to redshift 0.7 and Ly{alpha} absorption of 160,000 high redshift quasars over 10,000 deg{sup 2} of sky, making percent level measurements of the absolute cosmic distance scale of the universe and placing tight constraints on the equation of state of dark energy. The twin multi-object fiber spectrographs utilize a simple optical layout with reflective collimators, gratings, all-refractive cameras, and state-of-the-art CCD detectors to produce hundreds of spectra simultaneously in two channels over a bandpass covering the near-ultraviolet to the near-infrared, with a resolving power R = {lambda}/FWHM {approx} 2000. Building on proven heritage, the spectrographs were upgraded for BOSS with volume-phase holographic gratings and modern CCD detectors, improving the peak throughput by nearly a factor of two, extending the bandpass to cover 360 nm < {lambda} < 1000 nm, and increasing the number of fibers from 640 to 1000 per exposure. In this paper we describe the original SDSS spectrograph design and the upgrades implemented for BOSS, and document the predicted and measured performances.

79 ASTRONOMY AND ASTROPHYSICS↗

SCATTERING OF PULSAR RADIO EMISSION BY THE INTERSTELLAR PLASMA

We present simulations of scattering phenomena which are important in pulsar observations, but which are analytically intractable. The simulation code, which has also been used for solar wind and atmospheric scattering problems, is available from the authors. These simulations reveal an unexpectedly important role of dispersion in combination with refraction. We demonstrate the effect of analyzing observations which are shorter than the refractive scale. We examine time-of-arrival fluctuations in detail: showing their correlation with intensity and dispersion measure, providing a heuristic model from which one can estimate their contribution to pulsar timing observations, and showing that much of the effect can be corrected making use of measured intensity and dispersion. Finally, we analyze observations of the millisecond pulsar J0437-4715, made with the Parkes radio telescope, that show timing fluctuations which are correlated with intensity. We demonstrate that these timing fluctuations can be corrected, but we find that they are much larger than would be expected from scattering in a homogeneous turbulent plasma with isotropic density fluctuations. We do not have an explanation for these timing fluctuations.

79 ASTRONOMY AND ASTROPHYSICS↗

bicep2/KECK ARRAY. IV. OPTICAL CHARACTERIZATION AND PERFORMANCE OF THE bicep2 AND KECK ARRAY EXPERIMENTS

bicep2 and the Keck Array are polarization-sensitive microwave telescopes that observe the cosmic microwave background (CMB) from the South Pole at degree angular scales in search of a signature of inflation imprinted as B-mode polarization in the CMB. bicep2 was deployed in late 2009, observed for three years until the end of 2012 at 150 GHz with 512 antenna-coupled transition edge sensor bolometers, and has reported a detection of B-mode polarization on degree angular scales. The Keck Array was first deployed in late 2010 and will observe through 2016 with five receivers at several frequencies (95, 150, and 220 GHz). bicep2 and the Keck Array share a common optical design and employ the field-proven bicep1 strategy of using small-aperture, cold, on-axis refractive optics, providing excellent control of systematics while maintaining a large field of view. This design allows for full characterization of far-field optical performance using microwave sources on the ground. Here we describe the optical design of both instruments and report a full characterization of the optical performance and beams of bicep2 and the Keck Array at 150 GHz.

79 ASTRONOMY AND ASTROPHYSICS↗

Electromagnetic particle simulation of the effect of toroidicity on linear mode conversion and absorption of lower hybrid waves

Effects of toroidicity on linear mode conversion and absorption of lower hybrid (LH) waves in fusion plasmas have been studied using electromagnetic particle simulation. The simulation confirms that the toroidicity induces an upshift of parallel refractive index when LH waves propagate from the tokamak edge toward the core, which affects the radial position for the mode conversion between slow and fast LH waves. Furthermore, moving LH antenna launch position from low field side toward high field side leads to a larger upshift of the parallel refractive index, which helps the slow LH wave penetration into the tokamak core. The broadening of the poloidal spectrum of the wave-packet due to wave diffraction is also verified in the simulation. Both the upshift and broadening effects of the parallel spectrum of the wave-packet modify the parallel phase velocity and thus the linear absorption of LH waves by electron Landau resonance.

Physics↗

Comparison of different numerical treatments for x-ray phase tomography of soft tissue from differential phase projections

X-ray imaging of soft tissue is made difficult by their low absorbance. The use of x-ray phase imaging and tomography can significantly enhance the detection of these tissues and several approaches have been proposed to this end. Methods such as analyzer-based imaging or grating interferometry produce differential phase projections that can be used to reconstruct the 3D distribution of the sample refractive index. We report on the quantitative comparison of three different methods to obtain x-ray phase tomography with filtered back-projection from differential phase projections in the presence of noise. The three procedures represent different numerical approaches to solve the same mathematical problem, namely phase retrieval and filtered back-projection. It is found that obtaining individual phase projections and subsequently applying a conventional filtered back-projection algorithm produces the best results for noisy experimental data, when compared with other procedures based on the Hilbert transform. The algorithms are tested on simulated phantom data with added noise and the predictions are confirmed by experimental data acquired using a grating interferometer. The experiment is performed on unstained adult zebrafish, an important model organism for biomedical studies. The method optimization described here allows resolution of weak soft tissue features, such as muscle fibers.

Pelliccia, Daniele↗

Analysis of the density field around a supersonic conical projectile using quantitative schlieren

Quantitative schlieren imaging is a flow measurement technique that is capable of measuring density fields throughout refractive flowfields. The technique was applied here to measure the density field surrounding supersonic conical projectiles in free flight. Shock waves attached to a supersonic conical projectile offer a simple geometry with the well-established Taylor–Maccoll analytical flow solution to which these experimental measurements were compared. The schlieren images recorded a projection of the index of refraction field surrounding the 10° half-angle cones which was converted to density first through an Abel inversion and then the Gladstone–Dale law. Three Abel inversion methods—two-point, three-point, and arbitrary ray axisymmetric projection (ARAP)—were applied to deconvolute the three-dimensional flow within the constrained axisymmetric flow field. The resulting reconstructed density profiles were compared to the Taylor–Maccoll solution, parameterized by cone geometry and Mach number. The experimental density fields demonstrated strong agreement with the theoretical profiles. Experimental consistency was confirmed across various projectile speeds, demonstrating quantitative schlieren’s capability to accurately reconstruct the density of the flow field, even within the resolution constraints imposed by high-speed imaging. In conclusion, an assessment of experimental uncertainties in the density reconstruction was performed.

Abel Inversion↗

Wire, hybrid, and laser-cut X-pinches as Talbot–Lau backlighters for electron density diagnostics

Talbot–Lau x-ray deflectometry (TXD) enables refraction-based imaging for high-energy-density physics experiments, and thus, it has been studied and developed with the goal of diagnosing plasmas relevant to inertial confinement and magnetic liner inertial fusion. X-pinches, known for reliably generating fast (~1 ns), small (~1 µm) x-ray sources, were driven on the compact current driver generator for ablation structure and implosion studies (~200 kA, 150 ns) as a potential backlighter source for TXD. Considering that different X-pinch configurations have characteristic advantages and drawbacks as x-ray generating loads, three distinct copper X-pinch configurations were studied: the wire X-pinch, the hybrid X-pinch, and the laser-cut X-pinch. Furthermore, the Cu K-shell emission from each configuration was characterized and analyzed regarding the specific backlighter requirements for an 8 keV TXD system: spatial and temporal resolution, number of sources, time of emission, spectrum, and reproducibility. Recommendations for future experimental improvements and applications are presented. The electron density of static objects was retrieved from Moiré images obtained through TXD. This allowed to calculate the mass density of static samples within 4% of the expected value for laser-cut X-pinches, which were found to be the optimal X-pinch configuration for TXD due to their high reproducibility, small source size (≤5 µm), short duration (~1 ns), and up to 106 W peak power near 8 keV photon energy. Plasma loads were imaged through TXD for the first-time using laser-cut X-pinch backlighting. Experimental images were compared with simulations from the x-ray wave-front propagation code, demonstrating that TXD can be a powerful x-ray refraction-based diagnostic for dense Z-pinch loads. Future plans for Talbot–Lau interferometry diagnostics in the pulsed-power environment are described.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗