Search NASA⌕ Search

SEARCH · Search NASA

Results for “CONVENTIONAL RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Novel Synthetic Monoketone Transmute Radiation-Triggered NFκB-Dependent TNFα Cross-Signaling Feedback Maintained NFκB and Favors Neuroblastoma Regression

In United States, each year 650 children are diagnosed with neuroblastoma (NB) [1], an embryonal malignancy of sympathetic nervous system that is remarkable for its clinical heterogeneity [2]. Patients with the invasive/metastatic high-risk stage-IV NB showed refraction with all conventional therapeutic modalities and is associated with dismal prognosis [3]. High recurrence rate (20.2%) entailing substantial fractions of both local (17%-74% of patients) [4–8] and distant metastasis (46.8%) present considerable challenges for the clinical management of NB. With only 13 months since first diagnosis to recurrence, the survival ratio was 43% for local and 10% for systemic recurrences. Clinical and laboratory evidence suggests that several human cancers contain populations of rapidly proliferating clonogens that can have substantial impact on local control following chemoradiotherapy [9]. Tumor cell repopulation may arise from remnant cells of the original neoplasm that have escaped therapeutic intervention and later become visible at the original site. Radiotherapy (RT), now widely used for high-risk NB patients after chemotherapy, significantly improved the survival rate [10]. Patients, however, have been confronted with relapse and developed drug/radiation resistance, possibly through favoring alternative pathways. Therapeutic doses of radiation (IR) has been shown to activate various transcription factors including NFκB [11] and studies have suggested their influential role in tumorigenesis and progression [12]. Recently, we demonstrated the radiation triggered NFκB initiates TNFα cross signaling dependent maintenance of NFκB that in turn promotes survival advantage in both in vitro and in vivo NB models [13]. To that end, identifying ‘drug-deliverables’ that selectively disrupt IR-induced NFκB-TNFα feedback signaling and impedes NFκB maintenance could deter NFκB-dependent survival advantage and potentiate RT in NB cure.

59 BASIC BIOLOGICAL SCIENCES↗

Protein crystal structure from non-oriented, single-axis sparse X-ray data

X-ray free-electron lasers (XFELs) have inspired the development of serial femtosecond crystallography (SFX) as a method to solve the structure of proteins. SFX datasets are collected from a sequence of protein microcrystals injected across ultrashort X-ray pulses. The idea behind SFX is that diffraction from the intense, ultrashort X-ray pulses leaves the crystal before the crystal is obliterated by the effects of the X-ray pulse. The success of SFX at XFELs has catalyzed interest in analogous experiments at synchrotron-radiation (SR) sources, where data are collected from many small crystals and the ultrashort pulses are replaced by exposure times that are kept short enough to avoid significant crystal damage. The diffraction signal from each short exposure is so `sparse' in recorded photons that the process of recording the crystal intensity is itself a reconstruction problem. Using the EMC algorithm, a successful reconstruction is demonstrated here in a sparsity regime where there are no Bragg peaks that conventionally would serve to determine the orientation of the crystal in each exposure. In this proof-of-principle experiment, a hen egg-white lysozyme (HEWL) crystal rotating about a single axis was illuminated by an X-ray beam from an X-ray generator to simulate the diffraction patterns of microcrystals from synchrotron radiation. Millions of these sparse frames, typically containing only ~200 photons per frame, were recorded using a fast-framing detector. It is shown that reconstruction of three-dimensional diffraction intensity is possible using the EMC algorithm, even with these extremely sparse frames and without knowledge of the rotation angle. Further, the reconstructed intensity can be phased and refined to solve the protein structure using traditional crystallographic software. In conclusion, this suggests that synchrotron-based serial crystallography of micrometre-sized crystals can be practical with the aid of the EMC algorithm even in cases where the data are sparse.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance of Cloud 3D Solvers in Ice Cloud Shortwave Radiation Closure Over the Equatorial Western Pacific Ocean

Abstract For retrieving cloud optical properties from satellite images or computing these properties from climate model output, computationally efficient treatments of cloud horizontal inhomogeneity include the Monte Carlo Independent Column Approximation (McICA) and the Tripleclouds method. Computationally efficient treatment of cloud horizontal radiation exchanges includes the SPeedy Algorithm for Radiative TrAnsfer through CloUd Sides (SPARTACUS). As a test to derive properties from satellite images, we collocate Moderate Resolution Imaging Spectroradiometer (MODIS) cloud retrievals with near‐nadir Cloud and the Earth's Radiant Energy System (CERES) footprints in July 2008 over an equatorial western Pacific Ocean region to compare the performance of the McICA, Tripleclouds, and SPARTACUS solvers to the conventional plane‐parallel homogeneous (PPH) treatment. PPH overestimates cloud albedo, and the three solvers effectively reduce overestimation with root mean square error of shortwave upwelling irradiance decreasing between 15.72 and 18.53 W m −2 , or about 22%–25%. Although cloud top variability does not get fed into the simulations, all three solvers also reduce the effect of cloud top variability on cloud albedo. Entrapment (energy reflected downward from clouds) and horizontal radiation transfer have opposite effects on the SPARTACUS cloud albedo simulation. The net effect depends on the cloud vertical extent, the unawareness of which limits the performance of the SPARTACUS solver.

54 ENVIRONMENTAL SCIENCES↗

Clinical Pathways: A Catalyst for the Adoption of Hypofractionation for Early-Stage Breast Cancer

Purpose: Hypofractionated whole-breast irradiation (HF-WBI) remains underutilized in the United States despite support by multiple clinical trials. We evaluated the success of iterative modifications of our breast cancer clinical pathway on the adoption of HF-WBI in a large, integrated radiation oncology network. Methods and Materials: The breast clinical pathway was modified in January 2011 (Amendment 1) to recommend HF-WBI as the first option for women ≥70 of age with stages 0 to IIA, while maintaining conventional fractionation (CF) as a pathway-concordant secondary option. In January 2013 (Amendment 2), the pathway's HF-WBI recommendation was extended to women ≥50 years of age. In January 2014 (Amendment 3), the pathway mandated HF-WBI as the only pathway-concordant option in women ≥50 years of age, and all pathway-discordant plans were subject to peer review and justification. Women ≥50 years of age with ductal carcinoma in situ or invasive breast cancer who underwent breast conserving surgery and adjuvant WBI were included in this analysis. Results: We identified 5112 patients from 2009 to 2014 who met inclusion criteria. From 2009 to 2012, the overall HF-WBI use rate was 8.3%. Following Amendments 2 and 3 (2013 and 2014, respectively), HF-WBI use significantly increased to 21.8% (17.3% in the community, 39.7% at academic sites) and 76.7% (75.5% in the community, 81.4% at academic sites), respectively (P<.001). Compared to 2009 to 2012, the relative risk of using HF-WBI was 7.9 (95% confidence interval: 7.1-8.6, P<.001) and 10.7 (95% CI: 10.3-11.0, P<.001), respectively, after Amendments 2 and 3, respectively. Age ≥70 and treatment at an academic site increased the likelihood of receiving HF-WBI in 2009 to 2012 and following Amendment 2 (P<.001). Conclusions: This study demonstrates the transformative effect of a clinical pathway on patterns of care for breast radiation therapy. Although our initial HF-WBI use rate was low (8%-22%) and consistent with national rates, the clinical pathway approach dramatically increased adoption rate to >75%. In contrast to passive guidelines, clinical pathways serve as active tools to promote current best practices.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-Angular-Resolution Microbeam X-Ray Diffraction with CCD Detector

We have introduced a CCD-type two-dimensional X-ray detector for a microbeam X-ray diffraction system using synchrotron radiation, so that we can measure local reciprocal space maps (RSM) of samples rapidly. A local RSM of a strain-relaxed SiGe 004 grown on a Si (001) substrate was measured in higher-angular-resolution and faster than a conventional way. The measurement was achieved in 1 h 40 min. with the 2theta resolution of 80 murad and the spatial resolution of 1.4(h)x0.5(v) {mu}m{sup 2}. The introduction of the CCD enabled us to measure RSMs at many points in a sample, that is, the distribution of strain fields and lattice tilts can be revealed in high-angular- and high-spatial-resolution.

36 MATERIALS SCIENCE↗

Microwave radiation as heating method in the synthesis of titanium dioxide nanoparticles from hexafluorotitanate-organic salts

Nanocrystalline anatase was obtained from ionic liquid-like precursors containing hexafluorotitanate-organic salts and less than 25 wt.% of water, and using boric acid as fluoride scavenger. Two alternative heating methods were explored using either a conventional oven or a domestic microwave apparatus. A significant reduction in the reaction time from 24 h to only few minutes was obtained using the microwave route. The as-prepared materials were characterized by X-ray diffraction, transmission electron microscopy, nitrogen sorption analysis, and attenuated total reflectance Fourier transformed infrared, X-ray photoelectronic and Raman spectroscopes. The convenience of using the microwave heating option was a function of the organic cation present in the precursor. Thus, organic ammonium cations containing only hydrocarbon substituents, such as diethylammonium, phenylammonium and benzyltrimethylammonium led to the precipitation of nanocrystalline anatase powder with high specific surface area (up to 120 m{sup 2} g{sup -1}) in a short processing time (1-3 min). Otherwise, alcohol and carboxylate functionalized cations decomposed under microwave treatment. Moreover, the choice of the organic cation allowed tuning several properties of the end material, such as particle size and pore morphology.

36 MATERIALS SCIENCE↗

Feasibility study of a dual detector configuration concept for simultaneous megavoltage imaging and dose verification in radiotherapy

Purpose: To test the feasibility of a dual detector concept for comprehensive verification of external beam radiotherapy. Specifically, the authors test the hypothesis that a portal imaging device coupled to a 2D dosimeter provides a system capable of simultaneous imaging and dose verification, and that the presence of each device does not significantly detract from the performance of the other. Methods: The dual detector configuration comprised of a standard radiotherapy electronic portal imaging device (EPID) positioned directly on top of an ionization-chamber array (ICA) with 2 cm solid water buildup material (between EPID and ICA) and 5 cm solid backscatter material. The dose response characteristics of the ICA and the imaging performance of the EPID in the dual detector configuration were compared to the performance in their respective reference clinical configurations. The reference clinical configurations were 6 cm solid water buildup material, an ICA, and 5 cm solid water backscatter material as the reference dosimetry configuration, and an EPID with no additional buildup or solid backscatter material as the reference imaging configuration. The dose response of the ICA was evaluated by measuring the detector’s response with respect to off-axis position, field size, and transit object thickness. Clinical dosimetry performance was evaluated by measuring a range of clinical intensity-modulated radiation therapy (IMRT) beams in transit and nontransit geometries. The imaging performance of the EPID was evaluated quantitatively by measuring the contrast-to-noise ratio (CNR) and spatial resolution. Images of an anthropomorphic phantom were also used for qualitative assessment. Results: The measured off-axis and field size response with the ICA in both transit and nontransit geometries for both dual detector configuration and reference dosimetry configuration agreed to within 1%. Transit dose response as a function of object thickness agreed to within 0.5%. All IMRT test patterns and clinical IMRT beams had gamma pass rates of ≥98% at 2%/2 mm criteria. In terms of imaging performance, the measured CNR and spatial resolution (f{sub 50}) were 263.23 ± 24.85 and 0.4025 ± 1.25 × 10{sup −3} for dual detector configuration and 324 ± 26.65 and 0.4141 ± 1.14 × 10{sup −3} for reference imaging configuration, respectively. The CNR and spatial resolution were quantitatively worse in the dual detector configuration due to the additional backscatter. The difference in imaging performance was not visible in qualitative assessment of phantom images. Conclusions: Combining a commercially available ICA dosimetry device with a conventional EPID did not significantly detract from the performance of either device. Further improvements in imaging performance may be achieved with an optimized design. This study demonstrates the feasibility of a dual detector concept for simultaneous imaging and dosimetry in radiation therapy.

60 APPLIED LIFE SCIENCES↗

Is high–dose rate RapidArc-based radiosurgery dosimetrically advantageous for the treatment of intracranial tumors?

In linac-based stereotactic radiosurgery (SRS) and radiotherapy (SRT), circular cone(s) or conformal arc(s) are conventionally used to treat intracranial lesions. However, when the target is in close proximity to critical structures, it is frequently quite challenging to generate a quality plan using these techniques. In this study, we investigated the dosimetric characteristics of using high–dose rate RapidArc (RA) technique for radiosurgical treatment of intracranial lesions. A total of 10 intracranial SRS/SRT cases previously planned using dynamic conformal arc (DCA) or cone-based techniques have been included in this study. For each case, 3 treatment plans were generated: (1) a DCA plan with multiple noncoplanar arcs, (2) a high–dose rate RA plan with arcs oriented the same as DCA (multiple-arc RA), and 3) a high–dose rate RA plan with a single coplanar arc (single-arc RA). All treatment plans were generated under the same prescription and similar critical structure dose limits. Plan quality for different plans was evaluated by comparing various dosimetric parameters such as target coverage, conformity index (CI), homogeneity index (HI), critical structures, and normal brain tissue doses as well as beam delivery time. With similar critical structure sparing, high–dose rate RA plans can achieve much better target coverage, dose conformity, and dose homogeneity than the DCA plans can. Plan quality indices CI and HI, for the DCA, multiple-arc RA, and single-arc RA techniques, were measured as 1.67 ± 0.39, 1.32 ± 0.28, and 1.38 ± 0.30 and 1.24 ± 0.11, 1.10 ± 0.04, and 1.12 ± 0.07, respectively. Normal brain tissue dose (V{sub 12} {sub Gy}) was found to be similar for DCA and multiple-arc RA plans but much larger for the single-arc RA plans. Beam delivery was similar for DCA and multiple-arc RA plans but shorter with single-arc RA plans. Multiple-arc RA SRS/SRT can provide better treatment plans than conventional DCA plans, especially for complex cases.

61 RADIATION PROTECTION AND DOSIMETRY↗

Mechanistic insights into selective oxidation and corrosion of multi-principal element alloys from high resolution and in situ microscopy

Multiple principal elements alloys (MPEAs) have drawn significant recent interest from the metallurgical research community. These novel alloys have the potential to replace traditional alloys with a range of tailored mechanical properties, corrosion resistance, and radiation tolerance enabled by complex compositions. The broad alloy design space of MPEAs presents a great opportunity to discover new forms of oxidation and corrosion resistance in extreme environments that break away from conventional corrosion resistant alloy design criteria. However, understanding the oxidation and corrosion response of MPEAs can be a challenging task due the complex composition, structural, and chemical state changes occurring in the corrosion product and at its interface with the base alloy. This perspective discusses the utility of high resolution and in situ microscopy techniques for revealing unique aspects of MPEA oxidation behavior at the near-atomic level. Challenges of studying these alloys and several open questions are presented.

Kautz, Elizabeth J.↗

Intramolecular Noncovalent Interactions Facilitate Thermally Activated Delayed Fluorescence (TADF)

In the conventional molecular design of thermally activated delayed fluorescence (TADF) organic emitters, simultaneously achieving a fast rate of reverse intersystem crossing (RISC) from the triplet to the singlet manifold and a fast rate of radiative decay is a challenging task. A number of recent experimental data, however, point to TADF emitters with intramolecular π-π interactions as a potential pathway to overcome the issue. Here, we report a comprehensive investigation of TADF emitters with intramolecular π…π or lone-pair…π non-covalent interactions. We uncover the impact of those intramolecular non-covalent interactions on the TADF properties. In particular, we find that folded geometries in TADF molecules can trigger lone-pair…π interactions, introduce a n → π* character of the relevant transitions, enhance the singlet-triplet spin-orbit coupling, and ultimately greatly facilitate the RISC process. Furthermore, this work provides a robust foundation for the molecular design of a novel class of highly efficient TADF emitters in which intramolecular non-covalent interactions play a critical function.

36 MATERIALS SCIENCE↗

A high Q piezoelectric resonator as a portable VLF transmitter

Very low frequency communication systems (3 kHz–30 kHz) enable applications not feasible at higher frequencies. However, the highest radiation efficiency antennas require size at the scale of the wavelength (here, >1 km), making portable transmitters extremely challenging. Facilitating transmitters at the 10 cm scale, we demonstrate an ultra-low loss lithium niobate piezoelectric electric dipole driven at acoustic resonance that radiates with greater than 300x higher efficiency compared to the previous state of the art at a comparable electrical size. A piezoelectric radiating element eliminates the need for large impedance matching networks as it self-resonates at the acoustic wavelength. Temporal modulation of this resonance demonstrates a device bandwidth greater than 83x beyond the conventional Bode-Fano limit, thus increasing the transmitter bitrate while still minimizing losses. These results will open new applications for portable, electrically small antennas.

36 MATERIALS SCIENCE↗

Measurements of accurate x-ray scattering data of protein solutions using small stationary sample cells

In this paper, we report a method of precise in situ x-ray scattering measurements on protein solutions using small stationary sample cells. Although reduction in the radiation damage induced by intense synchrotron radiation sources is indispensable for the correct interpretation of scattering data, there is still a lack of effective methods to overcome radiation-induced aggregation and extract scattering profiles free from chemical or structural damage. It is found that radiation-induced aggregation mainly begins on the surface of the sample cell and grows along the beam path; the diameter of the damaged region is comparable to the x-ray beam size. Radiation-induced aggregation can be effectively avoided by using a two-dimensional scan (2D mode), with an interval as small as 1.5 times the beam size, at low temperature (e.g., 4 deg. C). A radiation sensitive protein, bovine hemoglobin, was used to test the method. A standard deviation of less than 5% in the small angle region was observed from a series of nine spectra recorded in 2D mode, in contrast to the intensity variation seen using the conventional stationary technique, which can exceed 100%. Wide-angle x-ray scattering data were collected at a standard macromolecular diffraction station using the same data collection protocol and showed a good signal/noise ratio (better than the reported data on the same protein using a flow cell). The results indicate that this method is an effective approach for obtaining precise measurements of protein solution scattering.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Inverted orbital polarization in strained correlated oxide films

Manipulating the orbital occupation of valence electrons via epitaxial strain in an effort to induce new functional properties requires considerations of how changes in the local bonding environment affect the band structure at the Fermi level. Using synchrotron radiation to measure the x-ray linear dichroism of epitaxially strained films of the correlated oxide CaFeO 3 , we demonstrate that the orbital polarization of the Fe valence electrons is opposite from conventional understanding. Although the energetic ordering of the Fe 3d orbitals is con rmed by multiplet ligand field theory analysis to be consistent with previously reported strain-induced behavior, we find that the nominally higher energy orbital is more populated than the lower. Here, we ascribe this inverted orbital polarization to an anisotropic bandwidth response to strain in a compound with nearly filled bands. These findings provide an important counterexample to the traditional understanding of strain-induced orbital polarization and reveal a new method to engineer otherwise unachievable orbital occupations in correlated oxides.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Contradicting effective mass scalings in the single-particle spectra calculated using the Skyrme energy density functional method

The problem of the effective mass scaling in the single-particle (s.p.) spectra calculated within the Skyrme energy density functional (EDF) method is studied. It is demonstrated that for specific pairs of orbitals like 1d{sub 3/2}-1f{sub 7/2} the commonly anticipated isoscalar effective mass (m*) scaling of the s.p. level splittings is almost canceled by an implicit m* scaling present in the two-body spin-orbit (SO) strength. On the other hand, the {nu}f{sub 7/2}-{nu}f{sub 5/2} SO splitting depends solely on the SO strength. Hence, two conflicting scaling properties appear to be at work in standard Skyrme EDF, making the theory internally inconsistent with respect to s.p. energies. It is argued that this unphysical property is, to a large extent, a consequence of the strategies and data sets used to fit these functionals. The inclusion of certain s.p. spin-orbit splittings to fit the two-body spin-orbit and the tensor interaction strengths reinstates the conventional m* scaling and improves the performance of the Skyrme EDF.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Initial-state fluctuations in collisions between light and heavy ions

In high-energy collisions involving small nuclei (p + p or x + Au collisions where x = p, d, or 3 He) the fluctuating size, shape, and internal gluonic structure of the nucleon is shown to have a strong effect on the initial size and shape of the fireball of new matter created in the collision. A systematic study of the eccentricity coefficients describing this initial fireball state for several semirealistic models of nucleon substructure and for several practically relevant collision systems involving small nuclei is presented. The key importance of multiplicity fluctuations in such systems is pointed out. Finally, our results show large differences from expectations based on conventional Glauber model simulations of the initial state created in such collisions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Progress toward a hard x-ray insertion device beam position monitor at the Advanced Photon Source.

Long-term pointing stability at synchrotron light sources using conventional rf-based particle beam position monitoring is limited by the mechanical stability of the pickup electrode assembly. Photoemission-based photon beam position monitors for insertion device beams suffer from stray radiation backgrounds and other gap- dependent systematic errors. To achieve the goal of 500-nanoradian peak-to-peak pointing stability over a one-week period, the development of a photon beam position detector sensitive only to hard X-rays (> several keV) using copper X-ray fluorescence has been initiated. Initial results and future plans are presented.

43 PARTICLE ACCELERATORS↗

MO-DE-207A-05: Dictionary Learning Based Reconstruction with Low-Rank Constraint for Low-Dose Spectral CT

Purpose: Spectral CT enabled by an energy-resolved photon-counting detector outperforms conventional CT in terms of material discrimination, contrast resolution, etc. One reconstruction method for spectral CT is to generate a color image from a reconstructed component in each energy channel. However, given the radiation dose, the number of photons in each channel is limited, which will result in strong noise in each channel and affect the final color reconstruction. Here we propose a novel dictionary learning method for spectral CT that combines dictionary-based sparse representation method and the patch based low-rank constraint to simultaneously improve the reconstruction in each channel and to address the inter-channel correlations to further improve the reconstruction. Methods: The proposed method has two important features: (1) guarantee of the patch based sparsity in each energy channel, which is the result of the dictionary based sparse representation constraint; (2) the explicit consideration of the correlations among different energy channels, which is realized by patch-by-patch nuclear norm-based low-rank constraint. For each channel, the dictionary consists of two sub-dictionaries. One is learned from the average of the images in all energy channels, and the other is learned from the average of the images in all energy channels except the current channel. With average operation to reduce noise, these two dictionaries can effectively preserve the structural details and get rid of artifacts caused by noise. Combining them together can express all structural information in current channel. Results: Dictionary learning based methods can obtain better results than FBP and the TV-based method. With low-rank constraint, the image quality can be further improved in the channel with more noise. The final color result by the proposed method has the best visual quality. Conclusion: The proposed method can effectively improve the image quality of low-dose spectral CT. This work is partially supported by the National Natural Science Foundation of China (No. 61302136), and the Natural Science Basic Research Plan in Shaanxi Province of China (No. 2014JQ8317).

60 APPLIED LIFE SCIENCES↗

Doppler-Rabi oscillations of a moving atom due to the roentgen interaction in a cavity

The dynamics of energy exchange between an atom moving in a high-Q cavity and the cavity field is analyzed by taking into account the Roentgen interaction. A two-level atom coupled to a Fock or coherent state of an optical or microwave cavity is considered. The mean cavity photon number required for high-frequency Doppler-Rabi oscillations to occur is relatively high for both Fock-and coherent-state cavity fields and increases with the atomic transition frequency. Conditions are found when the Roentgen interaction plays a key role in the Doppler-Rabi oscillations and must be taken into account, in addition to the conventional electric field-dipole interaction.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗