Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cancer models”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

On the origins of the linear no-threshold (LNT) dogma by means of untruths, artful dodges and blind faith

This paper is an historical assessment of how prominent radiation geneticists in the United States during the 1940s and 1950s successfully worked to build acceptance for the linear no-threshold (LNT) dose–response model in risk assessment, significantly impacting environmental, occupational and medical exposure standards and practices to the present time. Detailed documentation indicates that actions taken in support of this policy revolution were ideologically driven and deliberately and deceptively misleading; that scientific records were artfully misrepresented; and that people and organizations in positions of public trust failed to perform the duties expected of them. Key activities are described and the roles of specific individuals are documented. These actions culminated in a 1956 report by a Genetics Panel of the U.S. National Academy of Sciences (NAS) on Biological Effects of Atomic Radiation (BEAR). In this report the Genetics Panel recommended that a linear dose response model be adopted for the purpose of risk assessment, a recommendation that was rapidly and widely promulgated. The paper argues that current international cancer risk assessment policies are based on fraudulent actions of the U.S. NAS BEAR I Committee, Genetics Panel and on the uncritical, unquestioning and blind-faith acceptance by regulatory agencies and the scientific community. - Highlights: • The 1956 recommendation of the US NAS to use the LNT for risk assessment was adopted worldwide. • This recommendation is based on a falsification of the research record and represents scientific misconduct. • The record misrepresented the magnitude of panelist disagreement of genetic risk from radiation. • These actions enhanced public acceptance of their risk assessment policy recommendations.

54 ENVIRONMENTAL SCIENCES↗

Parametrial Boost Using Midline Shielding Results in an Unpredictable Dose to Tumor and Organs at Risk in Combined External Beam Radiotherapy and Brachytherapy for Locally Advanced Cervical Cancer

Purpose: Midline-blocked boost (MBB) fields are frequently used in the treatment of locally advanced cervical cancer. The purpose of this study was to evaluate the dose contribution from MBBs to tumor and organs at risk. Methods and Materials: Six patients with locally advanced cervical cancer (IIB-IIIB) treated with definitive chemoradiotherapy and magnetic resonance imaging (MRI)-guided brachytherapy were analyzed. A three-phase plan was modeled: 45 Gy (1.8 Gy per fraction) four-field box, 9 Gy (1.8 Gy per fraction) MBB (midline-shielded anteroposterior/posteroanterior fields), and intracavitary MRI-guided brachytherapy boost of 28 Gy (7 Gy per fraction). Midline shields 3, 4, and 5 cm wide were simulated for each patient. Brachytherapy and MBB plans were volumetrically summed. The rectum, sigmoid, and bladder minimum dose in the most exposed 2 cm{sup 3} of an organ at risk (D{sub 2cc}) and high-risk clinical target volume (HR-CTV) and intermediate-risk clinical target volume (IR-CTV) D90 and D100 were evaluated. The intended HR-CTV D90 was 85 Gy or greater, and the intended IR-CTV D90 was greater than 60 Gy. Results: After a 4-cm MBB, HR-CTV D90 remained lower than 85 Gy in all cases (mean, 74 Gy; range, 64-82 Gy). High-risk clinical target volume (85 Gy) coverage increased slightly from 73% (range, 64-82%) to 78% (range, 69-88%). Mean IR-CTV D90 increased from 56 Gy (range, 53-64 Gy) to 62 Gy (range, 59-67 Gy). Intermediate-risk clinical target volume 60-Gy dose coverage increased from 81% (range, 72-96%) to 96% (range, 90-100%). The mean volume irradiated to 85 Gy increased by 14 cm{sup 3} (range, 10-22 cm{sup 3}), whereas the volume irradiated to 60 Gy increased from 276 cm{sup 3} (range, 185-417 cm{sup 3}) to 592 cm{sup 3} (range, 385-807 cm{sup 3}). Bladder, rectum, or sigmoid D{sub 2cc} increased by more than 50% of the boost dose in 4 of 6 patients. Conclusions: Midline-blocked boosts contribute substantial dose to rectum, sigmoid, and bladder D{sub 2cc}. HR-CTV dose and 85-Gy coverage remain compromised in large tumors despite MBB. IR-CTV 60-Gy coverage improved at the expense of a considerable increase in volume of normal tissue irradiated to 60 Gy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Validation of Geant4 fragmentation for Heavy Ion Therapy

12 C ion therapy has had growing interest in recent years for its excellent dose conformity. However at therapeutic energies, which can be as high as 400 MeV/u, carbon ions produce secondary fragments. For an incident 400 MeV/u 12 C ion beam, ~70% of the beam will undergo fragmentation before the Bragg Peak. The dosimetric and radiobiological impact of these fragments must be accurately characterised, as it can result in increasing the risk of secondary cancer for the patient as well as altering the relative biological effectiveness. Here, this work investigates the accuracy of three different nuclear fragmentation models available in the Monte Carlo Toolkit Geant4, the Binary Intranuclear Cascade (BIC), the Quantum Molecular Dynamics (QMD) and the Liege Intranuclear Cascade (INCL++). The models were benchmarked against experimental data for a pristine 400 MeV/u 12 C beam incident upon a water phantom, including fragment yield, angular and energy distribution. For fragment yields the three alternative models agreed between ~5 and ~35% with experimental measurements, the QMD using the “Frag” option gave the best agreement for lighter fragments but had reduced agreement for larger fragments. For angular distributions INCL++ was seen to provide the best agreement among the models for all elements with the exception of Hydrogen, while BIC and QMD was seen to produce broader distributions compared to experiment. BIC and QMD performed similar to one another for kinetic energy distributions while INCL++ suffered from producing lower energy distributions compared to the other models and experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Interleukin-12 and photocarcinogenesis

UV radiation induces immunosuppression and inflammatory responses, as well as oxidative stress and DNA damage, in skin cells and these various effects have been implicated in melanoma and nonmelanoma skin cancers, i.e., photocarcinogenesis. The cytokine interleukin (IL)-12 has been shown to possess potent antitumor activity in a wide variety of murine tumor models. In this review, we summarize the evidence that IL-12 plays a role in preventing photocarcinogenesis, and present a model of its possible mechanisms of action. Treatment of mice with IL-12 prevents UV-induced immunosuppression in a process mediated by repair of UV-induced damaged DNA. After exposure to the photocarcinogenesis protocol, the development of UV-induced tumors is more rapid and the tumor multiplicity and tumor size are significantly greater in IL-12-deficient or knockout (KO) mice than their wild-type counterparts. IL-12-deficiency in mice enhances the proliferation potential of tumor cells, and this may be one of the reasons for the rapid growth of the tumors and their greater size. The rate of malignant transformation of UV-induced papillomas to carcinomas also is higher in the IL-12 KO mice than in their wild-type counterparts in terms of carcinoma incidence and carcinoma multiplicity. UV-induced DNA damage in the form of cyclobutane pyrimidine dimers (CPDs) and sunburn cells is lower, or repaired more rapidly, in wild-type mice than IL-12 KO mice. The IL-12-associated reduction in UV-specific CPDs is due to induction of DNA repair, and particularly enhancement of nucleotide-excision repair. We suggest that endogenous stimulation of IL-12 may protect the skin from UV-induced immunosuppression, DNA damage, and, ultimately, the risk of photocarcinogenesis. Taken together, this information suggests that augmentation of IL-12 should be considered as a strategy for the prevention and treatment of photocarcinogenesis.

60 APPLIED LIFE SCIENCES↗

Comparative toxicity and efficacy of engineered anthrax lethal toxin variants with broad anti-tumor activities

We have previously designed and characterized versions of anthrax lethal toxin that are selectively cytotoxic in the tumor microenvironment and which display broad and potent anti-tumor activities in vivo. Here, we have performed the first direct comparison of the safety and efficacy of three engineered anthrax lethal toxin variants requiring activation by either matrix-metalloproteinases (MMPs), urokinase plasminogen activator (uPA) or co-localized MMP/uPA activities. C57BL/6J mice were challenged with six doses of engineered toxins via intraperitoneal (I.P.) or intravenous (I.V.) dose routes to determine the maximum tolerated dose for six administrations (MTD6) and dose-limiting toxicities. Efficacy was evaluated using the B16-BL6 syngraft model of melanoma; mice bearing established tumors were treated with six I.P. doses of toxin and tumor measurements and immunohistochemistry, paired with terminal blood work, were used to elaborate upon the anti-tumor mechanism and relative efficacy of each variant. We found that MMP-, uPA- and dual MMP/uPA-activated anthrax lethal toxins exhibited the same dose-limiting toxicity; dose-dependent GI toxicity. In terms of efficacy, all three toxins significantly reduced primary B16-BL6 tumor burden, ranging from 32% to 87% reduction, and they also delayed disease progression as evidenced by dose-dependent normalization of blood work values. While target organ toxicity and effective doses were similar amongst the variants, the dual MMP/uPA-activated anthrax lethal toxin exhibited the highest I.P. MTD6 and was 1.5–3-fold better tolerated than the single MMP- and uPA-activated toxins. Overall, we demonstrate that this dual MMP/uPA-activated anthrax lethal toxin can be administered safely and is highly effective in a preclinical model of melanoma. This modified bacterial cytotoxin is thus a promising candidate for further clinical development and evaluation for use in treating human cancers. - Highlights: • Toxicity and anti-tumor activity of protease-activated anthrax toxins were evaluated. • All anthrax toxin variants exhibited potent systemic anti-tumor activity in mice. • A dual MMP/uPA-activated anthrax toxin displayed a superior safety profile. • Clinical development of a dual MMP/uPA-activated anthrax toxin is feasible.

60 APPLIED LIFE SCIENCES↗

Ectopic AP4 expression induces cellular senescence via activation of p53 in long-term confluent retinal pigment epithelial cells

When cells are grown to confluence, cell–cell contact inhibition occurs and drives the cells to enter reversible quiescence rather than senescence. Confluent retinal pigment epithelial (RPE) cells exhibiting contact inhibition was used as a model in this study to examine the role of overexpression of transcription factor AP4, a highly expressed transcription factor in many types of cancer, in these cells during long-term culture. We generated stable inducible RPE cell clones expressing AP4 or AP4 without the DNA binding domain (DN-AP4) and observed that, when cultured for 24 days, RPE cells with a high level of AP4 exhibit a large, flattened morphology and even cease proliferating; these changes were not observed in DN-AP4-expressing cells or non-induced cells. In addition, AP4-expressing cells exhibited senescence-associated β-galactosidase activity and the senescence-associated secretory phenotype. We demonstrated that the induced cellular senescence was mediated by enhanced p53 expression and that AP4 regulates the p53 gene by binding directly to two of the three E-boxes present on the promoter of the p53 gene. Moreover, we showed that serum is essential for AP4 in inducing p53-associated cellular senescence. Collectively, we showed that overexpression of AP4 mediates cellular senescence involving in activation of p53 in long-term post-confluent RPE cells.

60 APPLIED LIFE SCIENCES↗

The E3 ligase for metastasis associated 1 protein, TRIM25, is targeted by microRNA-873 in hepatocellular carcinoma

Highlights: • TRIM25 degrades pro-metastatic protein in hepatocellular carcinoma MTA-1. • TRIM25 expression is downregulated in HCC by miR-873. • Decreasing miR-873 expression can decrease metastasis in xenograft models. • MiR-873 thus can serve as a marker and therapeutic target in HCC patients. Tumor metastasis accounts for 90% of all cancer-related deaths. Epithelial to mesenchymal transition (EMT) considered to be centrally important in acquired resistance to chemotherapy and in progression of tumors to secondary organs. One of the important mediators of metastatic progression in hepatocellular carcinoma (HCC) is the metastasis associated protein 1 (MTA-1). We have earlier shown that in the context of HCC and normal liver cell lines, MTA-1 protein is actively stabilized in HCC cell lines and actively degraded in normal liver cells. We have also shown that TRIM25 is the E3 ligase that interacts with and degrades MTA-1 protein. The identity of the factor regulating expression of TRIM25 in normal liver cells and HCC is unknown. In the current work we elucidate that microRNA (miR)− 873 targets TRIM25 in HCC cells. Both metagenomic analysis and quantification of miR-873 and TRIM25 in 25 HCC patients revealed an inverse correlation between the two in HCC patients with high miR-873 and low TRIM25 expression, respectively. The expression pattern was mimicked in the normal liver cells THLE-2 and the HCC cell line, HuH6. In vitro luciferase reporter assays confirmed TRIM25 as the target of miR-873. Transient transfection of HuH6 cells with an anti-miR-873 antagomir significantly decreased both transwell motility in these cells. Furthermore, in in vivo xenograft assays treatment with anti-miR-873 antagomir significantly decreased hepatic nodules formation. Cumulatively, our data indicate that suppression of TRIM25 expression by high levels of miR-873 dictates MTA1 protein upregulation in HCC.

60 APPLIED LIFE SCIENCES↗

Information Extraction from Cancer Pathology Reports with Graph Convolution Networks for Natural Language Texts

Graph-of-words is a flexible and efficient text representation which addresses well-known challenges, such as word ordering and variation of expressions, to natural language processing. In this paper, we consider the latest graph-based convolutional neural network technique, the Text Graph Convolutional Network (Text GCN), in the context of performing classification tasks on free-form natural language texts. To do this, we designed a study of multi-task information extraction from medical text documents. We implemented multi-task learning in the Text GCN, performed hyperparameter optimization, and measured the clinical task performances. We evaluated micro and macro-F1 scores of four information extraction tasks, including subsite, laterality, behavior, and histological grades from cancer pathology reports. The scores for the Text GCN significantly outperformed our previous studies with convolutional neural networks, suggesting that the Text GCN model is superior to traditional models in task performance.

Yoon, Hong-Jun↗

SU-E-T-191: First Principle Calculation of Quantum Yield in Photodynamic Therapy

Purpose: We present a first-principle method to calculate the spin transfer efficiency in oxygen induced by any photon fields especially in MeV energy range. The optical pumping is mediated through photosensitizers, e.g., porphyrin and/or ensemble of quantum dots. Methods: Under normal conditions, oxygen molecules are in the relatively non-reactive triplet state. In the presence of certain photosensitizer compounds such as porphyrins, electromagnetic radiation of specific wavelengths can excite oxygen to highly reactive singlet state. With selective uptake of photosensitizers by certain malignant cells, photon irradiation of phosensitized tumors can lead to selective killing of cancer cells. This is the basis of photodynamic therapy (PDT). Despite several attempts, PDT has not been clinically successful except in limited superficial cancers. Many parameters such as photon energy, conjugation with quantum dots etc. can be potentially combined with PDT in order to extend the role of PDT in cancer management. The key quantity for this optimization is the spin transfer efficiency in oxygen by any photon field. The first principle calculation model presented here, is an attempt to fill this need. We employ stochastic density matrix description of the quantum jumps and the rate equation methods in quantum optics based on Markov/Poisson processes and calculate time evolution of the population of the optically pumped singlet oxygen. Results: The results demonstrate the feasibility of our model in showing the dependence of the optical yield in generating spin-singlet oxygen on the experimental conditions. The adjustable variables can be tuned to maximize the population of the singlet oxygen hence the efficacy of the photodynamic therapy. Conclusion: The present model can be employed to fit and analyze the experimental data and possibly to assist researchers in optimizing the experimental conditions in photodynamic therapy.

60 APPLIED LIFE SCIENCES↗

Ureter tracking and segmentation in CT urography (CTU) using COMPASS

Purpose: The authors are developing a computerized system for automated segmentation of ureters in CTU, referred to as combined model-guided path-finding analysis and segmentation system (COMPASS). Ureter segmentation is a critical component for computer-aided diagnosis of ureter cancer. Methods: COMPASS consists of three stages: (1) rule-based adaptive thresholding and region growing, (2) path-finding and propagation, and (3) edge profile extraction and feature analysis. With institutional review board approval, 79 CTU scans performed with intravenous (IV) contrast material enhancement were collected retrospectively from 79 patient files. One hundred twenty-four ureters were selected from the 79 CTU volumes. On average, the ureters spanned 283 computed tomography slices (range: 116–399, median: 301). More than half of the ureters contained malignant or benign lesions and some had ureter wall thickening due to malignancy. A starting point for each of the 124 ureters was identified manually to initialize the tracking by COMPASS. In addition, the centerline of each ureter was manually marked and used as reference standard for evaluation of tracking performance. The performance of COMPASS was quantitatively assessed by estimating the percentage of the length that was successfully tracked and segmented for each ureter and by estimating the average distance and the average maximum distance between the computer and the manually tracked centerlines. Results: Of the 124 ureters, 120 (97%) were segmented completely (100%), 121 (98%) were segmented through at least 70%, and 123 (99%) were segmented through at least 50% of its length. In comparison, using our previous method, 85 (69%) ureters were segmented completely (100%), 100 (81%) were segmented through at least 70%, and 107 (86%) were segmented at least 50% of its length. With COMPASS, the average distance between the computer and the manually generated centerlines is 0.54 mm, and the average maximum distance is 2.02 mm. With our previous method, the average distance between the centerlines was 0.80 mm, and the average maximum distance was 3.38 mm. The improvements in the ureteral tracking length and both distance measures were statistically significant (p < 0.0001). Conclusions: COMPASS improved significantly the ureter tracking, including regions across ureter lesions, wall thickening, and the narrowing of the lumen.

60 APPLIED LIFE SCIENCES↗

SU-F-T-240: EPID-Based Quality Assurance for Dosimetric Credentialing

Purpose: We propose a novel dosimetric audit method for clinical trials using EPID measurements at each center and a standardized EPID to dose conversion algorithm. The aim of this work is to investigate the applicability of the EPID method to different linear accelerator, EPID and treatment planning system (TPS) combinations. Methods: Combination of delivery and planning systems were three Varian linacs including one Pinnacle and two Eclipse TPS and, two ELEKTA linacs including one Pinnacle and one Monaco TPS. All Varian linacs had the same EPID structure and similarly for the ELEKTA linacs. Initially, dose response of the EPIDs was investigated by acquiring integrated pixel value (IPV) of the central area of 10 cm2 images versus MUs, 5-400 MU. Then, the EPID to dose conversion was investigated for different system combinations. Square field size images, 2, 3, 4, 6, 10, 15, 20, 25 cm2 acquired by all systems were converted to dose at isocenter of a virtual flat phantom then the dose was compared to the corresponding TPS dose. Results: All EPIDs showed a relatively linear behavior versus MU except at low MUs which showed irregularities probably due to initial inaccuracies of irradiation. Furthermore, for all the EPID models, the model predicted TPS dose with a mean dose difference percentage of 1.3. However the model showed a few inaccuracies for ELEKTA EPID images at field sizes larger than 20 cm2. Conclusion: The EPIDs demonstrated similar behavior versus MU and the model was relatively accurate for all the systems. Therefore, the model could be employed as a global dosimetric method to audit clinical trials. Funding has been provided from Department of Radiation Oncology, TROG Cancer Research and the University of Newcastle. Narges Miri is a recipient of a University of Newcastle postgraduate scholarship.

43 PARTICLE ACCELERATORS↗

components for the MuMMI software release

The Department of Energy and the National Cancer Institute have developed new software for conducting multi-scale simulations of complex systems. This software, called the Multiscale Machine-Learned Modeling Infrastructure (MuMMI), couples simulations on three spatial scales to study slow, large-scale reorganizations of biomolecular systems with the speed of continuum and coarse-grained models while revealing selected interactions at full atomic precision. In these simulations, coarse-to-fine model conversions are used to spawn relevant fine-scale simulations along chosen order parameters, and fine-to-coarse feedback is used to iteratively improve the accuracy and multi-scale consistency of coarse-scale and continuum simulations. The complete MuMMI framework will be reviewed and released as open-source software by Lawrence Livermore National Laboratory. This review covers a subset of the MuMMI components that were developed exclusively at the Los Alamos National Laboratory.

Neale, Christopher↗

COX-2/sEH Dual Inhibitor PTUPB Potentiates the Antitumor Efficacy of Cisplatin

Cisplatin-based therapy is highly toxic, but moderately effective in most cancers. Concurrent inhibition of cyclooxygenase-2 (COX-2) and soluble epoxide hydrolase (sEH) results in antitumor activity and has organ-protective effects. The goal of this paper was to determine the antitumor activity of PTUPB, an orally bioavailable COX-2/sEH dual inhibitor, in combination with cisplatin and gemcitabine (GC) therapy. NSG mice bearing bladder cancer patient-derived xenografts were treated with vehicle, PTUPB, cisplatin, GC, or combinations thereof. Mouse experiments were performed with two different PDX models. PTUPB potentiated cisplatin and GC therapy, resulting in significantly reduced tumor growth and prolonged survival. PTUPB plus cisplatin was no more toxic than cisplatin single-agent treatment as assessed by body weight, histochemical staining of major organs, blood counts, and chemistry. The combination of PTUPB and cisplatin increased apoptosis and decreased phosphorylation in the MAPK/ERK and PI3K/AKT/mTOR pathways compared with controls. PTUPB treatment did not alter platinum–DNA adduct levels, which is the most critical step in platinum-induced cell death. The in vitro study using the combination index method showed modest synergy between PTUPB and platinum agents only in 5637 cell line among several cell lines examined. However, PTUPB is very active in vivo by inhibiting angiogenesis. Finally, PTUPB potentiated the antitumor activity of cisplatin-based treatment without increasing toxicity in vivo and has potential for further development as a combination chemotherapy partner.

60 APPLIED LIFE SCIENCES↗

Somatic Mutation Analysis in Spaceflight: NASA Twins Genome Study

The NASA Twins Genome Study investigates the effects of spaceflight on somatic mutation accumulation by comparing genome-wide sequence data from a spaceflight astronaut and his Earth-bound twin. Utilizing advanced computational software on high performance computers, this study identifies and maps somatic mutations, with implications for understanding spaceflight-associated health risks, including cancer, neurodegeneration, and cardiovascular disease. The findings aim to bridge rodent and human space research, offering insights into tissue-specific pathophysiology, risk models, and potential therapeutic interventions.

somatic mutation↗

TH-AB-209-12: Tissue Equivalent Phantom with Excised Human Tissue for Assessing Clinical Capabilities of Coherent Scatter Imaging Applications

Purpose: Previously we reported the development of anthropomorphic tissue-equivalent scatter phantoms of the human breast. Here we present the first results from the scatter imaging of the tissue equivalent breast phantoms for breast cancer diagnosis. Methods: A breast phantom was designed to assess the capability of coded aperture coherent x-ray scatter imaging to classify different types of breast tissue (adipose, fibroglandular, tumor). The phantom geometry was obtained from a prone breast geometry scanned on a dedicated breast CT system. The phantom was 3D printed using the segmented DICOM breast CT data. The 3D breast phantom was filled with lard (as a surrogate for adipose tissue) and scanned in different geometries alongside excised human breast tissues (obtained from lumpectomy and mastectomy procedures). The raw data were reconstructed using a model-based reconstruction algorithm and yielded the location and form factor (i.e., momentum transfer (q) spectrum) of the materials that were imaged. The measured material form factors were then compared to the ground truth measurements acquired by x-ray diffraction (XRD) imaging. Results: Our scatter imaging system was able to define the location and composition of the various materials and tissues within the phantom. Cancerous breast tissue was detected and classified through automated spectral matching and an 86% correlation threshold. The total scan time for the sample was approximately 10 minutes and approaches workflow times for clinical use in intra-operative or other diagnostic tasks. Conclusion: This work demonstrates the first results from an anthropomorphic tissue equivalent scatter phantom to characterize a coherent scatter imaging system. The functionality of the system shows promise in applications such as intra-operative margin detection or virtual biopsy in the diagnosis of breast cancer. Future work includes using additional patient-derived tissues (e.g., human fat), and modeling additional organs (e.g., lung).

60 APPLIED LIFE SCIENCES↗

Descriptive Analysis of Oligometastatic Lesions Treated With Curative-Intent Stereotactic Body Radiotherapy

Purpose: To characterize oligometastases in patients enrolled on two prospective pilot studies, treating oligometastases with hypofractionated stereotactic body radiotherapy and stereotactic radiosurgery to cranial lesions. Methods and Materials: We describe the characteristics and local control (LC) of 293 lesions in 121 patients with five or fewer metastases treated with stereotactic body radiation and/or cranial stereotactic radiosurgery. For each lesion, the primary cancer site, tumor histology, site of metastasis, gross tumor volume, and prescribed dose were ascertained. The prescribed dose is expressed by the biologically effective dose in 2-Gy fractions (BED2), calculated using the linear quadratic model, assuming an {alpha}/{beta} ratio of 10. Results: Lung lesions were significantly smaller than other lesions in our cohort, whereas liver lesions were significantly larger, possibly reflecting a detection and/or referral bias. The 2-year and 4-year tumor LC rates were 77% and 73% respectively. A larger gross tumor volume was significantly (p < 0.0001) correlated with worse lesion LC. Lesions originating from primary pancreatic, biliary or liver cancer exhibited significantly poorer LC, as did lesions from colorectal cancer. Lesions from breast cancer were better controlled. A higher BED2 did not correlate with improved tumor control. Conclusions: Stereotactic body radiation to aggressively treat oligometastatic lesions results in good local tumor control. Bulkier lesions are more difficult to control and may benefit from dose escalation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Theoretical Benefits of Dynamic Collimation in Pencil Beam Scanning Proton Therapy for Brain Tumors: Dosimetric and Radiobiological Metrics

Purpose: To quantify the dosimetric benefit of using a dynamic collimation system (DCS) for penumbra reduction during the treatment of brain tumors by pencil beam scanning proton therapy (PBS PT). Methods and Materials: Collimated and uncollimated brain treatment plans were created for 5 patients previously treated with PBS PT and retrospectively enrolled in an institutional review board–approved study. The in-house treatment planning system, RDX, was used to generate the plans because it is capable of modeling both collimated and uncollimated beamlets. The clinically delivered plans were reproduced with uncollimated plans in terms of target coverage and organ at risk (OAR) sparing to ensure a clinically relevant starting point, and collimated plans were generated to improve the OAR sparing while maintaining target coverage. Physical and biological comparison metrics, such as dose distribution conformity, mean and maximum doses, normal tissue complication probability, and risk of secondary brain cancer, were used to evaluate the plans. Results: The DCS systematically improved the dose distribution conformity while preserving the target coverage. The average reduction of the mean dose to the 10-mm ring surrounding the target and the healthy brain were 13.7% (95% confidence interval [CI] 11.6%-15.7%; P<.0001) and 25.1% (95% CI 16.8%-33.4%; P<.001), respectively. This yielded an average reduction of 24.8% (95% CI 0.8%-48.8%; P<.05) for the brain necrosis normal tissue complication probability using the Flickinger model, and 25.1% (95% CI 16.8%-33.4%; P<.001) for the risk of secondary brain cancer. A general improvement of the OAR sparing was also observed. Conclusion: The lateral penumbra reduction afforded by the DCS increases the normal tissue sparing capabilities of PBS PT for brain cancer treatment while preserving target coverage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Synergistic Effect of Simvastatin Plus Radiation in Gastric Cancer and Colorectal Cancer: Implications of BIRC5 and Connective Tissue Growth Factor

Purpose: We investigated the synergistic effect of simvastatin, a 3-hydroxy-3-methylglutaryl coenzyme A reductase inhibitor plus radiation therapy, on the proliferation and survival of gastric cancer (GC) and colorectal cancer (CRC) cells. We also studied several genes involved in the simvastatin/radiation-induced effects. Methods and Materials: Gastric cancer (AGS, SNU601, MKN1, and MKN28) and CRC (CoLo320, SW48, HT29, and HCT8) cell lines were treated with 0.2 μM simvastatin alone, or in combination with 0 to 4 Gy of radiation, and subjected to clonogenic survival and proliferation assays in vitro. To assess the molecular mechanism of the combination treatment, we performed microarray analysis, immunoblot assays, small interfering RNA knockdown experiments, and plasmid rescue assays. The antitumoral effects of simvastatin and radiation were evaluated in vivo using xenograft models. Results: The combination therapy of simvastatin plus radiation inhibited basal clonogenic survival and proliferation of GC and CRC cells in vitro. Simvastatin suppressed the expression of BIRC5 and CTGF genes in these cancer cells. In vivo, the combined treatment with simvastatin and radiation significantly reduced the growth of xenograft tumors compared with treatment with radiation alone. Conclusion: We suggest that simvastatin has a synergistic effect with radiation on GC and CRC through the induction of apoptosis, which may be mediated by a simultaneous inhibition of BIRC5 and CTGF expression. A clinical trial of simvastatin in combination with radiation in patients with GC or CRC is warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗