Search NASA⌕ Search

SEARCH · Search NASA

Results for “Capacitance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Capacitor discharge pulse analysis.

Capacitors used in firing sets and other high discharge current applications are discharge tested to verify performance of the capacitor against the application requirements. Parameters such as capacitance, inductance, rise time, pulse width, peak current and current reversal must be verified to ensure that the capacitor will meet the application needs. This report summarizes an analysis performed on the discharge current data to extract these parameters by fitting a second-order system model to the discharge data and using this fit to determine the resulting performance metrics. Details of the theory and implementation are presented. Using the best-fit second-order system model to extract these metrics results in less sensitivity to noise in the measured data and allows for direct extraction of the total series resistance, inductance, and capacitance.

Baker, Michael Sean↗

The Design Fabrication Installation & Evaluation of the Balance Probe Monitor for Large Centrifuges at a National Laboratory Facility.

Balance Probe Monitors were designed, fabricated, installed, and evaluated at Sandia National Laboratories (SNL) for the 22,600 g kg (50,000 g lb) direct drive electromotor driven large centrifuges. These centrifuges provide a high onset/decay rate g environment. The Balance Probe Monitor is physically located near a centrifuge’s Capacitance Probe, a crucial sensor for the centrifuge’s sustainability. The Balance Probe Monitor will validate operability of the centrifuge. Most importantly, it is used for triggering a kill switch under the condition that the centrifuge displacement value exceeds allowed tolerances. During operational conditions, the Capacitance Probe continuously detects the structural displacement of the centrifuge and an adjoining AccuMeasure 9000 translates this displacement into an output voltage.

47 OTHER INSTRUMENTATION↗

Ultra-Low Noise Germanium Neutrino Detection system (ULGeN).

Monitoring nuclear power plant operation by measuring the antineutrino flux has become an active research field for safeguards and non-proliferation. We describe various efforts to demonstrate the feasibility of reactor monitoring based on the detection of the Coherent Neutrino Nucleus Scattering (CNNS) process with High Purity Germanium (HPGe) technology. CNNS detection for reactor antineutrino energies requires lowering the electronic noise in low-capacitance kg-scale HPGe detectors below 100 eV as well as stringent reduction in other particle backgrounds. Existing state- of-the-art detectors are limited to an electronic noise of 95 eV-FWHM. In this work, we employed an ultra-low capacitance point-contact detector with a commercial integrated circuit preamplifier- on-a-chip in an ultra-low vibration mechanically cooled cryostat to achieve an electronic noise of 39 eV-FWHM at 43 K. We also present the results of a background measurement campaign at the Spallation Neutron Source to select the area with sufficient low background to allow a successful first-time measurement of the CNNS process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SULI Final Report

This project looks at alternative water sources, specifically in the field of desalination and selective ion removal through capacitive deionization (CDI). It project aims to both scale up the desalination capabilities of CDI cells as well as determine the selectivity of CDI for particular ions. My task is to design and build cells that have reproducible performance and characterize the materials for building these cells. The scientific methods I’ve learned through my work in CDI and the data mining and analysis tools I’ve become familiar with through CAES will be important catalysts in my future success in a graduate program. The purpose of this presentation is to give a standard of practice for my current method of building of capacitive deionization cells. Parts 1 and 2 will be discussed in which the electrodes are prepared, and the cell is built.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Zeptocalorimetry

Here we present the development of a Zeptocalorimeter. The motivation for designing and implementing such a device is driven, ultimately, by its anticipated exceptional sensitivity (10-21 J/K, at 2K). Such a device would be highly valuable in detecting minute quantities of mass for threat detection, studying fundamental phonon physics, and detecting energetic dissipation events at the attojoule level. To date, the most sensitive calorimeter demonstrated in the literature at 2K has been developed by the Roukes group at Caltech, where they achieved an addendum heat capacity of 10 -15 J/K with a 1/1000 sensitivity to external stimuli. To obtain such a low value of heat capacity requires a very small thermal mass, and thus, one of the greatest challenges in this project is the fabrication of this device, which requires numerous precision nanofabrication techniques. Furthermore, the heat capacity measurement of this device, as performed from room temperature to cryogenic temperatures, is equally challenging, as the transient signals used to determine the platform's thermal time constant require careful attention to the mitigation of feedthrough capacitance and delicate amplifier offsets. In this report we describe in detail the fabrication process flow for developing the calorimeter, including the layout and device design for obtaining a single lumped RC thermal resistance and capacitance, so that the device can be used for quantitative measurements of nanoscale materials with a suitable thermal link. The measurement method and experimental setup are also given, where we explain the heater and thermometer calibration methods, the thermal resistance measurements, the transient measurements, and lastly the cryogenic setup with intermediate frequency cabling and the thermal sinking of those lines.

47 OTHER INSTRUMENTATION↗

Crosscutting Recombination Metrology for Expediting VOC Engineering

Work carried out under this grant addressed the need for improved materials and device characterization of solar cell designs. This experimental program aimed to develop joint electrical and optical studies of solar cells based on the group-II-VI semiconductor CdTe and the chalcogenide semiconductor Cu(InGa)Se 2 . Electrical measurements focused on temperature (T) and illumination intensity (I) dependence of the open-circuit voltage (VOC), a quantity that plays an important role in conversion efficiency. The VOC depends on temperature and illumination intensity through the energy gap and positions of the quasiFermi levels (QFLs). Optical measurements exploited the illumination and temperature dependence of absolute photoluminescence (PL) intensity (PL-I), a quantity that also depends on the QFL positions. The QFL splitting is a quantity that also depends on recombination rates within the solar cell, including radiative and non-radiative processes. Other factors affect the electrical and optical properties. These include band offsets at both the front and back interfaces of the device active region where electrical contacts are formed. Understanding, locating, and quantifying the recombination properties of the solar cells was the principal goal of this research. Custom simulations were developed to solve continuity and Poisson equations selfconsistently to obtain free-electron and free-hole concentrations. The measurements of temperature and intensity dependent VOC and PL-I allowed the extraction of a number of physical parameters including the conduction band offset, the shunt constant, and the effective capture coefficient for recombination centers, both within the absorber and at the absorber-buffer interface. In addition, the back-contact barrier height is determined from electrical properties. Each of these is discussed in the report. The illumination intensity dependence of VOC and PL-I do not overlap in experiments primarily because PL is not observed in the low-intensity regime where VOC is studied. Absolute PL-I measurements enabled development of an approach directly comparing it with VOC. This in turn allowed development of a simulation capability that would consistently use both measurements, as functions of T and I, for producing a minimization scheme using a differential evolution algorithm. The approach was applied to both CdTe and Cu(InGa)Se 2 solar cells each prepared under various conditions. Shunt conductivity, QFL splitting, recombination were measured. Also extensively studied are current-voltage and frequency-dependent capacitance voltage. Work completed under this grant included studies of magnesium zinc oxide (MZO) buffered CdTe solar cells including the effects of hydroiodic acid (HI) treatment. From these studies the recombination rates were quantified at the buffer/absorber (front) interface. The effect of back-contact barrier height was investigated. CdTe solar cells were prepared with CdSe and CdS buffer layers. Lower grain-boundary potential fluctuation, higher back-contact barrier height, and greater bulk recombination were observed in early devices with CdSe buffer layer. Investigations were also carried out into CdS/Cu(InGa)Se 2 solar cells. A metal-insulatorsemiconductor capacitance-voltage technique was developed to extract recombinationrelevant properties of the absorber interface. From this work the density of interface states D it , their capture cross-section σ, fixed charge at the interface Q f , and surface recombination velocity were all extracted.

14 SOLAR ENERGY↗

LANL studies of ESD spark energy discharge through September 2019

Two concentric-sphere apparatuses were used to measure the energies deposited by electric sparks through air to calibrated loads. Both sets of spheres had clean, uninsulated metal surfaces. The 127-mm diameter pair of spheres had a gap of 10 mm and a capacitance of 52 pF. The maximum energy stored on these spheres was 12 mJ and the maximum energy delivered to the 50-mΩ load was 11 µJ, with or without inductance. This load energy amounted to 0.09% of the available input energy; the remainder of the input energy was expended in forming the spark. The second set of spheres was 330 mm in diameter with a gap of 14 mm and a capacitance of 240 pF. The maximum energy stored on these spheres was 71 mJ and the maximum energy delivered to the 50-mΩ load was 150 µJ without added inductance. This load energy was 0.27% of the input energy; again, the remainder of the input energy was expended in forming the spark. The inclusion of 250 nH and 500 nH inductances in the discharge path of the smaller spheres caused the current discharges to resonate, but had little effect on the maximum energies deposited in the loads. At the time of writing, inductances had not yet been added to the larger spheres. The magnitudes of the observed spark discharges were stochastic, so more than 1200 tests were required to develop the statistical bounds of the spark behavior, i.e., to estimate the worst case (highest likely) energy depositions in the loads. The action integrals of the current discharges $∫ i^2dt$ were found to be approximately independent of the load resistances for loads of less than ~1 Ω. Hence the energy deposition scaled with resistance as 207 µJ/Ω and 2.93 mJ/Ω for the two apparatuses.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

PSL-AC-CP-1102-004-03: Electrostatic Discharge Simulator Kit Model 930D and Associated Current-Viewing Resistor (V.04)

This document provides instructions for calibrating the Electro-Tech (ETS) electrostatic discharge (ESD) simulator, Model 930D. The calibration shall meet the ± 5% specification for resistance and capacitance as specified in MIL-STD-331C 2009 newer. A series of direct measurements of the Device Under Test (DUT) output at 25 kV using a calibrated LeCroy HDO 6104 oscilloscope (or equivalent 1 MΩ) input impedance storage oscilloscope) are recorded through the 500-pF capacitor, 500-Ω resistor, and a 1-Ω Current Viewing Resistor (CVR). The certified value of the DUT's 25 kV output is calculated using Ohms Law and the certified system resistance and capacitance described in this procedure. Read this document in its entirety before proceeding with the calibration.

42 ENGINEERING↗

Plasma Guns for Magnetized Fuel Targets for PJMIF

In plasma jet driven magneto-inertial fusion (PJMIF) an array of discrete supersonic plasma jets is used to form a spherically imploding plasma liner, which then compresses a magnetized plasma target to fusion conditions. With funding from ARPA-E’s ALPHA program and from Strong Atomics LLC, HyperJet Fusion Corp and HyperV Technologies Corp. previously developed the plasma guns required for an experimental demonstration of the plasma liner formation part of the concept. A 36-gun demonstration of an imploding spherical plasma liner is currently underway on the PLX facility at Los Alamos National Laboratory. This present project addresses the next step required for a complete PJMIF concept, i.e. developing the magnetized plasma target. We proposed to form the target by stagnating a number of magnetized plasma jets in the center of the target chamber. This is accomplished by adding a bias field coil to the plasma liner gun to form a magnetized plasma jet. This experimental development took place at HyperJet in a geometry replicating the bias field environment that will be seen on a PLX port so the results are directly transferrable to the PLX experiment. The objective of this effort was the technical development and characterization of a new magnetized plasma jet using a high-performance, high momentum flux, contoured-gap coaxial plasma gun appropriate for use on the next stage of the PLX experiment. Electromagnetic modeling of the coil indicated the coil was best placed around the aluminum tubes of the gun transmission line, rather than around the chamber port as originally proposed. This maximized field strength in the breech and yielded much better flux linkage between gun electrodes. A 30-turn coil was ultimately implemented, allowing long pulses that could diffuse through the metal walls on the timescale of interest. \machtwo modeling predicted that less capacitance in the main PFN could potentially improve plasma jet velocities due to better matching of the current to the smaller plasma mass and the existing electrode contour designed to suppress blowby. This proved true, as testing showed markedly improved performance when the original 600uF bank was reduced to 400uF. A number of diagnostics were built and/or upgraded in order to characterize the plasma jets, inluding laser interferomtery for density, photodiodes for velocity, Bdot probes for magnetic field measurements, a Triple probe for temperature measurements, and spectroscopy for impurity content. A plasma gun with the 30-turn magnet coil installed, a 70% reduction in gas valve plenum volume, and a 33% reduction in main PFN capacitance produced a dense, high velocity, well magnetized plasma jet. We met or exceeded virtually all of the plasma jet parameter goals. Peak velocity of 135 km/s exceeded the 100 km/s goal by 35%, while the peak density of over 1.0x10 15 cm -3 was 3.3 times the goal of >3.0x10 14 cm -3 . Shot-to-shot repeatability is excellent, with a jitter of less than 300ns observed on the arrival fronts of the photodiode signals from one shot to the next. Average plasma jet lengths of 33cm (at 120km/s) were slightly longer than the 20cm goal, but jets as short as 11.8cm were observed at 135km/s. Mass is much higher than the targeted goal, averaging 106ug per shot compared to 20ug. The magnetic field is still a bit lower than desired, with a maximum to date of ~811G, compared to the goal of 1000G. Average values, though, were typically in the 300-450G range, when measured further downstream after some expected in flight decay. Temperature measurements are still a work in progress. Increasing the B field and completing temperature measurements will be continued on into the ongoing BETHE project.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

K-Modules

K-Modules are capacitive energy modules designed to be stacked together to form a capacitor bank (aka a Marx bank). Discharging the stack produces a single, high voltage, high current pulse that when coupled to an X-ray (or electron) tube, produces energetic X-rays (or an intense electron beam, E-beam). The energetic X-rays are used in Flash X-ray Radiography (FXR), a technique to image objects moving at extremely high speed to measure their speed, shape and internal density profiles. The images help validate computer models for materials behavior under extreme pressure and temperature. FXR is a technology critical to dynamic experiments for the national security mission, and most users are DOE and DOD labs. Febetrons, the X-ray generating devices, are used at these sites and rely on capacitive energy modules for their operation. A stack of the newly developed K-modules will significantly extend the capabilities of these Febetrons

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Integrators

Many electromagnetic measurements detect signals that are the time derivative of the actual quantity of interest. Examples include so-called “B-dot” and “D-dot” detectors that are used for measuring transient magnetic and electric fields. Integration of these signals to recover the quantity of interest is performed either by hardware integrators in the signal line, or by software coding in the analysis programming. Hardware integration is usually done using a classic resistive-capacitive (RC) circuit, or internally in the detector by induction (L/R) or stray capacitance (RC). These hardware integration methods are only approximate, and must be corrected for distortion. This is usually called “droop correction.” In this note, we will examine this correction in some detail. Transient analysis via Laplace transforms will be used to simplify the mathematics. A rudimentary understanding of this method is assumed.

42 ENGINEERING↗

HPE ultralit project (ARPA-E open program 2018) final report 15

The goal of the program was to build a fully integrated optical transceiver with >1 Tb/s and <1.5 pJ/bit operating at 50 ◦ C. Optical transceivers are critical components in high-performance-computers (HPC) and data centers, and the details of their implementation has a big impact on the total power consumption (energy efficiency) of an HPC system. Our proposed transceiver used three key enabling technologies. Firstly, SiGe avalanche photodetectors have record-low sensitivities, meaning that they can reach low bit error rates with very little light input. As a result, we can drive our lasers at a lower drive current, thus saving electrical power. Secondly, we use MOS-based capacitive tuning in our deinterleaver, modulator, and demultiplexer. Capacitive tuning allows for the tuning of photonic elements with zero static power consumption. Thirdly, we use quantum dots as the gain material in our light source. This allows us to efficiently use our light source at temperatures that are typically encountered in an HPCsystem. Our proposed optical transceiver consisted of a quantum dot comb laser as a light source, a booster SOA, MOS-based deinterleavers, MOS based ring modulators, MOS-based ring demultiplexers, and SiGe APDs.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

An ALEGRA MHD Spark Model

While modeling a generic pulse transformer, we became interested in the possibility of electric sparks between winding layers in a solid encapsulant. We significantly modified a previously developed ALEGRA MHD model of a generic spark in lexan. The cumulative modifications are significant enough to report here. Possibly the most significant modification was a change in how the simulated spark is initiated from a thin initial channel. The change was from imposing an initial hot temperature to imposing a conductivity floor. The reasons and comparisons of results are included. The second significant change was to replace a fixed current rise rate with an external circuit model. We built a model specifically mimicking the distributed inductance and stray capacitance between the coil turns closest to the modeled spark. Excursions from nominal values examine the sensitivity of resulting behaviors to extreme capacitance and inductance values.

42 ENGINEERING↗

Upcycling Polyethylene Waste to Advanced Carbon Materials for Energy Storage Applications

Polyethylene is notoriously difficult to upcycle because it decomposes into light gases at approximately 350-400 °C which prevents processing it at higher temperatures to convert it into high-value carbon materials, such as graphene or graphite. We address this challenge by using an air-based, thermo-oxidation process, which heats polyethylene (PE) just below the decomposition point to initiate oxidation and cross-linking of PE alkyl chains. These molecular transformations allow PE to be further graphenized or graphitized at higher temperatures without decomposing. The PE-derived graphene has a specific surface area up to 1,800 m 2/g and Raman ID/IG ratio of 0.85, which enables it to be used as an electrode material for a symmetric supercapacitor with the 1 M H2SO4 electrolyte. The PE-derived graphene material has a comparable electrochemical capacitive performance, such as power density, specific capacitance, and long cycle stability, to the commercial state of art porous carbon electrode. The stabilized PE could also be converted into highly crystalline flake graphite via low-temperature catalytic graphitization. The PE-derived graphite is used for the lithium-ion battery anode, which showed comparable electrochemical battery performance, such as reversible rate performance and long-term cyclic stability, to the current use battery-grade graphite, thus providing a scalable method to upcycle PE plastic waste into high-value carbon material.

Gao, Yuan↗

Interpreting T-History Data on Supercooling and Phase Change Enthalpy of a Salt-Hydrogel Complex for Building Thermal Management

Phase change materials (PCMs) are promising materials for storing and discharging latent heat in buildings to regulate the thermal environment. Measurement of salt hydrate PCM thermal performance is often challenging because of supercooling and phase segregation. Though differential scanning calorimetry (DSC) has been widely used to measure thermal properties of various phase change materials, DSC uses milligrams of sample and is unrealistic for predicting large-scale materials performance. The T-history method [1], in contrast, handles higher volumes but the analysis typically requires a lumped capacitance assumption. Here, we report and analyze T-History data on a novel salt-hydrogel complex with high viscosity, that renders low Biot number sample preparation extremely challenging. We re-examine the standard T-history method and compared against DSC data in this complex material. We report details of an experimental setup, built with necessary additions to a controlled environmental chamber. We carefully examine the validity of the lumped capacitance assumption and suggest a modified analysis using a computational approach for reliable data. Experimental parameters such as ramp rate and temperature range of the environmental chamber are considered via computational modeling to understand the effect of ramp rate on supercooling [2]. Finally, we report thermal cycling experiments on the salt-hydrogel complex. Our modified approach to measuring supercooling and enthalpy of fusion at large scales is important in better understanding the performance of phase-change materials at scale for building thermal storage. References: [1] Marin, Jose M, Belen Zalba, Luisa F Cabeza, and Harald Mehling. “Determination of Enthalpy Temperature Curves of Phase Change Materials with the Temperature-History Method: Improvement to Temperature Dependent Properties.” Measurement Science and Technology 14, no. 2 (February 1, 2003): 184–89. https://doi.org/10.1088/0957-0233/14/2/305. [2] Safari, A., R. Saidur, F.A. Sulaiman, Yan Xu, and Joe Dong. “A Review on Supercooling of Phase Change Materials in Thermal Energy Storage Systems.” Renewable and Sustainable Energy Reviews 70 (April 2017): 905–19. https://doi.org/10.1016/j.rser.2016.11.272

thermodynamics↗

Dielectric Spectroscopy Cable NDE for Unequal Aging Over Different Lengths

This Pacific Northwest National Laboratory milestone report assesses the effect of unequal aging over different lengths of cable on dielectric spectroscopy (DS) bulk impedance measurements from the cable end. DS measurements can indicate the remaining useful life of cables; however, most benchmark tests are based on accelerated aging of the entire cable. If only a portion of the cable is exposed to a harsh environment (as is frequently the case), the DS measurement will indicate a significantly less-aged cable than if the entire cable were exposed to a uniform environmental stress. The DS measurement is primarily related to the intrinsic insulation material relative permittivity—typically between 1.5 and 3.0. Insulation aging increases permittivity and, correspondingly, the cable’s overall capacitance measured from the cable end. To judge the health of the overall cable system, operators are primarily interested in the condition of the most severely aged section since that is where a failure is most likely to occur. This can be expressed as the dimensionless relative permittivity of the severely aged section divided by the permittivity of a pristine cable. This relative permittivity is an intrinsic material parameter independent of cable length and can serve as a quantitative indication of the insulation condition. If the relative percentages of cable exposed to a harsh and benign environment are known, the DS measurement of the entire cable length, including both pristine and aged sections, can be compensated to predict the relative permittivity (relative to pristine permittivity) of the most severly aged segment. A test was performed on three 50 ft (16 m) cables with 10%, 50%, and 90% of the cable inside a thermal aging oven. Predictably, the aging effect on the DS response was greatest in the 90% sample, followed by the 50% sample, and then the 10% sample. The more interesting result is the ratio of the aged insulation permittivity to the pristine insulation permittivity. Based on prior work, an end-of-life cable has a value of approximately 1.35. If the relative percentages of pristine and severely aged cable lengths are known, and the total cable-length capacitance of the initial pristine cable and the combined pristine plus aged cable are known, the relative aged permittivity (ratio of aged section permittivity / pristine section permittivity) can be estimated. The relative cable lengths exposed to a harsh environment may be known or estimated based on plant layout drawings or cable reflectometry tests that can locate the oven entry and exit points. The compensation was verified using a lumped-parameter model to predict the aged-segment permittivity e2/e1, where e2 is the aged-segment permittivity and e1 is the pristine-segment permittivity. For all three percentages of aged cable lengths, the ratio was quite similar, as would be expected since all cable segments were exposed to the same aging environment. This ratio of aged permittivity to pristine permittivity can be compared to other damage indicating tests, including elongation at break, to assess cable condition.

ARENA Test Bed↗

Anion Coordination Improves High-Temperature Performance and Stability of NaPF 6 -Based Electrolytes for Supercapacitors

Electrolyte stability can be improved by incorporating complexing agents that bind key decomposition intermediates and slow down decomposition. We show that hexamethyl-phosphoramide (HMPA) extends both the thermal stability threshold of sodium hexafluorophosphate (NaPF 6 ) in dimethoxyethane (DME) electrolyte and the cycle life of double-layer capacitors. HMPA forms a stable complex with PF 5 , an intermediate in PF 6 anion thermal degradation. Unbound, this intermediate leads to autocatalytic degradation of the electrolyte solution. The results of electrochemical impedance spectroscopy (EIS) and galvanostatic cycling measurements show large changes in the cell without the presence of HMPA at higher temperatures (≥60 °C). Fourier transform infrared spectroscopy (FTIR) on the liquid and gas phase of the electrolyte shows without HMPA the formation of measurable amounts of PF 5 and HF. The complimentary results of these measurements proved the usefulness of using Lewis bases such as HMPA to inhibit the degradation of the electrolyte solution at elevated temperatures and potentially lead to improve cycle life of a nonaqueous capacitor. The results showed a large increase in capacitance retention during cycling (72% retention after 750,000 cycles). The results also provide evidence of major decomposition processes (0% capacitance retention after 100,000 cycles) that take place at higher temperatures without the additive of a thermal stability additive such as HMPA.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Medium-Voltage Testbed for Comparing Advanced Power Line Sensors vs. Measurement Transformers with Electrical Grid Events

Electrical utilities have relied upon potential transformers (PTs) and current transformers (CTs) for very accurate metering and to provide reliable signals for protective relays. Less expensive alternative sensing technologies offer the possibility of wider deployment, particularly in grids that employ distributed energy resources. In this work, the performance of an advanced medi-um-voltage sensor is compared with a reference PT and CT and experimentally evaluated for different power grid scenarios on an advanced outdoor power line sensor testbed at the US De-partment of Energy’s Oak Ridge National Laboratory. The sensor is based on a capacitive divider for voltage monitoring and a Rogowski coil with integrator for current monitoring. The advanced outdoor power line sensor testbed has a real-time simulator that was used to generate transient scenarios (e.g., electrical faults, capacitor bank operation, service restoration), while the analog signals were recorded by the same high resolution power meter. The behavior of analog signals, harmonic components, total harmonic distortion, and crest factors were assessed for this power line sensor compared with the reference PT/CT, because of the absence for testing standards for advanced outdoor power line sensors.

Piesciorovsky, Emilio↗