Search NASA⌕ Search

SEARCH · Search NASA

Results for “High Voltage Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

High Power Thruster Based on Inductive Magnetized Plasmoid Acceleration

Regardless of the power source, deep space missions will require both high specific impulse (greater than 500 s) and high thrust power (greater than 100kW). These high Isp thrusters will need to have high electrical efficiency (approx. 90%) and low specific mass (alpha approximately less than 10 kg/kW) as well. Additionally they should have high thrust to allow greater mission flexibility. All these requirements can potentially be achieved with the pulsed formation and acceleration of magnetically self-confined plasmoids commonly referred to as compact toroids (CTs). An electromagnetic plasma thruster based on CT acceleration makes an ideal candidate for a high power, high Isp thruster, since the CT is magnetically isolated from the accelerator so that there is no contact between the propellant and the accelerator. The transfer of momentum to the CT occurs through an electromagnetic interaction with the magnetic field. By maintaining an axial magnetic field gradient across it, the directed velocity of the CT can be increased indefinitely. In previous experiments carried out at the University of Washington, CT's of near milligram mass were accelerated to velocities of 250 km/s in a single pulse. The ejection of the plasmoid by an external axial field also avoids the serious problem of detachment, which would occur in thrusters that employ a magnetic mirror or magnetic nozzle. To employ the CT for propulsion, one must design, construct and test a plasma source that is capable of generating a self-confined plasma inductively, and to do it repeatedly at a sufficiently high rep rate. A repetitively pulsed 100 kW level FRC thruster was built and was operated for short bursts at a 10 kHz rep rate and will be described. Another regime for the FRC thruster however is to produce an FRC in a more conventional manner at high voltage and magnetic field. With the large energy transfer with each pulse, the rep rate for this approach is much lower (approximately 100 Hz). This is the approach that is being evaluated at MSFC in the FAST experiment. The purpose of this experiment is to build an FRC thruster, measure its performance characteristics e.g. specific impulse, thrust, and efficiency. This experiment will also be described as well as various mission scenarios that that are well matched for this type of propulsion.

Slough, John↗

Single Axis Piezoceramic Gimbal

This paper describes the fabrication, testing, and analysis of a single axis piezoceramic gimbal. The fabrication process consists of pre-stressing a piezoceramic wafer using a high-temperature thermoplastic polyimide and a metal foil. The differential thermal expansion between the ceramic and metal induces a curvature. The pre-stressed, curved piezoceramic is mounted on a support mechanism and a mirror is attached to the piezoceramic. A plot of gimbal angle versus applied voltage to the piezoceramic is presented. A finite element analysis of the piezoceramic gimbal is described. The predicted gimbal angle versus applied voltage is compared to experimental results.

Horner, Garnett↗

Operation of SOI P-Channel Field Effect Transistors, CHT-PMOS30, under Extreme Temperatures

Electronic systems are required to operate under extreme temperatures in NASA planetary exploration and deep space missions. Electronics on-board spacecraft must also tolerate thermal cycling between extreme temperatures. Thermal management means are usually included in today s spacecraft systems to provide adequate temperature for proper operation of the electronics. These measures, which may include heating elements, heat pipes, radiators, etc., however add to the complexity in the design of the system, increases its cost and weight, and affects its performance and reliability. Electronic parts and circuits capable of withstanding and operating under extreme temperatures would reflect in improvement in system s efficiency, reducing cost, and improving overall reliability. Semiconductor chips based on silicon-on-insulator (SOI) technology are designed mainly for high temperature applications and find extensive use in terrestrial well-logging fields. Their inherent design offers advantages over silicon devices in terms of reduced leakage currents, less power consumption, faster switching speeds, and good radiation tolerance. Little is known, however, about their performance at cryogenic temperatures and under wide thermal swings. Experimental investigation on the operation of SOI, N-channel field effect transistors under wide temperature range was reported earlier [1]. This work examines the performance of P-channel devices of these SOI transistors. The electronic part investigated in this work comprised of a Cissoid s CHT-PMOS30, high temperature P-channel MOSFET (metal-oxide semiconductor field-effect transistor) device [2]. This high voltage, medium-power transistor is designed for geothermal well logging applications, aerospace and avionics, and automotive industry, and is specified for operation in the temperature range of -55 C to +225 C. Table I shows some specifications of this transistor [2]. The CHT-PMOS30 device was characterized at various temperatures over the range of -190 C to +225 C in terms of its voltage/current characteristic curves. The test temperatures included +22, -50, -100, -150, -175, -190, +50, +100, +150, +175, +200, and +225 C. Limited thermal cycling testing was also performed on the device. These tests consisted of subjecting the transistor to a total of twelve thermal cycles between -190 C and +225 C. A temperature rate of change of 10 C/min and a soak time at the test temperature of 10 minutes were used throughout this work. Post-cycling measurements were also performed at selected temperatures. In addition, re-start capability at extreme temperatures, i.e. power switched on while the device was soaking for a period of 20 minutes at the test temperatures of -190 C and +225 C, was investigated.

Patterson, Richard↗

Simple Ion Channels: From Structure to Electrophysiology and Back

A reliable way to establish whether our understanding of a channel is satisfactory is to reproduce its measured ionic conductance over a broad range of applied voltages in computer simulations. In molecular dynamics (MD), this can be done by way of applying an external electric field to the system and counting the number of ions that traverse the channel per unit time. Since this approach is computationally very expensive, we have developed a markedly more efficient alternative in which MD is combined with the electrodiffusion (ED) equation. In this approach, the assumptions of the ED equation can be rigorously tested, and the precision and consistency of the calculated conductance can be determined. We have demonstrated that the full current/voltage dependence and the underlying free energy profile for a simple channel can be reliably calculated from equilibrium or non-equilibrium MD simulations at a single voltage. To carry out MD simulations, a structural model of a channel has to be assumed, which is an important constraint, considering that high-resolution structures are available for only very few simple channels. If the comparison of calculated ionic conductance with electrophysiological data is satisfactory, it greatly increases our confidence that the structure and the function are described sufficiently accurately. We examined the validity of the ED for several channels embedded in phospholipid membranes - four naturally occurring channels: trichotoxin, alamethicin, p7 from hepatitis C virus (HCV) and Vpu from the HIV-1 virus, and a synthetic, hexameric channel, formed by a 21-residue peptide that contains only leucine and serine. All these channels mediate transport of potassium and chloride ions. It was found that the ED equation is satisfactory for these systems. In some of them experimental and calculated electrophysiological properties are in good agreement, whereas in others there are strong indications that the structural models are incorrect.

molecular dynamics (MD↗

Operational Results of Pulse Shaping Techniques for the High Voltage Convertor Modulator

The High Voltage Converter Modulators (HVCMs) are used to power the RF klystrons used throughout the accelerator systems at Spallation Neutron Source (SNS). The output voltage of the HVCM has significant droop and ripple which, combined with low level RF (LLRF) system limitations, affect performance and efficiency of accelerator cavities. In conjunction with the progress in development of the new HVCM controller, different pulse modulation techniques were implemented and studied on the test modulator. This paper discusses the results of implementation of frequency modulation and phase modulation on output voltage. Operational data, including full average power operation, of test modulator is also discussed. Future plans for the new modulation scheme will be presented.

Patel, Gunjan P↗

Hydrogen Transport from Dielectrics to poly-Si/SiOx Passivating Contacts Measured by Mass Spectrometry and Vibrational Spectroscopy

We demonstrate the relationship between Si solar cell passivation and hydrogen content of various passivating films, including hydrogenated amorphous silicon (a-Si:H), aluminum oxide (Al2O3), silicon nitride (SiNx) and combinations thereof. Through isotopic studies using quadrupole mass spectrometry (QMS), Fourier transform infrared spectroscopy (FTIR), and Raman spectroscopy, we determine how hydrogen content and stability within each type of film relates to final passivation quality of solar cell test structures. Si solar cells using polycrystalline silicon on silicon oxide (poly-Si/SiOx) passivating contacts are at the forefront of Si solar cell research and emerging as top performers within industrial production. Performance of passivating contact Si solar cells is largely determined by a parameter known as the open-circuit voltage Voc, which directly relates to material quality within the bulk of the device and at surfaces. High Voc is achieved when defects within the bulk crystalline silicon (c-Si) and at interfaces are passivated, preventing them from acting as charge carrier recombination centers. One of the most important means of passivating defects within Si solar cells is via hydrogenation, injecting the cells with large amounts of H to satisfy dangling bonds in the bulk and at interfaces. Hydrogen is especially important in deactivating a prevalent defect in industrial p-type devices which leads to decreased device performance over long-term exposure to light, called light-induced degradation (LID). Some of the most common materials used to supply H to devices are a-Si:H, Al2O3, and SiNx, which can contain very large amounts of H. Upon annealing at elevated temperatures, the hydrogen becomes mobile enough to find and disable defect sites. However, too much hydrogen can also be problematic, sometimes leading to an effect called light and elevated temperature induced degradation (LeTID). It has been shown that these films passivate the interfaces of poly-Si passivating contacts differently, leading to differing performance. Though Al2O3 is a well-defined dielectric material, SiNx can have many different values of x depending on precursor gases and deposition conditions. We observe different FTIR and Raman spectra from different SiNx over a range of x values films to determine the bonding environments within them and further correlate the relative concentrations of Si, N, and H to the stability of H within SiNx and the passivation performance of each film. Because deuterium is chemically identical to hydrogen within these systems, but gives different signals in FTIR and Raman spectroscopy as well as in QMS, isotopic substitution can be used as an excellent tool to probe the H within films. In addition to measuring the H and D bonding within films using FTIR and Raman spectroscopy, we will use such isotopic experiments to observe H and D movement out of these hydrogenating films at elevated temperatures using QMS to determine the stability of H bonding within such systems. With these films characterized based on elemental composition, we will relate such measurements to passivation quality of these films and combinations thereof on poly-Si/SiOx contact structures using quasi-steady state photoconductance decay measurements to obtain implied open-circuit voltage (iVoc) and saturation current density J0 values. Such investigations into the performance of different passivating films and film stacks will lead to greater understanding of dielectrics in semiconductor devices, further improvements in passivated contact design, and eventually, greater proliferation of renewable solar energy worldwide.

Al2O3↗

Modified Magnicon for High-Gradient Accelerator \&

A self-consistent design is described of a modified 34.3 GHz magnicon amplifier with a TE311-mode output cavity, to replace the existing magnicon at Yale Beam Physics Lab Test Facility whose output cavity operates in the TM310 mode. The main g oal for the new design is to achieve robust reliable operation. This is expected since tube performance according to simulations is largely insensitive to the magnitude of external dc magnetic fields, including imperfections in magnetic field profile; small changes in gun voltage and current; changes in electron beam radial size; and even poorly matched external circuitry. The new tube, as with its predecessor, is a third harmonic amplifier, with drive and deflection gain cavities near 11.424 GHz and output cavity at 34.272 GHz. The design calculations predict stable output of power of 20-27 MW at a 10 Hz repetition rate in pulses up to 1.3 microsec long, with a low probability of breakdown in the output cavity because of low electric fields (less tha n 650 kV/cm).

43 PARTICLE ACCELERATORS↗

A Flux Balancing Strategy for 10-kV SiC-Based Dual-Active-Bridge Converter

The transformer flux unbalance in dual-active-bridge (DAB) converters is a critical issue due to the electrical parameter and modulation mismatch, and load or control transients. Compared to low voltage DAB converters, the unbalance problem in medium voltage DAB converters may cause more severe problem, and become more difficult to deal with, because of the high operating voltage and insulation requirement. In this paper, a flux balancing strategy for a medium voltage (MV) DAB converter is proposed, including the transformer design with ferrite gap, current harmonic-based unbalance detection, as well as the flux balancing control scheme. With the proposed ferrite gap, nonlinear magnetizing current and its modeling are induced. Then, by analyzing the current harmonics, the flux unbalance level can be detected, and hence controlled. Test results have verified the proposed method in a MV DAB converter.

Gao, Zihan↗

Mitigation of PtCo/C Cathode Catalyst Degradation via Control of Relative Humidity

Maintaining the high performance of proton-exchange membrane fuel cells (PEMFC) over the course of its lifetime is a key enabling factor for its successful commercialization as a primary power source in zero-emission transportation applications. In this context, it is important to mitigate the degradation of PtCo-alloy based cathode catalysts used for oxygen reduction reaction (ORR). PtCo-alloy catalysts exhibit high activity at beginning-of-life (BOL) which tends to decrease during operation due to loss of electrochemical surface area (ECSA) and dissolution-contamination related effects of the Co-alloying component. Here, we demonstrate the use of relative humidity (RH) of the inlet gases as a controllable parameter to mitigate the degradation of PtCo-alloy catalyst degradation. We employ a catalyst-specific voltage cycling accelerated stress test (AST) durability protocol as a function of inlet RH to degrade PtCo catalysts. A series of in situ electrochemical diagnostics and ex situ characterizations have been carried out to investigate the catalyst layer characteristics at end-of-test (EOT). Our results show that at sub-saturated conditions of durability protocol operation, PtCo catalyst sustains higher EOT H 2 /air performance due to better retention of ECSA and smaller impact of Co 2+ dissolution/contamination.

25 ENERGY STORAGE↗

NASA Tech Briefs, February 2012

This issue contains the following briefs: (1) Optical Comb from a Whispering Gallery Mode Resonator for Spectroscopy and Astronomy Instruments Calibration (2) Real-Time Flight Envelope Monitoring System (3) Nemesis Autonomous Test System (4) Mirror Metrology Using Nano-Probe Supports (5) Automated Lab-on-a-Chip Electrophoresis System (6) Techniques for Down-Sampling a Measured Surface Height Map for Model Validation (7) Multi-Component, Multi-Point Interferometric Rayleigh/Mie Doppler Velocimeter (8) Frequency to Voltage Converter Analog Front-End Prototype (9) Dust-Tolerant Intelligent Electrical Connection System (10) Gigabit Ethernet Asynchronous Clock Compensation FIFO (11) High-Speed, Multi-Channel Serial ADC LVDS Interface for Xilinx Virtex-5 FPGA (12) Glovebox for GeoLab Subsystem in HDU1-PEM (13) Modified Process Reduces Porosity when Soldering in Reduced Gravity Environments (14) Use of Functionalized Carbon Nanotubes for Covalent Attachment of Nanotubes to Silicon (15) Flexible Plug Repair for Shuttle Wing Leading Edge (16) Three Dimensionally Interlinked, Dense, Solid Form of Single-Walled CNT Ropes (17) Axel Robotic Platform for Crater and Extreme Terrain Exploration (18) Site Tamper and Material Plow Tool - STAMP (19) Magnetic Interface for Segmented Mirror Assembly (20) Transpiration-Cooled Spacecraft-Insulation-Repair Fasteners (21) Fluorescence-Based Sensor for Monitoring Activation of Lunar Dust (22) Aperture Ion Source (23) Virtual Ultrasound Guidance for Inexperienced Operators (24) Model-Based Fault Diagnosis: Performing Root Cause and Impact Analyses in Real Time (25) Interactive Schematic Integration Within the Propellant System Modeling Environment (26) Magnetic and Electric Field Polarizations of Oblique Magnetospheric Chorus Waves (27) Variable Sampling Mapping.

Source record↗

Ultra-high-voltage Ni-rich layered cathodes in practical Li metal batteries enabled by a sulfonamide-based electrolyte

By increasing the charging voltage, a cell specific energy of >400 Wh kg-1 is in principle achievable with LiNi0.8Mn0.1Co0.1O2 in lithium-metal batteries (LMBs). However, stable cycling of high-nickel cathodes at ultra-high voltages is extremely challenging. Here we report that a rationally designed sulfonamide-based electrolyte enables stable cycling of commercial LiNi0.8Co0.1Mn0.1O2 with a cut-off voltage up to 4.7 V in LMBs. In contrast to commercial carbonate electrolytes, the electrolyte not only suppresses side reactions, intergranular cracking, transition-metal dissolution, and impedance growth on the cathode side, but also enables highly reversible Li metal stripping and plating leading to compact morphology and low pulverization. Our LMB delivers a specific capacity >230 mAh g-1 and an average Coulombic efficiency >99.65% over 100 cycles. Even under harsh testing conditions, the 4.7 V LMB can retain >88% capacity for 90 cycles, demonstrating significant advances in practical LMBs.

36 MATERIALS SCIENCE↗

An ion thruster internal discharge chamber electrostatic probe diagnostic technique using a high-speed probe positioning system

Extensive resources have been allocated to diagnose and minimize lifetime-limiting factors in gridded ion thrusters. While most of this effort has focused on grid erosion, results from wear tests indicate that discharge cathode erosion may also play an important role in limiting the lifetime of ring-cusp ion thrusters proposed for future large flagship missions. The detailed characterization of the near-cathode discharge plasma is essential for mitigating discharge cathode erosion. However, severe difficulty is encountered when attempting to measure internal discharge plasma parameters during thruster operation with conventional probing techniques. These difficulties stem from the high-voltage, high-density discharge cathode plume, which is a hostile environment for probes. A method for interrogating the discharge chamber plasma of a working ion thruster over a two-dimensional grid is demonstrated. The high-speed axial reciprocating probe positioning system is used to minimize thruster perturbation during probe insertion and to reduce heating of the probe. Electrostatic probe measurements from a symmetric double Langmuir probe are presented over a two-dimensional spatial array in the near-discharge cathode assembly region of a 30-cm-diameter ring-cusp ion thruster. Electron temperatures, 2-5 eV, and number density contours, with a maximum of 8x10{sup 12} cm{sup -3} on centerline, are measured. These data provide detailed electron temperature and number density contours which, when combined with plasma potential measurements, may shed light on discharge cathode erosion processes and the effect of thruster operating conditions on erosion rates.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A cryogenically cooled 200 kV DC photoemission electron gun for ultralow emittance photocathodes

Novel photocathode materials like ordered surfaces of single crystal metals, epitaxially grown high quantum efficiency thin films, and topologically non-trivial materials with dirac cones show great promise for generating brighter electron beams for various accelerator and ultrafast electron scattering applications. Despite several materials being identified as brighter photocathodes, none of them have been tested in electron guns to extract electron beams due to technical and logistical challenges. In this paper, we present the design and commissioning of a cryocooled 200 kV DC electron gun that is capable of testing a wide variety of novel photocathode materials over a broad range of temperatures from 298 to 35 K for bright electron beam generation. This gun is designed to enable easy transfer of the photocathode to various standard ultra-high-vacuum surface diagnostics and preparation techniques, allowing a full characterization of the dependence of beam brightness on the photocathode material and surface properties. We demonstrate the development of such a high-voltage, high-gradient gun using materials and equipment that are easily available in any standard university lab, making the development of such 200 kV electron guns more accessible.

Instruments & Instrumentation↗

An 18 Element Strip of 1 mm$^{2}$ G-APDs for CMS HCAL upgrade results of CERN Test Beam 2009

The Compact Muon Solenoid hadronic barrel (CMS HB) calorimeter consists of 17 layers of scintillator in a brass absorber. Each scintillator consists of 16 tiles comprising one layer of the corresponding towers in pseudo-rapidity. The light from each tile is routed into a single 0.96 mm wavelength shifting fiber. In the current design, the 17 fibers from the full tower depth are directed into one pixel of a multi-channel hybrid photo-diode (HPD). Thus, no longitudinal shower information is readout. In the last year we have developed 18 element MAPD arrays (Micro-pixel Avalanche Photo Diodes) on 8 inch wafers with Zecotek in Singapore. A special prototype 20 pin ceramic package was made by Kyocera in Germany. By using 18 element G-APD strips (Geiger mode Avalanche photo diodes) we could readout each layer separately, so that 17 of these strips replace one HPD. Because of the large linear range requirement in the hadronic calorimeter and radiation hardness needed, we used the new generation high cell density Zecotek MAPDs with 15,000 cells per strip element. Due to the higher PDE (photon detection efficiency) versus the HPD (30% vs. 12%) we got 5 p.e. per layer for a MIP. Due to limited availability of electronic channels for these tests, analog signals from multiple strips were added together providing digital readout from four depth segments. Non uniformity between strips was calibrated using muons and measurements of breakdown voltage of each element of the array. After calibration of the 4 longitudinal depth segments, the linearity and detector resolution was studied using pions with energies from 30 to 300 GeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ensuring a Nuclear Power Plant Safe State Following an EMP Event - Task 7 Deliverable: EMP Testing of Secondary Coupling to Instrumentation Cables

Sandia National Laboratories performed tests to address the potential vulnerability concerns of a coupled High-Altitude Electromagnetic Pulse (HEMP) inducing secondary coupling onto critical instrumentation and control cables in a nuclear power plant, with specific focus on early-time HEMP. Three types of receiving cables in nine configurations were tested to determine transfer functions between two electrically separated cables referenced to the common mode input current on the transmitting cable. One type of transfer function related the input short circuit current and resulting open circuit voltage on the receiving cable. The other transfer function related the input short circuit current and the resulting short circuit current on the receiving cable. A 500 A standard HEMP waveform was input into the transfer functions to calculate peak coupling values on the receiving cables. The highest level of coupling using the standard waveform occurred when cables were in direct contact, with a peak short circuit current of 85 A and open circuit voltage of 9.8 kV, while configurations with separated cables predicted coupling levels of less than 5 A or 500 V.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Quench Propagation on Rare-Earth Barium Copper Oxide (REBCO) Tape

Rare-earth barium copper oxide (REBCO) high-temperature superconductors can carry high currents with zero electrical resistance, enabling applications in high-field magnets, energy systems, and fusion devices. However, the localized losses of superconductivity called a quench pose a severe risk due to REBCO’s mechanical brittleness and slow quench propagation, hence complicating early detection. This work investigates quench propagation and thermal response through controlled experiments. A segmented REBCO tape soldered on a PCB with multiple voltage taps and temperature sensors was submerged in liquid nitrogen at 77 K. In the first test, current ramping produced a quench near 360 A, consistent with theoretical current limits but resulted in a local burn. In the second test, a heater-induced quench at 300 A propagated bidirectionally with measured velocities ranging from 164–226 mm/s. These measurements provide critical parameters for improving REBCO quench detection and protection system design with accounts for REBCO's limited bendability.

Ju, Han [NIU, DeKalb]↗

Physics-Based Method for Generating Fully Synthetic IV Curve Training Datasets for Machine Learning Classification of PV Failures

Classification machine learning models require high-quality labeled datasets for training. Among the most useful datasets for photovoltaic array fault detection and diagnosis are module or string current-voltage (IV) curves. Unfortunately, such datasets are rarely collected due to the cost of high fidelity monitoring, and the data that is available is generally not ideal, often consisting of unbalanced classes, noisy data due to environmental conditions, and few samples. In this paper, we propose an alternate approach that utilizes physics-based simulations of string-level IV curves as a fully synthetic training corpus that is independent of the test dataset. In our example, the training corpus consists of baseline (no fault), partial soiling, and cell crack system modes. The training corpus is used to train a 1D convolutional neural network (CNN) for failure classification. The approach is validated by comparing the model’s ability to classify failures detected on a real, measured IV curve testing corpus obtained from laboratory and field experiments. Results obtained using a fully synthetic training dataset achieve identical accuracy to those obtained with use of a measured training dataset. When evaluating the measured data’s test split, a 100% accuracy was found both when using simulations or measured data as the training corpus. When evaluating all of the measured data, a 96% accuracy was found when using a fully synthetic training dataset. The use of physics-based modeling results as a training corpus for failure detection and classification has many advantages for implementation as each PV system is configured differently, and it would be nearly impossible to train using labeled measured data.

Hopwood, Michael W. (ORCID:0000000161901767)↗

The advantages of the high voltage solar array for electric propulsion

The high voltage solar array (HVSA) offers improvements in efficiency, weight, and reliability for the electric propulsion power system. The basic HVSA technology involves designing the solar array to deliver power in the form required by the ion thruster. This paper delves into conventional power processes and problems associated with ion thruster operation using SERT II experience for examples. In this light, the advantages of the HVSA concept for electric propulsion are presented. Tests conducted operating the SERT II thruster system in conjunction with HVSA are discussed. Thruster operation was observed to be normal and in some respects improved.

Sater, B. L.↗