Search NASA⌕ Search

SEARCH · Search NASA

Results for “Operating Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Subtask 2.6 – Optimization of Aerosol Mitigation Technology for Postcombustion CO 2 Capture

Growing concerns over the impact of CO 2 emissions from combustion sources on global climate change have prompted numerous research and development projects aimed at developing cost-effective technologies for CO 2 capture. One family of technologies being demonstrated at pilot and full scale globally is postcombustion CO 2 capture (PCCC) systems that employ amine-based solvents. The captured CO 2 can be compressed and permanently stored underground or used for enhanced oil recovery (EOR). The proximity of North Dakota’s lignite-fired fleet of power plants to potential CO 2 storage options creates a unique atmosphere for PCCC within the state. However, the aerosols present in lignite flue gas present a challenge for large-scale PCCC at North Dakota power plants. Aerosols can negatively impact the long-term performance of amine-based solvents for CO 2 capture. Amine-based solvents are volatile, and aerosols provide nucleation sites where amine vapors can condense. Because aerosols cannot be easily captured at the column outlet using conventional technologies, the amine-laden aerosols escape the system and lead to accelerated solvent losses. Moreover, aerosol components can chemically react with amines to form degradation products that can permanently deactivate the amine, cause fouling, and lead to hazardous emissions. Many of the elements that have been shown to catalyze solvent degradation are present in lignite coals and can exacerbate solvent replacement economics. Understanding this issue is critical to the implementation of solvent-based CO 2 capture systems as applied to lignite-fired generation systems. The Energy & Environmental Research Center (EERC) designed and carried out this project to optimize aerosol mitigation technology for PCCC at a lignite-fired power plant. To meet the goal of this project, the following objectives were identified: Determine the effectiveness of a wet electrostatic precipitator (WESP) on collection of aerosols at a low-rank coal-fired power station. Determine the impact of aerosols on the efficiency and degradation products of amine-based carbon capture systems fired with low-rank fuels. Work was conducted at Minnkota Power Cooperative’s (MPC’s) Milton R. Young (MRY) Station Unit 2 using a slipstream of flue gas from the outlet of the plant’s flue gas desulfurization (FGD) unit. To gather initial data for sizing and specifying a WESP for this system, a temporary pilot-scale WESP was rented and installed on-site. Several different conditions were tested to examine the impact of flow rate, voltage, and current on WESP performance. The WESP was effective at removing large particulate (>200 nm) but caused an increase in fine particulate (<75 nm). Fine particulate material at the inlet and outlet of the WESP was collected, analyzed, and showed that crystalline sulfates carried over from the plant’s FGD unit were being converted to fine aerosols and SO 2 was being converted to SO 3 through the WESP. Additionally, the high moisture content of the flue gas stream at this sample location also contributed to an overall increase in aerosol mass under some of the test conditions. Using the results from the rented WESP, the project team installed a smaller-scale WESP upstream of the EERC’s slipstream CO 2 capture system. Flue gas was routed through a pilot-scale FGD unit to remove SO 2 to very low levels (~1 ppm) and then through a direct contact cooler (DCC) to further cool the gas and to remove moisture. The gas exiting the DCC was then routed through the new WESP before passing to the CO 2 absorber columns. Fluor’s amine-based solvent was used to scrub CO 2 from the slipstream through a set of two absorber columns. The rich solvent was regenerated in a stripper column by heating to drive off captured CO 2 . The system operated using a catch-and-release method where the CO 2 was separated to provide data on the process, but the captured CO 2 was released back into the host site stack. Aerosols and sulfur species were measured at multiple locations throughout the pilot-scale system. The inlet FGD and DCC removed much of the particulate matter and gaseous sulfur upstream of the WESP. With this configuration, the WESP achieved >95% particulate capture. The new WESP did not show any of the increases in SO 3 or other aerosol species that had been consistently observed with the larger-scale WESP installed immediately downstream of the plant’s full-scale FGD unit. Particulate samples captured and analyzed from the WESP inlet did not show any presence of crystalline sulfate materials, indicating that the pilot-scale FGD and DCC were efficient at reducing carryover from the plant’s full-scale FGD unit. A set of parametric tests were conducted on the new WESP to assess the impacts of flow rate, voltage, number of online WESP fields, and gas-phase sulfur content on aerosol and sulfur transformations. The results showed that the WESP performed similarly well at all sets of conditions. Sulfur and particulate matter exiting the WESP were further reduced through the absorber column as the amine-based solvent captured some of the residual contaminants. Solvent analysis showed that these species were slowly concentrating in the solvent over the duration of the test. When the WESP was taken offline and the sulfur slip through the FGD allowed to rise, the sulfate content in the solvent rose sharply, showing that the extra FGD and WESP were effective at reducing sulfate and cation uptake. This would be expected to extend amine-based solvent life by slowing the formation of heat-stable salts and other degradation products. This subtask was cofunded through the EERC–U.S. Department of Energy Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FE0024233. Nonfederal funding was provided by the North Dakota Industrial Commission and MPC.

01 COAL, LIGNITE, AND PEAT↗

Distribution Grid Incentive Design with Unknown Agent Behavior

Motivation: During extreme events, traditional grid regulation methods (e.g., energy prices, net power injection limits) may be insufficient. While system operators typically lack control over end-user grid interactions, (e.g., energy demand), incentives can influence behavior - for example, a user that receives a grid-driven incentive may adjust their consumption or expose relevant control variables in response. Problem: Optimize for the best incentive subject to system stability constraints. However, user behavior is unknown to the SO - i.e., for a given incentive, the amount of curtailed load or control variables exposed is unknown.

feedback based control↗

Large-Scale Simulation of Regional Demand Flexibility Implementation and Customer Economic Impact

The Distribution System Operator with Transactive (DSO+T) study conducted a large-scale simulation of over 60,000 customers in a region the size of Texas to demonstrate the effective coordination of distributed energy resources (DERs) in commercial and residential buildings. The integrated simulation included both the bulk (wholesale generation and transmission) and distribution systems. The DERs (including batteries, electric vehicles, air conditioning, and water heaters) participated in a transactive energy retail market that was integrated into an existing competitive wholesale market. The engineering and economic performance of the resulting demand flexibility was evaluated over annual simulations for both moderate and high renewable generation scenarios. A detailed parametric cost model was developed to enable detailed economic analysis of key stakeholders. In addition, fixed and dynamic customer tariffs were designed and applied to the customer population. This allowed the impact on annual customer bills to be analyzed for various building types (residential versus commercial; single- versus multi-family). This paper presents results showing the relative flexibility of batteries, electric vehicles, and building loads throughout the year and under different renewable scenarios. This feeds a detailed breakdown of the impact this flexibility has on the operating costs of the grid and the resulting net economic benefit. Finally, the study showed that practically all customer classes (including non-participating customers) save money under the proposed demand flexibility scheme. The study found overall net annual economic savings of $3.3-5.0B for a region the size of Texas equating to average customer bill savings of 10-16%.

Reeve, Hayden M.↗

Investigating the effects of cooperative transmission expansion planning on grid performance during heat waves with varying spatial scales

There is growing recognition of the advantages of interregional transmission capacity to decarbonize electricity grids. A less explored benefit is potential performance improvements during extreme weather events. This study examines the impacts of cooperative transmission expansion planning using an advanced modeling chain to simulate power grid operations of the United States Western Interconnection in 2019 and 2059 under different levels of collaboration between transmission planning regions. Two historical heat waves in 2019 with varying geographical coverage are replayed under future climate change in 2059 to assess the transmission cooperation benefits during grid stress. The results show that cooperative transmission planning yields the best outcomes in terms of reducing wholesale electricity prices and minimizing energy outages both for the whole interconnection and individual transmission planning regions. Compared to individual planning, cooperative planning reduces wholesale electricity prices by 64.3 % and interconnection-wide total costs (transmission investments + grid operations) by 34.6 % in 2059. It also helps decrease greenhouse gas emissions by increasing renewable energy utilization. However, the benefits of cooperation diminish during the widespread heat wave when all regions face extreme electricity demand due to higher space cooling needs. Despite this, cooperative transmission planning remains advantageous, particularly for California Independent System Operator with significant diurnal solar generation capacity. This study suggests that cooperation in transmission planning is crucial for reducing costs and increasing reliability both during normal periods and extreme weather events. It highlights the importance of optimizing the strategic investments to mitigate challenges posed by wider-scale extreme weather events of the future.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Spinning reserve from hotel load response

Even though preliminary tests were not conducted during times of highest system or hotel loading during the summer, they showed that hotel load can be curtailed by 22 to 37 percent depending on the outdoor temperature and time of day. Full response occurred in 12 to 60 seconds from when the system operator's command to shed load was issued and the load drop was very rapid. (author)

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Evaluation of information technology impact on effective internal control in the University system

Information Technology (IT) plays a key role in internal control system in various organizations in terms of maintaining records and other internal services. Internal control system is defined as an efficient control procedures set up by firm to safeguard resources and to assure the reliability and accuracy of both financial and non-financial records in line with applicable governance and procedure to acquire the established goal and objectives. This paper focuses on the impact of IT on internal control system in the Nigerian universities. Data are collected from three different universities via questionnaire. Descriptive statistics is used to analyze the data; Chi-square is performed to test the hypothesis. The results of the hypothesis showed that IT has a positive relationship with the effective internal control activities in the University system. It is concluded that the adoption of IT will significantly improve the effectiveness of the internal control system operations in the University in terms of quality service delivery.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Phase locking of a seven-channel continuous wave fibre laser system by a stochastic parallel gradient algorithm

A seven-channel fibre laser system operated by the master oscillator – multichannel power amplifier scheme is the phase locked using a stochastic parallel gradient algorithm. The phase modulators on lithium niobate crystals are controlled by a multichannel electronic unit with the microcontroller processing signals in real time. The dynamic phase locking of the laser system with the bandwidth of 14 kHz is demonstrated, the time of phasing is 3 – 4 ms. (fibre and integrated-optical structures)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

IGMS: An Integrated ISO-to-Appliance Scale Grid Modeling System

This paper describes the Integrated Grid Modeling System (IGMS), a novel electric power system modeling platform for integrated transmission-distribution analysis that co-simulates off-the-shelf tools on high performance computing (HPC) platforms to offer unprecedented resolution from ISO markets down to appliances and other end uses. Specifically, the system simultaneously models hundreds or thousands of distribution systems in co-simulation with detailed Independent System Operator (ISO) markets and AGC-level reserve deployment. IGMS uses a new MPI-based hierarchical co-simulation framework to connect existing sub-domain models. Our initial efforts integrate opensource tools for wholesale markets (FESTIV), bulk AC power flow (MATPOWER), and full-featured distribution systems including physics-based end-use and distributed generation models (many instances of GridLAB-D[TM]). The modular IGMS framework enables tool substitution and additions for multi-domain analyses. This paper describes the IGMS tool, characterizes its performance, and demonstrates the impacts of the coupled simulations for analyzing high-penetration solar PV and price responsive load scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Neutronics and computational fluid dynamics analyses for a natural circulation loop of molten fuel salt

A conceptual reactor system of molten fuel salt loop designed for Mo-99 production was analyzed by coupling TRITON neutronics and Fluent computational fluid dynamics (CFD) simulations. The loop system operated in 1 MW thermal power features natural circulation and potential extraction of non-soluble fission products (FP) in fuel salt. The behavior of natural circulation was studied and the power and temperature distributions in equilibrium were obtained. A long-term fuel depletion analysis of the system considering fuel circulation and reprocessing was then performed using an approximate stepwise sequence of simulations. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A microbenchmark characterization of the Emu chick

The Emu Chick is a prototype system designed around the concept of migratory memory-side processing. Rather than transferring large amounts of data across power-hungry, high-latency interconnects, the Emu Chick moves lightweight thread contexts to near-memory cores before the beginning of each memory read. The current prototype hardware uses FPGAs to implement cache-less “Gossamer” cores for computational work and rely on a typical stationary core (PowerPC) to run basic operating system functions and migrate threads between nodes. In this multi-node characterization of the Emu Chick, we extend an earlier single-node investigation of the the memory bandwidth characteristics of the system through benchmarks like STREAM, pointer chasing, and sparse matrix-vector multiplication. Here, we compare the Emu Chick hardware to architectural simulation and an Intel Xeon-based platform. Our results demonstrate that for many basic operations the Emu Chick can use available memory bandwidth more efficiently than a more traditional, cache-based architecture although bandwidth usage suffers for computationally intensive workloads like SpMV. Moreover, the Emu Chick provides stable, predictable performance with up to 65% of the peak bandwidth utilization on a random-access pointer chasing benchmark with weak locality.

97 MATHEMATICS AND COMPUTING↗

Electric Bike Sharing--System Requirements and Operational Concepts

Bike sharing is an exciting new model of public-private transportation provision that has quickly emerged in the past five years. Technological advances have overcome hurdles of early systems and cities throughout the globe are adopting this model of transportation service. Electric bikes have simultaneously gained popularity in many regions of the world and some have suggested that shared electric bikes could provide an even higher level of service compared to existing systems. There are several challenges that are unique to shared electric bikes: electric-assisted range, recharging protocol, and bike and battery checkout procedures. This paper outlines system requirements to successfully develop and deploy an electric bike sharing system, focusing on system architecture, operational concepts, and battery management. Although there is little empirical evidence, electric bike sharing could be feasible, depending on demand and battery management, and can potentially improve the utility of existing bike sharing systems. Under most documented bike sharing use scenarios, electric bike battery capacity is insufficient for a full day of operation, depending on recharging protocol. Off-board battery management is a promising solution to address this problem. Off-board battery management can also support solar recharging. Future pilot tests will be important and allow empirical evaluation of electric bikesharing system performance. (auth)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

New automated inventory/material accounting system (AIMAS) version for former Soviet Union countries

AIMAS (Automated Inventory/Material Accounting System) is a PC-based application for site-level nuclear material accountancy that was originally developed in the late 90's as a part of the U.S Department of Energy Assistance Program to Ukraine. Designed to be flexible and secure, plus place minimal demands on computing infrastructure, it was originally developed to run in early Windows operating system (OS) environments like W98 and W3.1. The development, support, and maintenance of AIMAS were transferred to Ukraine in 2002. Because it is highly flexible and can be configured to meet diverse end-user's needs, the software has been used at several facilities in Ukraine. Incorporating added functionality is planned to support nuclear installations in the Republic of Kazakhstan and Uzbekistan, as well. An improved 32-bit version of AIMAS has recently been developed to operate effectively on modern PCs running the latest Windows OS by AVIS, the Ukrainian developer. In the paper we discuss the status of AIMAS, plans for new functions, and describe the strategy for addressing a sustainable software life-cycle while meeting user requirements in multiple FSU countries.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

REPORT OF ON-SITE INSPECTION WORKSHOP-16

The central issue addressed by this workshop was the task of making the on-site inspection (OSI) part of the Comprehensive Nuclear-Test-Ban Treaty verification system operationally ready at entry into force of the Treaty. It is recognized, and this was emphasized by the 2008 OSI Integrated Field Exercise (IFE), that it is not possible to develop every part of the OSI regime simultaneously. Therefore, it is necessary to prioritize the approach to OSI readiness. The reviews of the IFE have pointed to many elements of OSI readiness that still need development. The objective of this workshop was to provide priorities for the path forward for Working Group B to consider. Several critical areas have been identified that are related to the development of OSI readiness: (1) Technology development: Priorities are radionuclide and noble gas sampling and analysis, visual observation, multispectral/infrared imaging methods, active seismic methods and the recognition of the importance of signatures. (2) Organizational development: Priorities are health and safety, the Operations Support Centre, the Equipment Storage and Maintenance Facility, information technology data flow and communications. (3) Resources: The expertise to develop key parts of the OSI regime is not available within the current OSI Division staff. To develop these aspects of the regime will require more staff or supplements to the staff with cost-free experts or other means. Aspects of the system that could benefit from more staff include radionuclide and noble gas detection methods, data flow and communications, visual observation, multispectral/infrared methods and health and safety. As the path forward, participants of this workshop recognized a need to optimize the development of OSI priorities. The outcome of this workshop is to suggest for consideration an operational approach to OSI readiness that utilizes results of an evaluation of the relative effectiveness of OSI elements versus their relative maturity. By integrating such an assessment with considerations of integrated operational capabilities and the anticipated level of inspection team self-sufficiency and measurable milestone criteria, a set of priorities for OSI development can be developed. Once these priorities have been established, the Policy Making Organs can decide upon the milestones, strategic plan and action plan to serve as guidance for implementation by the Provisional Technical Secretariat. The suggested operational approach is as follows: (1) Assess the relative effectiveness (importance) of OSI elements versus their relative maturity; (2) Determine the anticipated level of self-sufficiency; (3) Define measurable milestone criteria; and (4) Result: Milestones for OSI readiness.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

The Convergence of Vehicle Electrification and Automation - Enabling Sustainable Automated Mobility Districts

The transportation industry is entering a new frontier with three major simultaneous transformations: electrification, automation, and on-demand services. All three directly affect the same spaces of vehicle technology, infrastructure, and system operational performance. Further, each area of change adds its own driving forces of complexity to the others' design challenges. This paper explores these transformations, framing the implications for vehicle technology and infrastructure and their impact on operating concepts and strategies, which in turn impact the sustainability of the transportation infrastructure in the built environment. Specifically, this paper examines battery-electric vehicles operating in a fully automated fleet within an "automated mobility district" (AMD) setting with multiple on-demand services. From this examination, the paper assesses the implications for transportation electrification, comparing and contrasting traditional fixed-route services with those of on-demand transit and automated transit networks, including the trade-offs between vehicle range (battery capacity), charging parameters, power availability, and operations predictability with respect to policy and infrastructure configurations. The paper also addresses the configuration and management of boarding and alighting zones (also called pickup and drop-off zones), and the need for complementary infrastructure intelligence at intersections and curbs. Finally, conclusions are drawn with respect to the system integration and analysis needs for AMDs regarding resilience and sustainability of mobility infrastructure.

ADVANCED PROPULSION SYSTEMS↗

Transmission Optimization with Grid Enhancing Technologies Fact Sheet

The Transmission Optimization with Grid Enhancing Technologies (TOGETs) project is funded by the Department of Energy (DOE) Office of Electricity (OE) and Wind Energy Technologies Office (WETO). Idaho National Laboratory’s TOGET Task force consists of regulatory, utility, system operator, vendor, academic, and other industry participants, who will guide a two-pronged approach to fill in gaps on publicly available knowledge of GETs and conduct a full scale, multi-faceted field exercise. Ultimately the project aims to test, verify, and validate deployed GETs in a transmission system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Air Sample Conditioner Helps the Waste Treatment Plant Meet Emissions Standards

The air in three of the Hanford Site Waste Treatment and Immobilization Plant (WTP) melter off-gas discharge stacks will be hot and humid after passing through the train of emission abatement equipment. The off-gas temperature and humidity levels will be incompatible with the airborne emissions monitoring equipment required for this type of stack. To facilitate sampling from these facilities, an air sample conditioner system will be installed to introduce cool, dry air into the sample stream to reduce the temperature and dew point. This will avoid thermal damage to the instrumentation and problematic condensation. The complete sample transport system must also deliver at least 50% of the particles in the sample airstream to the sample collection and on-line analysis equipment. The primary components of the sample conditioning system were tested in a laboratory setting. The sample conditioner itself is based on a commercially-available porous tube filter design. It consists of a porous sintered metal tube inside a coaxial metal jacket. The hot gas sample stream passes axially through the porous tube, and the dry, cool air is injected into the jacket and through the porous wall of the inner tube, creating an effective sample diluter. The dilution and sample air mix along the entire length of the porous tube, thereby simultaneously reducing the dew point and temperature of the mixed sample stream. Furthermore, because the dilution air enters through the porous tube wall, the sample stream does not come in contact with the porous wall and particle deposition is reduced in this part of the sampling system. Tests were performed with an environmental chamber to supply air with the temperature and humidity needed to simulate the off-gas conditions. Air from the chamber was passed through the conditioning system to test its ability to reduce the temperature and dew point of the sample stream. To measure particle deposition, oil droplets in the range of 9 to 11 micrometer aerodynamic diameter were injected into the environmental chamber and drawn through the conditioning system, which included a filter to capture droplets that passed through the conditioner. The droplets were tagged with a fluorescent dye which allowed quantification of droplet deposition on each component of the system. The tests demonstrated the required reductions in temperature and moisture, with no condensation forming when heat tracing was added on the upstream end of the sample conditioner. Additionally, tests indicated that the system, operating at several flow rates and in both vertical and horizontal orientations, delivers nearly all of the sampled particles for analysis. Typical aerosol penetration values were between 98 and 99%. PNNL, Bechtel National Inc., and the instrument vendor are working to implement the sample conditioner into the air monitoring systems used for the melter off-gas exhaust streams. Similar technology may be useful for processes in other facilities with air exhaust streams with elevated temperature and/or humidity.

sample conditioning↗

AI-ENABLED MONITORING OPTIONS TOWARDS SECURE MICROREACTOR DEPLOYMENT AND OPERATIONS

Global nuclear energy deployment scenarios suggest favorable economics for smaller, more versatile, and self-contained reactor technologies. Recognizing their key features as integrated, autonomous and either semi-remotely operated or fully remotely operated systems, microreactors are expected to be deployed in large numbers servicing off/micro-grids, many in geographically remote locations. Integrated nature of these systems as well as ease of their transportation as complete units, simplified installation and relocation/decommissioning challenge traditional continuity-of-knowledge practices used for conventional light water reactors where refueling is done onsite at designated times only replacing portions of their cores and only after their full commissioning for operations including completion of their containment building with security and safeguards measures in place. This effort is exploring AI (artificial intelligence)-enabled monitoring options that would be design agnostic and would assure secure unit deployment and operations. The principle is to maintain situational awareness via real-time evaluations of simultaneous and remotely transmitted monitoring data capturing key safeguards attributes including such characteristics as temperature, radiation, vibrational signals (inter alia), and others. The key principle is to provide reliable and resilient security options while maintaining simplified and economical deployment. The paper will review feasible options for AI-enabled solutions for such evaluations.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Hydropower Black Start: A Guidebook for Retrofitting Grid Dependent Hydropower

Not all United States (US) hydropower plants were designed to provide black start, but they are increasingly needed to uphold resilience in the evolving electric grid. This guidance is designed to help understand the minimal retrofits required for grid dependent hydropower (GDH) plants behind the point of interconnection (POI). For distribution connected hydropower plants or those with dedicated cranking paths, such upgrades can be sufficient for the plant to provide black start. For others, more coordination with the transmission system operator will be needed. This guidebook answers a number of questions relevant to retrofitting hydropower plants with black start capabilities. For example, the guidebook answers: • How flexible do the wicket gate controls need to be? • Who needs to do hydro governor model validation, why, and how? • How robust and flexible do the excitation and AVR controls need to be? • What protection settings need to be adjusted? • What relay(s) will need to be bypassed or overridden and at what risk? • What is the electrical energy demand of the station load or auxiliary power systems? • What should the strategy to energize transformer(s) along cranking path to address inrush currents be? • How should the critical load restoration be sequenced? In addition to outlining the specifications that hydropower plants need to meet for each component to be able to perform black start, this guidebook provides a set of case studies for specific upgrades needed at actual plants. Between the case studies of plants that have already performed black start retrofits and the examples of how this guidebook can be applied to scope future retrofits, five key themes have been identified for retrofit needs. 1. Protection needs “black start” mode: hydropower plants that are not designed with black start capabilities will have protections that prevent them from interconnecting to a “dead bus.” These protections will need to be overridden in every retrofit case and a separate black start mode should be established so that operators can safely switch between black start and grid connected modes, minimizing the risk to the plant. 2. Wicket gates need modern controls: digital governors accelerate the parameter tuning process and gate position sensors improve controllability, so plants with mechanical governors should be upgraded. Furthermore, a black start and islanding mode should be established for controls to maximize plant performance. 3. Robust excitation support: the DC system or excitation generator needs to be reliable enough to form and sustain the rotor electromagnetic field. These systems are typically undersized in plants that were not designed for black start, so they will need to be upgraded. 4. Turbine-governor model validation and operator training: validation of a standard hydro governor model is needed to characterize the dynamic response (i.e., inertial and primary frequency response) of the GDH. This is required for control development and old hydropower plants often have outdated or incorrect models. Operator training is also typically required to ensure the hardware retrofits are utilized correctly during the black start process. 5. Transformer and cranking path energization: any upgradation and control adjustment in front of the POI will depend upon the existing interconnection. Coordination with the transmission or distribution operator may be required.

13 HYDRO ENERGY↗