An inventory of aeronautical ground research facilities. Volume 3: Structural

An inventory of test facilities for conducting acceleration, environmental, impact, structural shock, load, heat, vibration, and noise tests is presented. The facility is identified with a description of the equipment, the testing capabilities, and cost of operation. Performance data for the facility are presented in charts and tables.

Pirrello, C. J.↗

Qualification and Selection of Flight Diode Lasers for Space Applications

The reliability and lifetime of laser diodes is critical to space missions. The Nuclear Spectroscopic Telescope Array (NuSTAR) mission includes a metrology system that is based upon laser diodes. An operational test facility has been developed to qualify and select, by mission standards, laser diodes that will survive the intended space environment and mission lifetime. The facility is situated in an electrostatic discharge (ESD) certified clean-room and consist of an enclosed temperature-controlled stage that can accommodate up to 20 laser diodes. The facility is designed to characterize a single laser diode, in addition to conducting laser lifetime testing on up to 20 laser diodes simultaneously. A standard laser current driver is used to drive a single laser diode. Laser diode current, voltage, power, and wavelength are measured for each laser diode, and a method of selecting the most adequate laser diodes for space deployment is implemented. The method consists of creating histograms of laser threshold currents, powers at a designated current, and wavelengths at designated power. From these histograms, the laser diodes that illustrate a performance that is outside the normal are rejected and the remaining lasers are considered spaceborne candidates. To perform laser lifetime testing, the facility is equipped with 20 custom laser drivers that were designed and built by California Institute of Technology specifically to drive NuSTAR metrology lasers. The laser drivers can be operated in constant-current mode or alternating-current mode. Situated inside the enclosure, in front of the laser diodes, are 20 power-meter heads to record laser power throughout the duration of lifetime testing. Prior to connecting a laser diode to the current source for characterization and lifetime testing, a background program is initiated to collect current, voltage, and resistance. This backstage data collection enables the operational test facility to have full laser diode traceablity.

Liebe, Carl C.↗

Large Payload Transportation and Test Considerations

Ironically, the limiting factor to a national heavy lift strategy may not be the rocket technology needed to throw a heavy payload, but rather the terrestrial infrastructure - roads, bridges, airframes, and buildings - necessary to transport, acceptance test, and process large spacecraft. Failure to carefully consider how large spacecraft are designed, and where they are manufactured, tested, or launched, could result in unforeseen cost to modify/develop infrastructure, or incur additional risk due to increased handling or elimination of key verifications. During test and verification planning for the Altair project, a number of transportation and test issues related to the large payload diameter were identified. Although the entire Constellation Program - including Altair - was canceled in the 2011 NASA budget, issues identified by the Altair project serve as important lessons learned for future payloads that may be developed to support national "heavy lift" strategies. A feasibility study performed by the Constellation Ground Operations (CxGO) project found that neither the Altair Ascent nor Descent Stage would fit inside available transportation aircraft. Ground transportation of a payload this large over extended distances is generally not permitted by most states, so overland transportation alone would not have been an option. Limited ground transportation to the nearest waterway may be permitted, but water transportation could take as long as 66 days per production unit, depending on point of origin and acceptance test facility; transportation from the western United States would require transit through the Panama Canal to access the Kennedy Space Center launch site. Large payloads also pose acceptance test and ground processing challenges. Although propulsion, mechanical vibration, and reverberant acoustic test facilities at NASA s Plum Brook Station have been designed to accommodate large spacecraft, special handling and test work-arounds may be necessary, which could increase cost, schedule, and technical risk. Once at the launch site, there are no facilities currently capable of accommodating the combination of large payload size and hazardous processing (which includes hypergolic fuels, pyrotechnic devices, and high pressure gasses).

Rucker, Michelle A.↗

Advanced Measurement and Visualization Techniques for High-Temperature Heat Pipe Experiments

This report conducts a preliminary investigation of the available literature and summarizes some potential advanced measurement and visualization techniques for operating high-temperature heat pipe (HP) that can be implemented to support the United States (U.S.) Department of Energy (DOE) Microreactor Program (MRP). The primary objective for the extensive literature research is to investigate the possibilities and feasibility for the design and construction of an advanced experimental test facility with the aim of producing high-fidelity high-resolution heat pipe data during its operation. Based on the existing HP test facilities at Idaho National Laboratory (INL)—including the Single Primary Heat Extraction and Removal Emulator (SPHERE) and the Microreactor Agile Non-Nuclear Experimental Test Bed (MAGNET)—further efforts will be made to examine the technical feasibility to HP measurements and support the research, development, and demonstration (RD&D) process for an HP-cooled microreactor. Continuing collaborations with the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program, other research institutes and universities are considered to be extremely important so that the experimental facility and resultant database can satisfy the validation needs of advanced heat pipe modeling codes being developed under DOE NEAMS program.

42 ENGINEERING↗

Fuel Motion Monitoring System at TREAT – FY2017 Instrumentation Summary

This document is a report summarizing FY2017 efforts related to the Transient Reactor Test Facility (TREAT) Fuel Motion Monitoring System, "hodoscope," refurbishment campaign. TREAT is an air-cooled, graphite-moderated, heterogeneous test facility designed to evaluate reactor fuels and structural materials under conditions that simulate various types of transient overpower and under-cooling situations in a nuclear reactor. Fuel meltdowns, metal-water reactions, thermal interaction between overheated fuel and coolant, and the transient behavior of ceramic fuel for high-temperature systems can be studied. A key instrument that monitors fuel motion as these events take place is the fast neutron hodoscope. The hodoscope is designed to allow for pre-, during-, and post- transient imaging of fuel within a test loop in the center of the reactor core. The preferred technique for imaging is detection of fast neutrons produced by fission in the test fuel, travelling unmoderated through an empty row of core fuel assemblies and then through a multi-slot collimator to a 360-detector array. Due to the age of the instrument, a refurbishment of the hodoscope’s fast neutron detection capability is necessary to support real-time, fuel-position experimental data collection. One particular challenge in this regard is related to the refurbishment of the fast-neutron-sensing detector elements in the detector array. This report summarizes major activities and accomplishments related to the FMMS refurbishment in FY2017. Of particular note was work related to identifying options for new proton recoil scintillator wafer and initial examination of the TREAT proton recoil proportional counter detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Crash Tests of Protective Airplane Floors

Energy-absorbing floors reduce structural buckling and impact forces on occupants. 56-page report discusses crash tests of energy-absorbing aircraft floors. Describes test facility and procedures; airplanes, structural modifications, and seats; crash dynamics; floor and seat behavior; and responses of anthropometric dummies seated in airplanes. Also presents plots of accelerations, photographs and diagrams of test facility, and photographs and drawings of airplanes before, during, and after testing.

Carden, H. D.↗

Modeling Analysis for NASA GRC Vacuum Facility 5 Upgrade

A model of the VF5 test facility at NASA Glenn Research Center was developed using the direct simulation Monte Carlo Hypersonic Aerothermodynamics Particle (HAP) code. The model results were compared to several cold flow and thruster hot fire cases. The main uncertainty in the model is the determination of the effective sticking coefficient -- which sets the pumping effectiveness of the cryopanels and oil diffusion pumps including baffle transmission. An effective sticking coefficient of 0.25 was found to provide generally good agreement with the experimental chamber pressure data. The model, which assumes a cold diffuse inflow, also fared satisfactorily in predicting the pressure distribution during thruster operation. The model was used to assess other chamber configurations to improve the local effective pumping speed near the thruster. A new configuration of the existing cryopumps is found to show more than 2x improvement over the current baseline configuration.

cryopumping↗

Replacement of HCFC-225 Solvent for Cleaning NASA Propulsion Oxygen Systems

Since the 1990's, when the Class I Ozone Depleting Substance (ODS) chlorofluorocarbon‐113 (CFC‐113) was banned, NASA's propulsion test facilities at Marshall Space Flight Center (MSFC) and Stennis Space Center (SSC) have relied upon hydrochlorofluorocarbon‐225 (HCFC‐225) to safely clean and verify the cleanliness of large scale propulsion oxygen systems. Effective January 1, 2015, the production, import, export, and new use of HCFC‐225, a Class II ODS, was prohibited by the Clean Air Act. In 2012 through 2014, leveraging resources from both NASA and the Defense Logistics Agency ‐ Aviation Hazardous Minimization and Green Products Branch, test labs at MSFC, SSC, and Johnson Space Center's White Sands Test Facility (WSTF) collaborated to seek out, test, and qualify a replacement for HCFC‐225 that is both an effective cleaner and safe for use with oxygen systems. This presentation summarizes the tests performed, results, and lessons learned. It also demonstrates the benefits of cross‐agency collaboration in a time of limited resources.

Lowrey, Nikki M.↗

Determination of Scale Bar for AGHCF Metallography Data

The DOE Nuclear Energy Advanced Reactor Technologies (ART) Fast Reactor Program (FRP) has supported the development of several databases containing information on the safety performance of fast reactors, components, and fuels. This growing collection of legacy experimental data, operating data, and analysis is available online to registered users. Metallography data represents one of the most critical types of post-irradiation examination (PIE) data being collected, organized, and archived in several ART Fast Reactor Databases (https://frdb.ne.anl.gov), including the Metallic Fuels Irradiation & Physics Database (FIPD), Out-of-Pile Transient Database (OPTD), and TREAT (the Transient Reactor Test Facility) Experimental Relational Database (TREXR). These databases contain three principal sets of metallography data. The first set comprises metallography data from Experimental Breeder Reactor-II (EBR-II) and Fast Flux Test Facility (FFTF) irradiated fuel pins examined in the Hot Fuel Examination Facility (HFEF). The second set consists of metallography data from EBR-II irradiated fuel pins examined in the Alpha-Gamma Hot Cell Facility (AGHCF). The third set includes metallography data from transient-tested fuel pins (including both out-of-pile furnace tests and TREAT tests) examined in AGHCF. Since both the second and third sets were generated in AGHCF, they are governed by identical specifications. The metallography data in the databases consist of digital images scanned from either positive or negative photographic films. To analyze the microstructure of a fuel pin, a series of preparatory steps are required, including sectioning, epoxy mounting, mechanical grinding and polishing, and etching. Following sample preparation, specimens are transferred for metallographic examination. The AGHCF and HFEF metallography data were generated using optical microscopes manufactured by Leitz and Bausch and Lomb (B&L). Images were recorded on Polaroid film at preset magnifications. Magnification verification for the Leitz and B&L metallographs was conducted every two months prior to 1989 and at least every six months from 1989 through the conclusion of the IFR program. Magnifications determined from imaging of microslide standards were compared to the instrument settings for magnifications ranging from 50× to 500×. If the magnifications determined from standards deviated from the instrument settings, adjustments were made to the bellows extension until agreement was achieved. The specifications for AGHCF and HFEF legacy metallography data have been established based on available hard-copy and digital records, most of which have been incorporated into the data repositories associated with FIPD, OPTD, and TREXR. Detailed specifications including hard-copy records, digitized records, cutting diagrams and sectioning schemes, high-magnification photographs, photomosaics (composites), information tags, scale bars, and magnification verification procedures can be found in a separate report.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Irradiation dose and temperature dependence of fracture toughness in high dose HT9 steel from the fuel duct of FFTF

To expand the knowledge base for fast reactor core materials, fracture toughness has been evaluated for high dose HT9 steel using miniature disk compact tension (DCT) specimens. The HT9 steel DCT specimens were machined from the ACO-3 fuel duct of the Fast Flux Test Facility (FFTF), which achieved high doses in the range of 3–148 dpa at 378–504 C. The static fracture resistance (J-R) tests have been performed in a servohydraulic testing machine in vacuum at selected temperatures including room temperature, 200 C, and each irradiation temperature. Brittle fracture with a low toughness less than 50 MPa pm occurred in room temperature tests when irradiation temperature was below 400 C, while ductile fracture with stable crack growth was observed when irradiation temperature was higher. No fracture toughness less than 100 MPa pm was measured when the irradiation temperature was above 430 C. It was shown that the influence of irradiation temperature was dominant in fracture toughness while the irradiation dose has only limited influence over the wide dose range 3–148 dpa. A slow decrease of fracture toughness with test temperature above room temperature was observed for the nonirradiated and high temperature (>430 *C) irradiation cases, which indicates that the ductile–brittle transition temperatures (DBTTs) in those conditions are lower than room temperature. A comparison with the collection of existing data confirmed the dominance of irradiation temperature in the fracture toughness of HT9 steels.

Byun, Thak Sang↗

A3 Subscale Rocket Hot Fire Testing

This paper gives a description of the methodology and results of J2-X Subscale Simulator (JSS) hot fire testing supporting the A3 Subscale Diffuser Test (SDT) project at the E3 test facility at Stennis Space Center, MS (SSC). The A3 subscale diffuser is a geometrically accurate scale model of the A3 altitude simulating rocket test facility. This paper focuses on the methods used to operate the facility and obtain the data to support the aerodynamic verification of the A3 rocket diffuser design and experimental data quantifying the heat flux throughout the facility. The JSS was operated at both 80% and 100% power levels and at gimbal angle from 0 to 7 degrees to verify the simulated altitude produced by the rocket-rocket diffuser combination. This was done with various secondary GN purge loads to quantify the pumping performance of the rocket diffuser. Also, special tests were conducted to obtain detailed heat flux measurements in the rocket diffuser at various gimbal angles and in the facility elbow where the flow turns from vertical to horizontal upstream of the 2nd stage steam ejector.

Saunders, G. P.↗

Specifications of Legacy U(Pu)Zr Metallography Data

The DOE Nuclear Energy Advanced Reactor Technologies (ART) Program has supported the creation of several databases with information describing the safety performance of fast reactors, components, and fuels. This growing collection of legacy experimental data, operating data, and analysis is available online to registered users. Metallography data is one of the most important types of PIE data being collected, organized and stored in several ART Fast Reactor Databases (https://frdb.ne.anl.gov), including the Fuels Irradiation & Physics Database (FIPD), Out-of-Pile Transient Database (OPTD), and TREAT (the Transient Reactor Test Facility) Experimental Relational Database (TREXR). These databases contain three main sets of metallography data. The first set is the metallography data from Experimental Breeder Reactor-II (EBR-II) and Fast Flux Test Facility (FFTF) irradiated fuel pins measured in the Hot Fuel Examination Facility (HFEF); the second set is the metallography data from EBR-II irradiated fuel pins measured in the Alpha-Gamma Hot Cell Facility (AGHCF); the third set is the metallography data from transient tested fuel pins (the transients tests include the out-of-pile tests and TREAT tests) measured in AGHCF. Since both the second and third sets of data were measured in AGHCF, they are governed by the same specification. The metallography data in the databases are digital images scanned from either positive or negative photos. The quality of the images, including their resolution and contrast, relies on the preserved quality of the pictures and the scanning conditions. To analyze the microstructure of a fuel pin, a series of preparatory steps must be undertaken. These include sectioning, epoxy mounting, mechanical grinding and polishing, and often etching. The resulting samples were then transferred to a secondary hot cell, or glovebox (depending the strength of radiation field) for microscopy examination. The specifications provided herein focus on the metallography examinations. The sample grinding, polishing and etching processes are also discussed. The procedures involving sectioning and epoxy mounting are out of the scope of the current specification; details can be found in the corresponding operation manuals. If more data are collected and added to the ART Fast Reactor Databases, this specification will be updated to accommodate the additional data.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Real-Time Health Monitoring for Gas Turbine Components Using Online Learning and High-Dimensional Data

Capital-intensive turbomachinery, such as gas turbines and combined cycle plants, are constantly being monitored for performance anomalies, faults, and physical degradation. Although these power-generating assets are equipped with hundreds of sensors, existing monitoring tools can only handle moderate-sized data. As a result, only a handful of aggregate metrics are used to monitor machine health. At the same time, developing advanced tools suitable for large datasets have been restricted by the lack of appropriate data. The objective of this proposal was to demonstrate a Big Data analytics framework for fault detection and diagnosis in gas turbine applications. We develop a predictive analytics framework methodology guided by these experimental data, industrial data from our collaborators, and physics-based models with engineering domain knowledge. Our analytics framework consists of four key components (1) a data curation process that addresses data storage, data quality assessments, and integrity checks, (2) a feature engineering component that utilizes statistical methods and transformation algorithms guided by physics-based models to extract high-fidelity fault features that can be leveraged for fault detection and classifying fault severities, (3) a Machine Learning-based fault detection and diagnostics algorithms for detecting operational and hardware faults in the combustion and the turbines section. We utilize two industry-class gas turbine component test rigs to generate first of its kind data for critical gas turbine faults with varying severity levels. Advanced gas turbine test facilities will be interrogated using state-of-the-art instrumentation techniques to build fault signatures and data trends for key combustor and turbine faults. Data generated from a combustor test rig (Georgia Tech) and a turbine test rig (Penn State) during both normal operation and with seeded faults serve as the basis for the Big Data sets. The test conditions in the two test facilities include common, critical events that occur in the operation. Utilizing the combustor test rig, we examine two common combustor faults: lean blowout and centerbody degradation. For the turbine section we develop analytic models for monitoring cooling faults in the gas turbine

03 NATURAL GAS↗

Real-Time Health Monitoring for Gas Turbine Components Using Online Learning and High-Dimensional Data (Final Report)

Capital-intensive turbomachinery, such as gas turbines and combined cycle plants, are constantly being monitored for performance anomalies, faults, and physical degradation. Although these power-generating assets are equipped with hundreds of sensors, existing monitoring tools can only handle moderate-sized data. As a result, only a handful of aggregate metrics are used to monitor machine health. At the same time, developing advanced tools suitable for large datasets have been restricted by the lack of appropriate data. The objective of this proposal was to demonstrate a Big Data analytics framework for fault detection and diagnosis in gas turbine applications. We develop a predictive analytics framework methodology guided by these experimental data, industrial data from our collaborators, and physics-based models with engineering domain knowledge. Our analytics framework consists of four key components: (1) a data curation process that addresses data storage, data quality assessments, and integrity checks, (2) a feature engineering component that utilizes statistical methods and transformation algorithms guided by physics-based models to extract high-fidelity fault features that can be leveraged for fault detection and classifying fault severities, (3) a Machine Learning-based fault detection and diagnostics algorithms for detecting operational and hardware faults in the combustion and the turbines section. We utilize two industry-class gas turbine component test rigs to generate first of its kind data for critical gas turbine faults with varying severity levels. Advanced gas turbine test facilities will be interrogated using state-of-the-art instrumentation techniques to build fault signatures and data trends for key combustor and turbine faults. Data generated from a combustor test rig (Georgia Tech) and a turbine test rig (Penn State) during both normal operation and with seeded faults serve as the basis for the Big Data sets. The test conditions in the two test facilities include common, critical events that occur in the operation. Utilizing the combustor test rig, we examine two common combustor faults: lean blowout and centerbody degradation. For the turbine section we develop analytic models for monitoring cooling faults in the gas turbine.

20 FOSSIL-FUELED POWER PLANTS↗

Results of the Test Program for Replacement of AK-225G Solvent for Cleaning NASA Propulsion Oxygen Systems

Since the 1990's, when the Class I Ozone Depleting Substance (ODS) chlorofluorocarbon-113 (CFC-113) was banned, NASA's propulsion test facilities at Marshall Space Flight Center (MSFC) and Stennis Space Center (SSC) have relied upon the solvent AsahiKlin AK-225 (hydrochlorofluorocarbon-225ca/cb or HCFC-225ca/cb) and, more recently AK-225G (the single isomer form, HCFC-225cb) to safely clean and verify the cleanliness of large scale propulsion oxygen systems. Effective January 1, 2015, the production, import, export, and new use of Class II Ozone Depleting Substances, including AK-225G, was prohibited in the United States by the Clean Air Act. In 2012 through 2014, NASA test labs at MSFC, SSC, and Johnson Space Center's White Sands Test Facility (WSTF) collaborated to seek out, test, and qualify a solvent replacement for AK-225G that is both an effective cleaner and safe for use with oxygen systems. This paper summarizes the tests performed, results, and lessons learned.

Lowrey, Nikki M.↗

ACCELERATING MICROREACTOR DEVELOPMENT AND DEPLOYMENT THROUGH JOINT PUBLIC TEST BEDS AND PRIVATE ADVANCED REACTOR DEVELOPMENT

The United States Department of Energy (DOE) has funded the National Reactor Innovation Center (NRIC) to accelerate the development and commercialization of small modular reactors and other advanced reactor technologies. As part of this effort NIRC is building two strategic assets at the Idaho National Laboratory (INL) to facilitate public-private partnerships for the development and testing of advanced nuclear microreactors and Small Modular Reactors (SMR). One will provide a safe, secure, and affordable location for High-Assay Low Enriched Uranium (HALEU) fueled reactors and a second for Highly Enriched Uranium (HEU) fueled reactors. Together these testbeds fill a nuclear testing infrastructure gap. The availability of such comprehensive testing facilities at the national labs eliminates the significant financial and operational burdens associated with each developer building and licensing their own test facilities. Consequently, this approach will not only accelerate technological innovation and reduce time-to-market for advanced nuclear solutions but it also underscores the DOE's commitment to fostering an ecosystem where nuclear energy will thrive as a clean, reliable, and efficient source of power. The Demonstration of Microreactor Experiments (DOME) and Laboratory for Operations and Testing in the United States (LOTUS) have planned availability in 2026, and 2027 respectively.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Fermilab’s horizontal test stand upgrade overview and commissioning

Cryo-assemblies with the low-beta Nb3Sn quadrupoles for the High Luminosity LHC (HL-LHC) upgrade will be tested at Fermilab’s magnet test facility. Total of 10 cryo-assemblies will be delivered to CERN within the US HL-LHC Accelerator Upgrade Project (AUP). The horizontal test stand at Fermilab already has been used for testing the existing LHC inner-triplet quadrupoles, but the stand and corresponding electrical and cryogenic sub-systems were not operational more than a decade. In order to restore the test stand functions and meet the design and test requirements for the high luminosity LHC magnets, the existing horizontal test facility at Fermilab underwent a significant refurbishment of the cryogenic and mechanical components. Most of the upgrades were completed and verified during so called zero-magnet test by late 2020, and then final commissioning of the upgraded test stand was completed during the first cryo-assembly test in 2023. These tests verified all the cryo-mechanical installations, as well as the test stand operations, including controlled cooldown and operation at 1.9 K, the helium recovery capabilities, magnet protection and process controls.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

UK-4 prototype spacecraft magnetic tests

The spacecraft was tested in a magnetic test facility which uses a 42 ft. diameter coil system to produce a controlled magnetic field of high uniformity over a large central volume. The primary objectives of the tests were: (1) to determine the permanent, induced, and stray magnetic moments of the spacecraft and to assess its magnetic stability; (2) to evaluate the magnetorquer coil system; and (3) to deperm, compensate, and make other adjustments necessary to achieve satisfactory magnetic characteristics for the spacecraft. The test facility and procedures are described together with the results obtained. In addition, the problems encountered during the tests and the significance of the test findings are discussed.

Pruett, W. E.↗