Search NASA⌕ Search

SEARCH · Search NASA

Results for “methods - statistical”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Investigation of various energy deposition kernel refinements for the convolution/superposition method

Purpose: Several simplifications used in clinical implementations of the convolution/superposition (C/S) method, specifically, density scaling of water kernels for heterogeneous media and use of a single polyenergetic kernel, lead to dose calculation inaccuracies. Although these weaknesses of the C/S method are known, it is not well known which of these simplifications has the largest effect on dose calculation accuracy in clinical situations. The purpose of this study was to generate and characterize high-resolution, polyenergetic, and material-specific energy deposition kernels (EDKs), as well as to investigate the dosimetric impact of implementing spatially variant polyenergetic and material-specific kernels in a collapsed cone C/S algorithm.Methods: High-resolution, monoenergetic water EDKs and various material-specific EDKs were simulated using the EGSnrc Monte Carlo code. Polyenergetic kernels, reflecting the primary spectrum of a clinical 6 MV photon beam at different locations in a water phantom, were calculated for different depths, field sizes, and off-axis distances. To investigate the dosimetric impact of implementing spatially variant polyenergetic kernels, depth dose curves in water were calculated using two different implementations of the collapsed cone C/S method. The first method uses a single polyenergetic kernel, while the second method fully takes into account spectral changes in the convolution calculation. To investigate the dosimetric impact of implementing material-specific kernels, depth dose curves were calculated for a simplified titanium implant geometry using both a traditional C/S implementation that performs density scaling of water kernels and a novel implementation using material-specific kernels.Results: For our high-resolution kernels, we found good agreement with the Mackie et al. kernels, with some differences near the interaction site for low photon energies (<500 keV). For our spatially variant polyenergetic kernels, we found that depth was the most dominant factor affecting the pattern of energy deposition; however, the effects of field size and off-axis distance were not negligible. For the material-specific kernels, we found that as the density of the material increased, more energy was deposited laterally by charged particles, as opposed to in the forward direction. Thus, density scaling of water kernels becomes a worse approximation as the density and the effective atomic number of the material differ more from water. Implementation of spatially variant, polyenergetic kernels increased the percent depth dose value at 25 cm depth by 2.1%–5.8% depending on the field size, while implementation of titanium kernels gave 4.9% higher dose upstream of the metal cavity (i.e., higher backscatter dose) and 8.2% lower dose downstream of the cavity.Conclusions: Of the various kernel refinements investigated, inclusion of depth-dependent and metal-specific kernels into the C/S method has the greatest potential to improve dose calculation accuracy. Implementation of spatially variant polyenergetic kernels resulted in a harder depth dose curve and thus has the potential to affect beam modeling parameters obtained in the commissioning process. For metal implants, the C/S algorithms generally underestimate the dose upstream and overestimate the dose downstream of the implant. Implementation of a metal-specific kernel mitigated both of these errors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TH-E-18A-01: Developments in Monte Carlo Methods for Medical Imaging

Monte Carlo simulation methods are widely used in medical physics research and are starting to be implemented in clinical applications such as radiation therapy planning systems. Monte Carlo simulations offer the capability to accurately estimate quantities of interest that are challenging to measure experimentally while taking into account the realistic anatomy of an individual patient. Traditionally, practical application of Monte Carlo simulation codes in diagnostic imaging was limited by the need for large computational resources or long execution times. However, recent advancements in high-performance computing hardware, combined with a new generation of Monte Carlo simulation algorithms and novel postprocessing methods, are allowing for the computation of relevant imaging parameters of interest such as patient organ doses and scatter-to-primaryratios in radiographic projections in just a few seconds using affordable computational resources. Programmable Graphics Processing Units (GPUs), for example, provide a convenient, affordable platform for parallelized Monte Carlo executions that yield simulation times on the order of 10{sup 7} xray/ s. Even with GPU acceleration, however, Monte Carlo simulation times can be prohibitive for routine clinical practice. To reduce simulation times further, variance reduction techniques can be used to alter the probabilistic models underlying the x-ray tracking process, resulting in lower variance in the results without biasing the estimates. Other complementary strategies for further reductions in computation time are denoising of the Monte Carlo estimates and estimating (scoring) the quantity of interest at a sparse set of sampling locations (e.g. at a small number of detector pixels in a scatter simulation) followed by interpolation. Beyond reduction of the computational resources required for performing Monte Carlo simulations in medical imaging, the use of accurate representations of patient anatomy is crucial to the virtual generation of medical images and accurate estimation of radiation dose and other imaging parameters. For this, detailed computational phantoms of the patient anatomy must be utilized and implemented within the radiation transport code. Computational phantoms presently come in one of three format types, and in one of four morphometric categories. Format types include stylized (mathematical equation-based), voxel (segmented CT/MR images), and hybrid (NURBS and polygon mesh surfaces). Morphometric categories include reference (small library of phantoms by age at 50th height/weight percentile), patient-dependent (larger library of phantoms at various combinations of height/weight percentiles), patient-sculpted (phantoms altered to match the patient's unique outer body contour), and finally, patient-specific (an exact representation of the patient with respect to both body contour and internal anatomy). The existence and availability of these phantoms represents a very important advance for the simulation of realistic medical imaging applications using Monte Carlo methods. New Monte Carlo simulation codes need to be thoroughly validated before they can be used to perform novel research. Ideally, the validation process would involve comparison of results with those of an experimental measurement, but accurate replication of experimental conditions can be very challenging. It is very common to validate new Monte Carlo simulations by replicating previously published simulation results of similar experiments. This process, however, is commonly problematic due to the lack of sufficient information in the published reports of previous work so as to be able to replicate the simulation in detail. To aid in this process, the AAPM Task Group 195 prepared a report in which six different imaging research experiments commonly performed using Monte Carlo simulations are described and their results provided. The simulation conditions of all six cases are provided in full detail, with all necessary data on material composition, source, geometry, scoring and other parameters provided. The results of these simulations when performed with the four most common publicly available Monte Carlo packages are also provided in tabular form. The Task Group 195 Report will be useful for researchers needing to validate their Monte Carlo work, and for trainees needing to learn Monte Carlo simulation methods. In this symposium we will review the recent advancements in highperformance computing hardware enabling the reduction in computational resources needed for Monte Carlo simulations in medical imaging. We will review variance reduction techniques commonly applied in Monte Carlo simulations of medical imaging systems and present implementation strategies for efficient combination of these techniques with GPU acceleration. Trade-offs involved in Monte Carlo acceleration by means of denoising and “sparse sampling” will be discussed. A method for rapid scatter correction in cone-beam CT (<5 min/scan) will be presented as an illustration of the simulation speeds achievable with optimized Monte Carlo simulations. We will also discuss the development, availability, and capability of the various combinations of computational phantoms for Monte Carlo simulation of medical imaging systems. Finally, we will review some examples of experimental validation of Monte Carlo simulations and will present the AAPM Task Group 195 Report. Learning Objectives: Describe the advances in hardware available for performing Monte Carlo simulations in high performance computing environments. Explain variance reduction, denoising and sparse sampling techniques available for reduction of computational time needed for Monte Carlo simulations of medical imaging. List and compare the computational anthropomorphic phantoms currently available for more accurate assessment of medical imaging parameters in Monte Carlo simulations. Describe experimental methods used for validation of Monte Carlo simulations in medical imaging. Describe the AAPM Task Group 195 Report and its use for validation and teaching of Monte Carlo simulations in medical imaging.

60 APPLIED LIFE SCIENCES↗

WE-G-207-07: Iterative CT Shading Correction Method with No Prior Information

Purpose: Shading artifacts are caused by scatter contamination, beam hardening effects and other non-ideal imaging condition. Our Purpose is to propose a novel and general correction framework to eliminate low-frequency shading artifacts in CT imaging (e.g., cone-beam CT, low-kVp CT) without relying on prior information. Methods: Our method applies general knowledge of the relatively uniform CT number distribution in one tissue component. Image segmentation is applied to construct template image where each structure is filled with the same CT number of that specific tissue. By subtracting the ideal template from CT image, the residual from various error sources are generated. Since the forward projection is an integration process, the non-continuous low-frequency shading artifacts in the image become continuous and low-frequency signals in the line integral. Residual image is thus forward projected and its line integral is filtered using Savitzky-Golay filter to estimate the error. A compensation map is reconstructed on the error using standard FDK algorithm and added to the original image to obtain the shading corrected one. Since the segmentation is not accurate on shaded CT image, the proposed scheme is iterated until the variation of residual image is minimized. Results: The proposed method is evaluated on a Catphan600 phantom, a pelvic patient and a CT angiography scan for carotid artery assessment. Compared to the one without correction, our method reduces the overall CT number error from >200 HU to be <35 HU and increases the spatial uniformity by a factor of 1.4. Conclusion: We propose an effective iterative algorithm for shading correction in CT imaging. Being different from existing algorithms, our method is only assisted by general anatomical and physical information in CT imaging without relying on prior knowledge. Our method is thus practical and attractive as a general solution to CT shading correction. This work is supported by the National Science Foundation of China (NSFC Grant No. 81201091), National High Technology Research and Development Program of China (863 program, Grant No. 2015AA020917), and Fund Project for Excellent Abroad Scholar Personnel in Science and Technology.

60 APPLIED LIFE SCIENCES↗

SU-G-201-05: Comparison of Different Methods for Output Verification of Eleckta Nucletron’s Valencia Skin Applicators

Purpose: The provided output factors for Elekta Nucletron’s skin applicators are based on Monte Carlo simulations. These outputs have not been independently verified, and there is no recognized method for output verification of the vendor’s applicators. The purpose of this work is to validate the outputs provided by the vendor experimentally. Methods: Using a Flexitron Ir-192 HDR unit, three experimental methods were employed to determine dose with the 30 mm diameter Valencia applicator: first a gradient method using extrapolation ionization chamber (Far West Technology, EIC-1) measurements in solid water phantom at 3 mm SCD was used. The dose was derived based on first principles. Secondly a combination of a parallel plate chamber (Exradin A-10) and the EIC-1 was used to determine air kerma at 3 mm SCD. The air kerma was converted to dose to water in line with TG-61 formalism by using a muen ratio and a scatter factor measured with the skin applicators. Similarly a combination of the A-10 parallel plate chamber and gafchromic film (EBT 3) was also used. The Nk factor for the A-10 chamber was obtained through linear interpolation between ADCL supplied Nk factors for Cs-137 and M250. Results: EIC-1 measurements in solid water defined the outputs factor at 3 mm as 0.1343 cGy/U hr. The combination of A-10/ EIC-1 and A-10/EBT3 lead to output factors of 0.1383 and 0.1568 cGy/U hr, respectively. For comparison the output recommended by the vendor is 0.1659 cGy/U hr. Conclusion: All determined dose rates were lower than the vendor supplied values. The observed discrepancy between extrapolation chamber and film methods can be ascribed to extracameral gradient effects that may not be fully accounted for by the former method.

60 APPLIED LIFE SCIENCES↗

Patient-specific quantification of image quality: An automated method for measuring spatial resolution in clinical CT images

Purpose: To develop and validate an automated technique for evaluating the spatial resolution characteristics of clinical computed tomography (CT) images. Methods: Twenty one chest and abdominopelvic clinical CT datasets were examined in this study. An algorithm was developed to extract a CT resolution index (RI) analogous to the modulation transfer function from clinical CT images by measuring the edge-spread function (ESF) across the patient’s skin. A polygon mesh of the air-skin boundary was created. The faces of the mesh were then used to measure the ESF across the air-skin interface. The ESF was differentiated to obtain the line-spread function (LSF), and the LSF was Fourier transformed to obtain the RI. The algorithm’s ability to detect the radial dependence of the RI was investigated. RIs measured with the proposed method were compared with a conventional phantom-based method across two reconstruction algorithms (FBP and iterative) using the spatial frequency at 50% RI, f{sub 50}, as the metric for comparison. Three reconstruction kernels were investigated for each reconstruction algorithm. Finally, an observer study was conducted to determine if observers could visually perceive the differences in the measured blurriness of images reconstructed with a given reconstruction method. Results: RI measurements performed with the proposed technique exhibited the expected dependencies on the image reconstruction. The measured f{sub 50} values increased with harder kernels for both FBP and iterative reconstruction. Furthermore, the proposed algorithm was able to detect the radial dependence of the RI. Patient-specific measurements of the RI were comparable to the phantom-based technique, but the patient data exhibited a large spread in the measured f{sub 50}, indicating that some datasets were blurrier than others even when the projection data were reconstructed with the same reconstruction algorithm and kernel. Results from the observer study substantiated this finding. Conclusions: Clinically informed, patient-specific spatial resolution can be measured from clinical datasets. The method is sufficiently sensitive to reflect changes in spatial resolution due to different reconstruction parameters. The method can be applied to automatically assess the spatial resolution of patient images and quantify dependencies that may not be captured in phantom data.

60 APPLIED LIFE SCIENCES↗

A 4 th -Order Particle-in-Cell Method with Phase-Space Remapping for the Vlasov&ndash;Poisson Equation

Numerical solutions to the Vlasov-Poisson system of equations have important applications to both plasma physics and cosmology. In this paper, we present a new particle-in- cell (PIC) method for solving this system that is 4th-order accurate in both space and time. Our method is a high-order extension of one presented previously [B. Wang, G. H. Miller, and P. Colella, SIAM J. Sci. Comput. , 33 (2011), pp. 3509-3537]. It treats all of the stages of the standard PIC update|charge deposition, force interpolation, the field solve, and the particle push|with 4th-order accuracy, and includes a 6th-order accurate phase-space remapping step for controlling particle noise. Here, we demonstrate the convergence of our method on a series of one- and two- dimensional electrostatic plasma test problems, comparing its accuracy to that of a 2 nd -order method. As expected, the 4 th -order method can achieve accuracy comparable to that of the 2nd-order method and with considerably fewer resolution elements.

97 MATHEMATICS AND COMPUTING↗

An Efficient, Globally Convergent Method for Optimization Under Uncertainty Using Adaptive Model Reduction and Sparse Grids

We present a new approach to efficiently solve optimization problems constrained by partial differential equations (PDEs) with uncertain coefficients. The method leverages two sources of inexactness that trade accuracy for speed: (1) stochastic collocation based on dimension-adaptive sparse grids (SGs), which approximates the stochastic objective function with a limited number of quadrature nodes, and (2) projection-based reduced-order models (ROMs), which generate efficient approximations to PDE solutions. These two sources of inexactness lead to inexact objective function and gradient evaluations, which are managed by a trust-region method that guarantees global convergence by adaptively refining the SG and ROM until a proposed error indicator drops below a tolerance specified by trust-region convergence theory. A key feature of the proposed method is that the error indicator---which accounts for errors incurred by both the SG and ROM---must be only an asymptotic error bound, i.e., a bound that holds up to an arbitrary constant that need not be computed. This allows the approach to be applicable to a wide range of problems, including those where sharp, computable error bounds are not available; this distinguishes the proposed method from previous works. Numerical experiments performed on a model problem from optimal flow control under uncertainty verify global convergence of the method and demonstrate the method's ability to outperform previously proposed alternatives.

97 MATHEMATICS AND COMPUTING↗

Additive Polynomial Time Integrators, Part I: Framework and Fully Implicit-Explicit Collocation Methods

In this paper we generalize the polynomial time integration framework to additively partitioned initial value problems. The framework we present is general and enables the construction of many new families of additive integrators with arbitrary order-of-accuracy and varying degree of implicitness. In this first work, we focus on a new class of implicit-explicit polynomial block methods that are based on fully implicit Runge–Kutta methods with Radau nodes and that possess high stage order. Here, we show that the new fully implicit-explicit (FIMEX) integrators have improved stability compared to existing IMEX Runge–Kutta methods, while also being more computationally efficient due to recent developments in preconditioning techniques for solving the associated systems of nonlinear equations. For PDEs on periodic domains where the implicit component is trivial to invert, we will show how parallelization of the right-hand side evaluations can be exploited to obtain significant speedup compared to existing serial IMEX Runge–Kutta methods. For parallel (in space) finite element discretizations, the new methods can achieve orders of magnitude better accuracy than existing IMEX Runge–Kutta methods and/or achieve a given accuracy several times times faster in terms of computational runtime.

97 MATHEMATICS AND COMPUTING↗

A Group Contribution Method for Estimating Cetane and Octane Numbers

Much of the research on advanced biofuels is devoted to the study of novel chemical pathways for converting nonfood biomass into liquid fuels that can be blended with existing transportation fuels. Many compounds under consideration are not found in the existing fuel supplies. Often, the physical properties needed to assess the viability of a potential biofuel are not available. The only reliable information available may be the molecular structure. Group contribution methods for estimating physical properties from molecular structure have been used for more than 60 years. The most common application is estimation of thermodynamic properties. More recently, group contribution methods have been developed for estimating rate dependent properties including cetane and octane numbers. Often, published group contribution methods are limited in terms of types of function groups and range of applicability. In this study, a new, broadly-applicable group contribution method based on an artificial neural network was developed to estimate cetane number research octane number, and motor octane numbers of hydrocarbons and oxygenated hydrocarbons. The new method is more accurate over a greater range molecular weights and structural complexity than existing group contribution methods for estimating cetane and octane numbers.

09 BIOMASS FUELS↗

Integrated Data Collection Analysis (IDCA) Program - SSST Testing Methods

The Integrated Data Collection Analysis (IDCA) program is conducting a proficiency study for Small- Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are the methods used for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis during the IDCA program. These methods changed throughout the Proficiency Test and the reasons for these changes are documented in this report. The most significant modifications in standard testing methods are: 1) including one specified sandpaper in impact testing among all the participants, 2) diversifying liquid test methods for selected participants, and 3) including sealed sample holders for thermal testing by at least one participant. This effort, funded by the Department of Homeland Security (DHS), is putting the issues of safe handling of these materials in perspective with standard military explosives. The study is adding SSST testing results for a broad suite of different HMEs to the literature. Ultimately the study will suggest new guidelines and methods and possibly establish the SSST testing accuracies needed to develop safe handling practices for HMEs. Each participating testing laboratory uses identical test materials and preparation methods wherever possible. The testing performers involved are Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Indian Head Division, Naval Surface Warfare Center, (NSWC IHD), Sandia National Laboratories (SNL), and Air Force Research Laboratory (AFRL/RXQL). These tests are conducted as a proficiency study in order to establish some consistency in test protocols, procedures, and experiments and to compare results when these testing variables cannot be made consistent.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Linearly Scaling 3D Fragment Method for Large Scale Electronic Structure Calculations

The Linearly Scaling three-dimensional fragment (LS3DF) method is an O(N) ab initio electronic structure method for large-scale nano material simulations. It is a divide-and-conquer approach with a novel patching scheme that effectively cancels out the artificial boundary effects, which exist in all divide-and-conquer schemes. This method has made ab initio simulations of thousand-atom nanosystems feasible in a couple of hours, while retaining essentially the same accuracy as the direct calculation methods. The LS3DF method won the 2008 ACM Gordon Bell Prize for algorithm innovation. Our code has reached 442 Tflop/s running on 147,456 processors on the Cray XT5 (Jaguar) at OLCF, and has been run on 163,840 processors on the Blue Gene/P (Intrepid) at ALCF, and has been applied to a system containing 36,000 atoms. In this paper, we will present the recent parallel performance results of this code, and will apply the method to asymmetric CdSe/CdS core/shell nanorods, which have potential applications in electronic devices and solar cells.

97 MATHEMATICS AND COMPUTING↗

Direct Vlasov solvers with high-order spectral element method.

This paper presents the development of parallel direct Vlasov solvers using the Spectral Element Method (SEM). Instead of the standard Particle-In-Cell (PIC) approach for kinetic space plasma simulation, i.e. solving the Vlasov-Maxwell equations, the direct method has been used in this paper. There are several benefits to solve the Vlasov equation directly, such as avoiding noise associated with the finite number of particles and the capability to capture the fine structure in the plasma, etc. The most challenging part of direct Vlasov solver comes from high dimension, as the computational cost increases as N{sup 2d}, where d is the dimension of the physical space. Recently due to fast development of supercomputers, the possibility of high dimensions becomes more realistic. A significant effort has been devoted to solve the Vlasov equation in low dimensions so far, now more interests focus on higher dimensions. Different numerical methods have been tried so far, such as finite difference method, Fourier spectral method, finite volume method, etc. In this paper SEM has been successfully applied to construct these solvers. SEM has shown several advantages, such as easy interpolation due to local element structure and long time integration due to its high order accuracy. Domain decomposition in high dimensions have been used for parallelization, these include scalable parallel 1D and 2D Poisson solvers. Benchmark results have been shown and simulation results have been reported for two different cases: one dimension (1P1V), and two dimensions (2P2V) in both physical and velocity spaces.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Verification Suite for the Application of the Limiting Surface Density Method to Arrays of 9975 Packages

Criticality Safety Engineering at the Savannah River Site’s K-Area Complex seeks to reduce the computational burden of analysis for the K-Area Complex. By applying an adapted Limiting Surface Density hand calculation method, the need for lengthy detailed Monte Carlo models of the storage arrays may be reduced or eliminated. After promising initial results using models of idealized but heterogeneous packages, application of the method to large arrays of highly heterogeneous 9975 shipping packages is attempted. A SCALE KENO-VI model of the 9975 package, with true dimensions and radial and axial heterogeneity is developed. A suite of array arrangements representing both arrays with equal number of packages per side (package-cubic) and arrays with unequal number of packages per side (non-cubic) are evaluated in SCALE. The cubic arrangements are used to derive the 9975-specific material and geometry constants for the LSD method. These constants are then used to implement the LSD method and compare the LSD- predicted critical mass per package to SCALE-predicted critical mass per package. Sensitivities to certain material and geometric nuances are evaluated for inclusion in the verification suite. Finally, the ability of the method to predict neutron multiplication changes induced by fissile mass changes is examined as a segue for evaluating credible abnormal conditions with the LSD method.

42 ENGINEERING↗

A FLEXIBLE NONLINEAR DIFFUSION ACCELERATION METHOD FOR THE FIRST ORDER EIGENVALUE SN EQUATIONS DISCRETIZED WITH DISCONTINUOUS FEM

This work describes a Nonlinear Diffusion Acceleration (NDA) method for the first order SN equations that discretizes both the transport equation and the associated diffusion system using discontinuous finite elements; the diffusion system is solved on a potentially coarser mesh and with a coarser energy group structure than the SN equations. The developed method differs from current methods by allowing the SN and diffusion system to be discretized with arbitrary FEM bases and by using an additive update of the SN system. The benefit of this capability is extension of the stability region to optically thicker mesh cells and stability without the necessity to underrelax the iterative algorithm. The presented method introduces the notion of consistency of the SN and diffusion solutions and derives suitable definitions of the cross sections, drift vectors, and element face closures. The NDA equations are solved using a Picard iteration scheme. Numerical results are presented for the C5G7 benchmark problem highlighting the effectiveness of the methods when deployed with the diffusion system discretized on the same mesh as the SN system. Additional results are presented for cases where the diffusion system features a coarser mesh, coarser energy group structure, or both, demonstrating its stability and effectiveness in these cases. It is observed that the effectiveness of the NDA method reduces when reducing the resolution of the associated diffusion system.

97 MATHEMATICS AND COMPUTING↗

A Monte Carlo implementation of the predictor-corrector Quasi-Static method

The Quasi-Static method (QS) is a useful tool for solving reactor transients since it allows for larger time steps when updating neutron distributions. Because of the beneficial attributes of Monte Carlo (MC) methods (exact geometries and continuous energy treatment), it is desirable to develop a MC implementation for the QS method. In this work, the latest version of the QS method known as the Predictor-Corrector Quasi-Static method is implemented. Experiments utilizing two energy-groups provide results that show good agreement with analytical and reference solutions. The method as presented can easily be implemented in any continuous energy, arbitrary geometry, MC code. (authors)

97 MATHEMATICS AND COMPUTING↗

Simulation and Optimizing Groundwater Investigations, Conceptual Design Analysis, Model Calibration and Remedial Design Using Parallel Numerical Methods: Theory and Application - 16578

Optimization of environmental restoration efforts at complex groundwater sites involves the development of a conceptual and often numerical flow and transport models. Typically, a limited number of simulations are done to assess the impact of parameter uncertainty, to evaluate remedial alternatives and develop a remedy, or to modify an existing remedy. A limited number of simulations are performed because each simulation can take upwards of several hours per simulation and until now the ability to conduct the 100's to 1000's of simulations needed to derive an optimal remedy was beyond the reach of the everyday practitioner. HGL has developed and implemented new parallel simulation and optimization methods in their software and has successfully deployed applications on high performance Cloud-based computing platforms. This advancement removes the impediment of burdensome and unpredictable runtime requirements these types of projects have typically exhibited using heuristic trial-and-error or even automated serial computation approaches. A parallel numerical solver has been added to the subsurface flow and transport simulator MODFLOW-SURFACT{sup TM} and has demonstrated reductions in solution time by as much as a factor of 9.8. This is accomplished by distributing the numerical computations of every time step over multiple processors. The integrated parallel simulation and optimization method uses the breadth and depth search approach; iteratively producing sets of tens or 100's of candidate solutions that are evaluated concurrently instead sequentially (i.e. one model evaluation at a time). Solutions within 80-100% of the globally optimal solution are regularly found expending only 5-10% of the usual computational effort using this new parallel optimization method (reducing computation effort by 10 to 20 times). Distributing optimal search runs across multiple processors additionally reduces calendar time to solutions. Practitioners evaluating multiple conceptual site models, model calibration by auto-calibration methods and remedial design by heuristics can enjoy significant reductions in model solution time by using the parallel numerical matrix solver in the physics-based simulator. Combining investigation and design analysis with breadth and depth parallel optimization methods, projects at the fringe of practical optimization, along with projects that were beyond the reach of formal optimization methods are now wholly feasible and tractable optimization problems. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Verification suite for the application of the limiting surface density method to arrays of 9975 packages

Criticality Safety Engineering at the Savannah River Site's K-Area Complex seeks to reduce the computational burden of analysis for the K-Area Complex. By applying an adapted Limiting Surface Density hand calculation method, the need for lengthy detailed Monte Carlo models of the storage arrays may be reduced or eliminated. After promising initial results using models of idealized but heterogeneous packages, application of the method to large arrays of highly heterogeneous 9975 shipping packages is attempted. A SCALE KENO-VI model of the 9975 package, with true dimensions and radial and axial heterogeneity is developed. A suite of array arrangements representing both arrays with equal number of packages per side (package-cubic) and arrays with unequal number of packages per side (non-cubic) are evaluated in SCALE. The cubic arrangements are used to derive the 9975-specific material and geometry constants for the LSD method. These constants are then used to implement the LSD method and compare the LSD- predicted critical mass per package to SCALE-predicted critical mass per package. Sensitivities to certain material and geometric nuances are evaluated for inclusion in the verification suite. Finally, the ability of the method to predict neutron multiplication changes induced by fissile mass changes is examined as a segue for evaluating credible abnormal conditions with the LSD method. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Generalized Sensitivity Calculation in the Monte Carlo Wielandt Method

Recently the Monte Carlo (MC) adjoint-weighted perturbation (AWP) methods with k-adjoint have been developed for the k sensitivity calculations. In order to extend the MC AWP methods to estimate sensitivities of a ratio of two reaction rates, Perfetti and Rearden devised a MC sensitivity calculation method with the generalized adjoint expressed by the intra-generational and intergenerational effects. Aufiero et al. suggested the collision history-based approach to calculate sensitivities of responses in the form of ratios of linear or bilinear functions by applying the correlated sampling for multi-generational collisions. However these methods may require a huge size of computer memory to save inter-generational contributions proportional to the number of the sensitivity tallies. In order to reduce memories required for the k-adjoint estimation, the present authors proposed the AWP algorithm in the MC Wielandt method where multiple generations from a fission source neutron are simulated in single history calculations. In this paper, we present perturbation formulations to estimate sensitivities for general tallies such as volume flux, reaction rates, etc. in the MC Wielandt calculations. The proposed method has been implemented into the Seoul National University MC code, McCARD and tested in two-group infinite homogeneous problems. (authors)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗