Search NASA⌕ Search

SEARCH · Search NASA

Results for “quality monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Identifying environmentally induced calibration changes in cryogenic RF axion detector systems using deep neural networks

The axion is a compelling hypothetical particle that could account for the dark matter in our universe while simultaneously solving the strong CP problem in quantum chromodynamics. The most sensitive axion detection technique demonstrated so far makes use of a high Q cavity immersed in a strong magnetic field, where axions are converted to microwave photons. This is called an axion haloscope and has primarily targeted the 1–10 GHz range. As searches scan up in axion mass, toward the parameter space favored by theoretical predictions, individual cavity sizes decrease in order to achieve higher frequencies. This shrinking cavity volume translates directly to a loss in signal-to-noise, motivating the plan to replace individual cavity detectors with arrays of cavities. When the transition from one to (N) multiple cavities occurs, haloscope searches are anticipated to become much more complicated to operate, requiring N times as many measurements but also the new requirement that N detectors operate in unison, which can be achieved by locking them to a common frequency. To offset this anticipated increase in detector complexity, we aim to develop new tools for diagnosing experiments using neural networks. Current experiments monitor scattering parameters of their receiver for periodically measuring cavity quality factor and coupling. However, off-resonant data remain relatively useless. In this paper, we ask if it is possible that off-resonant information contained in vector network analyzer scans could be used to diagnose equipment failures/anomalies and measure physical conditions (e.g., temperatures and ambient magnetic field). We demonstrate a proof-of-concept that AI techniques can help manage the complexity of an axion haloscope search for operators.

Engel, Andrew W. [Pacific Northwest National Labor↗

Computational Optimization of 133m Xe Production via Neutron Irradiation in a TRIGA Reactor

Here, the Comprehensive Nuclear-Test-Ban Treaty bans all nuclear tests worldwide. As part of treaty compliance, the concentration of radioactive nuclides in the atmosphere is monitored to detect nuclear weapons tests. Radioactive noble gas fission products, specifically radioxenon, can vent into the atmosphere after a nuclear weapons test, even if the test is well contained underground or underwater. Radioxenon thus serves as a signal for nuclear weapons tests. All atmospheric monitoring systems require samples of radioxenon isotopes for detector calibration, quality control, and certification. Here, we present a novel, improved method for creating samples of 133m Xe via neutron irradiation of 132 Xe in the Washington State University TRIGA reactor. 132 Xe neutron absorption results in either 133 Xe or 133m Xe—thermal neutron absorption results in 133m Xe 12% of the time, while fast neutron absorption (above ~1 MeV) results in 133m Xe ~50% of the time. To optimize the production of 133m Xe via neutron absorption in 132 Xe in the thermal TRIGA reactor, spectral tuning using an irradiation chamber is required to maximize the fraction of fast neutrons being absorbed and minimize the number of thermal neutrons interacting with the 132 Xe. We used MCNP to tally 132 Xe absorptions with the isotopic tally function, flux tallies and neutron attenuation to estimate the number of neutrons reaching the 132 Xe through the irradiation chamber, and the adjoint importance function to improve the source strength estimate. Additionally, we performed a heat transfer analysis for safety considerations. It was determined that the use of a 96% enriched 10 B boron carbide chamber, placed next to the fuel elements in reactor position D8, increases the 133m Xe/ 133 Xe activity ratio from a baseline value of 0.3 to 1.0, a 233% increase. Additionally, it was determined that the alpha heating produced in the boron does not become an unmanageable problem in the Washington State University reactor.

37 - INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL C↗

Moving from gamma passing rates to patient DVH-based QA metrics in pretreatment dose QA

Purpose: The purpose of this work is to explore the usefulness of the gamma passing rate metric for per-patient, pretreatment dose QA and to validate a novel patient-dose/DVH-based method and its accuracy and correlation. Specifically, correlations between: (1) gamma passing rates for three 3D dosimeter detector geometries vs clinically relevant patient DVH-based metrics; (2) Gamma passing rates of whole patient dose grids vs DVH-based metrics, (3) gamma passing rates filtered by region of interest (ROI) vs DVH-based metrics, and (4) the capability of a novel software algorithm that estimates corrected patient Dose-DVH based on conventional phan-tom QA data are analyzed. Methods: Ninety six unique ''imperfect'' step-and-shoot IMRT plans were generated by applying four different types of errors on 24 clinical Head/Neck patients. The 3D patient doses as well as the dose to a cylindrical QA phantom were then recalculated using an error-free beam model to serve as a simulated measurement for comparison. Resulting deviations to the planned vs simulated measured DVH-based metrics were generated, as were gamma passing rates for a variety of difference/distance criteria covering: dose-in-phantom comparisons and dose-in-patient comparisons, with the in-patient results calculated both over the whole grid and per-ROI volume. Finally, patient dose and DVH were predicted using the conventional per-beam planar data as input into a commercial ''planned dose perturbation'' (PDP) algorithm, and the results of these predicted DVH-based metrics were compared to the known values. Results: A range of weak to moderate correlations were found between clinically relevant patient DVH metrics (CTV-D95, parotid D{sub mean}, spinal cord D1cc, and larynx D{sub mean}) and both 3D detector and 3D patient gamma passing rate (3%/3 mm, 2%/2 mm) for dose-in-phantom along with dose-in-patient for both whole patient volume and filtered per-ROI. There was considerable scatter in the gamma passing rate vs DVH-based metric curves. However, for the same input data, the PDP estimates were in agreement with actual patient DVH results. Conclusions: Gamma passing rate, even if calculated based on patient dose grids, has generally weak correlation to critical patient DVH errors. However, the PDP algorithm was shown to accurately predict the DVH impact using conventional planar QA results. Using patient-DVH-based metrics IMRT QA allows per-patient dose QA to be based on metrics that are both sensitive and specific. Further studies are now required to analyze new processes and action levels associated with DVH-based metrics to ensure effectiveness and practicality in the clinical setting.

61 RADIATION PROTECTION AND DOSIMETRY↗

TH-C-12A-11: Target Correlation of a 3D Surface Surrogate for Left Breast Irradiation Using the Respiratory-Gated Deep-Inspiration Breath-Hold Technique

Purpose: To evaluate the use of 3D optical surface imaging as a new surrogate for respiratory motion gated deep-inspiration breath-hold (DIBH) technique for left breast cancer patients. Methods: Patients with left-sided breast cancer after lumpectomy or mastectomy were selected as candidates for DIBH technique for their external beam radiation therapy. Treatment plans were created on both free breathing (FB) and DIBH CTs to determine whether DIBH was beneficial in reducing heart doses. The Real-time Position Management (RPM) system was used to acquire patient's breathing trace during DIBH CT acquisition and treatment delivery. The reference 3D surface models from FB and DIBH CTs were generated and transferred to the “AlignRT” system for patient positioning and real-time treatment monitoring. MV Cine images were acquired for each beam as quality assurance for intra-fractional position verification. The chest wall excursions measured on these images were used to define the actual target position during treatment, and to investigate the accuracy and reproducibility of RPM and AlignRT. Results: Reduction in heart dose can be achieved for left-sided breast patients using DIBH. Results showed that RPM has poor correlation with target position, as determined by the MV Cine imaging. This indicates that RPM may not be an adequate surrogate in defining the breath-hold level when used alone. Alternatively, the AlignRT surface imaging demonstrated a better correlation with the actual CW excursion during DIBH. Both the vertical and magnitude real-time deltas (RTDs) reported by AlignRT can be used as the gating parameter, with a recommend threshold of ±3 mm and 5 mm, respectively. Conclusion: 3D optical surface imaging serves as a superior target surrogate for the left breast treatment when compared to RPM. Working together with the realtime MV Cine imaging, they ensure accurate patient setup and dose delivery, while minimizing the imaging dose to patients.

60 APPLIED LIFE SCIENCES↗

Fast leaf-fitting with generalized underdose/overdose constraints for real-time MLC tracking

Purpose: Real-time multileaf collimator (MLC) tracking is a promising approach to the management of intrafractional tumor motion during thoracic and abdominal radiotherapy. MLC tracking is typically performed in two steps: transforming a planned MLC aperture in response to patient motion and refitting the leaves to the newly generated aperture. One of the challenges of this approach is the inability to faithfully reproduce the desired motion-adapted aperture. This work presents an optimization-based framework with which to solve this leaf-fitting problem in real-time. Methods: This optimization framework is designed to facilitate the determination of leaf positions in real-time while accounting for the trade-off between coverage of the PTV and avoidance of organs at risk (OARs). Derived within this framework, an algorithm is presented that can account for general linear transformations of the planned MLC aperture, particularly 3D translations and in-plane rotations. This algorithm, together with algorithms presented in Sawant et al. [“Management of three-dimensional intrafraction motion through real-time DMLC tracking,” Med. Phys. 35, 2050–2061 (2008)] and Ruan and Keall [Presented at the 2011 IEEE Power Engineering and Automation Conference (PEAM) (2011) (unpublished)], was applied to apertures derived from eight lung intensity modulated radiotherapy plans subjected to six-degree-of-freedom motion traces acquired from lung cancer patients using the kilovoltage intrafraction monitoring system developed at the University of Sydney. A quality-of-fit metric was defined, and each algorithm was evaluated in terms of quality-of-fit and computation time. Results: This algorithm is shown to perform leaf-fittings of apertures, each with 80 leaf pairs, in 0.226 ms on average as compared to 0.082 and 64.2 ms for the algorithms of Sawant et al., Ruan, and Keall, respectively. The algorithm shows approximately 12% improvement in quality-of-fit over the Sawant et al. approach, while performing comparably to Ruan and Keall. Conclusions: This work improves upon the quality of the Sawant et al. approach, but does so without sacrificing run-time performance. In addition, using this framework allows for complex leaf-fitting strategies that can be used to account for PTV/OAR trade-off during real-time MLC tracking.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-T-669: Commissioning of An Electronic Brachytherapy System for Targeted Mouse Irradiation

Purpose: The aim of this study was to commission the Xoft Axxent™ electronic brachytherapy (eBT) source and 10 mm diameter surface applicator with NIST traceability for targeted irradiations of mouse anal carcinomas. Methods: The Xoft Axxent™ electronic brachytherapy (eBT) and 10 mm diameter surface applicator was chosen by the collaborating physician as a radiation delivery mechanism for mouse anal carcinomas. The target dose was 2 Gy at a depth of 3 mm in tissue to be delivered in a single fraction. To implement an accurate and reliable irradiation plan, the system was commissioned by first determining the eBT source output and corresponding dose rate at a depth of 3 mm in tissue. This was determined through parallel-plate ion chamber measurements and published conversion factors. Well-type ionization chamber measurements were used to determine a transfer coefficient, which correlates the measured dose rate at 3 mm to the NIST-traceable quantity, air-kerma rate at 50 cm in air, for eBT sources. By correlating these two quantities, daily monitoring in the well chamber becomes an accurate and efficient quality assurance technique. Once the dose-rate was determined, a treatment recipe was developed and confirmed with chamber measurements to deliver the requested dose. Radiochromic film was used to verify the dose distribution across the field. Results: Dose rates at 3 mm depth in tissue were determined for two different Xoft Axxent™ sources and correlated with NIST-traceable well-type ionization chamber measurements. Unique transfer coefficients were determined for each source and the treatment recipe was validated by measurements. Film profiles showed a uniform dose distribution across the field. Conclusion: A Xoft Axxent™ eBT system was successfully commissioned for use in the irradiation of mouse rectal tumors. Dose rates in tissue were determined as well as other pertinent parameters to ensure accurate delivery of dose to the target region.

60 APPLIED LIFE SCIENCES↗

Seaborne Delivery Interdiction of Weapons of Mass Destruction (WMD)

Over the next 10-20 years, the probability of a terrorist attack using a weapon of mass destruction (WMD) on the United States is projected to increase. At some point over the next few decades, it may be inevitable that a terrorist group will have access to a WMD. The economic and social impact of an attack using a WMD anywhere in the world would be catastrophic. For weapons developed overseas, the routes of entry are air and sea with the maritime vector as the most porous. Providing a system to track, perform a risk assessment and inspect all inbound marine traffic before it reaches US coastal cities thereby mitigating the threat has long been a goal for our government. The challenge is to do so effectively without crippling the US economy. The Portunus Project addresses only the maritime threat and builds on a robust maritime domain awareness capability. It is a process to develop the technologies, policies and practices that will enable the US to establish a waypoint for the inspection of international marine traffic, screen 100% of containerized and bulk cargo prior to entry into the US if deemed necessary, provide a palatable economic model for transshipping, grow the US economy, and improve US environmental quality. The implementation strategy is based on security risk, and the political and economic constraints of implementation. This article is meant to provide a basic understanding of how and why this may be accomplished.

99 GENERAL AND MISCELLANEOUS↗

2013 Annual Industrial Wastewater Reuse Report for the Idaho National Laboratory Site’s Materials and Fuels Complex Industrial Waste Ditch and Industrial Waste Pond

This report describes conditions, as required by the state of Idaho Industrial Wastewater Reuse Permit (WRU-I-0160-01, formerly LA 000160 01), for the wastewater reuse site at the Idaho National Laboratory Site’s Materials and Fuels Complex Industrial Waste Ditch and Industrial Waste Pond from November 1, 2012 through October 31, 2013. The report contains the following information: (1) Facility and system description; (2) Permit required effluent monitoring data and loading rates; (3) Groundwater monitoring data; (4) Status of special compliance conditions; and (5) Discussion of the facility’s environmental impacts During the 2013 reporting year, an estimated 9.64 million gallons of wastewater were discharged to the Industrial Waste Ditch and Pond which is well below the permit limit of 17 million gallons per year. The concentrations of all permit-required analytes in the samples from the down gradient monitoring wells were below the applicable Idaho Department of Environmental Quality’s groundwater quality standard levels.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

2014 Annual Industrial Wastewater Reuse Report for the Idaho National Laboratory Site’s Materials and Fuels Complex Industrial Waste Ditch and Industrial Waste Pond

This report describes conditions, as required by the state of Idaho Industrial Wastewater Reuse Permit (WRU-I-0160-01, formerly LA 000160 01), for the wastewater reuse site at the Idaho National Laboratory Site’s Materials and Fuels Complex Industrial Waste Ditch and Industrial Waste Pond from November 1, 2013 through October 31, 2014. The report contains the following information; Facility and system description; Permit required effluent monitoring data and loading rates; Groundwater monitoring data; Status of special compliance conditions; Noncompliance issues; and Discussion of the facility’s environmental impacts During the 2014 reporting year, an estimated 10.11 million gallons of wastewater were discharged to the Industrial Waste Ditch and Pond which is well below the permit limit of 17 million gallons per year. The concentrations of all permit-required analytes in the samples from the down gradient monitoring wells were below the applicable Idaho Department of Environmental Quality’s groundwater quality standard levels.

2014 Annual Industrial Wastewater Reuse Report for↗

Identifying Suspect Instrument Intervals Using Midnight Noise Time Histories

With an intense work ethic, and high levels of devotion to their craft, seismologists continue to battle the elements and wrestle with complex logistics in their efforts to field instrumentation over the entire globe. We are fortunate to see data volumes accelerating in size, and quality continuing to improve; for example, universal timing issues can now be considered rare. However, instrument response issues are still common, and can hinder research that seeks to understand amplitudes of seismic wavefields. We are interested in using the accumulations of seismic data to develop models that will predict high frequency (0.2-20 Hz, and higher) signal amplitudes for explosion monitoring purposes over broad areas, which requires large data sets and extensive quality control. To identify response and station health issues, we have collected noise time histories for global seismic data, focusing on measurements near (but not restricted to) midnight to eliminate diurnal variations, and have manually determined time intervals that appear inconsistent with background behavior. We assign descriptive labels, but do not attempt to diagnose causes. We use these intervals to discard data. To date, we have examined 39,260 channels from 11,105 stations, heavily weighted toward IRIS holdings, dates through 2017 (depending on station, roughly the date we started our manual review), bands between 1 and 8 Hz, finding 24,733 anomalous time intervals. The great majority (90%) of these intervals appear to be shifts of constant offset, often bounded by times of known instrument changes, likely the result of poor documentation of response parameters at one of many stages between the field and the plotter. We hope these results can be of use to our colleagues, and would encourage community efforts to diagnose anomalous behavior, and fix poor responses. We also hope these results will support automation efforts, including application of supervised learning techniques.

47 OTHER INSTRUMENTATION↗

GMS Station SOH Monitoring Users Guide (V.1.2)

The Geophysical Monitoring System (GMS) State-of-Health User Interface (SOH UI) is a web-based application that allows a user to view and acknowledge the SOH status of stations in the GMS system. The SOH UI will primarily be used by the System Controller, who monitors and controls the system and external data connections. The System Controller uses the station SOH UIs to monitor, detect, and troubleshoot problems with station data availability and quality.

58 GEOSCIENCES↗

Structural Health Monitoring: Using an Autoencoder to Identify Damage in a Bolted Joint [Capstone Project]

Los Alamos National Laboratory (LANL) is an important fixture in the United States Department of Energy’s (DOE) National Nuclear Security Agency (NNSA) complex. LANL is one of the largest national laboratories in the country, and the laboratory’s primary mission is to support the nation’s nuclear stockpile. The lab functions as a design agencies for the NNSA and performs extensive testing on weapons as part of that mission. The shock and vibration test team at LANL utilizes electrodynamic shaker systems for important qualification testing in support of the laboratory’s mission. Modern engineering relies heavily on bolted joints to connect two objects. During these shaker tests, engineers depend on bolted joints to secure the test article to a fixture and the fixture to the table. The test article may be hazardous and contain high explosives which could create a safety issue if a bolted joint failed. A loss of preload in a bolt will affect the way energy is input to the system and may introduce nonlinearities as the joint opens and closes. The loss of preload can create challenges controlling the test and make acquired signals useless. Being able to monitor preload within bolted joints during testing can improve the quality of the data and keep workers safe.

42 ENGINEERING↗

Electrochemical Acid Sequestration to Ease Ocean Acidification (EASE-OA) - CRADA 600 (Abstract)

The PNNL team will coordinate logistics involved with setting up the field trial on the PNNL Sequim campus in collaboration with Ebb Carbon. Facilities on the PNNL Sequim campus are capable of pumping raw or filtered seawater from Sequim Bay at a rate ~45,000 L hr -1 , which can accommodate the 4000 L hr -1 requirement of the 200 ton CO2 yr-1 Ebb Carbon marine carbon dioxide removal (mCDR) system. The primary tasks for the PNNL team are 1) laying out appropriate indoor and outdoor spaces for installing the Ebb Carbon’s mCDR system, 2) facilitating Ebb Carbon’s access to the PNNL’s seawater intake on the PNNL Sequim campus, 3) conducting mesocosm experiments within the PNNL Sequim campus laboratories to test how the brine and base discharged from the Ebb Carbon system affect marine life, and 4) facilitating Ebb Carbon access to the PNNL Sequim installation site and aiding in maintenance as needed. In addition to these tasks, the PNNL team will provide surface water quality data (e.g., salinity, temperature, pH, dissolved O2) from a monitoring station located on the pier to contextualize starting conditions of the seawater used in the mCDR process. Finally, the PNNL team will also consult with Ebb Carbon on strategies for improving overall system performance and next steps for further scaling and/or monitoring the effectiveness of the mCDR system.

54 ENVIRONMENTAL SCIENCES↗

Summary of the Hanford Site Environmental Report for Calendar Year 2007

This summary booklet summarizes the "Hanford Site Environmental Report for Calendar Year 2007." The Hanford Site environmental report, published annually since 1958, includes information and summary data that provide an overview of activities at the U.S. Department of Energy's (DOE) Hanford Site. The Hanford Site environmental report provides an overview of activities at the site; demonstrates the status of the site’s compliance with applicable federal, state, and local environmental laws and regulations, executive orders, and DOE policies and directives; and summarizes environmental data that characterize Hanford Site environmental management performance. The report also highlights signifi cant environmental and public protection programs and efforts. Some historical and early 2008 information is included where appropriate.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Summary of the Hanford Site Environmental Report for Calendar Year 2008

This summary booklet summarizes the "Hanford Site Environmental Report for Calendar Year 2008." The Hanford Site environmental report, published annually since 1958, includes information and summary data that provide an overview of activities at the U.S. Department of Energy's (DOE) Hanford Site. The Hanford Site environmental report provides an overview of activities at the site; demonstrates the status of the site’s compliance with applicable federal, state, and local environmental laws and regulations, executive orders, and DOE policies and directives; and summarizes environmental data that characterize Hanford Site environmental management performance. The report also highlights significant environmental and public protection programs and efforts. Some historical and early 2009 information is included where appropriate.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Payload operation television system

The TV system assembled is intended for laboratory experimentation which would develop operational techniques and lead to the design of space-borne TV equipment whose purpose would be to assist the astronaut-operator aboard a space station to load payload components. The TV system assembled for this program is a black and white, monocular, high performance system. The equipment consists principally of a good quality TV camera capable of high resolving power; a TV monitor; a sync generator for driving camera and monitor; and two pan/tilt units which are remotely controlled by the operator. One pan/tilt unit provides control of the pointing of the camera, the other similarly controls the position of a simulated payload.

Source record↗

Environmental monitoring of the orbiter payload bay and Orbiter Processing Facilities

Contamination control in the Orbiter Processing Facility (OPF) is studied. The clean level required in the OPF is generally clean, which means no residue, dirt, debris, or other extraneous contamination; various methods of maintaining this level of cleanliness are described. The monitoring and controlling of the temperature, relative humidity, and air quality in the OPF are examined. Additional modifications to the OPF to improve contamination control are discussed. The methods used to maintain the payload changeout room at a level of visually clean, no particulates are to be detected by the unaided eye, are described. The payload bay (PLB) must sustain the cleanliness level required for the specific Orbiter's mission; the three levels of clean are defined as: (1) standard, (2) sensitive, and (3) high sensitive. The cleaning and inspection verification required to achieve the desired cleanliness level on a variety of PLB surface types are examined.

Bartelson, D. W.↗

An improved plating process

An alternative to the immersion process for the electrodeposition of chromium from aqueous solutions on the inside diameter (ID) of long tubes is described. The Vessel Plating Process eliminates the need for deep processing tanks, large volumes of solutions, and associated safety and environmental concerns. Vessel Plating allows the process to be monitored and controlled by computer thus increasing reliability, flexibility and quality. Elimination of the trivalent chromium accumulation normally associated with ID plating is intrinsic to the Vessel Plating Process. The construction and operation of a prototype Vessel Plating Facility with emphasis on materials of construction, engineered and operational safety and a unique system for rinse water recovery are described.

Askew, John C.↗