Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTROMAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Radiation and Electromagnetic Induction Data Fusion for Detection of Buried Radioactive Metal Waste - 12282

At the United States Army's test sites, fired penetrators made of Depleted Uranium (DU) have been buried under ground and become hazardous waste. Previously, we developed techniques for detecting buried radioactive targets. We also developed approaches for locating buried paramagnetic metal objects by utilizing the electromagnetic induction (EMI) sensor data. In this paper, we apply data fusion techniques to combine results from both the radiation detection and the EMI detection, so that we can further distinguish among DU penetrators, DU oxide, and non- DU metal debris. We develop a two-step fusion approach for the task, and test it with survey data collected on simulation targets. In this work, we explored radiation and EMI data fusion for detecting DU, oxides, and non-DU metals. We developed a two-step fusion approach based on majority voting and a set of decision rules. With this approach, we fuse results from radiation detection based on the RX algorithm and EMI detection based on a 3-step analysis. Our fusion approach has been tested successfully with data collected on simulation targets. In the future, we will need to further verify the effectiveness of this fusion approach with field data. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

THE RESOLVED NEAR-INFRARED EXTRAGALACTIC BACKGROUND

We present a current best estimate of the integrated near-infrared (NIR) extragalactic background light (EBL) attributable to resolved galaxies (Integrated Galaxy Light, IGL) in J, H, and K{sub s} . Our results for measurements of {nu}I{nu} in units of nW m{sup -2} sr{sup -1} are 11.7{sup +5.6}{sub -2.6} in J, 11.5{sup +4.5}{sub -1.5} in H, and 10.0{sup +2.8}{sub -0.8} in K{sub s} . We derive these new limits by combining our deep wide-field NIR photometry from five widely separated fields with other studies from the literature to create a galaxy counts sample that is highly complete and has good counting statistics out to JHK{sub s} {approx} 27-28. As part of this effort we present new ultra-deep K{sub s} -band galaxy counts from 22 hr of observations with the Multi Object Infrared Camera and Spectrograph (MOIRCS) instrument on the Subaru Telescope. We use this MOIRCS K{sub s} -band mosaic to estimate the total missing flux from sources beyond our detection limits. Our new limits to the NIR EBL are in basic agreement with, but 10%-20% higher than, previous estimates, bringing them into better agreement with estimates of the total NIR EBL (resolved + unresolved sources) obtained from TeV {gamma}-ray opacity measurements and recent direct measurements of the total NIR EBL as well as the modeled NIR IGL. We examine field-to-field variations in our photometry to show that the integrated light from galaxies is isotropic to within uncertainties, consistent with the expected large-scale isotropy of the EBL. Our data also allow for a robust estimate of the NIR light from Galactic stars, which we find to be 14.7 {+-} 2.4 in J, 10.1 {+-} 1.9 in H, and 7.6 {+-} 1.8 in K{sub s} in units of nW m{sup -2} sr{sup -1}.

79 ASTRONOMY AND ASTROPHYSICS↗

A Polar Scaling Technique for the Regularization of Strongly Singular and Strongly Near-Singular Helmholtz Surface Integrals Evaluated Over 2-D Domains

The numerical integration of expressions containing strong singularities or strong near-singularities has long been a challenging problem in the electromagnetics community. Much attention has been paid to this problem, as strong $1/R^{{2}}$ singularities routinely appear when implementing electromagnetic simulation techniques like the method of moments (MoM). To date, several techniques, from singularity extraction to singularity cancellation (SC), have been employed to deal with problems that require the evaluation of 2-D strongly singular integrals. However, no single technique has been proposed that can deal with both strong singularities and strong near-singularities in a fully numerical manner for arbitrary 2-D domains. Moreover, it has been claimed that the Helmholtz-type strongly singular integral found in the MoM is convergent in a principal value sense, but this convergence value has yet to be proven mathematically. In this work, we will conduct the convergence proof and introduce a “polar scaling” change of variables method that may be used to evaluate Helmholtz integrals with both strong and weak singularities/near-singularities. The technique is fully numerical and can in principle be applied to any planar or curved polygon and any nonsingular basis function. We will also provide numerical results showing useful convergence behavior for integrals involving both exact and near-singularities.

47 OTHER INSTRUMENTATION↗

Implementation of wireless technologies in nuclear power plants' electromagnetic environment using cognitive radio system - 153

Wireless technologies have increased efficiency in many industrial settings across the world by enabling a mobile workforce and improving communications. Unfortunately, the nuclear power industry has been slow to adopt wireless technology as a result of safety, security, and reliability concerns expressed by regulators and others. A Research and Development (R and D) effort is currently being conducted to address two significant technical concerns for the introduction of wireless technology in nuclear power plants, which are electromagnetic compatibility (EMC) and wireless coexistence. Most equipment in nuclear power plants has never been tested for vulnerability to wireless transmission. As such, the impact of modern wireless devices on nuclear safety and plant reliability is not understood. Existing guidance from the Nuclear Regulatory Commission (NRC) and Electric Power Research Institute (EPRI) rely on the use of exclusion zones to protect plant equipment, which can result in exclusion zones of up to eight feet for some tablet devices rendering them ineffective for the mobile workforce. Another unknown is how different wireless devices will operate in close proximity to one another in the harsh electromagnetic environment of a nuclear power plant. These issues are being addressed through development of a cognitive radio system that has the ability to generate and output multiple wireless signals such as Wi-Fi, Bluetooth, and cellular communications at varying power levels and frequencies. The cognitive radio system is a modular system that can test nuclear plant equipment located in training areas, simulators, and the actual plant environment. In addition to using the system for testing plant equipment to wireless signals and EMC standards, the system can also monitor the radio spectrum for usage in other plant focuses such as cyber security. The R and D work will provide the objective guidance for the nuclear industry in the two areas mentioned and will develop a cognitive radio system for in-plant EMC and coexistence testing. The system will assist in the seamless use of wireless technology in nuclear power plants while greatly reducing the risks wireless signals may introduce. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Integration of RFQ beam coolers and solenoidal magnetic fields

Electromagnetic traps are a flexible and powerful method of controlling particle beams, possibly of exotic nuclei, with cooling (of energy spread and transverse oscillations) provided by collisions with light gases as in the Radio Frequency Quadrupole Cooler (RFQC). A RFQC prototype can be placed inside the existing Eltrap solenoid, capable of providing a magnetic flux density component B{sub z} up to 0.2 T, where z is the solenoid axis. Confinement in the transverse plane is provided both by B{sub z} and the rf voltage V{sub rf} (up to 1 kV at few MHz). Transport is provided by a static electric field E{sub z} (order of 100 V/m), while gas collisions (say He at 1 Pa, to be maintained by differential pumping) provide cooling or heating depending on V{sub rf}. The beamline design and the major parameters V{sub rf}, B{sub z} (which affect the beam transmission optimization) are here reported, with a brief description of the experimental setup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status of Dual-readout R&D for a Linear Collider in T1015 Collaboration

The hadronic energy resolution required for an hadronic operating at lepton collider is at the limits or even exceeds that obtained with traditional techniques. Furthermore, it is a well established fact that the presence of an electromagnetic section in front of an hadron calorimeter, as occurs in the layouts of the majority of detectors operating at a collider, would deteriorate the hadronic energy resolution of the device. The novel $ADRIANO$ technology (\textit{A Dual-readout Integrally Active Non-segmented Option}), currently under development at Fermilab, overcomes the above limitations by complementing an integrally active calorimeter with the dual-readout technique. Detailed Monte Carlo studies indicate that the energy resolution is in the $25\%/\sqrt{E}$ - $38\%/\sqrt{E}$ interval with a linear response of the detector up to an energy of 200 GeV. A baseline configuration is chosen with an estimated energy resolution of $\sigma(E)/E\approx30\%/\sqrt{E}$. Several prototypes have been built by \textit{T1015} Collaboration at Fermilab, to explore the effect of modifications of the layout from the baseline configuration. Preliminary results from several test beams at the \textit{Fermilab Test Beam Facility} (FTBF) of $\sim1\lambda_{I}$ prototypes are presented. Future prospects with ultra-heavy glass are, also, summarized.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Opto-electrochemical spectroscopy of metals in aqueous solutions

In the present investigation, holographic interferometry was utilized for the first time to determine the rate change of the electrical resistance of aluminium samples during the initial stage of anodisation processes in aqueous solution. In fact, because the resistance values in this investigation were obtained by holographic interferometry, electromagnetic method rather than electronic method, the abrupt rate change of the resistance was called electrical resistance–emission spectroscopy. The anodisation process of the aluminium samples was carried out by electrochemical impedance spectroscopy (EIS) in different sulphuric acid concentrations (1.0%–2.5% H{sub 2}SO{sub 4}) at room temperature. In the meantime, the real time holographic interferometry was used to determine the difference between the electrical resistance of two subsequent values, dR, as a function of the elapsed time of the EIS experiment for the aluminium samples in 1.0%, 1.5%, 2.0%, and 2.5% H{sub 2}SO{sub 4} solutions. The electrical resistance–emission spectra of the present investigation represent a detailed picture of not only the rate change of the electrical resistance throughout the anodisation processes but also the spectra represent the rate change of the growth of the oxide films on the aluminium samples in different solutions. As a result, a new spectrometer was developed based on the combination of the holographic interferometry and electrochemical impedance spectroscopy for studying in situ the electrochemical behavior of metals in aqueous solutions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Maximizing quantum enhancement in axion dark matter experiments

We provide a comprehensive comparison of linear amplifiers and microwave photon counters in axion dark matter experiments. The study is done assuming a range of realistic operating conditions and detector parameters, over the frequency range between 1 and 30 GHz. As expected, photon counters are found to be advantageous under low background, at high frequencies (𝜈 >5 GHz), if they can be implemented with robust wide-frequency tuning or a very low dark count rate. Additional noteworthy observations emerging from this study include: (1) an expanded applicability of off-resonance photon background reduction, including the single-quadrature state squeezing, for scan rate enhancements; (2) a much broader appeal for operating the haloscope resonators in the overcoupling regime, up to 𝛽 ∼10; (3) the need for a detailed investigation into the cryogenic and electromagnetic conditions inside haloscope cavities to lower the photon temperature for future experiments; (4) the necessity to develop a distributed network of coupling ports in high-volume axion haloscopes to utilize these potential gains in the scan rate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-J-38: Comparison of 6MV Photon Dose in a Perpendicular and Parallel Magnetic Field

Purpose: Integrating a linac with an MRI system would allow for real time tumour tracking however the patient will be irradiated in the presence of a magnetic field. The present study experimentally investigates the magnetic field effects on entrance, exit, and interface dose for both transverse and parallel magnetic fields. Methods: Polystyrene was used to construct a set of phantoms for Gafchromic film measurements. One phantom had an adjustable air gap and four other phantoms had one surface at various angles. The linac-MR prototype consisting of a biplanar permanent magnet coupled to a linac was used for the transverse magnetic field measurements. A couple of solenoid electromagnets, stacked on top of each other and irradiated along their bore, were used for the parallel field measurements. Results: All doses are relative to no magnetic field. The transverse magnetic field reduced the entrance dose for all surface angles by strongly deflecting the contaminant electrons. The exit dose in a transverse magnetic field was found to be significantly higher. The entrance dose with a parallel magnetic field present is higher due to the contaminant electrons being concentrated within the beam area. The air gap phantom measurements, done in a transverse magnetic field, show a significant increase of the dose at the proximal side of the air gap and a decrease at the distal side. The measurements, done in the parallel magnetic field, show the concentration of secondary electrons in the air gap. Conclusion: The radiation dose measurements of a 6MV beam in a parallel and transverse magnetic field presented here are currently being replicated using Monte Carlo simulations. This verified Monte Carlo system could provide the dose calculation basis for future linac-MR systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of charge state distributions using a scintillation screen

Absolute cross sections measured using electromagnetic devices to separate and detect heavy recoiling ions need to be corrected for charge state fractions. Accurate prediction of charge state distributions using theoretical models is not always a possibility, especially in energy and mass regions where data is sparse. As such, it is often necessary to measure charge state fractions directly. In this paper we present a novel method of using a scintillation screen along with a CMOS camera to image the charge dispersed beam after a set of magnetic dipoles. A measurement of the charge state distribution for 88 Sr passing through a natural carbon foil is performed. Using a Bayesian model to extract statistically meaningful uncertainties from these images, we find agreement between the new method and a more traditional method using Faraday cups. Additional future work is need to better understand systematic uncertainties. Our technique offers a viable method to measure charge state distributions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Construction and development of a time-resolved x-ray magnetic circular dichroism-photoelectron emission microscopy system using femtosecond laser pulses at BL25SU SPring-8

A femtosecond pulsed laser system has been installed at the BL25SU soft x-ray beamline at SPring-8 for time-resolved pump-probe experiments with synchronization of the laser pulses to the circularly polarized x-ray pulses. There are four different apparatuses situated at the beamline; for photoemission spectroscopy, two-dimensional display photoelectron diffraction, x-ray magnetic circular dichroism (XMCD) with electromagnetic coils, and photoelectron emission microscopy (PEEM). All four can be used for time-resolved experiments, and preliminary investigations have been carried out using the PEEM apparatus to observe magnetization dynamics in combination with XMCD. In this article, we describe the details of the stroboscopic pump-probe XMCD-PEEM experiment, and present preliminary data. The repetition rate of the laser pulses is set using a pulse selector to match the single bunches of SPring-8's hybrid filling pattern, which consists of several single bunches and a continuous bunch train. Electrons ejected during the bunch train, which do not provide time-resolved signal, are eliminated by periodically reducing the channel plate voltage using a custom-built power supply. The pulsed laser is used to create 300 ps long magnetic field pulses, which cause magnetic excitations in micron-sized magnetic elements which contain magnetic vortex structures. The observed frequency of the motion is consistent with previously reported observations and simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SWIFT MONITORING OF CYGNUS X-2: INVESTIGATING THE NEAR-ULTRAVIOLET-X-RAY CONNECTION

The neutron star X-ray binary (NSXRB) Cyg X-2 was observed by the Swift satellite 51 times over a 4 month period in 2008 with the X-ray Telescope (XRT), UV/optical telescope, and Burst Alert Telescope (BAT) instruments. During this campaign, we observed Cyg X-2 in all three branches of the Z track (horizontal, normal, and flaring branches). We find that the NUV emission is uncorrelated with the soft X-ray flux detected with the XRT and is anticorrelated with the BAT X-ray flux and the hard X-ray color. The observed anticorrelation is inconsistent with simple models of reprocessing as the source of the NUV emission. The anticorrelation may be a consequence of the high inclination angle of Cyg X-2, where NUV emission is preferentially scattered by a corona that expands as the disk is radiatively heated. Alternatively, if the accretion disk thickens as Cyg X-2 goes down the normal branch toward the flaring branch, this may be able to explain the observed anticorrelation. In these models, the NUV emission may not be a good proxy for m-dot in the system. We also discuss the implications of using Swift/XRT to perform spectral modeling of the continuum emission of NSXRBs.

79 ASTRONOMY AND ASTROPHYSICS↗

A new Scanning Transmission X-ray Microscope at the ALS for operation up to 2500eV

We report on the design and construction of a higher energy Scanning Transmission X-ray Microscope on a new bend magnet beam line at the Advanced Light Source. Previously we have operated such an instrument on a bend magnet for C, N and O 1s NEXAFS spectroscopy. The new instrument will have similar performance at higher energies up to and including the S 1s edge at 2472eV. A new microscope configuration is planned. A more open geometry will allow a fluorescence detector to count emitted photons from the front surface of the sample. There will be a capability for zone plate scanning in addition to the more conventional sample scanning mode. This will add the capability for imaging a massive sample at high resolution over a limited field of view, so that heavy reaction cells may be used to study processes in-situ, exploiting the longer photon attenuation length and the longer zone plate working distances available at higher photon energy. The energy range will extend down to include the C1s edge at 300eV, to allow high energy NEXAFS microscopic studies to correlate with the imaging of organics in the same sample region of interest.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

JETS IN POLAR CORONAL HOLES

Here, we explore the nature of small-scale jet-like structures and their possible relation to explosive events and other known transient features, like spicules and macrospicules, using high-resolution spectroscopy obtained with the Solar and Heliospheric Observatory/Solar Ultraviolet Measurements of Emitted Radiation instrument. We present a highly resolved spectroscopic analysis and line parameter study of time-series data for jets occurring on-disk and off-limb in both a northern and a southern coronal hole. The analysis reveals many small-scale transients which rapidly propagate between the mid-transition region (N IV 765 A line formation: 140,000 K) and the lower corona (Ne VIII 770 A line formation: 630,000 K). In one example, a strong jet-like event is associated with a cool feature not present in the Ne VIII 770 A line radiance or Doppler velocity maps. Another similar event is observed, but with a hot component, which could be perceived as a blinker. Our data reveal fast, repetitive plasma outflows with blueshift velocities of approx145 km s{sup -1} in the lower solar atmosphere. The data suggest a strong role for smaller jets (spicules), as a precursor to macrospicule formation, which may have a common origin with explosive events.

79 ASTRONOMY AND ASTROPHYSICS↗

A Method to Reduce the Coherent Betatron Oscillations in a Muon g-2 Storage Ring Experiment using RF Fields

The muon $g-2$ storage-ring experiments store a beam of polarized muons in a weak focusing storage ring. As the ensemble of muons goes around the ring, their spin precesses, and when they decay through the weak interaction: $\mu^+ \rightarrow e^+ \nu_e \bar{\nu_\mu}$ the decay positrons are detected by electromagnetic calorimeters. In addition to the expected exponential decay in the positron time spectrum, the weak decay asymmetry causes a modulation in the number of positrons at the difference frequency between the spin and cyclotron frequencies, $\omega_a$. This frequency is directly proportional to the magnetic anomaly $a =(g-2)/2$, where $g$ is the gyromagnetic ratio of the muon, which is slightly greater than 2. The detector acceptance depends on the radial position of the muon decay, so the coherent betatron oscillations (CBO) of the muon bunch following injection into the storage ring amplitude modulates the measured muon signal with the frequency $\omega_{CBO}$. A new method using radio frequency (RF) electric fields has the potential to significantly decrease the beam CBO, and additionally to scrape the beam to reduce muon losses from the storage ring during the measurement period.

43 PARTICLE ACCELERATORS↗

Ultrafast electron kinetics in short pulse laser-driven dense hydrogen

Dense cryogenic hydrogen is heated by intense femtosecond infrared laser pulses at intensities of ${10}^{15}-{10}^{16}\;$ W cm–2. Three-dimensional particle-in-cell (PIC) simulations predict that this heating is limited to the skin depth, causing an inhomogeneously heated outer shell with a cold core and two prominent temperatures of about $25$ and $40\;\mathrm{eV}$ for simulated delay times up to $+70\;\mathrm{fs}$ after the laser pulse maximum. Experimentally, the time-integrated emitted bremsstrahlung in the spectral range of 8–18 nm was corrected for the wavelength-dependent instrument efficiency. The resulting spectrum cannot be fit with a single temperature bremsstrahlung model, and the best fit is obtained using two temperatures of about 13 and $30\;$eV. The lower temperatures in the experiment can be explained by missing energy-loss channels in the simulations, as well as the inclusion of hot, non-Maxwellian electrons in the temperature calculation. In conclusion, we resolved the time-scale for laser-heating of hydrogen, and PIC results for laser–matter interaction were successfully tested against the experiment data.

42 ENGINEERING↗

Free-standing gold elliptical nanoantenna with tunable wavelength in near-infrared region for enhanced Raman spectroscopy

The purpose of this work is to present a surface-enhanced Raman scattering (SERS) amplifying antenna for the possible usage in the near-infrared region. Instead of the visible-light range amplifying antenna such as a bowtie, the finite-difference time-domain (FDTD) simulation results indicate that elliptical antenna could provide large electromagnetic field enhancement at near-infrared wavelength by combining the free-standing enhancement property with large aspect ratios of the ellipse geometry. The simulation results consist with the enhancement factors characterized by SERS measurements at the excited wavelength of 785 nm for different aspect ratios and periodicities. In addition to the redshift of the resonance wavelength as the aspect ratio of ellipse increases, the free-standing structure modifies the resonance behavior and the dielectric environment of antenna by elevating the elliptical disk from the substrate. To interpret the simulation results, the analytical solution of resonance wavelength for ellipsoid dimmer is derived based on Lorentz–Mie theory, and comparisons are made between the analytical solution and simulation results. The quasi-static analytical solution provides a way to characterize the resonance behavior of two ellipsoid particles as a function of the gap distance, aspect ratio, and dielectric environment. In conclusion, the electrodynamic analysis for the periodic structure was performed in our FDTD simulations.

47 OTHER INSTRUMENTATION↗

Femtosecond exciton dynamics in WSe 2 optical waveguides

Van-der Waals (vdW) atomically layered crystals can act as optical waveguides over a broad range of the electromagnetic spectrum ranging from Terahertz to visible. Unlike common Si-based waveguides, vdW semiconductors host strong excitonic resonances that may be controlled using non-thermal stimuli including electrostatic gating and photoexcitation. Here, we utilize waveguide modes to examine photo-induced changes of excitons in the prototypical vdW semiconductor, WSe 2 , prompted by femtosecond light pulses. Using time-resolved scanning near-field optical microscopy we visualize the electric field profiles of waveguide modes in real space and time and extract the temporal evolution of the optical constants following femtosecond photoexcitation. By monitoring the phase velocity of the waveguide modes, we detect incoherent A-exciton bleaching along with a coherent optical Stark shift in WSe 2 .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗