Search NASA⌕ Search

SEARCH · Search NASA

Results for “High Voltage Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Assessment of SOI AND Gate, Type CHT-7408, for Operation in Extreme Temperature Environments

Electronic parts based on silicon-on-insulator (SOI) technology are finding widespread applications due to their ability to operate in harsh environments and the benefits they offer as compared to their silicon counterparts. Due to their construction, they are tailored for high temperature operation and show good tolerance to radiation events. In addition, their inherent design lessens the formation of parasitic junctions, thereby reducing leakage currents, decreasing power consumption, and enhancing speed. These devices are typically rated in temperature capability from -55 C to about +225 C, and their characteristics over this temperature range are documented in data sheets. Since electronics in some of NASA space exploration missions are required to operate under extreme temperature conditions, both cold and hot, their characteristic behavior within the full temperature spectrum must be determined to establish suitability for use in space applications. The effects of extreme temperature exposure on the performance of a new commercial-off-the-shelf (COTS) SOI AND gate device were evaluated in this work. The high temperature, quad 2-inputs AND gate device, which was recently introduced by CISSOID, is fabricated using a CMOS SOI process. Some of the specifications of the CHT-7408 chip are listed in a table. By supplying a constant DC voltage to one gate input and a 10 kHz square wave into the other associated gate input, the chip was evaluated in terms of output response, output rise (t(sub r)) and fall times (tf), and propagation delays (using a 50% level between input and output during low to high (tPLH) and high to low (tPHL) transitions). The supply current of the gate circuit was also obtained. These parameters were recorded at various test temperatures between -195 C and +250 C using a Sun Systems environmental chamber programmed at a temperature rate of change of 10 C/min. In addition, the effects of thermal cycling on this chip were determined by exposing it to a total of 12 cycles between -195 C and +250 C. Following the cycling activity, measurements were performed again at the test temperatures of -195 C, +21 C, and +250 C.

Patterson, Richard↗

AD8065 Voltage Feedback Amplifier’s Total Ionizing Dose Characterization Report

The purpose of this testing was to characterize Analog Devices’ AD8065 FastFET amplifier for low-dose rate (LDR) total ionizing dose (TID) response based on the Lucy project requirements and will be used on the L’ORRI instrument being built by Johns Hopkins University Applied Physics Lab. The AD8065 is a voltage feedback amplifier with FET inputs developed with the proprietary eXtra Fast Complementary Bipolar (XFCB) process. The amplifier boasts low noise operation and very high input impedance with a wide supply voltage range.

Megan Casey↗

A Facility Effect Characterization Test of the BHT-6000 Hall Thruster

During the development of the BHT-6000 Hall thruster for flight on NASA’s Power and Propulsion Element, a facility effect test campaign was performed on an engineering unit of the thruster. Testing occurred in Vacuum Facility 5 at NASA Glenn Research Center. The goal of the test campaign was to characterize the behavior of the BHT-6000 Hall thruster as functions of facility effects such that the thruster’s in-flight behavior can be reasonably bounded. In particular, the behavior of the thruster with regard to the background pressure and electrical environment was tested. The background pressure was controlled by injecting supplemental propellant flow into the environment, while the electrical environment was controlled by biasing the facility beam dump. Thrust was found to remain constant over the tested range of pressures while specific impulse was found to increase slightly (1 to 1.5% over a range of up to 20 μTorr, depending on operating point). Plasma plume properties, particularly of ions exiting the side of the thruster, were found to be highly sensitive to pressure and may require pressures of less than a few μTorr for accurate measurements. The thruster was found to operate identically with changing beam dump bias voltage to within measurement uncertainties.

Electric propulsion↗

A Facility Effect Characterization Test of the BHT6000 Hall Thruster

During the development of the BHT-6000 Hall thruster for flight on NASA’s Power and Propulsion Element, a facility effect test campaign was performed on an engineering unit of the thruster. Testing occurred in Vacuum Facility 5 at NASA Glenn Research Center. The goal of the test campaign was to characterize the behavior of the BHT-6000 Hall thruster as functions of facility effects such that the thruster’s in-flight behavior can be reasonably bounded. In particular, the behavior of the thruster with regard to the background pressure and electrical environment was tested. The background pressure was controlled by injecting supplemental propellant flow into the environment, while the electrical environment was controlled by biasing the facility beam dump. Thrust was found to remain constant over the tested range of pressures while specific impulse was found to increase slightly (1 to 1.5% over a range of up to 20 μTorr, depending on operating point). Plasma plume properties, particularly of ions exiting the side of the thruster, were found to be highly sensitive to pressure and may require pressures of less than a few μTorr for accurate measurements. The thruster was found to operate identically with changing beam dump bias voltage to within measurement uncertainties.

Electric propulsion↗

Importance of High Valence Element Nb in Ni-Rich Layered Cathodes for High-Voltage Lithium-Metal Batteries

Ni-rich layered cathode materials have attracted extensive attention due to their higher energy density and technological maturity in commercialization. As the nickel content is raised, especially surpassing 80%, the increased energy density comes with the tradeoff of diminished thermal stability and increased electrochemical structural instability of the cathode. Compared with Co, Al, B, and Ta, the introduction of high valence element Nb significantly improved the electrochemical cycling, delivering a capacity of 202 mAh/g, corresponding to a capacity retention of 92% after 200 cycles tested at 45 °C. Further, the ex situ differential scanning calorimetry and in situ isothermal microcalorimetry demonstrate that the Nb-modified cathode has the potential to enhance the safety of ultrahigh nickel (Ni) NMCs and displays remarkable resilience to extensive cycling by inhibiting high-temperature decomposition reactions and exhibiting a lower heat flow during electrochemical cycling.

25 ENERGY STORAGE↗

NASA Electric Aircraft Test Bed (NEAT) Development Plan - Design, Fabrication, Installation

As large airline companies compete to reduce emissions, fuel, noise, and maintenance costs, it is expected that more of their aircraft systems will shift from using turbofan propulsion, pneumatic bleed power, and hydraulic actuation, to instead using electrical motor propulsion, generator power, and electrical actuation. This requires new flight-weight and flight-efficient powertrain components, fault tolerant power management, and electromagnetic interference mitigation technologies. Moreover, initial studies indicate some combination of ambient and cryogenic thermal management and relatively high bus voltages when compared to state of practice will be required to achieve a net system benefit. Developing all these powertrain technologies within a realistic aircraft architectural geometry and under realistic operational conditions requires a unique electric aircraft testbed. This report will summarize existing testbed capabilities located in the U.S. and details the development of a unique complementary testbed that industry and government can utilize to further mature electric aircraft technologies.

Hybrid Electric↗

Pressure-Fed LOX/LCH4 Reaction Control System for Spacecraft: Transient Modeling and Thermal Vacuum Hotfire Test Results

An integrated cryogenic liquid oxygen, liquid methane (LOX/LCH4) reaction control system (RCS) was tested at NASA Glenn Research Center's Plum Brook Station in the Spacecraft Propulsion Research Facility (B-2) under vacuum and thermal vacuum conditions. The RCS is a subsystem of the Integrated Cryogenic Propulsion Test Article (ICPTA), a pressure-fed LOX/LCH4 propulsion system composed of a single 2,800 lbf main engine, two 28 lbf RCS engines, and two 7 lbf RCS engines. Propellants are stored in four 48 inch diameter 5083 aluminum tanks that feed both the main engine and RCS engines in parallel. Helium stored cryogenically in a composite overwrapped pressure vessel (COPV) flows through a heat exchanger on the main engine before being used to pressurize the propellant tanks to a design operating pressure of 325 psi. The ICPTA is capable of simultaneous main engine and RCS operation. The RCS engines utilize a coil-on-plug (COP) ignition system designed for operation in a vacuum environment, eliminating corona discharge issues associated with a high voltage lead. There are two RCS pods on the ICPTA, with two engines on each pod. One of these two engines is a heritage flight engine from Project Morpheus. Its sea level nozzle was removed and replaced by an 85:1 nozzle machined using Inconel 718, resulting in a maximum thrust of 28 lbf under altitude conditions. The other engine is a scaled down version of the 28 lbf engine, designed to match the core and overall mixture ratios as well as other injector characteristics. This engine can produce a maximum thrust of 7 lbf with an 85:1 nozzle that was additively manufactured using Inconel 718. Both engines are film-cooled and capable of limited duration gas-gas and gas-liquid operation, as well as steady-state liquid-liquid operation. Each pod contains one of each version, such that two engines of the same thrust level can be fired as a couple on opposite pods. The RCS feed system is composed of symmetrical 3/8 inch lines that tap off of the main propellant manifold to send LOX and LCH4 outboard to the RCS pods. A Thermodynamic Vent System (TVS) is used to condition propellants at each pod by venting through an orifice and then routing the cold expansion products back through tubing that is welded along a large portion of the main RCS feed lines. Prior to final installation on the ICPTA, the RCS engines were tested in a small vacuum chamber at the Johnson Space Center (JSC) Energy Systems Test Area (ESTA) to verify functionality of the new COP ignition system and check out operation of the vacuum nozzles. After engine-level testing, the RCS engines were installed on the vehicle and a series of integrated hot-fire tests were performed at JSC consisting of various pulsing and steady-state firings as well as integrated main engine/RCS operation. The ICPTA was then integrated into the Plum Brook B-2 facility for vacuum and thermal/vacuum testing. Testing in the B-2 facility was composed of multiple thermal and pressure environments. The first set of tests were performed under ambient temperature and altitude pressure conditions. These tests consisted of a range of minimum impulse bit (MIB) pulsing sequences with low duty cycle, analogous to a coast phase in which the RCS is primarily used for station keeping. The primary goal of this sequence is to understand how propellant conditions were effected without an active TVS. In this scenario, consistent gas-gas operation is desirable since it results in a smaller MIB and more efficient propellant consumption. Multiple skin thermocouples are mounted on the feedlines, in addition to a submerged thermocouple on each commodity, in order to gather thermal data on the system. Higher duty cycle pulsing tests were then performed, analogous to an ascent or landing mission phase. The primary goal of this sequence was to examine how well the engines self-conditioned without active TVS when starting from a quiescent state. The TVS was then activated during some tests to demonstrate the capability to quickly condition the engines for higher pulsing demand scenarios. A thermocouple at the TVS outlet allows for the calculation of energy absorbed by the vented propellant. Lastly, tests with longer pulses and multiple engines firing either in sequence or simultaneously were run in order to gather transient system response data on waterhammer. Six total high-speed pressure transducers are installed on the RCS system, one sensor at the end of each propellant manifold line on the pods, and one at the tap-off location for each commodity. This will allow for the accurate characterization of waterhammer in the system under various propellant conditions and firing sequences. Other instrumentation for this test series includes nozzle throat thermocouples, chamber pressure measurement, heat soakback measurement, and tank wall plume impingement temperature measurement. The next set of tests were performed to demonstrate simultaneous main engine and RCS operation. Data from this test will be used to examine if there is any change to nominal operation of the RCS as a result of feed system interaction or other phenomenon. Some of these tests began under high vacuum conditions (target ambient pressure less than 1x10(exp -3) torr) and others began at altitude conditions. The last set of tests were performed with the B-2 cold wall active. Under these tests, many of the same low duty cycle MIB tests were repeated in order to characterize how propellant conditions changed with the lower heat leak. In this scenario the RCS manifold experiences much less heat leak, resulting in a change to how well the engines self-condition. As a result, an increase in maximum waterhammer pressures and a change in natural frequency of the system was expected due to higher density propellants. The lower heat leak should also result in a change to the MIB pulse profile, and data will be examined to understand how MIB repeatability is affected in the different operating environments. Parallel to the test efforts, a set of transient model development efforts were made to predict RCS performance. The primary effort was aimed at producing a SINDA/FLUINT model to predict propellant conditioning up to the engine inlet as a function of different environmental and operating parameters, with the goal of predicting chamber pressure, TVS performance, and propellant consumption over time. Preliminary results for this effort will be presented in comparison with test data. Additional modeling efforts were made using SINDA/FLUINT to predict waterhammer in the system since the software is capable of handling multiphase transient fluid dynamics. These results will be compared with the high-speed pressure transducer test data for validation purposes.

Atwell, Matthew J.↗

Characterization of Avalanche Photodiodes (APDs) for the Electromagnetic Calorimeter in the ALICE Experiment

The Electromagnetic Calorimeter (EMCal) of the ALICE experiment at LHC will extensively make use of avalanche photodiodes (APDs) for the readout of scintillation light. The large sensitive area, high quantum efficiency and low dark current make this type of photosensors well-suited for the EMCal requirements. A testing activity is currently in progress in order to characterize the main properties of these APDs and find the best working conditions. Fundamental tasks are the individual test of all APDs after presetting their nominal gain via the bias control and the study of APD gain coefficients as a function of the applied bias voltage and temperature. An overview of the adopted procedure will be presented, together with a description of preliminary results obtained on a first sample of APDs during the testing activity.

43 PARTICLE ACCELERATORS↗

High Bandwidth Differential Amplifier for Shock Experiments

We developed a high bandwidth differential amplifier for gas gun shock experiments. The circuit has a bandwidth up to 1 GHz, and is capable of measuring signals of ≤1.5 V with a common mode rejection of 250 V. Conductivity measurements of gas gun targets are measured by flowing high currents through the targets. The voltage is measured across the target using a technique similar to a four-point probe. Because of the design of the current source and load, the target voltage is approximately 250 V relative to ground. Since the expected voltage change in the target is < 1 V, the differential amplifier must have a large common mode rejection. Various amplifying designs are shown, although the increased amplification decreases bandwidth. Bench tests show that the amplifier can withstand significant common mode DC voltage and measure 10 ns, and 50 mV signals.

42 ENGINEERING↗

Phasor-Based Adaptive Control of a Test-Feeder Distribution Network

Control in the power distribution system is needed to match the generation of electricity (that is, supply) with the demand for power (that is, load) at all times while maintaining a high level of power quality [1] (see "Summary"). The complexity of controlling the electric distribution system increases when distributed intermittent energy sources, such as solar photovoltaics (PVs), displace large-scale dispatchable generation [2]-[10]. Furthermore, if the supply from distributed resources exceeds the time-varying demand across a feeder, then the feeder-level voltage will increase. In extreme cases, large voltage increases will trigger the disconnection of distributed generation to protect electrical equipment and ensure customer safety. Consequently, coordinating renewable energy sources that are distributed throughout the distribution system-to match real-time demand across an entire power network-brings the additional challenge of maintaining a high level of supply reliability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

State-of-the-Art Medium- and High-Voltage Silicon Carbide Power Modules, Challenges and Mitigation Techniques: A Review

Silicon carbide (SiC) power modules have been demonstrated potential for improving power density and efficiency for low-voltage power electronics systems. This has resulted in a paradigm shift toward development of medium-voltage and high-voltage (MV/HV) SiC power modules to revolutionize the future power grid and transportation systems. However, designing MV/HV SiC power modules involves significant design challenges due to higher blocking voltage and exacerbation of side effects due to high switching dv/dt and di/dt of SiC devices-concerns that may not be as critical as in low-voltage module development. This article reviews the development of state-of-the-art MV/HV SiC power modules, ranging from 3.3 kV to 40 kV, from both industry and academia. First, a discussion on SiC modules based on voltage level is presented. This is followed by a discussion of challenges associated with designing and testing MV/HV modules- including parasitic controls, electromagnetic interference (EMI), partial discharge, and thermal management-and the corresponding mitigation approaches from various perspectives. We conclude with a summary of major findings and future directions for the development of MV/HV modules.

EMI↗

Common Mode Voltage Compensation for Capacitor Voltage Ripple Reduction of 7-kV SiC-based Modular Multilevel Converter

Abstract -Modular multilevel converters (MMCs), with the filterless and transformer-less features, are considered as a promising topology for high-efficiency medium voltage (MV) high voltage (HV) drive systems. However, a large current ripple flowing through the capacitors of each submodule will cause significant capacitor voltage fluctuation. This paper proposes a new compensation method in common mode voltage injection to further reduce the magnitude of the fundamental component in capacitor voltages. The capacitor voltage ripples are reduced significantly by using the proposed control method, which means that smaller size of capacitors can be used for same voltage ripple requirements. Simulation and experimental test results verify the proposed compensation method using a three-phase permanent magnet synchronous machine (PMSM).

Common mode voltage injection↗

Investigating the Performance of SF6 Replacement Gases to Enable the Next Generation of Pulsed Power

High voltage switches are essential components in pulsed power systems, where consistent and reliable performance is crucial—particularly as the field explores alternatives to SF 6 as an insulating gas. This project examines the self-break voltage distributions of various gases, with a focus on the low-voltage discharges observed in the lower tail of these distributions. Experimental results revealed that the specific housing design influenced the self-break behavior. Among the tested gases, air demonstrated a more favorable overall distribution compared to SF 6 , albeit requiring higher operating pressures. However, air also exhibited a greater likelihood of extremely low-voltage dropouts, raising concerns about its suitability as a direct replacement for SF 6 . Notably, all gases tested showed a higher-than-expected probability of low-voltage events when considering the tail of the distribution rather than the bulk behavior.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quench Propagation On Rare-Earth Barium Copper Oxide (REBCO) Tape

Rare-earth barium copper oxide (REBCO) high-temperature superconductors can carry high currents with zero electrical resistance, enabling applications in high-field magnets, energy systems, and fusion devices. However, localized losses of superconductivity, known as quenches, pose a severe risk due to REBCO’s mechanical brittleness and slow quench propagation, complicating early detection. This work investigates quench propagation and thermal response through controlled experiments. A segmented REBCO tape soldered onto a printed circuit board (PCB) with multiple voltage taps and temperature sensors was submerged in liquid nitrogen at 77 K. In the first test, current ramping produced a quench near 360 A, consistent with theoretical current limits, but resulted in local burnout. In the second test, a heater-induced quench at 300 A propagated bidirectionally with velocities ranging from 164–226 mm/s. These results provide critical parameters for improving REBCO quench detection and protection system design while accounting for REBCO’s limited bendability.

Ju, Han [Northern Illinois U.]↗

Local Dynamic Reactive Power for Correction of System Voltage Problems

Distribution systems are experiencing outages due to a phenomenon known as local voltage collapse. Local voltage collapse is occurring in part because modern air conditioner compressor motors are much more susceptible to stalling during a voltage dip than older motors. These motors can stall in less than 3 cycles (.05s) when a fault, such as on the sub-transmission system, causes voltage to sag to 70 to 60%. The reasons for this susceptibility are discussed in the report. During the local voltage collapse, voltages are depressed for a period of perhaps one or two minutes. There is a concern that these local events are interacting together over larger areas and may present a challenge to system reliability. An effective method of preventing local voltage collapse is the use of voltage regulation from Distributed Energy Resources (DER) that can supply or absorb reactive power. DER, when properly controlled, can provide a rapid correction to voltage dips and prevent motor stall. This report discusses the phenomenon and causes of local voltage collapse as well as the control methodology we have developed to counter voltage sag. The problem is growing because of the use of low inertia, high efficiency air conditioner (A/C) compressor motors and because the use of electric A/C is growing in use and becoming a larger percentage of system load. A method for local dynamic voltage regulation is discussed which uses reactive power injection or absorption from local DER. This method is independent, rapid, and will not interfere with conventional utility system voltage control. The results of simulations of this method are provided. The method has also been tested at the ORNL s Distributed Energy Communications and Control (DECC) Laboratory using our research inverter and synchronous condenser. These systems at the DECC Lab are interconnected to an actual distribution system, the ORNL distribution system, which is fed from TVA s 161kV sub-transmission backbone. The test results are also provided and discussed. The simulations and testing show that local voltage control from DER can prevent local voltage collapse. The results also show that the control can be provided so quickly, within 0.5 seconds, that is does not interfere with conventional utility methods.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of a stable electro-optical modulator

The activity of the sun can be studied through the measurement of its magnetic field. The measurement of the polarization state of the sunlight in a narrow spectral bandwidth can be related to the magnetic fields strengths and directions over the active sunspots. Measuring the polarization state can be done using the vector magnetograph. The essential component of the vector magnetograph is the polarization modulators. Electro-optical modulators are used as dynamic retarders. KDP (potassium dideuterium phosphate) crystals provide variable retardation which can be controlled by the applied voltage. KDP's have a high contrast ratio but suffer some problems; they require a high voltage and have a limited modulation lifetime. The KDP modulator forms the heart of the polarimeter assembly which is used for carrying out accurate measurements of linear polarization of the sun. It is therefore important to study the optical and electrical behavior of the KDP crystals so that the ultimate goal of making stable electro-optical modulators in the laboratory is achieved. A number of activities were performed in coating and testing the KDP crystals. A summary of these activities is given.

Abushagur, Mustafa A. G.↗

Survey of Experimental Results From One Year of PASP PLUS Orbital Operation

With PASP Plus as its primary payload, the APEX satellite was launched by a standard Pegasus rocket released from a NASA B-52 aircraft on 3 August 1994. A 70 deg inclination, 363 km X 2550 km orbit was achieved, allowing both investigation of space plasma effects on high-voltage operation in the perigee region and investigation of space radiation effects on array power output from passage through the inner radiation belt in the apogee region. Data gathering by PASP Plus was begun on 7 Aug 94 and ended on 11 Aug 95. In one year, PASP Plus collected an order of magnitude more data on environmental interactions on solar arrays than all previous space-borne photovoltaic experiments combined. The test arrays flown and the interactions-measuring and space-environment sensors of PASP Plus are described. The results of measurements of leakage current under test-array positive biasing and arc rates under negative biasing as a function of bias voltage, plasma density, array orientation, and other conditions are presented. The results of measurements of test-array power-output degradation caused by space radiation are also examined.

PHOTOVOLTAIC EFFECT↗

Effects of Surface Oxygen on the Performance of Carbon as an Anode in Lithium-Ion Batteries

Carbon materials with similar bulk structure but different surface oxygen were compared for their performance as anodes in lithium-ion battery. The bulk structure was such that the graphene planes were perpendicular to the surface. Three types of surfaces were examined: surface containing C=O type oxygen. surface containing -O-C type oxygen, and surface containing high concentration of active sites. The test involved cycles of lithium insertion into and release from the carbon materials, which was in the half cells of carbon/saturated LiI-50/50 (vol %) EC and DMC/lithium. During the first cycle of lithium insertion, the presence of adsorbed oxygen, -O-C type oxygen, active carbon sites, and C=O type oxygen resulted in the formation of solid-electrolyte interface (SEI) when the carbon's voltage relative to lithium metal was >1.35, 1 to 1.35, 0.5 to 1, and 0.67 to 0.7 V, respectively. An optimum -O-C type oxygen and a minimum C=O type oxygen was found to increase the reversible and decrease the irreversible capacity of carbon. Active sites on the carbon surface result in a large irreversible capacity and a second lithium insertion-release mechanism. However, this new mechanism has a short cycle life.

Hung, Ching-Cheh↗