Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Studies of single-photoelectron response and of performance in magnetic field of a H8500C-03 photomultiplier tube

We studied the single-photoelectron detection capabilities of a multianode photomultiplier tube H8500C-03 and its performance in high magnetic field. Our results show that the device can readily resolve signals at the single photoelectron level making it suitable for photon detection in both threshold and ring imaging Cherenkov detectors. We also found that a large longitudinal magnetic field, up to 300 Gauss, induces a change in the relative output of at most 55% for an edge pixel, and of at most 15% for a central pixel. The H8500C-03 signal loss in transverse magnetic fields it is significantly more pronounced than for the longitudinal case. Our studies of single photoelectron reduction in magnetic fields point to the field induced misfocusing of the photoelectron extracted from the photocathode as primary cause of signal loss. With appropriate shielding this PMT could function in high magnetic field environments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetic excitations from an S=1/2 diamond-shaped tetramer compound Cu 2 PO 4 OH

Inelastic neutron scattering experiments have been carried out on a powder sample of Cu 2 PO 4 OH, which consists of diamond-shaped tetramer spin units with S=1/2. We have observed two nearly dispersionless magnetic excitations at E 1 ~2 and E 2 ~0 meV, whose energy width are broader than the instrumental resolution. The simplest square tetramer model with one dominant interaction, which predicts two sharp excitation peaks at E 1 and E 2 (=2E 1 ), does not explain the experimental result. We found that two diagonal intratetramer interactions compete with the main interaction and weak intertetramer interactions connect the tetramers. The main intratetramer interaction is found to split into two inequivalent ones due to a structural distortion below 160 K. Cu 2 PO 4 OH is considered to be a good material to study the S=1/2 Heisenberg tetramer system.

36 MATERIALS SCIENCE↗

Ultrahigh Field NMR and MRI: Science at a Crossroads Workshop Report

The workshop “Ultrahigh Field NMR and MRI: Science at Crossroads”, initiated by the scientific community and supported by the National Science Foundation, the Department of Energy, and the National Institutes of Health, took place on November 12-13, 2015, in Bethesda, MD, on the NIH campus. The meeting was held to assess the science drivers, technological challenges, prospects for achieving field strengths for NMR and MRI nearly double their current value, and strategies on how to provide ultrahigh field NMR/MRI capabilities to a national user community.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultrasonic waveguide reflectometry for quench detection (CRADA Final Report)

Early detection of thermal runaway (quench) is critical for safely operating high-temperature superconductor (HTS) magnets. Voltage-based techniques provide late detection of quenching in HTS, which can lead to magnet burnout and system damage. Various non-voltage quench-detection approaches are therefore investigated nowadays that are based on magnetic, acoustic, and optical sensing. LBNL has been actively developing the quench detection principle based on diffuse ultrasonic wave propagation since 2017 and has demonstrated the approach's viability with several peer-reviewed publications and a patent application. Over the last decade, Etegent, LBNL partner for this proposal and effort, has been developing a sensing technology that utilizes the propagation of stress waves through the solid metallic and nonmetallic waveguides (WG). The method is based on the dependence of materials' elastic properties and the speed of sound on temperature. Compared with optical analog, acoustic WG operates at much lower frequencies, eliminating the need for expensive, complex, highly sensitive receivers and data processing. Etegent proved this technology in many harsh environments, mainly concentrated high-temperature measurements. The initial contact between LBNL and Etegent started in 2020, aiming at combining our knowledge and effort toward developing a viable ultrasound-based quench detection technique for use with HTS magnets. A preliminary study conducted jointly in 2022 found no principle restrictions for expanding the WG technology toward cryogenic temperature operation. The present CRADA work aimed at designing, building, and testing ultrasonic waveguide temperature sensors at relevant cryogenic conditions, and demonstrating this technology's applicability to detecting heating and quenching in High Temperature Superconductor (HTS)-based cables and magnets. The technical objectives of the project included: (1) Design and fabricate ultrasonic WG sensors suitable for cryogenic operation, (2) Test ultrasonic WGs under cryogenic conditions, (3) Determining a suitable way of insulating WGs to prevent ultrasonic leakage while maintaining good thermal contact with the surrounding medium, (4) WG integration and cryogenic test with HTS conductors and HTS magnets, and (5) Design and basic prototyping of a standalone WG-based quench detection system. This project adds value to the present LBNL magnet diagnostics portfolio and enables a breakthrough in addressing the HTS magnet quench detection challenge.

47 OTHER INSTRUMENTATION↗

Low Temperature Microcalorimeters for Decay Energy Spectroscopy

Low Temperature Detectors have been used to measure embedded radioisotopes in a measurement mode known as Decay Energy Spectroscopy (DES) since 1992. DES microcalorimeter measurements have been used for applications ranging from neutrino mass measurements to metrology to measurements for safeguards and medical nuclides. While the low temperature detectors have extremely high intrinsic energy resolution (several times better than semiconductor detectors), the energy resolution achieved in practice is strongly dependent on factors such as sample preparation method. This review seeks to present the literature consensus on what has been learned by looking at the energy resolution as a function of various choices of detector, absorber, and sample preparation methods.

47 OTHER INSTRUMENTATION↗

Development of high reliability, high frequency power conditioning models of converter regulators

High efficiency conversion, regulation, and filtering techniques are discussed for power using high conversion frequencies; i.e., in the order of 1 to 5 MHz for converters having total output power capability in the order of 20 watts and 200 to 500 KHz for converters having total output powers in excess of 200 watts. Work centered on areas of component selection, material selection, optimization of the various types of circuits required, and the selection of materials for and design of magnetic components. These techniques were then applied to the design of two sample converters, one a medium power instrument type converter and the second a high power converter representative of a primary spacecraft converter regulator. The configuration and performance of the two converters is reported and discussed.

Rochussen, A. W.↗

Force balance in the magnetospheres of Jupiter and Saturn

Spacecraft measurements of the plasma populations and magnetic fields near Jupiter and Saturn have revealed that large magnetospheres surround both planets. Magnetic field measurements have indicated closed field line topologies in the dayside magnetospheres of both planets while plasma instruments have shown these regions to be populated by both hot and cold plasma components convected azimuthally in the sense of planetary rotation. By using published data from the Voyager Plasma Science (PLS), Low Energy Charged Particle (LECP), and Magnetometer (MAG) instruments, it is possible to investigate the validity of the time stationary MHD momentum equation in the middle magnetospheres of Jupiter and Saturn. At Saturn, the hot plasma population is negligible in the dynamic sense and the centrifugal force of the cold rotating plasma appears to balance the Lorentz force. At Jupiter, the centrifugal force balances about 25 percent of the Lorentz force. The remaining inward Lorentz force is balanced by pessure gradients in the hot, high-beta plasma of the Jovian magnetodisk.

Mcnutt, R. L., Jr.↗

Particle acceleration

Data is compiled from Solar Maximum Mission and Hinothori satellites, particle detectors in several satellites, ground based instruments, and balloon flights in order to answer fundamental questions relating to: (1) the requirements for the coronal magnetic field structure in the vicinity of the energization source; (2) the height (above the photosphere) of the energization source; (3) the time of energization; (4) transistion between coronal heating and flares; (5) evidence for purely thermal, purely nonthermal and hybrid type flares; (6) the time characteristics of the energization source; (7) whether every flare accelerates protons; (8) the location of the interaction site of the ions and relativistic electrons; (9) the energy spectra for ions and relativistic electrons; (10) the relationship between particles at the Sun and interplanetary space; (11) evidence for more than one acceleration mechanism; (12) whether there is single mechanism that will accelerate particles to all energies and also heat the plasma; and (13) how fast the existing mechanisms accelerate electrons up to several MeV and ions to 1 GeV.

Vlahos, L.↗

Rendezvous with a star

The spacecraft Ulysses carrying five European and four American instruments is described. The instruments are designed to investigate the properties of the solar wind, the sun-wind interface, the heliospheric magnetic field, solar radio burst and plasma waves, solar X-rays, solar and galactic cosmic rays, and gas and dust in interplanetary space. Ulysses is scheduled to be carried into orbit aboard the Space Shuttle in October 1990, when Jupiter's position relative to the earth is suitable for a minimum-energy trajectory. Once in orbit, a three-stage, solid-fuel vehicle known as the Inertial Upper Stage plus Payload Assist Module (Special), will then propel Ulysses on a 16-month journey to Jupiter. In February 1992, Ulysses is scheduled to fly past Jupiter toward its rendezvous with the sun. Ulysses will then head for a region of interplanetary space never before explored and is scheduled to have two solar encounters. Its official mission ends soon after September 1995.

Bennett, Gary L.↗

Experimental radiation cooled magnetrons for space

The heat disposal problem that occurs in the microwave generator of the Solar Power Satellite when it converts dc power from solar photovoltaic arrays into microwave power for transmission to earth is examined. A theoretical study is made of the radiation cooling of a magnetron directional amplifier, and some experimental data obtained from the QKH 2244 magnetron are presented. This instrument is an unpackaged microwave oven magnetron to which an anodized aluminum radiator has been attached and whose magnetic field is supplied by special samarium cobalt magnets.

Brown, W. C.↗

Active region studies with coordinated SOHO, microwave, and magnetograph observations

The scientific justification for an observing campaign to study the quantitative magnetic and plasma properties of coronal loops in active regions is presented. The SOHO (Solar and Heliospheric Observatory) instruments of primary relevance are CDS (Coronal Diagnostic Spectrometer), EIT, SUMER (Solar Ultraviolet Measurement of Emitted Radiation), and MDI. The primary ground based instruments would be the VLA (Very Large Array), the Owens Valley Radio Observatory, and vector and longitudinal field magnetographs. Similar campaigns have successfully been carried out with the Solar Maximum Mission x-ray polychromator and the Soft X-ray Imaging Sounding Rocket Payload (CoMStOC '87), the Goddard Solar EUV Rocket Telescope and Spectrograph, the Lockheed Solar Plasma Diagnostics Experiment rocket payload, and the Soft X-ray Telescope in Yohkoh (CoMStoc '92). The scientific payoff from such a campaign is discussed in light of the results from these previous campaigns.

Holman, Gordon D.↗

Development of a large field-of-view KD potassium di-deuterium phosphate modulator: Center Director's Discretionary Fund

Magnetographs, which measure polarized light, allow solar astronomers to infer the magnetic field intensity on the Sun. The Marshall Space Flight Center (MSFC) Vector Magnetograph is such an imaging instrument. The instrument requires rapid modulation between polarization states to minimize seeing effects. The accuracy of those polarization measurements is dependent on stable modulators with small field-of-view errors. Although these devices are very important in ground-based telescopes, extending the field of view of electro-optical crystals such as KD*Ps (potassium di-deuterium phosphate) could encourage the development of these devices for other imaging applications. The work that was done at MSFC as part of the Center Director's Discretionary Fund (CDDF) to reduce the field-of-view errors of instruments that use KD*P modulators in their polarimeters is described.

West, E. A.↗

Microactuator production via high aspect ratio, high edge acuity metal fabrication technology

LIGA is a procession sequence which uses x-ray lithography on photoresist layers of several hundred micrometers to produce very high edge acuity photopolymer molds. These plastic molds can be converted to metal molds via electroplating of many different metals and alloys. The end results are high edge acuity metal parts with large structural heights. The LIGA process as originally described by W. Ehrfeld can be extended by adding a surface micromachining phase to produce precision metal parts which can be assembled to form three-dimensional micromechanisms. This process, SLIGA, has been used to fabricate a dynamometer on a chip. The instrument has been fully implemented and will be applied to tribology issues, speed-torque characterization of planar magnetic micromotors and a new family of sensors.

Guckel, H.↗

The Three-Dimenstional Solar Wind at Solar Activity Minimum

In late 1997, the Ulysses spacecraft completed its first orbit around the Sun, observing the properties of the heliosphere at all latitudes between 80 degrees South and 80 degrees North. Because the mission occurred during a period of near-minimum solar activity, the configuration of the solar wind and interplanetary magnetic field were particularly simple, thus allowing confident comparisons between the properties of the polar corona observed by instruments of the Spartan and SOHO spacecraft and the resulting properties of the solar wind.

Solar Wind Ulysses Solar Activity polar corona↗

Polarization Measurements on SUMI's TVLS Gratings

We present measurements of toroidal variable-line-space (TVLS) gratings for the Solar Ultraviolet Magnetograph Investigation (SUMI), currently being developed an the National Space Science and Technology Center (NSSTC). SUMI zs a spectro-polarimeter designed no measure magnetic fields in the solar chromosphere by observing two UV emission lines sensitive to magnetic fields, the C-IV line at 155nm and the Mg-II line at 280nm. The instrument uses a pair of TVLS gratings, to observe both linear polarizations simultaneously. Efficiency measurements were done on bare aluminum gratings and MgF2 coated gratings, at both linear polarizations.

Kobayashi, K.↗

Nondestructive Crack Detection in a Fuel System Component

The paper discusses development of various NDE techniques to detect cracks in A40 steel poppets used in a valve of the fuel system of the Space Shuttle Orbiter. The valve assembly experiences a severe high cycle fatigue environment during its operation. Cracks were discovered at the radius of the poppet flange. Experience shows that very small cracks or material anomalies do not cause failure in a single operation event. While the design is being modified to eliminate the issue, NDE has been used to screen the poppets for cracks before every use. Several surface flaw detection techniques were considered and a few NDE techniques were developed to provide NDE screening for the flaw detection. The primary method used was the eddy current testing. In the eddy current technique, the X-Y channel test data from the eddy current instrument was recorded as computer files. A Matlab data review and plotting application was developed to analyze the data files. The Matlab application provides much higher resolution than the eddy current instrument that was used to acquire the data. Other techniques that were used included ultrasonic surface wave and magnetic particle testing. A probability of detection (POD) study was undertaken to determine the 90/95 size for the eddy current technique. This study used specimens with same geometry and material as the poppet. Fatigue cracks were grown in these specimens. Information on results of the NDE techniques and results of the POD study are provided.

Koshti, Ajay↗

Thermal Testing and Model Correlation of the Magnetospheric Multiscale (MMS) Observatories

International Conference on Envronmental Systems (ICES), Seattle WA NCTS 20964-15. The Magnetospheric Multiscale (MMS) mission is a Solar Terrestrial Probes mission comprising four identically instrumented spacecraft that will use Earths magnetosphere as a laboratory tostudy the microphysics of three fundamental plasma processes: magnetic reconnection, energetic particle acceleration, and turbulence. This paper presents the complete thermal balance (TB) test performed on the first of four observatories to go through thermal vacuum (TV) and the minibalance testing that was performed on the subsequent observatories to provide a comparison of all four. The TV and TB tests were conducted in a thermal vacuum chamber at the Naval Research Laboratory (NRL) in Washington, D.C. with the vacuum level higher than 1.3 x 10-4 Pa (10-6 torr)and the surrounding temperature achieving -180 C. Three TB test cases were performed that included hot operational science, cold operational science and a cold survival case. In addition to the three balance cases a two hour eclipse and a four hour eclipse simulation was performed during the TV test to provide additional transient data points that represent the orbit in eclipse (or Earth's shadow) The goal was to perform testing such that the flight orbital environments could be simulated as closely as possible. A thermal model correlation between the thermal analysis and the test results was completed. Over 400 1-Wire temperature sensors, 200 thermocouples and 125 flight thermistor temperature sensors recorded data during TV and TB testing. These temperatureversus time profiles and their agreements with the analytical results obtained using Thermal Desktop and SINDAFLUINT are discussed. The model correlation for the thermal mathematical model (TMM) is conducted based on the numerical analysis results and the test data. The philosophy of model correlation was to correlate the model to within 3 C of the test data using the standard deviation and mean deviation error calculation. Individual temperature error goal is to be within 5 C and the heater power goal is to be within 5 of test data. The results of the model correlation are discussed and the effect of some material and interface parameters on the temperature profiles are presented.

Thermal↗