Operation and maintenance, fire rescue air-pack. Volume 2: Communications

The operation and maintenance procedures are described for the development model of the fire rescue air pack (FRAP) voice amplifier assembly, including the battery charger. Operational instructions include a general description of the assembly, specifications, and installation and operation. Maintenance instructions include theory of operation, preventive maintenance, repair, adjustment, and a parts list. The FRAP is intended to permit fire rescue personnel to enter a smoke-filled, toxic or oxygen depleted environment carrying their own source of breathing air. The voice amplifier assembly permits the wearer to communicate by voice with other persons in the vicinity. The battery charger assembly provides a means of keeping the amplifier batteries fully charged.

Source record↗

Development of a self-priming high-capacity heat pipe for flight on OAO-C.

This paper describes the development of a 0.500-inch OD heat pipe with a spiral artery designed to fill under surface tension forces in a one-g field. Capacities in excess of 12,000 watt-inches have been achieved with ammonia as the working fluid. The paper presents the analysis, design, and test of the three-foot-long development models. Also included are some design and fabrication details, along with qualification ground test data for a 12-foot-long spiral artery isothermalizer type heat pipe that is installed on the Orbiting Astronomical Observatory C Model scheduled for launch in 1972.

Edelstein, F.↗

Hydrogen film/conductive cooling

Small scale nozzle tests using heated nitrogen were run to obtain effectiveness and wall heat transfer data with hydrogen film cooling. Effectiveness data are compared with an entrainment model developed from planar, unaccelerated flow data. Results indicate significant effects due to flow turning and acceleration. With injection velocity effects accounted for explicitly, heat transfer correlation coefficients were found to be the same with and without film cooling when properties are evaluated at an appropriate reference temperature for the local gas composition defined by the coolant effectiveness. A design study for an O2/H2 application with 300 psia (207 N/sq cm) chamber pressure and 1500 lbs (6670 N) thrust indicates an adiabatic wall design requires 4 to 5 percent of the total flow as hydrogen film cooling. Internal regenerative cooling designs were found to offer no reduction in coolant requirements.

Ewen, R. L.↗

Elliptical storm cell modeling of digital radar data

A model for spatial distributions of reflectivity in storm cells was fitted to digital radar data. The data were taken with a modified WSR-57 weather radar with 2.6-km resolution. The data consisted of modified B-scan records on magnetic tape of storm cells tracked at 0 deg elevation for several hours. The MIT L-band radar with 0.8-km resolution produced cross-section data on several cells at 1/2 deg elevation intervals. The model developed uses ellipses for contours of constant effective-reflectivity factor Z with constant orientation and eccentricity within a horizontal cell cross section at a given time and elevation. The centers of the ellipses are assumed to be uniformly spaced on a straight line, with areas linearly related to log Z. All cross sections are similar at different heights (except for cell tops, bottoms, and splitting cells), especially for the highest reflectivities; wind shear causes some translation and rotation between levels. Goodness-of-fit measures and parameters of interest for 204 ellipses are considered.

Altman, F. J.↗

Equations for the kinetic modeling of supersonically flowing electrically excited lasers

The equations for the kinetic modeling of a supersonically flowing electrically excited laser system are presented. The work focuses on the use of diatomic gases, in particular carbon monoxide mixtures. The equations presented include the vibrational rate equation which describes the vibrational population distribution, the electron, ion and electronic level rate equations, the gasdynamic equations for an ionized gas in the presence of an applied electric field, and the free electron Boltzmann equation including flow and gradient coupling terms. The model developed accounts for vibration-vibration collisions, vibration-translation collisions, electron-molecule inelastic excitation and superelastic de-excitation collisions, charge particle collisions, ionization and three body recombination collisions, elastic collisions, and radiative decay, all of which take place in such a system. A simplified form of the free electron Boltzmann equation is developed and discussed with emphasis placed on its coupling with the supersonic flow. A brief description of a possible solution procedure for the set of coupled equations is then discussed.

Lind, R. C.↗

Measurements of the performance of multiwire proportional chambers

Data are presented that may be useful in formulating engineering specifications and test procedures for the proportional counter hodoscope to be flown as part of the High Energy Cosmic Ray Experiment on the High Energy Astronomy Observatory (HEAO), Mission A. A collection of preliminary data taken in laboratory tests of multiwire counters with an anode wire spacing of 5 mm and cathode gap spacing of 1 cm is presented. The data are from laboratory development models or counters for balloon flights and were selected to illustrate several aspects of proper and improper counter performance. Most of the data were taken from a large proportional counter hodoscope which has an active area of 0.5 by 0.5 m and 104 wires per plane.

Austin, R. W.↗

Design of a terminal pointer hand controller for teleoperator applications

The design is described of a hand controller intended to achieve the highest possible compatibility with the hand of the human operator in a teleoperator system. Concepts drawings and model development are discussed along with the development of a prototype, and the mathematical control laws.

Saenger, E. L.↗

Dynamic analysis of gas-core reactor system

A heat transfer analysis was incorporated into a previously developed model CODYN to obtain a model of open-cycle gaseous core reactor dynamics which can predict the heat flux at the cavity wall. The resulting model was used to study the sensitivity of the model to the value of the reactivity coefficients and to determine the system response for twenty specified perturbations. In addition, the model was used to study the effectiveness of several control systems in controlling the reactor. It was concluded that control drums located in the moderator region capable of inserting reactivity quickly provided the best control.

Turner, K. H., Jr.↗

An integral turbulent kinetic energy analysis of free shear flows

Mixing of coaxial streams is analyzed by application of integral techniques. An integrated turbulent kinetic energy (TKE) equation is solved simultaneously with the integral equations for the mean flow. Normalized TKE profile shapes are obtained from incompressible jet and shear layer experiments and are assumed to be applicable to all free turbulent flows. The shear stress at the midpoint of the mixing zone is assumed to be directly proportional to the local TKE, and dissipation is treated with a generalization of the model developed for isotropic turbulence. Although the analysis was developed for ducted flows, constant-pressure flows were approximated with the duct much larger than the jet. The axisymmetric flows under consideration were predicted with reasonable accuracy. Fairly good results were also obtained for the fully developed two-dimensional shear layers, which were computed as thin layers at the boundary of a large circular jet.

Peters, C. E.↗

A model for the polar transition layer and corona for November 1967.

A model for the chromospheric-coronal transition layer and lower corona has been constructed for the south polar region. EUV observations acquired by the Harvard OSO-4 experiment in the fall of 1967 were used in the analysis. The observations can be explained with a simple model consisting of two types of regions. One region has a temperature-density structure similar to that in models developed for typical equatorial quiet areas. The other region has a corona in which the temperature and density are a factor of about 2 lower and the chromospheric-coronal temperature gradient is less steep by a factor of 4.

Withbroe, G. L.↗

Research on infrared astrophysics and X ray and XUV astronomy

The infrared research was divided into two related subjects, observations at wavelengths less than 34 microns and millimeter wavelength observations. A new complex of infrared sources in the Orion Nebula observed along with a broad range of galactic and extragalactic objects. The Comet Kohoutek was measured in the 1-20 micron wavelength region and its thermal properties agreed closely with those of Comet Ikeya-Seki. Combined infrared and photoelectric studies of the Makarian galaxies showed them to have a composite spectrum with a large emission feature in the far infrared. The development of one millimeter photometry and composited bolometers is described. A technique of reconstructing two dimensional surface brightness distributions with appropriate errors from individual strip scans was developed. Model parameters were determined by fitting data in non-linear systems. Results show spectral parameter uncertainties are underestimated or incorrectly evaluated in most studies.

Source record↗

Development of a uninterrupted power system: ac and dc to dc converter

This program covered the design, fabrication and testing of an advanced development model uninterrupted power system. The input and output requirements imposed on the power processor were specified such that the unit is electrically interchangeable with existing power systems used by the Federal Aviation Administration in installations which have a history of failure due to electrical transient conditions. Input power is from either of two single-phase ac power sources or batteries with electronic selection and transfer between power sources. Battery reconditioning is automatic when either ac source is present. The output power is rated at 84OW; the nominal output is 24V at 35A. Within the 84OW limit, the regulated output voltage is adjustable from 22V to 30Vdc. Protection against continuous overloading or short circuit is provided. The unit is packaged in a standard 19-inch rack mount configuration with 7-inch panel height. Controls are on the front panel with power input and output through connectors on the rear surface. Cooling is by free convection from fin areas located on the side and rear panels. The packaged unit weighs 52.8 lbs., which can be reduced significantly if a three-phase ac power source is used.

Cronin, D. L.↗

Asymmetrical booster ascent guidance and control system design study. Volume 1: Summary

Dynamics and control, stability, and guidance analyses are summarized for the asymmetrical booster ascent guidance and control system design studies, performed in conjunction with space shuttle planning. The mathematical models developed for use in rigid body and flexible body versions of the NASA JSC space shuttle functional simulator are briefly discussed, along with information on the following: (1) space shuttle stability analysis using equations of motion for both pitch and lateral axes; (2) the computer program used to obtain stability margin; and (3) the guidance equations developed for the space shuttle powered flight phases.

Williams, F. E.↗

A parameterization for the absorption of solar radiation in the earth's atmosphere

A method is described for rapidly computing the amount of solar energy absorbed at the earth's surface and in the atmosphere as a function of altitude. The method is a parametric treatment, but the form of the solution and the coefficients involved are based on accurate multiple-scattering computations. In this treatment the absorption varies with the amount and type of clouds, the humidity, the zenith angle of the sun, and the albedo of the earth's surface. Within the stratosphere the absorption also depends on the vertical distribution of ozone. This parameterization for solar radiation is being used in current versions of the global atmospheric circulation model developed at the Goddard Institute for Space Studies.

Lacis, A. A.↗

On the formation of the lunar herringbone pattern

The V-shaped ridge components of the lunar herringbone pattern are simulated by simultaneous and nearly simultaneous impact cratering in the laboratory. The results of the simulations, together with a mathematical model developed for the case of simultaneous impacts, indicate that the pattern resulted from simultaneous impact formation of adjacent secondary craters. In addition, preliminary experimental results suggest that many secondaries of the crater Copernicus were produced by fragments that impacted either simultaneously or nearly simultaneously with the uprange fragments impacting first, at angles greater than 60 deg measured from the normal to the surface.

Oberbeck, V. R.↗

Global temperature distributions from OGO-6 6300 A airglow measurements

The OGO-6 6300 A airglow temperature measurements have been used to develop models of the global temperature distributions under solstice and equinox conditions for the altitude region from 240 to 300 km and for times ranging from dawn in this altitude region to shortly after sunset. The distributions are compared with models derived from satellite orbital decay and incoherent scatter sounding. The seasonal variation of the temperature as a function of latitude is shown to be very different from that derived from static diffusion models with constant boundary conditions.

Blamont, J. E.↗

Hydrostatics and steady dynamics of spatially varying electromechanical flow structures

The hydrostatic and steady laminar hydrodynamic equilibria of spatially varying electromechanical flow structures are investigated. Under certain conditions the relationship between the dielectric height of rise and the applied voltage is found to be double valued. It is found that one of the two equilibrium values is always unstable. This gives rise to the experimentally observed spontaneous rise of the fluid to the top of the structure, once a certain critical voltage is reached. Starting above this critical voltage with the structure completely filled and decreasing the applied voltage toward the critical value results in pinch-in failure at an intermediate point along the structure and trapping of dielectric fluid at the top. The simple mathematical model developed predicts all these phenomena, without recourse to tedious point-by-point surface force equilibrium determination. Experiments are reported which verify the results for the hydrostatic case.

Jones, T. B.↗

Analytical and experimental investigation of flow fields of annular jets with and without swirling flow

Analytical and experimental studies were performed to define the flowfield of annular jets, with and, without swirling flow. The analytical model treated configurations with variations of flow angularities, radius ratio, and swirl distributions. Swirl distributions characteristic of stator vanes and rotor blade rows, where the total pressure and swirl distributions are related were incorporated in the mathematical model. The experimental studies included tests of eleven nozzle models, both with and, without swirling exhaust flow. Flowfield surveys were obtained and used for comparison with the analytical model. This comparison of experimental and analytical studies served as the basis for evaluation of several empirical constants as required for application of the analysis to the general flow configuration. The analytical model developed during these studies is applicable to the evaluation of the flowfield and overall performance of the exhaust of statorless lift fan systems that contain various levels of exhaust swirl.