Search NASA⌕ Search

SEARCH · Search NASA

Results for “2D Image”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Multispectral Snapshot Imagers Onboard Small Satellite Formations for Multi-Angular Remote Sensing

Multispectral snapshot imagers are capable of producing 2D spatial images with a single exposure at selected, numerous wavelengths using the same camera, therefore operate differently from push broom or whiskbroom imagers. They are payloads of choice in multi-angular, multi-spectral imaging missions that use small satellites flying in controlled formation, to retrieve Earth science measurements dependent on the targets Bidirectional Reflectance-Distribution Function (BRDF). Narrow fields of view are needed to capture images with moderate spatial resolution. This paper quantifies the dependencies of the imagers optical system, spectral elements and camera on the requirements of the formation mission and their impact on performance metrics such as spectral range, swath and signal to noise ratio (SNR). All variables and metrics have been generated from a comprehensive, payload design tool. The baseline optical parameters selected (diameter 7 cm, focal length 10.5 cm, pixel size 20 micron, field of view 1.15 deg) and snapshot imaging technologies are available. The spectral components shortlisted were waveguide spectrometers, acousto-optic tunable filters (AOTF), electronically actuated Fabry-Perot interferometers, and integral field spectrographs. Qualitative evaluation favored AOTFs because of their low weight, small size, and flight heritage. Quantitative analysis showed that waveguide spectrometers perform better in terms of achievable swath (10-90 km) and SNR (greater than 20) for 86 wavebands, but the data volume generated will need very high bandwidth communication to downlink. AOTFs meet the external data volume caps well as the minimum spectral (wavebands) and radiometric (SNR) requirements, therefore are found to be currently feasible in spite of lower swath and SNR.

Nag, Sreeja↗

Computed Tomography Imaging Spectrometer (CTIS) with 2D Reflective Grating for Ultraviolet to Long-Wave Infrared Detection Especially Useful for Surveying Transient Events

The optical system of this invention is an unique type of imaging spectrometer, i.e. an instrument that can determine the spectra of all points in a two-dimensional scene. The general type of imaging spectrometer under which this invention falls has been termed a computed-tomography imaging spectrometer (CTIS). CTIS's have the ability to perform spectral imaging of scenes containing rapidly moving objects or evolving features, hereafter referred to as transient scenes. This invention, a reflective CTIS with an unique two-dimensional reflective grating, can operate in any wavelength band from the ultraviolet through long-wave infrared. Although this spectrometer is especially useful for events it is also for investigation of some slow moving phenomena as in the life sciences.

Daniel W Wilson↗

Computed tomography imaging spectrometer (CTIS) with 2D reflective grating for ultraviolet to long-wave infrared detection especially useful for surveying transient events

The optical system of this invention is an unique type of imaging spectrometer, i.e. an instrument that can determine the spectra of all points in a two-dimensional scene. The general type of imaging spectrometer under which this invention falls has been termed a computed-tomography imaging spectrometer (CTIS). CTIS's have the ability to perform spectral imaging of scenes containing rapidly moving objects or evolving features, hereafter referred to as transient scenes. This invention, a reflective CTIS with an unique two-dimensional reflective grating, can operate in any wavelength band from the ultraviolet through long-wave infrared. Although this spectrometer is especially useful for rapidly occurring events it is also useful for investigation of some slow moving phenomena as in the life sciences.

Wilson, Daniel W.↗

Evaluation of Electron Tomography Capabilities for Shale Imaging

Despite the advantageous resolution of electron tomography (ET), reconstruction of three-dimensional (3D) images from multiple two-dimensional (2D) projections presents several challenges, including small signal-to-noise ratios, and a limited projection range. This study evaluates the capabilities of ET for thin sections of shale, a complex nanoporous medium. A numerical phantom with 1.24 nm pixel size is constructed based on the tomographic reconstruction of a Barnett shale. A dataset of 2D projection images is numerically generated from the 3D phantom and studied over a range of conditions. First, common reconstruction techniques are used to reconstruct the shale structure. The reconstruction uncertainty is quantified by comparing overall values of storage and transport metrics, as well as the misclassification of pore voxels compared to the phantom. We then select the most robust reconstruction technique and we vary the acquisition conditions to quantify the effect of artifacts. We find a strong agreement for large pores over the different acquisition workflows, while a wider variability exists for nanometer-scale features. Furthermore, the limited projection range and reconstruction are identified as the main experimental bottlenecks, thereby suggesting that sample thinning, advanced holders, and advanced reconstruction algorithms offer opportunities for improvement.

3D scanning transmission electron microscopy↗

2D IR Microscopy—Technology for Visualizing Chemical Dynamics in Heterogeneous Environments (Final Technical Report)

The primary focus of this project was the design, prototype, and demonstration of a 2D IR microscope. The start date of this project was July 15, 2016 and the project end date was July 14, 2022. In the early years of this project our team designed, prototyped, and completely integrated a homebuilt microscope head with our high-repetition rate 2D IR spectrometer. Once in place our research team focused on characterizing the 2D IR microscope and using it to investigate model systems relevant to energy technologies. As part of this process, we identified two initial chemical systems to use to further develop 2D IR imaging modalities. The first chemical system developed was a room temperature ionic liquid (RTIL) electrolyte system and the second chemical system was a mixture of carbonates and salts developed as a battery electrolyte system. The completion of this project resulted in the full characterization of chemical dynamics in a bulk RTIL system and the demonstration of 2D IR imaging across the RTIL cast as a microdroplet in silicon oil. In addition, we explored the liquid structures and dynamics of organic carbonate mixtures from the vantage point of the vibrational probe, methyl thiocyanate. By the end of the project, we had moved toward in-depth studies of the organic carbonate mixtures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Vectorized Rebinning Algorithm for Fast Data Down-Sampling

A vectorized rebinning (down-sampling) algorithm, applicable to N-dimensional data sets, has been developed that offers a significant reduction in computer run time when compared to conventional rebinning algorithms. For clarity, a two-dimensional version of the algorithm is discussed to illustrate some specific details of the algorithm content, and using the language of image processing, 2D data will be referred to as "images," and each value in an image as a "pixel." The new approach is fully vectorized, i.e., the down-sampling procedure is done as a single step over all image rows, and then as a single step over all image columns. Data rebinning (or down-sampling) is a procedure that uses a discretely sampled N-dimensional data set to create a representation of the same data, but with fewer discrete samples. Such data down-sampling is fundamental to digital signal processing, e.g., for data compression applications.

Dean, Bruce↗

Flagging and Correction of Pattern Noise in the Kepler Focal Plane Array

In order for Kepler to achieve its required less than 20 PPM photometric precision for magnitude 12 and brighter stars, instrument-induced variations in the CCD readout bias pattern (our "2D black image"), which are either fixed or slowly varying in time, must be identified and the corresponding pixels either corrected or removed from further data processing. The two principle sources of these readout bias variations are crosstalk between the 84 science CCDs and the 4 fine guidance sensor (FGS) CCDs and a high frequency amplifier oscillation on less than 40% of the CCD readout channels. The crosstalk produces a synchronous pattern in the 2D black image with time-variation observed in less than 10% of individual pixel bias histories. We will describe a method of removing the crosstalk signal using continuously-collected data from masked and over-clocked image regions (our "collateral data"), and occasionally-collected full-frame images and reverse-clocked readout signals. We use this same set to detect regions affected by the oscillating amplifiers. The oscillations manifest as time-varying moir pattern and rolling bands in the affected channels. Because this effect reduces the performance in only a small fraction of the array at any given time, we have developed an approach for flagging suspect data. The flags will provide the necessary means to resolve any potential ambiguity between instrument-induced variations and real photometric variations in a target time series. We will also evaluate the effectiveness of these techniques using flight data from background and selected target pixels.

Kolodziejczak, Jeffery J.↗

First-principles simulation of light-ion microscopy of graphene

The extreme sensitivity of 2D materials to defects and nanostructure requires precise imaging techniques to verify presence of desirable and absence of undesirable features in the atomic geometry. Helium-ion beams have emerged as a promising materials imaging tool, achieving up to 20 times higher resolution and 10 times larger depth-of-field than conventional or environmental scanning electron microscopes. Here, we offer first-principles theoretical insights to advance ion-beam imaging of atomically thin materials by performing real-time time-dependent density functional theory simulations of single impacts of 10–200 keV light ions in free-standing graphene. Here we predict that detecting electrons emitted from the back of the material (the side from which the ion exits) would result in up to three times higher signal and up to five times higher contrast images, making 2D materials especially compelling targets for ion-beam microscopy. This predicted superiority of exit-side emission likely arises from anisotropic kinetic emission. The charge induced in the graphene equilibrates on a sub-fs time scale, leading to only slight disturbances in the carbon lattice that are unlikely to damage the atomic structure for any of the beam parameters investigated here.

36 MATERIALS SCIENCE↗

2D monochromatic x-ray imaging for beam monitoring of an x-ray free electron laser and a high-power femtosecond laser

Single-shot simultaneous beam monitoring of an x-ray free electron laser (XFEL) and a high-power femtosecond laser is demonstrated using 2D monochromatic Kα imaging. In a pump-probe experiment carried out at the Matter in Extreme Conditions end-station of the Linac Coherent Light Source, a thin solid titanium foil irradiated by a 25-TW relativistic intensity laser for fast electron isochoric heating was probed by a 7.0 keV XFEL beam for x-ray Thomson scattering measurements. Using a spherical crystal imager (SCI), the spatial overlap of the beams was examined by measuring 4.5 keV titanium Kα x rays produced by laseraccelerated fast electrons and the x-ray beam. Changes in XFEL-induced Kα emission patterns were observed down to a ~20×40 μm2 rectangular shape as the beam was focused. Laser-only and two-beam shots reveal that large spatial offsets of laser-induced Kα spots in a horizontal direction is attributed to imprecise target positioning rather than shot-to-shot laser pointing variations. As a consequence, successful beam overlapping was observed on ~58% of all two-beam shots for 10 μm thick samples. The Kα measurements also show a linear relationship between total Kα yields and integrated x-ray scattering signals. Monochromatic xray imaging with SCI could be used as an on-shot beam pointing diagnostic in XFEL-laser or multiple short-pulse laser experiments.

47 OTHER INSTRUMENTATION↗

Two-Dimensional Projected-Momentum Covariance Mapping for Coulomb Explosion Imaging

We introduce projected-momentum covariance mapping, an extension of recoil-frame covariance mapping for 2D ion imaging studies. By considering the two-dimensional projection of the ion momenta as recorded by the detector, one opens the door to a complex suite of analysis tools adapted from three-dimensional momentum imaging studies. This includes the use of different frames of reference to unravel the dynamics of fragmentation and the application of fragment momentum constraints to isolate specific fragmentation channels. The technique is demonstrated on data from a two-dimensional ion imaging study of the Coulomb explosion of the cis and trans isomers of 1,2-dichloroethene, following strong-field ionization by an intense near-infrared femtosecond laser pulse. Classical simulations are used to guide the interpretation of projected-momentum covariance maps. The results offer a detailed insight into the distinct Coulomb explosion dynamics for this pair of isomers and lay the groundwork for future time-resolved studies of photoisomerization dynamics in this molecular system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A prototype scintillator real‐time beam monitor for ultra‐high dose rate radiotherapy

Background: FLASH Radiotherapy (RT) is an emergent cancer RT modality where an entire therapeutic dose is delivered at more than 1000 times higher dose rate than conventional RT. For clinical trials to be conducted safely, a precise and fast beam monitor that can generate out-of-tolerance beam interrupts is required. This paper describes the overall concept and provides results from a prototype ultra-fast, scintillator-based beam monitor for both proton and electron beam FLASH applications. Purpose: A FLASH Beam Scintillator Monitor (FBSM) is being developed that employs a novel proprietary scintillator material. The FBSM has capabilities that conventional RT detector technologies are unable to simultaneously provide: (1) large area coverage; (2) a low mass profile; (3) a linear response over a broad dynamic range; (4) radiation hardness; (5) real-time analysis to provide an IEC-compliant fast beam-interrupt signal based on true two-dimensional beam imaging, radiation dosimetry and excellent spatial resolution. Methods: The FBSM uses a proprietary low mass, less than 0.5 mm water equivalent, non-hygroscopic, radiation tolerant scintillator material (designated HM: hybrid material) that is viewed by high frame rate CMOS cameras. Folded optics using mirrors enable a thin monitor profile of ∼10 cm. A field programmable gate array (FPGA) data acquisition system generates real-time analysis on a time scale appropriate to the FLASH RT beam modality: 100–1000 Hz for pulsed electrons and 10–20 kHz for quasi-continuous scanning proton pencil beams. An ion beam monitor served as the initial development platform for this work and was tested in low energy heavy-ion beams ( 86 Kr +26 and protons). A prototype FBSM was fabricated and then tested in various radiation beams that included FLASH level dose per pulse electron beams, and a hospital RT clinic with electron beams. Results: Results presented in this report include image quality, response linearity, radiation hardness, spatial resolution, and real-time data processing. Furthermore, the HM scintillator was found to be highly radiation damage resistant. It exhibited a small 0.025%/kGy signal decrease from a 216 kGy cumulative dose resulting from continuous exposure for 15 min at a FLASH compatible dose rate of 237 Gy/s. Measurements of the signal amplitude versus beam fluence demonstrate linear response of the FBSM at FLASH compatible dose rates of >40 Gy/s. Comparison with commercial Gafchromic film indicates that the FBSM produces a high resolution 2D beam image and can reproduce a nearly identical beam profile, including primary beam tails. The spatial resolution was measured at 35–40 µm. Tests of the firmware beta version show successful operation at 20 000 Hz frame rate or 50 µs/frame, where the real-time analysis of the beam parameters is achieved in less than 1 µs. Conclusions: The FBSM is designed to provide real-time beam profile monitoring over a large active area without significantly degrading the beam quality. A prototype device has been staged in particle beams at currents of single particles up to FLASH level dose rates, using both continuous ion beams and pulsed electron beams. Using a novel scintillator, beam profiling has been demonstrated for currents extending from single particles to 10 nA currents. Radiation damage is minimal and even under FLASH conditions would require ≥50 kGy of accumulated exposure in a single spot to result in a 1% decrease in signal output. Beam imaging is comparable to radiochromic films, and provides immediate images without hours of processing. Real-time data processing, taking less than 50 µs (combined data transfer and analysis times), has been implemented in firmware for 20 kHz frame rates for continuous proton beams.

2D beam imaging↗

Experimental investigation of multi-scale strain-field heterogeneity in rocks

Rocks have inherently heterogeneous micro-structures. The mechanical response of these heterogeneous micro-structures primarily governs the overall macroscopic behavior of intact rocks, as these features cause heterogeneity in the distribution of stress and strain within a rock volume. These attributes have generally been studied through numerical tools, but in this study, the stress-induced multi-scale spatial heterogeneity in the strain-field of three types of rocks was analyzed experimentally. The full-field non-contact strain measurement approach of 2D Digital Image Correlation (DIC) was employed for real-time evaluation of the progression of strain-field heterogeneity across the surface of the rock specimens when subjected to uniaxial compression. The results show that the strain-field heterogeneity is a characteristic of the inherent heterogeneity of the rock specimens, and that it amplifies with the magnitude of stress applied on the rock specimens. The changes in the strain-field heterogeneity with loading were consistent with established microcrack evolution processes in the rock specimens. The statistical fluctuation in the strain-field heterogeneity of the three rocks at varying gauge lengths (GL) was then analyzed for the determination of the Representative Volume Element (RVE) length-scale at increasing load levels. The evolution of the RVE length-scale with loading facilitates an objective way of determination of the stress at which the strain-field heterogeneity increases and begins to influence the overall global response of the material. The RVE length-scale variation with loading showed that at the RVE length-scale reaches the specimen-scale at load levels well below the peak strength.

2D-digital image correlation↗

Bragg edge imaging (BEI) of B12W and M8N socket sections of the Arecibo telescope

From neutron user principal investigator: We kindly request the public release of three neutron imaging datasets through ONCat. All datasets were collected from two forensic specimens, B12W and M8N, sectioned from zinc-filled steel-wire sockets recovered from the collapsed Arecibo Telescope. The dataset titled “Neutron radiographs of B12W and M8N socket sections of the Arecibo telescope” contains normalized two-dimensional (2D) neutron radiographs of the specimens, showing the geometry and spatial distribution of the steel wires embedded within the zinc matrix, as well as internal features such as voids and cracks. The dataset titled “Neutron computed tomography of B12W and M8N socket sections of the Arecibo telescope” contains normalized 2D neutron projection images acquired over a range of specimen rotation angles for one selected region of each specimen. These projection images were used to reconstruct three-dimensional (3D) tomographic volumes that reveal the embedded-wire geometry and internal defects. The dataset titled “Bragg edge imaging (BEI) of B12W and M8N socket sections of the Arecibo telescope” contains six time-of-flight (TOF) neutron imaging datasets, three from each specimen, acquired at regions of interest selected based on the radiographs. The spatially resolved 2D TOF images show the zinc matrix and embedded steel wires, and the wavelength-dependent neutron transmission data were used to characterize crystallographic texture within the zinc. All components and their condition are in the public domain as they are the property of the National Science Foundation (NSF). The neutron imaging data, part geometries, and detailed forensic information have been widely published in the Arecibo Telescope Collapse Forensic Report by Thornton Tomasetti Engineers and others (NASA report and NASEM report).

Bilheux, Hassina↗

Visual information processing II; Proceedings of the Meeting, Orlando, FL, Apr. 14-16, 1993

Various papers on visual information processing are presented. Individual topics addressed include: aliasing as noise, satellite image processing using a hammering neural network, edge-detetion method using visual perception, adaptive vector median filters, design of a reading test for low-vision image warping, spatial transformation architectures, automatic image-enhancement method, redundancy reduction in image coding, lossless gray-scale image compression by predictive GDF, information efficiency in visual communication, optimizing JPEG quantization matrices for different applications, use of forward error correction to maintain image fidelity, effect of peanoscanning on image compression. Also discussed are: computer vision for autonomous robotics in space, optical processor for zero-crossing edge detection, fractal-based image edge detection, simulation of the neon spreading effect by bandpass filtering, wavelet transform (WT) on parallel SIMD architectures, nonseparable 2D wavelet image representation, adaptive image halftoning based on WT, wavelet analysis of global warming, use of the WT for signal detection, perfect reconstruction two-channel rational filter banks, N-wavelet coding for pattern classification, simulation of image of natural objects, number-theoretic coding for iconic systems.

Huck, Friedrich O.↗

Updimensioning strategy derived from synthetic equiaxed grain structures for approximating 3D grain size distributions from 2D visualizations with 1D parameters

We generated synthetic equiaxed grain structures using computer graphics software to explore the relationship between various grain size determination methods and true three-dimensional (3D) grain diameters. Mirroring grain measurement techniques, the synthetic 3D grain structures are imaged as 2D micrographs which are measured to yield 1D grain size parameters. Synthetic grain structures provide data at a mass scale and permit exploration of both polished and fractured surface micrographs, revealing one-to-one correspondence between exposed 2D grain cross-sections and individual 3D grains. Analysis of this correspondence yielded a procedure to approximate 3D equiaxed grain size and volume distributions based on the mode of the 2D fractograph grain size distribution. The 3D approximation procedure is shown to be less susceptible to different imaging conditions that affect small, undiscernible grains compared to the standard planimetric and linear intercept methods, which by design also tend to underestimate the 3D grain diameter. The procedure requires larger sample sizes to lower variance and a deeper analysis which could become more practical with machine learning (ML) models for grain boundary segmentation, which synthetic grain structures can help train. This work lays the foundation for analyzing other grain distributions such as columnar and composite grains in similar depth.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Quantitative 2D thermometry in turbulent sooting non-premixed flames using filtered Rayleigh scattering

This paper demonstrates the application of a thermometry method in turbulent sooting non-premixed flames using filtered Rayleigh scattering (FRS). Fuel tailoring is used to establish a specific C 2 H 2 -based fuel mixture such that temperature can be determined accurately by a single FRS measurement over the entirety of mixture fraction space, or equivalently, for all relevant thermo-chemical states. Evaluation is performed in a hierarchy of flows to establish measurement precision and accuracy. Initial assessments in a series of heated fuel mixtures; non-sooting, near-adiabatic flat flames; and laminar non-premixed sooting flames show accuracy of the approach over a full range of expected temperatures and high single-shot measurement precision (e.g., 65 < <#comment/> S N R < <#comment/> 80 ) for temperatures between 1900 and 2200 K. Subsequently, 2D temperature measurements are evaluated in a turbulent non-premixed sooting flame. For the current fuel mixture, the local mixture-averaged Rayleigh scattering cross section is nearly constant over all composition space, and thus traditional laser Rayleigh scattering (LRS) is used as a measurement standard in the absence of soot. The results show excellent agreement between the proposed FRS thermometry approach and LRS in non-sooting regions. In the presence of soot, the proposed FRS-based approach shows no signs of interference. In addition, 2D temperature imaging shows high SNR (60–74) over all temperature conditions. Thus, we believe the proposed methodology successfully provides a high-resolution 2D temperature method under turbulent sooting flame conditions.

Pu, Jinpeng↗

Massive all-atom analysis of 2D materials with quantum properties (Final report)

Improvements in microscopy have enabled the acquisition of data at a scale that is difficult to process manually, making automated machine learning approaches to analyzing experimental images essential. In this project, we developed and applied machine learning (ML) workflows for atomic resolution scanning transmission electron microscopy (STEM) images. This development included improving both methodology as well as generating user-friendly codes. We developed machine learning architectures which, after training, automatically identify the location and types of defects throughout a material. We used these data to produce class-averaged images of 2D atomic coordinates with up to 0.3 pm precision, uncovering the structure and oscillations of long-range strain fields around point defects in WSe 2-2x Te 2x . We also resolved a long-standing problem in this field in the training of ML models, a lack of labeled experimental data, by developing a cycle-GAN that transformed simulated-generated labeled data into labeled data indistinguishable from experiment and therefore suitable for training. This removed the remaining parts of the ML data processing workflow where human intervention was still critical and therefore a bottleneck to working at scale. Codes have been developed and released for this full machine learning workflow. ML approaches to partially automate STEM acquisition were also developed. Finally we applied ML and other advanced data processing methods to several materials science problems in two-dimensional materials, including studying the evolution of hyperuniformity with defect concentration in WSe2, understanding phase transformations in transition metal dichalcogenides during in-situ heating in the STEM, and exploring how 2D interfaces transform from twisted into aligned structures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗