Search NASA⌕ Search

SEARCH · Search NASA

Results for “47 - OTHER INSTRUMENTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Dopant, coating, and grating effects in silica optical fibers under extreme neutron irradiation

Radiation effects on fiber Bragg gratings (FBGs) have been studied but data gaps related to the effects of displacement damage resulting from high fast neutron fluence remain. In this work, Type-I and Type-II FBGs inscribed in optical fibers with various core dopants (Ge and F) and fiber coatings (acrylate, polyimide) were monitored in situ during 75 days of neutron irradiation to a peak fast (>0.1 MeV) neutron fluence of 3 X 10 21 n fast /cm 2 . Further, the reflected intensity of the Type-I FBGs inscribed in a Ge-doped core fiber decreased by > 30 dB within 7 h of irradiation (10 19 n fast /cm 2 ), whereas Type-II FBGs inscribed in a pure silica core fiber eventually approached >40 dB attenuation after accumulating a fast neutron fluence on the order of 10 20 n fast /cm 2 . Type-II FBGs inscribed in F-doped core fiber improved stability: the attenuation approached an equilibrium value in the range of 10 to 20 dB.

47 OTHER INSTRUMENTATION↗

Tutorial: Extracting entanglement signatures from neutron spectroscopy

This tutorial is a pedagogical introduction to recent methods of computing quantum spin entanglement witnesses from spectroscopy, with a special focus on neutron scattering on quantum spin systems. We offer a brief introduction to the concepts and equations, define a data analysis protocol, and discuss the interpretation of three entanglement witnesses: one-tangle, two-tangle, and Quantum Fisher Information. We also discuss practical experimental considerations, and give three examples of extracting entanglement witnesses from experimental data: Copper Nitrate, KCuF 3 , and NiPS 3 .

47 OTHER INSTRUMENTATION↗

Comprehensive defect evaluation of advanced nuclear fuels using high-resolution acoustic signals and optimized sensor separation

Graphite pebble composite structures based on TRistructural-ISOtropic (TRISO) particles are being developed as core nuclear fuels in advanced power reactors, promising safe operation at increased temperatures. Ensuring the structural integrity of these nuclear fuels requires comprehensive and accurate non-destructive evaluation (NDE) techniques to characterize defects and damage in the pebbles. However, traditional acoustic evaluation methods face limitations in defect characterization due to the highly attenuative, and geometrically and compositionally complex nature of these structures. This study proposes an improved acoustic NDE technique for accurate detection and classification of anticipated relevant defects and damage in graphite pebbles using high-resolution acoustic signals and optimized transmit-receive sensor networks. The proposed approach utilizes a triangular three-sensor network as the base unit, comprising three transmit-receive sensors. The sensor separation distance, as well as acoustic excitation center frequency, pulse-width, and bandwidth are optimized to enhance spatial resolution and improve signal-to-noise ratio, enabling effective characterization of the smallest size and widest range of defects in pebbles. Furthermore, the use of the triangular sensor configuration instead of a more conventional transmit-receive sensor pair expands the inspection region from a one-dimensional linear path to a two-dimensional area, increasing spatial coverage. To mitigate challenges associated with processing of complex acoustic signals arising from high-frequency, high-bandwidth excitation in these structures, a machine-learning-based signal processing algorithm is integrated with the sensor network. In the machine-learning-based algorithm, multi-domain features are extracted from the acoustic signals to capture intricate signal characteristics, significantly improving defect identification and classification compared to traditional approaches. The proposed acoustic NDE technique offers considerable promise for practical and reliable defect/damage diagnostics of advanced nuclear pebble fuels.

42 ENGINEERING↗

Spectroscopic performance of Low-Gain Avalanche Diodes for different types of radiation

LGADs (Low-Gain Avalanche Diodes or Detectors) are a type of silicon Avalanche Photo-Diodes originally developed for the fast detection of minimum ionizing particles in high-energy physics experiments. Thanks to their fast timing performance, the LGAD paradigm enables detectors to accurately measure minimum ionizing particles with a timing resolution of a few tens of picoseconds. Such a performance is due to a thin substrate and the presence of a moderate signal gain. This internal gain of a few tens is enough to compensate for the reduced charge deposition in the thinner substrate and the noise of fast read-out systems. While LGADs are optimized for the detection of minimum ionizing particles for high-energy particle detectors, it is critical to study their performance for the detection of different types of particle, such as X-rays, gamma-rays, or alphas. In this paper, we evaluate the gain of three types of LGADs: two devices with different geometries and doping profiles fabricated by Brookhaven National Laboratory, and one fabricated by Hamamatsu Photonics with a different process. Since the gain in LGADs depends on the bias voltage applied to the sensor, pulse-height spectra have been acquired for bias voltages spanning from the depletion voltage up to the breakdown voltage. Finally, the signal-to-noise ratio of the generated signals and the shape of their spectra allow us to probe the underlying physics of the multiplication process.

47 OTHER INSTRUMENTATION↗

The sPHENIX Micromegas Outer Tracker

The sPHENIX Time Projection Chamber Outer Tracker (TPOT) is a Micromegas based detector. It is a part of the sPHENIX experiment that aims to facilitate the calibration of the Time Projection Chamber, in particular the correction of the time-averaged and beam-induced distortions of the electron drift. Here, this paper describes the detector mission, setup, construction, installation, commissioning and performance during the first year of sPHENIX data taking.

47 OTHER INSTRUMENTATION↗

Design of the ECCE detector for the Electron Ion Collider

The EIC Comprehensive Chromodynamics Experiment (ECCE) detector has been designed to address the full scope of the proposed Electron Ion Collider (EIC) physics program as presented by the National Academy of Science and provide a deeper understanding of the quark-gluon structure of matter. To accomplish this, the ECCE detector offers nearly acceptance and energy coverage along with excellent tracking and particle identification. The ECCE detector was designed to be built within the budget envelope set out by the EIC project while simultaneously managing cost and schedule risks. Finally, this detector concept has been selected to be the basis for the EIC project detector.

47 OTHER INSTRUMENTATION↗

Performance characterization of 5×5×12 mm 3 virtual Frisch-grid TlBr detectors

Thallium bromide (TlBr) is a promising material for semiconductor gamma-ray detectors due to its high atomic number (Tl = 81, Br = 35), high density (7.56 g/cm 3 ), and relatively low melting point (460 °C). These properties give TlBr several competitive features, including high detection efficiency, good energy resolution, and lower fabrication costs, making it suitable for applications requiring compact, highly sensitive gamma-ray detection systems. Recent developments of TlBr detectors have progressed toward thicker crystals, up to 10–20 mm, configured as pixelated or virtual Frisch-grid (VFG) devices with volumes >1 cm 3 . Despite these advances, challenges remain in practical implementation, including material and fabrication issues that affect energy resolution, device stability, performance, and longevity. These challenges are similar to those faced by HgI 2 and lead-halide perovskite detectors. Here, this study presents results from characterizing over 100 position-sensitive 5×5×12 mm 3 virtual Frisch-grid detectors fabricated by Radiation Monitoring Devices Inc. For a prototype Radioisotope Identification Device (RIID). The work identified factors limiting the performance and longevity of TlBr detectors, including stochastic response variations that limit the energy resolution to 2–3 % (at 662 keV) for most devices, performance degradation associated with defect decoration, and contact delamination. Addressing these issues advances the use of TlBr and similar materials for reliable, high-resolution gamma-ray spectroscopy.

47 OTHER INSTRUMENTATION↗

A virtual Frisch-grid geometry-based CZT gamma detector for in-field radioisotope identification

Here, we present a Virtual Frisch-Grid geometry-based CZT gamma detector developed for identifying different radioisotopes over an energy range from a few keV up to 2 MeV, and useful for efficient characterization of CZT crystals. The detector is built with a 3 x 3 matrix of CZT crystals, each measuring approximately 6 mm x 6 mm x 15 mm. The charge generated within the sensor’s active volume is read out via an anode connected directly to the AVG3_Dev integrated circuit. A current signal induced by charge drift is collected on side pads of the crystals, enabling reconstruction of a 3D interaction position. This paper discusses the design, development, and performance of the standalone, mobile detector system, which integrates the AVG3_Dev readout IC developed at Brookhaven National Laboratory, a high-speed FPGA-based with per-channel digital signal processing, and embedded system capabilities. The device is compact, battery-powered, and supports wireless data streaming, making it suitable for field operations for radioisotope identification.

47 OTHER INSTRUMENTATION↗

Algorithms for coordinate reconstruction in position-sensitive virtual Frisch-grid detectors

Arrays of position-sensitive virtual Frisch-grid (VFG) CdZnTe (CZT) detectors provide a cost-effective solution for integrating large-area arrays for gamma-ray imaging and spectroscopy. These detectors employ high-aspect ratio CZT crystals (bars) with thicknesses up to 50 mm and cross-sections of up to 10 × 10 mm 2 . Despite the long drift distances of charge carriers in such crystals, the detectors have demonstrated excellent performance, achieving energy resolutions better than 1 % full width at half maximum (FWHM) at 662 keV and 3D position resolutions finer than 1 mm. The high spatial resolution is a critical feature of these detectors, as it enables correction of response non-uniformities caused by crystal defects, which remain present even in the highest-quality CZT material. Dislocations and dislocation walls are the primary defects responsible for variations in charge carrier losses as they drift from the interaction points toward the charge-collecting electrodes. The mechanism by which these defects affect carrier transport is generally well understood. Dislocations and sub-grain boundaries act as sinks for carrier-trapping centers, primarily impurities and secondary phases such as tellurium inclusions and precipitates. Here, these regions exhibit significantly higher carrier-trapping rates, leading to variations in the μτ-products. Because the locations of these micron-sized regions are fixed within the detector volume, fluctuations in the total collected charge arise from the random distribution of interaction sites. This results in non-uniform detector responses and degradation of energy resolution. However, by measuring the interaction-site locations with sufficient precision, charge-loss variations can be accurately corrected, allowing recovery of nearly intrinsic energy resolution.

47 OTHER INSTRUMENTATION↗

Scintillation properties of diamond powders and feasibility of using them in thermal neutron detectors

Diamond offers unique properties for radiation detection, including high radiation hardness, very low gamma sensitivity, and fast response. Conventional diamond detectors rely on charge collection, but this approach requires ultra-pure single crystals and suffers from radiation-induced degradation. Here, in this work, we demonstrate an alternative approach using diamonds as scintillators for detection of charged particles and thermal neutrons. Prototypes were fabricated from commercially available diamond powders bonded to glass substrates and coupled with 6 LiF converters and silicon photomultipliers (SiPMs) and conventional PMTs. We characterized their scintillation properties under alpha particle excitation, x-ray photoluminescence, and thermal neutrons. The tryout detectors exhibit strong scintillation light signals, nanosecond-scale response times, and neutron detection efficiencies up to approximately 14 %, evaluated by comparison to conventional 3 He detector with known efficiency. These results demonstrate the feasibility of cost-effective, lightweight and robust diamond scintillation detectors for applications in space and planetary science, nuclear security, safeguards and environmental monitoring requiring efficient, robust, gamma-blind neutron detectors.

47 OTHER INSTRUMENTATION↗

Charge collection efficiency of diamond and silicon sensors irradiated with alpha particles

To evaluate the viability of using semiconductors as sensor materials in a detector for the Associated Particle Imaging technique, the radiation hardness of silicon and diamond diodes to alpha particles has been assessed. Here, the detector lifetimes for both silicon and diamond sensors were measured under the prolonged exposure to alpha particles emitted by an 241 Am source. The silicon detector was exposed to alpha radiation for approximately two months, reaching an accumulated fluence of ~ 1.5 x 10 12 α cm –2 . Additionally, by using a high purity single-crystal diamond with coplanar electrodes operating with full charge collection, the diamond detector response was measured over approximately ten months reaching an accumulated fluence of over 6 x 10 12 α cm –2 cm.

47 OTHER INSTRUMENTATION↗

Direct WIMP detection rates for transitions in isomeric nuclei

The direct detection of dark matter constituents, in particular the weakly interacting massive particles (WIMPs), is central to particle physics and cosmology. In this paper we study WIMP induced transitions from isomeric nuclear states for two possible isomeric candidates: 180 Ta and 166 Ho. The experimental setup, which can measure the possible decay of 180 Ta induced by WIMPs, was proposed. The corresponding estimates of the half-life of 180 Ta are given in the sense that the WIMP-nucleon interaction can be interpreted as ordinary radioactive decay.

47 OTHER INSTRUMENTATION↗

Hong-Ou-Mandel interference with a coexisting clock using transceivers for synchronization over deployed fiber

Interference between independently generated photons is a key step towards distributing entanglement over long distances, but it requires synchronization between the distantly-located photon sources. Synchronizing the clocks of such photon sources using coexisting two-way classical optical communications over the same fiber that transports the quantum photonic signals is a promising approach for achieving photon-photon interference over long distances, enabling entanglement distribution for quantum networking using the deployed fiber infrastructure. Here, we demonstrate photon-photon interference by observing the Hong-Ou-Mandel dip between two distantly-located sources: a weak coherent-state source obtained by attenuating the output of a laser and a heralded single-photon source. We achieve a maximum dip visibility of 0.58 +/- 0.04 when the two sources are connected via 4.3 km of deployed fiber. Dip visibilities > 0.5 are nonclassical and a first step towards achieving teleportation over the deployed fiber infrastructure. In our experiment, the classical optical communication is achieved with - 21 dBm of optical signal launch power, which is used to synchronize the clocks in the two independent, distantly-located photon sources. The impact of spontaneous Raman scattering from the classical optical signals is mitigated by appropriate choice of the quantum- and classical-channel wavelengths. All equipment used in our experiment (the photon sources and the synchronization setup) is commercially available. Finally, our experiment represents a scalable approach to enabling practical quantum networking with commercial equipment and coexistence with classical communications in optical fiber.

47 OTHER INSTRUMENTATION↗

Reproducible emission from nonlinear random lasers

Multiple scattering of light serves as a mechanism for feedback in random lasers. Consequently, internal spatial mode patterns, lasing wavelengths, and output directionality can all be random. Strong mode interaction can occur in such devices due to spatially overlapping modes resulting in nonlinearity with respect to the pump input power. Nevertheless, temporal coherence and lasing mode amplitude can be fixed at a constant pumping rate. This is a property desirable for applications where unique randomness is exploited but expected to be reliable over time, such as physical unclonable functions. Random lasers can also be cheaply and easily fabricated, exhibit relatively low lasing thresholds and high emission intensity. However, the precise scattering properties of such structures and fluctuations in the pump field can make device emission irreproducible, thereby limiting random laser applications. Here, in this work, we directly compare the random lasing spectra from zinc oxide samples fabricated in four distinct ways: spin-coating, sputtering, solgel deposition, and atomic layer deposition. The particular method of fabrication has a strong impact. Samples made through atomic layer deposition here exhibit both reproducibility and strong nonlinearity desirable for applications. Randomness in emission spectra persists across hundreds of repeated and averaged measurements irrespective of spatial location and is demonstrably nonlinear with respect to input signal intensity.

47 OTHER INSTRUMENTATION↗

Collimated phase measuring deflectometry II: Re-design of the optical layout for high-curvature surfaces

Collimated phase measuring deflectometry (CPMD) is an optical metrology technique developed to improve upon traditional phase measuring deflectometry (PMD). CPMD utilizes telecentric imaging and collimated structured light illumination to eliminate the height-slope ambiguity present in traditional PMD measurements. After the publication of the first CPMD paper, efforts began to optimize the optical layout of the CPMD system. The first proposed change, and the one detailed in this work, was to move the Fourier transform (FT) lens closer to the surface under test (SUT). Moving the FT lens closer to the SUT meant that for a given FT lens diameter, a larger range of surface slopes on the SUT could be measured. This change to the optical layout was not trivial and introduced at least two concerns that had to be addressed: telecentricity in the imaging path and possible ghost reflections from the re-located FT lens. Here, in this work, we examine how these concerns were addressed and present results showing that the revised optical layout is capable of measurement results at least as good as the original CPMD optical layout. We also demonstrate the increased slope measuring range of the revised optical layout.

47 OTHER INSTRUMENTATION↗

A full-scope, high-fidelity simulator-based hardware-in-the-loop testbed for comprehensive nuclear power plant cybersecurity research

Nuclear power plant (NPP) cybersecurity research often relies on hardware-in-the-loop (HIL) testbeds that integrate real hardware components into simulated environments. These testbeds allow researchers to identify vulnerabilities, evaluate attack impacts, and test security measures in a controlled setting. Furthermore, previous HIL testbeds lacked fidelity to accurately represent real nuclear systems, limiting the scope of cybersecurity analysis. This study presents the creation of a HIL testbed, devised upon a full-scope, high-fidelity NPP simulator, to facilitate realistic and comprehensive cybersecurity research. To demonstrate its capabilities, the control logic for the steam generator water level was migrated from the simulator to an external programmable logic controller. As a practical application of the developed testbed, supply chain attack scenarios were simulated by injecting malicious code into the controller logic, and the effects of manipulating sensor inputs and control commands were observed. While this HIL testbed provides more detailed simulations, enhanced realism, and wider applicability compared to other options utilizing a less complex simulator, it is also more intricate and costly. For this reason, we include a detailed comparison with some alternative architectures to aid fellow researchers and practitioners in the selection of a suitable HIL architecture based on specific research objectives.

47 OTHER INSTRUMENTATION↗

Photon counting with intensified charge coupled device (ICCD) – II. Laser induced breakdown spectroscopy (LIBS) spectral measurement

This study explores the application of photon counting (PC) to enhance the resolution of spectra acquired by an intensified charge-coupled device (ICCD) detector, with a focus on analytical atomic emission spectrometry using laser-induced breakdown spectroscopy (LIBS) as a use-case example. It demonstrates that, for spectra obtained with the same spectrometer–ICCD system, PC provides higher spectral resolution compared to conventional analog detector readout. This enhancement is particularly evident in the line wings of spectral peaks, facilitating better discrimination of isotopic peaks in the measured spectra. Although PC does not improve the resolution of an optical spectrometer directly, it rectifies the resolution lost caused by signal spreading in conventional ICCD analog measurement. However, similar to other counting techniques, excessive photons compromise detector linearity due to signal pileup. A correction model is proposed to mitigate the pileup effect, resulting in improved linearity and dynamic range in PC measurements. Additionally, the study reveals unexpected periodic structures in the flatfield image of the ICCD, which cause non-uniform detector gain in conventional analog as well as PC measurement modes and must be addressed for high-precision measurements.

47 OTHER INSTRUMENTATION↗