Search NASA⌕ Search

SEARCH · Search NASA

Results for “Active Flow Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Creep cavitation bands control porosity and fluid flow in lower crustal shear zones

Shear zones channelize fluid flow in Earth’s crust. However, little is known about deep crustal fluid migration and how fluids are channelized and distributed in a deforming lower crustal shear zone. This study investigates the deformation mechanisms, fluid-rock interaction, and development of porosity in a monzonite ultramylonite from Lofoten, northern Norway. The rock was deformed and transformed into an ultramylonite under lower crustal conditions (temperature = 700–730 °C, pressure = 0.65–0.8 GPa). The ultramylonite consists of feldspathic layers and domains of amphibole + quartz + calcite, which result from hydration reactions of magmatic clinopyroxene. The average grain size in both domains is <25 mm. Microstructural observations and electron backscatter diffraction analysis are consistent with diffusion creep as the dominant deformation mechanism in both domains. Festoons of isolated quartz grains define C'-type bands in feldspathic layers. These quartz grains do not show a crystallographic preferred orientation. The alignment of quartz grains is parallel to the preferred elongation of pores in the ultramylonites, as evidenced from synchrotron X-ray microtomography. Such C'-type bands are interpreted as creep cavitation bands resulting from diffusion creep deformation associated with grain boundary sliding. Mass-balance calculation indicates a 2% volume increase during the protolith-ultramylonite transformation, which is consistent with synkinematic formation of creep cavities producing dilatancy. Thus, this study presents evidence that creep cavitation bands may control deep crustal porosity and fluid flow. Nucleation of new phases in creep cavitation bands inhibits grain growth and enhances the activity of grain size–sensitive creep, thereby stabilizing strain localization in the polymineralic ultramylonites.

CENTRAL ALPS↗

Heat exchanger temperature response for duty-cycle transients in the NGNP/HTE.

Control system studies were performed for the Next Generation Nuclear Plant (NGNP) interfaced to the High Temperature Electrolysis (HTE) plant. Temperature change and associated thermal stresses are important factors in determining plant lifetime. In the NGNP the design objective of a 40 year lifetime for the Intermediate Heat Exchanger (IHX) in particular is seen as a challenge. A control system was designed to minimize temperature changes in the IHX and more generally at all high-temperature locations in the plant for duty-cycle transients. In the NGNP this includes structures at the reactor outlet and at the inlet to the turbine. This problem was approached by identifying those high-level factors that determine temperature rates of change. First are the set of duty cycle transients over which the control engineer has little control but which none-the-less must be addressed. Second is the partitioning of the temperature response into a quasi-static component and a transient component. These two components are largely independent of each other and when addressed as such greater understanding of temperature change mechanisms and how to deal with them is achieved. Third is the manner in which energy and mass flow rates are managed. Generally one aims for a temperature distribution that minimizes spatial non-uniformity of thermal expansion in a component with time. This is can be achieved by maintaining a fixed spatial temperature distribution in a component during transients. A general rule of thumb for heat exchangers is to maintain flow rate proportional to thermal power. Additionally the product of instantaneous flow rate and heat capacity should be maintained the same on both sides of the heat exchanger. Fourth inherent mechanisms for stable behavior should not be compromised by active controllers that can introduce new feedback paths and potentially create under-damped response. Applications of these principles to the development of a plant control strategy for the reference NGNP/HTE plant can be found in the body of this report. The outcome is an integrated plant/control system design. The following conclusions are drawn from the analysis: (1) The plant load schedule can be managed to maintain near-constant hot side temperatures over the load range in both the nuclear and chemical plant. (2) The reactor open-loop response is inherently stable resulting mainly from a large Doppler temperature coefficient compared to the other reactivity temperature feedbacks. (3) The typical controller used to manage reactor power production to maintain reactor outlet temperature at a setpoint introduces a feedback path that tends to destabilize reactor power production in the NGNP. (4) A primary loop flow controller that forces primary flow to track PCU flow rate is effective in minimizing spatial temperature differentials within the IHX. (5) Inventory control in both the primary and PCU system during ramp load change transients is an effective means of maintaining high NGNP thermal efficiency while at reduced electric load. (6) Turbine bypass control is an effective means for responding to step changes in generator load when equipment capacity limitations prevent inventory control from being effective. (7) Turbine bypass control is effective in limiting PCU shaft over speed for the loss of generator load upset event. (8) The proposed control strategy is effective in limiting time variation of the differential spatial temperature distribution in the IHX during transients. Essentially the IHX can be made to behave in a manner where each point in the IHX experiences approximately the same temperature rate of change during a transient. (9) The stability of the closed-loop Brayton cycle was found to be sensitive to where one operates on the turbo-machine performance maps. There are competing interests: more stable operation means operating on the curves at points that reduce overall cycle efficiency. Future work should address in greater detail elements that came to light in the course of this work. Specifically: (1) A stability analysis should be performed to identify the phenomena that control reactor outlet temperature stability when operating with the Reactor Outlet Temperature Controller. The goal is to identify a better performing controller. (2) Future simulations should be performed with multiple axial nodes. The single axial node model for the core used in this work gives rise to an initial core reactor outlet temperature perturbation that is a numerical artifact. (3) The tradeoffs referred to above regarding the dependence of Brayton cycle stability and efficiency on performance curve characteristics and use need to be better understood. (4) The role of xenon was neglected in this work and needs to be included in future work.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Restricting electron flow at cytochrome b6f when downstream electron acceptors are severely limited

Abstract Photosynthetic organisms frequently experience abiotic stress that restricts their growth and development. Under such circumstances, most absorbed solar energy cannot be used for CO2 fixation and can cause the photoproduction of reactive oxygen species (ROS) that can damage the photosynthetic reaction centers of PSI and PSII, resulting in a decline in primary productivity. This work describes a biological “switch” in the green alga Chlamydomonas reinhardtii that reversibly restricts photosynthetic electron transport (PET) at the cytochrome b6f (Cyt b6f) complex when the capacity for accepting electrons downstream of PSI is severely limited. We specifically show this restriction in STARCHLESS6 (sta6) mutant cells, which cannot synthesize starch when they are limited for nitrogen (growth inhibition) and subjected to a dark-to-light transition. This restriction represents a form of photosynthetic control that causes diminished electron flow to PSI and thereby prevents PSI photodamage but does not appear to rely on a ΔpH. Furthermore, when electron flow is restricted, the plastid alternative oxidase (PTOX) becomes active, functioning as an electron valve that dissipates some excitation energy absorbed by PSII and allows the formation of a proton motive force (PMF) that would drive some ATP production (potentially sustaining PSII repair and nonphotochemical quenching [NPQ]). The restriction at the Cyt b6f complex can be gradually relieved with continued illumination. This study provides insights into how PET responds to a marked reduction in availability of downstream electron acceptors and the protective mechanisms involved.

Plant Sciences↗

Rapid Quantification of 237 U Specific Activity for Nuclear Forensics

In the event of an unattributed nuclear explosion, rapid assessment of the short-lived uranium isotope activity and mass can provide valuable information for subsequent forensic analysis. Rapid analysis in the field is enabled by using microfluidic chemistry and deployable instrumentation. Here, this work presents a flow chemistry system, controlled in LabVIEW, that integrates three functionalities: (1) selective extraction of uranium from the sample matrix via a 3D-printed supported liquid membrane module; (2) UV–visible absorbance spectrophotometry to measure the total uranium concentration in the strip flow; and (3) a portable CdTe γ-ray spectrometer coupled to a 3D-printed flow cell to measure 237 U activity concentration in the strip solution. The system was calibrated using standard solutions, and its functionality was demonstrated using a solution of depleted uranium spiked with 237 U. Uranium concentrations of 40–5000 μg/mL were directly quantified online using a 100 mm optical flow cell, while concentrations of 0.5–10 μg/mL were quantified online using a colorimetric reagent. The mass concentration measurement takes approximately 60 min while the activity concentration via γ-ray spectrometry varies depending on the activity of 237 U, with 1 kBq/mL requiring about 30 min of acquisition time to obtain <10% uncertainty at 1σ. This platform provides a fieldable approach for quantifying uranium mass and radioactivity relevant to postdetonation nuclear debris.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Low frequency pulsed electromagnetic field promotes C2C12 myoblasts proliferation via activation of MAPK/ERK pathway

Low frequency pulsed electromagnetic field (PEMF) has been shown to affect the activity of various cell types and promote them proliferation. However, its effect on skeletal muscle cells remains to be determined. In our study, we confirmed that PEMF (100 Hz, 1 mT) could promote C2C12 myoblasts proliferation by using Cell Counting Kit-8 (CCK-8) and 5-Ethynyl-2’-deoxyuridine (EdU) assays, yet hardly any distinction was found in the rate of cell apoptosis between PEMF and control groups by flow cytometry (Annexin V-FITC/PI double staining method). To further study the mechanism of action of PEMF, Western blot was utilized to detect the mitogen-activated protein kinase (MAPK) signaling pathways. After exposing C2C12 myoblasts to PEMF, we found the phosphorylation level of extracellular signal-regulated kinase (ERK) was significantly increased, while p38 MAPK and c-Jun N-terminal kinase (JNK) pathways were not affected. Pretreating the cells with the ERK kinase1/2 (MEK1/2) inhibitor U0126 obviously inhibited the proliferation of C2C12 cells. Taken together, our research for the first time demonstrated that PEMF promoted C2C12 myoblasts proliferation via activating MAPK/ERK pathway.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Assessment of Thin Plastic Scintillation Detectors for Beta-Particle Measurements at the Advanced Test Reactor Critical Facility

The Fission Wire Measurement System is a custom measurement system designed in the 1960s to measure the beta-particle activity of irradiated uranium-aluminum fission wires. This measurement is conducted to determine the fission rate profile of the Advanced Reactor Test Critical facility. The Advanced Test Reactor Critical facility is an open-pool, low-power test reactor used to qualify experiment configurations and verify core models prior to full-power experiment irradiations in the Advanced Test Reactor. Power distribution measurements in ATR-C use uranium-aluminum wires that are distributed throughout the core to validate simulation and modeling results. These measurements require from 340 to 1500 wires to be irradiated and measured within a 12-hour window. The system consists of 4 measurement channels and one reference channel, each with a 2-pi proportional gas flow detector and the measurement channels each have an automated sample changer. The gas flow detectors are of a custom design for this detector system that use methane gas with a large anode wire compared to modern proportional counters. These detectors, which are nearly 60 years old are irreplaceable. The measurements from these gas detectors are affected by the gas flow rate, atmospheric and line pressure, and are very sensitive to the applied high voltage. Recent improvements have been made to the control and data acquisition system, but the detectors have remained the same. The nature of the measurement of the fission product decay activity is such that the energy spectrum of the signal is changing with time. Thin, 250-um thick, plastic scintillators were commercially obtained as a potential replacement for the gas flow detectors. The original calibration of the uranium-aluminum fission wires was conducted in 1965 using a series of irradiations of gold foils and the wires in a well-characterized thermal neutron field. These measurements provided a time-dependent fission rate conversion factor from the gold foil data to calibrate the fission wires based on the response from the 2-pi proportional gas detectors. Transitioning to the new detectors requires qualification and testing. The sensitivity of the scintillators to changes in the energy spectrum of the fission wires and translation of the calibration factor have been completed. These measurements indicated that the sensitivity of the scintillators over time changes at a different rate than the sensitivity of the gas flow detectors. However, the inverse activity of measurements of both detector types is linear with time. Initial results indicate that the scintillator detectors will be a sufficient replacement for the gas detectors with minor adjustments to the fission rate conversion factor. Replacement of the detectors will improve the fission wire measurements and provide a more stable and reliable measurement system.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Analysis and Control of a Three-Port Converter with High-Frequency AC Link for Hybrid Unmanned/Autonomous Aerial Vehicles

In this study, a three-port resonant converter with a high-frequency isolation link for hybrid unmanned/autonomous aerial vehicle (UAV/AAV) applications is analyzed. The rectified engine-generator set output supplies the first input ports while the other is connected to a battery energy storage system. Input ports consist of half-bridge high-frequency inverters, whereas output port utilizes a semi-bridgeless active rectifier. This rectifier is formed by replacing rectifier low-side diodes with active switching devices. A phase-shift duty-cycle control is implemented for switching signals to regulate the power share and flow between ports. The proposed control system implemented achieves zero voltage switching (ZVS), reduces switching losses, and minimum current flow optimization ensures regulation in a wide range of output power. Compared to the existing bidirectional pulse width modulation (PWM) converters, the proposed system decreases the number of power conversion stages and provides centralized control without needing communications between the ports. The proposed control technique operating in closed-loop control achieves the power flow between ports under various load conditions. Finally, theoretical analysis demonstrates the proposed converter’s viability and laboratory experimental validations at 500 W full power.

33 ADVANCED PROPULSION SYSTEMS↗

System and method for monitoring and controlling stator winding temperature in a de-energized AC motor

A system and method for measuring and controlling stator winding temperature in an AC motor while idling is disclosed. The system includes a circuit having an input connectable to an AC source and an output connectable to an input terminal of a multi-phase AC motor. The circuit further includes a plurality of switching devices to control current flow and terminal voltages in the multi-phase AC motor and a controller connected to the circuit. The controller is configured to activate the plurality of switching devices to create a DC signal in an output of the motor control device corresponding to an input to the multi-phase AC motor, determine or estimate a stator winding resistance of the multi-phase AC motor based on the DC signal, and estimate a stator temperature from the stator winding resistance. Temperature can then be controlled and regulated by DC injection into the stator windings.

42 ENGINEERING↗

System for controlling apnea

An implanted stimulation device or air control device are activated by an external radar-like sensor for controlling apnea. The radar-like sensor senses the closure of the air flow cavity, and associated control circuitry signals (1) a stimulator to cause muscles to open the air passage way that is closing or closed or (2) an air control device to open the air passage way that is closing or closed.

47 OTHER INSTRUMENTATION↗

Evaluating large scale aqueous organic redox flow battery performance with a hybrid numerical and machine learning framework

Aqueous organic redox flow battery (AORFB) is a promising cost-competitive technology for large-scale energy storage. Among existing work, the dihydroxyphenazine (DHP)-based AORFB has demonstrated high energy density and low-capacity degradation in 10 cm$^2$ cells during lab tests. However, its commercial-scale performance in more complex environments remains unknown, posing a barrier to commercialization. To address this gap, this work presents a comprehensive performance evaluation of a 780 cm$^2$ DHP-based AORFB by combining a physics-based numerical model, machine learning (ML)-based surrogate models, and ML-derived sensitivity quantification. Specifically, we first select 12 key battery parameters that include 10 physicochemical and 2 operation quantities, then select 6 performance metrics that include energy efficiency (EE), discharging capacity, charging energy, and power losses due to concentration, activation, and ohmic over-potentials. With such selection, 12800 combinations of the 12 parameters are subsequently generated using the Latin Hypercube Sampling method. Such combinations, together with 38 pre-defined State of Charge, are then integrated to a validated AORFB model developed in COMSOL to compute the performance metrics. With both input parameters and performance metrics, 60 deep neural network (DNN) surrogate models are then trained to approximate the relationship between the 10 physicochemical quantities and 6 performance metrics at each flow rate and current density. Sensitivity scores are then calculated based on the DNN models. Two additional sensitivity analysis tools, i.e., MARS, and SHAP, are also used to cross-validate the sensitivity scores from the DNN. The results demonstrate that 1) the standard potential ranks first in controlling EE and charging energy, 2) the membrane conductivity is most critical for power loss and EE, and 3) specific area and reaction rate control activation power loss.

25 ENERGY STORAGE↗

Model predictive direct power control for active power decoupled single-phase quasi- Z -source inverter

In this study, the active power filter (APF) that consists of a half-bridge leg and an ac capacitor is integrated in the single-phase quasi-Z-source inverter (qZSI) in this paper to avoid the second harmonic power flowing into the dc side. The capacitor of APF buffers the second harmonic power of the load, and the ac capacitor allows highly pulsating ac voltage, so that the capacitances of both dc and ac sides can be small. A model predictive direct power control (DPC) is further proposed to achieve the purpose of this newtopology through predicting the capacitor voltage of APF at each sampling period and ensuring the APF power to track the second harmonic power of single-phase qZSI. Simulation and experimental results verify the model predictive DPC for the APF-integrated single-phase qZSI.

30 DIRECT ENERGY CONVERSION↗

Stabilization and control of persistent current magnets using variable inductance

Ultra-stable, tunable magnetic fields are desirable for a wide range of applications in medical imaging, electron microscopy, quantum science, and atomic physics. Superconducting magnets operated in persistent current mode, with device current flowing in a closed superconducting loop disconnected from a power source, are a common approach for applications with the most stringent requirements on temporal field stability. In this work, we present a method for active control of this persistent current by means of dynamic inductance change within the superconducting circuit. For a first realization of this general technique, we consider a variable superconducting inductor placed in series with the main magnet. The inductor acts as a dynamic flux storage device capable of transferring flux to or from the main magnet through inductance change. This allows for fine and fast adjustments of the persistent current without the use of thermal switches that limit the speed and accuracy of many present-day methods. With first experiments employing this technique, we demonstrate stabilization of a 1.95 T Nb–Ti round lens for electron microscopy against decay resulting from residual losses in the superconducting circuit, and more generally show flexibility for precise control over the magnitude and waveform of the persistent current.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Mechanical properties and deformation mechanisms of single crystal Mg micropillars subjected to high-strain-rate C-axis compression

Here, the mechanical properties and deformation mechanisms of single crystal magnesium under c-axis quasi-static and high-strain rate compressions are investigated through in situ scanning electron microscope (SEM) experiments and post-mortem transmission electron microscope (TEM) characterization. The findings revealed that ductility and high rates of hardening are preserved for pillars as large as 15 μm. Furthermore, rate effects result in a mild increase in flow stress with plastic deformations controlled primarily by the slip of type dislocations. Importantly and in contrast to other literature reports, plastic deformation occurs in the absence of twining. As the strain increases and plastic deformation exceeds about 4%, crystal rotation activates basal slip, <$\mathrm{a}$> type dislocations, resulting in a more rate independent flow stress. TEM observation on micropillars compressed at a strain rate of 250/s, revealed the activation of {${11}$$\bar{2}$$\bar{2}$} < $\bar{1}$$\bar{1}23$ > slip systems and high mobility of screw dislocations as major contributors to plastic strains in excess of 10% without fracture. These findings are relevant to the design of lightweight materials used in transportation systems, e.g., selection of material grain size. Moreover, the experimental data here reported provides the materials science community with a unique opportunity to validate discrete dislocation dynamics (DDD) formulations employed in multiscale design of materials.

36 MATERIALS SCIENCE↗

Optimal Energy Dispatch of Distributed PVs for the Next Generation of Distribution Management Systems

Advanced Distribution Management Systems (ADMS) are being widely adopted by electric utilities for managing and optimizing the operations of their distribution systems. Distributed photovoltaic (DPV) systems with smart inverters can be controlled to adjust active power and reactive power outputs, and they are envisioned to become a part of (centrally or distributed) controllable assets managed by the ADMS for optimizing grid operations. This paper proposes an optimal energy dispatch strategy controlling DPV systems for regulating distribution voltages and achieving conservation voltage reduction. A convex optimization model is proposed with the use of linearized power flow, and the gradient projection algorithm is used to solve the optimal active power and reactive power outputs of smart inverters. The proposed optimal energy dispatch is implemented using an open-source ADMS platform, and simulation results have demonstrated the effectiveness of the proposed approach on improving distribution grid operations.

42 ENGINEERING↗

Radiosensitization of Oropharyngeal Squamous Cell Carcinoma Cells by Human Papillomavirus 16 Oncoprotein E6*I

Purpose: Patients with oropharyngeal squamous cell carcinoma (OSCC) whose disease is associated with high-risk human papillomavirus (HPV) infection have a significantly better outcome than those with HPV-negative disease, but the reasons for the better outcome are not known. We postulated that they might relate to an ability of HPV proteins to confer a better response to radiotherapy, a commonly used treatment for OSCC. Methods and Materials: We stably expressed the specific splicing-derived isoforms, E6*I and E6*II, or the entire E6 open reading frame (E6total), which gives rise to both full length and E6*I isoforms, in OSCC cell lines. Radiation resistance was measured in clonogenicity assays, p53 activity was measured using transfected reporter genes, and flow cytometry was used to analyze cell cycle and apoptosis. Results: E6*I and E6total sensitized the OSCC cells to irradiation, E6*I giving the greatest degree of radiosensitization (approximately eightfold lower surviving cell fraction at 10 Gy), whereas E6*II had no effect. In contrast to radiosensitivity, E6*I was a weaker inhibitor than E6total of tumor suppressor p53 transactivator activity in the same cells. Flow cytometric analyses showed that irradiated E6*I expressing cells had a much higher G2M:G1 ratio than control cells, indicating that, after G2, cells were diverted from the cell cycle to programmed cell death. Conclusion: This study supports a role for E6*I in the enhanced responsiveness of HPV-positive oropharyngeal carcinomas to p53-independent radiation-induced death.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of Double-Output CLL Resonant Converter for All-Electric UAV Applications

This paper presents a double-output resonant converter with high-frequency isolation for unmanned aerial vehicle (UAV) applications. The proposed topology is developed by using a full-bridge resonant inverter and double-output half-bridge active rectifiers. For the control system, a phase-shifted pulse width modulation (PS-PWM) method is utilized to adjusts the power flow among the output rectifiers in a wide voltage range regulation with a central control. The theoretical analysis of the converter is explored using the system model under different load conditions with constant frequency. The proposed system is validated with experimental results using 60 V input source and generating 0 - 100 V in each output at a full power of 500 W with 96% maximum efficiency in the laboratory experimental setup.

Asa, Erdem↗

FY20 SAM Code Developments and Validations for Transient Safety Analysis of Advanced non-LWRs

The System Analysis Module (SAM) is under development at Argonne National Laboratory as a modern system-level modeling and simulation tool for advanced non-light water reactor safety analyses. It utilizes the object-oriented application framework MOOSE to leverage the modern software environment and advanced numerical methods. The capabilities of SAM are being extended to enable the transient modeling, analysis, and design of various advanced nuclear reactor systems. This report summarizes major progress in SAM code development, capability enhancements, demonstration, and validation to support transient safety analysis of advanced non-LWRs. Rapid developments continued in fiscal year 2020 (FY20) to support various needs of the advanced reactor community, especially the NRC and industry on the licensing safety analysis of advanced reactor designs. Significant code changes were made to provide various capability enhancements, bug fixes, and user friendliness improvements. Major code updates are summarized in Section 1, while four important enhancements are detailed in Sections 2-5, including a multi-dimension flow model; reactivity feedback and decay heat models; control and trip system modeling, and additional fluid and solid thermophysical property models. Code validation activities in FY20 include using test data from the Fast Flux Test Facility (FFTF), the High Temperature Test Facility (HTTF), and several separate effects test facilities for pebble-bed modeling.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Data-Driven Wind Farm Optimization Incorporating Effects of Turbulence Intensity

We demonstrate assimilation of field data from a nacelle-mounted lidar and meteorological tower into a medium-fidelity Reynolds-Averaged Navier Stokes wind farm flow model to better predict the effects of atmospheric stability. Increased predictability under a variety of atmospheric conditions can lead to more effective control design and optimization of a wind farm. In particular, atmospheric stability affects wind turbine wake propagation and, therefore, aspects of wind farm control and performance, such as active wind farm control, layout optimization, and power output. Accurately modeling wakes in different stability conditions remains a persistent challenge. This paper presents an optimization framework that leverages high-fidelity field or simulation data to correct a lower-fidelity flow model. Optimal model corrections are found by solving a regularized, high-dimensional, gradient-based optimization problem using adjoint flowfield information. We validate the trained model against large eddy simulation results, and perform separate gradient-based layout optimizations of a simulated utility-scale wind farm to maximize power. Using the data-driven model corrections, we find that atmospheric stability significantly impacts layout optimization and power production: the optimal layout for stable conditions produced 9.1% more power than the optimal layout for unstable conditions, and the optimal layout for neutral conditions underperformed by 8.5% in unstable conditions.

17 WIND ENERGY↗