Search NASA⌕ Search

SEARCH · Search NASA

Results for “Active Thermal Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

International Space Station Acoustics – A Status Report

It is important to control acoustic noise aboard the International Space Station (ISS) to provide a satisfactory environment for voice communications, alarm audibility, and restful sleep, and to minimize the risk for hearing loss. Acoustic monitoring is an important part of the noise control process on ISS, providing critical data for trend analysis, noise exposure analysis, validation of acoustic analyses and predictions, and to provide strong evidence for ensuring crew health and safety, thus allowing Flight Certification. And since the primary noise sources on ISS include the environmental control and life support system’s air revitalization system (fans and airflow) and active thermal control system (pumps and water flow), acoustic monitoring will indicate changes in hardware noise emissions that may indicate system degradation or performance issues. This paper provides the current acoustic levels in the ISS modules and sleep stations, and is an update to the status presented in 2018. Since this last status report, noise levels have remained consistent, but issues with stalled fan noise and unexplained low frequency spectral peaks have caused some exceedances to requirements. Noise levels in the Russian Segment have either remained consistent or have been reduced slightly, except for the new Multipurpose Laboratory Module, which has some significant noise exceedances.

Christopher S Allen↗

Effect of cycling and thermal control on the storage and dynamics of a 40-L monolithic adsorbed natural gas tank

Adsorbed natural gas systems have been proposed as a cost-effective storage alternative to compressed and liquefied natural gas. This has led many groups to search and design sorbent materials with large methane storage capacities since natural gas is approximately 90% methane. The other 10% of natural gas contains larger hydrocarbons which can decrease the useable storage capacity of adsorbent systems. In this work, the effect of large hydrocarbons on the storage and dynamics of a 40-L adsorbed natural gas system, containing 20.5 kg of monolithic carbon adsorbent, produced by the University of Missouri, is reported. It was found that over the course of 20 cycles, due to the retention of 1.9 kg of non-methane components by the monoliths, the useable volumetric storage dropped 16%, and the amount of gas delivered dropped 10%. A second cycling experiment found that by using thermal control while the system discharged, the mass retention decreased to 0.91 kg, and the useable volumetric storage and delivered mass only dropped 7% and 5%, respectively. The effects of the mass retention, storage loss, and thermal control on the system’s charge and discharge dynamics were then analyzed to provide a complete picture of the long-term effects of cycling large scale adsorbed natural gas systems with and without active thermal control.

03 NATURAL GAS↗

Modeling a Packed Bed Reactor Utilizing the Sabatier Process

A numerical model is being developed using Python which characterizes the conversion and temperature profiles of a packed bed reactor (PBR) that utilizes the Sabatier process; the reaction produces methane and water from carbon dioxide and hydrogen. While the specific kinetics of the Sabatier reaction on the RuAl2O3 catalyst pellets are unknown, an empirical reaction rate equation1 is used for the overall reaction. As this reaction is highly exothermic, proper thermal control is of the utmost importance to ensure maximum conversion and to avoid reactor runaway. It is therefore necessary to determine what wall temperature profile will ensure safe and efficient operation of the reactor. This wall temperature will be maintained by active thermal controls on the outer surface of the reactor. Two cylindrical PBRs are currently being tested experimentally and will be used for validation of the Python model. They are similar in design except one of them is larger and incorporates a preheat loop by feeding the reactant gas through a pipe along the center of the catalyst bed. The further complexity of adding a preheat pipe to the model to mimic the larger reactor is yet to be implemented and validated; preliminary validation is done using the smaller PBR with no reactant preheating. When mapping experimental values of the wall temperature from the smaller PBR into the Python model, a good approximation of the total conversion and temperature profile has been achieved. A separate CFD model incorporates more complex three-dimensional effects by including the solid catalyst pellets within the domain. The goal is to improve the Python model to the point where the results of other reactor geometry can be reasonably predicted relatively quickly when compared to the much more computationally expensive CFD approach. Once a reactor size is narrowed down using the Python approach, CFD will be used to generate a more thorough prediction of the reactors performance.

Reactor↗

A computer aided engineering tool for ECLS systems

The Computer-Aided Systems Engineering and Analysis tool used by NASA for environmental control and life support system design studies is capable of simulating atmospheric revitalization systems, water recovery and management systems, and single-phase active thermal control systems. The designer/analysis interface used is graphics-based, and allows the designer to build a model by constructing a schematic of the system under consideration. Data management functions are performed, and the program is translated into a format that is compatible with the solution routines.

Bangham, Michal E.↗

Modeling a Transient Pressurization with Active Cooling Sizing Tool

As interest in the area of in-space zero boil-off cryogenic propellant storage develops, the need to visualize and quantify cryogen behavior during ventless tank self-pressurization and subsequent cool-down with active thermal control has become apparent. During the course of a mission, such as the launch ascent phase, there are periods that power to the active cooling system will be unavailable. In addition, because it is not feasible to install vacuum jackets on large propellant tanks, as is typically done for in-space cryogenic applications for science payloads, instances like the launch ascent heating phase are important to study. Numerous efforts have been made to characterize cryogenic tank pressurization during ventless cryogen storage without active cooling, but few tools exist to model this behavior in a user-friendly environment for general use, and none exist that quantify the marginal active cooling system size needed for power down periods to manage tank pressure response once active cooling is resumed. This paper describes the Transient pressurization with Active Cooling Tool (TACT), which is based on a ventless three-lump homogeneous thermodynamic self-pressurization model1 coupled with an active cooling system estimator. TACT has been designed to estimate the pressurization of a heated but unvented cryogenic tank, assuming an unavailable power period followed by a given cryocooler heat removal rate. By receiving input data on the tank material and geometry, propellant initial conditions, and passive and transient heating rates, a pressurization and recovery profile can be found, which establishes the time needed to return to a designated pressure. This provides the ability to understand the effect that launch ascent and unpowered mission segments have on the size of an active cooling system. A sample of the trends found show that an active cooling system sized for twice the steady state heating rate would results in a reasonable time for tank pressure recovery with ZBO of a liquid oxygen propellant tank.

Guzik, Monica C.↗

Method for Deriving Telescope Specifications for Earth-Detecting Coronagraphs and Its Use in Prioritizing Technology Development Investments

Different potential exoplanet mission concepts require different enabling and enhancing technologies. Decisions regarding prioritizing the development of these technologies can be made using a Science-Driven Systems-Engineering framework. The white paper makes the following specific recommendations. (1) Any potential telescope/coronagraph combination should develop a wavefront stability error budget using the method described in this white paper. That error budget will inform discussions about what technology development will be needed to enable the mission. (2) Enhancing and enabling technologies requiring investment include: low noise reaction wheels or control moment gyros; micro-thruster technology; active vibration isolation; materials and design practice for making lightweight stiff structures and optical components; 200-hertz wavefront sensing and control; 500-hertz sub-picometer-precision edge sensor and position actuators; non-destructive process to quantify CTE (Coefficient of Thermal Expansion) homogeneity of 4-meter class mirrors to an uncertainty of plus or minus 1 parts per billion per degree Kelvin over a 100 by 100 sampling; laser gauge positional metrology system; and predictive active thermal control.

Space Mirror Technology↗

Columbus Payloads Flow Rate Anomalies

The Columbus Active Thermal Control System (ATCS) is the main thermal bus for the pressurized racks working inside the European laboratory. One of the ATCS goals is to provide proper water flow rate to each payload (P/L) by controlling actively the pressure drop across the common plenum distribution piping. Overall flow measurement performed by the Water Pump Assembly (WPA) is the only flow rate monitor available at system level and is not part of the feedback control system. At rack activation the flow rate provided by the system is derived on ground by computing the WPA flow increase. With this approach, several anomalies were raised during these 3 years on-orbit, with the indication of low flow rate conditions on the European racks FSL, BioLab, EDR and EPM. This paper reviews the system and P/Ls calibration approach, the anomalies occurred, the engineering evaluation on the measurement approach and the accuracy improvements proposed, the on-orbit test under evaluation with NASA and finally discusses possible short and long term solutions in case of anomaly confirmation.

Quaranta, Albino↗

Spacelab environmental control system

This paper describes the NASA/MSFC thermal control activities performed in support of the European design and development of the Spacelab environmental control system (ECS) and the integration of the ECS with experiments and with the Shuttle Orbiter. Thermal interfaces with the Orbiter are reviewed, including payload bay temperature profiles for the long module and pallet Spacelab configuration for the on-orbit mission phase. Thermal designs and predicted thermal performance are also reviewed for the module air cooling systems and specific experiment interfaces, such as the experiment dedicated heat exchanger and rack cooling.

Mitchell, K. L.↗

On-Orbit Engineering and Vehicle Integration Poster Presentation

One of the duties of the MER Managers is getting the consoles to review and sign Electronic Flight Notes (EFN) and Mission Action Requests (Chit) before they are due. Chits and EFNs and are accessible through the Mission Control Center - Houston (MCC-H) Gateway. Chits are the official means of documenting questions and answers, technical direction, real-time changes to Flight Rules (FR) and procedures, request for analysis, etc. between various consoles concerning on-orbit operations. EFNs are documents used by the Flight Control Team (FCT) to communicate precise details between console positions and manage real time changes to FR and Systems Operation Data File (SODF) procedures. On GMT 2013/345 the External Active Thermal Control System (EATCS) on the Columbus (COL) Moderate Temperature Loop (MTL) Interface Heat Exchanger (IFHX) shut down due to low temperatures. Over the next couple of days, the core temperature of COL MT IFHX dropped due to the failure of the Flow Control Valve (FCV). After the temperature drop was discovered, heaters were turned on to bring the temperatures back to nominal. After the incident occurred, a possible freeze threat was discovered that could have ruptured the heat exchanger. The COL MT IFHX rupturing would be considered a catastrophic failure and potentially result in a loss of the vehicle and/or the lives of the International Space Station (ISS) crew members

Heimerdinger, Madison↗

Thermally Driven Structure and Performance Evolution of Atomically Dispersed FeN 4 Sites for Oxygen Reduction

Abstract FeN 4 moieties embedded in partially graphitized carbon are the most efficient platinum group metal free active sites for the oxygen reduction reaction in acidic proton‐exchange membrane fuel cells. However, their formation mechanisms have remained elusive for decades because the Fe−N bond formation process always convolutes with uncontrolled carbonization and nitrogen doping during high‐temperature treatment. Here, we elucidate the FeN 4 site formation mechanisms through hosting Fe ions into a nitrogen‐doped carbon followed by a controlled thermal activation. Among the studied hosts, the ZIF‐8‐derived nitrogen‐doped carbon is an ideal model with well‐defined nitrogen doping and porosity. This approach is able to deconvolute Fe−N bond formation from complex carbonization and nitrogen doping, which correlates Fe−N bond properties with the activity and stability of FeN 4 sites as a function of the thermal activation temperature.

Li, Jiazhan↗

CO2 and humidity removal system for extended Shuttle missions - Equilibrium testing and performance analysis

In Shuttle orbiter cabins, lithium hydroxide (LiOH) canisters are currently planned to be used for CO2 adsorption and condensing heat exchangers for humidity control. In this paper a more effective CO2 and humidity removal method is proposed by replacing the LiOH component with HS-C adsorbent (a polyethylenimine coated acrylic ester), thus eliminating the low temperature constraints on the active thermal control system. Since the adsorption of CO2 and H2O are reversible, a double bed configuration operating cyclicly is planned to provide continuous atmospheric control. Apparatus and the experimental procedure to test the adsorption equilibrium are described and some of the indicative results, tabulated by computers, are presented with the help of exponential expressions and differential equations. By using a computer model of the Shuttle HS-C system, performance predictions are made.

Davis, S. H.↗

Testing of an Ammonia EVA Vent Tool for the International Space Station

When components of the International Space Station ammonia External Active Thermal Control System are replaced on-orbit, they must be vented immediately after removal from the system. Venting ensures that the component is not hard packed with liquid and thus does not pose a hazard. An extravehicular activity (EVA) vent tool has been developed to perform this function. However, there were concerns that the tool could whip, posing a hazard to the EVA astronaut, or would freeze. The ammonia vent tool was recently tested in a thermal/vacuum chamber to demonstrate that it would operate safely and would not freeze during venting. During the test, ammonia mimicking the venting conditions for six different heat exchanger initial conditions was passed through representative test articles. In the present work, the model that was used to develop the ammonia state and flow for the test points is discussed and the test setup and operation is described. The qualitative whipping and freezing results of the test are discussed and vent plume pressure measurements are described and interpreted.

Ungar, Eugene K.↗

Enhanced Boiling on Micro-Configured Composite Surfaces Under Microgravity Conditions

In order to accommodate the growing thermal management needs of future space platforms, several two-phase active thermal control systems (ATCSs) have evolved and were included in the designs of space stations. Compared to the pumped single-phase liquid loops used in the conventional Space Transportation System and Spacelab, ATCSs offer significant benefits that may be realized by adopting a two-phase fluid-loop system. Alternately, dynamic power systems (DPSs), based on the Rankine cycle, seem inevitably to be required to supply the electrical power requirements of expanding space activities. Boiling heat transfer is one of the key technologies for both ATCSs and DPSs. Nucleate boiling near critical heat flux (CHF) can transport very large thermal loads with much smaller device size and much lower pumping power. However, boiling performance deteriorates in a reduced gravity environment and operation in the CHF regime is precarious because any slight overload will cause the heat transfer to suddenly move to the film boiling regime, which in turn, will result in burnout of the heat transfer surfaces. New materials, such as micro-configured metal-graphite composites, can provide a solution for boiling enhancement. It has been shown experimentally that this type of material manifests outstanding boiling heat transfer performance and their CHF is also extended to higher values. Due to the high thermal conductivity of graphite fiber (up to 1,200 W/m-K in the fiber direction), the composite surfaces are non-isothermal during the boiling process. The composite surfaces are believed to have a much wider safe operating region (a more uniform boiling curve in the CHF regime) because non-isothermal surfaces have been found to be less sensitive to variations of wall superheat in the CHF regime. The thermocapillary forces formed by the temperature difference between the fiber tips and the metal matrix play a more important role than the buoyancy in the bubble detachment, for the bubble detachment manifests itself by a necking process which should not be weakened by reduced gravity. In addition, the composite surfaces introduce no extra pressure drop, no fouling and do not impose significant primary or maintenance costs. All of these suggest that this type of composite is an ideal material for the challenge of accounting for both reliability and economy of the relevant components applied in the ATCSs, the DPSs and other devices in future space missions. The aim of the proposed work is to experimentally investigate high nucleate pool boiling performance on a micro-configured metal-graphite composite surface and to determine the mechanisms of the nucleate boiling heat transfer both experimentally and theoretically. Freon-113 and water will be used as the test liquids to investigate wettability effects on boiling characteristics. The Cu-Gr and Al-Gr composites with various volume fractions of graphite fibers will be tested to obtain the heat transfer characteristic data in the nucleate boiling region and in the CHF regime. In the experiments, the bubble emission and coalescence processes will be recorded by a video camera with a magnifying borescope probe immersed in the working fluid. The temperature profile in the thermal boundary layer on the composite surfaces will be measured by a group of micro thermocouples consisting of four ultra fine micro thermocouples. This instrument was developed and successfully used to measure the temperature profile of evaporating liquid thin layers by the proposers in a study performed at the NASA/Lewis Research Center. A two tier model to explain the nucleate boiling process and the performance enhancement on the composite surfaces has been suggested by the authors. According to the model, the thicknesses of the microlayer and the macrolayer underneath the bubbles and mushrooms, can be estimated by the geometry of the composite surface. The experimental results will be compared to the predictions from the model, and in turn, to revise and improve it.

Zhang, Nengli↗

High-Altitude Hydration System

Three methods are being developed for keeping water from freezing during high-altitude climbs so that mountaineers can remain hydrated. Three strategies have been developed. At the time of this reporting two needed to be tested in the field and one was conceptual. The first method is Passive Thermal Control Using Aerogels. This involves mounting the fluid reservoir of the climber s canteen to an inner layer of clothing for better heat retention. For the field test, bottles were mounted to the inner fleece layer of clothing, and then aerogel insulation was placed on the outside of the bottle, and circumferentially around the drink straw. When climbers need to drink, they can pull up the insulated straw from underneath the down suit, take a sip, and then put it back into the relative warmth of the suit. For the field test, a data logger assessed the temperatures of the water reservoir, as well as near the tip of the drink straw. The second method is Passive Thermal Control with Copper-Shielded Drink Straw and Aerogels, also mounted to inner layers of clothing for better heat retention. Braided wire emanates from the inside of the fleece jacket layer, and continues up and around the drink straw in order to use body heat to keep the system-critical drink straw warm enough to keep water in the liquid state. For the field test, a data logger will be used to compare this with the above concept. The third, and still conceptual, method is Active Thermal Control with Microcontroller. If the above methods do not work, microcontrollers and tape heaters have been identified that could keep the drink straw warm even under extremely cold conditions. Power requirements are not yet determined because the thermal environment inside the down suit relative to the external environment has not been established. A data logger will be used to track both the external and internal temperatures of the suit on a summit day.

Parazynski, Scott E.↗

On the Design and Test of a Liquid Injection Electric Thruster

A liquid injection electric thruster (LINJET) was designed and tested. The results of the tests were very encouraging with thruster performance levels well in excess of design goals. Supporting activities to the engine design and test included a five-million pulse life test on the main capacitor, a 46-million pulse test on the trigger electronics, design and fabrication of a zero resistance torque connector for use with the torsional pendulum thrust stand, design and fabrication of a logic box for control of engine firing, and a physical and chemical properties characterization of the perfluorocarbon propellant. While the results were encouraging, testing was limited, as many problems existed with the design. The most significant problem was involved with excessive propellant flow which contributed to false triggering and shorting. Low power active thermal control of the propellant storage cavity, coupled with a re-evaluation of the injection ring pore size and area exposed to the main capacitor discharge are areas that should be investigated should this design be carried forward.

Jones, T. A.↗

Spacecraft Radiator Freeze Protection Using a Regenerative Heat Exchanger with Bypass Setpoint Temperature Control

Spacecraft radiators are sized for their maximum heat load in their warmest thermal environment, but must operate at reduced heat loads and in colder environments. For systems where the radiator environment can be colder than the working fluid freezing temperature, radiator freezing becomes an issue. Radiator freezing has not been a major issue for the Space Shuttle and the International Space Station (ISS) active thermal control systems (ATCSs) because they operate in environments that are warm relative to the freezing point of their external coolants (Freon-21 and ammonia, respectively). For a vehicle that lands at the Lunar South Pole, the design thermal environment is 215K, but the radiator working fluid must also be kept from freezing during the 0 K sink of transit. A radiator bypass flow control design such as those used on the Space Shuttle and ISS requires more than 30% of the design heat load to avoid radiator freezing during transit - even with a very low freezing point working fluid. By changing the traditional ATCS architecture to include a regenerating heat exchanger inboard of the radiator and by using a regenerator bypass flow control valve to maintain system setpoint, the required minimum heat load can be reduced by more than half. This gives the spacecraft much more flexibility in design and operation. The present work describes the regenerator bypass ATCS setpoint control methodology. It includes analytical results comparing the performance of this system to the traditional radiator bypass system. Finally, a summary of the advantages of the regenerator bypass system are presented.

Ungar, Eugene K.↗

Integrated Modeling for the Next Generation Space Telescope "Yardstick" Concept

The so-called NASA "Yardstick" design concept for the Next Generation Space Telescope presents unique challenges for systems-level analysis. Simulations that integrate controls, optics, thermal, and structural models are required to evaluate baseline performance, study design sensitivities, and perform design optimization. An integrated modeling approach was chosen using a combination of commercial off-the-shelf and "in-house" developed codes. The resulting capability provides a foundation for linear and non-linear analysis, using both the time and frequency-domain methods. It readily allows various combinations of design parameters and environmental loads to be evaluated directly in terms of key science-related metrics, in this case the scalar RMS (root mean square) line-of-sight and RMS wavefront errors. This presentation first addresses the development of the component, or discipline, models for the Yardstick design. It will then proceed to present the integration of the component models, using linear-systems approaches, in order to support two of the most critical baseline performance analyses: jitter and thermal-elastic stability of the optical telescope assembly (OTA). The results of the jitter analysis indicate that disturbances from the reaction wheels coupled with the lightly-damped and highly-flexible structure present significant challenges to the baseline line-of-sight control architecture. Vibration isolation will be required to meet jitter error requirements. The results of the thermal-elastic analysis indicate that the mirror segment displacements due to ground-to-orbit cool-down of the telescope are within the expected capture range of the segment rigid-body control actuators. This means we will be able to align and phase the primary mirror. However, the results for the analysis of the thermal transient response following an attitude maneuver (slew) show that this telescope design is not sufficiently stable, passively, to meet the wavefront error requirements. Structural re-design is one possibility; alternatively, active thermal control of the OTA may be considered. The Yardstick integrated models were successfully used to demonstrate the feasibility of two thermal control strategies.

Mosier, Gary E.↗